Search criteria
6 vulnerabilities found for sysmac_studio by omron
CVE-2022-45792 (GCVE-0-2022-45792)
Vulnerability from nvd – Published: 2024-01-22 17:46 – Updated: 2025-06-17 21:19
VLAI?
Title
Directory Traversal in Project File Format allows overwrite (Zip Slip)
Summary
Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user.
Severity ?
7.8 (High)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Omron | Sysmac Studio |
Affected:
0 , < 1.54.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:17:04.101Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dragos.com/advisory/omron-plc-and-engineering-software-network-and-file-format-access/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45792",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-30T18:36:27.204028Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T21:19:25.577Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows",
"x86",
"64 bit"
],
"product": "Sysmac Studio",
"vendor": "Omron",
"versions": [
{
"lessThan": "1.54.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user."
}
],
"value": "Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user."
}
],
"impacts": [
{
"capecId": "CAPEC-165",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-165 File Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-22T17:46:36.699Z",
"orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"shortName": "Dragos"
},
"references": [
{
"url": "https://www.dragos.com/advisory/omron-plc-and-engineering-software-network-and-file-format-access/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Directory Traversal in Project File Format allows overwrite (Zip Slip)",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"assignerShortName": "Dragos",
"cveId": "CVE-2022-45792",
"datePublished": "2024-01-22T17:46:36.699Z",
"dateReserved": "2022-11-22T17:52:43.198Z",
"dateUpdated": "2025-06-17T21:19:25.577Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-34151 (GCVE-0-2022-34151)
Vulnerability from nvd – Published: 2022-07-04 01:51 – Updated: 2024-08-03 08:16
VLAI?
Summary
Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller.
Severity ?
No CVSS data available.
CWE
- Use of Hard-coded Credentials
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| OMRON Corporation | Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series |
Affected:
Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:16:17.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
"vendor": "OMRON Corporation",
"versions": [
{
"status": "affected",
"version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Use of Hard-coded Credentials",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-04T02:25:19",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2022-34151",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
"version": {
"version_data": [
{
"version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
}
]
}
}
]
},
"vendor_name": "OMRON Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Use of Hard-coded Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
"refsource": "MISC",
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2022-34151",
"datePublished": "2022-07-04T01:51:00",
"dateReserved": "2022-06-21T00:00:00",
"dateUpdated": "2024-08-03T08:16:17.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-33208 (GCVE-0-2022-33208)
Vulnerability from nvd – Published: 2022-07-04 01:50 – Updated: 2024-08-03 08:01
VLAI?
Summary
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software 'Sysmac Studio' and/or a Programmable Terminal (PT) to access the controller.
Severity ?
No CVSS data available.
CWE
- Authentication Bypass by Capture-replay
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| OMRON Corporation | Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series |
Affected:
Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:01:20.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
"vendor": "OMRON Corporation",
"versions": [
{
"status": "affected",
"version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Authentication Bypass by Capture-replay",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-04T02:25:11",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2022-33208",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
"version": {
"version_data": [
{
"version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
}
]
}
}
]
},
"vendor_name": "OMRON Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Authentication Bypass by Capture-replay"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
"refsource": "MISC",
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2022-33208",
"datePublished": "2022-07-04T01:50:44",
"dateReserved": "2022-06-21T00:00:00",
"dateUpdated": "2024-08-03T08:01:20.422Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-45792 (GCVE-0-2022-45792)
Vulnerability from cvelistv5 – Published: 2024-01-22 17:46 – Updated: 2025-06-17 21:19
VLAI?
Title
Directory Traversal in Project File Format allows overwrite (Zip Slip)
Summary
Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user.
Severity ?
7.8 (High)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Omron | Sysmac Studio |
Affected:
0 , < 1.54.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:17:04.101Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dragos.com/advisory/omron-plc-and-engineering-software-network-and-file-format-access/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-45792",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-30T18:36:27.204028Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T21:19:25.577Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows",
"x86",
"64 bit"
],
"product": "Sysmac Studio",
"vendor": "Omron",
"versions": [
{
"lessThan": "1.54.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user."
}
],
"value": "Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user."
}
],
"impacts": [
{
"capecId": "CAPEC-165",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-165 File Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-22T17:46:36.699Z",
"orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"shortName": "Dragos"
},
"references": [
{
"url": "https://www.dragos.com/advisory/omron-plc-and-engineering-software-network-and-file-format-access/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Directory Traversal in Project File Format allows overwrite (Zip Slip)",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"assignerShortName": "Dragos",
"cveId": "CVE-2022-45792",
"datePublished": "2024-01-22T17:46:36.699Z",
"dateReserved": "2022-11-22T17:52:43.198Z",
"dateUpdated": "2025-06-17T21:19:25.577Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-34151 (GCVE-0-2022-34151)
Vulnerability from cvelistv5 – Published: 2022-07-04 01:51 – Updated: 2024-08-03 08:16
VLAI?
Summary
Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller.
Severity ?
No CVSS data available.
CWE
- Use of Hard-coded Credentials
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| OMRON Corporation | Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series |
Affected:
Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:16:17.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
"vendor": "OMRON Corporation",
"versions": [
{
"status": "affected",
"version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Use of Hard-coded Credentials",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-04T02:25:19",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2022-34151",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
"version": {
"version_data": [
{
"version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
}
]
}
}
]
},
"vendor_name": "OMRON Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Use of Hard-coded Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
"refsource": "MISC",
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2022-34151",
"datePublished": "2022-07-04T01:51:00",
"dateReserved": "2022-06-21T00:00:00",
"dateUpdated": "2024-08-03T08:16:17.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-33208 (GCVE-0-2022-33208)
Vulnerability from cvelistv5 – Published: 2022-07-04 01:50 – Updated: 2024-08-03 08:01
VLAI?
Summary
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software 'Sysmac Studio' and/or a Programmable Terminal (PT) to access the controller.
Severity ?
No CVSS data available.
CWE
- Authentication Bypass by Capture-replay
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| OMRON Corporation | Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series |
Affected:
Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:01:20.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
"vendor": "OMRON Corporation",
"versions": [
{
"status": "affected",
"version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Authentication Bypass by Capture-replay",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-04T02:25:11",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2022-33208",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
"version": {
"version_data": [
{
"version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
}
]
}
}
]
},
"vendor_name": "OMRON Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Authentication Bypass by Capture-replay"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
"refsource": "MISC",
"url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
},
{
"name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2022-33208",
"datePublished": "2022-07-04T01:50:44",
"dateReserved": "2022-06-21T00:00:00",
"dateUpdated": "2024-08-03T08:01:20.422Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}