Search criteria
8 vulnerabilities found for simatic_cp_1626_firmware by siemens
CVE-2023-37195 (GCVE-0-2023-37195)
Vulnerability from nvd ā Published: 2023-10-10 10:21 ā Updated: 2024-09-19 14:23
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again.
Severity ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1604 |
Affected:
All versions
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:09:34.179Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37195",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-19T14:23:19.334165Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T14:23:36.338Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1623",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1628",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:24.004Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-37195",
"datePublished": "2023-10-10T10:21:24.004Z",
"dateReserved": "2023-06-28T13:43:44.254Z",
"dateUpdated": "2024-09-19T14:23:36.338Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37194 (GCVE-0-2023-37194)
Vulnerability from nvd ā Published: 2023-10-10 10:21 ā Updated: 2024-09-19 14:27
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.
Severity ?
CWE
- CWE-284 - Improper Access Control
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1604 |
Affected:
All versions
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:09:34.104Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1604_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1616_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1623_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1626_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1628_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37194",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-19T14:23:50.733459Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T14:27:20.089Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1623",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1628",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:22.914Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-37194",
"datePublished": "2023-10-10T10:21:22.914Z",
"dateReserved": "2023-06-28T13:43:44.254Z",
"dateUpdated": "2024-09-19T14:27:20.089Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10929 (GCVE-0-2019-10929)
Vulnerability from nvd ā Published: 2019-08-13 18:55 ā Updated: 2024-08-04 22:40
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.
Severity ?
No CVSS data available.
CWE
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.230Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V20.8"
}
]
},
{
"product": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0"
}
]
},
{
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.8.1"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V20.8"
}
]
},
{
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC OA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.16 P013"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:07",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC CP 1626",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1 Update 14"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V15",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.4.0"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.8.1"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC S7-PLCSIM Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC OA",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.16 P013"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10929",
"datePublished": "2019-08-13T18:55:57",
"dateReserved": "2019-04-08T00:00:00",
"dateUpdated": "2024-08-04T22:40:15.230Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-2680 (GCVE-0-2017-2680)
Vulnerability from nvd ā Published: 2017-05-11 01:00 ā Updated: 2024-09-10 09:33
VLAI?
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Severity ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
| URL | Tags | |||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Affected:
All versions < V4.1.1 Patch04
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-2680",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T13:26:04.237652Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T13:26:15.327Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:02:07.270Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.1 Patch04"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1 Patch03"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0 Patch01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 12\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 15\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 19\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 22\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/AS-i Link PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/PB-Link (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.03"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W-700 IEEE 802.11n family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X408 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X414",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.10.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM-400 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR-500 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 OPC UA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC DK-16xx PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200M (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-3 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-4 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN: IO-Link Master",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200S (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 HR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 SR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 UR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF650R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF680R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF685R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.X.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Basic",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Standard",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4 HF26"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCM w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.4 SP1 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCP w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G110M w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V4.7: All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GH150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP5 HF7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GL150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GM150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF31"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S110 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4 SP3 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.0 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF30"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.4 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.5 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM120 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS V90 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS ACT 3SU1 interface module PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Motor Starter M200D PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter 3RW44 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP PSU8600 PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "Softnet PROFINET IO for PC-based Windows systems",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:18.492Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2017-2680",
"datePublished": "2017-05-11T01:00:00",
"dateReserved": "2016-12-01T00:00:00",
"dateUpdated": "2024-09-10T09:33:18.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37195 (GCVE-0-2023-37195)
Vulnerability from cvelistv5 ā Published: 2023-10-10 10:21 ā Updated: 2024-09-19 14:23
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again.
Severity ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1604 |
Affected:
All versions
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:09:34.179Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37195",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-19T14:23:19.334165Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T14:23:36.338Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1623",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1628",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:24.004Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-37195",
"datePublished": "2023-10-10T10:21:24.004Z",
"dateReserved": "2023-06-28T13:43:44.254Z",
"dateUpdated": "2024-09-19T14:23:36.338Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37194 (GCVE-0-2023-37194)
Vulnerability from cvelistv5 ā Published: 2023-10-10 10:21 ā Updated: 2024-09-19 14:27
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.
Severity ?
CWE
- CWE-284 - Improper Access Control
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1604 |
Affected:
All versions
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:09:34.104Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1604_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1616_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1623_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1626_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1628_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37194",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-19T14:23:50.733459Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T14:27:20.089Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1623",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1628",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:22.914Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-37194",
"datePublished": "2023-10-10T10:21:22.914Z",
"dateReserved": "2023-06-28T13:43:44.254Z",
"dateUpdated": "2024-09-19T14:27:20.089Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10929 (GCVE-0-2019-10929)
Vulnerability from cvelistv5 ā Published: 2019-08-13 18:55 ā Updated: 2024-08-04 22:40
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.
Severity ?
No CVSS data available.
CWE
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1626 |
Affected:
All versions
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.230Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V20.8"
}
]
},
{
"product": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0"
}
]
},
{
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.8.1"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V20.8"
}
]
},
{
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC OA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.16 P013"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:07",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC CP 1626",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1 Update 14"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V15",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.4.0"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.8.1"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC S7-PLCSIM Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC OA",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.16 P013"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10929",
"datePublished": "2019-08-13T18:55:57",
"dateReserved": "2019-04-08T00:00:00",
"dateUpdated": "2024-08-04T22:40:15.230Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-2680 (GCVE-0-2017-2680)
Vulnerability from cvelistv5 ā Published: 2017-05-11 01:00 ā Updated: 2024-09-10 09:33
VLAI?
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Severity ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
| URL | Tags | |||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Affected:
All versions < V4.1.1 Patch04
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-2680",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T13:26:04.237652Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T13:26:15.327Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:02:07.270Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.1 Patch04"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1 Patch03"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0 Patch01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 12\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 15\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 19\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 22\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/AS-i Link PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/PB-Link (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.03"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W-700 IEEE 802.11n family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X408 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X414",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.10.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM-400 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR-500 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 OPC UA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC DK-16xx PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200M (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-3 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-4 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN: IO-Link Master",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200S (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 HR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 SR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 UR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF650R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF680R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF685R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.X.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Basic",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Standard",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4 HF26"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCM w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.4 SP1 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCP w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G110M w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V4.7: All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GH150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP5 HF7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GL150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GM150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF31"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S110 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4 SP3 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.0 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF30"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.4 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.5 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM120 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS V90 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS ACT 3SU1 interface module PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Motor Starter M200D PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter 3RW44 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP PSU8600 PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "Softnet PROFINET IO for PC-based Windows systems",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:18.492Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2017-2680",
"datePublished": "2017-05-11T01:00:00",
"dateReserved": "2016-12-01T00:00:00",
"dateUpdated": "2024-09-10T09:33:18.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}