CVE-2022-29825 (GCVE-0-2022-29825)
Vulnerability from cvelistv5 – Published: 2022-11-24 23:21 – Updated: 2025-11-07 06:49- CWE-259 - Use of Hard-coded Password
| URL | Tags |
|---|---|
| https://www.mitsubishielectric.com/en/psirt/vulne… | vendor-advisory |
| https://jvn.jp/vu/JVNVU97244961/index.html | government-resource |
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | government-resource |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Mitsubishi Electric Corporation | GX Works3 |
Affected:
from 1.000A to 1.090U
|
guessed | |
| Mitsubishi Electric Corporation | GT Designer3 Version1 (GOT2000) |
Affected:
from 1.122C to 1.290C
|
guessed | |
| Mitsubishi Electric Corporation | MT Works2 |
Affected:
from 1.100E to 1.200J
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:33:42.627Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU97244961/index.html"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-29825",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-25T17:52:17.273503Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-25T17:52:21.905Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GX Works3",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "from 1.000A to 1.090U"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GT Designer3 Version1 (GOT2000)",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "from 1.122C to 1.290C"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MT Works2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "from 1.100E to 1.200J"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
}
],
"value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259 Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-07T06:49:29.712Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU97244961/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-29825",
"datePublished": "2022-11-24T23:21:54.776Z",
"dateReserved": "2022-04-27T20:47:43.441Z",
"dateUpdated": "2025-11-07T06:49:29.712Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-29825",
"date": "2026-11-14",
"epss": "0.00492",
"percentile": "0.4284"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "GX Works3",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "from 1.000A to 1.090U"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GT Designer3 Version1 (GOT2000)",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "from 1.122C to 1.290C"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MT Works2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "from 1.100E to 1.200J"
}
]
}
],
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297",
"versionEndIncluding": "1.011m",
"versionStartIncluding": "1.000a",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
"versionEndIncluding": "1.086q",
"versionStartIncluding": "1.015r",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
"versionStartIncluding": "1.087r",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
},
{
"lang": "es",
"value": "El uso de la vulnerabilidad de contrase\u00f1a codificada en las versiones Mitsubishi Electric GX Works3 de 1.000A a 1.090U y GT Designer3 Versi\u00f3n1 (GOT2000) de 1.122C a 1.290C permite que un atacante no autenticado revele informaci\u00f3n sensible. Como resultado, los usuarios no autenticados pueden ver programas y archivos de proyectos o ejecutar programas ilegalmente."
}
],
"id": "CVE-2022-29825",
"lastModified": "2026-06-17T04:40:46.717",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.1,
"impactScore": 4.0,
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-29825",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-25T17:52:17.273503Z",
"version": "2.0.3"
}
}
]
},
"published": "2022-11-25T00:15:10.000",
"references": [
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://jvn.jp/vu/JVNVU97244961/index.html"
},
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
},
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://jvn.jp/vu/JVNVU97244961/index.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
}
],
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-259"
}
],
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-11-07T07:47:22+00:00",
"cve": "CVE-2022-29825",
"id": "CVE-2022-29825",
"initial_release_date": "2022-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2022-29825",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-29825.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:33:42.627Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU97244961/index.html"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-29825",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-25T17:52:17.273503Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-25T17:51:59.161Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GX Works3",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "from 1.000A to 1.090U"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GT Designer3 Version1 (GOT2000)",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "from 1.122C to 1.290C"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MT Works2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "from 1.100E to 1.200J"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
}
],
"value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259 Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-07T06:49:29.712Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU97244961/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-29825",
"datePublished": "2022-11-24T23:21:54.776Z",
"dateReserved": "2022-04-27T20:47:43.441Z",
"dateUpdated": "2025-11-07T06:49:29.712Z",
"requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.