Search
Find a vulnerability
Search criteria
10 vulnerabilities by hitachi_energy
CVE-2024-41153 (GCVE-0-2024-41153)
Vulnerability from nvd – Published: 2024-10-29 12:30 – Updated: 2025-11-04 16:00
VLAI
EPSS
VEX
Summary
Command injection vulnerability in the Edge Computing UI for the
TRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the
web UI can execute commands on the device with root privileges,
far more extensive than what the write privilege intends.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-29 13:54 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Hitachi Energy
CNA
References
1 reference
| URL | Tags |
|---|---|
| https://publisher.hitachienergy.com/preview?Docum… | vendor-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | TRO600 |
Affected:
9.1.0.0 , ≤ 9.2.0.0
(custom)
|
|
| hitachi_energy | tro600 |
Affected:
9.1.0.0 , ≤ 9.2.0.0
(custom)
cpe:2.3:a:hitachi_energy:tro600:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_energy:tro600:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tro600",
"vendor": "hitachi_energy",
"versions": [
{
"lessThanOrEqual": "9.2.0.0",
"status": "affected",
"version": "9.1.0.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41153",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-29T13:54:05.290769Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-04T16:00:52.178Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TRO600",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "9.2.0.0",
"status": "affected",
"version": "9.1.0.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Command injection vulnerability in the Edge Computing UI for the\nTRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the\nweb UI can execute commands on the device with root privileges,\nfar more extensive than what the write privilege intends.\n\n\u003cbr\u003e"
}
],
"value": "Command injection vulnerability in the Edge Computing UI for the\nTRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the\nweb UI can execute commands on the device with root privileges,\nfar more extensive than what the write privilege intends."
}
],
"impacts": [
{
"capecId": "CAPEC-248",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-248 Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-24T08:38:07.234Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-41153",
"datePublished": "2024-10-29T12:30:31.402Z",
"dateReserved": "2024-07-16T16:02:30.295Z",
"dateUpdated": "2025-11-04T16:00:52.178Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-28024 (GCVE-0-2024-28024)
Vulnerability from nvd – Published: 2024-06-11 18:17 – Updated: 2024-10-29 14:42
VLAI
EPSS
VEX
Summary
A vulnerability exists in the FOXMAN-UN/UNEM in which sensitive information is
stored in cleartext within a resource that might be accessible to another control sphere.
Severity
4.1 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-11 20:22 UTC
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
Hitachi Energy
CNA
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | FOXMAN-UN |
Affected:
FOXMAN-UN R16B
Affected: FOXMAN-UN R15B Affected: FOXMAN-UN R16A Affected: FOXMAN-UN R15A |
|
| Hitachi Energy | UNEM |
Affected:
UNEM R16B
Affected: UNEM R15B Affected: UNEM R16A Affected: UNEM R15A |
|
| hitachi_energy | foxman-un |
Affected:
FOXMAN-UN R16B
Affected: FOXMAN-UN R15B Affected: FOXMAN-UN R16A Affected: FOXMAN-UN R15A cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:* |
|
| hitachi_energy | unem |
Affected:
UNEM R16B
Affected: UNEM R15B Affected: UNEM R16A Affected: UNEM R15A cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "foxman-un",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "FOXMAN-UN R16B"
},
{
"status": "affected",
"version": "FOXMAN-UN R15B"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unem",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "UNEM R16B"
},
{
"status": "affected",
"version": "UNEM R15B"
},
{
"status": "affected",
"version": "UNEM R16A"
},
{
"status": "affected",
"version": "UNEM R15A"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-28024",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-11T20:22:36.317764Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T20:39:33.569Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:48:47.698Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000201\u0026languageCode=en\u0026Preview=true"
},
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000194\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FOXMAN-UN",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "FOXMAN-UN R16B"
},
{
"status": "affected",
"version": "FOXMAN-UN R15B"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UNEM",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "UNEM R16B"
},
{
"status": "affected",
"version": "UNEM R15B"
},
{
"status": "affected",
"version": "UNEM R16A"
},
{
"status": "affected",
"version": "UNEM R15A"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the FOXMAN-UN/UNEM in which sensitive information is \nstored in cleartext within a resource that might be accessible to another control sphere."
}
],
"value": "A vulnerability exists in the FOXMAN-UN/UNEM in which sensitive information is \nstored in cleartext within a resource that might be accessible to another control sphere."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-29T14:42:42.760Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000201\u0026languageCode=en\u0026Preview=true"
},
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000194\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-28024",
"datePublished": "2024-06-11T18:17:54.877Z",
"dateReserved": "2024-02-29T13:42:00.746Z",
"dateUpdated": "2024-10-29T14:42:42.760Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2011 (GCVE-0-2024-2011)
Vulnerability from nvd – Published: 2024-06-11 13:24 – Updated: 2024-08-01 18:56
VLAI
EPSS
VEX
Summary
A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that
if exploited will generally lead to a denial of service but can be used
to execute arbitrary code, which is usually outside the scope of a
program's implicit security policy
Severity
8.6 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-18 19:34 UTC
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
Hitachi Energy
CNA
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | FOXMAN-UN |
Affected:
FOXMAN-UN R16B PC2
(custom)
Unaffected: FOXMAN-UN R16B PC3 , ≤ FOXMAN-UN R16B PC4 (custom) Affected: FOXMAN-UN R15B PC4 (custom) Unaffected: FOXMAN-UN R16B PC5 (custom) Affected: FOXMAN-UN R16A Affected: FOXMAN-UN R15A |
|
| Hitachi Energy | UNEM |
Affected:
UNEM R16B PC2
(custom)
Unaffected: UNEM R16B PC3 , ≤ UNEM R16B PC4 (custom) Affected: UNEM R15B PC4 (custom) Unaffected: UNEM R16B PC5 (custom) Affected: UNEM R16A Affected: UNEM R15A |
|
| hitachi_energy | foxman-un |
Affected:
FOXMAN-UN R16B PC2
Unaffected: FOXMAN-UN R16B PC3 , ≤ FOXMAN-UN R16B PC4 (custom) Affected: FOXMAN-UN R15B PC4 Unaffected: FOXMAN-UN R16B PC5 Affected: FOXMAN-UN R16A Affected: FOXMAN-UN R15A cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:* |
|
| hitachi_energy | unem |
Affected:
UNEM R16B PC2
Unaffected: UNEM R16B PC3 , ≤ UNEM R16B PC4 (custom) Affected: UNEM R15B PC4 Unaffected: UNEM R16B PC5 Affected: UNEM R16A Affected: UNEM R15A cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "foxman-un",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "FOXMAN-UN R16B PC2"
},
{
"lessThanOrEqual": "FOXMAN-UN R16B PC4",
"status": "unaffected",
"version": "FOXMAN-UN R16B PC3",
"versionType": "custom"
},
{
"status": "affected",
"version": "FOXMAN-UN R15B PC4"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R16B PC5"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unem",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "UNEM R16B PC2"
},
{
"lessThanOrEqual": "UNEM R16B PC4",
"status": "unaffected",
"version": "UNEM R16B PC3",
"versionType": "custom"
},
{
"status": "affected",
"version": "UNEM R15B PC4"
},
{
"status": "unaffected",
"version": "UNEM R16B PC5"
},
{
"status": "affected",
"version": "UNEM R16A"
},
{
"status": "affected",
"version": "UNEM R15A"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2011",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-18T19:34:01.919299Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-18T19:57:39.468Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:56:22.675Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000201\u0026languageCode=en\u0026Preview=true"
},
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000194\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FOXMAN-UN",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "FOXMAN-UN R16B PC2",
"versionType": "custom"
},
{
"lessThanOrEqual": "FOXMAN-UN R16B PC4",
"status": "unaffected",
"version": "FOXMAN-UN R16B PC3",
"versionType": "custom"
},
{
"status": "affected",
"version": "FOXMAN-UN R15B PC4",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R16B PC5",
"versionType": "custom"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UNEM",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "UNEM R16B PC2",
"versionType": "custom"
},
{
"lessThanOrEqual": "UNEM R16B PC4",
"status": "unaffected",
"version": "UNEM R16B PC3",
"versionType": "custom"
},
{
"status": "affected",
"version": "UNEM R15B PC4",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "UNEM R16B PC5",
"versionType": "custom"
},
{
"status": "affected",
"version": "UNEM R16A"
},
{
"status": "affected",
"version": "UNEM R15A"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that\nif exploited will generally lead to a denial of service but can be used \nto execute arbitrary code, which is usually outside the scope of a\nprogram\u0027s implicit security policy"
}
],
"value": "A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that\nif exploited will generally lead to a denial of service but can be used \nto execute arbitrary code, which is usually outside the scope of a\nprogram\u0027s implicit security policy"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T13:59:18.165Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000201\u0026languageCode=en\u0026Preview=true"
},
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000194\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-2011",
"datePublished": "2024-06-11T13:24:58.764Z",
"dateReserved": "2024-02-29T13:42:05.971Z",
"dateUpdated": "2024-08-01T18:56:22.675Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2462 (GCVE-0-2024-2462)
Vulnerability from nvd – Published: 2024-06-11 12:48 – Updated: 2024-08-01 19:11
VLAI
EPSS
VEX
Summary
Allow attackers to intercept or falsify data exchanges between the client
and the server
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-12 18:31 UTC
CWE
- CWE-297 - Improper Validation of Certificate with Host Mismatch
Assigner
Hitachi Energy
CNA
References
1 reference
Impacted products
12 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | FOXMAN-UN |
Affected:
0 , ≤ FOXMAN-UN R16B PC2
(custom)
Unaffected: FOXMAN-UN R16B PC3 (custom) Affected: 0 , ≤ FOXMAN-UN R15B PC4 (custom) Unaffected: FOXMAN-UN R15B PC5 (custom) Affected: FOXMAN-UN R16A (custom) Affected: FOXMAN-UN R15A (custom) |
|
| Hitachi Energy | FOX61x |
Affected:
0 , < FOX61x R16B
(custom)
Unaffected: FOX61x R16B (custom) |
|
| Hitachi Energy | FOXCST |
Affected:
0 , < FOXCST_16.2.1
(custom)
Unaffected: FOXCST_16.2.1 (custom) |
|
| Hitachi Energy | UNEM |
Affected:
0 , ≤ UNEM R16B PC2
(custom)
Unaffected: UNEM R16B PC3 (custom) Affected: 0 , ≤ UNEM R15B PC4 (custom) Unaffected: UNEM R15B PC5 (custom) Affected: UNEM R16A (custom) Affected: UNEM R15A (custom) |
|
| Hitachi Energy | XMC20 |
Affected:
R16B
(custom)
|
|
| Hitachi Energy | ECST |
Affected:
ECST_16.2.1
(custom)
|
|
| hitachi_energy | foxman-un |
Affected:
0 , ≤ FOXMAN-UN R16B PC2
(custom)
Unaffected: FOXMAN-UN R16B PC3 Affected: 0 , ≤ FOXMAN-UN R15B PC4 (custom) Unaffected: FOXMAN-UN R15B PC5 Affected: FOXMAN-UN R16A Affected: FOXMAN-UN R15A cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:* |
|
| hitachi_energy | fox61x |
Affected:
0 , < FOX61x R16B
(custom)
Unaffected: FOX61x R16B cpe:2.3:a:hitachi_energy:fox61x:*:*:*:*:*:*:*:* |
|
| hitachi_energy | foxcst |
Affected:
0 , < FOXCST_16.2.1
(custom)
Unaffected: FOXCST_16.2.1 cpe:2.3:a:hitachi_energy:foxcst:*:*:*:*:*:*:*:* |
|
| hitachi_energy | unem |
Affected:
0 , ≤ UNEM R16B PC2
(custom)
Unaffected: UNEM R16B PC3 Affected: 0 , ≤ UNEM R15B PC4 (custom) Unaffected: UNEM R15B PC5 Affected: UNEM R16A Affected: UNEM R15A cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:* |
|
| hitachi_energy | xmc20 |
Affected:
R16B
cpe:2.3:a:hitachi_energy:xmc20:*:*:*:*:*:*:*:* |
|
| hitachi_energy | ecst |
Affected:
ECST_16.2.1
cpe:2.3:a:hitachi_energy:ecst:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "foxman-un",
"vendor": "hitachi_energy",
"versions": [
{
"lessThanOrEqual": "FOXMAN-UN R16B PC2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R16B PC3"
},
{
"lessThanOrEqual": "FOXMAN-UN R15B PC4",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R15B PC5"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:fox61x:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "fox61x",
"vendor": "hitachi_energy",
"versions": [
{
"lessThan": "FOX61x R16B",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOX61x R16B"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:foxcst:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "foxcst",
"vendor": "hitachi_energy",
"versions": [
{
"lessThan": "FOXCST_16.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXCST_16.2.1"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unem",
"vendor": "hitachi_energy",
"versions": [
{
"lessThanOrEqual": "UNEM R16B PC2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "UNEM R16B PC3"
},
{
"lessThanOrEqual": "UNEM R15B PC4",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "UNEM R15B PC5"
},
{
"status": "affected",
"version": "UNEM R16A"
},
{
"status": "affected",
"version": "UNEM R15A"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:xmc20:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "xmc20",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "R16B"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:ecst:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ecst",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "ECST_16.2.1"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2462",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T18:31:01.584910Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T19:06:16.825Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:11:53.576Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000198\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FOXMAN-UN",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "FOXMAN-UN R16B PC2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R16B PC3",
"versionType": "custom"
},
{
"lessThanOrEqual": "FOXMAN-UN R15B PC4",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R15B PC5",
"versionType": "custom"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A",
"versionType": "custom"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FOX61x",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThan": "FOX61x R16B",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOX61x R16B",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FOXCST",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThan": "FOXCST_16.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXCST_16.2.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UNEM",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "UNEM R16B PC2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "UNEM R16B PC3",
"versionType": "custom"
},
{
"lessThanOrEqual": "UNEM R15B PC4",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "UNEM R15B PC5",
"versionType": "custom"
},
{
"status": "affected",
"version": "UNEM R16A",
"versionType": "custom"
},
{
"status": "affected",
"version": "UNEM R15A",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "XMC20",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "R16B",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ECST",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "ECST_16.2.1",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Allow attackers to intercept or falsify data exchanges between the client \nand the server\n\n"
}
],
"value": "Allow attackers to intercept or falsify data exchanges between the client \nand the server"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "PHYSICAL",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:A/VC:L/VI:N/VA:H/SC:L/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-297",
"description": "CWE-297 Improper Validation of Certificate with Host Mismatch",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T12:48:57.963Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000198\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-2462",
"datePublished": "2024-06-11T12:48:57.963Z",
"dateReserved": "2024-03-14T17:09:59.755Z",
"dateUpdated": "2024-08-01T19:11:53.576Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0400 (GCVE-0-2024-0400)
Vulnerability from nvd – Published: 2024-03-27 02:03 – Updated: 2025-10-16 08:07
VLAI
EPSS
VEX
Summary
SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-06 18:54 UTC
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
Hitachi Energy
CNA
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | MACH SCM |
Affected:
4.0 , ≤ 4.38
(custom)
|
|
| hitachi_energy | mach_scm |
Affected:
4.0 , ≤ 4.38
(custom)
cpe:2.3:a:hitachi_energy:mach_scm:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:04:49.537Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_energy:mach_scm:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "mach_scm",
"vendor": "hitachi_energy",
"versions": [
{
"lessThanOrEqual": "4.38",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0400",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-06T18:54:08.600663Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-06T19:00:32.693Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MACH SCM",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "4.38",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability."
}
],
"value": "SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-551",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-551 Modify Existing Service"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-16T08:07:33.107Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-0400",
"datePublished": "2024-03-27T02:03:57.253Z",
"dateReserved": "2024-01-10T15:23:18.527Z",
"dateUpdated": "2025-10-16T08:07:33.107Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41153 (GCVE-0-2024-41153)
Vulnerability from cvelistv5 – Published: 2024-10-29 12:30 – Updated: 2025-11-04 16:00
VLAI
EPSS
VEX
Summary
Command injection vulnerability in the Edge Computing UI for the
TRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the
web UI can execute commands on the device with root privileges,
far more extensive than what the write privilege intends.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-29 13:54 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Hitachi Energy
CNA
References
1 reference
| URL | Tags |
|---|---|
| https://publisher.hitachienergy.com/preview?Docum… | vendor-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | TRO600 |
Affected:
9.1.0.0 , ≤ 9.2.0.0
(custom)
|
|
| hitachi_energy | tro600 |
Affected:
9.1.0.0 , ≤ 9.2.0.0
(custom)
cpe:2.3:a:hitachi_energy:tro600:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_energy:tro600:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tro600",
"vendor": "hitachi_energy",
"versions": [
{
"lessThanOrEqual": "9.2.0.0",
"status": "affected",
"version": "9.1.0.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41153",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-29T13:54:05.290769Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-04T16:00:52.178Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TRO600",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "9.2.0.0",
"status": "affected",
"version": "9.1.0.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Command injection vulnerability in the Edge Computing UI for the\nTRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the\nweb UI can execute commands on the device with root privileges,\nfar more extensive than what the write privilege intends.\n\n\u003cbr\u003e"
}
],
"value": "Command injection vulnerability in the Edge Computing UI for the\nTRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the\nweb UI can execute commands on the device with root privileges,\nfar more extensive than what the write privilege intends."
}
],
"impacts": [
{
"capecId": "CAPEC-248",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-248 Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-24T08:38:07.234Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-41153",
"datePublished": "2024-10-29T12:30:31.402Z",
"dateReserved": "2024-07-16T16:02:30.295Z",
"dateUpdated": "2025-11-04T16:00:52.178Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-28024 (GCVE-0-2024-28024)
Vulnerability from cvelistv5 – Published: 2024-06-11 18:17 – Updated: 2024-10-29 14:42
VLAI
EPSS
VEX
Summary
A vulnerability exists in the FOXMAN-UN/UNEM in which sensitive information is
stored in cleartext within a resource that might be accessible to another control sphere.
Severity
4.1 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-11 20:22 UTC
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
Hitachi Energy
CNA
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | FOXMAN-UN |
Affected:
FOXMAN-UN R16B
Affected: FOXMAN-UN R15B Affected: FOXMAN-UN R16A Affected: FOXMAN-UN R15A |
|
| Hitachi Energy | UNEM |
Affected:
UNEM R16B
Affected: UNEM R15B Affected: UNEM R16A Affected: UNEM R15A |
|
| hitachi_energy | foxman-un |
Affected:
FOXMAN-UN R16B
Affected: FOXMAN-UN R15B Affected: FOXMAN-UN R16A Affected: FOXMAN-UN R15A cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:* |
|
| hitachi_energy | unem |
Affected:
UNEM R16B
Affected: UNEM R15B Affected: UNEM R16A Affected: UNEM R15A cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "foxman-un",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "FOXMAN-UN R16B"
},
{
"status": "affected",
"version": "FOXMAN-UN R15B"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unem",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "UNEM R16B"
},
{
"status": "affected",
"version": "UNEM R15B"
},
{
"status": "affected",
"version": "UNEM R16A"
},
{
"status": "affected",
"version": "UNEM R15A"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-28024",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-11T20:22:36.317764Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T20:39:33.569Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:48:47.698Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000201\u0026languageCode=en\u0026Preview=true"
},
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000194\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FOXMAN-UN",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "FOXMAN-UN R16B"
},
{
"status": "affected",
"version": "FOXMAN-UN R15B"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UNEM",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "UNEM R16B"
},
{
"status": "affected",
"version": "UNEM R15B"
},
{
"status": "affected",
"version": "UNEM R16A"
},
{
"status": "affected",
"version": "UNEM R15A"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the FOXMAN-UN/UNEM in which sensitive information is \nstored in cleartext within a resource that might be accessible to another control sphere."
}
],
"value": "A vulnerability exists in the FOXMAN-UN/UNEM in which sensitive information is \nstored in cleartext within a resource that might be accessible to another control sphere."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-29T14:42:42.760Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000201\u0026languageCode=en\u0026Preview=true"
},
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000194\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-28024",
"datePublished": "2024-06-11T18:17:54.877Z",
"dateReserved": "2024-02-29T13:42:00.746Z",
"dateUpdated": "2024-10-29T14:42:42.760Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2011 (GCVE-0-2024-2011)
Vulnerability from cvelistv5 – Published: 2024-06-11 13:24 – Updated: 2024-08-01 18:56
VLAI
EPSS
VEX
Summary
A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that
if exploited will generally lead to a denial of service but can be used
to execute arbitrary code, which is usually outside the scope of a
program's implicit security policy
Severity
8.6 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-18 19:34 UTC
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
Hitachi Energy
CNA
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | FOXMAN-UN |
Affected:
FOXMAN-UN R16B PC2
(custom)
Unaffected: FOXMAN-UN R16B PC3 , ≤ FOXMAN-UN R16B PC4 (custom) Affected: FOXMAN-UN R15B PC4 (custom) Unaffected: FOXMAN-UN R16B PC5 (custom) Affected: FOXMAN-UN R16A Affected: FOXMAN-UN R15A |
|
| Hitachi Energy | UNEM |
Affected:
UNEM R16B PC2
(custom)
Unaffected: UNEM R16B PC3 , ≤ UNEM R16B PC4 (custom) Affected: UNEM R15B PC4 (custom) Unaffected: UNEM R16B PC5 (custom) Affected: UNEM R16A Affected: UNEM R15A |
|
| hitachi_energy | foxman-un |
Affected:
FOXMAN-UN R16B PC2
Unaffected: FOXMAN-UN R16B PC3 , ≤ FOXMAN-UN R16B PC4 (custom) Affected: FOXMAN-UN R15B PC4 Unaffected: FOXMAN-UN R16B PC5 Affected: FOXMAN-UN R16A Affected: FOXMAN-UN R15A cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:* |
|
| hitachi_energy | unem |
Affected:
UNEM R16B PC2
Unaffected: UNEM R16B PC3 , ≤ UNEM R16B PC4 (custom) Affected: UNEM R15B PC4 Unaffected: UNEM R16B PC5 Affected: UNEM R16A Affected: UNEM R15A cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "foxman-un",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "FOXMAN-UN R16B PC2"
},
{
"lessThanOrEqual": "FOXMAN-UN R16B PC4",
"status": "unaffected",
"version": "FOXMAN-UN R16B PC3",
"versionType": "custom"
},
{
"status": "affected",
"version": "FOXMAN-UN R15B PC4"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R16B PC5"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unem",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "UNEM R16B PC2"
},
{
"lessThanOrEqual": "UNEM R16B PC4",
"status": "unaffected",
"version": "UNEM R16B PC3",
"versionType": "custom"
},
{
"status": "affected",
"version": "UNEM R15B PC4"
},
{
"status": "unaffected",
"version": "UNEM R16B PC5"
},
{
"status": "affected",
"version": "UNEM R16A"
},
{
"status": "affected",
"version": "UNEM R15A"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2011",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-18T19:34:01.919299Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-18T19:57:39.468Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:56:22.675Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000201\u0026languageCode=en\u0026Preview=true"
},
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000194\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FOXMAN-UN",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "FOXMAN-UN R16B PC2",
"versionType": "custom"
},
{
"lessThanOrEqual": "FOXMAN-UN R16B PC4",
"status": "unaffected",
"version": "FOXMAN-UN R16B PC3",
"versionType": "custom"
},
{
"status": "affected",
"version": "FOXMAN-UN R15B PC4",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R16B PC5",
"versionType": "custom"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UNEM",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "UNEM R16B PC2",
"versionType": "custom"
},
{
"lessThanOrEqual": "UNEM R16B PC4",
"status": "unaffected",
"version": "UNEM R16B PC3",
"versionType": "custom"
},
{
"status": "affected",
"version": "UNEM R15B PC4",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "UNEM R16B PC5",
"versionType": "custom"
},
{
"status": "affected",
"version": "UNEM R16A"
},
{
"status": "affected",
"version": "UNEM R15A"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that\nif exploited will generally lead to a denial of service but can be used \nto execute arbitrary code, which is usually outside the scope of a\nprogram\u0027s implicit security policy"
}
],
"value": "A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that\nif exploited will generally lead to a denial of service but can be used \nto execute arbitrary code, which is usually outside the scope of a\nprogram\u0027s implicit security policy"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T13:59:18.165Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000201\u0026languageCode=en\u0026Preview=true"
},
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000194\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-2011",
"datePublished": "2024-06-11T13:24:58.764Z",
"dateReserved": "2024-02-29T13:42:05.971Z",
"dateUpdated": "2024-08-01T18:56:22.675Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2462 (GCVE-0-2024-2462)
Vulnerability from cvelistv5 – Published: 2024-06-11 12:48 – Updated: 2024-08-01 19:11
VLAI
EPSS
VEX
Summary
Allow attackers to intercept or falsify data exchanges between the client
and the server
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-12 18:31 UTC
CWE
- CWE-297 - Improper Validation of Certificate with Host Mismatch
Assigner
Hitachi Energy
CNA
References
1 reference
Impacted products
12 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | FOXMAN-UN |
Affected:
0 , ≤ FOXMAN-UN R16B PC2
(custom)
Unaffected: FOXMAN-UN R16B PC3 (custom) Affected: 0 , ≤ FOXMAN-UN R15B PC4 (custom) Unaffected: FOXMAN-UN R15B PC5 (custom) Affected: FOXMAN-UN R16A (custom) Affected: FOXMAN-UN R15A (custom) |
|
| Hitachi Energy | FOX61x |
Affected:
0 , < FOX61x R16B
(custom)
Unaffected: FOX61x R16B (custom) |
|
| Hitachi Energy | FOXCST |
Affected:
0 , < FOXCST_16.2.1
(custom)
Unaffected: FOXCST_16.2.1 (custom) |
|
| Hitachi Energy | UNEM |
Affected:
0 , ≤ UNEM R16B PC2
(custom)
Unaffected: UNEM R16B PC3 (custom) Affected: 0 , ≤ UNEM R15B PC4 (custom) Unaffected: UNEM R15B PC5 (custom) Affected: UNEM R16A (custom) Affected: UNEM R15A (custom) |
|
| Hitachi Energy | XMC20 |
Affected:
R16B
(custom)
|
|
| Hitachi Energy | ECST |
Affected:
ECST_16.2.1
(custom)
|
|
| hitachi_energy | foxman-un |
Affected:
0 , ≤ FOXMAN-UN R16B PC2
(custom)
Unaffected: FOXMAN-UN R16B PC3 Affected: 0 , ≤ FOXMAN-UN R15B PC4 (custom) Unaffected: FOXMAN-UN R15B PC5 Affected: FOXMAN-UN R16A Affected: FOXMAN-UN R15A cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:* |
|
| hitachi_energy | fox61x |
Affected:
0 , < FOX61x R16B
(custom)
Unaffected: FOX61x R16B cpe:2.3:a:hitachi_energy:fox61x:*:*:*:*:*:*:*:* |
|
| hitachi_energy | foxcst |
Affected:
0 , < FOXCST_16.2.1
(custom)
Unaffected: FOXCST_16.2.1 cpe:2.3:a:hitachi_energy:foxcst:*:*:*:*:*:*:*:* |
|
| hitachi_energy | unem |
Affected:
0 , ≤ UNEM R16B PC2
(custom)
Unaffected: UNEM R16B PC3 Affected: 0 , ≤ UNEM R15B PC4 (custom) Unaffected: UNEM R15B PC5 Affected: UNEM R16A Affected: UNEM R15A cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:* |
|
| hitachi_energy | xmc20 |
Affected:
R16B
cpe:2.3:a:hitachi_energy:xmc20:*:*:*:*:*:*:*:* |
|
| hitachi_energy | ecst |
Affected:
ECST_16.2.1
cpe:2.3:a:hitachi_energy:ecst:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_energy:foxman-un:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "foxman-un",
"vendor": "hitachi_energy",
"versions": [
{
"lessThanOrEqual": "FOXMAN-UN R16B PC2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R16B PC3"
},
{
"lessThanOrEqual": "FOXMAN-UN R15B PC4",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R15B PC5"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:fox61x:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "fox61x",
"vendor": "hitachi_energy",
"versions": [
{
"lessThan": "FOX61x R16B",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOX61x R16B"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:foxcst:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "foxcst",
"vendor": "hitachi_energy",
"versions": [
{
"lessThan": "FOXCST_16.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXCST_16.2.1"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:unem:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "unem",
"vendor": "hitachi_energy",
"versions": [
{
"lessThanOrEqual": "UNEM R16B PC2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "UNEM R16B PC3"
},
{
"lessThanOrEqual": "UNEM R15B PC4",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "UNEM R15B PC5"
},
{
"status": "affected",
"version": "UNEM R16A"
},
{
"status": "affected",
"version": "UNEM R15A"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:xmc20:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "xmc20",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "R16B"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi_energy:ecst:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "ecst",
"vendor": "hitachi_energy",
"versions": [
{
"status": "affected",
"version": "ECST_16.2.1"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2462",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-12T18:31:01.584910Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T19:06:16.825Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:11:53.576Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000198\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FOXMAN-UN",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "FOXMAN-UN R16B PC2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R16B PC3",
"versionType": "custom"
},
{
"lessThanOrEqual": "FOXMAN-UN R15B PC4",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXMAN-UN R15B PC5",
"versionType": "custom"
},
{
"status": "affected",
"version": "FOXMAN-UN R16A",
"versionType": "custom"
},
{
"status": "affected",
"version": "FOXMAN-UN R15A",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FOX61x",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThan": "FOX61x R16B",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOX61x R16B",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FOXCST",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThan": "FOXCST_16.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "FOXCST_16.2.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UNEM",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "UNEM R16B PC2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "UNEM R16B PC3",
"versionType": "custom"
},
{
"lessThanOrEqual": "UNEM R15B PC4",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "UNEM R15B PC5",
"versionType": "custom"
},
{
"status": "affected",
"version": "UNEM R16A",
"versionType": "custom"
},
{
"status": "affected",
"version": "UNEM R15A",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "XMC20",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "R16B",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ECST",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "ECST_16.2.1",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Allow attackers to intercept or falsify data exchanges between the client \nand the server\n\n"
}
],
"value": "Allow attackers to intercept or falsify data exchanges between the client \nand the server"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "PHYSICAL",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:A/VC:L/VI:N/VA:H/SC:L/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-297",
"description": "CWE-297 Improper Validation of Certificate with Host Mismatch",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-11T12:48:57.963Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000198\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-2462",
"datePublished": "2024-06-11T12:48:57.963Z",
"dateReserved": "2024-03-14T17:09:59.755Z",
"dateUpdated": "2024-08-01T19:11:53.576Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0400 (GCVE-0-2024-0400)
Vulnerability from cvelistv5 – Published: 2024-03-27 02:03 – Updated: 2025-10-16 08:07
VLAI
EPSS
VEX
Summary
SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-06 18:54 UTC
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
Hitachi Energy
CNA
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi Energy | MACH SCM |
Affected:
4.0 , ≤ 4.38
(custom)
|
|
| hitachi_energy | mach_scm |
Affected:
4.0 , ≤ 4.38
(custom)
cpe:2.3:a:hitachi_energy:mach_scm:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:04:49.537Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_energy:mach_scm:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "mach_scm",
"vendor": "hitachi_energy",
"versions": [
{
"lessThanOrEqual": "4.38",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0400",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-06T18:54:08.600663Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-06T19:00:32.693Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MACH SCM",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "4.38",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability."
}
],
"value": "SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-551",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-551 Modify Existing Service"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-16T08:07:33.107Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-0400",
"datePublished": "2024-03-27T02:03:57.253Z",
"dateReserved": "2024-01-10T15:23:18.527Z",
"dateUpdated": "2025-10-16T08:07:33.107Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}