Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for tsxetg3010 by schneider-electric

    CVE-2014-9198 (GCVE-0-2014-9198)

    Vulnerability from nvd – Published: 2015-01-27 11:00 – Updated: 2025-09-05 21:18
    VLAI
    Title
    Schneider Electric ETG3000 FactoryCast HMI Gateway Use of Hard-coded Credentials
    Summary
    The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Schneider Electric ETG3000 FactoryCast HMI Gateway Affected: TSXETG3000
    Affected: TSXETG3010
    Affected: TSXETG3021
    Affected: TSXETG3022
    Create a notification for this product.
    Date Public
    2015-01-20 07:00
    Credits
    Narendra Shinde of Qualys Security
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:40:24.277Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02"
              },
              {
                "name": "72258",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/72258"
              },
              {
                "name": "77765",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/77765"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ETG3000 FactoryCast HMI Gateway",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "TSXETG3000"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3010"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3021"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3022"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Narendra Shinde of Qualys Security"
            }
          ],
          "datePublic": "2015-01-20T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\nThe FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.\n\n\u003c/p\u003e"
                }
              ],
              "value": "The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session."
            }
          ],
          "metrics": [
            {
              "cvssV2_0": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-05T21:18:01.615Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-020-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric has produced an updated firmware, labelled V1.60 \nIR 04. This firmware release moves the jar files directory in a secure \narea. The new firmware also includes the ability to disable the FTP \nserver. This updated firmware can be downloaded at:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe=true\u0026amp;reference=ETG30xxV160-IR04\"\u003ehttp://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe...\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Schneider Electric has produced an updated firmware, labelled V1.60 \nIR 04. This firmware release moves the jar files directory in a secure \narea. The new firmware also includes the ability to disable the FTP \nserver. This updated firmware can be downloaded at:\n\n\n http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe... http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/"
            }
          ],
          "source": {
            "advisory": "ICSA-15-020-02",
            "discovery": "EXTERNAL"
          },
          "title": "Schneider Electric ETG3000 FactoryCast HMI Gateway Use of Hard-coded Credentials",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric recommends the FTP server be deactivated when not \nneeded. The firmware update does not remove the hard-coded credentials.\u003c/p\u003e\n\u003cp\u003eNarendra Shinde also found that configuration files were accessible \nusing default credentials. Schneider Electric recommends users change \nthe default login credentials. This will protect configuration files \nfrom unauthorized access.\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Schneider Electric recommends the FTP server be deactivated when not \nneeded. The firmware update does not remove the hard-coded credentials.\n\n\nNarendra Shinde also found that configuration files were accessible \nusing default credentials. Schneider Electric recommends users change \nthe default login credentials. This will protect configuration files \nfrom unauthorized access."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2014-9197",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2014-9198",
        "datePublished": "2015-01-27T11:00:00.000Z",
        "dateReserved": "2014-12-02T00:00:00.000Z",
        "dateUpdated": "2025-09-05T21:18:01.615Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-9197 (GCVE-0-2014-9197)

    Vulnerability from nvd – Published: 2015-01-27 11:00 – Updated: 2025-09-05 21:19
    VLAI
    Title
    Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function
    Summary
    The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric ETG3000 FactoryCast HMI Gateway Affected: TSXETG3000
    Affected: TSXETG3010
    Affected: TSXETG3021
    Affected: TSXETG3022
    Create a notification for this product.
    Date Public
    2015-01-20 07:00
    Credits
    Narendra Shinde of Qualys Security
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:40:24.525Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ETG3000 FactoryCast HMI Gateway",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "TSXETG3000"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3010"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3021"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3022"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Narendra Shinde of Qualys Security"
            }
          ],
          "datePublic": "2015-01-20T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\n\nThe Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.\n\n\u003c/p\u003e"
                }
              ],
              "value": "The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request."
            }
          ],
          "metrics": [
            {
              "cvssV2_0": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-05T21:19:01.472Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-020-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric has produced an updated firmware, labelled V1.60 \nIR 04. This firmware release moves the jar files directory in a secure \narea. The new firmware also includes the ability to disable the FTP \nserver. This updated firmware can be downloaded at:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe=true\u0026amp;reference=ETG30xxV160-IR04\"\u003ehttp://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe...\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Schneider Electric has produced an updated firmware, labelled V1.60 \nIR 04. This firmware release moves the jar files directory in a secure \narea. The new firmware also includes the ability to disable the FTP \nserver. This updated firmware can be downloaded at:\n\n\n http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe... http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/"
            }
          ],
          "source": {
            "advisory": "ICSA-15-020-02",
            "discovery": "EXTERNAL"
          },
          "title": "Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric recommends the FTP server be deactivated when not \nneeded. The firmware update does not remove the hard-coded credentials.\u003c/p\u003e\n\u003cp\u003eNarendra Shinde also found that configuration files were accessible \nusing default credentials. Schneider Electric recommends users change \nthe default login credentials. This will protect configuration files \nfrom unauthorized access.\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Schneider Electric recommends the FTP server be deactivated when not \nneeded. The firmware update does not remove the hard-coded credentials.\n\n\nNarendra Shinde also found that configuration files were accessible \nusing default credentials. Schneider Electric recommends users change \nthe default login credentials. This will protect configuration files \nfrom unauthorized access."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2014-9197",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2014-9197",
        "datePublished": "2015-01-27T11:00:00.000Z",
        "dateReserved": "2014-12-02T00:00:00.000Z",
        "dateUpdated": "2025-09-05T21:19:01.472Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-9198 (GCVE-0-2014-9198)

    Vulnerability from cvelistv5 – Published: 2015-01-27 11:00 – Updated: 2025-09-05 21:18
    VLAI
    Title
    Schneider Electric ETG3000 FactoryCast HMI Gateway Use of Hard-coded Credentials
    Summary
    The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Schneider Electric ETG3000 FactoryCast HMI Gateway Affected: TSXETG3000
    Affected: TSXETG3010
    Affected: TSXETG3021
    Affected: TSXETG3022
    Create a notification for this product.
    Date Public
    2015-01-20 07:00
    Credits
    Narendra Shinde of Qualys Security
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:40:24.277Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02"
              },
              {
                "name": "72258",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/72258"
              },
              {
                "name": "77765",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/77765"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ETG3000 FactoryCast HMI Gateway",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "TSXETG3000"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3010"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3021"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3022"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Narendra Shinde of Qualys Security"
            }
          ],
          "datePublic": "2015-01-20T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\nThe FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.\n\n\u003c/p\u003e"
                }
              ],
              "value": "The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session."
            }
          ],
          "metrics": [
            {
              "cvssV2_0": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-05T21:18:01.615Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-020-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric has produced an updated firmware, labelled V1.60 \nIR 04. This firmware release moves the jar files directory in a secure \narea. The new firmware also includes the ability to disable the FTP \nserver. This updated firmware can be downloaded at:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe=true\u0026amp;reference=ETG30xxV160-IR04\"\u003ehttp://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe...\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Schneider Electric has produced an updated firmware, labelled V1.60 \nIR 04. This firmware release moves the jar files directory in a secure \narea. The new firmware also includes the ability to disable the FTP \nserver. This updated firmware can be downloaded at:\n\n\n http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe... http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/"
            }
          ],
          "source": {
            "advisory": "ICSA-15-020-02",
            "discovery": "EXTERNAL"
          },
          "title": "Schneider Electric ETG3000 FactoryCast HMI Gateway Use of Hard-coded Credentials",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric recommends the FTP server be deactivated when not \nneeded. The firmware update does not remove the hard-coded credentials.\u003c/p\u003e\n\u003cp\u003eNarendra Shinde also found that configuration files were accessible \nusing default credentials. Schneider Electric recommends users change \nthe default login credentials. This will protect configuration files \nfrom unauthorized access.\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Schneider Electric recommends the FTP server be deactivated when not \nneeded. The firmware update does not remove the hard-coded credentials.\n\n\nNarendra Shinde also found that configuration files were accessible \nusing default credentials. Schneider Electric recommends users change \nthe default login credentials. This will protect configuration files \nfrom unauthorized access."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2014-9197",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2014-9198",
        "datePublished": "2015-01-27T11:00:00.000Z",
        "dateReserved": "2014-12-02T00:00:00.000Z",
        "dateUpdated": "2025-09-05T21:18:01.615Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2014-9197 (GCVE-0-2014-9197)

    Vulnerability from cvelistv5 – Published: 2015-01-27 11:00 – Updated: 2025-09-05 21:19
    VLAI
    Title
    Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function
    Summary
    The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric ETG3000 FactoryCast HMI Gateway Affected: TSXETG3000
    Affected: TSXETG3010
    Affected: TSXETG3021
    Affected: TSXETG3022
    Create a notification for this product.
    Date Public
    2015-01-20 07:00
    Credits
    Narendra Shinde of Qualys Security
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T13:40:24.525Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ETG3000 FactoryCast HMI Gateway",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "TSXETG3000"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3010"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3021"
                },
                {
                  "status": "affected",
                  "version": "TSXETG3022"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Narendra Shinde of Qualys Security"
            }
          ],
          "datePublic": "2015-01-20T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\n\nThe Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.\n\n\u003c/p\u003e"
                }
              ],
              "value": "The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request."
            }
          ],
          "metrics": [
            {
              "cvssV2_0": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-05T21:19:01.472Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-020-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric has produced an updated firmware, labelled V1.60 \nIR 04. This firmware release moves the jar files directory in a secure \narea. The new firmware also includes the ability to disable the FTP \nserver. This updated firmware can be downloaded at:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe=true\u0026amp;reference=ETG30xxV160-IR04\"\u003ehttp://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe...\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Schneider Electric has produced an updated firmware, labelled V1.60 \nIR 04. This firmware release moves the jar files directory in a secure \narea. The new firmware also includes the ability to disable the FTP \nserver. This updated firmware can be downloaded at:\n\n\n http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe... http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/"
            }
          ],
          "source": {
            "advisory": "ICSA-15-020-02",
            "discovery": "EXTERNAL"
          },
          "title": "Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eSchneider Electric recommends the FTP server be deactivated when not \nneeded. The firmware update does not remove the hard-coded credentials.\u003c/p\u003e\n\u003cp\u003eNarendra Shinde also found that configuration files were accessible \nusing default credentials. Schneider Electric recommends users change \nthe default login credentials. This will protect configuration files \nfrom unauthorized access.\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Schneider Electric recommends the FTP server be deactivated when not \nneeded. The firmware update does not remove the hard-coded credentials.\n\n\nNarendra Shinde also found that configuration files were accessible \nusing default credentials. Schneider Electric recommends users change \nthe default login credentials. This will protect configuration files \nfrom unauthorized access."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2014-9197",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-020-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2014-9197",
        "datePublished": "2015-01-27T11:00:00.000Z",
        "dateReserved": "2014-12-02T00:00:00.000Z",
        "dateUpdated": "2025-09-05T21:19:01.472Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }