Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-7499 (GCVE-0-2020-7499)
Vulnerability from cvelistv5 – Published: 2020-06-16 19:16 – Updated: 2024-08-04 09:33- CWE-863 - Incorrect Authorization
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | U.motion Servers and Touch Panels (affected versions listed in the security notification) |
Affected:
U.motion Servers and Touch Panels (affected versions listed in the security notification)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.565Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "U.motion Servers and Touch Panels (affected versions listed in the security notification)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "U.motion Servers and Touch Panels (affected versions listed in the security notification)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-19T12:20:51.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7499",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "U.motion Servers and Touch Panels (affected versions listed in the security notification)",
"version": {
"version_data": [
{
"version_value": "U.motion Servers and Touch Panels (affected versions listed in the security notification)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-863: Incorrect Authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7499",
"datePublished": "2020-06-16T19:16:53.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:33:19.565Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-7499",
"date": "2026-06-30",
"epss": "0.00783",
"percentile": "0.51417"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-7499\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2020-06-16T20:15:14.770\",\"lastModified\":\"2024-11-21T05:37:15.883\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes.\"},{\"lang\":\"es\",\"value\":\"Una CWE-863: Se presenta una vulnerabilidad de autorizaci\u00f3n incorrecta en U.motion Servers and Touch Panels (versiones afectadas listadas en la notificaci\u00f3n de seguridad) que podr\u00edan causar un acceso no autorizado cuando un usuario poco privilegiado realiza cambios no autorizados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:N/I:P/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mtn6501-0001_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.4.2\",\"matchCriteriaId\":\"B0B3DF18-FE18-4465-8223-8AF2B286746D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mtn6501-0001:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"22E79A6F-C946-43A7-B492-7F3F8CFB18CC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mtn6501-0002_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.4.2\",\"matchCriteriaId\":\"CF40C8EB-9735-43D5-A947-087EFE6AF6F8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mtn6501-0002:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4B17C76A-749C-44DA-8144-51E4328C4768\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mtn6260-0410_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.4.2\",\"matchCriteriaId\":\"AB0811DB-2E4D-4A14-8F87-2C24189D352A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mtn6260-0410:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7D91BDED-9BCF-473A-AB1B-824AA1EDE586\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mtn6260-0415_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.4.2\",\"matchCriteriaId\":\"E369B5A4-1F69-48C1-8C07-0E7C61683EDA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mtn6260-0415:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"436B2EB8-6D93-41FF-BD6E-932D69C4E197\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mtn6260-0310_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.4.2\",\"matchCriteriaId\":\"0176D45B-9007-4558-8D72-B56454EB9733\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mtn6260-0310:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F046097B-B818-4775-A53D-B22F258CB255\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mtn6260-0315_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.4.2\",\"matchCriteriaId\":\"FD29EA41-FA54-45A7-BB61-76D6B1CEF5C4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mtn6260-0315:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9DD21D34-FBBD-4645-8C60-42825281D0FE\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-133-03/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-133-03/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
{
"CVSS 2.0": "AV:N/AC:L/Au:S/C:P/I:C/A:N",
"CVSS 3.0": "AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:H/A:N",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 1.4.2 (MTN6501-0001), \u0434\u043e 1.4.2 (MTN6501-0002), \u0434\u043e 1.4.2 (MTN6260-0410), \u0434\u043e 1.4.2 (MTN6260-0415), \u0434\u043e 1.4.2 (MTN6260-0310), \u0434\u043e 1.4.2 (MTN6260-0315)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2020-133-03_U.motion_Servers_and_Touch_Panels_Notification_V1.2.pdf\u0026p_Doc_Ref=SEVD-2020-133-03",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "12.05.2020",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "02.09.2021",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "02.09.2021",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2021-04332",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2020-7499",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "MTN6501-0001, MTN6501-0002, MTN6260-0410, MTN6260-0415, MTN6260-0310, MTN6260-0315",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0441\u0435\u0440\u0432\u0435\u0440\u043e\u0432 \u0441\u0435\u043d\u0441\u043e\u0440\u043d\u044b\u0445 \u043f\u0430\u043d\u0435\u043b\u0435\u0439 U.motion Servers \u0438Touch Panels, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043e\u0448\u0438\u0431\u043a\u0430\u043c\u0438 \u0430\u0432\u0442\u043e\u0440\u0438\u0437\u0430\u0446\u0438\u0438, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u043e\u043a\u0430\u0437\u0430\u0442\u044c \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043d\u0430 \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u044c \u0434\u0430\u043d\u043d\u044b\u0445",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u0430\u044f \u0430\u0432\u0442\u043e\u0440\u0438\u0437\u0430\u0446\u0438\u044f (CWE-863)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0441\u0435\u0440\u0432\u0435\u0440\u043e\u0432 \u0441\u0435\u043d\u0441\u043e\u0440\u043d\u044b\u0445 \u043f\u0430\u043d\u0435\u043b\u0435\u0439 U.motion Servers \u0438Touch Panels \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043e\u0448\u0438\u0431\u043a\u0430\u043c\u0438 \u0430\u0432\u0442\u043e\u0440\u0438\u0437\u0430\u0446\u0438\u0438. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u043e\u043a\u0430\u0437\u0430\u0442\u044c \u0432\u043e\u0437\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0435 \u043d\u0430 \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u044c \u0434\u0430\u043d\u043d\u044b\u0445",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041d\u0430\u0440\u0443\u0448\u0435\u043d\u0438\u0435 \u0430\u0432\u0442\u043e\u0440\u0438\u0437\u0430\u0446\u0438\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2020-133-03_U.motion_Servers_and_Touch_Panels_Notification_V1.2.pdf\u0026p_Doc_Ref=SEVD-2020-133-03",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u0421\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f, \u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-863",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,5)\n\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 6,3)"
}
CERTFR-2020-AVI-280
Vulnerability from certfr_avis - Published: 2020-05-13 - Updated: 2020-05-13
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un contournement de la politique de sécurité et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | MTN6501-0001 – U.motion – KNX Server versions antérieures à 1.4.2 | ||
| Schneider Electric | N/A | Vijeo Designer versions V6.2 SP9 et antérieures | ||
| Schneider Electric | N/A | MTN6260-0310 – U.Motion KNX Client Touch 10 versions antérieures à 1.4.2 | ||
| Schneider Electric | N/A | MTN6501-0002 – U.Motion – KNX Server Plus versions antérieures à 1.4.2 | ||
| Schneider Electric | N/A | MTN6260-0410 – U.Motion KNX server Plus, Touch 10 versions antérieures à 1.4.2 | ||
| Schneider Electric | N/A | MTN6260-0415 – U.Motion KNX server Plus, Touch 15 versions antérieures à 1.4.2 | ||
| Schneider Electric | N/A | GP-Pro EX versions antérieures à V4.09.120 | ||
| Schneider Electric | N/A | Vijeo Designer Basic versions antérieures à V1.1 HotFix 17 | ||
| Schneider Electric | N/A | MTN6260-0315 – U.Motion KNX Client Touch 15 versions antérieures à 1.4.2 |
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "MTN6501-0001 \u2013 U.motion \u2013 KNX Server versions ant\u00e9rieures \u00e0 1.4.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Vijeo Designer versions V6.2 SP9 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "MTN6260-0310 \u2013 U.Motion KNX Client Touch 10 versions ant\u00e9rieures \u00e0 1.4.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "MTN6501-0002 \u2013 U.Motion \u2013 KNX Server Plus versions ant\u00e9rieures \u00e0 1.4.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "MTN6260-0410 \u2013 U.Motion KNX server Plus, Touch 10 versions ant\u00e9rieures \u00e0 1.4.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "MTN6260-0415 \u2013 U.Motion KNX server Plus, Touch 15 versions ant\u00e9rieures \u00e0 1.4.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "GP-Pro EX versions ant\u00e9rieures \u00e0 V4.09.120",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Vijeo Designer Basic versions ant\u00e9rieures \u00e0 V1.1 HotFix 17",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "MTN6260-0315 \u2013 U.Motion KNX Client Touch 15 versions ant\u00e9rieures \u00e0 1.4.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7500",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7500"
},
{
"name": "CVE-2020-7492",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7492"
},
{
"name": "CVE-2020-7499",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7499"
},
{
"name": "CVE-2020-7501",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7501"
}
],
"initial_release_date": "2020-05-13T00:00:00",
"last_revision_date": "2020-05-13T00:00:00",
"links": [],
"reference": "CERTFR-2020-AVI-280",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-05-13T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un contournement\nde la politique de s\u00e9curit\u00e9 et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-133-02 du 12 mai 2020",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2020-133-02_Vijeo_Designer_and_Vijeo_Designer_Basic_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2020-133-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-133-03 du 12 mai 2020",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2020-133-03_U.motion_Servers_and_Touch_Panels_Notification.pdf\u0026p_Doc_Ref=SEVD-2020-133-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-133-01 du 12 mai 2020",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2020-133-01_Pro-face_GP-ProEX_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2020-133-01"
}
]
}
FKIE_CVE-2020-7499
Vulnerability from fkie_nvd - Published: 2020-06-16 20:15 - Updated: 2026-06-17 03:24{
"affected": [
{
"affectedData": [
{
"product": "U.motion Servers and Touch Panels (affected versions listed in the security notification)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "U.motion Servers and Touch Panels (affected versions listed in the security notification)"
}
]
}
],
"source": "cybersecurity@se.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:mtn6501-0001_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B0B3DF18-FE18-4465-8223-8AF2B286746D",
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:mtn6501-0001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "22E79A6F-C946-43A7-B492-7F3F8CFB18CC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:mtn6501-0002_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CF40C8EB-9735-43D5-A947-087EFE6AF6F8",
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:mtn6501-0002:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B17C76A-749C-44DA-8144-51E4328C4768",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:mtn6260-0410_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AB0811DB-2E4D-4A14-8F87-2C24189D352A",
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:mtn6260-0410:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D91BDED-9BCF-473A-AB1B-824AA1EDE586",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:mtn6260-0415_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E369B5A4-1F69-48C1-8C07-0E7C61683EDA",
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:mtn6260-0415:-:*:*:*:*:*:*:*",
"matchCriteriaId": "436B2EB8-6D93-41FF-BD6E-932D69C4E197",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:mtn6260-0310_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0176D45B-9007-4558-8D72-B56454EB9733",
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:mtn6260-0310:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F046097B-B818-4775-A53D-B22F258CB255",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:mtn6260-0315_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FD29EA41-FA54-45A7-BB61-76D6B1CEF5C4",
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:mtn6260-0315:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9DD21D34-FBBD-4645-8C60-42825281D0FE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes."
},
{
"lang": "es",
"value": "Una CWE-863: Se presenta una vulnerabilidad de autorizaci\u00f3n incorrecta en U.motion Servers and Touch Panels (versiones afectadas listadas en la notificaci\u00f3n de seguridad) que podr\u00edan causar un acceso no autorizado cuando un usuario poco privilegiado realiza cambios no autorizados"
}
],
"id": "CVE-2020-7499",
"lastModified": "2026-06-17T03:24:53.967",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-06-16T20:15:14.770",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-863"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-863"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-GRG5-9RJQ-MRF9
Vulnerability from github – Published: 2022-05-24 17:20 – Updated: 2022-05-24 17:20A CWE-284:Improper Access Control vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes.
{
"affected": [],
"aliases": [
"CVE-2020-7499"
],
"database_specific": {
"cwe_ids": [
"CWE-863"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-06-16T20:15:00Z",
"severity": "MODERATE"
},
"details": "A CWE-284:Improper Access Control vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes.",
"id": "GHSA-grg5-9rjq-mrf9",
"modified": "2022-05-24T17:20:39Z",
"published": "2022-05-24T17:20:39Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-7499"
},
{
"type": "WEB",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03"
}
],
"schema_version": "1.4.0",
"severity": []
}
GSD-2020-7499
Vulnerability from gsd - Updated: 2023-12-13 01:21{
"GSD": {
"alias": "CVE-2020-7499",
"description": "A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes.",
"id": "GSD-2020-7499"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-7499"
],
"details": "A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes.",
"id": "GSD-2020-7499",
"modified": "2023-12-13T01:21:51.935794Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7499",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "U.motion Servers and Touch Panels (affected versions listed in the security notification)",
"version": {
"version_data": [
{
"version_value": "U.motion Servers and Touch Panels (affected versions listed in the security notification)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-863: Incorrect Authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03/"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:mtn6501-0001_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:mtn6501-0001:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:mtn6501-0002_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:mtn6501-0002:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:mtn6260-0410_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:mtn6260-0410:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:mtn6260-0415_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:mtn6260-0415:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:mtn6260-0310_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:mtn6260-0310:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:mtn6260-0315_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:mtn6260-0315:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7499"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-863"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03/",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
},
"lastModifiedDate": "2022-02-03T14:25Z",
"publishedDate": "2020-06-16T20:15Z"
}
}
}
SEVD-2020-133-03
Vulnerability from csaf_se - Published: 2020-05-12 00:00 - Updated: 2021-04-15 00:00A CWE-863: Incorrect Authorization vulnerability exists which could cause unauthorized access when a low privileged user makes unauthorized changes.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric MTN6501-0001 – U.Motion – KNX Server prior to 1.4.2
Schneider Electric / MTN6501-0001 – U.Motion – KNX Server
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric MTN6501-0002 – U.Motion – KNX Server Plus prior to 1.4.2
Schneider Electric / MTN6501-0002 – U.Motion – KNX Server Plus
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric MTN6260-0410 – U.Motion KNX server Plus, Touch 10 prior to 1.4.2
Schneider Electric / MTN6260-0410 – U.Motion KNX server Plus, Touch 10
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric MTN6260-0415 – U.Motion KNX server Plus, Touch 15 prior to 1.4.2
Schneider Electric / MTN6260-0415 – U.Motion KNX server Plus, Touch 15
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric MTN6260-0310 – U.Motion KNX Client Touch 10 prior to 1.4.2
Schneider Electric / MTN6260-0310 – U.Motion KNX Client Touch 10
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric MTN6260-0315 – U.Motion KNX Client Touch 15 prior to 1.4.2
Schneider Electric / MTN6260-0315 – U.Motion KNX Client Touch 15
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric MTN6501-0001 – U.Motion – KNX Server 1.4.2
Schneider Electric / MTN6501-0001 – U.Motion – KNX Server
|
1.4.2 | ||
|
Schneider Electric MTN6501-0002 – U.Motion – KNX Server Plus 1.4.2
Schneider Electric / MTN6501-0002 – U.Motion – KNX Server Plus
|
1.4.2 | ||
|
Schneider Electric MTN6260-0410 – U.Motion KNX server Plus, Touch 10 1.4.2
Schneider Electric / MTN6260-0410 – U.Motion KNX server Plus, Touch 10
|
1.4.2 | ||
|
Schneider Electric MTN6260-0415 – U.Motion KNX server Plus, Touch 15 1.4.2
Schneider Electric / MTN6260-0415 – U.Motion KNX server Plus, Touch 15
|
1.4.2 | ||
|
Schneider Electric MTN6260-0310 – U.Motion KNX Client Touch 10 1.4.2
Schneider Electric / MTN6260-0310 – U.Motion KNX Client Touch 10
|
1.4.2 | ||
|
Schneider Electric MTN6260-0315 – U.Motion KNX Client Touch 15 1.4.2
Schneider Electric / MTN6260-0315 – U.Motion KNX Client Touch 15
|
1.4.2 |
A CWE-89:Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists which could cause arbitrary code to be executed when a malicious command is entered.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric MTN6501-0001 – U.Motion – KNX Server prior to 1.4.2
Schneider Electric / MTN6501-0001 – U.Motion – KNX Server
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric MTN6501-0002 – U.Motion – KNX Server Plus prior to 1.4.2
Schneider Electric / MTN6501-0002 – U.Motion – KNX Server Plus
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric MTN6260-0410 – U.Motion KNX server Plus, Touch 10 prior to 1.4.2
Schneider Electric / MTN6260-0410 – U.Motion KNX server Plus, Touch 10
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric MTN6260-0415 – U.Motion KNX server Plus, Touch 15 prior to 1.4.2
Schneider Electric / MTN6260-0415 – U.Motion KNX server Plus, Touch 15
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric MTN6260-0310 – U.Motion KNX Client Touch 10 prior to 1.4.2
Schneider Electric / MTN6260-0310 – U.Motion KNX Client Touch 10
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric MTN6260-0315 – U.Motion KNX Client Touch 15 prior to 1.4.2
Schneider Electric / MTN6260-0315 – U.Motion KNX Client Touch 15
|
<1.4.2 |
Vendor Fix
fix
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric MTN6501-0001 – U.Motion – KNX Server 1.4.2
Schneider Electric / MTN6501-0001 – U.Motion – KNX Server
|
1.4.2 | ||
|
Schneider Electric MTN6501-0002 – U.Motion – KNX Server Plus 1.4.2
Schneider Electric / MTN6501-0002 – U.Motion – KNX Server Plus
|
1.4.2 | ||
|
Schneider Electric MTN6260-0410 – U.Motion KNX server Plus, Touch 10 1.4.2
Schneider Electric / MTN6260-0410 – U.Motion KNX server Plus, Touch 10
|
1.4.2 | ||
|
Schneider Electric MTN6260-0415 – U.Motion KNX server Plus, Touch 15 1.4.2
Schneider Electric / MTN6260-0415 – U.Motion KNX server Plus, Touch 15
|
1.4.2 | ||
|
Schneider Electric MTN6260-0310 – U.Motion KNX Client Touch 10 1.4.2
Schneider Electric / MTN6260-0310 – U.Motion KNX Client Touch 10
|
1.4.2 | ||
|
Schneider Electric MTN6260-0315 – U.Motion KNX Client Touch 15 1.4.2
Schneider Electric / MTN6260-0315 – U.Motion KNX Client Touch 15
|
1.4.2 |
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in the U.motion servers and touch panel\r\nproducts. ",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "U.motion Servers and Touch Panels - SEVD-2020-133-03 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-133-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2020-133-03_U.motion_Servers_and_Touch_Panels_Notification_V1.2.pdf"
},
{
"category": "self",
"summary": "U.motion Servers and Touch Panels - SEVD-2020-133-03 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-133-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2020-133-03.json"
},
{
"category": "self",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=7EN52-0390\u0026p_enDocType=White+Paper\u0026p_File_Name=Cybersecurity_Best+Practices_EN.pdf"
}
],
"title": "U.motion Servers and Touch Panels",
"tracking": {
"current_release_date": "2021-04-15T00:00:00.000Z",
"generator": {
"date": "2024-12-03T00:00:00.000Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2020-133-03",
"initial_release_date": "2020-05-12T00:00:00.000Z",
"revision_history": [
{
"date": "2020-05-12T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2020-05-19T00:00:00.000Z",
"number": "1.1.0",
"summary": "Updated Acknowledgements section (page 4)."
},
{
"date": "2021-04-15T00:00:00.000Z",
"number": "1.2.0",
"summary": "Updated CWE for CVE-2020-7499"
}
],
"status": "final",
"version": "1.2.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.4.2",
"product": {
"name": "Schneider Electric MTN6501-0001 \u2013 U.Motion \u2013 KNX Server prior to 1.4.2",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "MTN6501-0001 \u2013 U.Motion \u2013 KNX Server"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.4.2",
"product": {
"name": "Schneider Electric MTN6501-0002 \u2013 U.Motion \u2013 KNX Server Plus prior to 1.4.2",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "MTN6501-0002 \u2013 U.Motion \u2013 KNX Server Plus"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.4.2",
"product": {
"name": "Schneider Electric MTN6260-0410 \u2013 U.Motion KNX server Plus, Touch 10 prior to 1.4.2",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "MTN6260-0410 \u2013 U.Motion KNX server Plus, Touch 10"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.4.2",
"product": {
"name": "Schneider Electric MTN6260-0415 \u2013 U.Motion KNX server Plus, Touch 15 prior to 1.4.2",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "MTN6260-0415 \u2013 U.Motion KNX server Plus, Touch 15"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.4.2",
"product": {
"name": "Schneider Electric MTN6260-0310 \u2013 U.Motion KNX Client Touch 10 prior to 1.4.2",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "MTN6260-0310 \u2013 U.Motion KNX Client Touch 10"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.4.2",
"product": {
"name": "Schneider Electric MTN6260-0315 \u2013 U.Motion KNX Client Touch 15 prior to 1.4.2",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "MTN6260-0315 \u2013 U.Motion KNX Client Touch 15"
},
{
"branches": [
{
"category": "product_version",
"name": "1.4.2",
"product": {
"name": "Schneider Electric MTN6501-0001 \u2013 U.Motion \u2013 KNX Server 1.4.2",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "MTN6501-0001 \u2013 U.Motion \u2013 KNX Server"
},
{
"branches": [
{
"category": "product_version",
"name": "1.4.2",
"product": {
"name": "Schneider Electric MTN6501-0002 \u2013 U.Motion \u2013 KNX Server Plus 1.4.2",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "MTN6501-0002 \u2013 U.Motion \u2013 KNX Server Plus"
},
{
"branches": [
{
"category": "product_version",
"name": "1.4.2",
"product": {
"name": "Schneider Electric MTN6260-0410 \u2013 U.Motion KNX server Plus, Touch 10 1.4.2",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "MTN6260-0410 \u2013 U.Motion KNX server Plus, Touch 10"
},
{
"branches": [
{
"category": "product_version",
"name": "1.4.2",
"product": {
"name": "Schneider Electric MTN6260-0415 \u2013 U.Motion KNX server Plus, Touch 15 1.4.2",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "MTN6260-0415 \u2013 U.Motion KNX server Plus, Touch 15"
},
{
"branches": [
{
"category": "product_version",
"name": "1.4.2",
"product": {
"name": "Schneider Electric MTN6260-0310 \u2013 U.Motion KNX Client Touch 10 1.4.2",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "MTN6260-0310 \u2013 U.Motion KNX Client Touch 10"
},
{
"branches": [
{
"category": "product_version",
"name": "1.4.2",
"product": {
"name": "Schneider Electric MTN6260-0315 \u2013 U.Motion KNX Client Touch 15 1.4.2",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "MTN6260-0315 \u2013 U.Motion KNX Client Touch 15"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Zhu Jiaqi"
]
}
],
"cve": "CVE-2020-7499",
"cwe": {
"id": "CWE-863",
"name": "Incorrect Authorization"
},
"notes": [
{
"category": "description",
"text": "A CWE-863: Incorrect Authorization vulnerability exists which could cause unauthorized access\r\nwhen a low privileged user makes unauthorized changes.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"7",
"8",
"9",
"10",
"11",
"12"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "MTN6501-0001 \u2013 U.motion \u2013 KNX Server\r\nhttps://www.se.com/ww/en/product/MTN6501\r\n-0001/u.motion---knx-server/ ",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6501-0001/u.motion---knx-server/?range=61124-u.motion\u0026node=827505925-server\u0026parent-category-id=2200\u0026parent-subcategory-id=88006#pdp-software"
},
{
"category": "vendor_fix",
"details": "MTN6501-0002 \u2013 U.Motion \u2013 KNX Server \r\nPlus \r\nhttps://www.se.com/ww/en/product/MTN6501\r\n-0002/u.motion---knx-server-plus/",
"product_ids": [
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6501-0002/u.motion---knx-server-plus/?range=61124-u.motion\u0026node=827505925-server\u0026parent-category-id=2200\u0026parent-subcategory-id=88006#pdp-software"
},
{
"category": "vendor_fix",
"details": "MTN6260-0410 \u2013 U.Motion KNX server Plus, \r\nTouch 10\r\nhttps://www.se.com/ww/en/product/MTN6260\r\n-0410/",
"product_ids": [
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6260-0410/u.motion-knx-server-plus,-touch-10/#pdp-software"
},
{
"category": "vendor_fix",
"details": "MTN6260-0415 \u2013 U.Motion KNX server Plus, \r\nTouch 15\r\nhttps://www.se.com/ww/en/product/MTN6260\r\n-0415/",
"product_ids": [
"4"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6260-0415/u.motion-knx-server-plus,-touch-15/#pdp-software"
},
{
"category": "vendor_fix",
"details": "MTN6260-0310 \u2013 U.Motion KNX Client \r\nTouch 10\r\nhttps://www.se.com/ww/en/product/MTN6260\r\n-0310/",
"product_ids": [
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6260-0310/u.motion-client-touch-10/#pdp-software"
},
{
"category": "vendor_fix",
"details": "MTN6260-0315 \u2013 U.Motion KNX Client \r\nTouch 15\r\nhttps://www.se.com/ww/en/product/MTN6260\r\n-0315/ ",
"product_ids": [
"6"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6260-0315/u.motion-client-touch-15/#pdp-software"
},
{
"category": "mitigation",
"details": "The following workarounds and mitigations can be applied by customers to reduce the risk:\r\n\u2022 Do not allow direct internet access to the U.motion servers and touch panels. \r\n\u2022 Keep the U.motion servers and touch panels behind a firewall.\r\n",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 6.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:H/A:N",
"version": "3.0"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2020-7499"
},
{
"acknowledgments": [
{
"names": [
"Rgod"
],
"organization": "TrendMicro\u2019s Zero Day Initiative"
}
],
"cve": "CVE-2020-7500",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-89:Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL \r\nInjection\u0027) vulnerability exists which could cause arbitrary code to be executed when a malicious \r\ncommand is entered.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"7",
"8",
"9",
"10",
"11",
"12"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "MTN6501-0001 \u2013 U.motion \u2013 KNX Server\r\nhttps://www.se.com/ww/en/product/MTN6501\r\n-0001/u.motion---knx-server/ ",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6501-0001/u.motion---knx-server/?range=61124-u.motion\u0026node=827505925-server\u0026parent-category-id=2200\u0026parent-subcategory-id=88006#pdp-software"
},
{
"category": "vendor_fix",
"details": "MTN6501-0002 \u2013 U.Motion \u2013 KNX Server \r\nPlus \r\nhttps://www.se.com/ww/en/product/MTN6501\r\n-0002/u.motion---knx-server-plus/",
"product_ids": [
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6501-0002/u.motion---knx-server-plus/?range=61124-u.motion\u0026node=827505925-server\u0026parent-category-id=2200\u0026parent-subcategory-id=88006#pdp-software"
},
{
"category": "vendor_fix",
"details": "MTN6260-0410 \u2013 U.Motion KNX server Plus, \r\nTouch 10\r\nhttps://www.se.com/ww/en/product/MTN6260\r\n-0410/",
"product_ids": [
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6260-0410/u.motion-knx-server-plus,-touch-10/#pdp-software"
},
{
"category": "vendor_fix",
"details": "MTN6260-0415 \u2013 U.Motion KNX server Plus, \r\nTouch 15\r\nhttps://www.se.com/ww/en/product/MTN6260\r\n-0415/",
"product_ids": [
"4"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6260-0415/u.motion-knx-server-plus,-touch-15/#pdp-software"
},
{
"category": "vendor_fix",
"details": "MTN6260-0310 \u2013 U.Motion KNX Client \r\nTouch 10\r\nhttps://www.se.com/ww/en/product/MTN6260\r\n-0310/",
"product_ids": [
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6260-0310/u.motion-client-touch-10/#pdp-software"
},
{
"category": "vendor_fix",
"details": "MTN6260-0315 \u2013 U.Motion KNX Client \r\nTouch 15\r\nhttps://www.se.com/ww/en/product/MTN6260\r\n-0315/ ",
"product_ids": [
"6"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product/MTN6260-0315/u.motion-client-touch-15/#pdp-software"
},
{
"category": "mitigation",
"details": "The following workarounds and mitigations can be applied by customers to reduce the risk:\r\n\u2022 Do not allow direct internet access to the U.motion servers and touch panels. \r\n\u2022 Keep the U.motion servers and touch panels behind a firewall.\r\n",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 6.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 6.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L",
"version": "3.0"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2020-7500"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.