CVE-2025-9064 (GCVE-0-2025-9064)
Vulnerability from cvelistv5 – Published: 2025-10-14 12:22 – Updated: 2025-10-14 18:46- CWE-287 - Improper Authentication
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Automation | FactoryTalk View Machine Edition |
Affected:
V15.00 and prior
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9064",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T18:46:24.670147Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T18:46:34.339Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk View Machine Edition",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "V15.00 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
}
],
"value": "A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T12:22:36.551Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cp\u003e-FactoryTalk View ME V15.00 and later on ASEM 6300 IPC\u2019s \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e-Patch \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1152571\"\u003eBF31001\u003c/a\u003e\u0026nbsp; \u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e-PanelView Plus 7 Performance Series B \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112\u0026amp;mode=3\u0026amp;refSoft=1\u0026amp;versions=61168\"\u003eV14.103\u003c/a\u003e firmware package \u0026nbsp;\u003c/p\u003e\u003c/div\u003e"
}
],
"value": "-FactoryTalk View ME V15.00 and later on ASEM 6300 IPC\u2019s \n\n\n\n-Patch BF31001 https://support.rockwellautomation.com/app/answers/answer_view/a_id/1152571 \u00a0 \u00a0\n\n\n\n\u00a0\n\n\n\n-PanelView Plus 7 Performance Series B V14.103 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx firmware package"
}
],
"source": {
"advisory": "SD1753",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation FactoryTalk View Machine Edition Path Traversal",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-9064",
"datePublished": "2025-10-14T12:22:36.551Z",
"dateReserved": "2025-08-15T13:56:26.986Z",
"dateUpdated": "2025-10-14T18:46:34.339Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-9064",
"date": "2026-06-06",
"epss": "0.00488",
"percentile": "0.65871"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2025-9064\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2025-10-14T13:15:39.643\",\"lastModified\":\"2025-10-28T15:20:33.767\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:machine:*:*:*\",\"versionEndIncluding\":\"15.0\",\"matchCriteriaId\":\"657BF325-6E3D-4E4F-971E-65B2300D3B13\"}]}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-9064\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-10-14T18:46:24.670147Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-10-14T18:46:29.486Z\"}}], \"cna\": {\"title\": \"Rockwell Automation FactoryTalk View Machine Edition Path Traversal\", \"source\": {\"advisory\": \"SD1753\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Rockwell Automation\", \"product\": \"FactoryTalk View Machine Edition\", \"versions\": [{\"status\": \"affected\", \"version\": \"V15.00 and prior\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"-FactoryTalk View ME V15.00 and later on ASEM 6300 IPC\\u2019s \\n\\n\\n\\n-Patch BF31001 https://support.rockwellautomation.com/app/answers/answer_view/a_id/1152571 \\u00a0 \\u00a0\\n\\n\\n\\n\\u00a0\\n\\n\\n\\n-PanelView Plus 7 Performance Series B V14.103 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx firmware package\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cdiv\u003e\u003cp\u003e-FactoryTalk View ME V15.00 and later on ASEM 6300 IPC\\u2019s \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e-Patch \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1152571\\\"\u003eBF31001\u003c/a\u003e\u0026nbsp; \u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e-PanelView Plus 7 Performance Series B \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112\u0026amp;mode=3\u0026amp;refSoft=1\u0026amp;versions=61168\\\"\u003eV14.103\u003c/a\u003e firmware package \u0026nbsp;\u003c/p\u003e\u003c/div\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eA path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.\u003c/span\u003e\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\u0026nbsp;\u003c/span\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-287\", \"description\": \"CWE-287: Improper Authentication\"}]}], \"providerMetadata\": {\"orgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"shortName\": \"Rockwell\", \"dateUpdated\": \"2025-10-14T12:22:36.551Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-9064\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-14T18:46:34.339Z\", \"dateReserved\": \"2025-08-15T13:56:26.986Z\", \"assignerOrgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"datePublished\": \"2025-10-14T12:22:36.551Z\", \"assignerShortName\": \"Rockwell\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"CVSS 4.0": "AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Rockwell Automation Inc.",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 15.00 (FactoryTalk View Machine Edition (ME))",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "14.10.2025",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "17.12.2025",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "17.12.2025",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2025-16039",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2025-9064",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u043d\u043e\u0433\u043e\u0444\u0430\u043a\u0442\u043e\u0440\u043d\u0430\u044f",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "FactoryTalk View Machine Edition (ME)",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0441\u043e\u0437\u0434\u0430\u043d\u0438\u044f \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0433\u0440\u0430\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u043e\u043c \u043e\u043f\u0435\u0440\u0430\u0442\u043e\u0440\u0430 (HMI) \u043d\u0430 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445 Rockwell Automation FactoryTalk View Machine Edition, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043d\u0435\u0432\u0435\u0440\u043d\u044b\u043c \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435\u043c \u0438\u043c\u0435\u043d\u0438 \u043f\u0443\u0442\u0438 \u043a \u043a\u0430\u0442\u0430\u043b\u043e\u0433\u0443 \u0441 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u043c \u0434\u043e\u0441\u0442\u0443\u043f\u043e\u043c, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u0432\u0435\u0440\u043d\u043e\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0438\u043c\u0435\u043d\u0438 \u043f\u0443\u0442\u0438 \u043a \u043a\u0430\u0442\u0430\u043b\u043e\u0433\u0443 \u0441 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u043c \u0434\u043e\u0441\u0442\u0443\u043f\u043e\u043c (\u00ab\u041e\u0431\u0445\u043e\u0434 \u043f\u0443\u0442\u0438\u00bb) (CWE-22), \u041d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u0430\u0443\u0442\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f (CWE-287)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0441\u043e\u0437\u0434\u0430\u043d\u0438\u044f \u0438 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f \u0433\u0440\u0430\u0444\u0438\u0447\u0435\u0441\u043a\u0438\u043c \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441\u043e\u043c \u043e\u043f\u0435\u0440\u0430\u0442\u043e\u0440\u0430 (HMI) \u043d\u0430 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u0445 Rockwell Automation FactoryTalk View Machine Edition \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u0432\u0435\u0440\u043d\u044b\u043c \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435\u043c \u0438\u043c\u0435\u043d\u0438 \u043f\u0443\u0442\u0438 \u043a \u043a\u0430\u0442\u0430\u043b\u043e\u0433\u0443 \u0441 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u043c \u0434\u043e\u0441\u0442\u0443\u043f\u043e\u043c. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u0430\u043c\u0438, \u041d\u0430\u0440\u0443\u0448\u0435\u043d\u0438\u0435 \u0430\u0443\u0442\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-22, CWE-287",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.1 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,5)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u043e\u0446\u0435\u043d\u043a\u0430 CVSS 4.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 8,7)"
}
厂商已发布了漏洞修复程序,请及时关注更新: https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html
| Name | Rockwell Automation FactoryTalk View Machine Edition <=V15.00 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2025-9064",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2025-9064"
}
},
"description": "Rockwell Automation FactoryTalk View Machine Edition\u662f\u7f8e\u56fd\u7f57\u514b\u97e6\u5c14\uff08Rockwell Automation\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u591a\u529f\u80fd\u4eba\u673a\u754c\u9762\u5e94\u7528\u7a0b\u5e8f\u3002\n\nRockwell Automation FactoryTalk View Machine Edition\u5b58\u5728\u8def\u5f84\u904d\u5386\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5220\u9664\u9762\u677f\u64cd\u4f5c\u7cfb\u7edf\u4e2d\u7684\u4efb\u4f55\u6587\u4ef6\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2026-10846",
"openTime": "2026-02-10",
"patchDescription": "Rockwell Automation FactoryTalk View Machine Edition\u662f\u7f8e\u56fd\u7f57\u514b\u97e6\u5c14\uff08Rockwell Automation\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u591a\u529f\u80fd\u4eba\u673a\u754c\u9762\u5e94\u7528\u7a0b\u5e8f\u3002\r\n\r\nRockwell Automation FactoryTalk View Machine Edition\u5b58\u5728\u8def\u5f84\u904d\u5386\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5220\u9664\u9762\u677f\u64cd\u4f5c\u7cfb\u7edf\u4e2d\u7684\u4efb\u4f55\u6587\u4ef6\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Rockwell Automation FactoryTalk View Machine Edition\u8def\u5f84\u904d\u5386\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Rockwell Automation FactoryTalk View Machine Edition \u003c=V15.00"
},
"referenceLink": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html",
"serverity": "\u9ad8",
"submitTime": "2025-10-17",
"title": "Rockwell Automation FactoryTalk View Machine Edition\u8def\u5f84\u904d\u5386\u6f0f\u6d1e"
}
FKIE_CVE-2025-9064
Vulnerability from fkie_nvd - Published: 2025-10-14 13:15 - Updated: 2025-10-28 15:20| Vendor | Product | Version | |
|---|---|---|---|
| rockwellautomation | factorytalk_view | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:machine:*:*:*",
"matchCriteriaId": "657BF325-6E3D-4E4F-971E-65B2300D3B13",
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted."
}
],
"id": "CVE-2025-9064",
"lastModified": "2025-10-28T15:20:33.767",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
]
},
"published": "2025-10-14T13:15:39.643",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-RP2M-9JH8-H55H
Vulnerability from github – Published: 2025-10-14 15:31 – Updated: 2025-10-28 15:30A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.
{
"affected": [],
"aliases": [
"CVE-2025-9064"
],
"database_specific": {
"cwe_ids": [
"CWE-22",
"CWE-287"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-10-14T13:15:39Z",
"severity": "HIGH"
},
"details": "A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.",
"id": "GHSA-rp2m-9jh8-h55h",
"modified": "2025-10-28T15:30:39Z",
"published": "2025-10-14T15:31:26Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-9064"
},
{
"type": "WEB",
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"type": "CVSS_V3"
},
{
"score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
ICSA-25-289-01
Vulnerability from csaf_cisa - Published: 2025-10-16 06:00 - Updated: 2025-10-16 06:00{
"document": {
"acknowledgments": [
{
"organization": "Rockwell Automation",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow an unauthenticated attacker to access to the device\u0027s file system.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "United States",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-25-289-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-289-01.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-25-289-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-289-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "Rockwell Automation FactoryTalk View Machine Edition and PanelView Plus 7",
"tracking": {
"current_release_date": "2025-10-16T06:00:00.000000Z",
"generator": {
"date": "2025-10-15T20:51:14.908736Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-289-01",
"initial_release_date": "2025-10-16T06:00:00.000000Z",
"revision_history": [
{
"date": "2025-10-16T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV15.00",
"product": {
"name": "Rockwell Automation FactoryTalk View Machine Edition: \u003cV15.00",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "FactoryTalk View Machine Edition"
},
{
"branches": [
{
"category": "product_version",
"name": "V14.100",
"product": {
"name": "Rockwell Automation PanelView Plus 7: V14.100",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "PanelView Plus 7"
}
],
"category": "vendor",
"name": "Rockwell Automation"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-9064",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-9064"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3-1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Rockwell Automation encourages users of the affected software to apply the following risk mitigations, if possible:",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For CVE-2025-9064, update FactoryTalk View ME V15.00 and later on ASEM 6300 IPC\u0027s-Patch BF31001.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.rockwellautomation.com/app/answers/answer_view/a_id/1152571"
},
{
"category": "vendor_fix",
"details": "For CVE-2025-9063 and CVE-2025-9064, update PanelView Plus 7 Performance Series B V14.103 firmware package.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112\u0026mode=3\u0026refSoft=1\u0026versions=61168"
},
{
"category": "mitigation",
"details": "Rockwell Automation encourages users of the affected software who are unable to upgrade to one of the corrected versions to follow Rockwell Automation\u0027s security best practices.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
},
{
"category": "mitigation",
"details": "For more information, visit Rockwell Automation Security Advisories for more information.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2025-9063",
"cwe": {
"id": "CWE-285",
"name": "Improper Authorization"
},
"notes": [
{
"category": "summary",
"text": "An authentication bypass security issue exists within FactoryTalk View Machine Edition Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-9063"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3-1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4-0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Rockwell Automation encourages users of the affected software to apply the following risk mitigations, if possible:",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "For CVE-2025-9063 and CVE-2025-9064, update PanelView Plus 7 Performance Series B V14.103 firmware package.",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112\u0026mode=3\u0026refSoft=1\u0026versions=61168"
},
{
"category": "mitigation",
"details": "Rockwell Automation encourages users of the affected software who are unable to upgrade to one of the corrected versions to follow Rockwell Automation\u0027s security best practices.",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
},
{
"category": "mitigation",
"details": "For more information, visit Rockwell Automation Security Advisories for more information.",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories.html"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0002"
]
}
]
}
]
}
NCSC-2025-0345
Vulnerability from csaf_ncscnl - Published: 2025-10-31 09:35 - Updated: 2025-10-31 09:35An authentication bypass vulnerability in FactoryTalk View Machine Edition's Web Browser ActiveX control allows unauthorized access to the PanelView Plus 7 Series B, compromising the file system and diagnostic information.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Rockwell Automation / FactoryTalk
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk Linx
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk View Machine Edition
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk ViewPoint
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / PanelView Plus 7 Performance B
|
vers:unknown/* |
A path traversal vulnerability in FactoryTalk View Machine Edition enables unauthenticated attackers on the same network to delete any file in the device's operating system if they know the specific filenames.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Rockwell Automation / FactoryTalk
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk Linx
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk View Machine Edition
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk ViewPoint
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / PanelView Plus 7 Performance B
|
vers:unknown/* |
A security vulnerability in FactoryTalk® ViewPoint allows unauthenticated attackers to exploit XXE via specific SOAP requests, resulting in a temporary denial-of-service.
CWE-20 - Improper Input Validation| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Rockwell Automation / FactoryTalk
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk Linx
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk View Machine Edition
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk ViewPoint
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / PanelView Plus 7 Performance B
|
vers:unknown/* |
A security vulnerability in the x86 Microsoft Installer File (MSI) used with FTLinx allows authenticated attackers to exploit a repair process, gaining SYSTEM-level access to the system.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Rockwell Automation / FactoryTalk
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk Linx
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk View Machine Edition
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk ViewPoint
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / PanelView Plus 7 Performance B
|
vers:unknown/* |
A security vulnerability in the Rockwell Automation Driver Package x64 MSI allows authenticated attackers to exploit the vbpinstall.exe console, gaining SYSTEM-level privileges and full access to system resources.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Rockwell Automation / FactoryTalk
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk Linx
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk View Machine Edition
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / FactoryTalk ViewPoint
|
vers:unknown/* | ||
|
vers:unknown/*
Rockwell Automation / PanelView Plus 7 Performance B
|
vers:unknown/* |
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE"
}
},
"lang": "nl",
"notes": [
{
"category": "legal_disclaimer",
"text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings."
},
{
"category": "description",
"text": "Rockwell Automation heeft kwetsbaarheden verholpen in FactoryTalk View Machine Edition.",
"title": "Feiten"
},
{
"category": "description",
"text": "De kwetsbaarheden omvatten een authenticatie-bypass die ongeautoriseerde toegang tot het bestandssysteem en diagnostische informatie van de PanelView Plus 7 Series B toestaat. Daarnaast is er een pad-traversal kwetsbaarheid die ongeauthenticeerde aanvallers in staat stelt om bestanden binnen het besturingssysteem van het apparaat te verwijderen. Verder is er een XML External Entity (XXE) kwetsbaarheid die kan leiden tot tijdelijke denial-of-service. Ook zijn er kwetsbaarheden in de Microsoft Installer File (MSI) die door geauthenticeerde aanvallers kunnen worden misbruikt om SYSTEM-niveau toegang te verkrijgen. Deze kwetsbaarheden kunnen leiden tot ernstige gevolgen, waaronder dataverlies, systeeminstabiliteit en ongeautoriseerde controle over systeembronnen.\n\nVoor succesvol misbruik moet de kwaadwillende toegang hebben tot de productieomgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.",
"title": "Interpretaties"
},
{
"category": "description",
"text": "Rockwell Automation heeft updates uitgebracht om de kwetsbaarheden te verhelpen. Zie bijgevoegde referenties voor meer informatie.",
"title": "Oplossingen"
},
{
"category": "general",
"text": "medium",
"title": "Kans"
},
{
"category": "general",
"text": "high",
"title": "Schade"
},
{
"category": "general",
"text": "Improper Input Validation",
"title": "CWE-20"
},
{
"category": "general",
"text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"title": "CWE-22"
},
{
"category": "general",
"text": "Improper Privilege Management",
"title": "CWE-269"
},
{
"category": "general",
"text": "Improper Authentication",
"title": "CWE-287"
},
{
"category": "general",
"text": "Improper Resource Shutdown or Release",
"title": "CWE-404"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "cert@ncsc.nl",
"name": "Nationaal Cyber Security Centrum",
"namespace": "https://www.ncsc.nl/"
},
"references": [
{
"category": "external",
"summary": "Reference",
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1752.html"
},
{
"category": "external",
"summary": "Reference",
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html"
},
{
"category": "external",
"summary": "Reference",
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1754.html"
}
],
"title": "Kwetsbaarheden verholpen in Rockwell Automation FactoryTalk",
"tracking": {
"current_release_date": "2025-10-31T09:35:00.469498Z",
"generator": {
"date": "2025-08-04T16:30:00Z",
"engine": {
"name": "V.A.",
"version": "1.3"
}
},
"id": "NCSC-2025-0345",
"initial_release_date": "2025-10-31T09:35:00.469498Z",
"revision_history": [
{
"date": "2025-10-31T09:35:00.469498Z",
"number": "1.0.0",
"summary": "Initiele versie"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-1"
}
}
],
"category": "product_name",
"name": "FactoryTalk"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-2"
}
}
],
"category": "product_name",
"name": "FactoryTalk Linx"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-3"
}
}
],
"category": "product_name",
"name": "FactoryTalk View Machine Edition"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-4"
}
}
],
"category": "product_name",
"name": "FactoryTalk ViewPoint"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-5"
}
}
],
"category": "product_name",
"name": "PanelView Plus 7 Performance B"
}
],
"category": "vendor",
"name": "Rockwell Automation"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-9063",
"cwe": {
"id": "CWE-287",
"name": "Improper Authentication"
},
"notes": [
{
"category": "other",
"text": "Improper Authentication",
"title": "CWE-287"
},
{
"category": "description",
"text": "An authentication bypass vulnerability in FactoryTalk View Machine Edition\u0027s Web Browser ActiveX control allows unauthorized access to the PanelView Plus 7 Series B, compromising the file system and diagnostic information.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-9063 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-9063.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5"
]
}
],
"title": "CVE-2025-9063"
},
{
"cve": "CVE-2025-9064",
"cwe": {
"id": "CWE-287",
"name": "Improper Authentication"
},
"notes": [
{
"category": "other",
"text": "Improper Authentication",
"title": "CWE-287"
},
{
"category": "other",
"text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"title": "CWE-22"
},
{
"category": "description",
"text": "A path traversal vulnerability in FactoryTalk View Machine Edition enables unauthenticated attackers on the same network to delete any file in the device\u0027s operating system if they know the specific filenames.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-9064 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-9064.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5"
]
}
],
"title": "CVE-2025-9064"
},
{
"cve": "CVE-2025-9066",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "other",
"text": "Improper Input Validation",
"title": "CWE-20"
},
{
"category": "description",
"text": "A security vulnerability in FactoryTalk\u00ae ViewPoint allows unauthenticated attackers to exploit XXE via specific SOAP requests, resulting in a temporary denial-of-service.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-9066 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-9066.json"
}
],
"title": "CVE-2025-9066"
},
{
"cve": "CVE-2025-9067",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "other",
"text": "Improper Privilege Management",
"title": "CWE-269"
},
{
"category": "description",
"text": "A security vulnerability in the x86 Microsoft Installer File (MSI) used with FTLinx allows authenticated attackers to exploit a repair process, gaining SYSTEM-level access to the system.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-9067 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-9067.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5"
]
}
],
"title": "CVE-2025-9067"
},
{
"cve": "CVE-2025-9068",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "other",
"text": "Improper Privilege Management",
"title": "CWE-269"
},
{
"category": "description",
"text": "A security vulnerability in the Rockwell Automation Driver Package x64 MSI allows authenticated attackers to exploit the vbpinstall.exe console, gaining SYSTEM-level privileges and full access to system resources.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-9068 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-9068.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5"
]
}
],
"title": "CVE-2025-9068"
}
]
}
WID-SEC-W-2025-2273
Vulnerability from csaf_certbund - Published: 2025-10-13 22:00 - Updated: 2025-10-14 22:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Rockwell Automation FactoryTalk View Machine PanelView Plus 7 Performance Series B <V14.103
Rockwell Automation / FactoryTalk
|
View Machine PanelView Plus 7 Performance Series B <V14.103 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Rockwell Automation FactoryTalk View Machine Edition <V15.00
Rockwell Automation / FactoryTalk
|
View Machine Edition <V15.00 | ||
|
Rockwell Automation FactoryTalk View Machine PanelView Plus 7 Performance Series B <V14.103
Rockwell Automation / FactoryTalk
|
View Machine PanelView Plus 7 Performance Series B <V14.103 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Rockwell Automation FactoryTalk ViewPoint Panel View Plus 7 Terminal <V14.103
Rockwell Automation / FactoryTalk
|
ViewPoint Panel View Plus 7 Terminal <V14.103 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Rockwell Automation FactoryTalk Linx <6.50
Rockwell Automation / FactoryTalk
|
Linx <6.50 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Rockwell Automation FactoryTalk Linx <6.50
Rockwell Automation / FactoryTalk
|
Linx <6.50 |
{
"document": {
"aggregate_severity": {
"text": "mittel"
},
"category": "csaf_base",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "de-DE",
"notes": [
{
"category": "legal_disclaimer",
"text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen."
},
{
"category": "description",
"text": "FactoryTalk ist eine Software f\u00fcr die industrielle Automatisierung, die zur Maximierung der Effizienz und Steigerung der Anlagenproduktivit\u00e4t entwickelt wurde.",
"title": "Produktbeschreibung"
},
{
"category": "summary",
"text": "Ein lokaler oder entfernter anonymer Angreifer kann mehrere Schwachstellen in Rockwell Automation FactoryTalk ausnutzen, um Administratorrechte zu erlangen, Sicherheitsma\u00dfnahmen zu umgehen oder einen Denial-of-Service-Zustand zu erzeugen.",
"title": "Angriff"
},
{
"category": "general",
"text": "- Sonstiges\n- UNIX",
"title": "Betroffene Betriebssysteme"
}
],
"publisher": {
"category": "other",
"contact_details": "csaf-provider@cert-bund.de",
"name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik",
"namespace": "https://www.bsi.bund.de"
},
"references": [
{
"category": "self",
"summary": "WID-SEC-W-2025-2273 - CSAF Version",
"url": "https://wid.cert-bund.de/.well-known/csaf/white/2025/wid-sec-w-2025-2273.json"
},
{
"category": "self",
"summary": "WID-SEC-2025-2273 - Portal Version",
"url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2025-2273"
},
{
"category": "external",
"summary": "Rockwell Security Advisory vom 2025-10-13",
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1752.html"
},
{
"category": "external",
"summary": "Rockwell Security Advisory vom 2025-10-13",
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html"
},
{
"category": "external",
"summary": "Rockwell Security Advisory vom 2025-10-13",
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1754.html"
}
],
"source_lang": "en-US",
"title": "Rockwell Automation FactoryTalk (View Point, View Machine, Linx): Mehrere Schwachstellen",
"tracking": {
"current_release_date": "2025-10-14T22:00:00.000+00:00",
"generator": {
"date": "2025-10-15T05:24:55.712+00:00",
"engine": {
"name": "BSI-WID",
"version": "1.4.0"
}
},
"id": "WID-SEC-W-2025-2273",
"initial_release_date": "2025-10-13T22:00:00.000+00:00",
"revision_history": [
{
"date": "2025-10-13T22:00:00.000+00:00",
"number": "1",
"summary": "Initiale Fassung"
},
{
"date": "2025-10-14T22:00:00.000+00:00",
"number": "2",
"summary": "Referenz(en) aufgenommen: EUVD-2025-34183, EUVD-2025-34181, EUVD-2025-34186, EUVD-2025-34185, EUVD-2025-34184"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "ViewPoint Panel View Plus 7 Terminal \u003cV14.103",
"product": {
"name": "Rockwell Automation FactoryTalk ViewPoint Panel View Plus 7 Terminal \u003cV14.103",
"product_id": "T047594"
}
},
{
"category": "product_version",
"name": "ViewPoint Panel View Plus 7 Terminal V14.103",
"product": {
"name": "Rockwell Automation FactoryTalk ViewPoint Panel View Plus 7 Terminal V14.103",
"product_id": "T047594-fixed",
"product_identification_helper": {
"cpe": "cpe:/a:rockwellautomation:factorytalk:viewpoint_panel_view_plus_7_terminal__v14.103"
}
}
},
{
"category": "product_version_range",
"name": "View Machine Edition \u003cV15.00",
"product": {
"name": "Rockwell Automation FactoryTalk View Machine Edition \u003cV15.00",
"product_id": "T047595"
}
},
{
"category": "product_version",
"name": "View Machine Edition V15.00",
"product": {
"name": "Rockwell Automation FactoryTalk View Machine Edition V15.00",
"product_id": "T047595-fixed",
"product_identification_helper": {
"cpe": "cpe:/a:rockwellautomation:factorytalk:view_machine_edition__v15.00"
}
}
},
{
"category": "product_version_range",
"name": "View Machine PanelView Plus 7 Performance Series B \u003cV14.103",
"product": {
"name": "Rockwell Automation FactoryTalk View Machine PanelView Plus 7 Performance Series B \u003cV14.103",
"product_id": "T047596"
}
},
{
"category": "product_version",
"name": "View Machine PanelView Plus 7 Performance Series B V14.103",
"product": {
"name": "Rockwell Automation FactoryTalk View Machine PanelView Plus 7 Performance Series B V14.103",
"product_id": "T047596-fixed",
"product_identification_helper": {
"cpe": "cpe:/a:rockwellautomation:factorytalk:view_machine_panelview_plus_7_performance_series_b__v14.103"
}
}
},
{
"category": "product_version_range",
"name": "Linx \u003c6.50",
"product": {
"name": "Rockwell Automation FactoryTalk Linx \u003c6.50",
"product_id": "T047597"
}
},
{
"category": "product_version",
"name": "Linx 6.50",
"product": {
"name": "Rockwell Automation FactoryTalk Linx 6.50",
"product_id": "T047597-fixed",
"product_identification_helper": {
"cpe": "cpe:/a:rockwellautomation:factorytalk:linx__6.50"
}
}
}
],
"category": "product_name",
"name": "FactoryTalk"
}
],
"category": "vendor",
"name": "Rockwell Automation"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-9063",
"product_status": {
"known_affected": [
"T047596"
]
},
"release_date": "2025-10-13T22:00:00.000+00:00",
"title": "CVE-2025-9063"
},
{
"cve": "CVE-2025-9064",
"product_status": {
"known_affected": [
"T047595",
"T047596"
]
},
"release_date": "2025-10-13T22:00:00.000+00:00",
"title": "CVE-2025-9064"
},
{
"cve": "CVE-2025-9066",
"product_status": {
"known_affected": [
"T047594"
]
},
"release_date": "2025-10-13T22:00:00.000+00:00",
"title": "CVE-2025-9066"
},
{
"cve": "CVE-2025-9067",
"product_status": {
"known_affected": [
"T047597"
]
},
"release_date": "2025-10-13T22:00:00.000+00:00",
"title": "CVE-2025-9067"
},
{
"cve": "CVE-2025-9068",
"product_status": {
"known_affected": [
"T047597"
]
},
"release_date": "2025-10-13T22:00:00.000+00:00",
"title": "CVE-2025-9068"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.