Search

Find a vulnerability

Search criteria

    118 vulnerabilities by Johnson Controls

    CVE-2025-43874 (GCVE-0-2025-43874)

    Vulnerability from cvelistv5 – Published: 2026-11-13 21:59 – Updated: 2026-11-13 21:59
    VLAI
    Summary
    : Improper Neutralization of Special Elements used in an OS Command vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows : OS Command Injection. This issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls iSTAR Ultra Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra SE Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra G2 Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra G2 SE Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Edge G2 Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR  Ultra",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra SE",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra G2",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra G2 SE",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Edge G2",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": ": Improper Neutralization of Special Elements used in an OS Command vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows : OS Command Injection.\u003cp\u003eThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.\u003c/p\u003e"
                }
              ],
              "value": ": Improper Neutralization of Special Elements used in an OS Command vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows : OS Command Injection.\n\nThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88: OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-13T21:59:57.409Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2025-43874",
        "datePublished": "2026-11-13T21:59:57.409Z",
        "dateReserved": "2025-04-17T20:07:25.122Z",
        "dateUpdated": "2026-11-13T21:59:57.409Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-53700 (GCVE-0-2025-53700)

    Vulnerability from cvelistv5 – Published: 2026-11-13 21:56 – Updated: 2026-11-13 21:56
    VLAI
    Summary
    CWE‑922 Insecure Storage of Sensitive Information vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC‑15 File Manipulation. This issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.
    CWE
    • CWE‑922 Insecure Storage of Sensitive Information
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls iSTAR Ultra Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra SE Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra G2 Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra G2 SE Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Edge G2 Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra SE",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra G2",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra G2 SE",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Edge G2",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CWE\u2011922 Insecure Storage of Sensitive Information vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC\u201115 File Manipulation.\u003cp\u003eThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.\u003c/p\u003e"
                }
              ],
              "value": "CWE\u2011922 Insecure Storage of Sensitive Information vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC\u201115 File Manipulation.\n\nThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC\u201115 File Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE\u2011922 Insecure Storage of Sensitive Information",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-13T21:56:12.492Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2025-53700",
        "datePublished": "2026-11-13T21:56:12.492Z",
        "dateReserved": "2025-07-08T14:48:42.604Z",
        "dateUpdated": "2026-11-13T21:56:12.492Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-53699 (GCVE-0-2025-53699)

    Vulnerability from cvelistv5 – Published: 2026-11-13 21:50 – Updated: 2026-11-13 21:50
    VLAI
    Summary
    Missing protection mechanism for alternate hardware interface vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC‑554: Functionality Bypass. This issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.
    CWE
    • CWE-1299 - Missing protection mechanism for alternate hardware interface
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls iSTAR Ultra Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra SE Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra G2 Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra G2 SE Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Edge G2 Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra SE",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra G2",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra G2 SE",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Edge G2",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing protection mechanism for alternate hardware interface vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC\u2011554: Functionality Bypass.\u003cp\u003eThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.\u003c/p\u003e"
                }
              ],
              "value": "Missing protection mechanism for alternate hardware interface vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC\u2011554: Functionality Bypass.\n\nThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC\u2011554: Functionality Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "PHYSICAL",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1299",
                  "description": "CWE-1299 Missing protection mechanism for alternate hardware interface",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-13T21:50:56.925Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2025-53699",
        "datePublished": "2026-11-13T21:50:56.925Z",
        "dateReserved": "2025-07-08T14:48:42.604Z",
        "dateUpdated": "2026-11-13T21:50:56.925Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-53698 (GCVE-0-2025-53698)

    Vulnerability from cvelistv5 – Published: 2026-11-13 21:46 – Updated: 2026-11-13 21:46
    VLAI
    Summary
    Missing protection mechanism for alternate hardware interface vulnerability in Johnson Controls iSTAR Ultra and Johnson Controls iSTAR Ultra SE allows CAPEC‑554: Functionality Bypass. This issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02.
    CWE
    • CWE-1299 - Missing protection mechanism for alternate hardware interface
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls iSTAR Ultra Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra SE Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra SE",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing protection mechanism for alternate hardware interface vulnerability in Johnson Controls iSTAR Ultra and Johnson Controls iSTAR Ultra SE allows CAPEC\u2011554: Functionality Bypass.\u003cp\u003eThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02.\u003c/p\u003e"
                }
              ],
              "value": "Missing protection mechanism for alternate hardware interface vulnerability in Johnson Controls iSTAR Ultra and Johnson Controls iSTAR Ultra SE allows CAPEC\u2011554: Functionality Bypass.\n\nThis issue affects iSTAR Ultra: before 6.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC\u2011554: Functionality Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "PHYSICAL",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1299",
                  "description": "CWE-1299 Missing protection mechanism for alternate hardware interface",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-13T21:46:48.829Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2025-53698",
        "datePublished": "2026-11-13T21:46:48.829Z",
        "dateReserved": "2025-07-08T14:48:42.604Z",
        "dateUpdated": "2026-11-13T21:46:48.829Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-53697 (GCVE-0-2025-53697)

    Vulnerability from cvelistv5 – Published: 2026-11-13 21:37 – Updated: 2026-11-13 21:41
    VLAI
    Summary
    Use of default credentials vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC‑560: Use of Default Credentials. This issue affects iSTAR Ultra: before 2.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.
    CWE
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls iSTAR Ultra Affected: 0 , < 2.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra SE Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra G2 Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Ultra G2 SE Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls iSTAR Edge G2 Affected: 0 , < 6.9.2.CU02 (custom)
        cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "2.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra SE",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra G2",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Ultra G2 SE",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iSTAR Edge G2",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.9.2.CU02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_se:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_ultra_g2_se:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:istar_edge_g2:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "6.9.2.cu02",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of default credentials vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC\u2011560: Use of Default Credentials.\u003cp\u003eThis issue affects iSTAR Ultra: before 2.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.\u003c/p\u003e"
                }
              ],
              "value": "Use of default credentials vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC\u2011560: Use of Default Credentials.\n\nThis issue affects iSTAR Ultra: before 2.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC\u2011560: Use of Default Credentials"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1392",
                  "description": "CWE-1392 Use of default credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-13T21:41:47.141Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2025-53697",
        "datePublished": "2026-11-13T21:37:44.321Z",
        "dateReserved": "2025-07-08T14:48:42.604Z",
        "dateUpdated": "2026-11-13T21:41:47.141Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-43867 (GCVE-0-2025-43867)

    Vulnerability from cvelistv5 – Published: 2026-11-13 20:14 – Updated: 2026-11-13 21:27
    VLAI
    Summary
    - Dependency on Vulnerable Third-Party Component vulnerability in Johnson Controls FX Server, Johnson Controls FX80, and Johnson Controls FX90 allows CAPEC‑17: Accessing, Modifying or Deleting Files. This issue affects FX Server: before 14.10.10 and before 14.14.1; FX80: before 14.14.10 and before 14.14.1; FX90: before 14.10.10 and before 14.14.1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-13 21:23 UTC
    CWE
    • CWE-1395 - - Dependency on Vulnerable Third-Party Component
    • CWE-1395 - Dependency on Vulnerable Third-Party Component
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls FX Server Affected: 0 , < 14.10.10 (custom)
    Affected: 0 , < 14.14.1 (custom)
    Create a notification for this product.
    Johnson Controls FX80 Affected: 0 , < 14.14.10 (custom)
    Affected: 0 , < 14.14.1 (custom)
    Create a notification for this product.
    Johnson Controls FX90 Affected: 0 , < 14.10.10 (custom)
    Affected: 0 , < 14.14.1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-43867",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-13T21:23:26.021386Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-1395",
                    "description": "CWE-1395 Dependency on Vulnerable Third-Party Component",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-13T21:27:33.159Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FX Server",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "14.10.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "14.14.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "FX80",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "14.14.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "14.14.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "FX90",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "14.10.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "14.14.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "- Dependency on Vulnerable Third-Party Component vulnerability in Johnson Controls FX Server, Johnson Controls FX80, and Johnson Controls FX90 allows CAPEC\u201117: Accessing, Modifying or Deleting Files.\u003cp\u003eThis issue affects FX Server: before 14.10.10 and before 14.14.1; FX80: before 14.14.10 and before 14.14.1; FX90: before 14.10.10 and before 14.14.1.\u003c/p\u003e"
                }
              ],
              "value": "- Dependency on Vulnerable Third-Party Component vulnerability in Johnson Controls FX Server, Johnson Controls FX80, and Johnson Controls FX90 allows CAPEC\u201117: Accessing, Modifying or Deleting Files.\n\nThis issue affects FX Server: before 14.10.10 and before 14.14.1; FX80: before 14.14.10 and before 14.14.1; FX90: before 14.10.10 and before 14.14.1."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC\u201117: Accessing, Modifying or Deleting Files"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1395",
                  "description": "CWE-1395 - Dependency on Vulnerable Third-Party Component",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-13T20:14:16.172Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2025-43867",
        "datePublished": "2026-11-13T20:14:16.172Z",
        "dateReserved": "2025-04-17T20:07:25.121Z",
        "dateUpdated": "2026-11-13T21:27:33.159Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-106018 (GCVE-0-2026-106018)

    Vulnerability from cvelistv5 – Published: 2026-11-12 20:50 – Updated: 2026-11-13 21:32
    VLAI
    Summary
    Authentication bypass using an alternate path or channel vulnerability in Johnson Controls EasyIO FW allows Authentication Bypass. This issue affects EasyIO FW: through 3.0b25.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-13 21:32 UTC
    CWE
    • CWE-288 - Authentication bypass using an alternate path or channel
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls EasyIO FW Affected: 0 , ≤ 3.0b25 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-106018",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-13T21:32:44.371811Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-13T21:32:54.410Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO FW",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThanOrEqual": "3.0b25",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authentication bypass using an alternate path or channel vulnerability in Johnson Controls EasyIO FW allows Authentication Bypass.\u003cp\u003eThis issue affects EasyIO FW: through 3.0b25.\u003c/p\u003e"
                }
              ],
              "value": "Authentication bypass using an alternate path or channel vulnerability in Johnson Controls EasyIO FW allows Authentication Bypass.\n\nThis issue affects EasyIO FW: through 3.0b25."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-288",
                  "description": "CWE-288 Authentication bypass using an alternate path or channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-12T20:50:42.994Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-106018",
        "datePublished": "2026-11-12T20:50:42.994Z",
        "dateReserved": "2026-10-06T12:44:52.563Z",
        "dateUpdated": "2026-11-13T21:32:54.410Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-106019 (GCVE-0-2026-106019)

    Vulnerability from cvelistv5 – Published: 2026-11-06 14:21 – Updated: 2026-11-11 02:57
    VLAI
    Summary
    Insertion of sensitive information into log file vulnerability in Johnson Controls C-CURE 9000, Victor allows Use of Known Operating System Credentials. This issue affects C-CURE 9000, Victor: 3.20.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-11 02:57 UTC
    CWE
    • CWE-532 - Insertion of sensitive information into log file
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-106019",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-11T02:57:38.441044Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-11T02:57:47.750Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "C-CURE 9000, Victor",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.20"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Insertion of sensitive information into log file vulnerability in Johnson Controls C-CURE 9000, Victor allows Use of Known Operating System Credentials.\u003cp\u003eThis issue affects C-CURE 9000, Victor: 3.20.\u003c/p\u003e"
                }
              ],
              "value": "Insertion of sensitive information into log file vulnerability in Johnson Controls C-CURE 9000, Victor allows Use of Known Operating System Credentials.\n\nThis issue affects C-CURE 9000, Victor: 3.20."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-653",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-653 Use of Known Operating System Credentials"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-532",
                  "description": "CWE-532 Insertion of sensitive information into log file",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-06T14:21:36.622Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-106019",
        "datePublished": "2026-11-06T14:21:36.622Z",
        "dateReserved": "2026-10-06T12:44:52.563Z",
        "dateUpdated": "2026-11-11T02:57:47.750Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-64894 (GCVE-0-2026-64894)

    Vulnerability from cvelistv5 – Published: 2026-11-06 14:12 – Updated: 2026-11-11 02:57
    VLAI
    Summary
    Inclusion of functionality from untrusted control sphere vulnerability in Johnson Controls EasyIO Neo IOManager and Tools Installer allows Malicious Software Update. This issue affects EasyIO Neo IOManager and Tools Installer: 1.1.0.0.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-11 02:55 UTC
    CWE
    • CWE-829 - Inclusion of functionality from untrusted control sphere
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-64894",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-11T02:55:24.206169Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-11T02:57:03.693Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO Neo IOManager and Tools Installer",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1.0.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Inclusion of functionality from untrusted control sphere vulnerability in Johnson Controls EasyIO Neo IOManager and Tools Installer allows Malicious Software Update.\u003cp\u003eThis issue affects EasyIO Neo IOManager and Tools Installer: 1.1.0.0.\u003c/p\u003e"
                }
              ],
              "value": "Inclusion of functionality from untrusted control sphere vulnerability in Johnson Controls EasyIO Neo IOManager and Tools Installer allows Malicious Software Update.\n\nThis issue affects EasyIO Neo IOManager and Tools Installer: 1.1.0.0."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-186",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-186 Malicious Software Update"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "PHYSICAL",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:P/AC:H/AT:P/PR:L/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-829",
                  "description": "CWE-829 Inclusion of functionality from untrusted control sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-06T14:12:23.537Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-64894",
        "datePublished": "2026-11-06T14:12:23.537Z",
        "dateReserved": "2026-07-20T19:51:19.089Z",
        "dateUpdated": "2026-11-11T02:57:03.693Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-106022 (GCVE-0-2026-106022)

    Vulnerability from cvelistv5 – Published: 2026-11-06 14:08 – Updated: 2026-11-10 04:55
    VLAI
    Summary
    Cleartext storage of sensitive information in memory vulnerability in Johnson Controls EasyIO Neo IOManager and Tools Installer allows Retrieve Embedded Sensitive Data. This issue affects EasyIO Neo IOManager and Tools Installer: 1.1.0.0.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-10 04:55 UTC
    CWE
    • CWE-316 - Cleartext storage of sensitive information in memory
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-106022",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-10T04:55:12.827302Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-10T04:55:23.823Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO Neo IOManager and Tools Installer",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1.0.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Cleartext storage of sensitive information in memory vulnerability in Johnson Controls EasyIO Neo IOManager and Tools Installer allows Retrieve Embedded Sensitive Data.\u003cp\u003eThis issue affects EasyIO Neo IOManager and Tools Installer: 1.1.0.0.\u003c/p\u003e"
                }
              ],
              "value": "Cleartext storage of sensitive information in memory vulnerability in Johnson Controls EasyIO Neo IOManager and Tools Installer allows Retrieve Embedded Sensitive Data.\n\nThis issue affects EasyIO Neo IOManager and Tools Installer: 1.1.0.0."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-37",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-316",
                  "description": "CWE-316 Cleartext storage of sensitive information in memory",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-06T14:08:08.053Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-106022",
        "datePublished": "2026-11-06T14:08:08.053Z",
        "dateReserved": "2026-10-06T12:44:52.564Z",
        "dateUpdated": "2026-11-10T04:55:23.823Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-106020 (GCVE-0-2026-106020)

    Vulnerability from cvelistv5 – Published: 2026-11-06 14:04 – Updated: 2026-11-10 04:54
    VLAI
    Summary
    Improper neutralization of input used for LLM prompting vulnerability in Johnson Controls EasyIO Neo IO Manager and Tools Installer allows Search Order Hijacking. This issue affects EasyIO Neo IO Manager and Tools Installer: 1.1.0.0.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-10 04:54 UTC
    CWE
    • CWE-1427 - Improper neutralization of input used for LLM prompting
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-106020",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-10T04:54:11.530447Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-10T04:54:25.467Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO Neo IO Manager and Tools Installer",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1.0.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper neutralization of input used for LLM prompting vulnerability in Johnson Controls EasyIO Neo IO Manager and Tools Installer allows Search Order Hijacking.\u003cp\u003eThis issue affects EasyIO Neo IO Manager and Tools Installer: 1.1.0.0.\u003c/p\u003e"
                }
              ],
              "value": "Improper neutralization of input used for LLM prompting vulnerability in Johnson Controls EasyIO Neo IO Manager and Tools Installer allows Search Order Hijacking.\n\nThis issue affects EasyIO Neo IO Manager and Tools Installer: 1.1.0.0."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-471",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-471 Search Order Hijacking"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1427",
                  "description": "CWE-1427 Improper neutralization of input used for LLM prompting",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-06T14:04:25.674Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-106020",
        "datePublished": "2026-11-06T14:04:25.674Z",
        "dateReserved": "2026-10-06T12:44:52.563Z",
        "dateUpdated": "2026-11-10T04:54:25.467Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-71450 (GCVE-0-2026-71450)

    Vulnerability from cvelistv5 – Published: 2026-11-02 22:49 – Updated: 2026-11-06 17:51
    VLAI
    Summary
    Authentication bypass using an alternate path or channel vulnerability in Johnson Controls EasyIO Neo EC and CW Edge Controller allows Authentication Bypass. This issue affects EasyIO Neo EC and CW Edge Controller: from EC 3.3b62 through EC 3.3b63 and from CW 3.3b24 through CW 3.3b25.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-06 17:51 UTC
    CWE
    • CWE-288 - Authentication bypass using an alternate path or channel
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls EasyIO Neo EC and CW Edge Controller Affected: EC 3.3b62 , ≤ EC 3.3b63 (custom)
    Affected: CW 3.3b24 , ≤ CW 3.3b25 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-71450",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-06T17:51:33.167192Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-06T17:51:42.649Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO Neo EC and CW Edge Controller",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThanOrEqual": "EC 3.3b63",
                  "status": "affected",
                  "version": "EC 3.3b62",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "CW 3.3b25",
                  "status": "affected",
                  "version": "CW 3.3b24",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authentication bypass using an alternate path or channel vulnerability in Johnson Controls EasyIO Neo EC and CW Edge Controller allows Authentication Bypass.\u003cp\u003eThis issue affects EasyIO Neo EC and CW Edge Controller: from EC 3.3b62 through EC 3.3b63 and from CW 3.3b24 through CW 3.3b25.\u003c/p\u003e"
                }
              ],
              "value": "Authentication bypass using an alternate path or channel vulnerability in Johnson Controls EasyIO Neo EC and CW Edge Controller allows Authentication Bypass.\n\nThis issue affects EasyIO Neo EC and CW Edge Controller: from EC 3.3b62 through EC 3.3b63 and from CW 3.3b24 through CW 3.3b25."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-288",
                  "description": "CWE-288 Authentication bypass using an alternate path or channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-02T22:49:00.217Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-71450",
        "datePublished": "2026-11-02T22:49:00.217Z",
        "dateReserved": "2026-08-06T19:11:09.315Z",
        "dateUpdated": "2026-11-06T17:51:42.649Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-71456 (GCVE-0-2026-71456)

    Vulnerability from cvelistv5 – Published: 2026-10-26 16:20 – Updated: 2026-11-02 19:43
    VLAI
    Summary
    Use of hard-coded cryptographic key vulnerability in Johnson Controls Kantech Entrapass allows Padding Oracle Crypto Attack. This issue affects Kantech Entrapass: before 9.20.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-02 18:26 UTC
    CWE
    • CWE-321 - Use of hard-coded cryptographic key
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls Kantech Entrapass Affected: 0 , < 9.20 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-71456",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-02T18:26:52.313012Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-02T19:43:05.947Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Kantech Entrapass",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "9.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of hard-coded cryptographic key vulnerability in Johnson Controls Kantech Entrapass allows Padding Oracle Crypto Attack.\u003cp\u003eThis issue affects Kantech Entrapass: before 9.20.\u003c/p\u003e"
                }
              ],
              "value": "Use of hard-coded cryptographic key vulnerability in Johnson Controls Kantech Entrapass allows Padding Oracle Crypto Attack.\n\nThis issue affects Kantech Entrapass: before 9.20."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-463",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-463 Padding Oracle Crypto Attack"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321 Use of hard-coded cryptographic key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-26T16:20:31.605Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-71456",
        "datePublished": "2026-10-26T16:20:31.605Z",
        "dateReserved": "2026-08-06T19:11:09.315Z",
        "dateUpdated": "2026-11-02T19:43:05.947Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-71455 (GCVE-0-2026-71455)

    Vulnerability from cvelistv5 – Published: 2026-10-26 16:17 – Updated: 2026-11-02 19:43
    VLAI
    Summary
    Cleartext storage of sensitive information in memory vulnerability in Johnson Controls Kantech Entrapass allows Retrieve Embedded Sensitive Data. This issue affects Kantech Entrapass: before 9.20.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-02 18:27 UTC
    CWE
    • CWE-316 - Cleartext storage of sensitive information in memory
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls Kantech Entrapass Affected: 0 , < 9.20 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-71455",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-02T18:27:22.179625Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-02T19:43:06.089Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Kantech Entrapass",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "9.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Cleartext storage of sensitive information in memory vulnerability in Johnson Controls Kantech Entrapass allows Retrieve Embedded Sensitive Data.\u003cp\u003eThis issue affects Kantech Entrapass: before 9.20.\u003c/p\u003e"
                }
              ],
              "value": "Cleartext storage of sensitive information in memory vulnerability in Johnson Controls Kantech Entrapass allows Retrieve Embedded Sensitive Data.\n\nThis issue affects Kantech Entrapass: before 9.20."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-37",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:A/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-316",
                  "description": "CWE-316 Cleartext storage of sensitive information in memory",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-26T16:17:47.898Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-71455",
        "datePublished": "2026-10-26T16:17:47.898Z",
        "dateReserved": "2026-08-06T19:11:09.315Z",
        "dateUpdated": "2026-11-02T19:43:06.089Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-34499 (GCVE-0-2026-34499)

    Vulnerability from cvelistv5 – Published: 2026-10-07 19:36 – Updated: 2026-10-07 20:37
    VLAI
    Summary
    Use of hard-coded cryptographic key vulnerability in Johnson Controls ADVMS allows Read Sensitive Constants Within an Executable. This issue affects ADVMS: before 3.10.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-07 20:37 UTC
    CWE
    • CWE-321 - Use of hard-coded cryptographic key
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls ADVMS Affected: 0 , < 3.10 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-34499",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-07T20:37:24.722182Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-07T20:37:35.137Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ADVMS",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "3.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of hard-coded cryptographic key vulnerability in Johnson Controls ADVMS allows Read Sensitive Constants Within an Executable.\u003cp\u003eThis issue affects ADVMS: before 3.10.\u003c/p\u003e"
                }
              ],
              "value": "Use of hard-coded cryptographic key vulnerability in Johnson Controls ADVMS allows Read Sensitive Constants Within an Executable.\n\nThis issue affects ADVMS: before 3.10."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-191",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-191 Read Sensitive Constants Within an Executable"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321 Use of hard-coded cryptographic key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-07T19:36:37.615Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-34499",
        "datePublished": "2026-10-07T19:36:37.615Z",
        "dateReserved": "2026-03-30T08:25:11.763Z",
        "dateUpdated": "2026-10-07T20:37:35.137Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-34498 (GCVE-0-2026-34498)

    Vulnerability from cvelistv5 – Published: 2026-10-06 13:52 – Updated: 2026-10-06 19:30
    VLAI
    Title
    L4L
    Summary
    Improper input validation vulnerability in Johnson Controls Illustra Standard - L4L China on Windows allows OS Command Injection. This issue affects Illustra Standard - L4L China: before 6.0.0.66394.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-06 19:25 UTC
    CWE
    • CWE-20 - Improper input validation
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls Illustra Standard - L4L China Affected: 0 , < 6.0.0.66394 (custom)
        cpe:2.3:a:johnson_controls:illustra_standard_-_l4l_china:*:*:windows:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-34498",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-06T19:25:49.574695Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-06T19:30:41.991Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "Illustra Standard - L4L China",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "6.0.0.66394",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:illustra_standard_-_l4l_china:*:*:windows:*:*:*:*:*",
                      "versionEndExcluding": "6.0.0.66394",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper input validation vulnerability in Johnson Controls Illustra Standard - L4L China on Windows allows OS Command Injection.\u003cp\u003eThis issue affects Illustra Standard - L4L China: before 6.0.0.66394.\u003c/p\u003e"
                }
              ],
              "value": "Improper input validation vulnerability in Johnson Controls Illustra Standard - L4L China on Windows allows OS Command Injection.\n\nThis issue affects Illustra Standard - L4L China: before 6.0.0.66394."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:H/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper input validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-06T13:52:54.733Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "L4L",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-34498",
        "datePublished": "2026-10-06T13:52:54.733Z",
        "dateReserved": "2026-03-30T08:25:11.763Z",
        "dateUpdated": "2026-10-06T19:30:41.991Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-27873 (GCVE-0-2026-27873)

    Vulnerability from cvelistv5 – Published: 2026-10-01 21:27 – Updated: 2026-10-02 18:23
    VLAI
    Summary
    - Use of Hard-coded Credentials vulnerability in Johnson Controls EasyIO FG allows - Pasword Spraying. This issue affects EasyIO FG: before 2.0b52.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 18:23 UTC
    CWE
    • CWE-798 - - Use of Hard-coded Credentials
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls EasyIO FG Affected: 0 , < 2.0b52 (custom)
        cpe:2.3:a:johnson_controls:easyio_fg:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27873",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T18:23:04.238445Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T18:23:20.952Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO FG",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "2.0b52",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:easyio_fg:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.0b52",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriele Gardois, Zachary Bushell and Lorenzo De Carli"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "- Use of Hard-coded Credentials vulnerability in Johnson Controls EasyIO FG allows - Pasword Spraying.\u003cp\u003eThis issue affects EasyIO FG: before 2.0b52.\u003c/p\u003e"
                }
              ],
              "value": "- Use of Hard-coded Credentials vulnerability in Johnson Controls EasyIO FG allows - Pasword Spraying.\n\nThis issue affects EasyIO FG: before 2.0b52."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-70",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-70 - Pasword Spraying"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 - Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:42:09.453Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-27873",
        "datePublished": "2026-10-01T21:27:33.323Z",
        "dateReserved": "2026-02-24T11:29:18.530Z",
        "dateUpdated": "2026-10-02T18:23:20.952Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-64893 (GCVE-0-2026-64893)

    Vulnerability from cvelistv5 – Published: 2026-10-01 21:25 – Updated: 2026-10-02 19:38
    VLAI
    Summary
    - Cleartext Transmission of Sensitive Information vulnerability in Johnson Controls EasyIO NEO allows - Man In the Middle Attack. This issue affects EasyIO NEO: before 3.3b25.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 19:36 UTC
    CWE
    • CWE-319 - - Cleartext Transmission of Sensitive Information
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls EasyIO NEO Affected: 0 , < 3.3b25 (custom)
        cpe:2.3:a:johnson_controls:easyio_neo:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-64893",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T19:36:46.608058Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T19:38:40.616Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO NEO",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "3.3b25",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:easyio_neo:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "3.3b25",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "- Cleartext Transmission of Sensitive Information vulnerability in Johnson Controls EasyIO NEO allows - Man In the Middle Attack.\u003cp\u003eThis issue affects EasyIO NEO: before 3.3b25.\u003c/p\u003e"
                }
              ],
              "value": "- Cleartext Transmission of Sensitive Information vulnerability in Johnson Controls EasyIO NEO allows - Man In the Middle Attack.\n\nThis issue affects EasyIO NEO: before 3.3b25."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-94",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-94 - Man In the Middle Attack"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:P/VC:H/VI:L/VA:L/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319 - Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:25:26.090Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-64893",
        "datePublished": "2026-10-01T21:25:26.090Z",
        "dateReserved": "2026-07-20T19:51:19.089Z",
        "dateUpdated": "2026-10-02T19:38:40.616Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-64892 (GCVE-0-2026-64892)

    Vulnerability from cvelistv5 – Published: 2026-10-01 21:23 – Updated: 2026-10-02 19:36
    VLAI
    Summary
    - Exposure of Sensitive Information vulnerability in Johnson Controls Easy IO Neo allows Collect Data from Common Resource Locations. This issue affects Easy IO Neo: before 3.3b63.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 19:35 UTC
    CWE
    • CWE-200 - - Exposure of Sensitive Information
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls Easy IO Neo Affected: 0 , < 3.3b63 (custom)
        cpe:2.3:a:johnson_controls:easy_io_neo:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-64892",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T19:35:53.500728Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T19:36:15.187Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Easy IO Neo",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "3.3b63",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:easy_io_neo:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "3.3b63",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "- Exposure of Sensitive Information vulnerability in Johnson Controls Easy IO Neo allows Collect Data from Common Resource Locations.\u003cp\u003eThis issue affects Easy IO Neo: before 3.3b63.\u003c/p\u003e"
                }
              ],
              "value": "- Exposure of Sensitive Information vulnerability in Johnson Controls Easy IO Neo allows Collect Data from Common Resource Locations.\n\nThis issue affects Easy IO Neo: before 3.3b63."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-150",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-150 Collect Data from Common Resource Locations"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:L/VI:N/VA:L/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 - Exposure of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:23:33.947Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-64892",
        "datePublished": "2026-10-01T21:23:33.947Z",
        "dateReserved": "2026-07-20T19:51:19.089Z",
        "dateUpdated": "2026-10-02T19:36:15.187Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-34494 (GCVE-0-2026-34494)

    Vulnerability from cvelistv5 – Published: 2026-10-01 21:20 – Updated: 2026-10-02 19:32
    VLAI
    Summary
    - On-Chip Debug Interface vulnerability in Johnson Controls Neo Series MVP2 allows Collect Data from Common Resource Locations. This issue affects Neo Series MVP2: before 3.3b63.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 19:31 UTC
    CWE
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls Neo Series MVP2 Affected: 0 , < 3.3b63 (custom)
        cpe:2.3:a:johnson_controls:neo_series_mvp2:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-34494",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T19:31:52.885898Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T19:32:25.341Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Neo Series MVP2",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "3.3b63",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:neo_series_mvp2:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "3.3b63",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "- On-Chip Debug Interface vulnerability in Johnson Controls Neo Series MVP2 allows Collect Data from Common Resource Locations.\u003cp\u003eThis issue affects Neo Series MVP2: before 3.3b63.\u003c/p\u003e"
                }
              ],
              "value": "- On-Chip Debug Interface vulnerability in Johnson Controls Neo Series MVP2 allows Collect Data from Common Resource Locations.\n\nThis issue affects Neo Series MVP2: before 3.3b63."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-150",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-150 Collect Data from Common Resource Locations"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:A/VC:N/VI:N/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1191",
                  "description": "CWE-1191 - On-Chip Debug Interface",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:20:55.416Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-34494",
        "datePublished": "2026-10-01T21:20:55.416Z",
        "dateReserved": "2026-03-30T08:25:11.763Z",
        "dateUpdated": "2026-10-02T19:32:25.341Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-34493 (GCVE-0-2026-34493)

    Vulnerability from cvelistv5 – Published: 2026-10-01 21:18 – Updated: 2026-10-02 19:31
    VLAI
    Summary
    - On-Chip Debug Interface vulnerability in Johnson Controls EasyIO FS32 allows Collect Data from Common Resource Locations. This issue affects EasyIO FS32: before 3.3b63.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 19:31 UTC
    CWE
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls EasyIO FS32 Affected: 0 , < 3.3b63 (custom)
        cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-34493",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T19:31:09.143310Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T19:31:33.140Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO FS32",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "3.3b63",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "3.3b63",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "- On-Chip Debug Interface vulnerability in Johnson Controls EasyIO FS32 allows Collect Data from Common Resource Locations.\u003cp\u003eThis issue affects EasyIO FS32: before 3.3b63.\u003c/p\u003e"
                }
              ],
              "value": "- On-Chip Debug Interface vulnerability in Johnson Controls EasyIO FS32 allows Collect Data from Common Resource Locations.\n\nThis issue affects EasyIO FS32: before 3.3b63."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-150",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-150 Collect Data from Common Resource Locations"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:A/VC:N/VI:N/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1191",
                  "description": "CWE-1191 - On-Chip Debug Interface",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:18:55.348Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-34493",
        "datePublished": "2026-10-01T21:18:55.348Z",
        "dateReserved": "2026-03-30T08:25:11.763Z",
        "dateUpdated": "2026-10-02T19:31:33.140Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-71449 (GCVE-0-2026-71449)

    Vulnerability from cvelistv5 – Published: 2026-10-01 21:16 – Updated: 2026-10-02 18:24
    VLAI
    Summary
    : Use of Hard-coded Cryptographic Key vulnerability in Johnson Controls EasyIO FS32 allows : Retrieve Embedded Sensitive Data. This issue affects EasyIO FS32: before 3.0b63.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 18:24 UTC
    CWE
    • CWE-321 - Use of Hard-coded Cryptographic Key
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls EasyIO FS32 Affected: 0 , < 3.0b63 (custom)
        cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-71449",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T18:24:16.543995Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T18:24:34.416Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO FS32",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "3.0b63",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "3.0b63",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriele Gardois, Zachary Bushell and Lorenzo De Carli"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": ": Use of Hard-coded Cryptographic Key vulnerability in Johnson Controls EasyIO FS32 allows : Retrieve Embedded Sensitive Data.\u003cp\u003eThis issue affects EasyIO FS32: before 3.0b63.\u003c/p\u003e"
                }
              ],
              "value": ": Use of Hard-coded Cryptographic Key vulnerability in Johnson Controls EasyIO FS32 allows : Retrieve Embedded Sensitive Data.\n\nThis issue affects EasyIO FS32: before 3.0b63."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-37",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-37: Retrieve Embedded Sensitive Data"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321: Use of Hard-coded Cryptographic Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:44:04.397Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-71449",
        "datePublished": "2026-10-01T21:16:57.610Z",
        "dateReserved": "2026-08-06T19:11:09.315Z",
        "dateUpdated": "2026-10-02T18:24:34.416Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-71448 (GCVE-0-2026-71448)

    Vulnerability from cvelistv5 – Published: 2026-10-01 21:15 – Updated: 2026-10-02 19:29
    VLAI
    Summary
    : Insecure Default Initialization of Resource vulnerability in Johnson Controls EasyIO FS32 allows : Authentication Abuse. This issue affects EasyIO FS32: before 3.0b63.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 19:28 UTC
    CWE
    • CWE-1188 - Insecure Default Initialization of Resource
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls EasyIO FS32 Affected: 0 , < 3.0b63 (custom)
        cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-71448",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T19:28:42.984948Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T19:29:21.270Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO FS32",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "3.0b63",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "3.0b63",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriele Gardois, Zachary Bushell and Lorenzo De Carli"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": ": Insecure Default Initialization of Resource vulnerability in Johnson Controls EasyIO FS32 allows : Authentication Abuse.\u003cp\u003eThis issue affects EasyIO FS32: before 3.0b63.\u003c/p\u003e"
                }
              ],
              "value": ": Insecure Default Initialization of Resource vulnerability in Johnson Controls EasyIO FS32 allows : Authentication Abuse.\n\nThis issue affects EasyIO FS32: before 3.0b63."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115: Authentication Abuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:N/VC:L/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1188",
                  "description": "CWE-1188: Insecure Default Initialization of Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:41:21.737Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-71448",
        "datePublished": "2026-10-01T21:15:22.406Z",
        "dateReserved": "2026-08-06T19:11:09.314Z",
        "dateUpdated": "2026-10-02T19:29:21.270Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-71453 (GCVE-0-2026-71453)

    Vulnerability from cvelistv5 – Published: 2026-10-01 21:10 – Updated: 2026-10-02 19:26
    VLAI
    Summary
    - External Control of File Name or Path vulnerability in Johnson Controls EasyIO FS32 allows - traversal attack. This issue affects EasyIO FS32: before 3.0b63.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 19:26 UTC
    CWE
    • CWE-73 - - External Control of File Name or Path
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls EasyIO FS32 Affected: 0 , < 3.0b63 (custom)
        cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-71453",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T19:26:09.403926Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T19:26:29.901Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO FS32",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "3.0b63",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "3.0b63",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriele Gardois, Zachary Bushell and Lorenzo De Carli"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "- External Control of File Name or Path vulnerability in Johnson Controls EasyIO FS32 allows - traversal attack.\u003cp\u003eThis issue affects EasyIO FS32: before 3.0b63.\u003c/p\u003e"
                }
              ],
              "value": "- External Control of File Name or Path vulnerability in Johnson Controls EasyIO FS32 allows - traversal attack.\n\nThis issue affects EasyIO FS32: before 3.0b63."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 - traversal attack"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:N/VC:L/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-73",
                  "description": "CWE-73 - External Control of File Name or Path",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:40:06.795Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-71453",
        "datePublished": "2026-10-01T21:10:08.583Z",
        "dateReserved": "2026-08-06T19:11:09.315Z",
        "dateUpdated": "2026-10-02T19:26:29.901Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-71452 (GCVE-0-2026-71452)

    Vulnerability from cvelistv5 – Published: 2026-10-01 21:06 – Updated: 2026-10-02 18:25
    VLAI
    Summary
    - OS Command Injection vulnerability in Johnson Controls EasyIO FS32 allows OS Command Injection. This issue affects EasyIO FS32: before 3.0b63.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 18:24 UTC
    CWE
    • CWE-78 - - OS Command Injection
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls EasyIO FS32 Affected: 0 , < 3.0b63 (custom)
        cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-71452",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T18:24:47.167214Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T18:25:00.998Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO FS32",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "3.0b63",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "3.0b63",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriele Gardois, Zachary Bushell and Lorenzo De Carli"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "- OS Command Injection vulnerability in Johnson Controls EasyIO FS32 allows OS Command Injection.\u003cp\u003eThis issue affects EasyIO FS32: before 3.0b63.\u003c/p\u003e"
                }
              ],
              "value": "- OS Command Injection vulnerability in Johnson Controls EasyIO FS32 allows OS Command Injection.\n\nThis issue affects EasyIO FS32: before 3.0b63."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 - OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:43:25.153Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-71452",
        "datePublished": "2026-10-01T21:06:20.659Z",
        "dateReserved": "2026-08-06T19:11:09.315Z",
        "dateUpdated": "2026-10-02T18:25:00.998Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-71451 (GCVE-0-2026-71451)

    Vulnerability from cvelistv5 – Published: 2026-10-01 20:59 – Updated: 2026-10-02 18:26
    VLAI
    Summary
    - OS Command Injection vulnerability in Johnson Controls EasyIO FS32 allows - Command Injection. This issue affects EasyIO FS32: before 3.0b63.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 18:26 UTC
    CWE
    • CWE-78 - - OS Command Injection
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls EasyIO FS32 Affected: 0 , < 3.0b63 (custom)
        cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-71451",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T18:26:06.106597Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T18:26:22.821Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO FS32",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "3.0b63",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "3.0b63",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriele Gardois, Zachary Bushell and Lorenzo De Carli"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "- OS Command Injection vulnerability in Johnson Controls EasyIO FS32 allows - Command Injection.\u003cp\u003eThis issue affects EasyIO FS32: before 3.0b63.\u003c/p\u003e"
                }
              ],
              "value": "- OS Command Injection vulnerability in Johnson Controls EasyIO FS32 allows - Command Injection.\n\nThis issue affects EasyIO FS32: before 3.0b63."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 - Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:N/VC:L/VI:L/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 - OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:43:04.834Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-71451",
        "datePublished": "2026-10-01T20:59:35.064Z",
        "dateReserved": "2026-08-06T19:11:09.315Z",
        "dateUpdated": "2026-10-02T18:26:22.821Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-27874 (GCVE-0-2026-27874)

    Vulnerability from cvelistv5 – Published: 2026-10-01 20:55 – Updated: 2026-10-02 18:27
    VLAI
    Summary
    : Use of Hard-coded Credentials vulnerability in Johnson Controls EasyIO FS32 allows : Exploitation of Default or Hard-coded Credentials. This issue affects EasyIO FS32: before 3.0b63.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-02 18:26 UTC
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls EasyIO FS32 Affected: 0 , < 3.0b63 (custom)
        cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27874",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-02T18:26:59.871789Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-02T18:27:10.203Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyIO FS32",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "3.0b63",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:easyio_fs32:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "3.0b63",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriele Gardois, Zachary Bushell and Lorenzo De Carli"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": ": Use of Hard-coded Credentials vulnerability in Johnson Controls EasyIO FS32 allows : Exploitation of Default or Hard-coded Credentials.\u003cp\u003eThis issue affects EasyIO FS32: before 3.0b63.\u003c/p\u003e"
                }
              ],
              "value": ": Use of Hard-coded Credentials vulnerability in Johnson Controls EasyIO FS32 allows : Exploitation of Default or Hard-coded Credentials.\n\nThis issue affects EasyIO FS32: before 3.0b63."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-112",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-112: Exploitation of Default or Hard-coded Credentials"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798: Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:42:44.495Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-27874",
        "datePublished": "2026-10-01T20:55:59.314Z",
        "dateReserved": "2026-02-24T11:29:18.530Z",
        "dateUpdated": "2026-10-02T18:27:10.203Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-27872 (GCVE-0-2026-27872)

    Vulnerability from cvelistv5 – Published: 2026-10-01 18:57 – Updated: 2026-10-01 21:38
    VLAI
    Title
    EasyIO FG
    Summary
    - Improper Privilege Management vulnerability in Johnson Controls Easy IO FG allows (Brute Force). This issue affects Easy IO FG: before 2.0b52.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-01 19:10 UTC
    CWE
    • CWE-269 - - Improper Privilege Management
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls Easy IO FG Affected: 0 , < 2.0b52 (custom)
        cpe:2.3:a:johnson_controls:easy_io_fg:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27872",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-01T19:10:39.428388Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-01T19:10:49.540Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Easy IO FG",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "2.0b52",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:easy_io_fg:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.0b52",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriele Gardois, Zachary Bushell and Lorenzo De Carli"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "- Improper Privilege Management vulnerability in Johnson Controls Easy IO FG allows (Brute Force).\u003cp\u003eThis issue affects Easy IO FG: before 2.0b52.\u003c/p\u003e"
                }
              ],
              "value": "- Improper Privilege Management vulnerability in Johnson Controls Easy IO FG allows (Brute Force).\n\nThis issue affects Easy IO FG: before 2.0b52."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-30",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-30 (Brute Force)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/E:P",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269 - Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-01T21:38:28.271Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "EasyIO FG",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-27872",
        "datePublished": "2026-10-01T18:57:16.163Z",
        "dateReserved": "2026-02-24T11:29:18.530Z",
        "dateUpdated": "2026-10-01T21:38:28.271Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-64896 (GCVE-0-2026-64896)

    Vulnerability from cvelistv5 – Published: 2026-08-27 14:42 – Updated: 2026-08-27 19:31
    VLAI
    Title
    T2000 open debug port
    Summary
    Debug and Test Interface With Improper Access Control vulnerability in Johnson Controls T2000 allows Accessing Functionality Not Properly Constrained by ACLs. This issue affects T2000: before 31.6.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-27 19:31 UTC
    CWE
    • Debug and Test Interface With Improper Access Control
    • CWE-284 - Improper Access Control
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls T2000 Affected: 0 , < 31.6 (custom)
        cpe:2.3:a:johnson_controls:t2000:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2026-08-25 14:32
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-64896",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-27T19:31:28.626751Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-284",
                    "description": "CWE-284 Improper Access Control",
                    "lang": "en",
                    "type": "CWE"
                  },
                  {
                    "cweId": "CWE-732",
                    "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-27T19:31:48.139Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T2000",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "31.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:t2000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "31.6",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "datePublic": "2026-08-25T14:32:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Debug and Test Interface With Improper Access Control vulnerability in Johnson Controls T2000 allows Accessing Functionality Not Properly Constrained by ACLs.\u003cp\u003eThis issue affects T2000: before 31.6.\u003c/p\u003e"
                }
              ],
              "value": "Debug and Test Interface With Improper Access Control vulnerability in Johnson Controls T2000 allows Accessing Functionality Not Properly Constrained by ACLs.\n\nThis issue affects T2000: before 31.6."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Accessing Functionality Not Properly Constrained by ACLs"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "PHYSICAL",
                "baseScore": 5.2,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Debug and Test Interface With Improper Access Control",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-27T14:42:33.253Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "T2000 open debug port",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003e\u003cp\u003eIf immediate update is not possible, Johnson Controls recommends the following mitigations:\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eRestrict physical access to the device by installing it in a secured equipment room that limits access to authorized service personnel only.\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eImplement tamper-evident seals on device housings and panel enclosures to detect and deter unauthorized physical access attempts.\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eConduct periodic physical inspections of device installations to identify signs of tampering, unauthorized cable connections, or enclosure breaches.\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003eAdditional best-practice mitigations that end users can apply as a layer of defense:\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003ePhysically secure\u0026nbsp;the device\u0026nbsp;enclosure to prevent unauthorized access to internal circuit boards and ports.\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eImplement authentication mechanisms on any accessible debug interfaces to restrict access to authorized service personnel only.\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eMonitor physical access to device installations and implement tamper detection where possible.\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eFollow the recommendations in the Johnson Controls Product Hardening Guide available at\u0026nbsp;\u003ca href=\"https://www.johnsoncontrols.com/trust-center/cybersecurity/resources\" target=\"_blank\" rel=\"noreferrer noopener\"\u003ehttps://www.johnsoncontrols.com/trust-center/cybersecurity/resources\u003c/a\u003e.\u0026nbsp;\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003eThese mitigations reduce risk but may not fully remediate the vulnerability.\u0026nbsp;\u0026nbsp;\u003c/p\u003e\u003c/div\u003e"
                }
              ],
              "value": "If immediate update is not possible, Johnson Controls recommends the following mitigations:\u00a0\n\n\n\n  *  \n\nRestrict physical access to the device by installing it in a secured equipment room that limits access to authorized service personnel only.\u00a0\n\n\n\n\n\n\n  *  \n\nImplement tamper-evident seals on device housings and panel enclosures to detect and deter unauthorized physical access attempts.\u00a0\n\n\n\n\n\n\n  *  \n\nConduct periodic physical inspections of device installations to identify signs of tampering, unauthorized cable connections, or enclosure breaches.\u00a0\n\n\n\n\n\n\n\n\nAdditional best-practice mitigations that end users can apply as a layer of defense:\u00a0\n\n\n\n  *  \n\nPhysically secure\u00a0the device\u00a0enclosure to prevent unauthorized access to internal circuit boards and ports.\u00a0\n\n\n\n\n\n\n  *  \n\nImplement authentication mechanisms on any accessible debug interfaces to restrict access to authorized service personnel only.\u00a0\n\n\n\n\n\n\n  *  \n\nMonitor physical access to device installations and implement tamper detection where possible.\u00a0\n\n\n\n\n\n\n  *  \n\nFollow the recommendations in the Johnson Controls Product Hardening Guide available at\u00a0 https://www.johnsoncontrols.com/trust-center/cybersecurity/resources .\u00a0\n\n\n\n\n\n\n\n\nThese mitigations reduce risk but may not fully remediate the vulnerability."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-64896",
        "datePublished": "2026-08-27T14:42:33.253Z",
        "dateReserved": "2026-07-20T19:51:19.089Z",
        "dateUpdated": "2026-08-27T19:31:48.139Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-34491 (GCVE-0-2026-34491)

    Vulnerability from cvelistv5 – Published: 2026-08-24 17:24 – Updated: 2026-08-25 17:33
    VLAI
    Summary
    Improper neutralization of input during web page generation ('cross-site scripting') vulnerability in Johnson Controls Metasys 14 and Johnson Controls Metasys 15 allows Cross Site Scripting. This issue affects Metasys 14: before 14.1.5; Metasys 15: before 15.0.1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-24 17:44 UTC
    CWE
    • Improper neutralization of input during web page generation ('cross-site scripting')
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    jci CNA under the icscert root
    CNA scorecard C 74/100 over 42 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Johnson Controls Metasys 14 Affected: 0 , < 14.1.5 (custom)
        cpe:2.3:a:johnson_controls:metasys_14:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Johnson Controls Metasys 15 Affected: 0 , < 15.0.1 (custom)
        cpe:2.3:a:johnson_controls:metasys_15:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2026-08-24 17:17
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-34491",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-24T17:44:50.529118Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-79",
                    "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-25T17:33:18.447Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Metasys 14",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "14.1.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Metasys 15",
              "vendor": "Johnson Controls",
              "versions": [
                {
                  "lessThan": "15.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:metasys_14:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "14.1.5",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:johnson_controls:metasys_15:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "15.0.1",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "datePublic": "2026-08-24T17:17:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027) vulnerability in Johnson Controls Metasys 14 and Johnson Controls Metasys 15 allows Cross Site Scripting.\u003cp\u003eThis issue affects Metasys 14: before 14.1.5; Metasys 15: before 15.0.1.\u003c/p\u003e"
                }
              ],
              "value": "Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027) vulnerability in Johnson Controls Metasys 14 and Johnson Controls Metasys 15 allows Cross Site Scripting.\n\nThis issue affects Metasys 14: before 14.1.5; Metasys 15: before 15.0.1."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Cross Site Scripting"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "UNREPORTED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-24T17:24:25.732Z",
            "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
            "shortName": "jci"
          },
          "references": [
            {
              "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "assignerShortName": "jci",
        "cveId": "CVE-2026-34491",
        "datePublished": "2026-08-24T17:24:25.732Z",
        "dateReserved": "2026-03-30T08:25:11.763Z",
        "dateUpdated": "2026-08-25T17:33:18.447Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }