CVE-2025-15256 (GCVE-0-2025-15256)
Vulnerability from cvelistv5 – Published: 2025-12-30 16:32 – Updated: 2026-02-24 06:18 Unsupported When Assigned| URL | Tags |
|---|---|
| https://vuldb.com/?id.338646 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.338646 | signaturepermissions-required |
| https://vuldb.com/?submit.722014 | third-party-advisory |
| https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_… | exploit |
| https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-15256",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-30T18:09:24.781917Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T18:11:43.621Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Web-based Configuration Interface"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.02"
},
{
"status": "affected",
"version": "1.03"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "tian (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manipulation of the argument rootAPmac leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. Edimax confirms this issue: \"The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security.\" This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:C",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:C",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-24T06:18:04.258Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-338646 | Edimax BR-6208AC Web-based Configuration formStaDrvSetup command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.338646"
},
{
"name": "VDB-338646 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.338646"
},
{
"name": "Submit #722014 | Edimax BR-6208AC V2_1.02 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.722014"
},
{
"tags": [
"exploit"
],
"url": "https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b?source=copy_link"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2025-12-29T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-29T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-14T03:46:39.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC Web-based Configuration formStaDrvSetup command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-15256",
"datePublished": "2025-12-30T16:32:06.090Z",
"dateReserved": "2025-12-29T09:34:40.999Z",
"dateUpdated": "2026-02-24T06:18:04.258Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-15256",
"date": "2026-11-14",
"epss": "0.03761",
"percentile": "0.90082"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Web-based Configuration Interface"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.02"
},
{
"status": "affected",
"version": "1.03"
}
]
}
],
"source": "cna@vuldb.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:edimax:br-6208ac_firmware:1.02:*:*:*:*:*:*:*",
"matchCriteriaId": "A157430A-029A-41E3-B128-E365363609BF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:edimax:br-6208ac_firmware:1.03:*:*:*:*:*:*:*",
"matchCriteriaId": "CE385640-FDDC-41C5-AD1C-36283B878411",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:edimax:br-6208ac:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "925424B0-B731-4AB3-A348-3E8684962993",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [
{
"sourceIdentifier": "cna@vuldb.com",
"tags": [
"unsupported-when-assigned"
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manipulation of the argument rootAPmac leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. Edimax confirms this issue: \"The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security.\" This vulnerability only affects products that are no longer supported by the maintainer."
},
{
"lang": "es",
"value": "Se identific\u00f3 una vulnerabilidad en Edimax BR-6208AC 1.02/1.03. Afectada est\u00e1 la funci\u00f3n formStaDrvSetup del archivo /goform/formStaDrvSetup del componente Interfaz de Configuraci\u00f3n Basada en Web. La manipulaci\u00f3n del argumento rootAPmac conduce a una inyecci\u00f3n de comandos. Es posible la explotaci\u00f3n remota del ataque. El exploit est\u00e1 disponible p\u00fablicamente y podr\u00eda ser utilizado. Edimax confirma este problema: \u0027El producto mencionado, EDIMAX BR-6208AC V2, ha alcanzado su estado de Fin de Vida \u00datil (EOL). Ya no es compatible ni mantenido por Edimax, y ya no est\u00e1 disponible para su compra en el mercado. En consecuencia, no habr\u00e1 m\u00e1s actualizaciones de firmware ni parches para este dispositivo. Recomendamos a los usuarios actualizar a modelos m\u00e1s nuevos para una mejor seguridad.\u0027 Esta vulnerabilidad solo afecta a productos que ya no son compatibles con el mantenedor."
}
],
"id": "CVE-2025-15256",
"lastModified": "2026-06-17T08:37:28.653",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.4,
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "PROOF_OF_CONCEPT",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cna@vuldb.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-15256",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-30T18:09:24.781917Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-12-30T17:15:41.027",
"references": [
{
"source": "cna@vuldb.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b?source=copy_link"
},
{
"source": "cna@vuldb.com",
"tags": [
"Permissions Required",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.338646"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.338646"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?submit.722014"
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-74"
},
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T08:56:41+00:00",
"cve": "CVE-2025-15256",
"id": "CVE-2025-15256",
"initial_release_date": "2025-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Edimax BR-6208AC Web-based Configuration formStaDrvSetup command injection",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-15256.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-15256",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-30T18:09:24.781917Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T18:09:36.347Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Web-based Configuration Interface"
],
"product": "BR-6208AC",
"vendor": "Edimax",
"versions": [
{
"status": "affected",
"version": "1.02"
},
{
"status": "affected",
"version": "1.03"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "tian (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manipulation of the argument rootAPmac leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. Edimax confirms this issue: \"The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security.\" This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:C",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:C",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-24T06:18:04.258Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-338646 | Edimax BR-6208AC Web-based Configuration formStaDrvSetup command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.338646"
},
{
"name": "VDB-338646 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.338646"
},
{
"name": "Submit #722014 | Edimax BR-6208AC V2_1.02 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.722014"
},
{
"tags": [
"exploit"
],
"url": "https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b?source=copy_link"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2025-12-29T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-29T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-14T03:46:39.000Z",
"value": "VulDB entry last update"
}
],
"title": "Edimax BR-6208AC Web-based Configuration formStaDrvSetup command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-15256",
"datePublished": "2025-12-30T16:32:06.090Z",
"dateReserved": "2025-12-29T09:34:40.999Z",
"dateUpdated": "2026-02-24T06:18:04.258Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.