Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for triconex_tricon_mp_3008_firmware by schneider-electric

    FKIE_CVE-2018-8872

    Vulnerability from fkie_nvd - Published: 2018-05-04 17:29 - Updated: 2026-06-17 02:05
    Summary
    In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "Triconex Tricon",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "MP model 3008 firmware versions 10.0-10.4"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:triconex_tricon_mp_3008_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6A170B3E-344C-45F1-BE91-803564D487E8",
                  "versionEndIncluding": "10.4",
                  "versionStartIncluding": "10.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:triconex_tricon_mp_3008:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1A4185CD-357B-4160-A3CC-5977590A80EF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory."
        },
        {
          "lang": "es",
          "value": "En Schneider Electric Triconex Tricon MP modelo 3008 con versiones de firmware 10.0-10.4, las llamadas del sistema leen directamente de las direcciones de memoria en el \u00e1rea del programa de control sin ning\u00fan tipo de verificaci\u00f3n. La manipulaci\u00f3n de estos datos podr\u00eda permitir que los datos del atacante se copien en cualquier sitio de la memoria."
        }
      ],
      "id": "CVE-2018-8872",
      "lastModified": "2026-06-17T02:05:33.667",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 9.3,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-05-04T17:29:00.723",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/103947"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/103947"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-7522

    Vulnerability from fkie_nvd - Published: 2018-05-04 17:29 - Updated: 2026-06-17 02:03
    Summary
    In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "Triconex Tricon",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "MP model 3008 firmware versions 10.0-10.4"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:triconex_tricon_mp_3008_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3D44B765-DDC3-488E-93EE-E9471E927A7C",
                  "versionEndIncluding": "10.0-10.4",
                  "versionStartIncluding": "10.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:triconex_tricon_mp_3008:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1A4185CD-357B-4160-A3CC-5977590A80EF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states."
        },
        {
          "lang": "es",
          "value": "En Schneider Electric Triconex Tricon MP modelo 3008, con versiones de firmware 10.0-10.4, cuando se realiza una llamada del sistema, los registros se almacenan en una ubicaci\u00f3n fija de la memoria. La modificaci\u00f3n de los datos en esta ubicaci\u00f3n podr\u00eda permitir que atacantes obtengan acceso de nivel supervisor y controlen los estados del sistema."
        }
      ],
      "id": "CVE-2018-7522",
      "lastModified": "2026-06-17T02:03:17.803",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 7.2,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.7,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 0.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-05-04T17:29:00.393",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/103947"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/103947"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2018-8872 (GCVE-0-2018-8872)

    Vulnerability from nvd – Published: 2018-05-04 17:00 – Updated: 2024-09-16 16:32
    VLAI
    Summary
    In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
    Severity
    No CVSS data available.
    CWE
    • CWE-119 - Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric Triconex Tricon Affected: MP model 3008 firmware versions 10.0-10.4
    Create a notification for this product.
    Date Public
    2018-04-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:10:46.217Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
              },
              {
                "name": "103947",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/103947"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Triconex Tricon",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "MP model 3008 firmware versions 10.0-10.4"
                }
              ]
            }
          ],
          "datePublic": "2018-04-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-05T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
            },
            {
              "name": "103947",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/103947"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-04-17T00:00:00",
              "ID": "CVE-2018-8872",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Triconex Tricon",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "MP model 3008 firmware versions 10.0-10.4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
                },
                {
                  "name": "103947",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/103947"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-8872",
        "datePublished": "2018-05-04T17:00:00.000Z",
        "dateReserved": "2018-03-20T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:32:36.977Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7522 (GCVE-0-2018-7522)

    Vulnerability from nvd – Published: 2018-05-04 17:00 – Updated: 2024-09-17 00:02
    VLAI
    Summary
    In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.
    Severity
    No CVSS data available.
    CWE
    • CWE-119 - Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric Triconex Tricon Affected: MP model 3008 firmware versions 10.0-10.4
    Create a notification for this product.
    Date Public
    2018-04-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:31:04.336Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
              },
              {
                "name": "103947",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/103947"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Triconex Tricon",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "MP model 3008 firmware versions 10.0-10.4"
                }
              ]
            }
          ],
          "datePublic": "2018-04-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-05T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
            },
            {
              "name": "103947",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/103947"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-04-17T00:00:00",
              "ID": "CVE-2018-7522",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Triconex Tricon",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "MP model 3008 firmware versions 10.0-10.4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
                },
                {
                  "name": "103947",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/103947"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-7522",
        "datePublished": "2018-05-04T17:00:00.000Z",
        "dateReserved": "2018-02-26T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:02:25.672Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-8872 (GCVE-0-2018-8872)

    Vulnerability from cvelistv5 – Published: 2018-05-04 17:00 – Updated: 2024-09-16 16:32
    VLAI
    Summary
    In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
    Severity
    No CVSS data available.
    CWE
    • CWE-119 - Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric Triconex Tricon Affected: MP model 3008 firmware versions 10.0-10.4
    Create a notification for this product.
    Date Public
    2018-04-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:10:46.217Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
              },
              {
                "name": "103947",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/103947"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Triconex Tricon",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "MP model 3008 firmware versions 10.0-10.4"
                }
              ]
            }
          ],
          "datePublic": "2018-04-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-05T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
            },
            {
              "name": "103947",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/103947"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-04-17T00:00:00",
              "ID": "CVE-2018-8872",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Triconex Tricon",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "MP model 3008 firmware versions 10.0-10.4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
                },
                {
                  "name": "103947",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/103947"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-8872",
        "datePublished": "2018-05-04T17:00:00.000Z",
        "dateReserved": "2018-03-20T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:32:36.977Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7522 (GCVE-0-2018-7522)

    Vulnerability from cvelistv5 – Published: 2018-05-04 17:00 – Updated: 2024-09-17 00:02
    VLAI
    Summary
    In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.
    Severity
    No CVSS data available.
    CWE
    • CWE-119 - Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric Triconex Tricon Affected: MP model 3008 firmware versions 10.0-10.4
    Create a notification for this product.
    Date Public
    2018-04-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:31:04.336Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
              },
              {
                "name": "103947",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/103947"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Triconex Tricon",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "MP model 3008 firmware versions 10.0-10.4"
                }
              ]
            }
          ],
          "datePublic": "2018-04-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-05-05T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
            },
            {
              "name": "103947",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/103947"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-04-17T00:00:00",
              "ID": "CVE-2018-7522",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Triconex Tricon",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "MP model 3008 firmware versions 10.0-10.4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"
                },
                {
                  "name": "103947",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/103947"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-7522",
        "datePublished": "2018-05-04T17:00:00.000Z",
        "dateReserved": "2018-02-26T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:02:25.672Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }