Search

Find a vulnerability

Search criteria

    3 vulnerabilities by LCDS Laquis

    GCVE-1988-2026-0409

    Vulnerability from gna-1988 – Published: 2026-10-02 04:57 – Updated: 2026-10-02 04:57
    VLAI
    Title
    [0day-rubbish] LCDS Laquis SCADA Unauthenticated /uploade.html file write chained with CMDEXT*.DLL autoload (9.8)
    Summary
    0day Rubbish Research Team is publicly disclosing a vulnerability in LCDS Laquis SCADA. Type: Unauthenticated /uploade.html file write chained with CMDEXT*.DLL autoload (CWE-434) CVSS: 9.8 (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) Impact: arbitrary native code execution inside the SCADA web and HMI process, which also hosts the Modbus TCP listener Authentication: unauthenticated (no password configured is the default) Full technical analysis and a reproducible proof-of-concept: https://0day-rubbish.com/blog/lcds-laquis-scada-unauth-uploade-cmdext-dll-rce Project archive (ongoing disclosure series): https://github.com/Exploit-Garbage/0day-Rubbish Vendor has been notified. CVE ID is pending. -- 0day Rubbish Research Team disclosure () 0day-rubbish com https://0day-rubbish.com _______________________________________________ Sent through the Full Disclosure mailing list https://nmap.org/mailman/listinfo/fulldisclosure Web Archives & RSS: https://seclists.org/fulldisclosure/
    Severity
    No CVSS data available.
    CWE
    Assigner
    VULNARCHIVE GNA GNA-1988
    GNA scorecard E 38/100 over 552 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Lcds Laquis SCADA Affected: unknown
    Create a notification for this product.

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "product": "SCADA",
              "vendor": "Lcds Laquis",
              "versions": [
                {
                  "status": "affected",
                  "version": "unknown"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "disclosure via Fulldisclosure"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "0day Rubbish Research Team is publicly disclosing a vulnerability in\nLCDS Laquis SCADA.\n\nType: Unauthenticated /uploade.html file write chained with CMDEXT*.DLL autoload (CWE-434)\nCVSS: 9.8 (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H)\nImpact: arbitrary native code execution inside the SCADA web and HMI process, which also hosts the Modbus TCP listener\nAuthentication: unauthenticated (no password configured is the default)\n\nFull technical analysis and a reproducible proof-of-concept:\n  https://0day-rubbish.com/blog/lcds-laquis-scada-unauth-uploade-cmdext-dll-rce\n\nProject archive (ongoing disclosure series):\n  https://github.com/Exploit-Garbage/0day-Rubbish\n\nVendor has been notified. CVE ID is pending.\n\n--\n0day Rubbish Research Team\ndisclosure () 0day-rubbish com\nhttps://0day-rubbish.com\n_______________________________________________\nSent through the Full Disclosure mailing list\nhttps://nmap.org/mailman/listinfo/fulldisclosure\nWeb Archives \u0026 RSS: https://seclists.org/fulldisclosure/"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "CWE-434",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T04:57:32Z",
            "orgId": "4e2abfbf-4a2a-4b76-a4e0-d77c18ba156c",
            "shortName": "VULNARCHIVE"
          },
          "references": [
            {
              "tags": [
                "technical-description",
                "exploit"
              ],
              "url": "https://vuln.freearchive.org/archive/full-disclosure/2026/Sep/51"
            },
            {
              "tags": [
                "technical-description"
              ],
              "url": "https://seclists.org/fulldisclosure/2026/Sep/51"
            },
            {
              "url": "https://0day-rubbish.com"
            },
            {
              "url": "https://0day-rubbish.com/blog/lcds-laquis-scada-unauth-uploade-cmdext-dll-rce"
            },
            {
              "url": "https://github.com/Exploit-Garbage/0day-Rubbish"
            },
            {
              "url": "https://nmap.org/mailman/listinfo/fulldisclosure"
            },
            {
              "url": "https://seclists.org/fulldisclosure/"
            }
          ],
          "source": {
            "defect": [
              "https://seclists.org/fulldisclosure/2026/Sep/51"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "[0day-rubbish] LCDS Laquis SCADA Unauthenticated /uploade.html file write chained with CMDEXT*.DLL autoload (9.8)",
          "x_gcve": [
            {
              "recordType": "advisory",
              "relationships": [],
              "vulnId": "GCVE-1988-2026-0409",
              "x_vulnarchive": {
                "archiveUrl": "https://vuln.freearchive.org/archive/full-disclosure/2026/Sep/51",
                "automated": true,
                "contentSha256": "f49df1a20f93abd04032c394ef7b18848a7a86bccf8a10960e47b717f37b4b3e",
                "evidenceScore": 10,
                "messageId": "",
                "originalUrl": "https://seclists.org/fulldisclosure/2026/Sep/51",
                "policy": "vulnarchive-1",
                "sourceFormat": "text/html",
                "sourcePublishedAt": "2026-09-20T12:18:26Z"
              }
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4e2abfbf-4a2a-4b76-a4e0-d77c18ba156c",
        "assignerShortName": "VULNARCHIVE",
        "datePublished": "2026-10-02T04:57:32Z",
        "dateUpdated": "2026-10-02T04:57:32Z",
        "state": "PUBLISHED",
        "vulnId": "GCVE-1988-2026-0409"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2018-18994 (GCVE-0-2018-18994)

    Vulnerability from nvd – Published: 2019-03-27 17:38 – Updated: 2024-08-05 11:23
    VLAI
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or allow data exfiltration.
    Severity
    No CVSS data available.
    CWE
    • CWE-125 - OUT-OF-BOUNDS READ CWE-125
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 349 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    LCDS Laquis LCDS Laquis SCADA Affected: All versions prior to version 4.1.0.4150
    Create a notification for this product.
    Date Public
    2019-01-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:23:08.915Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "LCDS Laquis",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "datePublic": "2019-01-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or allow data exfiltration."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "OUT-OF-BOUNDS READ CWE-125",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-03-27T17:38:14.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-18994",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LCDS Laquis SCADA",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to version 4.1.0.4150"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "LCDS Laquis"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or allow data exfiltration."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "OUT-OF-BOUNDS READ CWE-125"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-18994",
        "datePublished": "2019-03-27T17:38:14.000Z",
        "dateReserved": "2018-11-06T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:23:08.915Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18994 (GCVE-0-2018-18994)

    Vulnerability from cvelistv5 – Published: 2019-03-27 17:38 – Updated: 2024-08-05 11:23
    VLAI
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or allow data exfiltration.
    Severity
    No CVSS data available.
    CWE
    • CWE-125 - OUT-OF-BOUNDS READ CWE-125
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 349 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    LCDS Laquis LCDS Laquis SCADA Affected: All versions prior to version 4.1.0.4150
    Create a notification for this product.
    Date Public
    2019-01-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:23:08.915Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "LCDS Laquis",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "datePublic": "2019-01-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or allow data exfiltration."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "OUT-OF-BOUNDS READ CWE-125",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-03-27T17:38:14.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2018-18994",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LCDS Laquis SCADA",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to version 4.1.0.4150"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "LCDS Laquis"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or allow data exfiltration."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "OUT-OF-BOUNDS READ CWE-125"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-18994",
        "datePublished": "2019-03-27T17:38:14.000Z",
        "dateReserved": "2018-11-06T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:23:08.915Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }