CVE-2024-21916 (GCVE-0-2024-21916)

Vulnerability from cvelistv5 – Published: 2024-01-31 18:28 – Updated: 2024-08-01 22:35
VLAI
Title
Rockwell Automation Denial-of-service Vulnerability in ICE1 Controller
Summary
A denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-02-06 05:00 UTC
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
Rockwell CNA under the icscert root
CNA scorecard C 74/100 over 47 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Rockwell Automation ControlLogix® 5570 Affected: 20.011
guessed Create a notification for this product.
Rockwell Automation GuardLogix® 5570 Affected: 20.011
guessed Create a notification for this product.
Rockwell Automation ControlLogix® 5570 redundant Affected: 20.054_kit1
guessed Create a notification for this product.
rockwellautomation controllogix_5570_controller_firmware Affected: 20.011
    cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*
Create a notification for this product.
rockwellautomation guardlogix_5570_controller_firmware Affected: 20.011
    cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*
Create a notification for this product.
rockwellautomation controllogix_5570_redundant_controller_firmware Affected: 20.054_kit1
    cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.054_kit1:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-01-30 14:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "controllogix_5570_controller_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "20.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "guardlogix_5570_controller_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "20.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.054_kit1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "controllogix_5570_redundant_controller_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "20.054_kit1"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-21916",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-06T05:00:32.025684Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-01T19:54:41.466Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:35:34.618Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix\u00ae 5570",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "20.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GuardLogix\u00ae 5570",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "20.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix\u00ae 5570 redundant",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "20.054_kit1"
            }
          ]
        }
      ],
      "datePublic": "2024-01-30T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMNRF.\u003c/a\u003e"
            }
          ],
          "value": "\nA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-31T18:28:59.715Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cul\u003e\u003cli\u003eUpdate to corrected Firmware.\u0026nbsp;\u003c/li\u003e\u003c/ul\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eAffected Product\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eFirst Known in Firmware\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in Firmware\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5570\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eGuardLogix\u00ae 5570\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5570 redundant\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.054_kit1\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\n\n\u003cbr\u003e\n\n"
            }
          ],
          "value": "\n  *  Update to corrected Firmware.\u00a0\n\n\n\n\nAffected Product\n\nFirst Known in Firmware\n\nCorrected in Firmware\n\nControlLogix\u00ae 5570\n\n20.011\n\nv33.016, 34.013, 35.012, 36.011 and later\n\nGuardLogix\u00ae 5570\n\n20.011\n\nv33.016, 34.013, 35.012, 36.011 and later\n\nControlLogix\u00ae 5570 redundant\n\n20.054_kit1\n\nv33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\n\n\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rockwell Automation Denial-of-service Vulnerability in ICE1 Controller",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-21916",
    "datePublished": "2024-01-31T18:28:59.715Z",
    "dateReserved": "2024-01-03T16:40:50.367Z",
    "dateUpdated": "2024-08-01T22:35:34.618Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-21916",
      "date": "2026-11-08",
      "epss": "0.00648",
      "percentile": "0.51329"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "ControlLogix\u00ae 5570",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20.011"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "GuardLogix\u00ae 5570",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20.011"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "ControlLogix\u00ae 5570 redundant",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20.054_kit1"
                  }
                ]
              }
            ],
            "source": "PSIRT@rockwellautomation.com"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "controllogix_5570_controller_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20.011"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "guardlogix_5570_controller_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20.011"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.054_kit1:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "controllogix_5570_redundant_controller_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20.054_kit1"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*",
                    "matchCriteriaId": "06E12A7B-E32C-46DE-891B-B42586053A33",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5570_controller:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C16C24E2-4CB6-4413-8D48-588E0246617E",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6D5A9D00-9B54-4A85-9E9D-652FA0BC911F",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5570_controller:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B4B273FA-0865-4505-AAF8-1676940A3EA9",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.054_kit1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9CA7904D-3C8B-4CED-B2AB-0CCD266B148F",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5570_redundant_controller:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "898183DD-C3AE-42EE-9891-81BFA774476A",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "\nA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF."
          },
          {
            "lang": "es",
            "value": "Existe una vulnerabilidad de denegaci\u00f3n de servicio en controladores Rockwell Automation ControlLogix ang GuardLogix. Si se explota, el producto podr\u00eda experimentar un fallo importante no recuperable (MNRF). El dispositivo se reiniciar\u00e1 solo para recuperarse del MNRF."
          }
        ],
        "id": "CVE-2024-21916",
        "lastModified": "2026-06-17T07:10:24.450",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 4.0,
              "source": "PSIRT@rockwellautomation.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-21916",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-06T05:00:32.025684Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-01-31T19:15:08.427",
        "references": [
          {
            "source": "PSIRT@rockwellautomation.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html"
          }
        ],
        "sourceIdentifier": "PSIRT@rockwellautomation.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              }
            ],
            "source": "PSIRT@rockwellautomation.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T20:57:28+00:00",
      "cve": "CVE-2024-21916",
      "id": "CVE-2024-21916",
      "initial_release_date": "2024-01-30T14:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Rockwell Automation Denial-of-service Vulnerability in ICE1 Controller",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-21916.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T22:35:34.618Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "controllogix_5570_controller_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20.011"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "guardlogix_5570_controller_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20.011"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.054_kit1:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "controllogix_5570_redundant_controller_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20.054_kit1"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-21916",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-02-06T05:00:32.025684Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-01T19:53:42.020Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ControlLogix\u00ae 5570",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "20.011"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GuardLogix\u00ae 5570",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "20.011"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ControlLogix\u00ae 5570 redundant",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "20.054_kit1"
                }
              ]
            }
          ],
          "datePublic": "2024-01-30T14:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMNRF.\u003c/a\u003e"
                }
              ],
              "value": "\nA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-31T18:28:59.715Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cul\u003e\u003cli\u003eUpdate to corrected Firmware.\u0026nbsp;\u003c/li\u003e\u003c/ul\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eAffected Product\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eFirst Known in Firmware\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in Firmware\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5570\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eGuardLogix\u00ae 5570\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5570 redundant\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.054_kit1\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\n\n\u003cbr\u003e\n\n"
                }
              ],
              "value": "\n  *  Update to corrected Firmware.\u00a0\n\n\n\n\nAffected Product\n\nFirst Known in Firmware\n\nCorrected in Firmware\n\nControlLogix\u00ae 5570\n\n20.011\n\nv33.016, 34.013, 35.012, 36.011 and later\n\nGuardLogix\u00ae 5570\n\n20.011\n\nv33.016, 34.013, 35.012, 36.011 and later\n\nControlLogix\u00ae 5570 redundant\n\n20.054_kit1\n\nv33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\n\n\n\n\n\n\n"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Rockwell Automation Denial-of-service Vulnerability in ICE1 Controller",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2024-21916",
        "datePublished": "2024-01-31T18:28:59.715Z",
        "dateReserved": "2024-01-03T16:40:50.367Z",
        "dateUpdated": "2024-08-01T22:35:34.618Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.