Search criteria

4 vulnerabilities found for pro-face_gp-pro_ex by schneider-electric

CVE-2023-3953 (GCVE-0-2023-3953)

Vulnerability from nvd – Published: 2023-08-09 14:02 – Updated: 2024-10-09 18:10
VLAI?
Summary
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause memory corruption when an authenticated user opens a tampered log file from GP-Pro EX.
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:08:50.790Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-220-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-220-01.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-3953",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-09T17:55:24.434489Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-09T18:10:11.842Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GP-Pro EX WinGP for iPC",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "v4.09.450 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GP-Pro EX WinGP for PC/AT",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "v4.09.450 and prior"
            }
          ]
        }
      ],
      "datePublic": "2023-08-08T13:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nA CWE-119: Improper Restriction of Operations within the Bounds of a Memory\nBuffer vulnerability exists that could cause memory corruption when an authenticated user\nopens a tampered log file from GP-Pro EX."
            }
          ],
          "value": "\nA CWE-119: Improper Restriction of Operations within the Bounds of a Memory\nBuffer vulnerability exists that could cause memory corruption when an authenticated user\nopens a tampered log file from GP-Pro EX."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-09T14:02:44.472Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-220-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-220-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2023-3953",
    "datePublished": "2023-08-09T14:02:44.472Z",
    "dateReserved": "2023-07-26T08:14:55.340Z",
    "dateUpdated": "2024-10-09T18:10:11.842Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7832 (GCVE-0-2018-7832)

Vulnerability from nvd – Published: 2018-12-24 16:00 – Updated: 2024-08-05 06:37
VLAI?
Summary
An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched.
Severity ?
No CVSS data available.
CWE
  • Improper Input Validation
Assigner
Impacted products
Vendor Product Version
Schneider Electric SE Pro-Face GP-Pro EX v4.08 and previous versions Affected: Pro-Face GP-Pro EX v4.08 and previous versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.499Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/"
          },
          {
            "name": "106441",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106441"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Pro-Face GP-Pro EX v4.08 and previous versions",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "Pro-Face GP-Pro EX v4.08 and previous versions"
            }
          ]
        }
      ],
      "datePublic": "2018-12-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Input Validation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-28T17:29:34",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/"
        },
        {
          "name": "106441",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106441"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2018-7832",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Pro-Face GP-Pro EX v4.08 and previous versions",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Pro-Face GP-Pro EX v4.08 and previous versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/"
            },
            {
              "name": "106441",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106441"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7832",
    "datePublished": "2018-12-24T16:00:00",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-08-05T06:37:59.499Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-3953 (GCVE-0-2023-3953)

Vulnerability from cvelistv5 – Published: 2023-08-09 14:02 – Updated: 2024-10-09 18:10
VLAI?
Summary
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause memory corruption when an authenticated user opens a tampered log file from GP-Pro EX.
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:08:50.790Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-220-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-220-01.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-3953",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-09T17:55:24.434489Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-09T18:10:11.842Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GP-Pro EX WinGP for iPC",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "v4.09.450 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GP-Pro EX WinGP for PC/AT",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "v4.09.450 and prior"
            }
          ]
        }
      ],
      "datePublic": "2023-08-08T13:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nA CWE-119: Improper Restriction of Operations within the Bounds of a Memory\nBuffer vulnerability exists that could cause memory corruption when an authenticated user\nopens a tampered log file from GP-Pro EX."
            }
          ],
          "value": "\nA CWE-119: Improper Restriction of Operations within the Bounds of a Memory\nBuffer vulnerability exists that could cause memory corruption when an authenticated user\nopens a tampered log file from GP-Pro EX."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-09T14:02:44.472Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-220-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-220-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2023-3953",
    "datePublished": "2023-08-09T14:02:44.472Z",
    "dateReserved": "2023-07-26T08:14:55.340Z",
    "dateUpdated": "2024-10-09T18:10:11.842Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7832 (GCVE-0-2018-7832)

Vulnerability from cvelistv5 – Published: 2018-12-24 16:00 – Updated: 2024-08-05 06:37
VLAI?
Summary
An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched.
Severity ?
No CVSS data available.
CWE
  • Improper Input Validation
Assigner
Impacted products
Vendor Product Version
Schneider Electric SE Pro-Face GP-Pro EX v4.08 and previous versions Affected: Pro-Face GP-Pro EX v4.08 and previous versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.499Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/"
          },
          {
            "name": "106441",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106441"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Pro-Face GP-Pro EX v4.08 and previous versions",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "Pro-Face GP-Pro EX v4.08 and previous versions"
            }
          ]
        }
      ],
      "datePublic": "2018-12-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Input Validation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-28T17:29:34",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/"
        },
        {
          "name": "106441",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106441"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2018-7832",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Pro-Face GP-Pro EX v4.08 and previous versions",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Pro-Face GP-Pro EX v4.08 and previous versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-02/"
            },
            {
              "name": "106441",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106441"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-003-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7832",
    "datePublished": "2018-12-24T16:00:00",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-08-05T06:37:59.499Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}