    FKIE_CVE-2021-27386

    Vulnerability from fkie_nvd - Published: 2021-05-12 14:15 - Updated: 2026-06-17 03:44
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
    References
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    productcert@siemens.comhttps://us-cert.cisa.gov/ics/advisories/icsa-21-131-12Third Party Advisory, US Government Resource
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12Third Party Advisory, US Government Resource
    Impacted products
    Vendor Product Version
    siemens simatic_wincc_runtime_advanced *
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens sinamics_sh150_firmware *
    siemens sinamics_sh150 -
    siemens sinamics_sm150i_firmware *
    siemens sinamics_sm150i -
    siemens sinamics_gh150_firmware *
    siemens sinamics_gh150 -
    siemens sinamics_gl150_firmware *
    siemens sinamics_gl150 -
    siemens sinamics_gm150_firmware *
    siemens sinamics_gm150 -
    siemens sinamics_sl150_firmware *
    siemens sinamics_sl150 -
    siemens sinamics_sm120_firmware *
    siemens sinamics_sm120 -
    siemens sinamics_sm150_firmware *
    siemens sinamics_sm150 -
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\" -
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\" -
    siemens simatic_hmi_comfort_panels_4\"_firmware *
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\" -
    siemens simatic_hmi_comfort_panels_22\"_firmware *
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\" -
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f -
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700 -
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f -
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900 -
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f -
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\" -
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\" -
    siemens simatic_hmi_comfort_panels_4\"_firmware *
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\" -
    siemens simatic_hmi_comfort_panels_22\"_firmware *
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\" -
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f -
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700 -
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f -
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900 -
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f -
    siemens simatic_wincc_runtime_advanced *
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). SmartVNC presenta una vulnerabilidad de fuga de asignaci\u00f3n de la pila en el manejador de dise\u00f1o del dispositivo en el lado del cliente, lo que podr\u00eda resultar en una condici\u00f3n de Denegaci\u00f3n de Servicio"
        }
      ],
      "id": "CVE-2021-27386",
      "lastModified": "2026-06-17T03:44:45.627",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-27386",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-02T19:06:43.362472Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2021-05-12T14:15:11.767",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-401"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-401"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-27385

    Vulnerability from fkie_nvd - Published: 2021-05-12 14:15 - Updated: 2026-06-17 03:44
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
    Impacted products
    Vendor Product Version
    siemens simatic_wincc_runtime_advanced *
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens sinamics_sh150_firmware *
    siemens sinamics_sh150 -
    siemens sinamics_sm150i_firmware *
    siemens sinamics_sm150i -
    siemens sinamics_gh150_firmware *
    siemens sinamics_gh150 -
    siemens sinamics_gl150_firmware *
    siemens sinamics_gl150 -
    siemens sinamics_gm150_firmware *
    siemens sinamics_gm150 -
    siemens sinamics_sl150_firmware *
    siemens sinamics_sl150 -
    siemens sinamics_sm120_firmware *
    siemens sinamics_sm120 -
    siemens sinamics_sm150_firmware *
    siemens sinamics_sm150 -
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\" -
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\" -
    siemens simatic_hmi_comfort_panels_4\"_firmware *
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\" -
    siemens simatic_hmi_comfort_panels_22\"_firmware *
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\" -
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f -
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700 -
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f -
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900 -
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f -
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\" -
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\" -
    siemens simatic_hmi_comfort_panels_4\"_firmware *
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\" -
    siemens simatic_hmi_comfort_panels_22\"_firmware *
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\" -
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f -
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700 -
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f -
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900 -
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f -
    siemens simatic_wincc_runtime_advanced *
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). Un atacante remoto podr\u00eda enviar paquetes especialmente dise\u00f1ados al manejador de dise\u00f1o de dispositivos SmartVNC en el lado del cliente, lo que podr\u00eda influir en la cantidad de recursos consumidos y dar lugar a una condici\u00f3n de denegaci\u00f3n de servicio (bucle infinito)"
        }
      ],
      "id": "CVE-2021-27385",
      "lastModified": "2026-06-17T03:44:45.383",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-27385",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-02T19:07:48.517703Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2021-05-12T14:15:11.727",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-400"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-835"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-27384

    Vulnerability from fkie_nvd - Published: 2021-05-12 14:15 - Updated: 2026-06-17 03:44
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
    Impacted products
    Vendor Product Version
    siemens simatic_wincc_runtime_advanced *
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens sinamics_sh150_firmware *
    siemens sinamics_sh150 -
    siemens sinamics_sm150i_firmware *
    siemens sinamics_sm150i -
    siemens sinamics_gh150_firmware *
    siemens sinamics_gh150 -
    siemens sinamics_gl150_firmware *
    siemens sinamics_gl150 -
    siemens sinamics_gm150_firmware *
    siemens sinamics_gm150 -
    siemens sinamics_sl150_firmware *
    siemens sinamics_sl150 -
    siemens sinamics_sm120_firmware *
    siemens sinamics_sm120 -
    siemens sinamics_sm150_firmware *
    siemens sinamics_sm150 -
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\" -
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\" -
    siemens simatic_hmi_comfort_panels_4\"_firmware *
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\" -
    siemens simatic_hmi_comfort_panels_22\"_firmware *
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\" -
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f -
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700 -
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f -
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900 -
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f -
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\" -
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\" -
    siemens simatic_hmi_comfort_panels_4\"_firmware *
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\" -
    siemens simatic_hmi_comfort_panels_22\"_firmware *
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\" -
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f -
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700 -
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f -
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900 -
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f -
    siemens simatic_wincc_runtime_advanced *
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones anteriores), SINAMICS GL150 (with option X30) (Todas las versiones anteriores), SINAMICS GM150 (with option X30) (Todas las versiones anteriores), SINAMICS SH150 (Todas las versiones anteriores), SINAMICS SL150 (Todas las versiones anteriores), SINAMICS SM120 (Todas las versiones anteriores), SINAMICS SM150 (Todas las versiones anteriores), SINAMICS SM150i (Todas las versiones anteriores). SmartVNC tiene una vulnerabilidad de acceso a memoria fuera de l\u00edmites en el manejador de dise\u00f1o del dispositivo, representado por un flujo de datos binarios en el lado del cliente, que potencialmente puede resultar en la ejecuci\u00f3n de c\u00f3digo"
        }
      ],
      "id": "CVE-2021-27384",
      "lastModified": "2026-06-17T03:44:45.130",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-27384",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-02T19:09:38.723689Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2021-05-12T14:15:11.677",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-788"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-27383

    Vulnerability from fkie_nvd - Published: 2021-05-12 14:15 - Updated: 2026-06-17 03:44
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
    Impacted products
    Vendor Product Version
    siemens simatic_wincc_runtime_advanced *
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens simatic_wincc_runtime_advanced 16
    siemens sinamics_sh150_firmware *
    siemens sinamics_sh150 -
    siemens sinamics_sm150i_firmware *
    siemens sinamics_sm150i -
    siemens sinamics_gh150_firmware *
    siemens sinamics_gh150 -
    siemens sinamics_gl150_firmware *
    siemens sinamics_gl150 -
    siemens sinamics_gm150_firmware *
    siemens sinamics_gm150 -
    siemens sinamics_sl150_firmware *
    siemens sinamics_sl150 -
    siemens sinamics_sm120_firmware *
    siemens sinamics_sm120 -
    siemens sinamics_sm150_firmware *
    siemens sinamics_sm150 -
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_7\" -
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
    siemens simatic_hmi_comfort_outdoor_panels_15\" -
    siemens simatic_hmi_comfort_panels_4\"_firmware *
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\"_firmware 16
    siemens simatic_hmi_comfort_panels_4\" -
    siemens simatic_hmi_comfort_panels_22\"_firmware *
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\"_firmware 16
    siemens simatic_hmi_comfort_panels_22\" -
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp400f -
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700 -
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp700f -
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900 -
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
    siemens simatic_hmi_ktp_mobile_panels_ktp900f -
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_7\" -
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
    siemens simatic_hmi_comfort_outdoor_panels_15\" -
    siemens simatic_hmi_comfort_panels_4\"_firmware *
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_4\" -
    siemens simatic_hmi_comfort_panels_22\"_firmware *
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
    siemens simatic_hmi_comfort_panels_22\" -
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp400f -
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700 -
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp700f -
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900 -
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
    siemens simatic_hmi_ktp_mobile_panels_ktp900f -
    siemens simatic_wincc_runtime_advanced *
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1
    siemens simatic_wincc_runtime_advanced 15.1

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA",
                  "versionEndExcluding": "16",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA",
                  "versionEndExcluding": "15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con la opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (with option X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). SmartVNC tiene una vulnerabilidad de fuga de asignaci\u00f3n de heap en el codificador Tight del servidor, que podr\u00eda dar lugar a una condici\u00f3n de denegaci\u00f3n de servicio"
        }
      ],
      "id": "CVE-2021-27383",
      "lastModified": "2026-06-17T03:44:44.873",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-27383",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-02T19:20:57.711534Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2021-05-12T14:15:11.633",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-770"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-770"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2020-15798

    Vulnerability from fkie_nvd - Published: 2021-02-09 17:15 - Updated: 2026-06-17 02:57
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 3a"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 3a"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6B7A9D84-336F-4CC3-B86D-1BC212726F3E",
                  "versionEndExcluding": "16.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:-:*:*:*:*:*:*",
                  "matchCriteriaId": "91E96941-4D8D-4473-8F6D-DE4D822DD245",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "AFE4B793-1879-44A3-87B6-A86D7D687FD9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "41238DBB-A315-498B-A8BC-54AB2EC0A9AF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "109E27B6-587F-4E21-9715-4FFBD43DC744",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "50366ACE-B115-448C-A8B2-7903EB070CE7",
                  "versionEndExcluding": "16.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:-:*:*:*:*:*:*",
                  "matchCriteriaId": "BF124F76-F860-4A11-A358-292499D66629",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "B4439C50-FFE9-485E-BD82-7896959E04B2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "7AE2A346-C42B-4B70-8FA8-1B56D9603114",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "96414026-2404-4AFD-B55C-1CD93F729110",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04A1F440-A20A-43BF-8B92-A32F355311DA",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7E108020-A6BA-4C90-BB0A-6E80F3341731",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFC05D55-994D-4F54-AA17-FB4D3A0191A7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9CD365F-139E-42D9-8B1E-31A07E752226",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1AFBC5A7-6DED-4237-8ACC-D0C4C582DE7E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F587131C-64F3-4B89-902C-809B5F095BF3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "28DB0BC6-E60A-4798-80DC-125EF25B3A40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1915386C-8C70-479B-B9AE-2A970CD773C0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)"
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels (incl. Variantes SIPLUS) (Todas las versiones anteriores a  V16 Update 3a), SIMATIC HMI KTP Mobile Panels (Todas las versiones anteriores a  V16 Update 3a), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con la opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (con la opci\u00f3n X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). Los dispositivos afectados con el servicio telnet activado no requieren autenticaci\u00f3n para este servicio. Esto podr\u00eda permitir a un atacante remoto obtener acceso completo al dispositivo. (ZDI-CAN-12046)"
        }
      ],
      "id": "CVE-2020-15798",
      "lastModified": "2026-06-17T02:57:12.663",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 9.3,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2020-15798",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-02T18:59:23.434500Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2021-02-09T17:15:13.437",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-306"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-306"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    }

    CVE-2021-27386 (GCVE-0-2021-27386)

    Vulnerability from nvd – Published: 2021-05-12 13:18 – Updated: 2026-06-02 19:06
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-02 19:06 UTC
    CWE
    • CWE-401 - Missing Release of Memory after Effective Lifetime
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V15 Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V16 Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SINAMICS GH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GL150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GM150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SL150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM120 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150i Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.446Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-27386",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:06:43.362472Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:06:47.812Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-401",
                  "description": "CWE-401: Missing Release of Memory after Effective Lifetime",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-12T09:49:18.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27386",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V15",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V16",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GL150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GM150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SL150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM120",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150i",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-401: Missing Release of Memory after Effective Lifetime"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27386",
        "datePublished": "2021-05-12T13:18:23.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:06:47.812Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-27385 (GCVE-0-2021-27385)

    Vulnerability from nvd – Published: 2021-05-12 13:18 – Updated: 2026-06-02 19:07
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-02 19:07 UTC
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V15 Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V16 Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SINAMICS GH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GL150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GM150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SL150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM120 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150i Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.474Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-27385",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:07:48.517703Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:07:52.624Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-12T09:49:17.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27385",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V15",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V16",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GL150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GM150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SL150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM120",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150i",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-400: Uncontrolled Resource Consumption"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27385",
        "datePublished": "2021-05-12T13:18:23.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:07:52.624Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-27384 (GCVE-0-2021-27384)

    Vulnerability from nvd – Published: 2021-05-12 13:18 – Updated: 2026-06-02 19:09
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-02 19:09 UTC
    CWE
    • CWE-788 - Access of Memory Location After End of Buffer
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V15 Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V16 Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SINAMICS GH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GL150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GM150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SL150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM120 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150i Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.461Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-27384",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:09:38.723689Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:09:41.859Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-788",
                  "description": "CWE-788: Access of Memory Location After End of Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-12T09:49:16.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27384",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V15",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V16",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GL150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GM150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SL150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM120",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150i",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-788: Access of Memory Location After End of Buffer"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27384",
        "datePublished": "2021-05-12T13:18:22.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:09:41.859Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-27383 (GCVE-0-2021-27383)

    Vulnerability from nvd – Published: 2021-05-12 13:18 – Updated: 2026-06-02 19:21
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-02 19:20 UTC
    CWE
    • CWE-770 - Allocation of Resources Without Limits or Throttling
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V15 Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V16 Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SINAMICS GH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GL150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GM150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SL150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM120 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150i Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.589Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-27383",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:20:57.711534Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:21:00.726Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-770",
                  "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-12T09:49:15.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27383",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V15",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V16",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GL150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GM150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SL150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM120",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150i",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-770: Allocation of Resources Without Limits or Throttling"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27383",
        "datePublished": "2021-05-12T13:18:22.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:21:00.726Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2020-15798 (GCVE-0-2020-15798)

    Vulnerability from nvd – Published: 2021-02-09 15:38 – Updated: 2026-06-02 18:59
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-02 18:59 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T13:30:21.706Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-15798",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T18:59:23.434500Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T18:59:33.656Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 3a"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 3a"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-10T10:35:22.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-15798",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 3a"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 3a"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GL150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GM150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SL150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM120",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150i",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306: Missing Authentication for Critical Function"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-15798",
        "datePublished": "2021-02-09T15:38:17.000Z",
        "dateReserved": "2020-07-15T00:00:00.000Z",
        "dateUpdated": "2026-06-02T18:59:33.656Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-27386 (GCVE-0-2021-27386)

    Vulnerability from cvelistv5 – Published: 2021-05-12 13:18 – Updated: 2026-06-02 19:06
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-02 19:06 UTC
    CWE
    • CWE-401 - Missing Release of Memory after Effective Lifetime
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V15 Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V16 Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SINAMICS GH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GL150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GM150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SL150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM120 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150i Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.446Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-27386",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:06:43.362472Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:06:47.812Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-401",
                  "description": "CWE-401: Missing Release of Memory after Effective Lifetime",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-12T09:49:18.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27386",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V15",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V16",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GL150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GM150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SL150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM120",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150i",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-401: Missing Release of Memory after Effective Lifetime"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27386",
        "datePublished": "2021-05-12T13:18:23.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:06:47.812Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-27385 (GCVE-0-2021-27385)

    Vulnerability from cvelistv5 – Published: 2021-05-12 13:18 – Updated: 2026-06-02 19:07
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-02 19:07 UTC
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V15 Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V16 Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SINAMICS GH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GL150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GM150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SL150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM120 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150i Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.474Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-27385",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:07:48.517703Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:07:52.624Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-12T09:49:17.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27385",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V15",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V16",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GL150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GM150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SL150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM120",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150i",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-400: Uncontrolled Resource Consumption"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27385",
        "datePublished": "2021-05-12T13:18:23.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:07:52.624Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-27383 (GCVE-0-2021-27383)

    Vulnerability from cvelistv5 – Published: 2021-05-12 13:18 – Updated: 2026-06-02 19:21
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-02 19:20 UTC
    CWE
    • CWE-770 - Allocation of Resources Without Limits or Throttling
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V15 Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V16 Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SINAMICS GH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GL150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GM150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SL150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM120 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150i Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.589Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-27383",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:20:57.711534Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:21:00.726Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-770",
                  "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-12T09:49:15.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27383",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V15",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V16",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GL150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GM150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SL150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM120",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150i",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-770: Allocation of Resources Without Limits or Throttling"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27383",
        "datePublished": "2021-05-12T13:18:22.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:21:00.726Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-27384 (GCVE-0-2021-27384)

    Vulnerability from cvelistv5 – Published: 2021-05-12 13:18 – Updated: 2026-06-02 19:09
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-02 19:09 UTC
    CWE
    • CWE-788 - Access of Memory Location After End of Buffer
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V15 Affected: All versions < V15.1 Update 6
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced V16 Affected: All versions < V16 Update 4
    Create a notification for this product.
    Siemens SINAMICS GH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GL150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS GM150 (with option X30) Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SH150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SL150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM120 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS SM150i Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.461Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-27384",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:09:38.723689Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:09:41.859Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V15.1 Update 6"
                }
              ]
            },
            {
              "product": "SIMATIC WinCC Runtime Advanced V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 4"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-788",
                  "description": "CWE-788: Access of Memory Location After End of Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-12T09:49:16.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27384",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V15",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V15.1 Update 6"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC WinCC Runtime Advanced V16",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GL150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GM150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SL150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM120",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150i",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-788: Access of Memory Location After End of Buffer"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27384",
        "datePublished": "2021-05-12T13:18:22.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:09:41.859Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2020-15798 (GCVE-0-2020-15798)

    Vulnerability from cvelistv5 – Published: 2021-02-09 15:38 – Updated: 2026-06-02 18:59
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-02 18:59 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T13:30:21.706Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-15798",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T18:59:23.434500Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T18:59:33.656Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 3a"
                }
              ]
            },
            {
              "product": "SIMATIC HMI KTP Mobile Panels",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V16 Update 3a"
                }
              ]
            },
            {
              "product": "SINAMICS GH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GL150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS GM150 (with option X30)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SH150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SL150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM120",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "product": "SINAMICS SM150i",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-10T10:35:22.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-15798",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 3a"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC HMI KTP Mobile Panels",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V16 Update 3a"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GL150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS GM150 (with option X30)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SH150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SL150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM120",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SINAMICS SM150i",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306: Missing Authentication for Critical Function"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-15798",
        "datePublished": "2021-02-09T15:38:17.000Z",
        "dateReserved": "2020-07-15T00:00:00.000Z",
        "dateUpdated": "2026-06-02T18:59:33.656Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }