Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
1 vulnerability by electra-air
CVE-2023-24503 (GCVE-0-2023-24503)
Vulnerability from cvelistv5 – Published: 2023-04-17 00:00 – Updated: 2025-02-06 15:18
VLAI?
Title
Electra Smart Kit for Split AC – Adjacent attacker may cause the unit to load unauthorized FW
Summary
Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW.
Severity ?
7.5 (High)
CWE
- Adjacent attacker may cause the unit to load unauthorized FW
Assigner
References
Impacted products
Date Public ?
2023-04-17 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:56:04.348Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.gov.il/en/Departments/faq/cve_advisories"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-24503",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-06T15:17:49.550387Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T15:18:56.447Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "OSK201",
"vendor": "Electra",
"versions": [
{
"lessThan": "Update to the latest version*",
"status": "affected",
"version": "Update to the latest version",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lev Aronsky, Idan Strovinsky"
}
],
"datePublic": "2023-04-17T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Electra Central AC unit \u2013 Adjacent attacker may cause the unit to load unauthorized FW."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Adjacent attacker may cause the unit to load unauthorized FW",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-17T00:00:00.000Z",
"orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
"shortName": "INCD"
},
"references": [
{
"url": "https://www.gov.il/en/Departments/faq/cve_advisories"
}
],
"source": {
"defect": [
"ILVN-2023-0090"
],
"discovery": "UNKNOWN"
},
"title": " Electra Smart Kit for Split AC \u2013 Adjacent attacker may cause the unit to load unauthorized FW",
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
"assignerShortName": "INCD",
"cveId": "CVE-2023-24503",
"datePublished": "2023-04-17T00:00:00.000Z",
"dateReserved": "2023-01-24T00:00:00.000Z",
"dateUpdated": "2025-02-06T15:18:56.447Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}