    6 vulnerabilities found for simatic_mv560_x by siemens

    CVE-2023-36521 (GCVE-0-2023-36521)

    Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-21 14:09
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). The result synchronization server of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of all socket-based communication of the affected products if the result server is enabled.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-21 14:06 UTC
    CWE
    • CWE-770 - Allocation of Resources Without Limits or Throttling
    Impacted products
    Vendor Product Version
    Siemens SIMATIC MV540 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV540 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 U Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 X Affected: All versions < V3.3.4
    Create a notification for this product.
    siemens simatic_mv540_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv540_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_u Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_x Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:52:52.404Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv540_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv540_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv550_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv550_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv560_u",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv560_x",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-36521",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-21T14:06:23.456400Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-21T14:09:57.839Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 U",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 X",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). The result synchronization server of the affected products contains a\r\nvulnerability that may lead to a denial of service condition. An attacker may\r\ncause a denial of service situation of all socket-based communication of the\r\naffected products if the result server is enabled."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-770",
                  "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-11T09:07:13.637Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-36521",
        "datePublished": "2023-07-11T09:07:13.637Z",
        "dateReserved": "2023-06-22T12:37:24.976Z",
        "dateUpdated": "2024-11-21T14:09:57.839Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-35921 (GCVE-0-2023-35921)

    Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-13 14:28
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted Ethernet frames sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-13 14:25 UTC
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Impacted products
    Vendor Product Version
    Siemens SIMATIC MV540 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV540 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 U Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 X Affected: All versions < V3.3.4
    Create a notification for this product.
    siemens simatic_mv540_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv540_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_u Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_x Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:37:40.422Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "simatic_mv540_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "simatic_mv540_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "simatic_mv550_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv550_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "simatic_mv560_u",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "simatic_mv560_x",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-35921",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-13T14:25:45.446014Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-13T14:28:33.242Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 U",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 X",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). Affected devices cannot properly process specially crafted Ethernet frames sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-11T09:07:09.314Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-35921",
        "datePublished": "2023-07-11T09:07:09.314Z",
        "dateReserved": "2023-06-20T10:46:34.162Z",
        "dateUpdated": "2024-11-13T14:28:33.242Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-35920 (GCVE-0-2023-35920)

    Vulnerability from nvd – Published: 2023-07-11 09:07 – Updated: 2024-11-12 16:53
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-12 16:50 UTC
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Impacted products
    Vendor Product Version
    Siemens SIMATIC MV540 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV540 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 U Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 X Affected: All versions < V3.3.4
    Create a notification for this product.
    siemens simatic_mv540_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv540_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_u Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_x Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:37:40.466Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv540_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv540_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv550_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv550_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv560_u",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv560_x",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-35920",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-12T16:50:03.984084Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-12T16:53:53.862Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 U",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 X",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-11T09:07:08.275Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-35920",
        "datePublished": "2023-07-11T09:07:08.275Z",
        "dateReserved": "2023-06-20T10:46:34.162Z",
        "dateUpdated": "2024-11-12T16:53:53.862Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-36521 (GCVE-0-2023-36521)

    Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-21 14:09
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). The result synchronization server of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of all socket-based communication of the affected products if the result server is enabled.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-21 14:06 UTC
    CWE
    • CWE-770 - Allocation of Resources Without Limits or Throttling
    Impacted products
    Vendor Product Version
    Siemens SIMATIC MV540 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV540 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 U Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 X Affected: All versions < V3.3.4
    Create a notification for this product.
    siemens simatic_mv540_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv540_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_u Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_x Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:52:52.404Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv540_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv540_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv550_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv550_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv560_u",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv560_x",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-36521",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-21T14:06:23.456400Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-21T14:09:57.839Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 U",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 X",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). The result synchronization server of the affected products contains a\r\nvulnerability that may lead to a denial of service condition. An attacker may\r\ncause a denial of service situation of all socket-based communication of the\r\naffected products if the result server is enabled."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-770",
                  "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-11T09:07:13.637Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-36521",
        "datePublished": "2023-07-11T09:07:13.637Z",
        "dateReserved": "2023-06-22T12:37:24.976Z",
        "dateUpdated": "2024-11-21T14:09:57.839Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-35921 (GCVE-0-2023-35921)

    Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-13 14:28
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted Ethernet frames sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-13 14:25 UTC
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Impacted products
    Vendor Product Version
    Siemens SIMATIC MV540 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV540 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 U Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 X Affected: All versions < V3.3.4
    Create a notification for this product.
    siemens simatic_mv540_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv540_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_u Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_x Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:37:40.422Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "simatic_mv540_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "simatic_mv540_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "simatic_mv550_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv550_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "simatic_mv560_u",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "simatic_mv560_x",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-35921",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-13T14:25:45.446014Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-13T14:28:33.242Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 U",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 X",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). Affected devices cannot properly process specially crafted Ethernet frames sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-11T09:07:09.314Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-35921",
        "datePublished": "2023-07-11T09:07:09.314Z",
        "dateReserved": "2023-06-20T10:46:34.162Z",
        "dateUpdated": "2024-11-13T14:28:33.242Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-35920 (GCVE-0-2023-35920)

    Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-12 16:53
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-12 16:50 UTC
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Impacted products
    Vendor Product Version
    Siemens SIMATIC MV540 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV540 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 H Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV550 S Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 U Affected: All versions < V3.3.4
    Create a notification for this product.
    Siemens SIMATIC MV560 X Affected: All versions < V3.3.4
    Create a notification for this product.
    siemens simatic_mv540_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv540_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_h Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv550_s Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_u Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*
    Create a notification for this product.
    siemens simatic_mv560_x Affected: 0 , < V3.3.4 (custom)
        cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:37:40.466Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv540_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv540_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv550_h",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv550_s",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv560_u",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_mv560_x",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-35920",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-12T16:50:03.984084Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-12T16:53:53.862Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 U",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 X",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-11T09:07:08.275Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-35920",
        "datePublished": "2023-07-11T09:07:08.275Z",
        "dateReserved": "2023-06-20T10:46:34.162Z",
        "dateUpdated": "2024-11-12T16:53:53.862Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }