Search

Find a vulnerability

Search criteria

    28 vulnerabilities found for rx3 by tenda

    CVE-2026-2187 (GCVE-0-2026-2187)

    Vulnerability from nvd – Published: 2026-02-08 21:02 – Updated: 2026-02-23 09:49
    VLAI
    Title
    Tenda RX3 formSetQosBand set_qosMib_list stack-based overflow
    Summary
    A vulnerability was found in Tenda RX3 16.03.13.11. The affected element is the function set_qosMib_list of the file /goform/formSetQosBand. Performing a manipulation of the argument list results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-09 20:53 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344890 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344890 signaturepermissions-required
    https://vuldb.com/?submit.749721 third-party-advisory
    https://github.com/LX-66-LX/cve-new/issues/8 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2187",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T20:53:56.388298Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T20:54:20.290Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LX-66-LX (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda RX3 16.03.13.11. The affected element is the function set_qosMib_list of the file /goform/formSetQosBand. Performing a manipulation of the argument list results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:49:51.970Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344890 | Tenda RX3 formSetQosBand set_qosMib_list stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344890"
            },
            {
              "name": "VDB-344890 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344890"
            },
            {
              "name": "Submit #749721 | Tenda RX3 V16.03.13.11 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749721"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/LX-66-LX/cve-new/issues/8"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T01:15:32.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 formSetQosBand set_qosMib_list stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2187",
        "datePublished": "2026-02-08T21:02:11.500Z",
        "dateReserved": "2026-02-07T17:16:30.200Z",
        "dateUpdated": "2026-02-23T09:49:51.970Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2186 (GCVE-0-2026-2186)

    Vulnerability from nvd – Published: 2026-02-08 21:02 – Updated: 2026-02-23 09:49
    VLAI
    Title
    Tenda RX3 SetIpMacBind fromSetIpMacBind stack-based overflow
    Summary
    A vulnerability has been found in Tenda RX3 16.03.13.11. Impacted is the function fromSetIpMacBind of the file /goform/SetIpMacBind. Such manipulation of the argument list leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-09 21:08 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344889 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344889 signaturepermissions-required
    https://vuldb.com/?submit.749718 third-party-advisory
    https://github.com/LX-66-LX/cve-new/issues/7 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2186",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T21:08:17.361623Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T21:08:28.920Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LX-66-LX (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda RX3 16.03.13.11. Impacted is the function fromSetIpMacBind of the file /goform/SetIpMacBind. Such manipulation of the argument list leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:49:37.836Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344889 | Tenda RX3 SetIpMacBind fromSetIpMacBind stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344889"
            },
            {
              "name": "VDB-344889 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344889"
            },
            {
              "name": "Submit #749718 | Tenda RX3 V16.03.13.11 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749718"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/LX-66-LX/cve-new/issues/7"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T01:15:32.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 SetIpMacBind fromSetIpMacBind stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2186",
        "datePublished": "2026-02-08T21:02:08.184Z",
        "dateReserved": "2026-02-07T17:16:24.891Z",
        "dateUpdated": "2026-02-23T09:49:37.836Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2185 (GCVE-0-2026-2185)

    Vulnerability from nvd – Published: 2026-02-08 20:32 – Updated: 2026-02-23 09:49
    VLAI
    Title
    Tenda RX3 MAC Filtering Configuration Endpoint setBlackRule set_device_name stack-based overflow
    Summary
    A flaw has been found in Tenda RX3 16.03.13.11. This issue affects the function set_device_name of the file /goform/setBlackRule of the component MAC Filtering Configuration Endpoint. This manipulation of the argument devName/mac causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-09 21:07 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344888 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344888 signaturepermissions-required
    https://vuldb.com/?submit.749715 third-party-advisory
    https://github.com/LX-66-LX/cve-new/issues/6 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2185",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T21:07:48.682740Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T21:07:57.607Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "MAC Filtering Configuration Endpoint"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LX-66-LX (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda RX3 16.03.13.11. This issue affects the function set_device_name of the file /goform/setBlackRule of the component MAC Filtering Configuration Endpoint. This manipulation of the argument devName/mac causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:49:21.723Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344888 | Tenda RX3 MAC Filtering Configuration Endpoint setBlackRule set_device_name stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344888"
            },
            {
              "name": "VDB-344888 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344888"
            },
            {
              "name": "Submit #749715 | Tenda RX3 V16.03.13.11 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749715"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/LX-66-LX/cve-new/issues/6"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T01:15:32.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 MAC Filtering Configuration Endpoint setBlackRule set_device_name stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2185",
        "datePublished": "2026-02-08T20:32:09.908Z",
        "dateReserved": "2026-02-07T15:29:25.365Z",
        "dateUpdated": "2026-02-23T09:49:21.723Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2181 (GCVE-0-2026-2181)

    Vulnerability from nvd – Published: 2026-02-08 19:32 – Updated: 2026-02-23 09:48
    VLAI
    Title
    Tenda RX3 openSchedWifi stack-based overflow
    Summary
    A security flaw has been discovered in Tenda RX3 16.03.13.11. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-09 17:09 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344884 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344884 signaturepermissions-required
    https://vuldb.com/?submit.749710 third-party-advisory
    https://github.com/LX-66-LX/cve-new/issues/5 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2181",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T17:09:12.760893Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T17:09:29.582Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LX-66-LX (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda RX3 16.03.13.11. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:48:28.958Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344884 | Tenda RX3 openSchedWifi stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344884"
            },
            {
              "name": "VDB-344884 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344884"
            },
            {
              "name": "Submit #749710 | Tenda RX3 V16.03.13.11 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749710"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/LX-66-LX/cve-new/issues/5"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T01:15:33.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 openSchedWifi stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2181",
        "datePublished": "2026-02-08T19:32:13.684Z",
        "dateReserved": "2026-02-07T15:19:17.004Z",
        "dateUpdated": "2026-02-23T09:48:28.958Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2180 (GCVE-0-2026-2180)

    Vulnerability from nvd – Published: 2026-02-08 19:32 – Updated: 2026-02-23 09:48
    VLAI
    Title
    Tenda RX3 fast_setting_wifi_set stack-based overflow
    Summary
    A vulnerability was identified in Tenda RX3 16.03.13.11. Affected is an unknown function of the file /goform/fast_setting_wifi_set. Such manipulation of the argument ssid_5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-09 17:10 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344883 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344883 signaturepermissions-required
    https://vuldb.com/?submit.749703 third-party-advisory
    https://github.com/LX-66-LX/cve-new/issues/4 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2180",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T17:10:04.977397Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T17:12:13.986Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LX-66-LX (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda RX3 16.03.13.11. Affected is an unknown function of the file /goform/fast_setting_wifi_set. Such manipulation of the argument ssid_5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:48:12.741Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344883 | Tenda RX3 fast_setting_wifi_set stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344883"
            },
            {
              "name": "VDB-344883 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344883"
            },
            {
              "name": "Submit #749703 | Tenda  RX3  V16.03.13.11 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749703"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/LX-66-LX/cve-new/issues/4"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T01:15:33.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 fast_setting_wifi_set stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2180",
        "datePublished": "2026-02-08T19:32:10.881Z",
        "dateReserved": "2026-02-07T15:19:12.136Z",
        "dateUpdated": "2026-02-23T09:48:12.741Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-5527 (GCVE-0-2025-5527)

    Vulnerability from nvd – Published: 2025-06-03 20:31 – Updated: 2025-06-04 13:55
    VLAI
    Title
    Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow
    Summary
    A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-04 13:55 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.310967 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.310967 signaturepermissions-required
    https://vuldb.com/?submit.586781 third-party-advisory
    https://github.com/alc9700jmo/CVE/issues/13 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi_TDE01
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5527",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-04T13:55:13.106941Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-04T13:55:16.897Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/alc9700jmo/CVE/issues/13"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi_TDE01"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "alc9700 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11_multi_TDE01 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion save_staticroute_data der Datei /goform/SetStaticRouteCfg. Durch Manipulieren des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-03T20:31:06.838Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-310967 | Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.310967"
            },
            {
              "name": "VDB-310967 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.310967"
            },
            {
              "name": "Submit #586781 | Shenzhen Tenda Technology Co., Ltd. Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.586781"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/alc9700jmo/CVE/issues/13"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-03T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-03T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-03T15:16:45.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5527",
        "datePublished": "2025-06-03T20:31:06.838Z",
        "dateReserved": "2025-06-03T13:11:39.939Z",
        "dateUpdated": "2025-06-04T13:55:16.897Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-4357 (GCVE-0-2025-4357)

    Vulnerability from nvd – Published: 2025-05-06 13:31 – Updated: 2025-05-06 14:39
    VLAI
    Title
    Tenda RX3 telnet command injection
    Summary
    A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-06 14:39 UTC
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-4357",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-06T14:39:31.762587Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-06T14:39:36.483Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/RX3_telnetd/rx3_telnetd.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "duojie_0x00 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11_multi ausgemacht. Sie wurde als kritisch eingestuft. Davon betroffen ist unbekannter Code der Datei /goform/telnet. Durch die Manipulation mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5.8,
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-06T13:31:07.818Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-307475 | Tenda RX3 telnet command injection",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.307475"
            },
            {
              "name": "VDB-307475 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.307475"
            },
            {
              "name": "Submit #564727 | Tenda RX3 V16.03.13.11_multi  Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.564727"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/RX3_telnetd/rx3_telnetd.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-05-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-05-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-05-05T19:16:33.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 telnet command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-4357",
        "datePublished": "2025-05-06T13:31:07.818Z",
        "dateReserved": "2025-05-05T17:11:30.503Z",
        "dateUpdated": "2025-05-06T14:39:36.483Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3259 (GCVE-0-2025-3259)

    Vulnerability from nvd – Published: 2025-04-04 17:31 – Updated: 2025-04-04 18:55
    VLAI
    Title
    Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow
    Summary
    A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-04 18:55 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3259",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-04T18:55:13.505001Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-04T18:55:17.132Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://sixth-action-50e.notion.site/Tenda-RX3-Buffer-Overflow-1c9f6468377380a2977cd6c3a81f453c"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "syuvi (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11 entdeckt. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Durch Manipulation des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-04T17:31:06.694Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-303329 | Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.303329"
            },
            {
              "name": "VDB-303329 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.303329"
            },
            {
              "name": "Submit #549199 | Tenda RX3 RX3 Firmware V16.03.13.11_multi Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.549199"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://sixth-action-50e.notion.site/Tenda-RX3-Buffer-Overflow-1c9f6468377380a2977cd6c3a81f453c?pvs=4"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-04-04T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-04-04T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-04-04T09:51:50.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-3259",
        "datePublished": "2025-04-04T17:31:06.694Z",
        "dateReserved": "2025-04-04T07:46:47.401Z",
        "dateUpdated": "2025-04-04T18:55:17.132Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-2187 (GCVE-0-2026-2187)

    Vulnerability from cvelistv5 – Published: 2026-02-08 21:02 – Updated: 2026-02-23 09:49
    VLAI
    Title
    Tenda RX3 formSetQosBand set_qosMib_list stack-based overflow
    Summary
    A vulnerability was found in Tenda RX3 16.03.13.11. The affected element is the function set_qosMib_list of the file /goform/formSetQosBand. Performing a manipulation of the argument list results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-09 20:53 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344890 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344890 signaturepermissions-required
    https://vuldb.com/?submit.749721 third-party-advisory
    https://github.com/LX-66-LX/cve-new/issues/8 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2187",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T20:53:56.388298Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T20:54:20.290Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LX-66-LX (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda RX3 16.03.13.11. The affected element is the function set_qosMib_list of the file /goform/formSetQosBand. Performing a manipulation of the argument list results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:49:51.970Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344890 | Tenda RX3 formSetQosBand set_qosMib_list stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344890"
            },
            {
              "name": "VDB-344890 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344890"
            },
            {
              "name": "Submit #749721 | Tenda RX3 V16.03.13.11 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749721"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/LX-66-LX/cve-new/issues/8"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T01:15:32.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 formSetQosBand set_qosMib_list stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2187",
        "datePublished": "2026-02-08T21:02:11.500Z",
        "dateReserved": "2026-02-07T17:16:30.200Z",
        "dateUpdated": "2026-02-23T09:49:51.970Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2186 (GCVE-0-2026-2186)

    Vulnerability from cvelistv5 – Published: 2026-02-08 21:02 – Updated: 2026-02-23 09:49
    VLAI
    Title
    Tenda RX3 SetIpMacBind fromSetIpMacBind stack-based overflow
    Summary
    A vulnerability has been found in Tenda RX3 16.03.13.11. Impacted is the function fromSetIpMacBind of the file /goform/SetIpMacBind. Such manipulation of the argument list leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-09 21:08 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344889 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344889 signaturepermissions-required
    https://vuldb.com/?submit.749718 third-party-advisory
    https://github.com/LX-66-LX/cve-new/issues/7 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2186",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T21:08:17.361623Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T21:08:28.920Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LX-66-LX (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda RX3 16.03.13.11. Impacted is the function fromSetIpMacBind of the file /goform/SetIpMacBind. Such manipulation of the argument list leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:49:37.836Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344889 | Tenda RX3 SetIpMacBind fromSetIpMacBind stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344889"
            },
            {
              "name": "VDB-344889 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344889"
            },
            {
              "name": "Submit #749718 | Tenda RX3 V16.03.13.11 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749718"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/LX-66-LX/cve-new/issues/7"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T01:15:32.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 SetIpMacBind fromSetIpMacBind stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2186",
        "datePublished": "2026-02-08T21:02:08.184Z",
        "dateReserved": "2026-02-07T17:16:24.891Z",
        "dateUpdated": "2026-02-23T09:49:37.836Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2185 (GCVE-0-2026-2185)

    Vulnerability from cvelistv5 – Published: 2026-02-08 20:32 – Updated: 2026-02-23 09:49
    VLAI
    Title
    Tenda RX3 MAC Filtering Configuration Endpoint setBlackRule set_device_name stack-based overflow
    Summary
    A flaw has been found in Tenda RX3 16.03.13.11. This issue affects the function set_device_name of the file /goform/setBlackRule of the component MAC Filtering Configuration Endpoint. This manipulation of the argument devName/mac causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-09 21:07 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344888 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344888 signaturepermissions-required
    https://vuldb.com/?submit.749715 third-party-advisory
    https://github.com/LX-66-LX/cve-new/issues/6 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2185",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T21:07:48.682740Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T21:07:57.607Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "MAC Filtering Configuration Endpoint"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LX-66-LX (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda RX3 16.03.13.11. This issue affects the function set_device_name of the file /goform/setBlackRule of the component MAC Filtering Configuration Endpoint. This manipulation of the argument devName/mac causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:49:21.723Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344888 | Tenda RX3 MAC Filtering Configuration Endpoint setBlackRule set_device_name stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344888"
            },
            {
              "name": "VDB-344888 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344888"
            },
            {
              "name": "Submit #749715 | Tenda RX3 V16.03.13.11 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749715"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/LX-66-LX/cve-new/issues/6"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T01:15:32.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 MAC Filtering Configuration Endpoint setBlackRule set_device_name stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2185",
        "datePublished": "2026-02-08T20:32:09.908Z",
        "dateReserved": "2026-02-07T15:29:25.365Z",
        "dateUpdated": "2026-02-23T09:49:21.723Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2181 (GCVE-0-2026-2181)

    Vulnerability from cvelistv5 – Published: 2026-02-08 19:32 – Updated: 2026-02-23 09:48
    VLAI
    Title
    Tenda RX3 openSchedWifi stack-based overflow
    Summary
    A security flaw has been discovered in Tenda RX3 16.03.13.11. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-09 17:09 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344884 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344884 signaturepermissions-required
    https://vuldb.com/?submit.749710 third-party-advisory
    https://github.com/LX-66-LX/cve-new/issues/5 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2181",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T17:09:12.760893Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T17:09:29.582Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LX-66-LX (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Tenda RX3 16.03.13.11. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:48:28.958Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344884 | Tenda RX3 openSchedWifi stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344884"
            },
            {
              "name": "VDB-344884 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344884"
            },
            {
              "name": "Submit #749710 | Tenda RX3 V16.03.13.11 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749710"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/LX-66-LX/cve-new/issues/5"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T01:15:33.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 openSchedWifi stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2181",
        "datePublished": "2026-02-08T19:32:13.684Z",
        "dateReserved": "2026-02-07T15:19:17.004Z",
        "dateUpdated": "2026-02-23T09:48:28.958Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2180 (GCVE-0-2026-2180)

    Vulnerability from cvelistv5 – Published: 2026-02-08 19:32 – Updated: 2026-02-23 09:48
    VLAI
    Title
    Tenda RX3 fast_setting_wifi_set stack-based overflow
    Summary
    A vulnerability was identified in Tenda RX3 16.03.13.11. Affected is an unknown function of the file /goform/fast_setting_wifi_set. Such manipulation of the argument ssid_5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-09 17:10 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.344883 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.344883 signaturepermissions-required
    https://vuldb.com/?submit.749703 third-party-advisory
    https://github.com/LX-66-LX/cve-new/issues/4 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
        cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2180",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-09T17:10:04.977397Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-09T17:12:13.986Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:rx3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "LX-66-LX (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda RX3 16.03.13.11. Affected is an unknown function of the file /goform/fast_setting_wifi_set. Such manipulation of the argument ssid_5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:48:12.741Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-344883 | Tenda RX3 fast_setting_wifi_set stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.344883"
            },
            {
              "name": "VDB-344883 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.344883"
            },
            {
              "name": "Submit #749703 | Tenda  RX3  V16.03.13.11 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.749703"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/LX-66-LX/cve-new/issues/4"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-07T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-09T01:15:33.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 fast_setting_wifi_set stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2180",
        "datePublished": "2026-02-08T19:32:10.881Z",
        "dateReserved": "2026-02-07T15:19:12.136Z",
        "dateUpdated": "2026-02-23T09:48:12.741Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-5527 (GCVE-0-2025-5527)

    Vulnerability from cvelistv5 – Published: 2025-06-03 20:31 – Updated: 2025-06-04 13:55
    VLAI
    Title
    Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow
    Summary
    A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-04 13:55 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.310967 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.310967 signaturepermissions-required
    https://vuldb.com/?submit.586781 third-party-advisory
    https://github.com/alc9700jmo/CVE/issues/13 exploitissue-tracking
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi_TDE01
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5527",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-04T13:55:13.106941Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-04T13:55:16.897Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/alc9700jmo/CVE/issues/13"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi_TDE01"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "alc9700 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11_multi_TDE01 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion save_staticroute_data der Datei /goform/SetStaticRouteCfg. Durch Manipulieren des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-03T20:31:06.838Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-310967 | Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.310967"
            },
            {
              "name": "VDB-310967 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.310967"
            },
            {
              "name": "Submit #586781 | Shenzhen Tenda Technology Co., Ltd. Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.586781"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/alc9700jmo/CVE/issues/13"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-03T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-03T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-03T15:16:45.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5527",
        "datePublished": "2025-06-03T20:31:06.838Z",
        "dateReserved": "2025-06-03T13:11:39.939Z",
        "dateUpdated": "2025-06-04T13:55:16.897Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-4357 (GCVE-0-2025-4357)

    Vulnerability from cvelistv5 – Published: 2025-05-06 13:31 – Updated: 2025-05-06 14:39
    VLAI
    Title
    Tenda RX3 telnet command injection
    Summary
    A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-06 14:39 UTC
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11_multi
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-4357",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-06T14:39:31.762587Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-06T14:39:36.483Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/RX3_telnetd/rx3_telnetd.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11_multi"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "duojie_0x00 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11_multi ausgemacht. Sie wurde als kritisch eingestuft. Davon betroffen ist unbekannter Code der Datei /goform/telnet. Durch die Manipulation mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5.8,
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-06T13:31:07.818Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-307475 | Tenda RX3 telnet command injection",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.307475"
            },
            {
              "name": "VDB-307475 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.307475"
            },
            {
              "name": "Submit #564727 | Tenda RX3 V16.03.13.11_multi  Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.564727"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/RX3_telnetd/rx3_telnetd.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-05-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-05-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-05-05T19:16:33.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 telnet command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-4357",
        "datePublished": "2025-05-06T13:31:07.818Z",
        "dateReserved": "2025-05-05T17:11:30.503Z",
        "dateUpdated": "2025-05-06T14:39:36.483Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3259 (GCVE-0-2025-3259)

    Vulnerability from cvelistv5 – Published: 2025-04-04 17:31 – Updated: 2025-04-04 18:55
    VLAI
    Title
    Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow
    Summary
    A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-04 18:55 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda RX3 Affected: 16.03.13.11
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3259",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-04T18:55:13.505001Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-04T18:55:17.132Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://sixth-action-50e.notion.site/Tenda-RX3-Buffer-Overflow-1c9f6468377380a2977cd6c3a81f453c"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RX3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "16.03.13.11"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "syuvi (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda RX3 16.03.13.11 entdeckt. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Durch Manipulation des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-04T17:31:06.694Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-303329 | Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.303329"
            },
            {
              "name": "VDB-303329 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.303329"
            },
            {
              "name": "Submit #549199 | Tenda RX3 RX3 Firmware V16.03.13.11_multi Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.549199"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://sixth-action-50e.notion.site/Tenda-RX3-Buffer-Overflow-1c9f6468377380a2977cd6c3a81f453c?pvs=4"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-04-04T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-04-04T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-04-04T09:51:50.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-3259",
        "datePublished": "2025-04-04T17:31:06.694Z",
        "dateReserved": "2025-04-04T07:46:47.401Z",
        "dateUpdated": "2025-04-04T18:55:17.132Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    VAR-202503-1031

    Vulnerability from variot - Updated: 2025-08-25 23:38

    Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the list parameter at /goform/SetVirtualServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a home wireless router from China's Tenda company

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-1031",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi_tde01"
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi tde01"
          },
          {
            "model": "rx3 v16.03.13.11 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09161"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002955"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29361"
          }
        ]
      },
      "cve": "CVE-2025-29361",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09161",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29361",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-002955",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29361",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-002955",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09161",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09161"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002955"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29361"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the list parameter at /goform/SetVirtualServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a home wireless router from China\u0027s Tenda company",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29361"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002955"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09161"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29361",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002955",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09161",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09161"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002955"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29361"
          }
        ]
      },
      "id": "VAR-202503-1031",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09161"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09161"
          }
        ]
      },
      "last_update_date": "2025-08-25T23:38:44.475000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002955"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29361"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/2664521593/mycve/blob/main/tenda/rx3/tenda_rx3_bof_5.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29361"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09161"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002955"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29361"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09161"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002955"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29361"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09161"
          },
          {
            "date": "2025-04-04T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002955"
          },
          {
            "date": "2025-03-13T14:15:36.833000",
            "db": "NVD",
            "id": "CVE-2025-29361"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-07T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09161"
          },
          {
            "date": "2025-04-04T06:30:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002955"
          },
          {
            "date": "2025-08-25T02:14:40.157000",
            "db": "NVD",
            "id": "CVE-2025-29361"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda\u00a0 of \u00a0RX3\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002955"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-0082

    Vulnerability from variot - Updated: 2025-08-25 23:33

    A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Tenda of RX3 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda RX3 is a dual-band WiFi 6 home wireless router from China's Tenda company. It is used for home network coverage and supports high-speed wireless connection.

    Tenda RX3 has a command injection vulnerability, which is caused by the file /goform/telnet failing to properly filter special characters and commands in the construction command. No detailed vulnerability details are currently provided

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-0082",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi"
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi"
          },
          {
            "model": "rx3 16.03.13.11 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10598"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005033"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4357"
          }
        ]
      },
      "cve": "CVE-2025-4357",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "MULTIPLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.4,
                "id": "CVE-2025-4357",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Multiple",
                "author": "OTHER",
                "availabilityImpact": "Partial",
                "baseScore": 5.8,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-005033",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "MULTIPLE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.4,
                "id": "CNVD-2025-10598",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.2,
                "id": "CVE-2025-4357",
                "impactScore": 3.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-4357",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-005033",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-4357",
                "trust": 1.0,
                "value": "Medium"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-4357",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-005033",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-10598",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10598"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005033"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4357"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4357"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Tenda of RX3 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda RX3 is a dual-band WiFi 6 home wireless router from China\u0027s Tenda company. It is used for home network coverage and supports high-speed wireless connection. \n\nTenda RX3 has a command injection vulnerability, which is caused by the file /goform/telnet failing to properly filter special characters and commands in the construction command. No detailed vulnerability details are currently provided",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-4357"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005033"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10598"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-4357",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "307475",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005033",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10598",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10598"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005033"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4357"
          }
        ]
      },
      "id": "VAR-202505-0082",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10598"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10598"
          }
        ]
      },
      "last_update_date": "2025-08-25T23:33:34.805000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-74",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "injection (CWE-74) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Command injection (CWE-77) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005033"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4357"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?submit.564727"
          },
          {
            "trust": 1.8,
            "url": "https://github.com/ghostsuzhijian/iot-/blob/main/rx3_telnetd/rx3_telnetd.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.307475"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.307475"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-4357"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10598"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005033"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4357"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10598"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005033"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4357"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10598"
          },
          {
            "date": "2025-05-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005033"
          },
          {
            "date": "2025-05-06T14:15:42.287000",
            "db": "NVD",
            "id": "CVE-2025-4357"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-26T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10598"
          },
          {
            "date": "2025-05-15T06:54:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005033"
          },
          {
            "date": "2025-08-25T02:14:14.280000",
            "db": "NVD",
            "id": "CVE-2025-4357"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda\u00a0 of \u00a0RX3\u00a0 Command injection vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005033"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-1941

    Vulnerability from variot - Updated: 2025-08-25 23:24

    Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to buffer overflow via the schedStartTime and schedEndTime parameters at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a dual-band WiFi home wireless router from China's Tenda Company

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-1941",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi_tde01"
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi tde01"
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3 v16.03.13.11 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08318"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003203"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29363"
          }
        ]
      },
      "cve": "CVE-2025-29363",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-08318",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29363",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-003203",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29363",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-003203",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-08318",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08318"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003203"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29363"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to buffer overflow via the schedStartTime and schedEndTime parameters at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a dual-band WiFi home wireless router from China\u0027s Tenda Company",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29363"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003203"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08318"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29363",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003203",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08318",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08318"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003203"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29363"
          }
        ]
      },
      "id": "VAR-202503-1941",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08318"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08318"
          }
        ]
      },
      "last_update_date": "2025-08-25T23:24:35.101000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003203"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29363"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/2664521593/mycve/blob/main/tenda/rx3/tenda_rx3_bof_7.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29363"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08318"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003203"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29363"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08318"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003203"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29363"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-24T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08318"
          },
          {
            "date": "2025-04-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003203"
          },
          {
            "date": "2025-03-13T14:15:37.103000",
            "db": "NVD",
            "id": "CVE-2025-29363"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08318"
          },
          {
            "date": "2025-04-11T01:46:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003203"
          },
          {
            "date": "2025-08-25T02:14:28.467000",
            "db": "NVD",
            "id": "CVE-2025-29363"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda\u00a0 of \u00a0RX3\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003203"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-2140

    Vulnerability from variot - Updated: 2025-08-25 23:18

    Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the list parameter at /goform/setPptpUserList. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a dual-band WiFi 6 home wireless router from China's Tenda Company

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-2140",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi_tde01"
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi tde01"
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3 v16.03.13.11 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-06059"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003202"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29362"
          }
        ]
      },
      "cve": "CVE-2025-29362",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-06059",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29362",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-003202",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29362",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-003202",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-06059",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-06059"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003202"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29362"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the list parameter at /goform/setPptpUserList. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a dual-band WiFi 6 home wireless router from China\u0027s Tenda Company",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29362"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003202"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-06059"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29362",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003202",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-06059",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-06059"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003202"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29362"
          }
        ]
      },
      "id": "VAR-202503-2140",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-06059"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-06059"
          }
        ]
      },
      "last_update_date": "2025-08-25T23:18:53.306000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda RX3 /goform/setPptpUserList buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/673421"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-06059"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003202"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29362"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/2664521593/mycve/blob/main/tenda/rx3/tenda_rx3_bof_3.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29362"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-06059"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003202"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29362"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-06059"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003202"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29362"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-03-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-06059"
          },
          {
            "date": "2025-04-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003202"
          },
          {
            "date": "2025-03-13T14:15:36.963000",
            "db": "NVD",
            "id": "CVE-2025-29362"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-03-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-06059"
          },
          {
            "date": "2025-04-11T01:44:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003202"
          },
          {
            "date": "2025-08-25T02:14:33.363000",
            "db": "NVD",
            "id": "CVE-2025-29362"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda\u00a0 of \u00a0RX3\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003202"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-1032

    Vulnerability from variot - Updated: 2025-08-01 23:22

    Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the firewallEn parameter at /goform/SetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a dual-band WiFi 6 home wireless router from China's Tenda company. It is used for home network coverage and supports high-speed wireless connections. The vulnerability is caused by the firewallEn parameter in /goform/SetFirewallCfg failing to correctly verify the length of the input data

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-1032",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi_tde01"
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi tde01"
          },
          {
            "model": "rx3 v16.03.13.11 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08316"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003810"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29358"
          }
        ]
      },
      "cve": "CVE-2025-29358",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-08316",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29358",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-003810",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29358",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-003810",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-08316",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08316"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003810"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29358"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the firewallEn parameter at /goform/SetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a dual-band WiFi 6 home wireless router from China\u0027s Tenda company. It is used for home network coverage and supports high-speed wireless connections. The vulnerability is caused by the firewallEn parameter in /goform/SetFirewallCfg failing to correctly verify the length of the input data",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29358"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003810"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08316"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29358",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003810",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08316",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08316"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003810"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29358"
          }
        ]
      },
      "id": "VAR-202503-1032",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08316"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08316"
          }
        ]
      },
      "last_update_date": "2025-08-01T23:22:03.384000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003810"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29358"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/2664521593/mycve/blob/main/tenda/rx3/tenda_rx3_bof_2.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29358"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08316"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003810"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29358"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08316"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003810"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29358"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08316"
          },
          {
            "date": "2025-04-22T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003810"
          },
          {
            "date": "2025-03-13T14:15:36.407000",
            "db": "NVD",
            "id": "CVE-2025-29358"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08316"
          },
          {
            "date": "2025-04-22T08:42:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003810"
          },
          {
            "date": "2025-08-01T02:15:27.360000",
            "db": "NVD",
            "id": "CVE-2025-29358"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda\u00a0 of \u00a0RX3\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003810"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0851

    Vulnerability from variot - Updated: 2025-08-01 23:19

    Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the deviceId parameter at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a home wireless router from China's Tenda company

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0851",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi_tde01"
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi tde01"
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3 v16.03.13.11 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09163"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003189"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29359"
          }
        ]
      },
      "cve": "CVE-2025-29359",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09163",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29359",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-003189",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29359",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-003189",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09163",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09163"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003189"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29359"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the deviceId parameter at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a home wireless router from China\u0027s Tenda company",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29359"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003189"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09163"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29359",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003189",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09163",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09163"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003189"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29359"
          }
        ]
      },
      "id": "VAR-202503-0851",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09163"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09163"
          }
        ]
      },
      "last_update_date": "2025-08-01T23:19:30.212000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003189"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29359"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/2664521593/mycve/blob/main/tenda/rx3/tenda_rx3_bof_6.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29359"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09163"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003189"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29359"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09163"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003189"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29359"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09163"
          },
          {
            "date": "2025-04-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003189"
          },
          {
            "date": "2025-03-13T14:15:36.547000",
            "db": "NVD",
            "id": "CVE-2025-29359"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-07T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09163"
          },
          {
            "date": "2025-04-11T01:43:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003189"
          },
          {
            "date": "2025-08-01T02:15:40.560000",
            "db": "NVD",
            "id": "CVE-2025-29359"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda\u00a0 of \u00a0RX3\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003189"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0683

    Vulnerability from variot - Updated: 2025-08-01 23:14

    Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the time and timeZone parameters at /goform/SetSysTimeCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a home wireless router from China's Tenda company

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0683",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi_tde01"
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi tde01"
          },
          {
            "model": "rx3 v16.03.13.11 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09162"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003812"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29360"
          }
        ]
      },
      "cve": "CVE-2025-29360",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09162",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29360",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-003812",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29360",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-003812",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09162",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09162"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003812"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29360"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the time and timeZone parameters at /goform/SetSysTimeCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda RX3 is a home wireless router from China\u0027s Tenda company",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29360"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003812"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09162"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29360",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003812",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09162",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09162"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003812"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29360"
          }
        ]
      },
      "id": "VAR-202503-0683",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09162"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09162"
          }
        ]
      },
      "last_update_date": "2025-08-01T23:14:47.157000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003812"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29360"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/2664521593/mycve/blob/main/tenda/rx3/tenda_rx3_bof_1.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29360"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09162"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003812"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29360"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09162"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003812"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29360"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09162"
          },
          {
            "date": "2025-04-22T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003812"
          },
          {
            "date": "2025-03-13T14:15:36.690000",
            "db": "NVD",
            "id": "CVE-2025-29360"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-07T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09162"
          },
          {
            "date": "2025-04-22T08:44:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003812"
          },
          {
            "date": "2025-08-01T02:15:49.250000",
            "db": "NVD",
            "id": "CVE-2025-29360"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda\u00a0 of \u00a0RX3\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003812"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-2141

    Vulnerability from variot - Updated: 2025-08-01 23:13

    Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the startIp and endIp parameters at /goform/SetPptpServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda of RX3 A vulnerability exists in firmware related to improper shutdown and release of resources.Service operation interruption (DoS) It may be in a state. Tenda RX3 is a dual-band WiFi 6 home wireless router from China's Tenda company. It is used for home network coverage and supports high-speed wireless connections. The vulnerability is caused by the startIp and endIp parameters in /goform/SetPptpServerCfg failing to correctly verify the length of the input data

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-2141",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi_tde01"
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi tde01"
          },
          {
            "model": "rx3 v16.03.13.11 multi",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08317"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002956"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29357"
          }
        ]
      },
      "cve": "CVE-2025-29357",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-08317",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29357",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-002956",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29357",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-002956",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-08317",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08317"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002956"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29357"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda RX3 US_RX3V1.0br_V16.03.13.11_multi_TDE01 is vulnerable to Buffer Overflow via the startIp and endIp parameters at /goform/SetPptpServerCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted packet. Tenda of RX3 A vulnerability exists in firmware related to improper shutdown and release of resources.Service operation interruption (DoS) It may be in a state. Tenda RX3 is a dual-band WiFi 6 home wireless router from China\u0027s Tenda company. It is used for home network coverage and supports high-speed wireless connections. The vulnerability is caused by the startIp and endIp parameters in /goform/SetPptpServerCfg failing to correctly verify the length of the input data",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29357"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002956"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08317"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29357",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002956",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08317",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08317"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002956"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29357"
          }
        ]
      },
      "id": "VAR-202503-2141",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08317"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08317"
          }
        ]
      },
      "last_update_date": "2025-08-01T23:13:09.589000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-404",
            "trust": 1.0
          },
          {
            "problemtype": "Improper shutdown and release of resources (CWE-404) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002956"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29357"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/2664521593/mycve/blob/main/tenda/rx3/tenda_rx3_bof_4.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29357"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08317"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002956"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29357"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08317"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002956"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29357"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08317"
          },
          {
            "date": "2025-04-04T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002956"
          },
          {
            "date": "2025-03-13T14:15:36.253000",
            "db": "NVD",
            "id": "CVE-2025-29357"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08317"
          },
          {
            "date": "2025-04-04T06:30:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002956"
          },
          {
            "date": "2025-08-01T02:15:17.473000",
            "db": "NVD",
            "id": "CVE-2025-29357"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda\u00a0 of \u00a0RX3\u00a0 Improper Shutdown and Release of Resources in Firmware Vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002956"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202506-0269

    Vulnerability from variot - Updated: 2025-06-15 23:36

    A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. of RX3 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda RX3 is a dual-band WiFi 6 home wireless router from China's Tenda company. It is used for home network coverage and supports high-speed wireless connections. The vulnerability is caused by the parameter list in the file /goform/SetStaticRouteCfg failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202506-0269",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi"
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi"
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3 16.03.13.11 multi tde01",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12341"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006542"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5527"
          }
        ]
      },
      "cve": "CVE-2025-5527",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-5527",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006542",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-12341",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-5527",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006542",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-5527",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006542",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-12341",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12341"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006542"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5527"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. of RX3 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda RX3 is a dual-band WiFi 6 home wireless router from China\u0027s Tenda company. It is used for home network coverage and supports high-speed wireless connections. The vulnerability is caused by the parameter list in the file /goform/SetStaticRouteCfg failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-5527"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006542"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-12341"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-5527",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "310967",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006542",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-12341",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12341"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006542"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5527"
          }
        ]
      },
      "id": "VAR-202506-0269",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12341"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12341"
          }
        ]
      },
      "last_update_date": "2025-06-15T23:36:07.474000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006542"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5527"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/alc9700jmo/cve/issues/13"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.310967"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.586781"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-5527"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.310967"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12341"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006542"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5527"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12341"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006542"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5527"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-12341"
          },
          {
            "date": "2025-06-10T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006542"
          },
          {
            "date": "2025-06-03T21:15:23.483000",
            "db": "NVD",
            "id": "CVE-2025-5527"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-12341"
          },
          {
            "date": "2025-06-10T02:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006542"
          },
          {
            "date": "2025-06-09T15:11:48.217000",
            "db": "NVD",
            "id": "CVE-2025-5527"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0RX3\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006542"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-1109

    Vulnerability from variot - Updated: 2025-06-06 23:32

    There is a stack overflow vulnerability in Tenda RX3 V1.0br_V16.03.13.11 In the fromSetWifiGusetBasic function of the web url /goform/ WifiGuestSet, the manipulation of the parameter shareSpeed leads to stack overflow. Shenzhen Tenda Technology Co.,Ltd. of RX3 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can use this vulnerability to submit special requests to crash the application and cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-1109",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi"
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi"
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3 v1.0br v16.03.13.11",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09665"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006233"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44899"
          }
        ]
      },
      "cve": "CVE-2025-44899",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09665",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-44899",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006233",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-44899",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006233",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09665",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09665"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006233"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44899"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "There is a stack overflow vulnerability in Tenda RX3 V1.0br_V16.03.13.11 In the fromSetWifiGusetBasic function of the web url /goform/ WifiGuestSet, the manipulation of the parameter shareSpeed leads to stack overflow. Shenzhen Tenda Technology Co.,Ltd. of RX3 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can use this vulnerability to submit special requests to crash the application and cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-44899"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006233"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09665"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-44899",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006233",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09665",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09665"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006233"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44899"
          }
        ]
      },
      "id": "VAR-202505-1109",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09665"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09665"
          }
        ]
      },
      "last_update_date": "2025-06-06T23:32:41.699000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006233"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44899"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/faqiadegege/iotvuln/blob/main/tenda_rx3_fromsetwifigusetbasic_sharespeed_overflow/detail.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-44899"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09665"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006233"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44899"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09665"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006233"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44899"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09665"
          },
          {
            "date": "2025-06-05T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006233"
          },
          {
            "date": "2025-05-06T21:16:19.177000",
            "db": "NVD",
            "id": "CVE-2025-44899"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09665"
          },
          {
            "date": "2025-06-05T01:31:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006233"
          },
          {
            "date": "2025-06-04T17:25:44.830000",
            "db": "NVD",
            "id": "CVE-2025-44899"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0RX3\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006233"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-0403

    Vulnerability from variot - Updated: 2025-06-06 23:07

    In Tenda RX3 V1.0br_V16.03.13.11 in the GetParentControlInfo function of the web url /goform/GetParentControlInfo, the manipulation of the parameter mac leads to stack overflow. Shenzhen Tenda Technology Co.,Ltd. of RX3 A stack-based buffer overflow vulnerability exists in the firmware.Information may be obtained and information may be tampered with. No detailed vulnerability details are currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-0403",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi"
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi"
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3 v1.0br v16.03.13.11",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09664"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006276"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44900"
          }
        ]
      },
      "cve": "CVE-2025-44900",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-09664",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-44900",
                "impactScore": 2.5,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "None",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006276",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-44900",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006276",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09664",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09664"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006276"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44900"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "In Tenda RX3 V1.0br_V16.03.13.11 in the GetParentControlInfo function of the web url /goform/GetParentControlInfo, the manipulation of the parameter mac leads to stack overflow. Shenzhen Tenda Technology Co.,Ltd. of RX3 A stack-based buffer overflow vulnerability exists in the firmware.Information may be obtained and information may be tampered with. No detailed vulnerability details are currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-44900"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006276"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09664"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-44900",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006276",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09664",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09664"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006276"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44900"
          }
        ]
      },
      "id": "VAR-202505-0403",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09664"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09664"
          }
        ]
      },
      "last_update_date": "2025-06-06T23:07:16.080000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006276"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44900"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/faqiadegege/iotvuln/blob/main/tenda_rx3_getparentcontrolinfo_mac_overflow/detail.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-44900"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09664"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006276"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44900"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09664"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006276"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-44900"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09664"
          },
          {
            "date": "2025-06-05T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006276"
          },
          {
            "date": "2025-05-06T18:15:38.560000",
            "db": "NVD",
            "id": "CVE-2025-44900"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09664"
          },
          {
            "date": "2025-06-05T04:10:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006276"
          },
          {
            "date": "2025-06-04T17:25:54.930000",
            "db": "NVD",
            "id": "CVE-2025-44900"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0RX3\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006276"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202504-0693

    Vulnerability from variot - Updated: 2025-04-20 23:23

    A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of RX3 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to cause a denial of service or execute arbitrary code

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202504-0693",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "16.03.13.11_multi"
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "rx3  firmware  16.03.13.11 multi"
          },
          {
            "model": "rx3",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "16.03.13.11"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07517"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003359"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3259"
          }
        ]
      },
      "cve": "CVE-2025-3259",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-3259",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-003359",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-07517",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-3259",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-003359",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-3259",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-3259",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-003359",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-07517",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07517"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003359"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3259"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3259"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of RX3 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to cause a denial of service or execute arbitrary code",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-3259"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003359"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-07517"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-3259",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "303329",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003359",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-07517",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07517"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003359"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3259"
          }
        ]
      },
      "id": "VAR-202504-0693",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07517"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07517"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:23:16.340000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003359"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3259"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://sixth-action-50e.notion.site/tenda-rx3-buffer-overflow-1c9f6468377380a2977cd6c3a81f453c?pvs=4"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.303329"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.549199"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.8,
            "url": "https://sixth-action-50e.notion.site/tenda-rx3-buffer-overflow-1c9f6468377380a2977cd6c3a81f453c"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-3259"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.303329"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07517"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003359"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3259"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07517"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003359"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3259"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-11T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-07517"
          },
          {
            "date": "2025-04-14T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003359"
          },
          {
            "date": "2025-04-04T18:15:49.137000",
            "db": "NVD",
            "id": "CVE-2025-3259"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-07517"
          },
          {
            "date": "2025-04-14T05:50:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-003359"
          },
          {
            "date": "2025-04-07T18:19:20.090000",
            "db": "NVD",
            "id": "CVE-2025-3259"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0RX3\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-003359"
          }
        ],
        "trust": 0.8
      }
    }