CVE-2019-6810 (GCVE-0-2019-6810)
Vulnerability from cvelistv5 – Published: 2019-09-17 19:52 – Updated: 2024-08-04 20:31
VLAI?
Summary
CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric SE | BMXNOR0200H Ethernet / Serial RTU module |
Affected:
all firmware versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.285Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://security.cse.iitk.ac.in/responsible-disclosure"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "BMXNOR0200H Ethernet / Serial RTU module",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-02T12:10:29",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://security.cse.iitk.ac.in/responsible-disclosure"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6810",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "BMXNOR0200H Ethernet / Serial RTU module",
"version": {
"version_data": [
{
"version_value": "all firmware versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/"
},
{
"name": "https://security.cse.iitk.ac.in/responsible-disclosure",
"refsource": "MISC",
"url": "https://security.cse.iitk.ac.in/responsible-disclosure"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6810",
"datePublished": "2019-09-17T19:52:38",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.285Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2019-6810\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2019-09-17T20:15:11.860\",\"lastModified\":\"2024-11-21T04:47:12.243\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.\"},{\"lang\":\"es\",\"value\":\"CWE-284: Existe una vulnerabilidad de Control de Acceso Inapropiada en el m\u00f3dulo BMXNOR0200H Ethernet/Serial RTU (todas las versiones de firmware), lo que podr\u00eda causar la ejecuci\u00f3n de comandos por parte de usuarios no autorizados al utilizar el protocolo IEC 60870-5-104.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AECF5778-C5F5-4789-BD3D-793B35DDDBDF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"60D9A366-3394-4275-B884-AE6E7227156E\"}]}]}],\"references\":[{\"url\":\"https://security.cse.iitk.ac.in/responsible-disclosure\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.cse.iitk.ac.in/responsible-disclosure\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…