    CVE-2025-64778 (GCVE-0-2025-64778)

    Vulnerability from nvd – Published: 2025-12-02 21:09 – Updated: 2025-12-02 21:38
    VLAI
    Title
    Mirion Medical EC2 Software NMIS BioDose Use of Hard-coded Credentials
    Summary
    NMIS/BioDose software V22.02 and previous versions contain executable binaries with plain text hard-coded passwords. These hard-coded passwords could allow unauthorized access to both the application and database.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    Impacted products
    Vendor Product Version
    Mirion Medical EC2 Software NMIS BioDose Affected: 0 , < 23.0 (custom)
    Unaffected: 23.0
    Create a notification for this product.
    Date Public
    2025-12-02 17:00
    Credits
    Joe Dillon reported these vulnerabilities to Mirion Medical.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-64778",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T21:38:39.518064Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T21:38:49.345Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EC2 Software NMIS BioDose",
              "vendor": "Mirion Medical",
              "versions": [
                {
                  "lessThan": "23.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "23.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Mirion Medical."
            }
          ],
          "datePublic": "2025-12-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eNMIS/BioDose software V22.02 and previous versions contain executable binaries with plain text hard-coded passwords. These hard-coded passwords could allow unauthorized access to both the application and database.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "NMIS/BioDose software V22.02 and previous versions contain executable binaries with plain text hard-coded passwords. These hard-coded passwords could allow unauthorized access to both the application and database."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T21:09:38.450Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-336-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMirion Medical support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;directly.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Mirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact Mirion Medical support\u00a0directly."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-336-01",
            "discovery": "EXTERNAL"
          },
          "title": "Mirion Medical EC2 Software NMIS BioDose Use of Hard-coded Credentials",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-64778",
        "datePublished": "2025-12-02T21:09:38.450Z",
        "dateReserved": "2025-11-11T20:56:52.864Z",
        "dateUpdated": "2025-12-02T21:38:49.345Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-64642 (GCVE-0-2025-64642)

    Vulnerability from nvd – Published: 2025-12-02 21:03 – Updated: 2025-12-02 21:40
    VLAI
    Title
    Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource
    Summary
    NMIS/BioDose V22.02 and previous versions' installation directory paths by default have insecure file permissions, which in certain deployment scenarios can enable users on client workstations to modify the program executables and libraries.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    Impacted products
    Vendor Product Version
    Mirion Medical EC2 Software NMIS BioDose Affected: 0 , < 23.0 (custom)
    Create a notification for this product.
    Date Public
    2025-12-02 17:00
    Credits
    Joe Dillon reported these vulnerabilities to Mirion Medical.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-64642",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T21:40:33.476038Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T21:40:46.180Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EC2 Software NMIS BioDose",
              "vendor": "Mirion Medical",
              "versions": [
                {
                  "lessThan": "23.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Mirion Medical."
            }
          ],
          "datePublic": "2025-12-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eNMIS/BioDose V22.02 and previous versions\u0027 installation directory paths by default have insecure file permissions, which in certain deployment scenarios can enable users on client workstations to modify the program executables and libraries.\u003c/span\u003e"
                }
              ],
              "value": "NMIS/BioDose V22.02 and previous versions\u0027 installation directory paths by default have insecure file permissions, which in certain deployment scenarios can enable users on client workstations to modify the program executables and libraries."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T21:03:43.349Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-336-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMirion Medical support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;directly.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Mirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact Mirion Medical support\u00a0directly."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-336-01",
            "discovery": "EXTERNAL"
          },
          "title": "Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-64642",
        "datePublished": "2025-12-02T21:03:43.349Z",
        "dateReserved": "2025-11-11T20:56:52.827Z",
        "dateUpdated": "2025-12-02T21:40:46.180Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-64298 (GCVE-0-2025-64298)

    Vulnerability from nvd – Published: 2025-12-02 21:05 – Updated: 2025-12-09 17:03
    VLAI
    Title
    Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource
    Summary
    NMIS/BioDose V22.02 and previous version installations where the embedded Microsoft SQLServer Express is used are exposed in the Windows share accessed by clients in networked installs. By default, this directory has insecure directory paths that allow access to the SQL Server database and configuration files, which can contain sensitive data.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    Impacted products
    Vendor Product Version
    Mirion Medical EC2 Software NMIS BioDose Affected: 0 , < 23.0 (custom)
    Unaffected: 23.0
    Create a notification for this product.
    Date Public
    2025-12-02 17:00
    Credits
    Joe Dillon reported these vulnerabilities to Mirion Medical.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-64298",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-09T17:03:03.295083Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-09T17:03:09.449Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EC2 Software NMIS BioDose",
              "vendor": "Mirion Medical",
              "versions": [
                {
                  "lessThan": "23.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "23.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Mirion Medical."
            }
          ],
          "datePublic": "2025-12-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eNMIS/BioDose V22.02 and previous version installations where the embedded Microsoft SQLServer Express is used are exposed in the Windows share accessed by clients in networked installs. By default, this directory has insecure directory paths that allow access to the SQL Server database and configuration files, which can contain sensitive data.\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "NMIS/BioDose V22.02 and previous version installations where the embedded Microsoft SQLServer Express is used are exposed in the Windows share accessed by clients in networked installs. By default, this directory has insecure directory paths that allow access to the SQL Server database and configuration files, which can contain sensitive data."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T21:05:38.266Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-336-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMirion Medical support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;directly.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Mirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact Mirion Medical support\u00a0directly."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-336-01",
            "discovery": "EXTERNAL"
          },
          "title": "Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-64298",
        "datePublished": "2025-12-02T21:05:38.266Z",
        "dateReserved": "2025-11-11T20:56:52.837Z",
        "dateUpdated": "2025-12-09T17:03:09.449Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-62575 (GCVE-0-2025-62575)

    Vulnerability from nvd – Published: 2025-12-02 21:11 – Updated: 2025-12-02 21:37
    VLAI
    Title
    Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource
    Summary
    NMIS/BioDose V22.02 and previous versions rely on a Microsoft SQL Server database. The SQL user account 'nmdbuser' and other created accounts by default have the sysadmin role. This can lead to remote code execution through the use of certain built-in stored procedures.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    Impacted products
    Vendor Product Version
    Mirion Medical EC2 Software NMIS BioDose Affected: 0 , < 23.0 (custom)
    Unaffected: 23.0
    Create a notification for this product.
    Date Public
    2025-12-02 17:00
    Credits
    Joe Dillon reported these vulnerabilities to Mirion Medical.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-62575",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T21:37:17.666393Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T21:37:46.825Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EC2 Software NMIS BioDose",
              "vendor": "Mirion Medical",
              "versions": [
                {
                  "lessThan": "23.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "23.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Mirion Medical."
            }
          ],
          "datePublic": "2025-12-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eNMIS/BioDose V22.02 and previous versions rely on a Microsoft SQL Server database. The SQL user account \u0027nmdbuser\u0027 and other created accounts by default have the sysadmin role. This can lead to remote code execution through the use of certain built-in stored procedures.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "NMIS/BioDose V22.02 and previous versions rely on a Microsoft SQL Server database. The SQL user account \u0027nmdbuser\u0027 and other created accounts by default have the sysadmin role. This can lead to remote code execution through the use of certain built-in stored procedures."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T21:11:20.484Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-336-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMirion Medical support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;directly.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Mirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact Mirion Medical support\u00a0directly."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-336-01",
            "discovery": "EXTERNAL"
          },
          "title": "Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-62575",
        "datePublished": "2025-12-02T21:11:20.484Z",
        "dateReserved": "2025-11-11T20:56:52.854Z",
        "dateUpdated": "2025-12-02T21:37:46.825Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-61940 (GCVE-0-2025-61940)

    Vulnerability from nvd – Published: 2025-12-02 21:07 – Updated: 2025-12-09 17:03
    VLAI
    Title
    Mirion Medical EC2 Software NMIS BioDose Use of Client-Side Authentication
    Summary
    NMIS/BioDose V22.02 and previous versions rely on a common SQL Server user account to access data in the database. User access in the client application is restricted by a password authentication check in the client software but the underlying database connection always has access. The latest version of NMIS/BioDose introduces an option to use Windows user authentication with the database, which would restrict this database connection.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Mirion Medical EC2 Software NMIS BioDose Affected: 0 , < 23.0 (custom)
    Unaffected: 23.0
    Create a notification for this product.
    Date Public
    2025-12-02 17:00
    Credits
    Joe Dillon reported these vulnerabilities to Mirion Medical.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-61940",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-09T17:03:20.801749Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-09T17:03:27.576Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EC2 Software NMIS BioDose",
              "vendor": "Mirion Medical",
              "versions": [
                {
                  "lessThan": "23.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "23.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Mirion Medical."
            }
          ],
          "datePublic": "2025-12-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eNMIS/BioDose V22.02 and previous versions rely on a common SQL Server user account to access data in the database. User access in the client application is restricted by a password authentication check in the client software but the underlying database connection always has access. The latest version of NMIS/BioDose introduces an option to use Windows user authentication with the database, which would restrict this database connection.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "NMIS/BioDose V22.02 and previous versions rely on a common SQL Server user account to access data in the database. User access in the client application is restricted by a password authentication check in the client software but the underlying database connection always has access. The latest version of NMIS/BioDose introduces an option to use Windows user authentication with the database, which would restrict this database connection."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-603",
                  "description": "CWE-603",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T21:07:47.995Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-336-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMirion Medical support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;directly.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Mirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact Mirion Medical support\u00a0directly."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-336-01",
            "discovery": "EXTERNAL"
          },
          "title": "Mirion Medical EC2 Software NMIS BioDose Use of Client-Side Authentication",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-61940",
        "datePublished": "2025-12-02T21:07:47.995Z",
        "dateReserved": "2025-11-11T20:56:52.843Z",
        "dateUpdated": "2025-12-09T17:03:27.576Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-62575 (GCVE-0-2025-62575)

    Vulnerability from cvelistv5 – Published: 2025-12-02 21:11 – Updated: 2025-12-02 21:37
    VLAI
    Title
    Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource
    Summary
    NMIS/BioDose V22.02 and previous versions rely on a Microsoft SQL Server database. The SQL user account 'nmdbuser' and other created accounts by default have the sysadmin role. This can lead to remote code execution through the use of certain built-in stored procedures.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    Impacted products
    Vendor Product Version
    Mirion Medical EC2 Software NMIS BioDose Affected: 0 , < 23.0 (custom)
    Unaffected: 23.0
    Create a notification for this product.
    Date Public
    2025-12-02 17:00
    Credits
    Joe Dillon reported these vulnerabilities to Mirion Medical.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-62575",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T21:37:17.666393Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T21:37:46.825Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EC2 Software NMIS BioDose",
              "vendor": "Mirion Medical",
              "versions": [
                {
                  "lessThan": "23.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "23.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Mirion Medical."
            }
          ],
          "datePublic": "2025-12-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eNMIS/BioDose V22.02 and previous versions rely on a Microsoft SQL Server database. The SQL user account \u0027nmdbuser\u0027 and other created accounts by default have the sysadmin role. This can lead to remote code execution through the use of certain built-in stored procedures.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "NMIS/BioDose V22.02 and previous versions rely on a Microsoft SQL Server database. The SQL user account \u0027nmdbuser\u0027 and other created accounts by default have the sysadmin role. This can lead to remote code execution through the use of certain built-in stored procedures."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T21:11:20.484Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-336-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMirion Medical support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;directly.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Mirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact Mirion Medical support\u00a0directly."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-336-01",
            "discovery": "EXTERNAL"
          },
          "title": "Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-62575",
        "datePublished": "2025-12-02T21:11:20.484Z",
        "dateReserved": "2025-11-11T20:56:52.854Z",
        "dateUpdated": "2025-12-02T21:37:46.825Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-64778 (GCVE-0-2025-64778)

    Vulnerability from cvelistv5 – Published: 2025-12-02 21:09 – Updated: 2025-12-02 21:38
    VLAI
    Title
    Mirion Medical EC2 Software NMIS BioDose Use of Hard-coded Credentials
    Summary
    NMIS/BioDose software V22.02 and previous versions contain executable binaries with plain text hard-coded passwords. These hard-coded passwords could allow unauthorized access to both the application and database.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    Impacted products
    Vendor Product Version
    Mirion Medical EC2 Software NMIS BioDose Affected: 0 , < 23.0 (custom)
    Unaffected: 23.0
    Create a notification for this product.
    Date Public
    2025-12-02 17:00
    Credits
    Joe Dillon reported these vulnerabilities to Mirion Medical.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-64778",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T21:38:39.518064Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T21:38:49.345Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EC2 Software NMIS BioDose",
              "vendor": "Mirion Medical",
              "versions": [
                {
                  "lessThan": "23.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "23.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Mirion Medical."
            }
          ],
          "datePublic": "2025-12-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eNMIS/BioDose software V22.02 and previous versions contain executable binaries with plain text hard-coded passwords. These hard-coded passwords could allow unauthorized access to both the application and database.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "NMIS/BioDose software V22.02 and previous versions contain executable binaries with plain text hard-coded passwords. These hard-coded passwords could allow unauthorized access to both the application and database."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T21:09:38.450Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-336-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMirion Medical support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;directly.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Mirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact Mirion Medical support\u00a0directly."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-336-01",
            "discovery": "EXTERNAL"
          },
          "title": "Mirion Medical EC2 Software NMIS BioDose Use of Hard-coded Credentials",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-64778",
        "datePublished": "2025-12-02T21:09:38.450Z",
        "dateReserved": "2025-11-11T20:56:52.864Z",
        "dateUpdated": "2025-12-02T21:38:49.345Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-61940 (GCVE-0-2025-61940)

    Vulnerability from cvelistv5 – Published: 2025-12-02 21:07 – Updated: 2025-12-09 17:03
    VLAI
    Title
    Mirion Medical EC2 Software NMIS BioDose Use of Client-Side Authentication
    Summary
    NMIS/BioDose V22.02 and previous versions rely on a common SQL Server user account to access data in the database. User access in the client application is restricted by a password authentication check in the client software but the underlying database connection always has access. The latest version of NMIS/BioDose introduces an option to use Windows user authentication with the database, which would restrict this database connection.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Mirion Medical EC2 Software NMIS BioDose Affected: 0 , < 23.0 (custom)
    Unaffected: 23.0
    Create a notification for this product.
    Date Public
    2025-12-02 17:00
    Credits
    Joe Dillon reported these vulnerabilities to Mirion Medical.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-61940",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-09T17:03:20.801749Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-09T17:03:27.576Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EC2 Software NMIS BioDose",
              "vendor": "Mirion Medical",
              "versions": [
                {
                  "lessThan": "23.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "23.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Mirion Medical."
            }
          ],
          "datePublic": "2025-12-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eNMIS/BioDose V22.02 and previous versions rely on a common SQL Server user account to access data in the database. User access in the client application is restricted by a password authentication check in the client software but the underlying database connection always has access. The latest version of NMIS/BioDose introduces an option to use Windows user authentication with the database, which would restrict this database connection.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "NMIS/BioDose V22.02 and previous versions rely on a common SQL Server user account to access data in the database. User access in the client application is restricted by a password authentication check in the client software but the underlying database connection always has access. The latest version of NMIS/BioDose introduces an option to use Windows user authentication with the database, which would restrict this database connection."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-603",
                  "description": "CWE-603",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T21:07:47.995Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-336-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMirion Medical support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;directly.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Mirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact Mirion Medical support\u00a0directly."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-336-01",
            "discovery": "EXTERNAL"
          },
          "title": "Mirion Medical EC2 Software NMIS BioDose Use of Client-Side Authentication",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-61940",
        "datePublished": "2025-12-02T21:07:47.995Z",
        "dateReserved": "2025-11-11T20:56:52.843Z",
        "dateUpdated": "2025-12-09T17:03:27.576Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-64298 (GCVE-0-2025-64298)

    Vulnerability from cvelistv5 – Published: 2025-12-02 21:05 – Updated: 2025-12-09 17:03
    VLAI
    Title
    Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource
    Summary
    NMIS/BioDose V22.02 and previous version installations where the embedded Microsoft SQLServer Express is used are exposed in the Windows share accessed by clients in networked installs. By default, this directory has insecure directory paths that allow access to the SQL Server database and configuration files, which can contain sensitive data.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    Impacted products
    Vendor Product Version
    Mirion Medical EC2 Software NMIS BioDose Affected: 0 , < 23.0 (custom)
    Unaffected: 23.0
    Create a notification for this product.
    Date Public
    2025-12-02 17:00
    Credits
    Joe Dillon reported these vulnerabilities to Mirion Medical.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-64298",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-09T17:03:03.295083Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-09T17:03:09.449Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EC2 Software NMIS BioDose",
              "vendor": "Mirion Medical",
              "versions": [
                {
                  "lessThan": "23.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "23.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Mirion Medical."
            }
          ],
          "datePublic": "2025-12-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eNMIS/BioDose V22.02 and previous version installations where the embedded Microsoft SQLServer Express is used are exposed in the Windows share accessed by clients in networked installs. By default, this directory has insecure directory paths that allow access to the SQL Server database and configuration files, which can contain sensitive data.\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "NMIS/BioDose V22.02 and previous version installations where the embedded Microsoft SQLServer Express is used are exposed in the Windows share accessed by clients in networked installs. By default, this directory has insecure directory paths that allow access to the SQL Server database and configuration files, which can contain sensitive data."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T21:05:38.266Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-336-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMirion Medical support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;directly.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Mirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact Mirion Medical support\u00a0directly."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-336-01",
            "discovery": "EXTERNAL"
          },
          "title": "Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-64298",
        "datePublished": "2025-12-02T21:05:38.266Z",
        "dateReserved": "2025-11-11T20:56:52.837Z",
        "dateUpdated": "2025-12-09T17:03:09.449Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-64642 (GCVE-0-2025-64642)

    Vulnerability from cvelistv5 – Published: 2025-12-02 21:03 – Updated: 2025-12-02 21:40
    VLAI
    Title
    Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource
    Summary
    NMIS/BioDose V22.02 and previous versions' installation directory paths by default have insecure file permissions, which in certain deployment scenarios can enable users on client workstations to modify the program executables and libraries.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    Impacted products
    Vendor Product Version
    Mirion Medical EC2 Software NMIS BioDose Affected: 0 , < 23.0 (custom)
    Create a notification for this product.
    Date Public
    2025-12-02 17:00
    Credits
    Joe Dillon reported these vulnerabilities to Mirion Medical.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-64642",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T21:40:33.476038Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T21:40:46.180Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EC2 Software NMIS BioDose",
              "vendor": "Mirion Medical",
              "versions": [
                {
                  "lessThan": "23.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joe Dillon reported these vulnerabilities to Mirion Medical."
            }
          ],
          "datePublic": "2025-12-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eNMIS/BioDose V22.02 and previous versions\u0027 installation directory paths by default have insecure file permissions, which in certain deployment scenarios can enable users on client workstations to modify the program executables and libraries.\u003c/span\u003e"
                }
              ],
              "value": "NMIS/BioDose V22.02 and previous versions\u0027 installation directory paths by default have insecure file permissions, which in certain deployment scenarios can enable users on client workstations to modify the program executables and libraries."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T21:03:43.349Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-336-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eMirion Medical support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;directly.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Mirion Medical recommends users update to V23.0 or later. Users with an active support contract should update to the latest version through the software or users can contact Mirion Medical support\u00a0directly."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-336-01",
            "discovery": "EXTERNAL"
          },
          "title": "Mirion Medical EC2 Software NMIS BioDose Incorrect Permission Assignment for Critical Resource",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-64642",
        "datePublished": "2025-12-02T21:03:43.349Z",
        "dateReserved": "2025-11-11T20:56:52.827Z",
        "dateUpdated": "2025-12-02T21:40:46.180Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    VAR-201709-1107

    Vulnerability from variot - Updated: 2025-04-20 23:19

    A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). An unchangeable, factory-set key is included in the 900 MHz transmitter firmware. plural Mirion Technologies The product contains a vulnerability related to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Mirion Technologies provides a source of solutions for nuclear, military, radiation detection and monitoring. Mirion Technologies Telemetry Enabled Devices is a denial of service vulnerability that could allow an attacker to transmit fraudulent data or perform denial of service. Successfully exploiting these issues may allow an attacker to bypass certain security restrictions and perform unauthorized actions. This may aid in further attacks. RSD31-AM Package), DRM-1/2 and variants (incl. are products of Mirion Technologies in the United States. Mirion Technologies DMC 3000 Transmitter Module is a DMC 3000 series control card

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201709-1107",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dmc 3000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "wrm2 mesh repeater",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telepole ii",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "rds-31 itx",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "ipam transmitter f\\/dmc 2000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "rsd31-am",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "drm-1\\/2",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "dmc 3000 transmitter module",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "drm-1/2",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "ipam transmitter f/dmc 2000",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "mesh repeater",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "rds-31 itx",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "rsd31-am",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telepole ii",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices dmc transmitter module",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "mirion",
            "version": "3000"
          },
          {
            "model": "telemetry enabled devices ipam transmitter f/dmc",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "mirion",
            "version": "2000"
          },
          {
            "model": "telemetry enabled devices rds-31 itx and variants",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices drm-1/2 and variants",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices drm and rds based boundary monitors",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices telepole ii",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices external transmitters",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices mesh repeater",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telepole ii",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "rds-31 itx",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "mesh repeater",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "ipam transmitter f/dmc",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "20000"
          },
          {
            "model": "external transmitters",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "drm-1/2",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "drm and rds based boundary monitors",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "dmc transmitter module",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "30000"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dmc 3000",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ipam transmitter f dmc 2000",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "telepole ii",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "rds 31 itx",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "rsd31 am",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "wrm2 mesh repeater",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "drm 1 2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "bb97c299-9654-48d6-b71d-ff9ddcbcad7f"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          },
          {
            "db": "BID",
            "id": "100001"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008474"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-588"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9649"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:dmc_3000_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:drm-1%2F2_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:ipam_transmitter_f%2Fdmc_2000_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:wrm2_mesh_repeater_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:rds-31_itx_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:rsd31-am_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:telepole_ii_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008474"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Ruben Santamarta of IOActive",
        "sources": [
          {
            "db": "BID",
            "id": "100001"
          }
        ],
        "trust": 0.3
      },
      "cve": "CVE-2017-9649",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.4,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.5,
                "id": "CVE-2017-9649",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:A/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "HIGH",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.2,
                "id": "CNVD-2017-22838",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:A/AC:H/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "HIGH",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.2,
                "id": "bb97c299-9654-48d6-b71d-ff9ddcbcad7f",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:A/AC:H/Au:N/C:P/I:P/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.4,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.5,
                "id": "VHN-117852",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:A/AC:M/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "LOW",
                "baseScore": 5.0,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.6,
                "id": "CVE-2017-9649",
                "impactScore": 3.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-9649",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-9649",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-22838",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201706-588",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "IVD",
                "id": "bb97c299-9654-48d6-b71d-ff9ddcbcad7f",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-117852",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "bb97c299-9654-48d6-b71d-ff9ddcbcad7f"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117852"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008474"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-588"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9649"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). An unchangeable, factory-set key is included in the 900 MHz transmitter firmware. plural Mirion Technologies The product contains a vulnerability related to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Mirion Technologies provides a source of solutions for nuclear, military, radiation detection and monitoring. Mirion Technologies Telemetry Enabled Devices is a denial of service vulnerability that could allow an attacker to transmit fraudulent data or perform denial of service. \nSuccessfully exploiting these issues may allow an attacker to bypass certain security restrictions and perform unauthorized actions. This may aid in further attacks. RSD31-AM Package),\nDRM-1/2 and variants (incl. are products of Mirion Technologies in the United States. Mirion Technologies DMC 3000 Transmitter Module is a DMC 3000 series control card",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9649"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008474"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          },
          {
            "db": "BID",
            "id": "100001"
          },
          {
            "db": "IVD",
            "id": "bb97c299-9654-48d6-b71d-ff9ddcbcad7f"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117852"
          }
        ],
        "trust": 2.7
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-9649",
            "trust": 3.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-17-208-02",
            "trust": 3.4
          },
          {
            "db": "BID",
            "id": "100001",
            "trust": 2.0
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-588",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22838",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008474",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "BB97C299-9654-48D6-B71D-FF9DDCBCAD7F",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-117852",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "bb97c299-9654-48d6-b71d-ff9ddcbcad7f"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117852"
          },
          {
            "db": "BID",
            "id": "100001"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008474"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-588"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9649"
          }
        ]
      },
      "id": "VAR-201709-1107",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "bb97c299-9654-48d6-b71d-ff9ddcbcad7f"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117852"
          }
        ],
        "trust": 1.9
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "bb97c299-9654-48d6-b71d-ff9ddcbcad7f"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:19:50.303000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.mirion.com/"
          },
          {
            "title": "Mirion Technologies Telemetry Enabled Devices Patch for Denial of Service Vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/100845"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008474"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.9
          },
          {
            "problemtype": "CWE-321",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-117852"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008474"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9649"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.4,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-208-02"
          },
          {
            "trust": 1.7,
            "url": "http://www.securityfocus.com/bid/100001"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9649"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9649"
          },
          {
            "trust": 0.3,
            "url": "https://www.mirion.com/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117852"
          },
          {
            "db": "BID",
            "id": "100001"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008474"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-588"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9649"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "bb97c299-9654-48d6-b71d-ff9ddcbcad7f"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117852"
          },
          {
            "db": "BID",
            "id": "100001"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008474"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-588"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9649"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-08-25T00:00:00",
            "db": "IVD",
            "id": "bb97c299-9654-48d6-b71d-ff9ddcbcad7f"
          },
          {
            "date": "2017-08-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          },
          {
            "date": "2017-09-20T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117852"
          },
          {
            "date": "2017-07-27T00:00:00",
            "db": "BID",
            "id": "100001"
          },
          {
            "date": "2017-10-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-008474"
          },
          {
            "date": "2017-06-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-588"
          },
          {
            "date": "2017-09-20T16:29:01.097000",
            "db": "NVD",
            "id": "CVE-2017-9649"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-08-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          },
          {
            "date": "2019-10-09T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117852"
          },
          {
            "date": "2017-07-27T00:00:00",
            "db": "BID",
            "id": "100001"
          },
          {
            "date": "2017-10-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-008474"
          },
          {
            "date": "2019-10-17T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-588"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-9649"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-588"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Mirion Technologies Telemetry Enabled Devices Denial of service vulnerability",
        "sources": [
          {
            "db": "IVD",
            "id": "bb97c299-9654-48d6-b71d-ff9ddcbcad7f"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22838"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-588"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201709-1106

    Vulnerability from variot - Updated: 2025-04-20 23:19

    An Inadequate Encryption Strength issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). Decryption of data is possible at the hardware level. plural Mirion Technologies The product contains a vulnerability related to cryptographic strength.Information may be obtained. Mirion Technologies provides a source of solutions for nuclear, military, radiation detection and monitoring. Mirion Technologies Telemetry Enabled Devices is a denial of service vulnerability that could be exploited by an attacker to transmit fraudulent data or perform denial of service. Successfully exploiting these issues may allow an attacker to bypass certain security restrictions and perform unauthorized actions. This may aid in further attacks. RSD31-AM Package), DRM-1/2 and variants (incl. Security vulnerabilities exist in several Mirion Technologies products

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201709-1106",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rds-31",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "wrm2",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "drm-2",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "drm-1\\/2",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "rds-31 itx",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "dmc 3000 transmitter",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "ipam transmitter f\\/dmc 2000",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telepole 2",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "dmc 3000 transmitter module",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "drm-1/2",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "ipam transmitter f/dmc 2000",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "mesh repeater",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "rds-31 itx",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "rsd31-am",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telepole ii",
            "scope": null,
            "trust": 0.8,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices dmc transmitter module",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "mirion",
            "version": "3000"
          },
          {
            "model": "telemetry enabled devices ipam transmitter f/dmc",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "mirion",
            "version": "2000"
          },
          {
            "model": "telemetry enabled devices rds-31 itx and variants",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices drm-1/2 and variants",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices drm and rds based boundary monitors",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices telepole ii",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices external transmitters",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telemetry enabled devices mesh repeater",
            "scope": null,
            "trust": 0.6,
            "vendor": "mirion",
            "version": null
          },
          {
            "model": "telepole ii",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "rds-31 itx",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "mesh repeater",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "ipam transmitter f/dmc",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "20000"
          },
          {
            "model": "external transmitters",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "drm-1/2",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "drm and rds based boundary monitors",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "0"
          },
          {
            "model": "dmc transmitter module",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "mirion",
            "version": "30000"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dmc 3000 transmitter",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ipam transmitter f dmc 2000",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "rds 31 itx",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "drm 1 2",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "drm 2",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "rds 31",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "telepole 2",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "wrm2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "d3a1f9ff-b730-4b2e-ac28-ccbfc599ff91"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22839"
          },
          {
            "db": "BID",
            "id": "100001"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-592"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9645"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:dmc_3000_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:drm-1%2F2_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:ipam_transmitter_f%2Fdmc_2000_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:wrm2_mesh_repeater_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:rds-31_itx_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:rsd31-am_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mirion_technologies:telepole_ii_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Ruben Santamarta of IOActive",
        "sources": [
          {
            "db": "BID",
            "id": "100001"
          }
        ],
        "trust": 0.3
      },
      "cve": "CVE-2017-9645",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2017-9645",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 1.8,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "HIGH",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.2,
                "id": "CNVD-2017-22839",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:A/AC:H/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "HIGH",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.2,
                "id": "d3a1f9ff-b730-4b2e-ac28-ccbfc599ff91",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:A/AC:H/Au:N/C:P/I:P/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "VHN-117848",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 0.1,
                "vectorString": "AV:A/AC:L/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2017-9645",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2017-9645",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2017-9645",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-22839",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201706-592",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "IVD",
                "id": "d3a1f9ff-b730-4b2e-ac28-ccbfc599ff91",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-117848",
                "trust": 0.1,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "d3a1f9ff-b730-4b2e-ac28-ccbfc599ff91"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22839"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117848"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-592"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9645"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An Inadequate Encryption Strength issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). Decryption of data is possible at the hardware level. plural Mirion Technologies The product contains a vulnerability related to cryptographic strength.Information may be obtained. Mirion Technologies provides a source of solutions for nuclear, military, radiation detection and monitoring. Mirion Technologies Telemetry Enabled Devices is a denial of service vulnerability that could be exploited by an attacker to transmit fraudulent data or perform denial of service. \nSuccessfully exploiting these issues may allow an attacker to bypass certain security restrictions and perform unauthorized actions. This may aid in further attacks. RSD31-AM Package),\nDRM-1/2 and variants (incl. Security vulnerabilities exist in several Mirion Technologies products",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9645"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22839"
          },
          {
            "db": "BID",
            "id": "100001"
          },
          {
            "db": "IVD",
            "id": "d3a1f9ff-b730-4b2e-ac28-ccbfc599ff91"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117848"
          }
        ],
        "trust": 2.7
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-9645",
            "trust": 3.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-17-208-02",
            "trust": 3.4
          },
          {
            "db": "BID",
            "id": "100001",
            "trust": 2.0
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-592",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22839",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008473",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "D3A1F9FF-B730-4B2E-AC28-CCBFC599FF91",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-117848",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "d3a1f9ff-b730-4b2e-ac28-ccbfc599ff91"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22839"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117848"
          },
          {
            "db": "BID",
            "id": "100001"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-592"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9645"
          }
        ]
      },
      "id": "VAR-201709-1106",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "d3a1f9ff-b730-4b2e-ac28-ccbfc599ff91"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22839"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117848"
          }
        ],
        "trust": 1.9
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "d3a1f9ff-b730-4b2e-ac28-ccbfc599ff91"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22839"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:19:50.263000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.mirion.com/"
          },
          {
            "title": "Patch for Mirion Technologies Telemetry Enabled Devices Denial of Service Vulnerability (CNVD-2017-22839)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/100842"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-22839"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-326",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-117848"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9645"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.4,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-208-02"
          },
          {
            "trust": 1.7,
            "url": "http://www.securityfocus.com/bid/100001"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9645"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9645"
          },
          {
            "trust": 0.3,
            "url": "https://www.mirion.com/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-22839"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117848"
          },
          {
            "db": "BID",
            "id": "100001"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-592"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9645"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "d3a1f9ff-b730-4b2e-ac28-ccbfc599ff91"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22839"
          },
          {
            "db": "VULHUB",
            "id": "VHN-117848"
          },
          {
            "db": "BID",
            "id": "100001"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-592"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9645"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-08-25T00:00:00",
            "db": "IVD",
            "id": "d3a1f9ff-b730-4b2e-ac28-ccbfc599ff91"
          },
          {
            "date": "2017-08-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-22839"
          },
          {
            "date": "2017-09-20T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117848"
          },
          {
            "date": "2017-07-27T00:00:00",
            "db": "BID",
            "id": "100001"
          },
          {
            "date": "2017-10-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          },
          {
            "date": "2017-06-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-592"
          },
          {
            "date": "2017-09-20T16:29:01.003000",
            "db": "NVD",
            "id": "CVE-2017-9645"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-08-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-22839"
          },
          {
            "date": "2019-10-09T00:00:00",
            "db": "VULHUB",
            "id": "VHN-117848"
          },
          {
            "date": "2017-07-27T00:00:00",
            "db": "BID",
            "id": "100001"
          },
          {
            "date": "2017-10-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          },
          {
            "date": "2019-10-17T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-592"
          },
          {
            "date": "2025-04-20T01:37:25.860000",
            "db": "NVD",
            "id": "CVE-2017-9645"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-592"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Mirion Technologies Vulnerability related to cryptographic strength in products",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-008473"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "encryption problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-592"
          }
        ],
        "trust": 0.6
      }
    }