Search criteria
10 vulnerabilities found for simatic_cp_1542sp-1_firmware by siemens
CVE-2022-43768 (GCVE-0-2022-43768)
Vulnerability from nvd – Published: 2023-04-11 09:02 – Updated: 2025-02-07 16:51
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Severity ?
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43768",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T16:50:58.868618Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T16:51:07.850Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:34.861Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43768",
"datePublished": "2023-04-11T09:02:51.623Z",
"dateReserved": "2022-10-26T11:27:16.347Z",
"dateUpdated": "2025-02-07T16:51:07.850Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43767 (GCVE-0-2022-43767)
Vulnerability from nvd – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Severity ?
CWE
- CWE-833 - Deadlock
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1543sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_dnp3",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_iec",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_eu",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_us",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-8_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43767",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-12T19:11:06.737320Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-12T20:11:32.129Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.317Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-833",
"description": "CWE-833: Deadlock",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:33.351Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43767",
"datePublished": "2023-04-11T09:02:50.497Z",
"dateReserved": "2022-10-26T11:27:16.347Z",
"dateUpdated": "2024-09-10T09:33:33.351Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43716 (GCVE-0-2022-43716)
Vulnerability from nvd – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.
Severity ?
CWE
- CWE-416 - Use After Free
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1242-7_gprs_v2",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_dnp3",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_iec",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_eu",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_us",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-8:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-8",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1543sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1_rail",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43716",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T14:12:55.560896Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T14:35:43.227Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.265Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416: Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:31.854Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43716",
"datePublished": "2023-04-11T09:02:49.383Z",
"dateReserved": "2022-10-24T05:19:12.272Z",
"dateUpdated": "2024-09-10T09:33:31.854Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-41991 (GCVE-0-2021-41991)
Vulnerability from nvd – Published: 2021-10-18 13:44 – Updated: 2024-08-04 03:22
VLAI?
Summary
The in-memory certificate cache in strongSwan before 5.9.4 has a remote integer overflow upon receiving many requests with different certificates to fill the cache and later trigger the replacement of cache entries. The code attempts to select a less-often-used cache entry by means of a random number generator, but this is not done correctly. Remote code execution might be a slight possibility.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T03:22:25.655Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/strongswan/strongswan/releases/tag/5.9.4"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.strongswan.org/blog/2021/10/18/strongswan-vulnerability-%28cve-2021-41991%29.html"
},
{
"name": "DSA-4989",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN",
"x_transferred"
],
"url": "https://www.debian.org/security/2021/dsa-4989"
},
{
"name": "[debian-lts-announce] 20211019 [SECURITY] [DLA 2788-1] strongswan security update",
"tags": [
"mailing-list",
"x_refsource_MLIST",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/10/msg00014.html"
},
{
"name": "FEDORA-2021-0b37146973",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/5FJSATD2R2XHTG4P63GCMQ2N7EWKMME5/"
},
{
"name": "FEDORA-2021-b3df83339e",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WQSQ3BEC22NF4NCDZVCT4P3Q2ZIAJXGJ/"
},
{
"name": "FEDORA-2021-95fab6a482",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/Y3TQ32JLJOBJDB2EJKSX2PBPB5NFG2D4/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-539476.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The in-memory certificate cache in strongSwan before 5.9.4 has a remote integer overflow upon receiving many requests with different certificates to fill the cache and later trigger the replacement of cache entries. The code attempts to select a less-often-used cache entry by means of a random number generator, but this is not done correctly. Remote code execution might be a slight possibility."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-08T12:06:09",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/strongswan/strongswan/releases/tag/5.9.4"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.strongswan.org/blog/2021/10/18/strongswan-vulnerability-%28cve-2021-41991%29.html"
},
{
"name": "DSA-4989",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN"
],
"url": "https://www.debian.org/security/2021/dsa-4989"
},
{
"name": "[debian-lts-announce] 20211019 [SECURITY] [DLA 2788-1] strongswan security update",
"tags": [
"mailing-list",
"x_refsource_MLIST"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/10/msg00014.html"
},
{
"name": "FEDORA-2021-0b37146973",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/5FJSATD2R2XHTG4P63GCMQ2N7EWKMME5/"
},
{
"name": "FEDORA-2021-b3df83339e",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WQSQ3BEC22NF4NCDZVCT4P3Q2ZIAJXGJ/"
},
{
"name": "FEDORA-2021-95fab6a482",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/Y3TQ32JLJOBJDB2EJKSX2PBPB5NFG2D4/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-539476.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41991",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The in-memory certificate cache in strongSwan before 5.9.4 has a remote integer overflow upon receiving many requests with different certificates to fill the cache and later trigger the replacement of cache entries. The code attempts to select a less-often-used cache entry by means of a random number generator, but this is not done correctly. Remote code execution might be a slight possibility."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/strongswan/strongswan/releases/tag/5.9.4",
"refsource": "MISC",
"url": "https://github.com/strongswan/strongswan/releases/tag/5.9.4"
},
{
"name": "https://www.strongswan.org/blog/2021/10/18/strongswan-vulnerability-(cve-2021-41991).html",
"refsource": "CONFIRM",
"url": "https://www.strongswan.org/blog/2021/10/18/strongswan-vulnerability-(cve-2021-41991).html"
},
{
"name": "DSA-4989",
"refsource": "DEBIAN",
"url": "https://www.debian.org/security/2021/dsa-4989"
},
{
"name": "[debian-lts-announce] 20211019 [SECURITY] [DLA 2788-1] strongswan security update",
"refsource": "MLIST",
"url": "https://lists.debian.org/debian-lts-announce/2021/10/msg00014.html"
},
{
"name": "FEDORA-2021-0b37146973",
"refsource": "FEDORA",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/5FJSATD2R2XHTG4P63GCMQ2N7EWKMME5/"
},
{
"name": "FEDORA-2021-b3df83339e",
"refsource": "FEDORA",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/WQSQ3BEC22NF4NCDZVCT4P3Q2ZIAJXGJ/"
},
{
"name": "FEDORA-2021-95fab6a482",
"refsource": "FEDORA",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/Y3TQ32JLJOBJDB2EJKSX2PBPB5NFG2D4/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-539476.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-539476.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41991",
"datePublished": "2021-10-18T13:44:25",
"dateReserved": "2021-10-04T00:00:00",
"dateUpdated": "2024-08-04T03:22:25.655Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-2680 (GCVE-0-2017-2680)
Vulnerability from nvd – Published: 2017-05-11 01:00 – Updated: 2024-09-10 09:33
VLAI?
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Severity ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
| URL | Tags | |||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-2680",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T13:26:04.237652Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T13:26:15.327Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:02:07.270Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.1 Patch04"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1 Patch03"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0 Patch01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 12\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 15\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 19\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 22\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/AS-i Link PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/PB-Link (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.03"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W-700 IEEE 802.11n family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X408 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X414",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.10.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM-400 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR-500 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 OPC UA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC DK-16xx PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200M (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-3 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-4 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN: IO-Link Master",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200S (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 HR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 SR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 UR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF650R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF680R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF685R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.X.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Basic",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Standard",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4 HF26"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCM w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.4 SP1 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCP w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G110M w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V4.7: All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GH150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP5 HF7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GL150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GM150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF31"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S110 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4 SP3 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.0 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF30"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.4 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.5 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM120 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS V90 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS ACT 3SU1 interface module PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Motor Starter M200D PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter 3RW44 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP PSU8600 PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "Softnet PROFINET IO for PC-based Windows systems",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:18.492Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2017-2680",
"datePublished": "2017-05-11T01:00:00",
"dateReserved": "2016-12-01T00:00:00",
"dateUpdated": "2024-09-10T09:33:18.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43768 (GCVE-0-2022-43768)
Vulnerability from cvelistv5 – Published: 2023-04-11 09:02 – Updated: 2025-02-07 16:51
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Severity ?
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43768",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T16:50:58.868618Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T16:51:07.850Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:34.861Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43768",
"datePublished": "2023-04-11T09:02:51.623Z",
"dateReserved": "2022-10-26T11:27:16.347Z",
"dateUpdated": "2025-02-07T16:51:07.850Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43767 (GCVE-0-2022-43767)
Vulnerability from cvelistv5 – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
Severity ?
CWE
- CWE-833 - Deadlock
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1543sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_dnp3",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_iec",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_eu",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_us",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-8_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43767",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-12T19:11:06.737320Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-12T20:11:32.129Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.317Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-833",
"description": "CWE-833: Deadlock",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:33.351Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43767",
"datePublished": "2023-04-11T09:02:50.497Z",
"dateReserved": "2022-10-26T11:27:16.347Z",
"dateUpdated": "2024-09-10T09:33:33.351Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43716 (GCVE-0-2022-43716)
Vulnerability from cvelistv5 – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.
Severity ?
CWE
- CWE-416 - Use After Free
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 |
Affected:
0 , < V3.4.29
(custom)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1242-7_gprs_v2",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_dnp3",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-1_iec",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_eu",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-7_lte_us",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1243-8:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1243-8",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1542sp-1_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cp_1543sp-1",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_443-1_advanced",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_net_cp_1242-7_v2",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-1200_cp_1243-1_rail",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_tim_1531_irc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43716",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T14:12:55.560896Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T14:35:43.227Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.265Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.4.29",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIM 1531 IRC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416: Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:31.854Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43716",
"datePublished": "2023-04-11T09:02:49.383Z",
"dateReserved": "2022-10-24T05:19:12.272Z",
"dateUpdated": "2024-09-10T09:33:31.854Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-41991 (GCVE-0-2021-41991)
Vulnerability from cvelistv5 – Published: 2021-10-18 13:44 – Updated: 2024-08-04 03:22
VLAI?
Summary
The in-memory certificate cache in strongSwan before 5.9.4 has a remote integer overflow upon receiving many requests with different certificates to fill the cache and later trigger the replacement of cache entries. The code attempts to select a less-often-used cache entry by means of a random number generator, but this is not done correctly. Remote code execution might be a slight possibility.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T03:22:25.655Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/strongswan/strongswan/releases/tag/5.9.4"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.strongswan.org/blog/2021/10/18/strongswan-vulnerability-%28cve-2021-41991%29.html"
},
{
"name": "DSA-4989",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN",
"x_transferred"
],
"url": "https://www.debian.org/security/2021/dsa-4989"
},
{
"name": "[debian-lts-announce] 20211019 [SECURITY] [DLA 2788-1] strongswan security update",
"tags": [
"mailing-list",
"x_refsource_MLIST",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/10/msg00014.html"
},
{
"name": "FEDORA-2021-0b37146973",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/5FJSATD2R2XHTG4P63GCMQ2N7EWKMME5/"
},
{
"name": "FEDORA-2021-b3df83339e",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WQSQ3BEC22NF4NCDZVCT4P3Q2ZIAJXGJ/"
},
{
"name": "FEDORA-2021-95fab6a482",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/Y3TQ32JLJOBJDB2EJKSX2PBPB5NFG2D4/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-539476.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The in-memory certificate cache in strongSwan before 5.9.4 has a remote integer overflow upon receiving many requests with different certificates to fill the cache and later trigger the replacement of cache entries. The code attempts to select a less-often-used cache entry by means of a random number generator, but this is not done correctly. Remote code execution might be a slight possibility."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-08T12:06:09",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/strongswan/strongswan/releases/tag/5.9.4"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.strongswan.org/blog/2021/10/18/strongswan-vulnerability-%28cve-2021-41991%29.html"
},
{
"name": "DSA-4989",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN"
],
"url": "https://www.debian.org/security/2021/dsa-4989"
},
{
"name": "[debian-lts-announce] 20211019 [SECURITY] [DLA 2788-1] strongswan security update",
"tags": [
"mailing-list",
"x_refsource_MLIST"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/10/msg00014.html"
},
{
"name": "FEDORA-2021-0b37146973",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/5FJSATD2R2XHTG4P63GCMQ2N7EWKMME5/"
},
{
"name": "FEDORA-2021-b3df83339e",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WQSQ3BEC22NF4NCDZVCT4P3Q2ZIAJXGJ/"
},
{
"name": "FEDORA-2021-95fab6a482",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/Y3TQ32JLJOBJDB2EJKSX2PBPB5NFG2D4/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-539476.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41991",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The in-memory certificate cache in strongSwan before 5.9.4 has a remote integer overflow upon receiving many requests with different certificates to fill the cache and later trigger the replacement of cache entries. The code attempts to select a less-often-used cache entry by means of a random number generator, but this is not done correctly. Remote code execution might be a slight possibility."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/strongswan/strongswan/releases/tag/5.9.4",
"refsource": "MISC",
"url": "https://github.com/strongswan/strongswan/releases/tag/5.9.4"
},
{
"name": "https://www.strongswan.org/blog/2021/10/18/strongswan-vulnerability-(cve-2021-41991).html",
"refsource": "CONFIRM",
"url": "https://www.strongswan.org/blog/2021/10/18/strongswan-vulnerability-(cve-2021-41991).html"
},
{
"name": "DSA-4989",
"refsource": "DEBIAN",
"url": "https://www.debian.org/security/2021/dsa-4989"
},
{
"name": "[debian-lts-announce] 20211019 [SECURITY] [DLA 2788-1] strongswan security update",
"refsource": "MLIST",
"url": "https://lists.debian.org/debian-lts-announce/2021/10/msg00014.html"
},
{
"name": "FEDORA-2021-0b37146973",
"refsource": "FEDORA",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/5FJSATD2R2XHTG4P63GCMQ2N7EWKMME5/"
},
{
"name": "FEDORA-2021-b3df83339e",
"refsource": "FEDORA",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/WQSQ3BEC22NF4NCDZVCT4P3Q2ZIAJXGJ/"
},
{
"name": "FEDORA-2021-95fab6a482",
"refsource": "FEDORA",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/Y3TQ32JLJOBJDB2EJKSX2PBPB5NFG2D4/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-539476.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-539476.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41991",
"datePublished": "2021-10-18T13:44:25",
"dateReserved": "2021-10-04T00:00:00",
"dateUpdated": "2024-08-04T03:22:25.655Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-2680 (GCVE-0-2017-2680)
Vulnerability from cvelistv5 – Published: 2017-05-11 01:00 – Updated: 2024-09-10 09:33
VLAI?
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Severity ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
| URL | Tags | |||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Affected:
All versions < V4.1.1 Patch04
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-2680",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T13:26:04.237652Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T13:26:15.327Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:02:07.270Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.1 Patch04"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1 Patch03"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0 Patch01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 12\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 15\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 19\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 22\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/AS-i Link PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/PB-Link (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.03"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W-700 IEEE 802.11n family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X408 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X414",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.10.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM-400 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR-500 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 OPC UA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC DK-16xx PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200M (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-3 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-4 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN: IO-Link Master",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200S (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 HR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 SR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 UR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF650R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF680R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF685R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.X.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Basic",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Standard",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4 HF26"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCM w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.4 SP1 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCP w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G110M w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V4.7: All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GH150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP5 HF7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GL150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GM150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF31"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S110 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4 SP3 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.0 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF30"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.4 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.5 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM120 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS V90 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS ACT 3SU1 interface module PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Motor Starter M200D PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter 3RW44 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP PSU8600 PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "Softnet PROFINET IO for PC-based Windows systems",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:18.492Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2017-2680",
"datePublished": "2017-05-11T01:00:00",
"dateReserved": "2016-12-01T00:00:00",
"dateUpdated": "2024-09-10T09:33:18.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}