CVE-2021-33478 (GCVE-0-2021-33478)
Vulnerability from cvelistv5 – Published: 2021-07-22 16:53 – Updated: 2024-08-03 23:50- n/a
| URL | Tags |
|---|---|
| https://tools.cisco.com/security/center/content/C… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:50:42.938Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-brcm-mxc-jul2021-26LqUZUh"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The TrustZone implementation in certain Broadcom MediaxChange firmware could allow an unauthenticated, physically proximate attacker to achieve arbitrary code execution in the TrustZone Trusted Execution Environment (TEE) of an affected device. This, for example, affects certain Cisco IP Phone and Wireless IP Phone products before 2021-07-07. Exploitation is possible only when the attacker can disassemble the device in order to control the voltage/current for chip pins."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-22T16:53:32.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-brcm-mxc-jul2021-26LqUZUh"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-33478",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The TrustZone implementation in certain Broadcom MediaxChange firmware could allow an unauthenticated, physically proximate attacker to achieve arbitrary code execution in the TrustZone Trusted Execution Environment (TEE) of an affected device. This, for example, affects certain Cisco IP Phone and Wireless IP Phone products before 2021-07-07. Exploitation is possible only when the attacker can disassemble the device in order to control the voltage/current for chip pins."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-brcm-mxc-jul2021-26LqUZUh",
"refsource": "MISC",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-brcm-mxc-jul2021-26LqUZUh"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-33478",
"datePublished": "2021-07-22T16:53:32.000Z",
"dateReserved": "2021-05-20T00:00:00.000Z",
"dateUpdated": "2024-08-03T23:50:42.938Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-33478",
"date": "2026-11-17",
"epss": "0.00304",
"percentile": "0.2349"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D455DEFE-21EB-4097-80DE-15E64D693B83",
"versionEndExcluding": "14.0\\(1\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8800_series_with_multiplatform_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EAFADE09-8296-4358-B7B2-3A1DB820F942",
"versionEndExcluding": "11.3\\(4\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8811_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A479FA93-5249-4BEE-8FC1-3C9BBC0F8AB4",
"versionEndExcluding": "14.0\\(1\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8811_with_multiplatform_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "90C80E75-CE8A-48A7-9BA9-6F75DBC8DF30",
"versionEndExcluding": "11.3\\(4\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8841_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "30778C3F-B616-428D-A53F-18C6345B8176",
"versionEndExcluding": "14.0\\(1\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8841_with_multiplatform_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5DD84FA6-82D0-4777-8FB9-9B2B09374B0A",
"versionEndExcluding": "11.3\\(4\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8845_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "42F08B4A-7F01-4145-B410-0E85F1CE19D9",
"versionEndExcluding": "14.0\\(1\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8845_with_multiplatform_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1B8B2074-1F1E-4F03-BEAF-960DDA712592",
"versionEndExcluding": "11.3\\(4\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8851_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A1888843-83FC-4DCC-9247-1128920DE996",
"versionEndExcluding": "14.0\\(1\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8851_with_multiplatform_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "15DBBC70-588B-44F8-815B-A63CD19A892D",
"versionEndExcluding": "11.3\\(4\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8861_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C16E5F2C-ADBB-44A7-AAB3-8AF0CD186624",
"versionEndExcluding": "14.0\\(1\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8861_with_multiplatform_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8AEBD7B8-B8E9-454C-814E-706D7F6A19F4",
"versionEndExcluding": "11.3\\(4\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8865_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3E5DB741-7AEC-4BA7-80BB-BC784F849C48",
"versionEndExcluding": "14.0\\(1\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:ip_phone_8865_with_multiplatform_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FC3583AE-9C80-4666-A71A-D2E0ACC0D620",
"versionEndExcluding": "11.3\\(4\\)",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:wireless_ip_phone_8821_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48D89E05-BD89-45E1-9D3C-FCC8B09A3D61",
"versionEndExcluding": "11.0\\(6\\)sr1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The TrustZone implementation in certain Broadcom MediaxChange firmware could allow an unauthenticated, physically proximate attacker to achieve arbitrary code execution in the TrustZone Trusted Execution Environment (TEE) of an affected device. This, for example, affects certain Cisco IP Phone and Wireless IP Phone products before 2021-07-07. Exploitation is possible only when the attacker can disassemble the device in order to control the voltage/current for chip pins."
},
{
"lang": "es",
"value": "La implementaci\u00f3n de TrustZone en determinados firmware de Broadcom MediaxChange, podr\u00eda permitir a un atacante no autenticado y f\u00edsicamente pr\u00f3ximo lograr la ejecuci\u00f3n de c\u00f3digo arbitrario en el TrustZone Trusted Execution Environment (TEE) de un dispositivo afectado. Esto, por ejemplo, afecta a determinados productos Cisco IP Phone y Wireless IP Phone anteriores a 2021-07-07. Una explotaci\u00f3n es posible s\u00f3lo cuando el atacante puede desarmar el dispositivo para controlar el voltaje y corriente de los pines del chip"
}
],
"id": "CVE-2021-33478",
"lastModified": "2024-11-21T06:08:54.437",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-07-22T17:15:09.510",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-brcm-mxc-jul2021-26LqUZUh"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-brcm-mxc-jul2021-26LqUZUh"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T13:59:26+00:00",
"cve": "CVE-2021-33478",
"id": "CVE-2021-33478",
"initial_release_date": "2021-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2021-33478",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-33478.json",
"version": "3"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.