CVE-2022-43768 (GCVE-0-2022-43768)

Vulnerability from nvd – Published: 2023-04-11 09:02 – Updated: 2025-02-07 16:51
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
CWE
  • CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
    Siemens TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.422Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43768",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-07T16:50:58.868618Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-07T16:51:07.850Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:34.861Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-43768",
    "datePublished": "2023-04-11T09:02:51.623Z",
    "dateReserved": "2022-10-26T11:27:16.347Z",
    "dateUpdated": "2025-02-07T16:51:07.850Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43767 (GCVE-0-2022-43767)

Vulnerability from nvd – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
    Siemens TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1543sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_1242-7_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1242-7_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_dnp3",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_iec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_eu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_us",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-8_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43767",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-12T19:11:06.737320Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-12T20:11:32.129Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.317Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-833",
              "description": "CWE-833: Deadlock",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:33.351Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-43767",
    "datePublished": "2023-04-11T09:02:50.497Z",
    "dateReserved": "2022-10-26T11:27:16.347Z",
    "dateUpdated": "2024-09-10T09:33:33.351Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43716 (GCVE-0-2022-43716)

Vulnerability from nvd – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
    Siemens TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1242-7_gprs_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_dnp3",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_iec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_eu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_us",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-8:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-8",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1543sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_1242-7_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43716",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T14:12:55.560896Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T14:35:43.227Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.265Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416: Use After Free",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:31.854Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-43716",
    "datePublished": "2023-04-11T09:02:49.383Z",
    "dateReserved": "2022-10-24T05:19:12.272Z",
    "dateUpdated": "2024-09-10T09:33:31.854Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34821 (GCVE-0-2022-34821)

Vulnerability from nvd – Published: 2022-07-12 00:00 – Updated: 2025-04-21 13:52
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges.
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) EU Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RM1224 LTE(4G) NAM Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M804PB Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M812-1 ADSL-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M812-1 ADSL-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M816-1 ADSL-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M816-1 ADSL-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M826-2 SHDSL-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M874-2 Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M874-3 Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M876-3 Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M876-3 (ROK) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M876-4 Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M876-4 (EU) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M876-4 (NAM) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE MUM853-1 (EU) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE MUM856-1 (EU) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE MUM856-1 (RoW) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE S615 EEC LAN-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE S615 LAN-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE SC622-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC622-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC626-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC626-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC632-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC632-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC636-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC636-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC642-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC642-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC646-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC646-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAB762-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM763-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM763-1 (ME) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM763-1 (US) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 (ME) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 (US) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 EEC Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 EEC (ME) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 EEC (US) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUB762-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUB762-1 iFeatures Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 (US) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 (US) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM766-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM766-1 (ME) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM766-1 (USA) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: V2.0 , < V2.2.28 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: V2.0 , < V2.2.28 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: V2.0 , < V2.2.28 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: V2.0 , < V2.2.28 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: V2.0 , < V2.2.28 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS NET CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: All versions < V3.3.46
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:22:10.733Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34821",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:23:16.425380Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:52:26.030Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1 iFeatures",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.6,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T10:26:58.220Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-517377.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34821",
    "datePublished": "2022-07-12T00:00:00.000Z",
    "dateReserved": "2022-06-29T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:52:26.030Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34820 (GCVE-0-2022-34820)

Vulnerability from nvd – Published: 2022-07-12 10:07 – Updated: 2025-04-21 13:51
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIMATIC CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS NET CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: All versions < V3.3.46
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:22:10.675Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34820",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:22:59.563603Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:51:29.230Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions \u003c V3.3.46), SIMATIC CP 1243-1 (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE US (All versions \u003c V3.3.46), SIMATIC CP 1243-8 IRC (All versions \u003c V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions \u003e= V2.0 \u003c V2.2.28), SIMATIC CP 1543-1 (All versions \u003c V3.0.22), SIMATIC CP 1543SP-1 (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions \u003c V3.3.46), SIPLUS NET CP 1543-1 (All versions \u003c V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions \u003c V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions \u003c V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-14T09:30:39.103Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34820",
    "datePublished": "2022-07-12T10:07:29.000Z",
    "dateReserved": "2022-06-29T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:51:29.230Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34819 (GCVE-0-2022-34819)

Vulnerability from nvd – Published: 2022-07-12 10:07 – Updated: 2025-04-21 13:51
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIMATIC CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS NET CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: All versions < V3.3.46
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:22:10.546Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34819",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:11:00.365420Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:51:38.353Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions \u003c V3.3.46), SIMATIC CP 1243-1 (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE US (All versions \u003c V3.3.46), SIMATIC CP 1243-8 IRC (All versions \u003c V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions \u003e= V2.0 \u003c V2.2.28), SIMATIC CP 1543-1 (All versions \u003c V3.0.22), SIMATIC CP 1543SP-1 (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions \u003c V3.3.46), SIPLUS NET CP 1543-1 (All versions \u003c V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions \u003c V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions \u003c V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-14T09:30:37.921Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34819",
    "datePublished": "2022-07-12T10:07:27.000Z",
    "dateReserved": "2022-06-29T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:51:38.353Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43768 (GCVE-0-2022-43768)

Vulnerability from cvelistv5 – Published: 2023-04-11 09:02 – Updated: 2025-02-07 16:51
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
CWE
  • CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
    Siemens TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.422Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43768",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-07T16:50:58.868618Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-07T16:51:07.850Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:34.861Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-43768",
    "datePublished": "2023-04-11T09:02:51.623Z",
    "dateReserved": "2022-10-26T11:27:16.347Z",
    "dateUpdated": "2025-02-07T16:51:07.850Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43767 (GCVE-0-2022-43767)

Vulnerability from cvelistv5 – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
    Siemens TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1543sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_1242-7_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1242-7_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_dnp3",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_iec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_eu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_us",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-8_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43767",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-12T19:11:06.737320Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-12T20:11:32.129Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.317Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-833",
              "description": "CWE-833: Deadlock",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:33.351Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-43767",
    "datePublished": "2023-04-11T09:02:50.497Z",
    "dateReserved": "2022-10-26T11:27:16.347Z",
    "dateUpdated": "2024-09-10T09:33:33.351Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-43716 (GCVE-0-2022-43716)

Vulnerability from cvelistv5 – Published: 2023-04-11 09:02 – Updated: 2024-09-10 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Advanced Affected: 0 , < V3.3 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: 0 , < V3.4.29 (custom)
Create a notification for this product.
    Siemens SIPLUS TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
    Siemens TIM 1531 IRC Affected: 0 , < V2.3.6 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1242-7_gprs_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_dnp3",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-1_iec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_eu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-7_lte_us",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1243-8:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1243-8",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1542sp-1_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cp_1543sp-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cp_1543sp-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1542sp-1_irc_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_et_200sp_cp_1543sp-1_isec_tx_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_443-1_advanced:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_443-1_advanced",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_net_cp_1242-7_v2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-1200_cp_1243-1_rail",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_tim_1531_irc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_tim_1531_irc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.3.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43716",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T14:12:55.560896Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T14:35:43.227Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:40:06.265Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.4.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions \u003c V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions \u003c V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions \u003c V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions \u003c V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions \u003c V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions \u003c V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions \u003c V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions \u003c V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions \u003c V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416: Use After Free",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:31.854Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-139628.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-566905.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-43716",
    "datePublished": "2023-04-11T09:02:49.383Z",
    "dateReserved": "2022-10-24T05:19:12.272Z",
    "dateUpdated": "2024-09-10T09:33:31.854Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34820 (GCVE-0-2022-34820)

Vulnerability from cvelistv5 – Published: 2022-07-12 10:07 – Updated: 2025-04-21 13:51
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIMATIC CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS NET CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: All versions < V3.3.46
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:22:10.675Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34820",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:22:59.563603Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:51:29.230Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions \u003c V3.3.46), SIMATIC CP 1243-1 (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE US (All versions \u003c V3.3.46), SIMATIC CP 1243-8 IRC (All versions \u003c V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions \u003e= V2.0 \u003c V2.2.28), SIMATIC CP 1543-1 (All versions \u003c V3.0.22), SIMATIC CP 1543SP-1 (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions \u003c V3.3.46), SIPLUS NET CP 1543-1 (All versions \u003c V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions \u003c V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions \u003c V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-14T09:30:39.103Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34820",
    "datePublished": "2022-07-12T10:07:29.000Z",
    "dateReserved": "2022-06-29T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:51:29.230Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34819 (GCVE-0-2022-34819)

Vulnerability from cvelistv5 – Published: 2022-07-12 10:07 – Updated: 2025-04-21 13:51
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIMATIC CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: All versions >= V2.0 < V2.2.28
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS NET CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: All versions < V3.3.46
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:22:10.546Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34819",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:11:00.365420Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:51:38.353Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.2.28"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions \u003c V3.3.46), SIMATIC CP 1243-1 (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE US (All versions \u003c V3.3.46), SIMATIC CP 1243-8 IRC (All versions \u003c V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions \u003e= V2.0 \u003c V2.2.28), SIMATIC CP 1543-1 (All versions \u003c V3.0.22), SIMATIC CP 1543SP-1 (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions \u003c V3.3.46), SIPLUS NET CP 1543-1 (All versions \u003c V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions \u003c V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions \u003c V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-14T09:30:37.921Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34819",
    "datePublished": "2022-07-12T10:07:27.000Z",
    "dateReserved": "2022-06-29T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:51:38.353Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34821 (GCVE-0-2022-34821)

Vulnerability from cvelistv5 – Published: 2022-07-12 00:00 – Updated: 2025-04-21 13:52
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges.
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) EU Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RM1224 LTE(4G) NAM Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M804PB Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M812-1 ADSL-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M812-1 ADSL-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M816-1 ADSL-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M816-1 ADSL-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M826-2 SHDSL-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M874-2 Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M874-3 Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M876-3 Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M876-3 (ROK) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M876-4 Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M876-4 (EU) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE M876-4 (NAM) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE MUM853-1 (EU) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE MUM856-1 (EU) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE MUM856-1 (RoW) Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE S615 EEC LAN-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE S615 LAN-Router Affected: 0 , < V7.2 (custom)
Create a notification for this product.
    Siemens SCALANCE SC622-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC622-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC626-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC626-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC632-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC632-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC636-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC636-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC642-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC642-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC646-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC646-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAB762-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM763-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM763-1 (ME) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM763-1 (US) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 (ME) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 (US) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 EEC Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 EEC (ME) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 EEC (US) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUB762-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUB762-1 iFeatures Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 (US) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 (US) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM766-1 Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM766-1 (ME) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM766-1 (USA) Affected: 0 , < V3.0.0 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE EU Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-7 LTE US Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1243-8 IRC Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIMATIC CP 1542SP-1 IRC Affected: V2.0 , < V2.2.28 (custom)
Create a notification for this product.
    Siemens SIMATIC CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIMATIC CP 1543SP-1 Affected: V2.0 , < V2.2.28 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL Affected: V2.0 , < V2.2.28 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC Affected: V2.0 , < V2.2.28 (custom)
Create a notification for this product.
    Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL Affected: V2.0 , < V2.2.28 (custom)
Create a notification for this product.
    Siemens SIPLUS NET CP 1242-7 V2 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS NET CP 1543-1 Affected: All versions < V3.0.22
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 Affected: All versions < V3.3.46
Create a notification for this product.
    Siemens SIPLUS S7-1200 CP 1243-1 RAIL Affected: All versions < V3.3.46
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:22:10.733Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34821",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:23:16.425380Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:52:26.030Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1 iFeatures",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE EU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2.28",
              "status": "affected",
              "version": "V2.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1242-7 V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 1543-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.46"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), SCALANCE M874-2 (6GK5874-2AA00-2AA2), SCALANCE M874-3 (6GK5874-3AA00-2AA2), SCALANCE M876-3 (6GK5876-3AA02-2BA2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2), SCALANCE M876-4 (6GK5876-4AA10-2BA2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC636-2C (6GK5636-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC642-2C (6GK5642-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE SC646-2C (6GK5646-2GS00-2AC2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0), SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.6,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T10:26:58.220Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-517377.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34821",
    "datePublished": "2022-07-12T00:00:00.000Z",
    "dateReserved": "2022-06-29T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:52:26.030Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}