CVE-2026-18585 (GCVE-0-2026-18585)

Vulnerability from cvelistv5 – Published: 2026-08-03 05:15 – Updated: 2026-08-03 13:21
VLAI
Title
GL.iNet MT2500 APPS-NAS nas-web.get_file_list heap-based overflow
Summary
A vulnerability was detected in GL.iNet MT3000, MT6000, BE9300, BE3600, MT3600BE, E5800, BE6500, MT5000, X3000, XE3000 and MT2500 up to 20260707. The affected element is the function nas-web.get_file_list of the component APPS-NAS Module. Performing a manipulation results in heap-based buffer overflow. The attack may be initiated remotely. The vendor was contacted early about this disclosure and confirmed the existence of the vulnerability.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-03 13:20 UTC
CWE
References
URL Tags
https://vuldb.com/vuln/385414 vdb-entrytechnical-description
https://vuldb.com/vuln/385414/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-18585 third-party-advisory
https://vuldb.com/submit/849290 third-party-advisory
https://github.com/gl-inet/CVE-issues/blob/main/4… related
Impacted products
Vendor Product Version CPE status
GL.iNet MT3000 Affected: 20260707
    cpe:2.3:a:gl.inet:mt3000:*:*:*:*:*:*:*:*
Create a notification for this product.
GL.iNet MT6000 Affected: 20260707
    cpe:2.3:a:gl.inet:mt6000:*:*:*:*:*:*:*:*
Create a notification for this product.
GL.iNet BE9300 Affected: 20260707
    cpe:2.3:a:gl.inet:be9300:*:*:*:*:*:*:*:*
Create a notification for this product.
GL.iNet BE3600 Affected: 20260707
    cpe:2.3:a:gl.inet:be3600:*:*:*:*:*:*:*:*
Create a notification for this product.
GL.iNet MT3600BE Affected: 20260707
    cpe:2.3:a:gl.inet:mt3600be:*:*:*:*:*:*:*:*
Create a notification for this product.
GL.iNet E5800 Affected: 20260707
    cpe:2.3:a:gl.inet:e5800:*:*:*:*:*:*:*:*
Create a notification for this product.
GL.iNet BE6500 Affected: 20260707
    cpe:2.3:a:gl.inet:be6500:*:*:*:*:*:*:*:*
Create a notification for this product.
GL.iNet MT5000 Affected: 20260707
    cpe:2.3:a:gl.inet:mt5000:*:*:*:*:*:*:*:*
Create a notification for this product.
GL.iNet X3000 Affected: 20260707
    cpe:2.3:a:gl.inet:x3000:*:*:*:*:*:*:*:*
Create a notification for this product.
GL.iNet XE3000 Affected: 20260707
    cpe:2.3:a:gl.inet:xe3000:*:*:*:*:*:*:*:*
Create a notification for this product.
GL.iNet MT2500 Affected: 20260707
    cpe:2.3:a:gl.inet:mt2500:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-18585",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-03T13:20:50.996638Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-03T13:21:10.843Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:gl.inet:mt3000:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "APPS-NAS Module"
          ],
          "product": "MT3000",
          "vendor": "GL.iNet",
          "versions": [
            {
              "status": "affected",
              "version": "20260707"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:gl.inet:mt6000:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "APPS-NAS Module"
          ],
          "product": "MT6000",
          "vendor": "GL.iNet",
          "versions": [
            {
              "status": "affected",
              "version": "20260707"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:gl.inet:be9300:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "APPS-NAS Module"
          ],
          "product": "BE9300",
          "vendor": "GL.iNet",
          "versions": [
            {
              "status": "affected",
              "version": "20260707"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:gl.inet:be3600:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "APPS-NAS Module"
          ],
          "product": "BE3600",
          "vendor": "GL.iNet",
          "versions": [
            {
              "status": "affected",
              "version": "20260707"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:gl.inet:mt3600be:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "APPS-NAS Module"
          ],
          "product": "MT3600BE",
          "vendor": "GL.iNet",
          "versions": [
            {
              "status": "affected",
              "version": "20260707"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:gl.inet:e5800:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "APPS-NAS Module"
          ],
          "product": "E5800",
          "vendor": "GL.iNet",
          "versions": [
            {
              "status": "affected",
              "version": "20260707"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:gl.inet:be6500:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "APPS-NAS Module"
          ],
          "product": "BE6500",
          "vendor": "GL.iNet",
          "versions": [
            {
              "status": "affected",
              "version": "20260707"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:gl.inet:mt5000:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "APPS-NAS Module"
          ],
          "product": "MT5000",
          "vendor": "GL.iNet",
          "versions": [
            {
              "status": "affected",
              "version": "20260707"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:gl.inet:x3000:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "APPS-NAS Module"
          ],
          "product": "X3000",
          "vendor": "GL.iNet",
          "versions": [
            {
              "status": "affected",
              "version": "20260707"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:gl.inet:xe3000:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "APPS-NAS Module"
          ],
          "product": "XE3000",
          "vendor": "GL.iNet",
          "versions": [
            {
              "status": "affected",
              "version": "20260707"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:gl.inet:mt2500:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "APPS-NAS Module"
          ],
          "product": "MT2500",
          "vendor": "GL.iNet",
          "versions": [
            {
              "status": "affected",
              "version": "20260707"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GLiNet (VulDB User)"
        },
        {
          "lang": "en",
          "type": "coordinator",
          "value": "VulDB CNA Team"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was detected in GL.iNet MT3000, MT6000, BE9300, BE3600, MT3600BE, E5800, BE6500, MT5000, X3000, XE3000 and MT2500 up to 20260707. The affected element is the function nas-web.get_file_list of the component APPS-NAS Module. Performing a manipulation results in heap-based buffer overflow. The attack may be initiated remotely. The vendor was contacted early about this disclosure and confirmed the existence of the vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P/E:ND/RL:ND/RC:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-03T05:15:07.982Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-385414 | GL.iNet MT2500 APPS-NAS nas-web.get_file_list heap-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/385414"
        },
        {
          "name": "VDB-385414 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/385414/cti"
        },
        {
          "name": "CVE-2026-18585 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-18585"
        },
        {
          "name": "Submit #849290 | GL.iNet Router 4.8.x Cache overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/849290"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/gl-inet/CVE-issues/blob/main/4.0.0/Heap%20buffer%20overflow%20in%20nas-web.get_file_list%20leading%20to%20authenticated%20denial%20of%20service.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-08-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-08-02T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-08-02T21:29:12.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "GL.iNet MT2500 APPS-NAS nas-web.get_file_list heap-based overflow",
      "x_generator": [
        "VulDB PVTS v202608"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-18585",
    "datePublished": "2026-08-03T05:15:07.982Z",
    "dateReserved": "2026-08-02T19:24:01.254Z",
    "dateUpdated": "2026-08-03T13:21:10.843Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-18585",
      "date": "2026-09-24",
      "epss": "0.00509",
      "percentile": "0.40873"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:a:gl.inet:mt3000:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "APPS-NAS Module"
                ],
                "product": "MT3000",
                "vendor": "GL.iNet",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20260707"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gl.inet:mt6000:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "APPS-NAS Module"
                ],
                "product": "MT6000",
                "vendor": "GL.iNet",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20260707"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gl.inet:be9300:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "APPS-NAS Module"
                ],
                "product": "BE9300",
                "vendor": "GL.iNet",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20260707"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gl.inet:be3600:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "APPS-NAS Module"
                ],
                "product": "BE3600",
                "vendor": "GL.iNet",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20260707"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gl.inet:mt3600be:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "APPS-NAS Module"
                ],
                "product": "MT3600BE",
                "vendor": "GL.iNet",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20260707"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gl.inet:e5800:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "APPS-NAS Module"
                ],
                "product": "E5800",
                "vendor": "GL.iNet",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20260707"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gl.inet:be6500:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "APPS-NAS Module"
                ],
                "product": "BE6500",
                "vendor": "GL.iNet",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20260707"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gl.inet:mt5000:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "APPS-NAS Module"
                ],
                "product": "MT5000",
                "vendor": "GL.iNet",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20260707"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gl.inet:x3000:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "APPS-NAS Module"
                ],
                "product": "X3000",
                "vendor": "GL.iNet",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20260707"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gl.inet:xe3000:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "APPS-NAS Module"
                ],
                "product": "XE3000",
                "vendor": "GL.iNet",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20260707"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gl.inet:mt2500:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "APPS-NAS Module"
                ],
                "product": "MT2500",
                "vendor": "GL.iNet",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20260707"
                  }
                ]
              }
            ],
            "source": "cna@vuldb.com"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability was detected in GL.iNet MT3000, MT6000, BE9300, BE3600, MT3600BE, E5800, BE6500, MT5000, X3000, XE3000 and MT2500 up to 20260707. The affected element is the function nas-web.get_file_list of the component APPS-NAS Module. Performing a manipulation results in heap-based buffer overflow. The attack may be initiated remotely. The vendor was contacted early about this disclosure and confirmed the existence of the vulnerability."
          }
        ],
        "id": "CVE-2026-18585",
        "lastModified": "2026-08-12T21:00:37.147",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.0,
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 1.4,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-18585",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-03T13:20:50.996638Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-08-03T06:16:37.710",
        "references": [
          {
            "source": "cna@vuldb.com",
            "url": "https://github.com/gl-inet/CVE-issues/blob/main/4.0.0/Heap%20buffer%20overflow%20in%20nas-web.get_file_list%20leading%20to%20authenticated%20denial%20of%20service.md"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/cve/CVE-2026-18585"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/submit/849290"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/vuln/385414"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/vuln/385414/cti"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              },
              {
                "lang": "en",
                "value": "CWE-122"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-18585",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-03T13:20:50.996638Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-03T13:20:58.229Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:a:gl.inet:mt3000:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "APPS-NAS Module"
              ],
              "product": "MT3000",
              "vendor": "GL.iNet",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260707"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:gl.inet:mt6000:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "APPS-NAS Module"
              ],
              "product": "MT6000",
              "vendor": "GL.iNet",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260707"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:gl.inet:be9300:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "APPS-NAS Module"
              ],
              "product": "BE9300",
              "vendor": "GL.iNet",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260707"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:gl.inet:be3600:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "APPS-NAS Module"
              ],
              "product": "BE3600",
              "vendor": "GL.iNet",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260707"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:gl.inet:mt3600be:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "APPS-NAS Module"
              ],
              "product": "MT3600BE",
              "vendor": "GL.iNet",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260707"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:gl.inet:e5800:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "APPS-NAS Module"
              ],
              "product": "E5800",
              "vendor": "GL.iNet",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260707"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:gl.inet:be6500:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "APPS-NAS Module"
              ],
              "product": "BE6500",
              "vendor": "GL.iNet",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260707"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:gl.inet:mt5000:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "APPS-NAS Module"
              ],
              "product": "MT5000",
              "vendor": "GL.iNet",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260707"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:gl.inet:x3000:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "APPS-NAS Module"
              ],
              "product": "X3000",
              "vendor": "GL.iNet",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260707"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:gl.inet:xe3000:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "APPS-NAS Module"
              ],
              "product": "XE3000",
              "vendor": "GL.iNet",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260707"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:gl.inet:mt2500:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "APPS-NAS Module"
              ],
              "product": "MT2500",
              "vendor": "GL.iNet",
              "versions": [
                {
                  "status": "affected",
                  "version": "20260707"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "GLiNet (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in GL.iNet MT3000, MT6000, BE9300, BE3600, MT3600BE, E5800, BE6500, MT5000, X3000, XE3000 and MT2500 up to 20260707. The affected element is the function nas-web.get_file_list of the component APPS-NAS Module. Performing a manipulation results in heap-based buffer overflow. The attack may be initiated remotely. The vendor was contacted early about this disclosure and confirmed the existence of the vulnerability."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 4,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P/E:ND/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-03T05:15:07.982Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-385414 | GL.iNet MT2500 APPS-NAS nas-web.get_file_list heap-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/385414"
            },
            {
              "name": "VDB-385414 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/385414/cti"
            },
            {
              "name": "CVE-2026-18585 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-18585"
            },
            {
              "name": "Submit #849290 | GL.iNet Router 4.8.x Cache overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/849290"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/gl-inet/CVE-issues/blob/main/4.0.0/Heap%20buffer%20overflow%20in%20nas-web.get_file_list%20leading%20to%20authenticated%20denial%20of%20service.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-02T21:29:12.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "GL.iNet MT2500 APPS-NAS nas-web.get_file_list heap-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-18585",
        "datePublished": "2026-08-03T05:15:07.982Z",
        "dateReserved": "2026-08-02T19:24:01.254Z",
        "dateUpdated": "2026-08-03T13:21:10.843Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…