Search

Find a vulnerability

Search criteria

    73 vulnerabilities by Lantronix

    CVE-2026-91191 (GCVE-0-2026-91191)

    Vulnerability from nvd – Published: 2026-09-29 21:04 – Updated: 2026-09-29 21:04
    VLAI
    Title
    Lantronix G520 Series Cellular Gateway Improper Verification of Cryptographic Signature
    Summary
    The device's update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation.
    CWE
    Impacted products
    Vendor Product Version
    Lantronix G520 Series Affected: 2.6.0.4R6 stable
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "G520 Series",
              "vendor": "Lantronix",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.4R6 stable"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Ievgen Bondarenko reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The device\u0027s update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation."
                }
              ],
              "value": "The device\u0027s update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-29T21:04:52.546Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528"
            },
            {
              "url": "https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-01"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-01.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\u003cbr\u003e\u003cdiv\u003e\u003ca href=\"https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\"\u003ehttps://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\u003c/a\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\n\u003cp\u003eFor more information, see the Lantronix Vulnerability Library.\u003cbr\u003e\u003ca href=\"https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\"\u003ehttps://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\u003cbr\u003e\u003ca href=\"mailto:Support@lantronix.com\"\u003emailto:Support@lantronix.com\u003c/a\u003e\u003c/p\u003e\n\n\u003c/div\u003e"
                }
              ],
              "value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\n https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528 \n\n\n\n\n\n\n\nFor more information, see the Lantronix Vulnerability Library.\n https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/ \n\n\n\nFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\n mailto:Support@lantronix.com"
            }
          ],
          "source": {
            "advisory": "ICSA-26-272-01",
            "discovery": "EXTERNAL"
          },
          "title": "Lantronix G520 Series Cellular Gateway Improper Verification of Cryptographic Signature",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-91191",
        "datePublished": "2026-09-29T21:04:52.546Z",
        "dateReserved": "2026-09-17T19:24:31.384Z",
        "dateUpdated": "2026-09-29T21:04:52.546Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-84409 (GCVE-0-2026-84409)

    Vulnerability from nvd – Published: 2026-09-29 21:02 – Updated: 2026-09-29 21:02
    VLAI
    Title
    Lantronix G520 Series Cellular Gateway Cross-site Scripting
    Summary
    The device's update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker‑controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system‑level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device.
    CWE
    Impacted products
    Vendor Product Version
    Lantronix G520 Series Affected: 2.6.0.4R6 stable
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "G520 Series",
              "vendor": "Lantronix",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.4R6 stable"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Ievgen Bondarenko reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The device\u0027s update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker\u2011controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system\u2011level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device."
                }
              ],
              "value": "The device\u0027s update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker\u2011controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system\u2011level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-29T21:02:09.711Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528"
            },
            {
              "url": "https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-01"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-01.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\u003cbr\u003e\u003cdiv\u003e\u003ca href=\"https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\"\u003ehttps://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\u003c/a\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\n\u003cp\u003eFor more information, see the Lantronix Vulnerability Library.\u003cbr\u003e\u003ca href=\"https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\"\u003ehttps://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\u003cbr\u003e\u003ca href=\"mailto:Support@lantronix.com\"\u003emailto:Support@lantronix.com\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e\u003c/div\u003e"
                }
              ],
              "value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\n https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528 \n\n\n\n\n\n\n\nFor more information, see the Lantronix Vulnerability Library.\n https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/ \n\n\n\nFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\n mailto:Support@lantronix.com"
            }
          ],
          "source": {
            "advisory": "ICSA-26-272-01",
            "discovery": "EXTERNAL"
          },
          "title": "Lantronix G520 Series Cellular Gateway Cross-site Scripting",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-84409",
        "datePublished": "2026-09-29T21:02:09.711Z",
        "dateReserved": "2026-09-17T19:24:31.388Z",
        "dateUpdated": "2026-09-29T21:02:09.711Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80156 (GCVE-0-2026-80156)

    Vulnerability from nvd – Published: 2026-09-22 15:23 – Updated: 2026-09-24 19:11
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices Arbitrary File Write via Upload Filename Validation Bypass
    Summary
    Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device's filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-23 15:42 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80156",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-23T15:42:01.037508Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-23T15:42:10.927Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device\u0027s filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:11:50.183Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-arbitrary-file-write-via-upload-filename-validation-bypass"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices Arbitrary File Write via Upload Filename Validation Bypass",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80156",
        "datePublished": "2026-09-22T15:23:24.784Z",
        "dateReserved": "2026-08-25T20:43:54.262Z",
        "dateUpdated": "2026-09-24T19:11:50.183Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80155 (GCVE-0-2026-80155)

    Vulnerability from nvd – Published: 2026-09-22 15:22 – Updated: 2026-09-24 19:11
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices Unauthenticated Authentication Bypass via snprintf Path Truncation
    Summary
    Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain an authentication bypass vulnerability in the web management portal upload endpoint that allows unauthenticated attackers to read sensitive configuration files and upload files to arbitrary filesystem locations, leading to remote code execution. The web configuration server constructs the session cookie file path using snprintf with a fixed-size buffer; by supplying a cookie value of a specific length an attacker causes the path to truncate at the required delimiter and leverages path traversal to redirect authentication validation to an arbitrary on-disk file such as the local user database, bypassing all session checks. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 15:42 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80155",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T15:42:37.923706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T15:43:00.393Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain an authentication bypass vulnerability in the web management portal upload endpoint that allows unauthenticated attackers to read sensitive configuration files and upload files to arbitrary filesystem locations, leading to remote code execution. The web configuration server constructs the session cookie file path using snprintf with a fixed-size buffer; by supplying a cookie value of a specific length an attacker causes the path to truncate at the required delimiter and leverages path traversal to redirect authentication validation to an arbitrary on-disk file such as the local user database, bypassing all session checks. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:11:02.375Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-unauthenticated-authentication-bypass-via-snprintf-path-truncation"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices Unauthenticated Authentication Bypass via snprintf Path Truncation",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80155",
        "datePublished": "2026-09-22T15:22:57.059Z",
        "dateReserved": "2026-08-25T20:43:54.262Z",
        "dateUpdated": "2026-09-24T19:11:02.375Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80154 (GCVE-0-2026-80154)

    Vulnerability from nvd – Published: 2026-09-22 15:22 – Updated: 2026-09-24 19:10
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices Predictable Session Token with Validation Bypass
    Summary
    All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 17:22 UTC
    CWE
    • CWE-330 - Use of Insufficiently Random Values
    References
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80154",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T17:22:31.916185Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T17:44:14.925Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 8.9,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-330",
                  "description": "Use of Insufficiently Random Values",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:10:15.088Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-predictable-session-token-with-validation-bypass"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices Predictable Session Token with Validation Bypass",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80154",
        "datePublished": "2026-09-22T15:22:33.748Z",
        "dateReserved": "2026-08-25T20:43:54.262Z",
        "dateUpdated": "2026-09-24T19:10:15.088Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80152 (GCVE-0-2026-80152)

    Vulnerability from nvd – Published: 2026-09-22 15:22 – Updated: 2026-09-26 13:29
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices OS Command Injection via set script schedule
    Summary
    Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set script schedule command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 15:49 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80152",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T15:49:36.568082Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T15:52:24.941Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set script schedule command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-26T13:29:54.538Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-os-command-injection-via-set-script-schedule"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices OS Command Injection via set script schedule",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80152",
        "datePublished": "2026-09-22T15:22:09.965Z",
        "dateReserved": "2026-08-25T20:43:54.262Z",
        "dateUpdated": "2026-09-26T13:29:54.538Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80151 (GCVE-0-2026-80151)

    Vulnerability from nvd – Published: 2026-09-22 15:21 – Updated: 2026-09-26 13:29
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices OS Command Injection via set nfs download
    Summary
    Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set nfs download command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-25 23:35 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80151",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-25T23:35:00.564701Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-25T23:35:17.426Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set nfs download command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-26T13:29:53.855Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-os-command-injection-via-set-nfs-download"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices OS Command Injection via set nfs download",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80151",
        "datePublished": "2026-09-22T15:21:45.246Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-26T13:29:53.855Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80150 (GCVE-0-2026-80150)

    Vulnerability from nvd – Published: 2026-09-22 15:21 – Updated: 2026-09-26 13:29
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices WebTelnet SSRF via rooturl Parameter
    Summary
    Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish Telnet connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the Telnet terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-23 15:46 UTC
    CWE
    • CWE-918 - Server-Side Request Forgery (SSRF)
    Impacted products
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80150",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-23T15:46:31.921852Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-23T15:46:38.366Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish Telnet connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the Telnet terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-918",
                  "description": "Server-Side Request Forgery (SSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-26T13:29:53.179Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webtelnet-ssrf-via-rooturl-parameter"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices WebTelnet SSRF via rooturl Parameter",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80150",
        "datePublished": "2026-09-22T15:21:22.223Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-26T13:29:53.179Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80149 (GCVE-0-2026-80149)

    Vulnerability from nvd – Published: 2026-09-22 15:20 – Updated: 2026-09-26 13:29
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via rooturl Parameter
    Summary
    Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the SSH terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 15:41 UTC
    CWE
    • CWE-918 - Server-Side Request Forgery (SSRF)
    Impacted products
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80149",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T15:41:42.950532Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T15:42:08.210Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the SSH terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-918",
                  "description": "Server-Side Request Forgery (SSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-26T13:29:52.466Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webssh-ssrf-via-rooturl-parameter"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via rooturl Parameter",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80149",
        "datePublished": "2026-09-22T15:20:57.823Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-26T13:29:52.466Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80148 (GCVE-0-2026-80148)

    Vulnerability from nvd – Published: 2026-09-22 15:20 – Updated: 2026-09-26 13:29
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via Username Truncation
    Summary
    Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd builds its SSH connection target using a snprintf call with user-supplied input; by supplying an overlong username string an attacker causes the device IP suffix to be truncated, redirecting the resulting connection to an arbitrary host. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 17:22 UTC
    CWE
    • CWE-918 - Server-Side Request Forgery (SSRF)
    Impacted products
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80148",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T17:22:22.576164Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T17:44:20.907Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd builds its SSH connection target using a snprintf call with user-supplied input; by supplying an overlong username string an attacker causes the device IP suffix to be truncated, redirecting the resulting connection to an arbitrary host. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-918",
                  "description": "Server-Side Request Forgery (SSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-26T13:29:51.780Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webssh-ssrf-via-username-truncation"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via Username Truncation",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80148",
        "datePublished": "2026-09-22T15:20:33.864Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-26T13:29:51.780Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80147 (GCVE-0-2026-80147)

    Vulnerability from nvd – Published: 2026-09-22 15:20 – Updated: 2026-09-24 19:04
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom write
    Summary
    Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 16:02 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80147",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T16:02:05.783698Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T16:04:04.161Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:04:09.218Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-write"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom write",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80147",
        "datePublished": "2026-09-22T15:20:01.691Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-24T19:04:09.218Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80146 (GCVE-0-2026-80146)

    Vulnerability from nvd – Published: 2026-09-22 15:19 – Updated: 2026-09-25 23:34
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom read
    Summary
    Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom read command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-25 23:33 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80146",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-25T23:33:56.909340Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-25T23:34:09.518Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom read command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:03:26.826Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-read"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom read",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80146",
        "datePublished": "2026-09-22T15:19:38.818Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-25T23:34:09.518Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80145 (GCVE-0-2026-80145)

    Vulnerability from nvd – Published: 2026-09-22 15:18 – Updated: 2026-09-24 19:02
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices CLI Command Injection via set cifs password
    Summary
    Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-23 15:47 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80145",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-23T15:47:50.948392Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-23T15:47:57.416Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:02:15.483Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-set-cifs-password"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via set cifs password",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80145",
        "datePublished": "2026-09-22T15:18:34.859Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-24T19:02:15.483Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80144 (GCVE-0-2026-80144)

    Vulnerability from nvd – Published: 2026-09-22 15:17 – Updated: 2026-09-24 19:02
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom write
    Summary
    Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom write command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 15:43 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80144",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T15:43:42.780303Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T15:43:55.512Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom write command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:02:33.612Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-mfc-eeprom-write"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom write",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80144",
        "datePublished": "2026-09-22T15:17:45.543Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-24T19:02:33.612Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80143 (GCVE-0-2026-80143)

    Vulnerability from nvd – Published: 2026-09-22 15:17 – Updated: 2026-09-24 19:02
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom read
    Summary
    Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom read command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 17:22 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80143",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T17:22:12.191184Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T17:44:26.836Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom read command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:02:44.035Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-mfc-eeprom-read"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom read",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80143",
        "datePublished": "2026-09-22T15:17:21.739Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-24T19:02:44.035Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-91191 (GCVE-0-2026-91191)

    Vulnerability from cvelistv5 – Published: 2026-09-29 21:04 – Updated: 2026-09-29 21:04
    VLAI
    Title
    Lantronix G520 Series Cellular Gateway Improper Verification of Cryptographic Signature
    Summary
    The device's update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation.
    CWE
    Impacted products
    Vendor Product Version
    Lantronix G520 Series Affected: 2.6.0.4R6 stable
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "G520 Series",
              "vendor": "Lantronix",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.4R6 stable"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Ievgen Bondarenko reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The device\u0027s update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation."
                }
              ],
              "value": "The device\u0027s update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packages from a writable, unsigned feed. Separately, the publicly distributed SDK contains the production private key whose corresponding public key is trusted by both stable and beta firmware builds. Either issue undermines package authenticity, and together they allow an attacker to provide packages that appear valid to the system. Even if signature enforcement is restored, the exposed production key enables an attacker to generate signatures that the device will continue to trust. An attacker who can supply a malicious package may be able to execute arbitrary code with root privileges during installation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-29T21:04:52.546Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528"
            },
            {
              "url": "https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-01"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-01.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\u003cbr\u003e\u003cdiv\u003e\u003ca href=\"https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\"\u003ehttps://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\u003c/a\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\n\u003cp\u003eFor more information, see the Lantronix Vulnerability Library.\u003cbr\u003e\u003ca href=\"https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\"\u003ehttps://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\u003cbr\u003e\u003ca href=\"mailto:Support@lantronix.com\"\u003emailto:Support@lantronix.com\u003c/a\u003e\u003c/p\u003e\n\n\u003c/div\u003e"
                }
              ],
              "value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\n https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528 \n\n\n\n\n\n\n\nFor more information, see the Lantronix Vulnerability Library.\n https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/ \n\n\n\nFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\n mailto:Support@lantronix.com"
            }
          ],
          "source": {
            "advisory": "ICSA-26-272-01",
            "discovery": "EXTERNAL"
          },
          "title": "Lantronix G520 Series Cellular Gateway Improper Verification of Cryptographic Signature",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-91191",
        "datePublished": "2026-09-29T21:04:52.546Z",
        "dateReserved": "2026-09-17T19:24:31.384Z",
        "dateUpdated": "2026-09-29T21:04:52.546Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-84409 (GCVE-0-2026-84409)

    Vulnerability from cvelistv5 – Published: 2026-09-29 21:02 – Updated: 2026-09-29 21:02
    VLAI
    Title
    Lantronix G520 Series Cellular Gateway Cross-site Scripting
    Summary
    The device's update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker‑controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system‑level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device.
    CWE
    Impacted products
    Vendor Product Version
    Lantronix G520 Series Affected: 2.6.0.4R6 stable
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "G520 Series",
              "vendor": "Lantronix",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.4R6 stable"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Ievgen Bondarenko reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The device\u0027s update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker\u2011controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system\u2011level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device."
                }
              ],
              "value": "The device\u0027s update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interface responsible for displaying update information inserts that value directly into the page as HTML. This behavior allows attacker\u2011controlled metadata to be interpreted as script content. In addition, the same authenticated origin provides an interface capable of executing system\u2011level commands with root privileges. An attacker able to influence update metadata could exploit these conditions to execute arbitrary code within the administrative context of the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-29T21:02:09.711Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528"
            },
            {
              "url": "https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-01"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-272-01.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\u003cbr\u003e\u003cdiv\u003e\u003ca href=\"https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\"\u003ehttps://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528\u003c/a\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\n\u003cp\u003eFor more information, see the Lantronix Vulnerability Library.\u003cbr\u003e\u003ca href=\"https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\"\u003ehttps://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\u003cbr\u003e\u003ca href=\"mailto:Support@lantronix.com\"\u003emailto:Support@lantronix.com\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e\u003c/div\u003e"
                }
              ],
              "value": "Lantronix has addressed the reported issues with release version 2.6.0.7R6 which is available on their website.\n https://ltrxdev.atlassian.net/wiki/spaces/LTRXTS/pages/1889828865/Latest+firmware+for+the+G520+Series+G526+G526RP+G527+G528 \n\n\n\n\n\n\n\nFor more information, see the Lantronix Vulnerability Library.\n https://www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-policy/vulnerability-library/ \n\n\n\nFor more information or technical assistance, contact Lantronix support: Support@lantronix.com\n mailto:Support@lantronix.com"
            }
          ],
          "source": {
            "advisory": "ICSA-26-272-01",
            "discovery": "EXTERNAL"
          },
          "title": "Lantronix G520 Series Cellular Gateway Cross-site Scripting",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-84409",
        "datePublished": "2026-09-29T21:02:09.711Z",
        "dateReserved": "2026-09-17T19:24:31.388Z",
        "dateUpdated": "2026-09-29T21:02:09.711Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80156 (GCVE-0-2026-80156)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:23 – Updated: 2026-09-24 19:11
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices Arbitrary File Write via Upload Filename Validation Bypass
    Summary
    Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device's filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-23 15:42 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80156",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-23T15:42:01.037508Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-23T15:42:10.927Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device\u0027s filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:11:50.183Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-arbitrary-file-write-via-upload-filename-validation-bypass"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices Arbitrary File Write via Upload Filename Validation Bypass",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80156",
        "datePublished": "2026-09-22T15:23:24.784Z",
        "dateReserved": "2026-08-25T20:43:54.262Z",
        "dateUpdated": "2026-09-24T19:11:50.183Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80155 (GCVE-0-2026-80155)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:22 – Updated: 2026-09-24 19:11
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices Unauthenticated Authentication Bypass via snprintf Path Truncation
    Summary
    Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain an authentication bypass vulnerability in the web management portal upload endpoint that allows unauthenticated attackers to read sensitive configuration files and upload files to arbitrary filesystem locations, leading to remote code execution. The web configuration server constructs the session cookie file path using snprintf with a fixed-size buffer; by supplying a cookie value of a specific length an attacker causes the path to truncate at the required delimiter and leverages path traversal to redirect authentication validation to an arbitrary on-disk file such as the local user database, bypassing all session checks. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 15:42 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80155",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T15:42:37.923706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T15:43:00.393Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain an authentication bypass vulnerability in the web management portal upload endpoint that allows unauthenticated attackers to read sensitive configuration files and upload files to arbitrary filesystem locations, leading to remote code execution. The web configuration server constructs the session cookie file path using snprintf with a fixed-size buffer; by supplying a cookie value of a specific length an attacker causes the path to truncate at the required delimiter and leverages path traversal to redirect authentication validation to an arbitrary on-disk file such as the local user database, bypassing all session checks. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:11:02.375Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-unauthenticated-authentication-bypass-via-snprintf-path-truncation"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices Unauthenticated Authentication Bypass via snprintf Path Truncation",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80155",
        "datePublished": "2026-09-22T15:22:57.059Z",
        "dateReserved": "2026-08-25T20:43:54.262Z",
        "dateUpdated": "2026-09-24T19:11:02.375Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80154 (GCVE-0-2026-80154)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:22 – Updated: 2026-09-24 19:10
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices Predictable Session Token with Validation Bypass
    Summary
    All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 17:22 UTC
    CWE
    • CWE-330 - Use of Insufficiently Random Values
    References
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80154",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T17:22:31.916185Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T17:44:14.925Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 8.9,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-330",
                  "description": "Use of Insufficiently Random Values",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:10:15.088Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-predictable-session-token-with-validation-bypass"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices Predictable Session Token with Validation Bypass",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80154",
        "datePublished": "2026-09-22T15:22:33.748Z",
        "dateReserved": "2026-08-25T20:43:54.262Z",
        "dateUpdated": "2026-09-24T19:10:15.088Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80152 (GCVE-0-2026-80152)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:22 – Updated: 2026-09-26 13:29
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices OS Command Injection via set script schedule
    Summary
    Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set script schedule command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 15:49 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80152",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T15:49:36.568082Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T15:52:24.941Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set script schedule command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-26T13:29:54.538Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-os-command-injection-via-set-script-schedule"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices OS Command Injection via set script schedule",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80152",
        "datePublished": "2026-09-22T15:22:09.965Z",
        "dateReserved": "2026-08-25T20:43:54.262Z",
        "dateUpdated": "2026-09-26T13:29:54.538Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80151 (GCVE-0-2026-80151)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:21 – Updated: 2026-09-26 13:29
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices OS Command Injection via set nfs download
    Summary
    Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set nfs download command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-25 23:35 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80151",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-25T23:35:00.564701Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-25T23:35:17.426Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set nfs download command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-26T13:29:53.855Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-os-command-injection-via-set-nfs-download"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices OS Command Injection via set nfs download",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80151",
        "datePublished": "2026-09-22T15:21:45.246Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-26T13:29:53.855Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80150 (GCVE-0-2026-80150)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:21 – Updated: 2026-09-26 13:29
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices WebTelnet SSRF via rooturl Parameter
    Summary
    Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish Telnet connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the Telnet terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-23 15:46 UTC
    CWE
    • CWE-918 - Server-Side Request Forgery (SSRF)
    Impacted products
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80150",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-23T15:46:31.921852Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-23T15:46:38.366Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish Telnet connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the Telnet terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-918",
                  "description": "Server-Side Request Forgery (SSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-26T13:29:53.179Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webtelnet-ssrf-via-rooturl-parameter"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices WebTelnet SSRF via rooturl Parameter",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80150",
        "datePublished": "2026-09-22T15:21:22.223Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-26T13:29:53.179Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80149 (GCVE-0-2026-80149)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:20 – Updated: 2026-09-26 13:29
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via rooturl Parameter
    Summary
    Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the SSH terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 15:41 UTC
    CWE
    • CWE-918 - Server-Side Request Forgery (SSRF)
    Impacted products
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80149",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T15:41:42.950532Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T15:42:08.210Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd uses the rooturl parameter from the web connection to determine its own IP address; by modifying this parameter an attacker redirects the SSH terminal connection to an arbitrary host or IP. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-918",
                  "description": "Server-Side Request Forgery (SSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-26T13:29:52.466Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webssh-ssrf-via-rooturl-parameter"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via rooturl Parameter",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80149",
        "datePublished": "2026-09-22T15:20:57.823Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-26T13:29:52.466Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80148 (GCVE-0-2026-80148)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:20 – Updated: 2026-09-26 13:29
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via Username Truncation
    Summary
    Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd builds its SSH connection target using a snprintf call with user-supplied input; by supplying an overlong username string an attacker causes the device IP suffix to be truncated, redirecting the resulting connection to an arbitrary host. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 17:22 UTC
    CWE
    • CWE-918 - Server-Side Request Forgery (SSRF)
    Impacted products
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80148",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T17:22:22.576164Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T17:44:20.907Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd builds its SSH connection target using a snprintf call with user-supplied input; by supplying an overlong username string an attacker causes the device IP suffix to be truncated, redirecting the resulting connection to an arbitrary host. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-918",
                  "description": "Server-Side Request Forgery (SSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-26T13:29:51.780Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-webssh-ssrf-via-username-truncation"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via Username Truncation",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80148",
        "datePublished": "2026-09-22T15:20:33.864Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-26T13:29:51.780Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80147 (GCVE-0-2026-80147)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:20 – Updated: 2026-09-24 19:04
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom write
    Summary
    Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 16:02 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80147",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T16:02:05.783698Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T16:04:04.161Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom write command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:04:09.218Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-write"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom write",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80147",
        "datePublished": "2026-09-22T15:20:01.691Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-24T19:04:09.218Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80146 (GCVE-0-2026-80146)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:19 – Updated: 2026-09-25 23:34
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom read
    Summary
    Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom read command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-25 23:33 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80146",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-25T23:33:56.909340Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-25T23:34:09.518Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a stack-based buffer overflow vulnerability that allows authenticated attackers to potentially execute arbitrary code by exploiting an undocumented mfc eeprom read command that copies unbounded user input into a bounded stack buffer before passing it to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and supply an oversized input to trigger the overflow, potentially achieving complete loss of confidentiality, integrity, and availability on the affected device and impacting downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:03:26.826Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-stack-based-buffer-overflow-via-mfc-eeprom-read"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices Stack-Based Buffer Overflow via mfc eeprom read",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80146",
        "datePublished": "2026-09-22T15:19:38.818Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-25T23:34:09.518Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80145 (GCVE-0-2026-80145)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:18 – Updated: 2026-09-24 19:02
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices CLI Command Injection via set cifs password
    Summary
    Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-23 15:47 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80145",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-23T15:47:50.948392Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-23T15:47:57.416Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:02:15.483Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-set-cifs-password"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via set cifs password",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80145",
        "datePublished": "2026-09-22T15:18:34.859Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-24T19:02:15.483Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80144 (GCVE-0-2026-80144)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:17 – Updated: 2026-09-24 19:02
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom write
    Summary
    Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom write command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 15:43 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80144",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T15:43:42.780303Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T15:43:55.512Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom write command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:02:33.612Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-mfc-eeprom-write"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom write",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80144",
        "datePublished": "2026-09-22T15:17:45.543Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-24T19:02:33.612Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80143 (GCVE-0-2026-80143)

    Vulnerability from cvelistv5 – Published: 2026-09-22 15:17 – Updated: 2026-09-24 19:02
    VLAI
    Title
    Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom read
    Summary
    Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom read command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-22 17:22 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Date Public
    2026-09-18 00:00
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80143",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-22T17:22:12.191184Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-22T17:44:26.836Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "SLC8000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG8500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EMG7500",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLB882",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SLCx-03",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLCx-02",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "status": "affected",
                  "version": "*",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SLC9000",
              "vendor": "LANTRONIX",
              "versions": [
                {
                  "lessThan": "9.7.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "RE/VRb"
            }
          ],
          "datePublic": "2026-09-18T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom read command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T19:02:44.035Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "Researcher Disclosure",
              "tags": [
                "technical-description"
              ],
              "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
            },
            {
              "name": "SLC8000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
            },
            {
              "name": "EMG8500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
            },
            {
              "name": "EMG7500 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
            },
            {
              "name": "SLC9000 Firmware",
              "tags": [
                "patch"
              ],
              "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-mfc-eeprom-read"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom read",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-80143",
        "datePublished": "2026-09-22T15:17:21.739Z",
        "dateReserved": "2026-08-25T20:43:54.261Z",
        "dateUpdated": "2026-09-24T19:02:44.035Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }