Search

Find a vulnerability

Search criteria

    18 vulnerabilities found for spectrum_power_7 by siemens

    CVE-2026-109619 (GCVE-0-2026-109619)

    Vulnerability from nvd – Published: 2026-10-21 13:54 – Updated: 2026-11-18 18:32
    VLAI CISA Shadowserver Previdian
    Title
    RCE via stale global state
    Summary
    PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE).
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2026-10-21 00:00 UTC
    CWE
    • CWE-416 - Use after free
    • CWE-755 - Improper Handling of Exceptional Conditions
    • CWE-824 - Access of uninitialized pointer
    • CWE-1325 - Improperly controlled sequential memory allocation
    • CWE-1419 - Incorrect Initialization of Resource
    Assigner
    php CNA under the mitre root
    CNA scorecard B 82/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    PHP Group PHP Affected: 8.2.* , < 8.2.35 (semver)
    Affected: 8.3.* , < 8.3.36 (semver)
    Affected: 8.4.* , < 8.4.27 (semver)
    Affected: 8.5.* , < 8.5.12 (semver)
    Create a notification for this product.
    Siemens AMIS TS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens AX4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX - S Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Building X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens CADRA Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Call stations Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Capital Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Chargesight Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Cloud IC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Devices Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect Insights Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X200 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X300 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X500 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens cRSP Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Depotfinity Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Essentials Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR2 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo Optic Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC5 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC7 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens DFMExpress Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V2.0SP9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V3.1SP1 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Management System Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted RTLS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted Space Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox H60 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Rapid Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Local Monitoring bt-monitoring-vm Affected: 0 , < V20261103 (custom)
    Create a notification for this product.
    Siemens Navigator E&S Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Unaffected: 0 , < * (custom)
    Create a notification for this product.

    50 of 110 products shown. All of them on the page of CVE-2026-109619.

    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-109619",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-21T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2026-10-26",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:47.838Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://www.wiz.io/blog/php2shell-php-rce"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://php2shell.delftintellab.com/"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2026-10-26T00:00:00.000Z",
                "value": "CVE-2026-109619 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-10-23T14:07:57.152Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/7"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/17"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/23"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/2"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/14"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/15"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/19"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/20"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/4"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "AMIS TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "AX4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX - S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Building X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "CADRA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Call stations",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Capital",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Chargesight",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Cloud IC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Devices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect Insights",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X200",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X300",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X500",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "cRSP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Depotfinity",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo Optic",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DFMExpress",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V2.0SP9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V3.1SP1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Management System",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted RTLS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted Space",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox H60",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Rapid",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Local Monitoring bt-monitoring-vm",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V20261103",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Navigator E\u0026S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PACE-Design",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard \u0026 Standard Plus",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Pathway to Learning Engineering",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Polarion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "QuadView",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D Configuration Backend",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flomaster",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flux",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Simlab",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sinteso FS20 EN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SiPass integrated",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPORT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Intrusion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Video",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power TG",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Supply Chain Suite",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Product Cost Management",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Share",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Visualization",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Tecnomatix Plant Simulation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TestWay",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Valor NPI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Verischarge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloudHeliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm panels",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm systems and audio matrices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Workplace Experience",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV676-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "FW6.9.22-3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV776-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xcargo",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition IC Packaging",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Layout Browser",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-18T18:32:28.496Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "php-src",
              "product": "PHP",
              "vendor": "PHP Group",
              "versions": [
                {
                  "lessThan": "8.2.35",
                  "status": "affected",
                  "version": "8.2.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.3.36",
                  "status": "affected",
                  "version": "8.3.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.4.27",
                  "status": "affected",
                  "version": "8.4.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.5.12",
                  "status": "affected",
                  "version": "8.5.*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Wiz"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "Ryan at Calif.io"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "OpenAI"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Arnaud Le Blanc"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Ilija Tovilo"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Jakub Zelenka"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Nora Dossche"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
                }
              ],
              "value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-234",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-234 Hijacking a privileged process"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416 Use after free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755 Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824 Access of uninitialized pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1325",
                  "description": "CWE-1325 Improperly controlled sequential memory allocation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1419",
                  "description": "CWE-1419 Incorrect Initialization of Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T13:54:43.866Z",
            "orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
            "shortName": "php"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://github.com/php/php-src/security/advisories/GHSA-6wmf-4rv5-p3rp"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "RCE via stale global state",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Check the GitHub Security Advisory for mitigation strategies."
                }
              ],
              "value": "Check the GitHub Security Advisory for mitigation strategies."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
        "assignerShortName": "php",
        "cveId": "CVE-2026-109619",
        "datePublished": "2026-10-21T13:54:43.866Z",
        "dateReserved": "2026-10-12T21:04:00.504Z",
        "dateUpdated": "2026-11-18T18:32:28.496Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-109618 (GCVE-0-2026-109618)

    Vulnerability from nvd – Published: 2026-10-21 13:48 – Updated: 2026-11-18 18:32
    VLAI CISA Shadowserver Previdian
    Title
    RCE via OOM corruption
    Summary
    PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2026-10-21 00:00 UTC
    CWE
    • CWE-416 - Use after free
    • CWE-755 - Improper Handling of Exceptional Conditions
    • CWE-824 - Access of uninitialized pointer
    • CWE-1325 - Improperly controlled sequential memory allocation
    • CWE-1419 - Incorrect Initialization of Resource
    Assigner
    php CNA under the mitre root
    CNA scorecard B 82/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    PHP Group PHP Affected: 8.2.* , < 8.2.35 (semver)
    Affected: 8.3.* , < 8.3.36 (semver)
    Affected: 8.4.* , < 8.4.27 (semver)
    Affected: 8.5.* , < 8.5.12 (semver)
    Create a notification for this product.
    Siemens AMIS TS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens AX4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX - S Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Building X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens CADRA Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Call stations Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Capital Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Chargesight Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Cloud IC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Devices Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect Insights Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X200 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X300 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X500 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens cRSP Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Depotfinity Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Essentials Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR2 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo Optic Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC5 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC7 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens DFMExpress Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V2.0SP9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V3.1SP1 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Management System Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted RTLS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted Space Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox H60 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Rapid Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Local Monitoring bt-monitoring-vm Affected: 0 , < V20261103 (custom)
    Create a notification for this product.
    Siemens Navigator E&S Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Unaffected: 0 , < * (custom)
    Create a notification for this product.

    50 of 109 products shown. All of them on the page of CVE-2026-109618.

    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-109618",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-21T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2026-10-26",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:46.712Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://www.wiz.io/blog/php2shell-php-rce"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://php2shell.delftintellab.com"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2026-10-26T00:00:00.000Z",
                "value": "CVE-2026-109618 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-15T00:15:58.835Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/5"
              },
              {
                "url": "http://seclists.org/fulldisclosure/2026/Oct/51"
              },
              {
                "url": "https://github.com/rapid7/metasploit-framework/pull/22139"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "AMIS TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "AX4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX - S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Building X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "CADRA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Call stations",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Capital",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Chargesight",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Cloud IC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Devices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect Insights",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X200",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X300",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X500",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "cRSP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Depotfinity",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo Optic",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DFMExpress",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V2.0SP9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V3.1SP1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Management System",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted RTLS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted Space",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox H60",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Rapid",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Local Monitoring bt-monitoring-vm",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V20261103",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Navigator E\u0026S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PACE-Design",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard \u0026 Standard Plus",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Pathway to Learning Engineering",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Polarion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "QuadView",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D Configuration Backend",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flomaster",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flux",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Simlab",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sinteso FS20 EN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SiPass integrated",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPORT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Intrusion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Video",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power TG",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Supply Chain Suite",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Product Cost Management",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Share",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Visualization",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Tecnomatix Plant Simulation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TestWay",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Valor NPI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Verischarge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloudHeliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm panels",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm systems and audio matrices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Workplace Experience",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV676-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "FW6.9.22-3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV776-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xcargo",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition IC Packaging",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Layout Browser",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-18T18:32:27.150Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "php-src",
              "product": "PHP",
              "vendor": "PHP Group",
              "versions": [
                {
                  "lessThan": "8.2.35",
                  "status": "affected",
                  "version": "8.2.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.3.36",
                  "status": "affected",
                  "version": "8.3.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.4.27",
                  "status": "affected",
                  "version": "8.4.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.5.12",
                  "status": "affected",
                  "version": "8.5.*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Ryan at Calif.io"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "Wiz"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Arnaud Le Blanc"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Ilija Tovilo"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Jakub Zelenka"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Nora Dossche"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).\u003cbr\u003e"
                }
              ],
              "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE)."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-234",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-234 Hijacking a privileged process"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416 Use after free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755 Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824 Access of uninitialized pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1325",
                  "description": "CWE-1325 Improperly controlled sequential memory allocation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1419",
                  "description": "CWE-1419 Incorrect Initialization of Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T13:48:34.845Z",
            "orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
            "shortName": "php"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "RCE via OOM corruption",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Check the GitHub Security Advisory for mitigation strategies."
                }
              ],
              "value": "Check the GitHub Security Advisory for mitigation strategies."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
        "assignerShortName": "php",
        "cveId": "CVE-2026-109618",
        "datePublished": "2026-10-21T13:48:34.845Z",
        "dateReserved": "2026-10-12T21:03:58.117Z",
        "dateUpdated": "2026-11-18T18:32:27.150Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-29119 (GCVE-0-2024-29119)

    Vulnerability from nvd – Published: 2024-11-12 12:49 – Updated: 2024-11-12 14:38
    VLAI
    Summary
    A vulnerability has been identified in Spectrum Power 7 (All versions < V24Q3). The affected product contains several root-owned SUID binaries that could allow an authenticated local attacker to escalate privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2024-11-12 14:36 UTC
    CWE
    • CWE-266 - Incorrect Privilege Assignment
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens Spectrum Power 7 Affected: 0 , < V24Q3 (custom)
    Create a notification for this product.
    siemens spectrum_power_7 Affected: 0 , < v24q3 (custom)
        cpe:2.3:a:siemens:spectrum_power_7:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:spectrum_power_7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "spectrum_power_7",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "v24q3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-29119",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-12T14:36:34.804870Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-12T14:38:15.692Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Spectrum Power 7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V24Q3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V24Q3). The affected product contains several root-owned SUID binaries that could allow an authenticated local attacker to escalate privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "CWE-266: Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-12T12:49:27.011Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-616032.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-29119",
        "datePublished": "2024-11-12T12:49:27.011Z",
        "dateReserved": "2024-03-15T19:27:44.950Z",
        "dateUpdated": "2024-11-12T14:38:15.692Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-44120 (GCVE-0-2023-44120)

    Vulnerability from nvd – Published: 2024-01-09 09:59 – Updated: 2024-11-14 15:24
    VLAI
    Summary
    A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q4). The affected product's sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2024-01-22 20:23 UTC
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens Spectrum Power 7 Affected: All versions < V23Q4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T19:59:51.225Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-44120",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-22T20:23:10.458980Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-14T15:24:09.445Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Spectrum Power 7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V23Q4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-09T09:59:44.755Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-44120",
        "datePublished": "2024-01-09T09:59:44.755Z",
        "dateReserved": "2023-09-25T10:24:56.157Z",
        "dateUpdated": "2024-11-14T15:24:09.445Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38557 (GCVE-0-2023-38557)

    Vulnerability from nvd – Published: 2023-09-14 10:39 – Updated: 2025-02-27 20:50
    VLAI
    Summary
    A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q3). The affected product assigns improper access rights to the update script. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2025-02-26 21:51 UTC
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens Spectrum Power 7 Affected: All versions < V23Q3
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:46:56.237Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-357182.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-38557",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-26T21:51:13.615641Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-27T20:50:26.366Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Spectrum Power 7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V23Q3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q3). The affected product assigns improper access rights to the update script. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-09-14T10:39:28.689Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-357182.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-38557",
        "datePublished": "2023-09-14T10:39:28.689Z",
        "dateReserved": "2023-07-20T08:17:26.143Z",
        "dateUpdated": "2025-02-27T20:50:26.366Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26476 (GCVE-0-2022-26476)

    Vulnerability from nvd – Published: 2022-06-14 09:21 – Updated: 2024-08-03 05:03
    VLAI
    Summary
    A vulnerability has been identified in Spectrum Power 4 (All versions using Shared HIS), Spectrum Power 7 (All versions using Shared HIS), Spectrum Power MGMS (All versions using Shared HIS). An unauthenticated attacker could log into the component Shared HIS used in Spectrum Power systems by using an account with default credentials. A successful exploitation could allow the attacker to access the component Shared HIS with administrative privileges.
    Severity
    No CVSS data available.
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Siemens Spectrum Power 4 Affected: All versions using Shared HIS
    Create a notification for this product.
    Siemens Spectrum Power 7 Affected: All versions using Shared HIS
    Create a notification for this product.
    Siemens Spectrum Power MGMS Affected: All versions using Shared HIS
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.863Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-388239.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Spectrum Power 4",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions using Shared HIS"
                }
              ]
            },
            {
              "product": "Spectrum Power 7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions using Shared HIS"
                }
              ]
            },
            {
              "product": "Spectrum Power MGMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions using Shared HIS"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Spectrum Power 4 (All versions using Shared HIS), Spectrum Power 7 (All versions using Shared HIS), Spectrum Power MGMS (All versions using Shared HIS). An unauthenticated attacker could log into the component Shared HIS used in Spectrum Power systems by using an account with default credentials. A successful exploitation could allow the attacker to access the component Shared HIS with administrative privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798: Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-14T09:21:38.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-388239.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2022-26476",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Spectrum Power 4",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions using Shared HIS"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Spectrum Power 7",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions using Shared HIS"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Spectrum Power MGMS",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions using Shared HIS"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Spectrum Power 4 (All versions using Shared HIS), Spectrum Power 7 (All versions using Shared HIS), Spectrum Power MGMS (All versions using Shared HIS). An unauthenticated attacker could log into the component Shared HIS used in Spectrum Power systems by using an account with default credentials. A successful exploitation could allow the attacker to access the component Shared HIS with administrative privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-798: Use of Hard-coded Credentials"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-388239.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-388239.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2022-26476",
        "datePublished": "2022-06-14T09:21:38.000Z",
        "dateReserved": "2022-03-04T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:03:32.863Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-45046 (GCVE-0-2021-45046)

    Vulnerability from nvd – Published: 2021-12-14 16:55 – Updated: 2025-10-21 23:25
    VLAI CISA Previdian
    Title
    Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack
    Summary
    It was found that the fix to address CVE-2021-44228 in Apache Log4j 2.15.0 was incomplete in certain non-default configurations. This could allows attackers with control over Thread Context Map (MDC) input data when the logging configuration uses a non-default Pattern Layout with either a Context Lookup (for example, $${ctx:loginId}) or a Thread Context Map pattern (%X, %mdc, or %MDC) to craft malicious input data using a JNDI Lookup pattern resulting in an information leak and remote code execution in some environments and local code execution in all environments. Log4j 2.16.0 (Java 8) and 2.12.2 (Java 7) fix this issue by removing support for message lookup patterns and disabling JNDI functionality by default.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2025-02-04 19:31 UTC
    CWE
    • CWE-917 - Improper Neutralization of Special Elements used in an Expression Language Statement ('Expression Language Injection')
    Assigner
    apache CNA under the mitre root
    CNA scorecard B 76/100 over 1271 records in the last 180 days details
    References
    URL Tags
    https://psirt.global.sonicwall.com/vuln-detail/SN… x_refsource_CONFIRM
    https://www.oracle.com/security-alerts/alert-cve-… x_refsource_CONFIRM
    https://www.cve.org/CVERecord?id=CVE-2021-44228 x_refsource_MISC
    http://www.openwall.com/lists/oss-security/2021/12/14/4 mailing-listx_refsource_MLIST
    https://logging.apache.org/log4j/2.x/security.html x_refsource_CONFIRM
    https://www.kb.cert.org/vuls/id/930724 third-party-advisoryx_refsource_CERT-VN
    https://cert-portal.siemens.com/productcert/pdf/s… x_refsource_CONFIRM
    https://www.intel.com/content/www/us/en/security-… x_refsource_CONFIRM
    https://tools.cisco.com/security/center/content/C… vendor-advisoryx_refsource_CISCO
    http://www.openwall.com/lists/oss-security/2021/12/15/3 mailing-listx_refsource_MLIST
    https://cert-portal.siemens.com/productcert/pdf/s… x_refsource_CONFIRM
    https://www.debian.org/security/2021/dsa-5022 vendor-advisoryx_refsource_DEBIAN
    http://www.openwall.com/lists/oss-security/2021/12/18/1 mailing-listx_refsource_MLIST
    https://cert-portal.siemens.com/productcert/pdf/s… x_refsource_CONFIRM
    https://cert-portal.siemens.com/productcert/pdf/s… x_refsource_CONFIRM
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisoryx_refsource_FEDORA
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisoryx_refsource_FEDORA
    https://www.oracle.com/security-alerts/cpujan2022.html x_refsource_MISC
    https://www.oracle.com/security-alerts/cpuapr2022.html x_refsource_MISC
    https://www.oracle.com/security-alerts/cpujul2022.html x_refsource_MISC
    https://security.gentoo.org/glsa/202310-16
    https://www.cisa.gov/known-exploited-vulnerabilit… government-resource
    Impacted products
    Vendor Product Version
    Apache Software Foundation Apache Log4j Affected: Apache Log4j2 , < 2.16.0 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:32:13.624Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cve.org/CVERecord?id=CVE-2021-44228"
              },
              {
                "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://logging.apache.org/log4j/2.x/security.html"
              },
              {
                "name": "VU#930724",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "https://www.kb.cert.org/vuls/id/930724"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
              },
              {
                "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_CISCO",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
              },
              {
                "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
              },
              {
                "name": "DSA-5022",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_DEBIAN",
                  "x_transferred"
                ],
                "url": "https://www.debian.org/security/2021/dsa-5022"
              },
              {
                "name": "[oss-security] 20211218 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/18/1"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
              },
              {
                "name": "FEDORA-2021-5c9d12a93e",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_FEDORA",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/EOKPQGV24RRBBI4TBZUDQMM4MEH7MXCY/"
              },
              {
                "name": "FEDORA-2021-abbe24e41c",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_FEDORA",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/SIG7FZULMNK2XF6FZRU4VWYDQXNMUGAJ/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujan2022.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202310-16"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "CHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-45046",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-04T19:31:22.638704Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2023-05-01",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-45046"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:25:22.768Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-45046"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2023-05-01T00:00:00.000Z",
                "value": "CVE-2021-45046 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Apache Log4j",
              "vendor": "Apache Software Foundation",
              "versions": [
                {
                  "lessThan": "2.16.0",
                  "status": "affected",
                  "version": "Apache Log4j2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "It was found that the fix to address CVE-2021-44228 in Apache Log4j 2.15.0 was incomplete in certain non-default configurations. This could allows attackers with control over Thread Context Map (MDC) input data when the logging configuration uses a non-default Pattern Layout with either a Context Lookup (for example, $${ctx:loginId}) or a Thread Context Map pattern (%X, %mdc, or %MDC) to craft malicious input data using a JNDI Lookup pattern resulting in an information leak and remote code execution in some environments and local code execution in all environments. Log4j 2.16.0 (Java 8) and 2.12.2 (Java 7) fix this issue by removing support for message lookup patterns and disabling JNDI functionality by default."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "other": "moderate (CVSS: 3.7 AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L)"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-917",
                  "description": "CWE-917 Improper Neutralization of Special Elements used in an Expression Language Statement (\u0027Expression Language Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-26T06:06:18.017Z",
            "orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
            "shortName": "apache"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cve.org/CVERecord?id=CVE-2021-44228"
            },
            {
              "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://logging.apache.org/log4j/2.x/security.html"
            },
            {
              "name": "VU#930724",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "https://www.kb.cert.org/vuls/id/930724"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
            },
            {
              "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
              "tags": [
                "vendor-advisory",
                "x_refsource_CISCO"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
            },
            {
              "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
            },
            {
              "name": "DSA-5022",
              "tags": [
                "vendor-advisory",
                "x_refsource_DEBIAN"
              ],
              "url": "https://www.debian.org/security/2021/dsa-5022"
            },
            {
              "name": "[oss-security] 20211218 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/18/1"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
            },
            {
              "name": "FEDORA-2021-5c9d12a93e",
              "tags": [
                "vendor-advisory",
                "x_refsource_FEDORA"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/EOKPQGV24RRBBI4TBZUDQMM4MEH7MXCY/"
            },
            {
              "name": "FEDORA-2021-abbe24e41c",
              "tags": [
                "vendor-advisory",
                "x_refsource_FEDORA"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/SIG7FZULMNK2XF6FZRU4VWYDQXNMUGAJ/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpujan2022.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            },
            {
              "url": "https://security.gentoo.org/glsa/202310-16"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "security@apache.org",
              "ID": "CVE-2021-45046",
              "STATE": "PUBLIC",
              "TITLE": "Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Apache Log4j",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "Apache Log4j2",
                                "version_value": "2.16.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Apache Software Foundation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "It was found that the fix to address CVE-2021-44228 in Apache Log4j 2.15.0 was incomplete in certain non-default configurations. This could allows attackers with control over Thread Context Map (MDC) input data when the logging configuration uses a non-default Pattern Layout with either a Context Lookup (for example, $${ctx:loginId}) or a Thread Context Map pattern (%X, %mdc, or %MDC) to craft malicious input data using a JNDI Lookup pattern resulting in an information leak and remote code execution in some environments and local code execution in all environments. Log4j 2.16.0 (Java 8) and 2.12.2 (Java 7) fix this issue by removing support for message lookup patterns and disabling JNDI functionality by default."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": [
              {
                "other": "moderate (CVSS: 3.7 AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L)"
              }
            ],
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-917 Improper Neutralization of Special Elements used in an Expression Language Statement (\u0027Expression Language Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html",
                  "refsource": "CONFIRM",
                  "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
                },
                {
                  "name": "https://www.cve.org/CVERecord?id=CVE-2021-44228",
                  "refsource": "MISC",
                  "url": "https://www.cve.org/CVERecord?id=CVE-2021-44228"
                },
                {
                  "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
                },
                {
                  "name": "https://logging.apache.org/log4j/2.x/security.html",
                  "refsource": "CONFIRM",
                  "url": "https://logging.apache.org/log4j/2.x/security.html"
                },
                {
                  "name": "VU#930724",
                  "refsource": "CERT-VN",
                  "url": "https://www.kb.cert.org/vuls/id/930724"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
                },
                {
                  "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html",
                  "refsource": "CONFIRM",
                  "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
                },
                {
                  "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
                  "refsource": "CISCO",
                  "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
                },
                {
                  "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
                },
                {
                  "name": "DSA-5022",
                  "refsource": "DEBIAN",
                  "url": "https://www.debian.org/security/2021/dsa-5022"
                },
                {
                  "name": "[oss-security] 20211218 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/12/18/1"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
                },
                {
                  "name": "FEDORA-2021-5c9d12a93e",
                  "refsource": "FEDORA",
                  "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/EOKPQGV24RRBBI4TBZUDQMM4MEH7MXCY/"
                },
                {
                  "name": "FEDORA-2021-abbe24e41c",
                  "refsource": "FEDORA",
                  "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SIG7FZULMNK2XF6FZRU4VWYDQXNMUGAJ/"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpujan2022.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpujan2022.html"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpuapr2022.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpujul2022.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
        "assignerShortName": "apache",
        "cveId": "CVE-2021-45046",
        "datePublished": "2021-12-14T16:55:09.000Z",
        "dateReserved": "2021-12-14T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:25:22.768Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-44228 (GCVE-0-2021-44228)

    Vulnerability from nvd – Published: 2021-12-10 00:00 – Updated: 2025-10-21 23:25
    Title
    Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints
    Summary
    Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects.
    SSVC
    Exploitation: active Automatable: yes Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2025-02-04 14:25 UTC
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    • CWE-400 - Uncontrolled Resource Consumption
    • CWE-20 - Improper Input Validation
    Assigner
    apache CNA under the mitre root
    CNA scorecard B 76/100 over 1271 records in the last 180 days details
    References
    URL Tags
    https://logging.apache.org/log4j/2.x/security.html
    http://www.openwall.com/lists/oss-security/2021/12/10/1 mailing-list
    http://www.openwall.com/lists/oss-security/2021/12/10/2 mailing-list
    https://tools.cisco.com/security/center/content/C… vendor-advisory
    http://www.openwall.com/lists/oss-security/2021/12/10/3 mailing-list
    https://security.netapp.com/advisory/ntap-2021121…
    http://packetstormsecurity.com/files/165225/Apach…
    https://psirt.global.sonicwall.com/vuln-detail/SN…
    https://www.oracle.com/security-alerts/alert-cve-…
    https://www.debian.org/security/2021/dsa-5020 vendor-advisory
    https://lists.debian.org/debian-lts-announce/2021… mailing-list
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://msrc-blog.microsoft.com/2021/12/11/micros… vendor-advisory
    http://www.openwall.com/lists/oss-security/2021/12/13/2 mailing-list
    http://www.openwall.com/lists/oss-security/2021/12/13/1 mailing-list
    http://www.openwall.com/lists/oss-security/2021/12/14/4 mailing-list
    https://www.kb.cert.org/vuls/id/930724 third-party-advisory
    https://twitter.com/kurtseifried/status/146934553…
    https://cert-portal.siemens.com/productcert/pdf/s…
    http://packetstormsecurity.com/files/165260/VMwar…
    http://packetstormsecurity.com/files/165270/Apach…
    http://packetstormsecurity.com/files/165261/Apach…
    https://www.intel.com/content/www/us/en/security-…
    http://www.openwall.com/lists/oss-security/2021/12/15/3 mailing-list
    http://packetstormsecurity.com/files/165282/Log4j…
    http://packetstormsecurity.com/files/165281/Log4j…
    http://packetstormsecurity.com/files/165307/Log4j…
    http://packetstormsecurity.com/files/165311/log4j…
    http://packetstormsecurity.com/files/165306/L4sh-…
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    http://packetstormsecurity.com/files/165371/VMwar…
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://www.oracle.com/security-alerts/cpujan2022.html
    http://packetstormsecurity.com/files/165532/Log4S…
    https://github.com/cisagov/log4j-affected-db/blob…
    http://packetstormsecurity.com/files/165642/VMwar…
    http://packetstormsecurity.com/files/165673/UniFi…
    http://seclists.org/fulldisclosure/2022/Mar/23 mailing-list
    https://www.bentley.com/en/common-vulnerability-e…
    https://github.com/cisagov/log4j-affected-db
    https://support.apple.com/kb/HT213189
    https://www.oracle.com/security-alerts/cpuapr2022.html
    https://github.com/nu11secur1ty/CVE-mitre/tree/ma…
    https://www.nu11secur1ty.com/2021/12/cve-2021-442…
    http://seclists.org/fulldisclosure/2022/Jul/11 mailing-list
    http://packetstormsecurity.com/files/167794/Open-…
    http://packetstormsecurity.com/files/167917/Mobil…
    http://seclists.org/fulldisclosure/2022/Dec/2 mailing-list
    http://packetstormsecurity.com/files/171626/AD-Ma…
    https://www.cisa.gov/known-exploited-vulnerabilit… government-resource
    Impacted products
    Vendor Product Version
    Apache Software Foundation Apache Log4j2 Affected: 2.0-beta9 , < log4j-core* (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:17:24.696Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://logging.apache.org/log4j/2.x/security.html"
              },
              {
                "name": "[oss-security] 20211210 CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/10/1"
              },
              {
                "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/10/2"
              },
              {
                "name": "20211210 Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
              },
              {
                "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/10/3"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20211210-0007/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165225/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
              },
              {
                "name": "DSA-5020",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.debian.org/security/2021/dsa-5020"
              },
              {
                "name": "[debian-lts-announce] 20211212 [SECURITY] [DLA 2842-1] apache-log4j2 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2021/12/msg00007.html"
              },
              {
                "name": "FEDORA-2021-f0f501d01f",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VU57UJDCFIASIO35GC55JMKSRXJMCDFM/"
              },
              {
                "name": "Microsoft\u2019s Response to CVE-2021-44228 Apache Log4j 2",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://msrc-blog.microsoft.com/2021/12/11/microsofts-response-to-cve-2021-44228-apache-log4j2/"
              },
              {
                "name": "[oss-security] 20211213 Re: CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/13/2"
              },
              {
                "name": "[oss-security] 20211213 CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/13/1"
              },
              {
                "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
              },
              {
                "name": "20211210 A Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
              },
              {
                "name": "VU#930724",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://www.kb.cert.org/vuls/id/930724"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://twitter.com/kurtseifried/status/1469345530182455296"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165260/VMware-Security-Advisory-2021-0028.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165270/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165261/Apache-Log4j2-2.14.1-Information-Disclosure.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
              },
              {
                "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
              },
              {
                "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165282/Log4j-Payload-Generator.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165281/Log4j2-Log4Shell-Regexes.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165307/Log4j-Remote-Code-Execution-Word-Bypassing.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165311/log4j-scan-Extensive-Scanner.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165306/L4sh-Log4j-Remote-Code-Execution.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
              },
              {
                "name": "FEDORA-2021-66d6c484f3",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/M5CSVUNV4HWZZXGOKNSK6L7RPM7BOKIB/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165371/VMware-Security-Advisory-2021-0028.4.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujan2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165532/Log4Shell-HTTP-Header-Injection.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/cisagov/log4j-affected-db/blob/develop/SOFTWARE-LIST.md"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165642/VMware-vCenter-Server-Unauthenticated-Log4Shell-JNDI-Injection-Remote-Code-Execution.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165673/UniFi-Network-Application-Unauthenticated-Log4Shell-Remote-Code-Execution.html"
              },
              {
                "name": "20220314 APPLE-SA-2022-03-14-7 Xcode 13.3",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/Mar/23"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0001"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/cisagov/log4j-affected-db"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.apple.com/kb/HT213189"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/nu11secur1ty/CVE-mitre/tree/main/CVE-2021-44228"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nu11secur1ty.com/2021/12/cve-2021-44228.html"
              },
              {
                "name": "20220721 Open-Xchange Security Advisory 2022-07-21",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/Jul/11"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/167794/Open-Xchange-App-Suite-7.10.x-Cross-Site-Scripting-Command-Injection.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/167917/MobileIron-Log4Shell-Remote-Command-Execution.html"
              },
              {
                "name": "20221208 Intel Data Center Manager \u003c= 5.1 Local Privileges Escalation",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/Dec/2"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/171626/AD-Manager-Plus-7122-Remote-Code-Execution.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 10,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "CHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-44228",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-04T14:25:34.416117Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2021-12-10",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-44228"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:25:23.121Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-44228"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2021-12-10T00:00:00.000Z",
                "value": "CVE-2021-44228 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Apache Log4j2",
              "vendor": "Apache Software Foundation",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "2.3.1",
                      "status": "unaffected"
                    },
                    {
                      "at": "2.4",
                      "status": "affected"
                    },
                    {
                      "at": "2.12.2",
                      "status": "unaffected"
                    },
                    {
                      "at": "2.13.0",
                      "status": "affected"
                    },
                    {
                      "at": "2.15.0",
                      "status": "unaffected"
                    }
                  ],
                  "lessThan": "log4j-core*",
                  "status": "affected",
                  "version": "2.0-beta9",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "This issue was discovered by Chen Zhaojun of Alibaba Cloud Security Team."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "other": "critical"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502 Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400 Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-04-03T00:00:00.000Z",
            "orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
            "shortName": "apache"
          },
          "references": [
            {
              "url": "https://logging.apache.org/log4j/2.x/security.html"
            },
            {
              "name": "[oss-security] 20211210 CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/10/1"
            },
            {
              "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/10/2"
            },
            {
              "name": "20211210 Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
            },
            {
              "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/10/3"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20211210-0007/"
            },
            {
              "url": "http://packetstormsecurity.com/files/165225/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
            },
            {
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
            },
            {
              "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
            },
            {
              "name": "DSA-5020",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.debian.org/security/2021/dsa-5020"
            },
            {
              "name": "[debian-lts-announce] 20211212 [SECURITY] [DLA 2842-1] apache-log4j2 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2021/12/msg00007.html"
            },
            {
              "name": "FEDORA-2021-f0f501d01f",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VU57UJDCFIASIO35GC55JMKSRXJMCDFM/"
            },
            {
              "name": "Microsoft\u2019s Response to CVE-2021-44228 Apache Log4j 2",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://msrc-blog.microsoft.com/2021/12/11/microsofts-response-to-cve-2021-44228-apache-log4j2/"
            },
            {
              "name": "[oss-security] 20211213 Re: CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/13/2"
            },
            {
              "name": "[oss-security] 20211213 CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/13/1"
            },
            {
              "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
            },
            {
              "name": "20211210 A Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
            },
            {
              "name": "VU#930724",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.kb.cert.org/vuls/id/930724"
            },
            {
              "url": "https://twitter.com/kurtseifried/status/1469345530182455296"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
            },
            {
              "url": "http://packetstormsecurity.com/files/165260/VMware-Security-Advisory-2021-0028.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165270/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165261/Apache-Log4j2-2.14.1-Information-Disclosure.html"
            },
            {
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
            },
            {
              "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
            },
            {
              "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
            },
            {
              "url": "http://packetstormsecurity.com/files/165282/Log4j-Payload-Generator.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165281/Log4j2-Log4Shell-Regexes.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165307/Log4j-Remote-Code-Execution-Word-Bypassing.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165311/log4j-scan-Extensive-Scanner.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165306/L4sh-Log4j-Remote-Code-Execution.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
            },
            {
              "name": "FEDORA-2021-66d6c484f3",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/M5CSVUNV4HWZZXGOKNSK6L7RPM7BOKIB/"
            },
            {
              "url": "http://packetstormsecurity.com/files/165371/VMware-Security-Advisory-2021-0028.4.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpujan2022.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165532/Log4Shell-HTTP-Header-Injection.html"
            },
            {
              "url": "https://github.com/cisagov/log4j-affected-db/blob/develop/SOFTWARE-LIST.md"
            },
            {
              "url": "http://packetstormsecurity.com/files/165642/VMware-vCenter-Server-Unauthenticated-Log4Shell-JNDI-Injection-Remote-Code-Execution.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165673/UniFi-Network-Application-Unauthenticated-Log4Shell-Remote-Code-Execution.html"
            },
            {
              "name": "20220314 APPLE-SA-2022-03-14-7 Xcode 13.3",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/Mar/23"
            },
            {
              "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0001"
            },
            {
              "url": "https://github.com/cisagov/log4j-affected-db"
            },
            {
              "url": "https://support.apple.com/kb/HT213189"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "url": "https://github.com/nu11secur1ty/CVE-mitre/tree/main/CVE-2021-44228"
            },
            {
              "url": "https://www.nu11secur1ty.com/2021/12/cve-2021-44228.html"
            },
            {
              "name": "20220721 Open-Xchange Security Advisory 2022-07-21",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/Jul/11"
            },
            {
              "url": "http://packetstormsecurity.com/files/167794/Open-Xchange-App-Suite-7.10.x-Cross-Site-Scripting-Command-Injection.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/167917/MobileIron-Log4Shell-Remote-Command-Execution.html"
            },
            {
              "name": "20221208 Intel Data Center Manager \u003c= 5.1 Local Privileges Escalation",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/Dec/2"
            },
            {
              "url": "http://packetstormsecurity.com/files/171626/AD-Manager-Plus-7122-Remote-Code-Execution.html"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
        "assignerShortName": "apache",
        "cveId": "CVE-2021-44228",
        "datePublished": "2021-12-10T00:00:00.000Z",
        "dateReserved": "2021-11-26T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:25:23.121Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-10933 (GCVE-0-2019-10933)

    Vulnerability from nvd – Published: 2019-07-11 21:17 – Updated: 2024-08-04 22:40
    VLAI
    Summary
    A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions <= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions < v5.50), Spectrum Power 7 (Corporate User Interface) (All versions <= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user does not need to be logged into the web interface in order for the exploitation to succeed.At the stage of publishing this security advisory no public exploitation is known.
    Severity
    No CVSS data available.
    CWE
    • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:40:15.253Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-747162.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Spectrum Power 3 (Corporate User Interface)",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c= v3.11"
                }
              ]
            },
            {
              "product": "Spectrum Power 4 (Corporate User Interface)",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version v4.75"
                }
              ]
            },
            {
              "product": "Spectrum Power 5 (Corporate User Interface)",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c v5.50"
                }
              ]
            },
            {
              "product": "Spectrum Power 7 (Corporate User Interface)",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c= v2.20"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions \u003c= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions \u003c v5.50), Spectrum Power 7 (Corporate User Interface) (All versions \u003c= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user does not need to be logged into the web interface in order for the exploitation to succeed.At the stage of publishing this security advisory no public exploitation is known."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-80",
                  "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-13T18:55:57.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-747162.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2019-10933",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Spectrum Power 3 (Corporate User Interface)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c= v3.11"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Spectrum Power 4 (Corporate User Interface)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version v4.75"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Spectrum Power 5 (Corporate User Interface)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c v5.50"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Spectrum Power 7 (Corporate User Interface)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c= v2.20"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens AG"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions \u003c= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions \u003c v5.50), Spectrum Power 7 (Corporate User Interface) (All versions \u003c= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user does not need to be logged into the web interface in order for the exploitation to succeed.At the stage of publishing this security advisory no public exploitation is known."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-747162.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-747162.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-10933",
        "datePublished": "2019-07-11T21:17:47.000Z",
        "dateReserved": "2019-04-08T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:40:15.253Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-109619 (GCVE-0-2026-109619)

    Vulnerability from cvelistv5 – Published: 2026-10-21 13:54 – Updated: 2026-11-18 18:32
    VLAI CISA Shadowserver Previdian
    Title
    RCE via stale global state
    Summary
    PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE).
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2026-10-21 00:00 UTC
    CWE
    • CWE-416 - Use after free
    • CWE-755 - Improper Handling of Exceptional Conditions
    • CWE-824 - Access of uninitialized pointer
    • CWE-1325 - Improperly controlled sequential memory allocation
    • CWE-1419 - Incorrect Initialization of Resource
    Assigner
    php CNA under the mitre root
    CNA scorecard B 82/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    PHP Group PHP Affected: 8.2.* , < 8.2.35 (semver)
    Affected: 8.3.* , < 8.3.36 (semver)
    Affected: 8.4.* , < 8.4.27 (semver)
    Affected: 8.5.* , < 8.5.12 (semver)
    Create a notification for this product.
    Siemens AMIS TS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens AX4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX - S Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Building X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens CADRA Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Call stations Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Capital Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Chargesight Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Cloud IC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Devices Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect Insights Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X200 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X300 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X500 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens cRSP Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Depotfinity Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Essentials Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR2 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo Optic Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC5 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC7 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens DFMExpress Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V2.0SP9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V3.1SP1 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Management System Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted RTLS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted Space Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox H60 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Rapid Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Local Monitoring bt-monitoring-vm Affected: 0 , < V20261103 (custom)
    Create a notification for this product.
    Siemens Navigator E&S Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Unaffected: 0 , < * (custom)
    Create a notification for this product.

    50 of 110 products shown. All of them on the page of CVE-2026-109619.

    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-109619",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-21T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2026-10-26",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:47.838Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://www.wiz.io/blog/php2shell-php-rce"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://php2shell.delftintellab.com/"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2026-10-26T00:00:00.000Z",
                "value": "CVE-2026-109619 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-10-23T14:07:57.152Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/7"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/17"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/23"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/2"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/14"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/15"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/19"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/20"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/4"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "AMIS TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "AX4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX - S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Building X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "CADRA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Call stations",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Capital",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Chargesight",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Cloud IC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Devices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect Insights",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X200",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X300",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X500",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "cRSP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Depotfinity",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo Optic",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DFMExpress",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V2.0SP9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V3.1SP1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Management System",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted RTLS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted Space",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox H60",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Rapid",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Local Monitoring bt-monitoring-vm",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V20261103",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Navigator E\u0026S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PACE-Design",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard \u0026 Standard Plus",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Pathway to Learning Engineering",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Polarion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "QuadView",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D Configuration Backend",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flomaster",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flux",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Simlab",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sinteso FS20 EN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SiPass integrated",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPORT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Intrusion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Video",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power TG",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Supply Chain Suite",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Product Cost Management",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Share",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Visualization",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Tecnomatix Plant Simulation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TestWay",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Valor NPI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Verischarge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloudHeliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm panels",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm systems and audio matrices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Workplace Experience",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV676-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "FW6.9.22-3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV776-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xcargo",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition IC Packaging",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Layout Browser",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-18T18:32:28.496Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "php-src",
              "product": "PHP",
              "vendor": "PHP Group",
              "versions": [
                {
                  "lessThan": "8.2.35",
                  "status": "affected",
                  "version": "8.2.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.3.36",
                  "status": "affected",
                  "version": "8.3.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.4.27",
                  "status": "affected",
                  "version": "8.4.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.5.12",
                  "status": "affected",
                  "version": "8.5.*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Wiz"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "Ryan at Calif.io"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "OpenAI"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Arnaud Le Blanc"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Ilija Tovilo"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Jakub Zelenka"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Nora Dossche"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
                }
              ],
              "value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-234",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-234 Hijacking a privileged process"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416 Use after free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755 Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824 Access of uninitialized pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1325",
                  "description": "CWE-1325 Improperly controlled sequential memory allocation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1419",
                  "description": "CWE-1419 Incorrect Initialization of Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T13:54:43.866Z",
            "orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
            "shortName": "php"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://github.com/php/php-src/security/advisories/GHSA-6wmf-4rv5-p3rp"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "RCE via stale global state",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Check the GitHub Security Advisory for mitigation strategies."
                }
              ],
              "value": "Check the GitHub Security Advisory for mitigation strategies."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
        "assignerShortName": "php",
        "cveId": "CVE-2026-109619",
        "datePublished": "2026-10-21T13:54:43.866Z",
        "dateReserved": "2026-10-12T21:04:00.504Z",
        "dateUpdated": "2026-11-18T18:32:28.496Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-109618 (GCVE-0-2026-109618)

    Vulnerability from cvelistv5 – Published: 2026-10-21 13:48 – Updated: 2026-11-18 18:32
    VLAI CISA Shadowserver Previdian
    Title
    RCE via OOM corruption
    Summary
    PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2026-10-21 00:00 UTC
    CWE
    • CWE-416 - Use after free
    • CWE-755 - Improper Handling of Exceptional Conditions
    • CWE-824 - Access of uninitialized pointer
    • CWE-1325 - Improperly controlled sequential memory allocation
    • CWE-1419 - Incorrect Initialization of Resource
    Assigner
    php CNA under the mitre root
    CNA scorecard B 82/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    PHP Group PHP Affected: 8.2.* , < 8.2.35 (semver)
    Affected: 8.3.* , < 8.3.36 (semver)
    Affected: 8.4.* , < 8.4.27 (semver)
    Affected: 8.5.* , < 8.5.12 (semver)
    Create a notification for this product.
    Siemens AMIS TS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens AX4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX - S Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Building X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens CADRA Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Call stations Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Capital Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Chargesight Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Cloud IC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Devices Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect Insights Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X200 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X300 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X500 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens cRSP Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Depotfinity Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Essentials Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR2 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo Optic Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC5 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC7 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens DFMExpress Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V2.0SP9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V3.1SP1 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Management System Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted RTLS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted Space Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox H60 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Rapid Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Local Monitoring bt-monitoring-vm Affected: 0 , < V20261103 (custom)
    Create a notification for this product.
    Siemens Navigator E&S Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Unaffected: 0 , < * (custom)
    Create a notification for this product.

    50 of 109 products shown. All of them on the page of CVE-2026-109618.

    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-109618",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-21T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2026-10-26",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:46.712Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://www.wiz.io/blog/php2shell-php-rce"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://php2shell.delftintellab.com"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2026-10-26T00:00:00.000Z",
                "value": "CVE-2026-109618 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-15T00:15:58.835Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/5"
              },
              {
                "url": "http://seclists.org/fulldisclosure/2026/Oct/51"
              },
              {
                "url": "https://github.com/rapid7/metasploit-framework/pull/22139"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "AMIS TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "AX4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX - S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Building X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "CADRA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Call stations",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Capital",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Chargesight",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Cloud IC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Devices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect Insights",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X200",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X300",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X500",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "cRSP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Depotfinity",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo Optic",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DFMExpress",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V2.0SP9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V3.1SP1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Management System",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted RTLS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted Space",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox H60",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Rapid",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Local Monitoring bt-monitoring-vm",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V20261103",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Navigator E\u0026S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PACE-Design",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard \u0026 Standard Plus",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Pathway to Learning Engineering",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Polarion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "QuadView",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D Configuration Backend",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flomaster",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flux",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Simlab",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sinteso FS20 EN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SiPass integrated",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPORT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Intrusion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Video",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power TG",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Supply Chain Suite",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Product Cost Management",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Share",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Visualization",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Tecnomatix Plant Simulation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TestWay",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Valor NPI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Verischarge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloudHeliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm panels",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm systems and audio matrices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Workplace Experience",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV676-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "FW6.9.22-3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV776-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xcargo",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition IC Packaging",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Layout Browser",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-18T18:32:27.150Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "php-src",
              "product": "PHP",
              "vendor": "PHP Group",
              "versions": [
                {
                  "lessThan": "8.2.35",
                  "status": "affected",
                  "version": "8.2.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.3.36",
                  "status": "affected",
                  "version": "8.3.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.4.27",
                  "status": "affected",
                  "version": "8.4.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.5.12",
                  "status": "affected",
                  "version": "8.5.*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Ryan at Calif.io"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "Wiz"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Arnaud Le Blanc"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Ilija Tovilo"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Jakub Zelenka"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Nora Dossche"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).\u003cbr\u003e"
                }
              ],
              "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE)."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-234",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-234 Hijacking a privileged process"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416 Use after free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755 Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824 Access of uninitialized pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1325",
                  "description": "CWE-1325 Improperly controlled sequential memory allocation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1419",
                  "description": "CWE-1419 Incorrect Initialization of Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T13:48:34.845Z",
            "orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
            "shortName": "php"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "RCE via OOM corruption",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Check the GitHub Security Advisory for mitigation strategies."
                }
              ],
              "value": "Check the GitHub Security Advisory for mitigation strategies."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
        "assignerShortName": "php",
        "cveId": "CVE-2026-109618",
        "datePublished": "2026-10-21T13:48:34.845Z",
        "dateReserved": "2026-10-12T21:03:58.117Z",
        "dateUpdated": "2026-11-18T18:32:27.150Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-29119 (GCVE-0-2024-29119)

    Vulnerability from cvelistv5 – Published: 2024-11-12 12:49 – Updated: 2024-11-12 14:38
    VLAI
    Summary
    A vulnerability has been identified in Spectrum Power 7 (All versions < V24Q3). The affected product contains several root-owned SUID binaries that could allow an authenticated local attacker to escalate privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2024-11-12 14:36 UTC
    CWE
    • CWE-266 - Incorrect Privilege Assignment
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens Spectrum Power 7 Affected: 0 , < V24Q3 (custom)
    Create a notification for this product.
    siemens spectrum_power_7 Affected: 0 , < v24q3 (custom)
        cpe:2.3:a:siemens:spectrum_power_7:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:spectrum_power_7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "spectrum_power_7",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "v24q3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-29119",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-12T14:36:34.804870Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-12T14:38:15.692Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Spectrum Power 7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V24Q3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V24Q3). The affected product contains several root-owned SUID binaries that could allow an authenticated local attacker to escalate privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "CWE-266: Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-12T12:49:27.011Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-616032.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-29119",
        "datePublished": "2024-11-12T12:49:27.011Z",
        "dateReserved": "2024-03-15T19:27:44.950Z",
        "dateUpdated": "2024-11-12T14:38:15.692Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-44120 (GCVE-0-2023-44120)

    Vulnerability from cvelistv5 – Published: 2024-01-09 09:59 – Updated: 2024-11-14 15:24
    VLAI
    Summary
    A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q4). The affected product's sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2024-01-22 20:23 UTC
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens Spectrum Power 7 Affected: All versions < V23Q4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T19:59:51.225Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-44120",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-22T20:23:10.458980Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-14T15:24:09.445Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Spectrum Power 7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V23Q4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q4). The affected product\u0027s sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-09T09:59:44.755Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-786191.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-44120",
        "datePublished": "2024-01-09T09:59:44.755Z",
        "dateReserved": "2023-09-25T10:24:56.157Z",
        "dateUpdated": "2024-11-14T15:24:09.445Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38557 (GCVE-0-2023-38557)

    Vulnerability from cvelistv5 – Published: 2023-09-14 10:39 – Updated: 2025-02-27 20:50
    VLAI
    Summary
    A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q3). The affected product assigns improper access rights to the update script. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2025-02-26 21:51 UTC
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens Spectrum Power 7 Affected: All versions < V23Q3
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:46:56.237Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-357182.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-38557",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-26T21:51:13.615641Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-27T20:50:26.366Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Spectrum Power 7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V23Q3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Spectrum Power 7 (All versions \u003c V23Q3). The affected product assigns improper access rights to the update script. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-09-14T10:39:28.689Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-357182.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-38557",
        "datePublished": "2023-09-14T10:39:28.689Z",
        "dateReserved": "2023-07-20T08:17:26.143Z",
        "dateUpdated": "2025-02-27T20:50:26.366Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26476 (GCVE-0-2022-26476)

    Vulnerability from cvelistv5 – Published: 2022-06-14 09:21 – Updated: 2024-08-03 05:03
    VLAI
    Summary
    A vulnerability has been identified in Spectrum Power 4 (All versions using Shared HIS), Spectrum Power 7 (All versions using Shared HIS), Spectrum Power MGMS (All versions using Shared HIS). An unauthenticated attacker could log into the component Shared HIS used in Spectrum Power systems by using an account with default credentials. A successful exploitation could allow the attacker to access the component Shared HIS with administrative privileges.
    Severity
    No CVSS data available.
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Siemens Spectrum Power 4 Affected: All versions using Shared HIS
    Create a notification for this product.
    Siemens Spectrum Power 7 Affected: All versions using Shared HIS
    Create a notification for this product.
    Siemens Spectrum Power MGMS Affected: All versions using Shared HIS
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:03:32.863Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-388239.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Spectrum Power 4",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions using Shared HIS"
                }
              ]
            },
            {
              "product": "Spectrum Power 7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions using Shared HIS"
                }
              ]
            },
            {
              "product": "Spectrum Power MGMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions using Shared HIS"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Spectrum Power 4 (All versions using Shared HIS), Spectrum Power 7 (All versions using Shared HIS), Spectrum Power MGMS (All versions using Shared HIS). An unauthenticated attacker could log into the component Shared HIS used in Spectrum Power systems by using an account with default credentials. A successful exploitation could allow the attacker to access the component Shared HIS with administrative privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798: Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-14T09:21:38.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-388239.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2022-26476",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Spectrum Power 4",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions using Shared HIS"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Spectrum Power 7",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions using Shared HIS"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Spectrum Power MGMS",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions using Shared HIS"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Spectrum Power 4 (All versions using Shared HIS), Spectrum Power 7 (All versions using Shared HIS), Spectrum Power MGMS (All versions using Shared HIS). An unauthenticated attacker could log into the component Shared HIS used in Spectrum Power systems by using an account with default credentials. A successful exploitation could allow the attacker to access the component Shared HIS with administrative privileges."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-798: Use of Hard-coded Credentials"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-388239.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-388239.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2022-26476",
        "datePublished": "2022-06-14T09:21:38.000Z",
        "dateReserved": "2022-03-04T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:03:32.863Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-45046 (GCVE-0-2021-45046)

    Vulnerability from cvelistv5 – Published: 2021-12-14 16:55 – Updated: 2025-10-21 23:25
    VLAI CISA Previdian
    Title
    Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack
    Summary
    It was found that the fix to address CVE-2021-44228 in Apache Log4j 2.15.0 was incomplete in certain non-default configurations. This could allows attackers with control over Thread Context Map (MDC) input data when the logging configuration uses a non-default Pattern Layout with either a Context Lookup (for example, $${ctx:loginId}) or a Thread Context Map pattern (%X, %mdc, or %MDC) to craft malicious input data using a JNDI Lookup pattern resulting in an information leak and remote code execution in some environments and local code execution in all environments. Log4j 2.16.0 (Java 8) and 2.12.2 (Java 7) fix this issue by removing support for message lookup patterns and disabling JNDI functionality by default.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2025-02-04 19:31 UTC
    CWE
    • CWE-917 - Improper Neutralization of Special Elements used in an Expression Language Statement ('Expression Language Injection')
    Assigner
    apache CNA under the mitre root
    CNA scorecard B 76/100 over 1271 records in the last 180 days details
    References
    URL Tags
    https://psirt.global.sonicwall.com/vuln-detail/SN… x_refsource_CONFIRM
    https://www.oracle.com/security-alerts/alert-cve-… x_refsource_CONFIRM
    https://www.cve.org/CVERecord?id=CVE-2021-44228 x_refsource_MISC
    http://www.openwall.com/lists/oss-security/2021/12/14/4 mailing-listx_refsource_MLIST
    https://logging.apache.org/log4j/2.x/security.html x_refsource_CONFIRM
    https://www.kb.cert.org/vuls/id/930724 third-party-advisoryx_refsource_CERT-VN
    https://cert-portal.siemens.com/productcert/pdf/s… x_refsource_CONFIRM
    https://www.intel.com/content/www/us/en/security-… x_refsource_CONFIRM
    https://tools.cisco.com/security/center/content/C… vendor-advisoryx_refsource_CISCO
    http://www.openwall.com/lists/oss-security/2021/12/15/3 mailing-listx_refsource_MLIST
    https://cert-portal.siemens.com/productcert/pdf/s… x_refsource_CONFIRM
    https://www.debian.org/security/2021/dsa-5022 vendor-advisoryx_refsource_DEBIAN
    http://www.openwall.com/lists/oss-security/2021/12/18/1 mailing-listx_refsource_MLIST
    https://cert-portal.siemens.com/productcert/pdf/s… x_refsource_CONFIRM
    https://cert-portal.siemens.com/productcert/pdf/s… x_refsource_CONFIRM
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisoryx_refsource_FEDORA
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisoryx_refsource_FEDORA
    https://www.oracle.com/security-alerts/cpujan2022.html x_refsource_MISC
    https://www.oracle.com/security-alerts/cpuapr2022.html x_refsource_MISC
    https://www.oracle.com/security-alerts/cpujul2022.html x_refsource_MISC
    https://security.gentoo.org/glsa/202310-16
    https://www.cisa.gov/known-exploited-vulnerabilit… government-resource
    Impacted products
    Vendor Product Version
    Apache Software Foundation Apache Log4j Affected: Apache Log4j2 , < 2.16.0 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:32:13.624Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cve.org/CVERecord?id=CVE-2021-44228"
              },
              {
                "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://logging.apache.org/log4j/2.x/security.html"
              },
              {
                "name": "VU#930724",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "https://www.kb.cert.org/vuls/id/930724"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
              },
              {
                "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_CISCO",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
              },
              {
                "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
              },
              {
                "name": "DSA-5022",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_DEBIAN",
                  "x_transferred"
                ],
                "url": "https://www.debian.org/security/2021/dsa-5022"
              },
              {
                "name": "[oss-security] 20211218 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                "tags": [
                  "mailing-list",
                  "x_refsource_MLIST",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/18/1"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
              },
              {
                "name": "FEDORA-2021-5c9d12a93e",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_FEDORA",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/EOKPQGV24RRBBI4TBZUDQMM4MEH7MXCY/"
              },
              {
                "name": "FEDORA-2021-abbe24e41c",
                "tags": [
                  "vendor-advisory",
                  "x_refsource_FEDORA",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/SIG7FZULMNK2XF6FZRU4VWYDQXNMUGAJ/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujan2022.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.gentoo.org/glsa/202310-16"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "CHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-45046",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-04T19:31:22.638704Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2023-05-01",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-45046"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:25:22.768Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-45046"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2023-05-01T00:00:00.000Z",
                "value": "CVE-2021-45046 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Apache Log4j",
              "vendor": "Apache Software Foundation",
              "versions": [
                {
                  "lessThan": "2.16.0",
                  "status": "affected",
                  "version": "Apache Log4j2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "It was found that the fix to address CVE-2021-44228 in Apache Log4j 2.15.0 was incomplete in certain non-default configurations. This could allows attackers with control over Thread Context Map (MDC) input data when the logging configuration uses a non-default Pattern Layout with either a Context Lookup (for example, $${ctx:loginId}) or a Thread Context Map pattern (%X, %mdc, or %MDC) to craft malicious input data using a JNDI Lookup pattern resulting in an information leak and remote code execution in some environments and local code execution in all environments. Log4j 2.16.0 (Java 8) and 2.12.2 (Java 7) fix this issue by removing support for message lookup patterns and disabling JNDI functionality by default."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "other": "moderate (CVSS: 3.7 AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L)"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-917",
                  "description": "CWE-917 Improper Neutralization of Special Elements used in an Expression Language Statement (\u0027Expression Language Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-26T06:06:18.017Z",
            "orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
            "shortName": "apache"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cve.org/CVERecord?id=CVE-2021-44228"
            },
            {
              "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://logging.apache.org/log4j/2.x/security.html"
            },
            {
              "name": "VU#930724",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "https://www.kb.cert.org/vuls/id/930724"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
            },
            {
              "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
              "tags": [
                "vendor-advisory",
                "x_refsource_CISCO"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
            },
            {
              "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
            },
            {
              "name": "DSA-5022",
              "tags": [
                "vendor-advisory",
                "x_refsource_DEBIAN"
              ],
              "url": "https://www.debian.org/security/2021/dsa-5022"
            },
            {
              "name": "[oss-security] 20211218 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
              "tags": [
                "mailing-list",
                "x_refsource_MLIST"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/18/1"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
            },
            {
              "name": "FEDORA-2021-5c9d12a93e",
              "tags": [
                "vendor-advisory",
                "x_refsource_FEDORA"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/EOKPQGV24RRBBI4TBZUDQMM4MEH7MXCY/"
            },
            {
              "name": "FEDORA-2021-abbe24e41c",
              "tags": [
                "vendor-advisory",
                "x_refsource_FEDORA"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/SIG7FZULMNK2XF6FZRU4VWYDQXNMUGAJ/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpujan2022.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            },
            {
              "url": "https://security.gentoo.org/glsa/202310-16"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "security@apache.org",
              "ID": "CVE-2021-45046",
              "STATE": "PUBLIC",
              "TITLE": "Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Apache Log4j",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "Apache Log4j2",
                                "version_value": "2.16.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Apache Software Foundation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "It was found that the fix to address CVE-2021-44228 in Apache Log4j 2.15.0 was incomplete in certain non-default configurations. This could allows attackers with control over Thread Context Map (MDC) input data when the logging configuration uses a non-default Pattern Layout with either a Context Lookup (for example, $${ctx:loginId}) or a Thread Context Map pattern (%X, %mdc, or %MDC) to craft malicious input data using a JNDI Lookup pattern resulting in an information leak and remote code execution in some environments and local code execution in all environments. Log4j 2.16.0 (Java 8) and 2.12.2 (Java 7) fix this issue by removing support for message lookup patterns and disabling JNDI functionality by default."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": [
              {
                "other": "moderate (CVSS: 3.7 AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L)"
              }
            ],
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-917 Improper Neutralization of Special Elements used in an Expression Language Statement (\u0027Expression Language Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html",
                  "refsource": "CONFIRM",
                  "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
                },
                {
                  "name": "https://www.cve.org/CVERecord?id=CVE-2021-44228",
                  "refsource": "MISC",
                  "url": "https://www.cve.org/CVERecord?id=CVE-2021-44228"
                },
                {
                  "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
                },
                {
                  "name": "https://logging.apache.org/log4j/2.x/security.html",
                  "refsource": "CONFIRM",
                  "url": "https://logging.apache.org/log4j/2.x/security.html"
                },
                {
                  "name": "VU#930724",
                  "refsource": "CERT-VN",
                  "url": "https://www.kb.cert.org/vuls/id/930724"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
                },
                {
                  "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html",
                  "refsource": "CONFIRM",
                  "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
                },
                {
                  "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
                  "refsource": "CISCO",
                  "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
                },
                {
                  "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
                },
                {
                  "name": "DSA-5022",
                  "refsource": "DEBIAN",
                  "url": "https://www.debian.org/security/2021/dsa-5022"
                },
                {
                  "name": "[oss-security] 20211218 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                  "refsource": "MLIST",
                  "url": "http://www.openwall.com/lists/oss-security/2021/12/18/1"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
                },
                {
                  "name": "FEDORA-2021-5c9d12a93e",
                  "refsource": "FEDORA",
                  "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/EOKPQGV24RRBBI4TBZUDQMM4MEH7MXCY/"
                },
                {
                  "name": "FEDORA-2021-abbe24e41c",
                  "refsource": "FEDORA",
                  "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SIG7FZULMNK2XF6FZRU4VWYDQXNMUGAJ/"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpujan2022.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpujan2022.html"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpuapr2022.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
                },
                {
                  "name": "https://www.oracle.com/security-alerts/cpujul2022.html",
                  "refsource": "MISC",
                  "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
        "assignerShortName": "apache",
        "cveId": "CVE-2021-45046",
        "datePublished": "2021-12-14T16:55:09.000Z",
        "dateReserved": "2021-12-14T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:25:22.768Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-44228 (GCVE-0-2021-44228)

    Vulnerability from cvelistv5 – Published: 2021-12-10 00:00 – Updated: 2025-10-21 23:25
    Title
    Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints
    Summary
    Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects.
    SSVC
    Exploitation: active Automatable: yes Technical Impact: total
    CISA Coordinator Ā· CISA-ADP (v2.0.3)
    Decision recorded 2025-02-04 14:25 UTC
    CWE
    • CWE-502 - Deserialization of Untrusted Data
    • CWE-400 - Uncontrolled Resource Consumption
    • CWE-20 - Improper Input Validation
    Assigner
    apache CNA under the mitre root
    CNA scorecard B 76/100 over 1271 records in the last 180 days details
    References
    URL Tags
    https://logging.apache.org/log4j/2.x/security.html
    http://www.openwall.com/lists/oss-security/2021/12/10/1 mailing-list
    http://www.openwall.com/lists/oss-security/2021/12/10/2 mailing-list
    https://tools.cisco.com/security/center/content/C… vendor-advisory
    http://www.openwall.com/lists/oss-security/2021/12/10/3 mailing-list
    https://security.netapp.com/advisory/ntap-2021121…
    http://packetstormsecurity.com/files/165225/Apach…
    https://psirt.global.sonicwall.com/vuln-detail/SN…
    https://www.oracle.com/security-alerts/alert-cve-…
    https://www.debian.org/security/2021/dsa-5020 vendor-advisory
    https://lists.debian.org/debian-lts-announce/2021… mailing-list
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    https://msrc-blog.microsoft.com/2021/12/11/micros… vendor-advisory
    http://www.openwall.com/lists/oss-security/2021/12/13/2 mailing-list
    http://www.openwall.com/lists/oss-security/2021/12/13/1 mailing-list
    http://www.openwall.com/lists/oss-security/2021/12/14/4 mailing-list
    https://www.kb.cert.org/vuls/id/930724 third-party-advisory
    https://twitter.com/kurtseifried/status/146934553…
    https://cert-portal.siemens.com/productcert/pdf/s…
    http://packetstormsecurity.com/files/165260/VMwar…
    http://packetstormsecurity.com/files/165270/Apach…
    http://packetstormsecurity.com/files/165261/Apach…
    https://www.intel.com/content/www/us/en/security-…
    http://www.openwall.com/lists/oss-security/2021/12/15/3 mailing-list
    http://packetstormsecurity.com/files/165282/Log4j…
    http://packetstormsecurity.com/files/165281/Log4j…
    http://packetstormsecurity.com/files/165307/Log4j…
    http://packetstormsecurity.com/files/165311/log4j…
    http://packetstormsecurity.com/files/165306/L4sh-…
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://lists.fedoraproject.org/archives/list/pac… vendor-advisory
    http://packetstormsecurity.com/files/165371/VMwar…
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://cert-portal.siemens.com/productcert/pdf/s…
    https://www.oracle.com/security-alerts/cpujan2022.html
    http://packetstormsecurity.com/files/165532/Log4S…
    https://github.com/cisagov/log4j-affected-db/blob…
    http://packetstormsecurity.com/files/165642/VMwar…
    http://packetstormsecurity.com/files/165673/UniFi…
    http://seclists.org/fulldisclosure/2022/Mar/23 mailing-list
    https://www.bentley.com/en/common-vulnerability-e…
    https://github.com/cisagov/log4j-affected-db
    https://support.apple.com/kb/HT213189
    https://www.oracle.com/security-alerts/cpuapr2022.html
    https://github.com/nu11secur1ty/CVE-mitre/tree/ma…
    https://www.nu11secur1ty.com/2021/12/cve-2021-442…
    http://seclists.org/fulldisclosure/2022/Jul/11 mailing-list
    http://packetstormsecurity.com/files/167794/Open-…
    http://packetstormsecurity.com/files/167917/Mobil…
    http://seclists.org/fulldisclosure/2022/Dec/2 mailing-list
    http://packetstormsecurity.com/files/171626/AD-Ma…
    https://www.cisa.gov/known-exploited-vulnerabilit… government-resource
    Impacted products
    Vendor Product Version
    Apache Software Foundation Apache Log4j2 Affected: 2.0-beta9 , < log4j-core* (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:17:24.696Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://logging.apache.org/log4j/2.x/security.html"
              },
              {
                "name": "[oss-security] 20211210 CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/10/1"
              },
              {
                "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/10/2"
              },
              {
                "name": "20211210 Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
              },
              {
                "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/10/3"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20211210-0007/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165225/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
              },
              {
                "name": "DSA-5020",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.debian.org/security/2021/dsa-5020"
              },
              {
                "name": "[debian-lts-announce] 20211212 [SECURITY] [DLA 2842-1] apache-log4j2 security update",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "https://lists.debian.org/debian-lts-announce/2021/12/msg00007.html"
              },
              {
                "name": "FEDORA-2021-f0f501d01f",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VU57UJDCFIASIO35GC55JMKSRXJMCDFM/"
              },
              {
                "name": "Microsoft\u2019s Response to CVE-2021-44228 Apache Log4j 2",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://msrc-blog.microsoft.com/2021/12/11/microsofts-response-to-cve-2021-44228-apache-log4j2/"
              },
              {
                "name": "[oss-security] 20211213 Re: CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/13/2"
              },
              {
                "name": "[oss-security] 20211213 CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/13/1"
              },
              {
                "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
              },
              {
                "name": "20211210 A Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
              },
              {
                "name": "VU#930724",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://www.kb.cert.org/vuls/id/930724"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://twitter.com/kurtseifried/status/1469345530182455296"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165260/VMware-Security-Advisory-2021-0028.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165270/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165261/Apache-Log4j2-2.14.1-Information-Disclosure.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
              },
              {
                "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
              },
              {
                "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165282/Log4j-Payload-Generator.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165281/Log4j2-Log4Shell-Regexes.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165307/Log4j-Remote-Code-Execution-Word-Bypassing.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165311/log4j-scan-Extensive-Scanner.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165306/L4sh-Log4j-Remote-Code-Execution.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
              },
              {
                "name": "FEDORA-2021-66d6c484f3",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/M5CSVUNV4HWZZXGOKNSK6L7RPM7BOKIB/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165371/VMware-Security-Advisory-2021-0028.4.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpujan2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165532/Log4Shell-HTTP-Header-Injection.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/cisagov/log4j-affected-db/blob/develop/SOFTWARE-LIST.md"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165642/VMware-vCenter-Server-Unauthenticated-Log4Shell-JNDI-Injection-Remote-Code-Execution.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/165673/UniFi-Network-Application-Unauthenticated-Log4Shell-Remote-Code-Execution.html"
              },
              {
                "name": "20220314 APPLE-SA-2022-03-14-7 Xcode 13.3",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/Mar/23"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0001"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/cisagov/log4j-affected-db"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.apple.com/kb/HT213189"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/nu11secur1ty/CVE-mitre/tree/main/CVE-2021-44228"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nu11secur1ty.com/2021/12/cve-2021-44228.html"
              },
              {
                "name": "20220721 Open-Xchange Security Advisory 2022-07-21",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/Jul/11"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/167794/Open-Xchange-App-Suite-7.10.x-Cross-Site-Scripting-Command-Injection.html"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/167917/MobileIron-Log4Shell-Remote-Command-Execution.html"
              },
              {
                "name": "20221208 Intel Data Center Manager \u003c= 5.1 Local Privileges Escalation",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2022/Dec/2"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/171626/AD-Manager-Plus-7122-Remote-Code-Execution.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 10,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "CHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-44228",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-04T14:25:34.416117Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2021-12-10",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-44228"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:25:23.121Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-44228"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2021-12-10T00:00:00.000Z",
                "value": "CVE-2021-44228 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Apache Log4j2",
              "vendor": "Apache Software Foundation",
              "versions": [
                {
                  "changes": [
                    {
                      "at": "2.3.1",
                      "status": "unaffected"
                    },
                    {
                      "at": "2.4",
                      "status": "affected"
                    },
                    {
                      "at": "2.12.2",
                      "status": "unaffected"
                    },
                    {
                      "at": "2.13.0",
                      "status": "affected"
                    },
                    {
                      "at": "2.15.0",
                      "status": "unaffected"
                    }
                  ],
                  "lessThan": "log4j-core*",
                  "status": "affected",
                  "version": "2.0-beta9",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "This issue was discovered by Chen Zhaojun of Alibaba Cloud Security Team."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects."
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "other": "critical"
                },
                "type": "unknown"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-502",
                  "description": "CWE-502 Deserialization of Untrusted Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400 Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-04-03T00:00:00.000Z",
            "orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
            "shortName": "apache"
          },
          "references": [
            {
              "url": "https://logging.apache.org/log4j/2.x/security.html"
            },
            {
              "name": "[oss-security] 20211210 CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/10/1"
            },
            {
              "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/10/2"
            },
            {
              "name": "20211210 Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
            },
            {
              "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/10/3"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20211210-0007/"
            },
            {
              "url": "http://packetstormsecurity.com/files/165225/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
            },
            {
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
            },
            {
              "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
            },
            {
              "name": "DSA-5020",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.debian.org/security/2021/dsa-5020"
            },
            {
              "name": "[debian-lts-announce] 20211212 [SECURITY] [DLA 2842-1] apache-log4j2 security update",
              "tags": [
                "mailing-list"
              ],
              "url": "https://lists.debian.org/debian-lts-announce/2021/12/msg00007.html"
            },
            {
              "name": "FEDORA-2021-f0f501d01f",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VU57UJDCFIASIO35GC55JMKSRXJMCDFM/"
            },
            {
              "name": "Microsoft\u2019s Response to CVE-2021-44228 Apache Log4j 2",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://msrc-blog.microsoft.com/2021/12/11/microsofts-response-to-cve-2021-44228-apache-log4j2/"
            },
            {
              "name": "[oss-security] 20211213 Re: CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/13/2"
            },
            {
              "name": "[oss-security] 20211213 CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/13/1"
            },
            {
              "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
            },
            {
              "name": "20211210 A Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
            },
            {
              "name": "VU#930724",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.kb.cert.org/vuls/id/930724"
            },
            {
              "url": "https://twitter.com/kurtseifried/status/1469345530182455296"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
            },
            {
              "url": "http://packetstormsecurity.com/files/165260/VMware-Security-Advisory-2021-0028.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165270/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165261/Apache-Log4j2-2.14.1-Information-Disclosure.html"
            },
            {
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
            },
            {
              "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
            },
            {
              "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
              "tags": [
                "mailing-list"
              ],
              "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
            },
            {
              "url": "http://packetstormsecurity.com/files/165282/Log4j-Payload-Generator.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165281/Log4j2-Log4Shell-Regexes.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165307/Log4j-Remote-Code-Execution-Word-Bypassing.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165311/log4j-scan-Extensive-Scanner.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165306/L4sh-Log4j-Remote-Code-Execution.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
            },
            {
              "name": "FEDORA-2021-66d6c484f3",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/M5CSVUNV4HWZZXGOKNSK6L7RPM7BOKIB/"
            },
            {
              "url": "http://packetstormsecurity.com/files/165371/VMware-Security-Advisory-2021-0028.4.html"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpujan2022.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165532/Log4Shell-HTTP-Header-Injection.html"
            },
            {
              "url": "https://github.com/cisagov/log4j-affected-db/blob/develop/SOFTWARE-LIST.md"
            },
            {
              "url": "http://packetstormsecurity.com/files/165642/VMware-vCenter-Server-Unauthenticated-Log4Shell-JNDI-Injection-Remote-Code-Execution.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/165673/UniFi-Network-Application-Unauthenticated-Log4Shell-Remote-Code-Execution.html"
            },
            {
              "name": "20220314 APPLE-SA-2022-03-14-7 Xcode 13.3",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/Mar/23"
            },
            {
              "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0001"
            },
            {
              "url": "https://github.com/cisagov/log4j-affected-db"
            },
            {
              "url": "https://support.apple.com/kb/HT213189"
            },
            {
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "url": "https://github.com/nu11secur1ty/CVE-mitre/tree/main/CVE-2021-44228"
            },
            {
              "url": "https://www.nu11secur1ty.com/2021/12/cve-2021-44228.html"
            },
            {
              "name": "20220721 Open-Xchange Security Advisory 2022-07-21",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/Jul/11"
            },
            {
              "url": "http://packetstormsecurity.com/files/167794/Open-Xchange-App-Suite-7.10.x-Cross-Site-Scripting-Command-Injection.html"
            },
            {
              "url": "http://packetstormsecurity.com/files/167917/MobileIron-Log4Shell-Remote-Command-Execution.html"
            },
            {
              "name": "20221208 Intel Data Center Manager \u003c= 5.1 Local Privileges Escalation",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2022/Dec/2"
            },
            {
              "url": "http://packetstormsecurity.com/files/171626/AD-Manager-Plus-7122-Remote-Code-Execution.html"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
        "assignerShortName": "apache",
        "cveId": "CVE-2021-44228",
        "datePublished": "2021-12-10T00:00:00.000Z",
        "dateReserved": "2021-11-26T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:25:23.121Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-10933 (GCVE-0-2019-10933)

    Vulnerability from cvelistv5 – Published: 2019-07-11 21:17 – Updated: 2024-08-04 22:40
    VLAI
    Summary
    A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions <= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions < v5.50), Spectrum Power 7 (Corporate User Interface) (All versions <= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user does not need to be logged into the web interface in order for the exploitation to succeed.At the stage of publishing this security advisory no public exploitation is known.
    Severity
    No CVSS data available.
    CWE
    • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:40:15.253Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-747162.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Spectrum Power 3 (Corporate User Interface)",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c= v3.11"
                }
              ]
            },
            {
              "product": "Spectrum Power 4 (Corporate User Interface)",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version v4.75"
                }
              ]
            },
            {
              "product": "Spectrum Power 5 (Corporate User Interface)",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c v5.50"
                }
              ]
            },
            {
              "product": "Spectrum Power 7 (Corporate User Interface)",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c= v2.20"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions \u003c= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions \u003c v5.50), Spectrum Power 7 (Corporate User Interface) (All versions \u003c= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user does not need to be logged into the web interface in order for the exploitation to succeed.At the stage of publishing this security advisory no public exploitation is known."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-80",
                  "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-13T18:55:57.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-747162.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2019-10933",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Spectrum Power 3 (Corporate User Interface)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c= v3.11"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Spectrum Power 4 (Corporate User Interface)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version v4.75"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Spectrum Power 5 (Corporate User Interface)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c v5.50"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Spectrum Power 7 (Corporate User Interface)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c= v2.20"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens AG"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions \u003c= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions \u003c v5.50), Spectrum Power 7 (Corporate User Interface) (All versions \u003c= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user does not need to be logged into the web interface in order for the exploitation to succeed.At the stage of publishing this security advisory no public exploitation is known."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-747162.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-747162.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-10933",
        "datePublished": "2019-07-11T21:17:47.000Z",
        "dateReserved": "2019-04-08T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:40:15.253Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }