Search
Find a vulnerability
Search criteria
22 vulnerabilities by Frauscher
FKIE_CVE-2023-5500
Vulnerability from fkie_nvd - Published: 2023-12-11 07:15 - Updated: 2026-06-17 06:48
Severity
Summary
This vulnerability allows an remote attacker with low privileges to misuse Improper Control of Generation of Code ('Code Injection') to gain full control of the affected device.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-049/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-049/ | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| frauscher | frauscher_diagnostic_system_102 | * | |
| frauscher | frauscher_diagnostic_system_102 | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "FDS102 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "2.10.1",
"status": "affected",
"version": "2.10.0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_102:*:*:*:*:*:fadc:*:*",
"matchCriteriaId": "2FE9E9D7-A692-4C03-883A-6C62DBE46DBD",
"versionEndExcluding": "2.10.2",
"versionStartIncluding": "2.10.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_102:*:*:*:*:*:fadci:*:*",
"matchCriteriaId": "D55CB7CF-AB9E-47C2-8E1F-F8AB89E37F7E",
"versionEndExcluding": "2.10.2",
"versionStartIncluding": "2.10.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows an remote attacker with low privileges to misuse Improper Control of Generation of Code (\u0027Code Injection\u0027) to gain full control of the affected device."
},
{
"lang": "es",
"value": "Esta vulnerabilidad permite a un atacante remoto con pocos privilegios hacer un uso indebido del control inadecuado de generaci\u00f3n de c\u00f3digo (\"inyecci\u00f3n de c\u00f3digo\") para obtener el control total del dispositivo afectado."
}
],
"id": "CVE-2023-5500",
"lastModified": "2026-06-17T06:48:43.510",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
},
"published": "2023-12-11T07:15:07.160",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-049/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-049/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-94"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-4292
Vulnerability from fkie_nvd - Published: 2023-09-21 07:15 - Updated: 2026-06-17 06:37
Severity
Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical log information.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://https://cert.vde.com/en/advisories/VDE-2023-038 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://https://cert.vde.com/en/advisories/VDE-2023-038 | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| frauscher | frauscher_diagnostic_system_101 | * | |
| frauscher | frauscher_diagnostic_system_101 | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "FDS101 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:*:*:*:*:*:fadc:*:*",
"matchCriteriaId": "8C27C13A-FDC8-4E2C-A4E0-324A29040DC5",
"versionEndIncluding": "1.4.24",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:*:*:*:*:*:fadci:*:*",
"matchCriteriaId": "65E1CCBA-51DB-439D-951F-1EC97EB9E58D",
"versionEndIncluding": "1.4.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical log information.\n\n\n\n"
},
{
"lang": "es",
"value": "Frauscher Sensortechnik GmbH FDS101 para FAdC/FAdCi v1.4.24 y todas las versiones anteriores son vulnerables a una vulnerabilidad de inyecci\u00f3n SQL a trav\u00e9s de par\u00e1metros manipulados de la interfaz web sin autenticaci\u00f3n. La base de datos contiene informaci\u00f3n de registro limitada y no cr\u00edtica."
}
],
"id": "CVE-2023-4292",
"lastModified": "2026-06-17T06:37:29.343",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-4292",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-24T18:18:17.024082Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-09-21T07:15:19.817",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-038"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-038"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-4291
Vulnerability from fkie_nvd - Published: 2023-09-21 07:15 - Updated: 2026-06-17 06:37
Severity
Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication. This could lead to a full compromise of the FDS101 device.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-038 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-038 | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| frauscher | frauscher_diagnostic_system_101 | * | |
| frauscher | frauscher_diagnostic_system_101 | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "FDS101 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadc:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadci:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:*:*:*:*:*:fadc:*:*",
"matchCriteriaId": "8C27C13A-FDC8-4E2C-A4E0-324A29040DC5",
"versionEndIncluding": "1.4.24",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:*:*:*:*:*:fadci:*:*",
"matchCriteriaId": "65E1CCBA-51DB-439D-951F-1EC97EB9E58D",
"versionEndIncluding": "1.4.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication.\u00a0This could lead to a full compromise of the FDS101 device.\n\n\n"
},
{
"lang": "es",
"value": "Frauscher Sensortechnik GmbH FDS101 para FAdC/FAdCi v1.4.24 y todas las versiones anteriores son vulnerables a una vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo (RCE) a trav\u00e9s de par\u00e1metros manipulados de la interfaz web sin autenticaci\u00f3n. Esto podr\u00eda provocar un compromiso total del dispositivo FDS101."
}
],
"id": "CVE-2023-4291",
"lastModified": "2026-06-17T06:37:29.217",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-4291",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-24T15:45:35.351295Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-09-21T07:15:18.423",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-038"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-038"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-94"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-4152
Vulnerability from fkie_nvd - Published: 2023-09-21 07:15 - Updated: 2026-06-17 06:37
Severity
Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-038/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-038/ | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| frauscher | frauscher_diagnostic_system_101 | * | |
| frauscher | frauscher_diagnostic_system_101 | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "FDS101 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadc:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadci:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:*:*:*:*:*:fadc:*:*",
"matchCriteriaId": "8C27C13A-FDC8-4E2C-A4E0-324A29040DC5",
"versionEndIncluding": "1.4.24",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:*:*:*:*:*:fadci:*:*",
"matchCriteriaId": "65E1CCBA-51DB-439D-951F-1EC97EB9E58D",
"versionEndIncluding": "1.4.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.\n"
},
{
"lang": "es",
"value": "Frauscher Sensortechnik GmbH FDS101 para FAdC/FAdCi v1.4.24 y todas las versiones anteriores son vulnerables a una vulnerabilidad de Path Traversal de la interfaz web mediante una URL manipulada sin autenticaci\u00f3n. Esto permite a un atacante remoto leer todos los archivos en el sistema de archivos del dispositivo FDS101."
}
],
"id": "CVE-2023-4152",
"lastModified": "2026-06-17T06:37:11.357",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-4152",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-24T16:19:46.131129Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-09-21T07:15:14.300",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-038/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-038/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-2880
Vulnerability from fkie_nvd - Published: 2023-07-05 10:15 - Updated: 2026-06-17 05:53
Severity
Summary
Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-011/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-011/ | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| frauscher | frauscher_diagnostic_system_101 | * | |
| frauscher | frauscher_diagnostic_system_101 | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Diagnostic System FDS101 for FAdC/FAdCi",
"vendor": "Frauscher Sensortechnik",
"versions": [
{
"lessThanOrEqual": "1.3.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:*:*:*:*:*:fadc:*:*",
"matchCriteriaId": "427140E6-3417-4EA0-8637-0E3611ADE517",
"versionEndIncluding": "1.3.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:*:*:*:*:*:fadci:*:*",
"matchCriteriaId": "EFF336E0-CE6E-4502-9450-EC4FAA4F6573",
"versionEndIncluding": "1.3.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device."
}
],
"id": "CVE-2023-2880",
"lastModified": "2026-06-17T05:53:41.507",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-2880",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-20T21:26:00.294473Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-07-05T10:15:09.567",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-011/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-011/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-3575
Vulnerability from fkie_nvd - Published: 2022-11-02 17:15 - Updated: 2026-06-17 04:59
Severity
Summary
Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://www.frauscher.com/en/psirt | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.frauscher.com/en/psirt | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| frauscher | frauscher_diagnostic_system_102 | 2.8.0 | |
| frauscher | frauscher_diagnostic_system_102 | 2.8.0 | |
| frauscher | frauscher_diagnostic_system_102 | 2.9.0 | |
| frauscher | frauscher_diagnostic_system_102 | 2.9.0 | |
| frauscher | frauscher_diagnostic_system_102 | 2.9.1 | |
| frauscher | frauscher_diagnostic_system_102 | 2.9.1 |
{
"affected": [
{
"affectedData": [
{
"product": "Diagnostic System FDS102",
"vendor": "Frauscher Sensortechnik",
"versions": [
{
"lessThanOrEqual": "v2.9.1",
"status": "affected",
"version": "v2.8.0",
"versionType": "custom"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_102:2.8.0:*:*:*:*:fadc_r2:*:*",
"matchCriteriaId": "F46EB758-1260-40FB-A5D5-87C11CA5964B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_102:2.8.0:*:*:*:*:fadci_r2:*:*",
"matchCriteriaId": "ADB27623-E59D-4062-90AB-7787624971B2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_102:2.9.0:*:*:*:*:fadc_r2:*:*",
"matchCriteriaId": "A66B5545-5CF4-4CD2-93BA-D77D5A889DD6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_102:2.9.0:*:*:*:*:fadci_r2:*:*",
"matchCriteriaId": "FC2D7FAF-C89C-49DC-B85A-BD36E4B7B9A6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_102:2.9.1:*:*:*:*:fadc_r2:*:*",
"matchCriteriaId": "27810BDA-FED1-48CD-B3D8-6B60C0B9195C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_102:2.9.1:*:*:*:*:fadci_r2:*:*",
"matchCriteriaId": "F32CAEB4-0CCD-463D-AAFE-88AD4FF6D3EB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device."
},
{
"lang": "es",
"value": "Frauscher Sensortechnik GmbH FDS102 para FAdC R2 y FAdCi R2 v2.8.0 a v2.9.1 son vulnerables a la carga de c\u00f3digos maliciosos sin autenticaci\u00f3n mediante la funci\u00f3n de carga de configuraci\u00f3n. Esto podr\u00eda provocar un compromiso total del dispositivo FDS102."
}
],
"id": "CVE-2022-3575",
"lastModified": "2026-06-17T04:59:46.530",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-3575",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-05T13:43:41.724498Z",
"version": "2.0.3"
}
}
]
},
"published": "2022-11-02T17:15:18.673",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.frauscher.com/en/psirt"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.frauscher.com/en/psirt"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-434"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
CVE-2025-3705 (GCVE-0-2025-3705)
Vulnerability from nvd – Published: 2025-07-07 09:20 – Updated: 2025-07-07 17:34
VLAI
EPSS
VEX
Title
OS Command Injection via USB Config Load
Summary
A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command ('OS Command Injection') when loading a config file from a USB drive.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-07 17:33 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3705",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-07T17:33:44.109898Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-07T17:34:15.583Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS102",
"vendor": "Frauscher",
"versions": [
{
"lessThan": "v2.13.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FDS101",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "v1.4.25",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FDS-SNMP101",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "v.2.3.9",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive."
}
],
"value": "A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-07T09:20:03.263Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-030"
}
],
"source": {
"advisory": "VDE-2025-030",
"defect": [
"CERT@VDE#641766"
],
"discovery": "UNKNOWN"
},
"title": "OS Command Injection via USB Config Load",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-3705",
"datePublished": "2025-07-07T09:20:03.263Z",
"dateReserved": "2025-04-16T06:43:57.178Z",
"dateUpdated": "2025-07-07T17:34:15.583Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3626 (GCVE-0-2025-3626)
Vulnerability from nvd – Published: 2025-07-07 09:19 – Updated: 2025-07-07 17:37
VLAI
EPSS
VEX
Title
OS Command Injection via Config Upload in WebUI
Summary
A remote attacker with administrator account can gain full control of the device due to improper neutralization of special elements used in an OS Command ('OS Command Injection') while uploading a config file via webUI.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-07 17:35 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3626",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-07T17:35:09.422716Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-07T17:37:17.846Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS102",
"vendor": "Frauscher",
"versions": [
{
"lessThan": "v2.13.3",
"status": "affected",
"version": "v2.8.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A remote attacker with administrator account can gain full control of the device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) while uploading a config file via webUI.\u003cbr\u003e"
}
],
"value": "A remote attacker with administrator account can gain full control of the device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) while uploading a config file via webUI."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-07T09:19:21.718Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-030"
}
],
"source": {
"advisory": "VDE-2025-030",
"defect": [
"CERT@VDE#641766"
],
"discovery": "UNKNOWN"
},
"title": "OS Command Injection via Config Upload in WebUI",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-3626",
"datePublished": "2025-07-07T09:19:21.718Z",
"dateReserved": "2025-04-15T07:11:08.129Z",
"dateUpdated": "2025-07-07T17:37:17.846Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5500 (GCVE-0-2023-5500)
Vulnerability from nvd – Published: 2023-12-11 07:13 – Updated: 2024-08-02 07:59
VLAI
EPSS
VEX
Title
Frauscher: FDS102 for FAdC/FAdCi remote code execution vulnerability
Summary
This vulnerability allows an remote attacker with low privileges to misuse Improper Control of Generation of Code ('Code Injection') to gain full control of the affected device.
Severity
8.8 (High)
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher | FDS102 for FAdC/FAdCi |
Affected:
2.10.0 , ≤ 2.10.1
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.783Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-049/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS102 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "2.10.1",
"status": "affected",
"version": "2.10.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability allows an remote attacker with low privileges to misuse Improper Control of Generation of Code (\u0027Code Injection\u0027) to gain full control of the affected device."
}
],
"value": "This vulnerability allows an remote attacker with low privileges to misuse Improper Control of Generation of Code (\u0027Code Injection\u0027) to gain full control of the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-11T07:13:51.308Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-049/"
}
],
"source": {
"advisory": "VDE-2023-049",
"defect": [
"CERT@VDE#64600"
],
"discovery": "UNKNOWN"
},
"title": "Frauscher: FDS102 for FAdC/FAdCi remote code execution vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-5500",
"datePublished": "2023-12-11T07:13:51.308Z",
"dateReserved": "2023-10-10T13:52:02.969Z",
"dateUpdated": "2024-08-02T07:59:44.783Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4292 (GCVE-0-2023-4292)
Vulnerability from nvd – Published: 2023-09-21 06:18 – Updated: 2024-09-24 18:18
VLAI
EPSS
VEX
Title
Frauscher FDS101 for FAdC/FAdCi SQL injection vulnerability
Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical log information.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-24 18:18 UTC
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher | FDS101 for FAdC/FAdCi |
Affected:
0 , ≤ 1.4.24
(semver)
|
Date Public
2023-09-21 06:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:24:03.692Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-038"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4292",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-24T18:18:17.024082Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-24T18:18:27.494Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS101 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2023-09-21T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eFrauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical log information.\u003cbr\u003e\u003c/div\u003e\u003cbr\u003e"
}
],
"value": "Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical log information.\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-21T06:18:43.430Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-038"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Frauscher FDS101 for FAdC/FAdCi SQL injection vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-4292",
"datePublished": "2023-09-21T06:18:43.430Z",
"dateReserved": "2023-08-10T12:36:11.727Z",
"dateUpdated": "2024-09-24T18:18:27.494Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4291 (GCVE-0-2023-4291)
Vulnerability from nvd – Published: 2023-09-21 06:17 – Updated: 2024-09-24 16:16
VLAI
EPSS
VEX
Title
Frauscher FDS101 for FAdC/FAdCi remote code execution vulnerability
Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication. This could lead to a full compromise of the FDS101 device.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-24 15:45 UTC
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
1 reference
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher | FDS101 for FAdC/FAdCi |
Affected:
0 , ≤ 1.4.24
(semver)
|
|
| frauscher | frauscher_diagnostic_system_101 |
Affected:
0 , ≤ 1.4.24
(custom)
cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadc:*:* |
|
| frauscher | frauscher_diagnostic_system_101 |
Affected:
0 , ≤ 1.4.24
(custom)
cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadci:*:* |
Date Public
2023-09-21 06:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:24:04.644Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-038"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadc:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadci:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4291",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-24T15:45:35.351295Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-24T16:16:55.237Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS101 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2023-09-21T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eFrauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication.\u0026nbsp;\u003cspan style=\"background-color: var(--wht);\"\u003eThis could lead to a full compromise of the FDS101 device.\u003c/span\u003e\u003c/div\u003e\u003cbr\u003e"
}
],
"value": "Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication.\u00a0This could lead to a full compromise of the FDS101 device.\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-21T06:17:57.646Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-038"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Frauscher FDS101 for FAdC/FAdCi remote code execution vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-4291",
"datePublished": "2023-09-21T06:17:57.646Z",
"dateReserved": "2023-08-10T12:30:45.947Z",
"dateUpdated": "2024-09-24T16:16:55.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4152 (GCVE-0-2023-4152)
Vulnerability from nvd – Published: 2023-09-21 06:18 – Updated: 2024-09-24 16:21
VLAI
EPSS
VEX
Title
Frauscher FDS101 for FAdC/FAdCi path traversal vulnerability
Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-24 16:19 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher | FDS101 for FAdC/FAdCi |
Affected:
0 , ≤ 1.4.24
(semver)
|
|
| frauscher | frauscher_diagnostic_system_101 |
Affected:
0 , ≤ 1.4.24
(custom)
cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadc:*:* |
|
| frauscher | frauscher_diagnostic_system_101 |
Affected:
0 , ≤ 1.4.24
(custom)
cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadci:*:* |
Date Public
2023-09-21 06:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:17:11.935Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-038/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadc:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadci:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4152",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-24T16:19:46.131129Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-24T16:21:57.187Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS101 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2023-09-21T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFrauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-21T06:18:21.444Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-038/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Frauscher FDS101 for FAdC/FAdCi path traversal vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-4152",
"datePublished": "2023-09-21T06:18:21.444Z",
"dateReserved": "2023-08-04T09:57:19.862Z",
"dateUpdated": "2024-09-24T16:21:57.187Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-2880 (GCVE-0-2023-2880)
Vulnerability from nvd – Published: 2023-07-05 09:04 – Updated: 2024-11-20 21:26
VLAI
EPSS
VEX
Title
Frauscher Sensortechnik Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability
Summary
Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-20 21:26 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher Sensortechnik | Diagnostic System FDS101 for FAdC/FAdCi |
Affected:
0 , ≤ 1.3.3
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:41:02.358Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-011/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-2880",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-20T21:26:00.294473Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-20T21:26:10.093Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Diagnostic System FDS101 for FAdC/FAdCi",
"vendor": "Frauscher Sensortechnik",
"versions": [
{
"lessThanOrEqual": "1.3.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device."
}
],
"value": "Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-05T09:04:28.091Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-011/"
}
],
"source": {
"advisory": "VDE-2023-011",
"defect": [
"CERT@VDE#64526"
],
"discovery": "INTERNAL"
},
"title": "Frauscher Sensortechnik Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-2880",
"datePublished": "2023-07-05T09:04:28.091Z",
"dateReserved": "2023-05-25T07:17:13.633Z",
"dateUpdated": "2024-11-20T21:26:10.093Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3575 (GCVE-0-2022-3575)
Vulnerability from nvd – Published: 2022-11-02 16:15 – Updated: 2025-05-05 13:43
VLAI
EPSS
VEX
Title
Frauscher Sensortechnik Diagnostic System FDS102 for FAdC R2 and FAdCi R2 configuration upload vulnerability
Summary
Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-05 13:43 UTC
CWE
- CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.frauscher.com/en/psirt |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher Sensortechnik | Diagnostic System FDS102 |
Affected:
v2.8.0 , ≤ v2.9.1
(custom)
|
Date Public
2022-11-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:14:02.455Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.frauscher.com/en/psirt"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3575",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-05T13:43:41.724498Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T13:43:51.404Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Diagnostic System FDS102",
"vendor": "Frauscher Sensortechnik",
"versions": [
{
"lessThanOrEqual": "v2.9.1",
"status": "affected",
"version": "v2.8.0",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-11-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-02T00:00:00.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.frauscher.com/en/psirt"
}
],
"solutions": [
{
"lang": "en",
"value": "Update to v2.9.2 or higher."
}
],
"source": {
"defect": [
"CERT@VDE#64262"
],
"discovery": "INTERNAL"
},
"title": "Frauscher Sensortechnik Diagnostic System FDS102 for FAdC R2 and FAdCi R2 configuration upload vulnerability",
"x_generator": {
"engine": "vulnogram 0.1.0-rc1"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-3575",
"datePublished": "2022-11-02T16:15:33.921Z",
"dateReserved": "2022-10-18T00:00:00.000Z",
"dateUpdated": "2025-05-05T13:43:51.404Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3705 (GCVE-0-2025-3705)
Vulnerability from cvelistv5 – Published: 2025-07-07 09:20 – Updated: 2025-07-07 17:34
VLAI
EPSS
VEX
Title
OS Command Injection via USB Config Load
Summary
A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command ('OS Command Injection') when loading a config file from a USB drive.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-07 17:33 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3705",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-07T17:33:44.109898Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-07T17:34:15.583Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS102",
"vendor": "Frauscher",
"versions": [
{
"lessThan": "v2.13.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FDS101",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "v1.4.25",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FDS-SNMP101",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "v.2.3.9",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive."
}
],
"value": "A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-07T09:20:03.263Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-030"
}
],
"source": {
"advisory": "VDE-2025-030",
"defect": [
"CERT@VDE#641766"
],
"discovery": "UNKNOWN"
},
"title": "OS Command Injection via USB Config Load",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-3705",
"datePublished": "2025-07-07T09:20:03.263Z",
"dateReserved": "2025-04-16T06:43:57.178Z",
"dateUpdated": "2025-07-07T17:34:15.583Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3626 (GCVE-0-2025-3626)
Vulnerability from cvelistv5 – Published: 2025-07-07 09:19 – Updated: 2025-07-07 17:37
VLAI
EPSS
VEX
Title
OS Command Injection via Config Upload in WebUI
Summary
A remote attacker with administrator account can gain full control of the device due to improper neutralization of special elements used in an OS Command ('OS Command Injection') while uploading a config file via webUI.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-07 17:35 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3626",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-07T17:35:09.422716Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-07T17:37:17.846Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS102",
"vendor": "Frauscher",
"versions": [
{
"lessThan": "v2.13.3",
"status": "affected",
"version": "v2.8.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A remote attacker with administrator account can gain full control of the device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) while uploading a config file via webUI.\u003cbr\u003e"
}
],
"value": "A remote attacker with administrator account can gain full control of the device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) while uploading a config file via webUI."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-07T09:19:21.718Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-030"
}
],
"source": {
"advisory": "VDE-2025-030",
"defect": [
"CERT@VDE#641766"
],
"discovery": "UNKNOWN"
},
"title": "OS Command Injection via Config Upload in WebUI",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-3626",
"datePublished": "2025-07-07T09:19:21.718Z",
"dateReserved": "2025-04-15T07:11:08.129Z",
"dateUpdated": "2025-07-07T17:37:17.846Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5500 (GCVE-0-2023-5500)
Vulnerability from cvelistv5 – Published: 2023-12-11 07:13 – Updated: 2024-08-02 07:59
VLAI
EPSS
VEX
Title
Frauscher: FDS102 for FAdC/FAdCi remote code execution vulnerability
Summary
This vulnerability allows an remote attacker with low privileges to misuse Improper Control of Generation of Code ('Code Injection') to gain full control of the affected device.
Severity
8.8 (High)
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher | FDS102 for FAdC/FAdCi |
Affected:
2.10.0 , ≤ 2.10.1
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:59:44.783Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-049/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS102 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "2.10.1",
"status": "affected",
"version": "2.10.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability allows an remote attacker with low privileges to misuse Improper Control of Generation of Code (\u0027Code Injection\u0027) to gain full control of the affected device."
}
],
"value": "This vulnerability allows an remote attacker with low privileges to misuse Improper Control of Generation of Code (\u0027Code Injection\u0027) to gain full control of the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-11T07:13:51.308Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-049/"
}
],
"source": {
"advisory": "VDE-2023-049",
"defect": [
"CERT@VDE#64600"
],
"discovery": "UNKNOWN"
},
"title": "Frauscher: FDS102 for FAdC/FAdCi remote code execution vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-5500",
"datePublished": "2023-12-11T07:13:51.308Z",
"dateReserved": "2023-10-10T13:52:02.969Z",
"dateUpdated": "2024-08-02T07:59:44.783Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4292 (GCVE-0-2023-4292)
Vulnerability from cvelistv5 – Published: 2023-09-21 06:18 – Updated: 2024-09-24 18:18
VLAI
EPSS
VEX
Title
Frauscher FDS101 for FAdC/FAdCi SQL injection vulnerability
Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical log information.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-24 18:18 UTC
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher | FDS101 for FAdC/FAdCi |
Affected:
0 , ≤ 1.4.24
(semver)
|
Date Public
2023-09-21 06:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:24:03.692Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-038"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4292",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-24T18:18:17.024082Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-24T18:18:27.494Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS101 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2023-09-21T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eFrauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical log information.\u003cbr\u003e\u003c/div\u003e\u003cbr\u003e"
}
],
"value": "Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical log information.\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-21T06:18:43.430Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-038"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Frauscher FDS101 for FAdC/FAdCi SQL injection vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-4292",
"datePublished": "2023-09-21T06:18:43.430Z",
"dateReserved": "2023-08-10T12:36:11.727Z",
"dateUpdated": "2024-09-24T18:18:27.494Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4152 (GCVE-0-2023-4152)
Vulnerability from cvelistv5 – Published: 2023-09-21 06:18 – Updated: 2024-09-24 16:21
VLAI
EPSS
VEX
Title
Frauscher FDS101 for FAdC/FAdCi path traversal vulnerability
Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-24 16:19 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher | FDS101 for FAdC/FAdCi |
Affected:
0 , ≤ 1.4.24
(semver)
|
|
| frauscher | frauscher_diagnostic_system_101 |
Affected:
0 , ≤ 1.4.24
(custom)
cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadc:*:* |
|
| frauscher | frauscher_diagnostic_system_101 |
Affected:
0 , ≤ 1.4.24
(custom)
cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadci:*:* |
Date Public
2023-09-21 06:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:17:11.935Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-038/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadc:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadci:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4152",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-24T16:19:46.131129Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-24T16:21:57.187Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS101 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2023-09-21T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFrauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-21T06:18:21.444Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-038/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Frauscher FDS101 for FAdC/FAdCi path traversal vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-4152",
"datePublished": "2023-09-21T06:18:21.444Z",
"dateReserved": "2023-08-04T09:57:19.862Z",
"dateUpdated": "2024-09-24T16:21:57.187Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-4291 (GCVE-0-2023-4291)
Vulnerability from cvelistv5 – Published: 2023-09-21 06:17 – Updated: 2024-09-24 16:16
VLAI
EPSS
VEX
Title
Frauscher FDS101 for FAdC/FAdCi remote code execution vulnerability
Summary
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication. This could lead to a full compromise of the FDS101 device.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-24 15:45 UTC
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
1 reference
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher | FDS101 for FAdC/FAdCi |
Affected:
0 , ≤ 1.4.24
(semver)
|
|
| frauscher | frauscher_diagnostic_system_101 |
Affected:
0 , ≤ 1.4.24
(custom)
cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadc:*:* |
|
| frauscher | frauscher_diagnostic_system_101 |
Affected:
0 , ≤ 1.4.24
(custom)
cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadci:*:* |
Date Public
2023-09-21 06:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:24:04.644Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-038"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadc:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:-:*:*:*:*:fadci:*:*"
],
"defaultStatus": "unknown",
"product": "frauscher_diagnostic_system_101",
"vendor": "frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4291",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-24T15:45:35.351295Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-24T16:16:55.237Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS101 for FAdC/FAdCi",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "1.4.24",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2023-09-21T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eFrauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication.\u0026nbsp;\u003cspan style=\"background-color: var(--wht);\"\u003eThis could lead to a full compromise of the FDS101 device.\u003c/span\u003e\u003c/div\u003e\u003cbr\u003e"
}
],
"value": "Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication.\u00a0This could lead to a full compromise of the FDS101 device.\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-21T06:17:57.646Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-038"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Frauscher FDS101 for FAdC/FAdCi remote code execution vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-4291",
"datePublished": "2023-09-21T06:17:57.646Z",
"dateReserved": "2023-08-10T12:30:45.947Z",
"dateUpdated": "2024-09-24T16:16:55.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-2880 (GCVE-0-2023-2880)
Vulnerability from cvelistv5 – Published: 2023-07-05 09:04 – Updated: 2024-11-20 21:26
VLAI
EPSS
VEX
Title
Frauscher Sensortechnik Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability
Summary
Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-20 21:26 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher Sensortechnik | Diagnostic System FDS101 for FAdC/FAdCi |
Affected:
0 , ≤ 1.3.3
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:41:02.358Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-011/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-2880",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-20T21:26:00.294473Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-20T21:26:10.093Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Diagnostic System FDS101 for FAdC/FAdCi",
"vendor": "Frauscher Sensortechnik",
"versions": [
{
"lessThanOrEqual": "1.3.3",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device."
}
],
"value": "Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-05T09:04:28.091Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-011/"
}
],
"source": {
"advisory": "VDE-2023-011",
"defect": [
"CERT@VDE#64526"
],
"discovery": "INTERNAL"
},
"title": "Frauscher Sensortechnik Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-2880",
"datePublished": "2023-07-05T09:04:28.091Z",
"dateReserved": "2023-05-25T07:17:13.633Z",
"dateUpdated": "2024-11-20T21:26:10.093Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3575 (GCVE-0-2022-3575)
Vulnerability from cvelistv5 – Published: 2022-11-02 16:15 – Updated: 2025-05-05 13:43
VLAI
EPSS
VEX
Title
Frauscher Sensortechnik Diagnostic System FDS102 for FAdC R2 and FAdCi R2 configuration upload vulnerability
Summary
Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-05 13:43 UTC
CWE
- CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.frauscher.com/en/psirt |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Frauscher Sensortechnik | Diagnostic System FDS102 |
Affected:
v2.8.0 , ≤ v2.9.1
(custom)
|
Date Public
2022-11-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:14:02.455Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.frauscher.com/en/psirt"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3575",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-05T13:43:41.724498Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T13:43:51.404Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Diagnostic System FDS102",
"vendor": "Frauscher Sensortechnik",
"versions": [
{
"lessThanOrEqual": "v2.9.1",
"status": "affected",
"version": "v2.8.0",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-11-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-02T00:00:00.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.frauscher.com/en/psirt"
}
],
"solutions": [
{
"lang": "en",
"value": "Update to v2.9.2 or higher."
}
],
"source": {
"defect": [
"CERT@VDE#64262"
],
"discovery": "INTERNAL"
},
"title": "Frauscher Sensortechnik Diagnostic System FDS102 for FAdC R2 and FAdCi R2 configuration upload vulnerability",
"x_generator": {
"engine": "vulnogram 0.1.0-rc1"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-3575",
"datePublished": "2022-11-02T16:15:33.921Z",
"dateReserved": "2022-10-18T00:00:00.000Z",
"dateUpdated": "2025-05-05T13:43:51.404Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}