Vulnerability from cvelistv5 – Published: 2021-01-12 00:00 – Updated: 2024-08-04 16:33- CWE-321 - Use of Hard-coded Cryptographic Key
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Siemens | SCALANCE X-200RNA switch family |
Affected:
All versions < V3.2.7
|
guessed | |
| Siemens | SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) |
Affected:
All versions < V4.1.0
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:33:59.028Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE X-200RNA switch family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.7"
}
]
},
{
"product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.0). Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321: Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-13T00:00:00.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-28395",
"datePublished": "2021-01-12T00:00:00.000Z",
"dateReserved": "2020-11-10T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:33:59.028Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-28395",
"date": "2026-11-15",
"epss": "0.0119",
"percentile": "0.6846"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DAB9BF3B-08CB-4307-8EA4-4704E5E107A6",
"versionEndExcluding": "4.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
"matchCriteriaId": "36C9AE74-4683-4ED0-A605-3A6B065C230E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7C7F2ADB-BC8F-480C-B3DB-7CBFFFF6604C",
"versionEndExcluding": "4.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4356417E-B4CB-45B0-B395-CE9D423FAB44",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5637F52B-0887-469D-A6CD-C54996FD09D6",
"versionEndExcluding": "4.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F952542-6B79-4681-A236-15C188AAEB1E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "19EC397D-1510-4F92-94E1-7E154B1FCE1C",
"versionEndExcluding": "4.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
"matchCriteriaId": "664D9C76-BC13-4874-939C-A8211DA33903",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5051EBA9-94F8-4655-8D6C-D991C4348409",
"versionEndExcluding": "4.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4834A67B-7B0B-4F88-BBFB-25667FD68EC5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E3AC6D32-1EDD-4DF1-B48A-D8AE73C0CA2F",
"versionEndExcluding": "4.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E767C461-8FA6-4700-98CB-734AFD309140",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A82CF7F5-5555-4247-9C66-48AC6E3683CC",
"versionEndExcluding": "4.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD19EFB-12D2-4401-B87A-91873528E474",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D9C73FC3-0179-418C-A5F2-E9E51D77D8B1",
"versionEndExcluding": "4.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A5B7DEDC-66BD-4701-BBDD-16273263ADC9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.0). Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en la familia de switch SCALANCE X-300 (incluidas las variantes X408 y SIPLUS NET) (todas las versiones anteriores a V4.1.0).\u0026#xa0;Los dispositivos no crean una nueva clave privada \u00fanica despu\u00e9s del restablecimiento de f\u00e1brica.\u0026#xa0;Un atacante podr\u00eda aprovechar esta situaci\u00f3n en una situaci\u00f3n de man-in-the-middle y descifrar el tr\u00e1fico capturado previamente"
}
],
"id": "CVE-2020-28395",
"lastModified": "2024-11-21T05:22:42.987",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-01-12T21:15:18.197",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"US Government Resource",
"Vendor Advisory"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource",
"Vendor Advisory"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-321"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.