CVE-2018-7230 (GCVE-0-2018-7230)
Vulnerability from cvelistv5 – Published: 2018-03-09 23:00 – Updated: 2024-09-17 03:07
VLAI
Summary
A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67.
Severity
8.8 (High)
CWE
- XML External Entity Processing
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Pelco Sarix Professional |
Affected:
all firmware versions prior to 3.29.70
|
Date Public
2018-03-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:24:11.129Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Pelco Sarix Professional",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all firmware versions prior to 3.29.70"
}
]
}
],
"datePublic": "2018-03-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric\u0027s Pelco Sarix Professional in all firmware versions prior to 3.29.67."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "XML External Entity Processing",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-09T22:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-03-01T00:00:00",
"ID": "CVE-2018-7230",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Pelco Sarix Professional",
"version": {
"version_data": [
{
"version_value": "all firmware versions prior to 3.29.70"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric\u0027s Pelco Sarix Professional in all firmware versions prior to 3.29.67."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "XML External Entity Processing"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7230",
"datePublished": "2018-03-09T23:00:00.000Z",
"dateReserved": "2018-02-19T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:07:08.626Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2018-7230",
"date": "2026-06-03",
"epss": "0.00342",
"percentile": "0.57124"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-7230\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2018-03-09T23:29:00.483\",\"lastModified\":\"2024-11-21T04:11:50.013\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric\u0027s Pelco Sarix Professional in all firmware versions prior to 3.29.67.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de XEE (XML External Entity) en import.cgi del componente de la interfaz web en Pelco Sarix Professional de Schneider Electric en todas las versiones de firmware anteriores a la 3.29.67.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-611\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mps110-1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"E3EF4EC2-D25E-4EC1-8426-57FE421671CB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mps110-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"778C6B7B-4762-4FAA-820A-FBC8F908E1F9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imps110-1er_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"0665DC91-BE7B-422C-8669-0F954D125555\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imps110-1er:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D366FB62-6A7A-4BD6-BDA4-11931C4EFD81\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:ibps110-1er_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"E8755385-CDAD-48BB-9833-142598406FA1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:ibps110-1er:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5DCEC508-8056-4655-95D6-8FD81FA83B53\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp1110-1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"2BD2C651-6BF4-4A5E-9006-B6683E0FB3F3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp1110-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8585A047-D4D5-4EE9-A839-827D50F28E6F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp1110-1e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"55DE8E5B-B037-4DA5-A41C-1162E57183A0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp1110-1e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0C54ECB2-48E2-4484-BDA3-3B1A2B4F64BA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp1110-1er_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"11A4676C-101D-4E30-AE2B-473DE833415D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp1110-1er:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CCE896FA-E8B0-43AD-B7D6-3606552A927A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:ibp1110-1er_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"DAD29A69-4FAF-4F1C-90F7-75092BD34FA1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:ibp1110-1er:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"43A50B71-9906-4CA8-8CCA-3ABEFE36DDF8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp219-1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"5E8F3C66-8C91-42DA-B3BC-7A799463420B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp219-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A9B0FA60-0C47-4874-BB4E-BD9C5392EE36\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp219-1e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"A8CFD36A-AAAC-4EDA-B073-B5BA771D2F71\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp219-1e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C505935-2601-4858-9107-35ACCA09C5E2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp219-1er_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"71B4BB85-B2E7-4890-B27F-D57C71E1C1DF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp219-1er:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"83F91A7F-DB48-4431-9998-B45B04858905\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:ibp219-1er_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"6228B511-D0D3-42A1-9D1B-259B1DB5C9C4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:ibp219-1er:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E4BE69D-0ED4-41E2-ACBD-F28EFE3F3678\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp319-1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"1D4FBCCA-2E0A-42B9-9BEA-F1AF08C5C3E7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp319-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2AEF2268-8C80-43DE-A26B-D76DEE72A20C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp319-1e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"608DC472-5B55-45A6-AB2D-DC775A6903B1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp319-1e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"679FC4B1-2BAE-42DC-BC98-80F34DC40E57\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:ibp319-1er_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"4D566BF6-12A1-4AFC-B627-C47A87704517\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:ibp319-1er:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EDEA40CA-2138-46EB-AAF6-6F0997D8D9E0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp519-1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"53029C82-C2E9-443A-BE4E-3E6A7C774876\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp519-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5457D7DC-990F-47BA-BDAF-4224B1D8367C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp319-1er_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"C894428E-3ADA-4FE7-B4D3-AC94C297F097\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp319-1er:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2A093D08-9339-4F5E-8DC3-7335F64B0058\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp519-1e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"CA8D3D7B-C9E3-4F81-82EB-E5FB385B8F40\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp519-1e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B9940495-9135-414B-9266-E8ADABDC27B5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imp519-1er_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"D6D3D3D8-B55F-473C-BB96-DAFF37434089\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imp519-1er:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA8B8E07-5ED4-420C-A6B0-62D69BB809BB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:ibp519-1er_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"AAC22F8F-58F4-43E5-B614-52DB1E67EE3F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:ibp519-1er:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D09F722A-5337-4891-A5A2-CAE3B4C562E6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:imps110-1e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.29.67\",\"matchCriteriaId\":\"ACDE10BC-5B87-4737-99BE-3BD018F2B6FF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:imps110-1e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA4F3354-111C-4C4A-88CE-8243BF9A1D26\"}]}]}],\"references\":[{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…