CVE-2013-3959 (GCVE-0-2013-3959)
Vulnerability from cvelistv5 – Published: 2013-06-14 19:00 – Updated: 2024-09-16 20:42- n/a
| URL | Tags |
|---|---|
| http://www.siemens.com/corporate-technology/pool/… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:30:49.314Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-06-14T19:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-3959",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-3959",
"datePublished": "2013-06-14T19:00:00.000Z",
"dateReserved": "2013-06-05T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:42:00.921Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2013-3959",
"date": "2026-07-01",
"epss": "0.01332",
"percentile": "0.67633"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2013-3959\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2013-06-14T19:55:01.270\",\"lastModified\":\"2026-04-29T01:13:23.040\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.\"},{\"lang\":\"es\",\"value\":\"El navegador Web de Siemens WinCC antes de v7.2 Update 1, tal y como se utiliza en SIMATIC PCS7 v8.0 SP1 y anteriores y otros productos, muestra un comportamiento diferente para los nombres de usuario de NetBIOS en funci\u00f3n de si existe o no la cuenta de usuario, lo que permite a usuarios remotos autenticados enumerar nombres de cuenta a trav\u00e9s de par\u00e1metros de la URL modificados a mano.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:*:sp1:*:*:*:*:*:*\",\"versionEndIncluding\":\"8.0\",\"matchCriteriaId\":\"0165209F-7378-4C05-9373-ECA6EA57697D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8B894F4-9635-4436-BC0A-E43280426017\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.2\",\"matchCriteriaId\":\"74484B5D-121B-4838-9072-019532E78A03\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A33F9015-7058-419A-8762-CB2AE4ACF1A7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6271FCC-CCF6-4D31-801A-B4B0DC4639DD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF7A6B2B-D573-4285-B3B4-136F2BE7E710\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"111D0F4D-2B67-46E8-BF8D-5D30EFE561EE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2B16BB99-49E0-443E-BEE0-C7694D2C54E1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.1:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"A4115260-50FC-40C9-81CF-4D9F97394627\"}]}]}],\"references\":[{\"url\":\"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
CERTA-2013-AVI-360
Vulnerability from certfr_avis - Published: 2013-06-18 - Updated: 2013-06-18
De multiples vulnérabilités ont été corrigées dans Siemens WinCC Web Navigator. Elles permettent à un attaquant de provoquer un déni de service, un contournement de la politique de sécurité et une élévation de privilèges.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC PCS7 versions 8.0 SP1 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "WinCC versions 7.2 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2013-3957",
"url": "https://www.cve.org/CVERecord?id=CVE-2013-3957"
},
{
"name": "CVE-2013-3958",
"url": "https://www.cve.org/CVERecord?id=CVE-2013-3958"
},
{
"name": "CVE-2013-3959",
"url": "https://www.cve.org/CVERecord?id=CVE-2013-3959"
}
],
"initial_release_date": "2013-06-18T00:00:00",
"last_revision_date": "2013-06-18T00:00:00",
"links": [],
"reference": "CERTA-2013-AVI-360",
"revisions": [
{
"description": "version initiale.",
"revision_date": "2013-06-18T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 corrig\u00e9es dans \u003cspan\nclass=\"textit\"\u003eSiemens WinCC Web Navigator\u003c/span\u003e. Elles permettent \u00e0 un\nattaquant de provoquer un d\u00e9ni de service, un contournement de la\npolitique de s\u00e9curit\u00e9 et une \u00e9l\u00e9vation de privil\u00e8ges.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans Siemens WinCC Web Navigator",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-345843 du 14 juin 2013",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
}
]
}
FKIE_CVE-2013-3959
Vulnerability from fkie_nvd - Published: 2013-06-14 19:55 - Updated: 2026-06-16 23:56{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs7:*:sp1:*:*:*:*:*:*",
"matchCriteriaId": "0165209F-7378-4C05-9373-ECA6EA57697D",
"versionEndIncluding": "8.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"matchCriteriaId": "E8B894F4-9635-4436-BC0A-E43280426017",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74484B5D-121B-4838-9072-019532E78A03",
"versionEndIncluding": "7.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"matchCriteriaId": "A33F9015-7058-419A-8762-CB2AE4ACF1A7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"matchCriteriaId": "E6271FCC-CCF6-4D31-801A-B4B0DC4639DD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"matchCriteriaId": "DF7A6B2B-D573-4285-B3B4-136F2BE7E710",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*",
"matchCriteriaId": "111D0F4D-2B67-46E8-BF8D-5D30EFE561EE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.1:*:*:*:*:*:*:*",
"matchCriteriaId": "2B16BB99-49E0-443E-BEE0-C7694D2C54E1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.1:sp1:*:*:*:*:*:*",
"matchCriteriaId": "A4115260-50FC-40C9-81CF-4D9F97394627",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters."
},
{
"lang": "es",
"value": "El navegador Web de Siemens WinCC antes de v7.2 Update 1, tal y como se utiliza en SIMATIC PCS7 v8.0 SP1 y anteriores y otros productos, muestra un comportamiento diferente para los nombres de usuario de NetBIOS en funci\u00f3n de si existe o no la cuenta de usuario, lo que permite a usuarios remotos autenticados enumerar nombres de cuenta a trav\u00e9s de par\u00e1metros de la URL modificados a mano."
}
],
"id": "CVE-2013-3959",
"lastModified": "2026-06-16T23:56:05.683",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2013-06-14T19:55:01.270",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-F45G-FR2H-MFP5
Vulnerability from github – Published: 2022-05-17 05:08 – Updated: 2022-05-17 05:08The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.
{
"affected": [],
"aliases": [
"CVE-2013-3959"
],
"database_specific": {
"cwe_ids": [
"CWE-200"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2013-06-14T19:55:00Z",
"severity": "MODERATE"
},
"details": "The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.",
"id": "GHSA-f45g-fr2h-mfp5",
"modified": "2022-05-17T05:08:41Z",
"published": "2022-05-17T05:08:41Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2013-3959"
},
{
"type": "WEB",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
}
],
"schema_version": "1.4.0",
"severity": []
}
GSD-2013-3959
Vulnerability from gsd - Updated: 2023-12-13 01:22{
"GSD": {
"alias": "CVE-2013-3959",
"description": "The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.",
"id": "GSD-2013-3959"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2013-3959"
],
"details": "The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.",
"id": "GSD-2013-3959",
"modified": "2023-12-13T01:22:22.491660Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-3959",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.1:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:*:sp1:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "8.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-3959"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
}
},
"lastModifiedDate": "2013-06-17T04:00Z",
"publishedDate": "2013-06-14T19:55Z"
}
}
}
ICSA-13-169-02
Vulnerability from csaf_cisa - Published: 2013-03-21 06:00 - Updated: 2025-06-06 16:07{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-13-169-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2013/icsa-13-169-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-13-169-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-13-169-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "Siemens WinCC 7.2 Multiple Vulnerabilities",
"tracking": {
"current_release_date": "2025-06-06T16:07:03.931759Z",
"generator": {
"date": "2025-06-06T16:07:03.931730Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-13-169-02",
"initial_release_date": "2013-03-21T06:00:00.000000Z",
"revision_history": [
{
"date": "2013-03-21T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
},
{
"date": "2025-06-06T16:07:03.931759Z",
"legacy_version": "CSAF Conversion",
"number": "2",
"summary": "Advisory converted into a CSAF"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=7.2",
"product": {
"name": "Siemens WinCC: \u003c=7.2",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "WinCC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=V8.0_SP1",
"product": {
"name": "Siemens SIMATIC PCS7: \u003c=V8.0_SP1",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS7"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2013-3957",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Siemens has produced a software update that resolves these vulnerabilities. The update can be applied to all versions of WinCC Web Navigator starting with Version 7.2. Siemens recommends that asset owners and operators contact Siemens customer support to acquire the update.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Siemens update information is located here: (http://support.automation.siemens.com/WW/view/en/73443294)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "http://support.automation.siemens.com/WW/view/en/73443294"
},
{
"category": "mitigation",
"details": "Siemens security advisory is located here: (https://cert-portal.siemens.com/productcert/pdf/ssa-345843.pdf)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-345843.pdf"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2013-3958",
"cwe": {
"id": "CWE-798",
"name": "Use of Hard-coded Credentials"
},
"notes": [
{
"category": "summary",
"text": "The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Siemens has produced a software update that resolves these vulnerabilities. The update can be applied to all versions of WinCC Web Navigator starting with Version 7.2. Siemens recommends that asset owners and operators contact Siemens customer support to acquire the update.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Siemens update information is located here: (http://support.automation.siemens.com/WW/view/en/73443294)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "http://support.automation.siemens.com/WW/view/en/73443294"
},
{
"category": "mitigation",
"details": "Siemens security advisory is located here: (https://cert-portal.siemens.com/productcert/pdf/ssa-345843.pdf)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-345843.pdf"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2013-3959",
"cwe": {
"id": "CWE-425",
"name": "Direct Request (\u0027Forced Browsing\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Siemens has produced a software update that resolves these vulnerabilities. The update can be applied to all versions of WinCC Web Navigator starting with Version 7.2. Siemens recommends that asset owners and operators contact Siemens customer support to acquire the update.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Siemens update information is located here: (http://support.automation.siemens.com/WW/view/en/73443294)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "http://support.automation.siemens.com/WW/view/en/73443294"
},
{
"category": "mitigation",
"details": "Siemens security advisory is located here: (https://cert-portal.siemens.com/productcert/pdf/ssa-345843.pdf)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-345843.pdf"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 4.0,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
VAR-201306-0316
Vulnerability from variot - Updated: 2025-04-11 22:59The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. Siemens SIMATIC PCS is a process control system. Siemens SIMATIC WinCC And PCS 7 are prone to a username-enumeration weakness because of a design error in the application when verifying user-supplied input. Attackers may exploit this weakness to discern valid usernames. This may aid brute-force password cracking or other attacks. There is a vulnerability in the Web Navigator in Siemens WinCC 7.2 Update 1 and earlier versions used in SIMATIC PCS7 8.0 SP1 and earlier versions and other products
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201306-0316",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.1"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic pcs7",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "wincc",
"version": "7.0"
},
{
"model": "simatic pcs 7",
"scope": "lte",
"trust": 0.8,
"vendor": "siemens",
"version": "8.0 sp1"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "7.2 update 1"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.x"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "78.x"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "7.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "wincc",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:siemens:simatic_pcs_7",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Alexander Tlyapov from Positive Technologies",
"sources": [
{
"db": "BID",
"id": "60559"
}
],
"trust": 0.3
},
"cve": "CVE-2013-3959",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2013-3959",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CNVD-2013-07608",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "VHN-63961",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2013-3959",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2013-3959",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2013-07608",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201306-249",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-63961",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "VULHUB",
"id": "VHN-63961"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. Siemens SIMATIC PCS is a process control system. Siemens SIMATIC WinCC And PCS 7 are prone to a username-enumeration weakness because of a design error in the application when verifying user-supplied input. \nAttackers may exploit this weakness to discern valid usernames. This may aid brute-force password cracking or other attacks. There is a vulnerability in the Web Navigator in Siemens WinCC 7.2 Update 1 and earlier versions used in SIMATIC PCS7 8.0 SP1 and earlier versions and other products",
"sources": [
{
"db": "NVD",
"id": "CVE-2013-3959"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "BID",
"id": "60559"
},
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-63961"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2013-3959",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-345843",
"trust": 2.0
},
{
"db": "SECUNIA",
"id": "53805",
"trust": 1.2
},
{
"db": "ICS CERT",
"id": "ICSA-13-169-02",
"trust": 1.1
},
{
"db": "BID",
"id": "60559",
"trust": 1.0
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2013-07608",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984",
"trust": 0.8
},
{
"db": "IVD",
"id": "E694E1EA-2352-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-63961",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "VULHUB",
"id": "VHN-63961"
},
{
"db": "BID",
"id": "60559"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
}
]
},
"id": "VAR-201306-0316",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "VULHUB",
"id": "VHN-63961"
}
],
"trust": 1.5048571666666666
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
}
]
},
"last_update_date": "2025-04-11T22:59:07.231000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-345843: Vulnerabilites in WinCC 7.2",
"trust": 0.8,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
},
{
"title": "Siemens SIMATIC WinCC/PCS 7 User Name Enumeration Patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/34668"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-63961"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
},
{
"trust": 1.1,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-13-169-02"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-3959"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-3959"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/53805/"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/53805"
},
{
"trust": 0.3,
"url": "http://www.siemens.com/"
},
{
"trust": 0.3,
"url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/scada/simatic-wincc/pages/default.aspx"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "VULHUB",
"id": "VHN-63961"
},
{
"db": "BID",
"id": "60559"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "VULHUB",
"id": "VHN-63961"
},
{
"db": "BID",
"id": "60559"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2013-06-19T00:00:00",
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"date": "2013-06-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"date": "2013-06-14T00:00:00",
"db": "VULHUB",
"id": "VHN-63961"
},
{
"date": "2013-06-14T00:00:00",
"db": "BID",
"id": "60559"
},
{
"date": "2013-06-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"date": "2013-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201306-249"
},
{
"date": "2013-06-14T19:55:01.270000",
"db": "NVD",
"id": "CVE-2013-3959"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2013-06-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"date": "2013-06-17T00:00:00",
"db": "VULHUB",
"id": "VHN-63961"
},
{
"date": "2015-03-19T09:11:00",
"db": "BID",
"id": "60559"
},
{
"date": "2013-06-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"date": "2013-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201306-249"
},
{
"date": "2025-04-11T00:51:21.963000",
"db": "NVD",
"id": "CVE-2013-3959"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC/PCS 7 User Name Enumeration Vulnerability",
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.