Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2018-7239 (GCVE-0-2018-7239)
Vulnerability from cvelistv5 – Published: 2018-03-09 23:00 – Updated: 2024-09-16 23:21- DLL Hijacking
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02 | x_refsource_MISC |
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/103338 | vdb-entryx_refsource_BID |
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | SoMove |
Affected:
n/a
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:24:11.489Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
},
{
"name": "103338",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103338"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SoMove",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-03-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "DLL Hijacking",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-12T16:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
},
{
"name": "103338",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103338"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-03-01T00:00:00",
"ID": "CVE-2018-7239",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMove",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DLL Hijacking"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
},
{
"name": "103338",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103338"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7239",
"datePublished": "2018-03-09T23:00:00.000Z",
"dateReserved": "2018-02-19T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:21:36.267Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2018-7239",
"date": "2026-06-04",
"epss": "0.00457",
"percentile": "0.64262"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-7239\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2018-03-09T23:29:00.967\",\"lastModified\":\"2024-11-21T04:11:51.273\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de secuestro de DLL en SoMove Software de Schneider Electric y en los componentes de software DTM asociados, en todas las versiones anteriores a la 2.6.2. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo arbitrario.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-426\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv_lift_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"8F0F8212-5CC6-4EB7-9F37-4587FC849A54\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv12_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"70DDF782-E80B-41A6-88F0-52D3BCCD0BE6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv212_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"8A9E382F-DBB4-4B24-81C7-EE33B5248935\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv31_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"2429408E-48C9-4F97-A918-4DDECF6A7AB2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv312_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"44D79762-E0D3-4DB9-8DD8-AE6A93953411\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv32_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"DC70CB2D-2AA8-40EC-97BC-0527D5F100ED\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv320_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.1.6\",\"matchCriteriaId\":\"1D1862C8-5571-4DAC-B9F0-96DC3F2F846F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv340_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.2.3\",\"matchCriteriaId\":\"CB77B51C-CA0B-4C6E-91D2-41C450C6214E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv600_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.8.0\",\"matchCriteriaId\":\"FE8C39E7-A682-4453-945F-D1DFC9418A7C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv61_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"988EB546-BB63-4DEF-800E-5C5A3C796163\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv71_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"848353C2-B49E-4B88-A57A-C783BF47C84C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv900_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.3.5\",\"matchCriteriaId\":\"3BA8B718-4947-41FE-9DDC-DA3AB85992B3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:somove:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.2\",\"matchCriteriaId\":\"AD8AD349-3536-4244-8D10-D860A5A7F1FF\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/103338\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/103338\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
目前厂商已经发布了升级补丁以修复此安全问题,补丁获取链接: https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/
| Name | ['Schneider Electric Altivar Dtm Library <12.7.0', 'Schneider Electric SoMove software <2.6.2'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2018-7239"
}
},
"description": "SoMove software\u662f\u4e13\u4e3a\u65bd\u8010\u5907\u53d8\u9891\u5668\u7528\u6237\u6253\u9020\u7684\u4e00\u6b3e\u5b9e\u7528\u8bbe\u7f6e\u548c\u8c03\u9891\u8f6f\u4ef6\uff0cAltivar Dtm Library\u662f\u4e00\u4e2a\u514d\u8d39\u7684\u5e93\uff0c\u53ef\u63d0\u4f9b\u5404\u79cdDTM\u8bbe\u5907\u7684\u652f\u6301\u3002\r\n\r\nSchneider Electric SoMove software and DTM software\u5b58\u5728DLL\u52ab\u6301\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u6267\u884c\u5df2\u653e\u7f6e\u5728\u641c\u7d22\u8def\u5f84\u4e2d\u7684\u6076\u610fDLL\u6587\u4ef6\u3002",
"discovererName": "ADLab",
"formalWay": "\u76ee\u524d\u5382\u5546\u5df2\u7ecf\u53d1\u5e03\u4e86\u5347\u7ea7\u8865\u4e01\u4ee5\u4fee\u590d\u6b64\u5b89\u5168\u95ee\u9898\uff0c\u8865\u4e01\u83b7\u53d6\u94fe\u63a5\uff1a \r\nhttps://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2018-04780",
"openTime": "2018-03-09",
"patchDescription": "SoMove software\u662f\u4e13\u4e3a\u65bd\u8010\u5907\u53d8\u9891\u5668\u7528\u6237\u6253\u9020\u7684\u4e00\u6b3e\u5b9e\u7528\u8bbe\u7f6e\u548c\u8c03\u9891\u8f6f\u4ef6\uff0cAltivar Dtm Library\u662f\u4e00\u4e2a\u514d\u8d39\u7684\u5e93\uff0c\u53ef\u63d0\u4f9b\u5404\u79cdDTM\u8bbe\u5907\u7684\u652f\u6301\u3002\r\n\r\nSchneider Electric SoMove software and DTM software\u5b58\u5728DLL\u52ab\u6301\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u6267\u884c\u5df2\u653e\u7f6e\u5728\u641c\u7d22\u8def\u5f84\u4e2d\u7684\u6076\u610fDLL\u6587\u4ef6\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric SoMove software and DTM software DLL\u52ab\u6301\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Schneider Electric Altivar Dtm Library \u003c12.7.0",
"Schneider Electric SoMove software \u003c2.6.2"
]
},
"referenceLink": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02",
"serverity": "\u9ad8",
"submitTime": "2018-03-09",
"title": "Schneider Electric SoMove software and DTM software DLL\u52ab\u6301\u6f0f\u6d1e"
}
FKIE_CVE-2018-7239
Vulnerability from fkie_nvd - Published: 2018-03-09 23:29 - Updated: 2024-11-21 04:11| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | http://www.securityfocus.com/bid/103338 | Third Party Advisory, VDB Entry | |
| cybersecurity@se.com | https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02 | Third Party Advisory, US Government Resource | |
| cybersecurity@se.com | https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/103338 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/ | Vendor Advisory |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:atv_lift_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8F0F8212-5CC6-4EB7-9F37-4587FC849A54",
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:atv12_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "70DDF782-E80B-41A6-88F0-52D3BCCD0BE6",
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:atv212_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8A9E382F-DBB4-4B24-81C7-EE33B5248935",
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:atv31_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2429408E-48C9-4F97-A918-4DDECF6A7AB2",
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:atv312_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "44D79762-E0D3-4DB9-8DD8-AE6A93953411",
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:atv32_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DC70CB2D-2AA8-40EC-97BC-0527D5F100ED",
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:atv320_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1D1862C8-5571-4DAC-B9F0-96DC3F2F846F",
"versionEndExcluding": "1.1.6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:atv340_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CB77B51C-CA0B-4C6E-91D2-41C450C6214E",
"versionEndExcluding": "1.2.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:atv600_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE8C39E7-A682-4453-945F-D1DFC9418A7C",
"versionEndExcluding": "1.8.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:atv61_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "988EB546-BB63-4DEF-800E-5C5A3C796163",
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:atv71_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "848353C2-B49E-4B88-A57A-C783BF47C84C",
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:atv900_dtm:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3BA8B718-4947-41FE-9DDC-DA3AB85992B3",
"versionEndExcluding": "1.3.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:somove:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AD8AD349-3536-4244-8D10-D860A5A7F1FF",
"versionEndExcluding": "2.6.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de secuestro de DLL en SoMove Software de Schneider Electric y en los componentes de software DTM asociados, en todas las versiones anteriores a la 2.6.2. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo arbitrario."
}
],
"id": "CVE-2018-7239",
"lastModified": "2024-11-21T04:11:51.273",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-03-09T23:29:00.967",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/103338"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/103338"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-426"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-98P4-3PV5-4M4W
Vulnerability from github – Published: 2022-05-14 03:35 – Updated: 2022-05-14 03:35A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.
{
"affected": [],
"aliases": [
"CVE-2018-7239"
],
"database_specific": {
"cwe_ids": [
"CWE-426"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2018-03-09T23:29:00Z",
"severity": "HIGH"
},
"details": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.",
"id": "GHSA-98p4-3pv5-4m4w",
"modified": "2022-05-14T03:35:50Z",
"published": "2022-05-14T03:35:50Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-7239"
},
{
"type": "WEB",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
},
{
"type": "WEB",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01"
},
{
"type": "WEB",
"url": "http://www.securityfocus.com/bid/103338"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2018-7239
Vulnerability from gsd - Updated: 2023-12-13 01:22{
"GSD": {
"alias": "CVE-2018-7239",
"description": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.",
"id": "GSD-2018-7239"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2018-7239"
],
"details": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.",
"id": "GSD-2018-7239",
"modified": "2023-12-13T01:22:33.217124Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-03-01T00:00:00",
"ID": "CVE-2018-7239",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMove",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DLL Hijacking"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
},
{
"name": "103338",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103338"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv32_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv71_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv61_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv_lift_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:somove:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.6.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv340_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.2.3",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv900_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.3.5",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv31_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv212_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv320_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.1.6",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv600_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.8.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv312_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "12.7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:atv12_dtm:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "12.7.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7239"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-426"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
},
{
"name": "103338",
"refsource": "BID",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/103338"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
}
]
}
},
"impact": {
"baseMetricV2": {
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2018-03-26T15:22Z",
"publishedDate": "2018-03-09T23:29Z"
}
}
}
ICSA-18-065-02
Vulnerability from csaf_cisa - Published: 2018-03-06 00:00 - Updated: 2018-03-06 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
ATV6xx DTM: versions prior to 1.8.0
Schneider Electric Software, LLC / ATV6xx DTM
|
< 1.8.0 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
ATV340 DTM: versions prior to 1.2.3
Schneider Electric Software, LLC / ATV340 DTM
|
< 1.2.3 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
ATV12 DTM: versions prior to 12.7.0
Schneider Electric Software, LLC / ATV12 DTM
|
< 12.7.0 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
ATV32 DTM: versions prior to 12.7.0
Schneider Electric Software, LLC / ATV32 DTM
|
< 12.7.0 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
ATV320 DTM: versions prior to 1.1.6
Schneider Electric Software, LLC / ATV320 DTM
|
< 1.1.6 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
ATV31/312 DTM: versions prior to 12.7.0
Schneider Electric Software, LLC / ATV31/312 DTM
|
< 12.7.0 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
AltivarDtmLibrary: versions prior to 12.7.0
Schneider Electric Software, LLC / AltivarDtmLibrary
|
< 12.7.0 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
ATV9xx DTM: versions prior to 1.3.5
Schneider Electric Software, LLC / ATV9xx DTM
|
< 1.3.5 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
ATV212 DTM: versions prior to 12.7.0
Schneider Electric Software, LLC / ATV212 DTM
|
< 12.7.0 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
ATV71 DTM: versions prior to 12.7.0
Schneider Electric Software, LLC / ATV71 DTM
|
< 12.7.0 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
ATV61 DTM: versions prior to 12.7.0
Schneider Electric Software, LLC / ATV61 DTM
|
< 12.7.0 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
ATV LIFT DTM: versions prior to 12.7.0
Schneider Electric Software, LLC / ATV LIFT DTM
|
< 12.7.0 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
|
|
SoMove software: versions prior to 2.6.2
Schneider Electric Software, LLC / SoMove software
|
< 2.6.2 |
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Vendor Fix
fix
Mitigation
fix
Mitigation
fix
|
{
"document": {
"acknowledgments": [
{
"names": [
"ADLab"
],
"organization": "Venustech",
"summary": "reporting this vulnerability to NCCIC"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Vendor: Schneider Electric",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Critical manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerabilityby protecting themselves from social engineering attacks. Specifically, users should: Do not click web links or open unsolicited attachments in email messages; Refer to Recognizing and Avoiding Email Scams (https://www.cisa.gov/reading_room/emailscams_0905.pdf) for more information on avoiding email scams; Refer to Avoiding Social Engineering and Phishing Attacks (https://www.cisa.gov/cas/tips/ST04-014.html) for more information on social engineering attacks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available in the NCCIC Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT website.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. Low skill level is needed to exploit.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-18-065-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-065-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-18-065-02 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-065-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/"
}
],
"title": "Schneider Electric SoMove Software and DTM Software Components",
"tracking": {
"current_release_date": "2018-03-06T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-18-065-02",
"initial_release_date": "2018-03-06T00:00:00.000000Z",
"revision_history": [
{
"date": "2018-03-06T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-18-065-02 Schneider Electric SoMove Software and DTM Software Components"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 1.8.0",
"product": {
"name": "ATV6xx DTM: versions prior to 1.8.0",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "ATV6xx DTM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 1.2.3",
"product": {
"name": "ATV340 DTM: versions prior to 1.2.3",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "ATV340 DTM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 12.7.0",
"product": {
"name": "ATV12 DTM: versions prior to 12.7.0",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "ATV12 DTM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 12.7.0",
"product": {
"name": "ATV32 DTM: versions prior to 12.7.0",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "ATV32 DTM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 1.1.6",
"product": {
"name": "ATV320 DTM: versions prior to 1.1.6",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "ATV320 DTM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 12.7.0",
"product": {
"name": "ATV31/312 DTM: versions prior to 12.7.0",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "ATV31/312 DTM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 12.7.0",
"product": {
"name": "AltivarDtmLibrary: versions prior to 12.7.0",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "AltivarDtmLibrary"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 1.3.5",
"product": {
"name": "ATV9xx DTM: versions prior to 1.3.5",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "ATV9xx DTM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 12.7.0",
"product": {
"name": "ATV212 DTM: versions prior to 12.7.0",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "ATV212 DTM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 12.7.0",
"product": {
"name": "ATV71 DTM: versions prior to 12.7.0",
"product_id": "CSAFPID-00010"
}
}
],
"category": "product_name",
"name": "ATV71 DTM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 12.7.0",
"product": {
"name": "ATV61 DTM: versions prior to 12.7.0",
"product_id": "CSAFPID-00011"
}
}
],
"category": "product_name",
"name": "ATV61 DTM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 12.7.0",
"product": {
"name": "ATV LIFT DTM: versions prior to 12.7.0",
"product_id": "CSAFPID-00012"
}
}
],
"category": "product_name",
"name": "ATV LIFT DTM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 2.6.2",
"product": {
"name": "SoMove software: versions prior to 2.6.2",
"product_id": "CSAFPID-00013"
}
}
],
"category": "product_name",
"name": "SoMove software"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2018-7239",
"cwe": {
"id": "CWE-427",
"name": "Uncontrolled Search Path Element"
},
"notes": [
{
"category": "summary",
"text": "An attacker may execute malicious DLL files that have been placed within the search path. CVE-2018-7239 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7239"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "SoMove Software\u2014SoMove_V2.6.3",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://www.schneider-electric.com/en/download/document/SoMove_FDT/"
},
{
"category": "vendor_fix",
"details": "ATV320 DTM\u2014Schneider_Electric_Altivar_Machine_ATV320_DTM_Library_V1.1.6",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://www.schneider-electric.com/en/download/document/ATV320_DTM_Library/"
},
{
"category": "vendor_fix",
"details": "ATV340 DTM\u2014Schneider_Electric_Altivar_Machine_ATV340_DTM_Library_V1.2.3",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://www.schneider-electric.com/en/download/document/ATV340_DTM_LibraryEN/"
},
{
"category": "vendor_fix",
"details": "ATV6XX DTM\u2014Schneider_Electric_Altivar_Process_ATV6xx_DTM_Library_V1.8.0",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://www.schneider-electric.com/en/download/document/ATV6xx_DTM_Library_EN/"
},
{
"category": "vendor_fix",
"details": "ATV9XX DTM\u2014Schneider-Electric-Altivar-Process-ATV9xx-DTM-Library-V1.3.5",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://www.schneider-electric.com/en/download/document/ATV9xx_DTM_Library_EN/"
},
{
"category": "vendor_fix",
"details": "ATV32 / ATV71 / ATV61 / ATV LIFT / ATV31_312 / ATV212 / ATV12 AltivarDtmLibraryV12.7.0",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://www.schneider-electric.com/en/download/document/Altivar_DTM_Library/"
},
{
"category": "mitigation",
"details": "For more information on this vulnerability and its associated patches, please see Schneider Electric\u0027s security notification SEVD-2018-060-01 on their website",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
},
{
"category": "mitigation",
"details": "For further information related to cybersecurity in Schneider Electric products, please visit the company\u0027s cybersecurity web page",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
}
]
}
]
}
VAR-201803-1846
Vulnerability from variot - Updated: 2024-11-23 23:05A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code. Schneider Electric SoMove Software and DTM A software component contains an unreliable search path vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SoMove software is a practical setup and FM software for users of Schneider inverters. The Altivar Dtm Library is a free library that supports a wide range of DTM devices. Multiple Schneider Electric Products are prone to local arbitrary code-execution vulnerability because it fails to sanitize user-supplied input. A remote attacker can leverage this issue to execute arbitrary code in the context of the affected application. Failed exploit attempts will result in a denial of service condition. The following products are affected: SoMove software versions prior to 2.6.2 ATV320 DTM versions prior to 1.1.6 ATV340 DTM versions prior to 1.2.3 ATV6xx DTM versions prior to 1.8.0 ATV9xx DTM versions prior to 1.3.5 AltivarDtmLibrary versions prior to 12.7.0. are all products of French Schneider Electric (Schneider Electric). ATV320 DTM is a device type manager
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201803-1846",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "atv340 dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "1.2.3"
},
{
"model": "atv312 dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "12.7.0"
},
{
"model": "atv32 dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "12.7.0"
},
{
"model": "atv71 dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "12.7.0"
},
{
"model": "atv900 dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "1.3.5"
},
{
"model": "atv600 dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "1.8.0"
},
{
"model": "somove",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "2.6.2"
},
{
"model": "atv12 dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "12.7.0"
},
{
"model": "atv31 dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "12.7.0"
},
{
"model": "atv212 dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "12.7.0"
},
{
"model": "atv320 dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "1.1.6"
},
{
"model": "atv lift dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "12.7.0"
},
{
"model": "atv61 dtm",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "12.7.0"
},
{
"model": "atv lift dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "atv12 dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "atv212 dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "atv31 dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "atv312 dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "atv32 dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "atv320 dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "atv340 dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "atv61 dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "atv6xx dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "atv71 dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "atv9xx dtm",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "somove",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "electric altivar dtm library",
"scope": "lt",
"trust": 0.6,
"vendor": "schneider",
"version": "12.7.0"
},
{
"model": "electric somove software",
"scope": "lt",
"trust": 0.6,
"vendor": "schneider",
"version": "2.6.2"
},
{
"model": "somove",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider electric",
"version": "1.7"
},
{
"model": "somove software",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "atv9xx dtm",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "atv71 dtm",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "atv6xx dtm",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "atv61 dtm",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "atv340 dtm",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "atv320 dtm",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "atv32 dtm",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "atv31/312 dtm",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "atv212 dtm",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "atv12 dtm",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "atv lift dtm",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "altivardtmlibrary",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "0"
},
{
"model": "somove software",
"scope": "ne",
"trust": 0.3,
"vendor": "schneider electric",
"version": "2.6.2"
},
{
"model": "atv9xx dtm",
"scope": "ne",
"trust": 0.3,
"vendor": "schneider electric",
"version": "1.3.5"
},
{
"model": "atv6xx dtm",
"scope": "ne",
"trust": 0.3,
"vendor": "schneider electric",
"version": "1.8"
},
{
"model": "atv340 dtm",
"scope": "ne",
"trust": 0.3,
"vendor": "schneider electric",
"version": "1.2.3"
},
{
"model": "atv320 dtm",
"scope": "ne",
"trust": 0.3,
"vendor": "schneider electric",
"version": "1.1.6"
},
{
"model": "altivardtmlibrary",
"scope": "ne",
"trust": 0.3,
"vendor": "schneider electric",
"version": "12.7"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv12 dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv212 dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv312 dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv31 dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv320 dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv32 dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv340 dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv600 dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv61 dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv71 dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv900 dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "atv lift dtm",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "somove",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "e2e4d830-39ab-11e9-9905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-04780"
},
{
"db": "BID",
"id": "103338"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002540"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-274"
},
{
"db": "NVD",
"id": "CVE-2018-7239"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:schneider_electric:atv_lift_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:atv12_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:atv212_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:atv31_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:atv312_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:atv32_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:atv320_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:atv340_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:atv61_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:atv600_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:atv71_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:atv900_dtm",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:somove",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-002540"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "ADLab of Venustech",
"sources": [
{
"db": "BID",
"id": "103338"
}
],
"trust": 0.3
},
"cve": "CVE-2018-7239",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CVE-2018-7239",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2018-04780",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "e2e4d830-39ab-11e9-9905-000c29342cb1",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "VHN-137271",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2018-7239",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-7239",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2018-7239",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2018-04780",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201803-274",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "e2e4d830-39ab-11e9-9905-000c29342cb1",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-137271",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e2e4d830-39ab-11e9-9905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-04780"
},
{
"db": "VULHUB",
"id": "VHN-137271"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002540"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-274"
},
{
"db": "NVD",
"id": "CVE-2018-7239"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code. Schneider Electric SoMove Software and DTM A software component contains an unreliable search path vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SoMove software is a practical setup and FM software for users of Schneider inverters. The Altivar Dtm Library is a free library that supports a wide range of DTM devices. Multiple Schneider Electric Products are prone to local arbitrary code-execution vulnerability because it fails to sanitize user-supplied input. \nA remote attacker can leverage this issue to execute arbitrary code in the context of the affected application. Failed exploit attempts will result in a denial of service condition. \nThe following products are affected:\nSoMove software versions prior to 2.6.2\nATV320 DTM versions prior to 1.1.6\nATV340 DTM versions prior to 1.2.3\nATV6xx DTM versions prior to 1.8.0\nATV9xx DTM versions prior to 1.3.5\nAltivarDtmLibrary versions prior to 12.7.0. are all products of French Schneider Electric (Schneider Electric). ATV320 DTM is a device type manager",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-7239"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002540"
},
{
"db": "CNVD",
"id": "CNVD-2018-04780"
},
{
"db": "BID",
"id": "103338"
},
{
"db": "IVD",
"id": "e2e4d830-39ab-11e9-9905-000c29342cb1"
},
{
"db": "VULHUB",
"id": "VHN-137271"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-7239",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-18-065-02",
"trust": 2.8
},
{
"db": "BID",
"id": "103338",
"trust": 2.0
},
{
"db": "SCHNEIDER",
"id": "SEVD-2018-060-01",
"trust": 1.7
},
{
"db": "CNVD",
"id": "CNVD-2018-04780",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201803-274",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002540",
"trust": 0.8
},
{
"db": "NSFOCUS",
"id": "39055",
"trust": 0.6
},
{
"db": "IVD",
"id": "E2E4D830-39AB-11E9-9905-000C29342CB1",
"trust": 0.2
},
{
"db": "SEEBUG",
"id": "SSVID-99001",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-137271",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e2e4d830-39ab-11e9-9905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-04780"
},
{
"db": "VULHUB",
"id": "VHN-137271"
},
{
"db": "BID",
"id": "103338"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002540"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-274"
},
{
"db": "NVD",
"id": "CVE-2018-7239"
}
]
},
"id": "VAR-201803-1846",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e2e4d830-39ab-11e9-9905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-04780"
},
{
"db": "VULHUB",
"id": "VHN-137271"
}
],
"trust": 1.8166666666666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e2e4d830-39ab-11e9-9905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-04780"
}
]
},
"last_update_date": "2024-11-23T23:05:09.486000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SEVD-2018-060-01",
"trust": 0.8,
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Id=9561606015\u0026p_File_Name=SEVD-2018-060-01+SoMove.pdf\u0026p_Reference=SEVD-2018-060-01"
},
{
"title": "Schneider Electric SoMove software and DTM software DLL hijacking vulnerability patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/120837"
},
{
"title": "Multiple Schneider Electric Product security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=79002"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-04780"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002540"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-274"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-426",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-137271"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002540"
},
{
"db": "NVD",
"id": "CVE-2018-7239"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-18-065-02"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/103338"
},
{
"trust": 1.7,
"url": "https://www.schneider-electric.com/en/download/document/sevd-2018-060-01/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-7239"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-7239"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/39055"
},
{
"trust": 0.3,
"url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-04780"
},
{
"db": "VULHUB",
"id": "VHN-137271"
},
{
"db": "BID",
"id": "103338"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002540"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-274"
},
{
"db": "NVD",
"id": "CVE-2018-7239"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e2e4d830-39ab-11e9-9905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-04780"
},
{
"db": "VULHUB",
"id": "VHN-137271"
},
{
"db": "BID",
"id": "103338"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002540"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-274"
},
{
"db": "NVD",
"id": "CVE-2018-7239"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-03-09T00:00:00",
"db": "IVD",
"id": "e2e4d830-39ab-11e9-9905-000c29342cb1"
},
{
"date": "2018-03-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-04780"
},
{
"date": "2018-03-09T00:00:00",
"db": "VULHUB",
"id": "VHN-137271"
},
{
"date": "2018-03-06T00:00:00",
"db": "BID",
"id": "103338"
},
{
"date": "2018-04-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-002540"
},
{
"date": "2018-03-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201803-274"
},
{
"date": "2018-03-09T23:29:00.967000",
"db": "NVD",
"id": "CVE-2018-7239"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-03-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-04780"
},
{
"date": "2018-03-26T00:00:00",
"db": "VULHUB",
"id": "VHN-137271"
},
{
"date": "2018-03-06T00:00:00",
"db": "BID",
"id": "103338"
},
{
"date": "2018-04-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-002540"
},
{
"date": "2018-03-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201803-274"
},
{
"date": "2024-11-21T04:11:51.273000",
"db": "NVD",
"id": "CVE-2018-7239"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201803-274"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric SoMove software and DTM software DLL Hijacking vulnerability",
"sources": [
{
"db": "IVD",
"id": "e2e4d830-39ab-11e9-9905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-04780"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "lack of information",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201803-274"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.