CVE-2025-5823 (GCVE-0-2025-5823)
Vulnerability from cvelistv5 – Published: 2025-06-25 18:01 – Updated: 2025-06-26 13:17- CWE-749 - Exposed Dangerous Method or Function
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Autel | Autel MaxiCharger AC Wallbox Commercial |
Affected:
1.36.00
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5823",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-26T13:16:57.354561Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-26T13:17:04.941Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Autel MaxiCharger AC Wallbox Commercial",
"vendor": "Autel",
"versions": [
{
"status": "affected",
"version": "1.36.00"
}
]
}
],
"dateAssigned": "2025-06-06T19:16:38.454Z",
"datePublic": "2025-06-11T17:27:01.850Z",
"descriptions": [
{
"lang": "en",
"value": "Autel MaxiCharger AC Wallbox Commercial Serial Number Exposed Dangerous Method Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the implementation of the Autel Technician API. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26351."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-749",
"description": "CWE-749: Exposed Dangerous Method or Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T18:01:07.948Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-25-341",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-25-341/"
}
],
"source": {
"lang": "en",
"value": "Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)"
},
"title": "Autel MaxiCharger AC Wallbox Commercial Serial Number Exposed Dangerous Method Information Disclosure Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2025-5823",
"datePublished": "2025-06-25T18:01:07.948Z",
"dateReserved": "2025-06-06T19:16:38.423Z",
"dateUpdated": "2025-06-26T13:17:04.941Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-5823",
"date": "2026-11-13",
"epss": "0.00558",
"percentile": "0.47051"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Autel MaxiCharger AC Wallbox Commercial",
"vendor": "Autel",
"versions": [
{
"status": "affected",
"version": "1.36.00"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:*:*:*:*:*:*:*:american_standard",
"matchCriteriaId": "0C17A950-221C-41E3-9BE3-31736CE4516F",
"versionEndExcluding": "1.39.51",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:*:*:*:*:*:*:*:european_standard",
"matchCriteriaId": "42F0DDFA-A1B9-4EC2-8F43-3261F9BCE814",
"versionEndExcluding": "1.56.51",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_ac_elite_business_c50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5B2F9001-71B7-4B39-9114-FC54F4EAE9E7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_pro_firmware:*:*:*:*:*:*:*:american_standard",
"matchCriteriaId": "9471EA48-BD48-40AA-8FF7-28503D04D1F0",
"versionEndExcluding": "1.39.51",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_pro_firmware:*:*:*:*:*:*:*:european_standard",
"matchCriteriaId": "72FB45A6-E876-45A6-A39F-4E0B28620A71",
"versionEndExcluding": "1.56.51",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_ac_pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "92CF3B40-B18F-4C4D-8A6C-68A8B1F288AE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_ultra_firmware:*:*:*:*:*:*:*:american_standard",
"matchCriteriaId": "55C717AF-39F9-4080-AE56-7511E0F62F79",
"versionEndExcluding": "1.39.51",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_ultra_firmware:*:*:*:*:*:*:*:european_standard",
"matchCriteriaId": "7AFD91E7-E581-451B-AB15-099AA7A4F611",
"versionEndExcluding": "1.56.51",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_ac_ultra:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDC6E5EB-C4D4-4488-B01B-C0E568FCA0D1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_mobile_firmware:*:*:*:*:*:*:*:american_standard",
"matchCriteriaId": "2C9AEB54-FFBC-4B24-AC7B-1B5F3CC762DF",
"versionEndExcluding": "1.39.51",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_mobile_firmware:*:*:*:*:*:*:*:european_standard",
"matchCriteriaId": "BBFCD8D0-53E7-4B06-B763-36381E13DD26",
"versionEndExcluding": "1.56.51",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_compact_mobile:-:*:*:*:*:*:*:*",
"matchCriteriaId": "52578631-C18D-4244-9377-AB787EDE08A1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_pedestal_firmware:*:*:*:*:*:*:*:american_standard",
"matchCriteriaId": "FED7B2BF-5D38-4393-9986-588407A3476D",
"versionEndExcluding": "1.39.51",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_pedestal_firmware:*:*:*:*:*:*:*:european_standard",
"matchCriteriaId": "3244FD64-1714-4597-BA66-CC5FC8D514FF",
"versionEndExcluding": "1.56.51",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_compact_pedestal:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ED75BBD9-D889-49D3-95B0-EF6F15B65E10",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_fast_firmware:*:*:*:*:*:*:*:american_standard",
"matchCriteriaId": "264E7F9D-0603-43C9-B7A9-6A35EA8F0063",
"versionEndExcluding": "1.39.51",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_fast_firmware:*:*:*:*:*:*:*:european_standard",
"matchCriteriaId": "E5F4FE58-5AA6-45D0-AE48-959DA0CF53C8",
"versionEndExcluding": "1.56.51",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_fast:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6C8B42B3-3F66-426F-8FFE-993FCAA12EB4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_hipower_firmware:*:*:*:*:*:*:*:american_standard",
"matchCriteriaId": "E30E7592-29C4-4333-A02C-7468074BD104",
"versionEndExcluding": "1.39.51",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_hipower_firmware:*:*:*:*:*:*:*:european_standard",
"matchCriteriaId": "F9058C73-831E-48BF-AE9B-19AB33F10F14",
"versionEndExcluding": "1.56.51",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_hipower:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE5DF603-DBD2-4AFF-AE3D-946277C2C6C2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dh480_firmware:*:*:*:*:*:*:*:american_standard",
"matchCriteriaId": "33F4A529-54C4-4EBC-871E-5E0C71859F69",
"versionEndExcluding": "1.39.51",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dh480_firmware:*:*:*:*:*:*:*:european_standard",
"matchCriteriaId": "62718E33-B591-49D4-8CC6-057D6254873A",
"versionEndExcluding": "1.56.51",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dh480:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CAD62E93-8613-48DF-9C42-B12655FE1680",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_single_charger_firmware:*:*:*:*:*:*:*:american_standard",
"matchCriteriaId": "372D3478-67AA-4D41-908C-5CFE6CAA25A8",
"versionEndExcluding": "1.39.51",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_single_charger_firmware:*:*:*:*:*:*:*:european_standard",
"matchCriteriaId": "8ED07235-5610-4E80-8940-6EB942CC648C",
"versionEndExcluding": "1.56.51",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_single_charger:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0E6B2074-D4A6-424F-B7C5-40A0FE5C17F8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Autel MaxiCharger AC Wallbox Commercial Serial Number Exposed Dangerous Method Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the implementation of the Autel Technician API. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26351."
},
{
"lang": "es",
"value": "Vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n por m\u00e9todo peligroso expuesta en el n\u00famero de serie del Autel MaxiCharger AC Wallbox Commercial. Esta vulnerabilidad permite a atacantes remotos divulgar informaci\u00f3n confidencial sobre las instalaciones afectadas de los cargadores para veh\u00edculos el\u00e9ctricos Autel MaxiCharger AC Wallbox Commercial. Se requiere autenticaci\u00f3n para explotar esta vulnerabilidad. La falla espec\u00edfica se encuentra en la implementaci\u00f3n de la API Autel Technician. El problema se debe a un m\u00e9todo peligroso expuesto. Un atacante puede aprovechar esta vulnerabilidad para divulgar credenciales, lo que conlleva una mayor vulnerabilidad. Se denomin\u00f3 ZDI-CAN-26351."
}
],
"id": "CVE-2025-5823",
"lastModified": "2026-06-17T09:48:48.993",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-5823",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-26T13:16:57.354561Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-06-25T18:15:23.043",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-25-341/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-749"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-06-27T18:18:09+00:00",
"cve": "CVE-2025-5823",
"id": "CVE-2025-5823",
"initial_release_date": "2025-06-11T17:27:01.850000+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Autel MaxiCharger AC Wallbox Commercial Serial Number Exposed Dangerous Method Information Disclosure Vulnerability",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-5823.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5823",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-26T13:16:57.354561Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-26T13:17:01.195Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Autel MaxiCharger AC Wallbox Commercial",
"vendor": "Autel",
"versions": [
{
"status": "affected",
"version": "1.36.00"
}
]
}
],
"dateAssigned": "2025-06-06T19:16:38.454Z",
"datePublic": "2025-06-11T17:27:01.850Z",
"descriptions": [
{
"lang": "en",
"value": "Autel MaxiCharger AC Wallbox Commercial Serial Number Exposed Dangerous Method Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the implementation of the Autel Technician API. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26351."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-749",
"description": "CWE-749: Exposed Dangerous Method or Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-25T18:01:07.948Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-25-341",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-25-341/"
}
],
"source": {
"lang": "en",
"value": "Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)"
},
"title": "Autel MaxiCharger AC Wallbox Commercial Serial Number Exposed Dangerous Method Information Disclosure Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2025-5823",
"datePublished": "2025-06-25T18:01:07.948Z",
"dateReserved": "2025-06-06T19:16:38.423Z",
"dateUpdated": "2025-06-26T13:17:04.941Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.