CVE-2024-10387 (GCVE-0-2024-10387)

Vulnerability from cvelistv5 – Published: 2024-10-25 17:04 – Updated: 2024-10-25 20:14
VLAI
Title
Rockwell Automation FactoryTalk ThinManager Denial-of-Service Vulnerability
Summary
CVE-2024-10387 IMPACT A Denial-of-Service vulnerability exists in the affected product. The vulnerability could allow a threat actor with network access to send crafted messages to the device, potentially resulting in Denial-of-Service.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-25 20:10 UTC
CWE
Assigner
Rockwell CNA under the icscert root
CNA scorecard C 74/100 over 47 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Rockwell Automation FactoryTalk ThinManager Affected: 11.2.0-11.2.9
Affected: 12.0.0-12.0.7
Affected: 12.1.0-12.1.8
Affected: 13.0.0-13.0.5
Affected: 13.1.0-13.1.3
Affected: 13.2.0-13.2.2
Affected: 14.0.0
guessed Create a notification for this product.
rockwellautomation thinmanager Affected: 11.2.0 , ≤ 11.2.9 (custom)
Affected: 12.0.0 , ≤ 12.0.7 (custom)
Affected: 12.1.0 , ≤ 12.1.8 (custom)
Affected: 13.0.0 , ≤ 13.0.5 (custom)
Affected: 13.1.0 , ≤ 13.1.3 (custom)
Affected: 13.2.0 , ≤ 13.2.2 (custom)
Affected: 14.0.0
    cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-10-25 17:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "thinmanager",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "lessThanOrEqual": "11.2.9",
                "status": "affected",
                "version": "11.2.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "12.0.7",
                "status": "affected",
                "version": "12.0.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "12.1.8",
                "status": "affected",
                "version": "12.1.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "13.0.5",
                "status": "affected",
                "version": "13.0.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "13.1.3",
                "status": "affected",
                "version": "13.1.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "13.2.2",
                "status": "affected",
                "version": "13.2.0",
                "versionType": "custom"
              },
              {
                "status": "affected",
                "version": "14.0.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10387",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-25T20:10:20.475990Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-25T20:14:03.121Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk ThinManager",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "11.2.0-11.2.9"
            },
            {
              "status": "affected",
              "version": "12.0.0-12.0.7"
            },
            {
              "status": "affected",
              "version": "12.1.0-12.1.8"
            },
            {
              "status": "affected",
              "version": "13.0.0-13.0.5"
            },
            {
              "status": "affected",
              "version": "13.1.0-13.1.3"
            },
            {
              "status": "affected",
              "version": "13.2.0-13.2.2"
            },
            {
              "status": "affected",
              "version": "14.0.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Tenable Network Security"
        }
      ],
      "datePublic": "2024-10-25T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cb\u003e\u003cu\u003eCVE-2024-10387 IMPACT\u003c/u\u003e\u003c/b\u003e\u003cu\u003e\u003c/u\u003e\u003c/p\u003e\n\n\u003cp\u003eA Denial-of-Service\nvulnerability exists in the affected product. The vulnerability could allow a\nthreat actor with network access to send crafted messages to the device,\npotentially resulting in Denial-of-Service.\u003c/p\u003e"
            }
          ],
          "value": "CVE-2024-10387 IMPACT\n\n\n\nA Denial-of-Service\nvulnerability exists in the affected product. The vulnerability could allow a\nthreat actor with network access to send crafted messages to the device,\npotentially resulting in Denial-of-Service."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-129",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-129 Pointer Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-25T17:04:36.334Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1708.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: var(--wht);\"\u003eIf able,\nnavigate to the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://thinmanager.com/downloads/\"\u003eThinManager\u00ae download site\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e and upgrade to a corrected version of ThinManager\u00ae\u003c/span\u003e\n\n\u003cbr\u003e\u003cbr\u003e\u003cp\u003e11.2.10\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e12.0.8\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e12.1.9\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e13.0.6 \u003c/p\u003e\n\n\n\n\u003cp\u003e13.1.4 \u003c/p\u003e\n\n\n\n\u003cp\u003e13.2.3 \u003c/p\u003e\n\n\n\n\u003cp\u003e14.0.1\u003c/p\u003e\n\n\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "If able,\nnavigate to the  ThinManager\u00ae download site https://thinmanager.com/downloads/  and upgrade to a corrected version of ThinManager\u00ae\n\n\n\n11.2.10\n\n\n\n\n\n12.0.8\n\n\n\n\n\n12.1.9\n\n\n\n\n\n13.0.6 \n\n\n\n\n\n13.1.4 \n\n\n\n\n\n13.2.3 \n\n\n\n\n\n14.0.1"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk ThinManager Denial-of-Service Vulnerability",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eIf able,\nnavigate to the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://thinmanager.com/downloads/\"\u003eThinManager\u00ae download site\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e and upgrade to a corrected version of ThinManager\u00ae\u003c/span\u003e\u003c/p\u003e\u003cp\u003eImplement\nnetwork hardening for ThinManager\u00ae Device(s) by limiting communications to TCP\n2031 to only the devices that need connection to the ThinManager\u00ae\u003c/p\u003e\n\n\n\n\u003cp\u003eFor\ninformation on how to mitigate Security Risks on industrial automation control\nsystems, we encourage customers to implement our suggested \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003esecurity best\npractices\u003c/a\u003e to\nminimize the risk of the vulnerability.\u003c/p\u003e"
            }
          ],
          "value": "If able,\nnavigate to the  ThinManager\u00ae download site https://thinmanager.com/downloads/  and upgrade to a corrected version of ThinManager\u00ae\n\nImplement\nnetwork hardening for ThinManager\u00ae Device(s) by limiting communications to TCP\n2031 to only the devices that need connection to the ThinManager\u00ae\n\n\n\n\n\nFor\ninformation on how to mitigate Security Risks on industrial automation control\nsystems, we encourage customers to implement our suggested security best\npractices to\nminimize the risk of the vulnerability."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-10387",
    "datePublished": "2024-10-25T17:04:36.334Z",
    "dateReserved": "2024-10-25T12:38:30.428Z",
    "dateUpdated": "2024-10-25T20:14:03.121Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-10387",
      "date": "2026-11-16",
      "epss": "0.07977",
      "percentile": "0.94842"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "FactoryTalk ThinManager",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "11.2.0-11.2.9"
                  },
                  {
                    "status": "affected",
                    "version": "12.0.0-12.0.7"
                  },
                  {
                    "status": "affected",
                    "version": "12.1.0-12.1.8"
                  },
                  {
                    "status": "affected",
                    "version": "13.0.0-13.0.5"
                  },
                  {
                    "status": "affected",
                    "version": "13.1.0-13.1.3"
                  },
                  {
                    "status": "affected",
                    "version": "13.2.0-13.2.2"
                  },
                  {
                    "status": "affected",
                    "version": "14.0.0"
                  }
                ]
              }
            ],
            "source": "PSIRT@rockwellautomation.com"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "thinmanager",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "lessThanOrEqual": "11.2.9",
                    "status": "affected",
                    "version": "11.2.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "12.0.7",
                    "status": "affected",
                    "version": "12.0.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "12.1.8",
                    "status": "affected",
                    "version": "12.1.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "13.0.5",
                    "status": "affected",
                    "version": "13.0.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "13.1.3",
                    "status": "affected",
                    "version": "13.1.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "13.2.2",
                    "status": "affected",
                    "version": "13.2.0",
                    "versionType": "custom"
                  },
                  {
                    "status": "affected",
                    "version": "14.0.0"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AC6CF373-34C9-43AC-B210-2E7C31CEAEFA",
                    "versionEndExcluding": "11.2.10",
                    "versionStartIncluding": "11.2.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9EAE9FF9-28B3-4490-8358-A3636FFDC9C8",
                    "versionEndExcluding": "12.0.8",
                    "versionStartIncluding": "12.0.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "667ACE9F-6074-4300-A90A-5C6F8A06B76A",
                    "versionEndExcluding": "12.1.9",
                    "versionStartIncluding": "12.1.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C56E6406-256A-4774-9FDD-E72625D4B1AA",
                    "versionEndExcluding": "13.0.6",
                    "versionStartIncluding": "13.0.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0305A358-81AA-468A-951D-98EE0C60695C",
                    "versionEndIncluding": "13.1.4",
                    "versionStartIncluding": "13.1.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4B920868-E568-44A7-9F68-B3D615956E12",
                    "versionEndIncluding": "13.2.3",
                    "versionStartIncluding": "13.2.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:14.0.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "48214ABF-9E29-4422-A0E6-6AF4AE199D51",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "CVE-2024-10387 IMPACT\n\n\n\nA Denial-of-Service\nvulnerability exists in the affected product. The vulnerability could allow a\nthreat actor with network access to send crafted messages to the device,\npotentially resulting in Denial-of-Service."
          },
          {
            "lang": "es",
            "value": "CVE-2024-10387 IMPACTO Existe una vulnerabilidad de denegaci\u00f3n de servicio en el producto afectado. La vulnerabilidad podr\u00eda permitir que un actor de amenazas con acceso a la red env\u00ede mensajes manipulados al dispositivo, lo que podr\u00eda provocar una denegaci\u00f3n de servicio."
          }
        ],
        "id": "CVE-2024-10387",
        "lastModified": "2026-06-17T06:55:32.293",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "PSIRT@rockwellautomation.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "PSIRT@rockwellautomation.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-10387",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-25T20:10:20.475990Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-10-25T17:15:04.230",
        "references": [
          {
            "source": "PSIRT@rockwellautomation.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1708.html"
          }
        ],
        "sourceIdentifier": "PSIRT@rockwellautomation.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-125"
              }
            ],
            "source": "PSIRT@rockwellautomation.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "NVD-CWE-noinfo"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T19:41:25+00:00",
      "cve": "CVE-2024-10387",
      "id": "CVE-2024-10387",
      "initial_release_date": "2024-10-25T17:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Rockwell Automation FactoryTalk ThinManager Denial-of-Service Vulnerability",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-10387.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "thinmanager",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "lessThanOrEqual": "11.2.9",
                    "status": "affected",
                    "version": "11.2.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "12.0.7",
                    "status": "affected",
                    "version": "12.0.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "12.1.8",
                    "status": "affected",
                    "version": "12.1.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "13.0.5",
                    "status": "affected",
                    "version": "13.0.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "13.1.3",
                    "status": "affected",
                    "version": "13.1.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "13.2.2",
                    "status": "affected",
                    "version": "13.2.0",
                    "versionType": "custom"
                  },
                  {
                    "status": "affected",
                    "version": "14.0.0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-10387",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-25T20:10:20.475990Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-25T20:13:42.749Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FactoryTalk ThinManager",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "11.2.0-11.2.9"
                },
                {
                  "status": "affected",
                  "version": "12.0.0-12.0.7"
                },
                {
                  "status": "affected",
                  "version": "12.1.0-12.1.8"
                },
                {
                  "status": "affected",
                  "version": "13.0.0-13.0.5"
                },
                {
                  "status": "affected",
                  "version": "13.1.0-13.1.3"
                },
                {
                  "status": "affected",
                  "version": "13.2.0-13.2.2"
                },
                {
                  "status": "affected",
                  "version": "14.0.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Tenable Network Security"
            }
          ],
          "datePublic": "2024-10-25T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\u003cb\u003e\u003cu\u003eCVE-2024-10387 IMPACT\u003c/u\u003e\u003c/b\u003e\u003cu\u003e\u003c/u\u003e\u003c/p\u003e\n\n\u003cp\u003eA Denial-of-Service\nvulnerability exists in the affected product. The vulnerability could allow a\nthreat actor with network access to send crafted messages to the device,\npotentially resulting in Denial-of-Service.\u003c/p\u003e"
                }
              ],
              "value": "CVE-2024-10387 IMPACT\n\n\n\nA Denial-of-Service\nvulnerability exists in the affected product. The vulnerability could allow a\nthreat actor with network access to send crafted messages to the device,\npotentially resulting in Denial-of-Service."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-129",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-129 Pointer Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-25T17:04:36.334Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1708.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: var(--wht);\"\u003eIf able,\nnavigate to the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://thinmanager.com/downloads/\"\u003eThinManager\u00ae download site\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e and upgrade to a corrected version of ThinManager\u00ae\u003c/span\u003e\n\n\u003cbr\u003e\u003cbr\u003e\u003cp\u003e11.2.10\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e12.0.8\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e12.1.9\u003cbr\u003e\n\u003c/p\u003e\n\n\u003cp\u003e13.0.6 \u003c/p\u003e\n\n\n\n\u003cp\u003e13.1.4 \u003c/p\u003e\n\n\n\n\u003cp\u003e13.2.3 \u003c/p\u003e\n\n\n\n\u003cp\u003e14.0.1\u003c/p\u003e\n\n\n\n\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "If able,\nnavigate to the  ThinManager\u00ae download site https://thinmanager.com/downloads/  and upgrade to a corrected version of ThinManager\u00ae\n\n\n\n11.2.10\n\n\n\n\n\n12.0.8\n\n\n\n\n\n12.1.9\n\n\n\n\n\n13.0.6 \n\n\n\n\n\n13.1.4 \n\n\n\n\n\n13.2.3 \n\n\n\n\n\n14.0.1"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Rockwell Automation FactoryTalk ThinManager Denial-of-Service Vulnerability",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eIf able,\nnavigate to the \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://thinmanager.com/downloads/\"\u003eThinManager\u00ae download site\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e and upgrade to a corrected version of ThinManager\u00ae\u003c/span\u003e\u003c/p\u003e\u003cp\u003eImplement\nnetwork hardening for ThinManager\u00ae Device(s) by limiting communications to TCP\n2031 to only the devices that need connection to the ThinManager\u00ae\u003c/p\u003e\n\n\n\n\u003cp\u003eFor\ninformation on how to mitigate Security Risks on industrial automation control\nsystems, we encourage customers to implement our suggested \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003esecurity best\npractices\u003c/a\u003e to\nminimize the risk of the vulnerability.\u003c/p\u003e"
                }
              ],
              "value": "If able,\nnavigate to the  ThinManager\u00ae download site https://thinmanager.com/downloads/  and upgrade to a corrected version of ThinManager\u00ae\n\nImplement\nnetwork hardening for ThinManager\u00ae Device(s) by limiting communications to TCP\n2031 to only the devices that need connection to the ThinManager\u00ae\n\n\n\n\n\nFor\ninformation on how to mitigate Security Risks on industrial automation control\nsystems, we encourage customers to implement our suggested security best\npractices to\nminimize the risk of the vulnerability."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2024-10387",
        "datePublished": "2024-10-25T17:04:36.334Z",
        "dateReserved": "2024-10-25T12:38:30.428Z",
        "dateUpdated": "2024-10-25T20:14:03.121Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Solutions

CNA · Rockwell
If able, navigate to the ThinManager® download site https://thinmanager.com/downloads/ and upgrade to a corrected version of ThinManager® 11.2.10 12.0.8 12.1.9 13.0.6 13.1.4 13.2.3 14.0.1

Workarounds

CNA · Rockwell
If able, navigate to the ThinManager® download site https://thinmanager.com/downloads/ and upgrade to a corrected version of ThinManager® Implement network hardening for ThinManager® Device(s) by limiting communications to TCP 2031 to only the devices that need connection to the ThinManager® For information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested security best practices to minimize the risk of the vulnerability.

Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.