CVE-2024-35207 (GCVE-0-2024-35207)
Vulnerability from cvelistv5 – Published: 2024-06-11 11:15 – Updated: 2024-08-02 03:07
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery(CSRF) attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-11 16:52 UTC
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Siemens | SINEC Traffic Analyzer |
Affected:
0 , < V1.2
(custom)
|
guessed | |
| siemens | sinec_traffic_analyzer |
Affected:
0 , < 1.2
(custom)
cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinec_traffic_analyzer",
"vendor": "siemens",
"versions": [
{
"lessThan": "1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-35207",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-11T16:52:38.612557Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T16:55:45.445Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:07:46.833Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-196737.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SINEC Traffic Analyzer",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions \u003c V1.2). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery(CSRF) attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352: Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:49.728Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-196737.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-35207",
"datePublished": "2024-06-11T11:15:47.708Z",
"dateReserved": "2024-05-13T17:54:10.655Z",
"dateUpdated": "2024-08-02T03:07:46.833Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-35207",
"date": "2026-10-19",
"epss": "0.00155",
"percentile": "0.04205"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SINEC Traffic Analyzer",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "productcert@siemens.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinec_traffic_analyzer",
"vendor": "siemens",
"versions": [
{
"lessThan": "1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*",
"matchCriteriaId": "629B3242-572B-4E48-945A-DADB5C7702AA",
"versionEndExcluding": "1.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions \u003c V1.2). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery(CSRF) attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (Todas las versiones \u0026lt; V1.2). La interfaz web de los dispositivos afectados es vulnerable a ataques de Cross-Site Request Forgery (CSRF). Al enga\u00f1ar a un usuario v\u00edctima autenticado para que haga clic en un enlace malicioso, un atacante podr\u00eda realizar acciones arbitrarias en el dispositivo en nombre del usuario v\u00edctima."
}
],
"id": "CVE-2024-35207",
"lastModified": "2026-06-17T07:34:32.830",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "productcert@siemens.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-35207",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-11T16:52:38.612557Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-06-11T12:15:16.600",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-196737.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-196737.html"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T20:06:47+00:00",
"cve": "CVE-2024-35207",
"id": "CVE-2024-35207",
"initial_release_date": "2024-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2024-35207",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-35207.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinec_traffic_analyzer",
"vendor": "siemens",
"versions": [
{
"lessThan": "1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-35207",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-11T16:52:38.612557Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T16:55:41.320Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SINEC Traffic Analyzer",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions \u003c V1.2). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery(CSRF) attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352: Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T14:20:49.728Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-196737.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-35207",
"datePublished": "2024-06-11T11:15:47.708Z",
"dateReserved": "2024-05-13T17:54:10.655Z",
"dateUpdated": "2024-06-11T16:55:45.445Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour