Search criteria
16 vulnerabilities found for powerprotect_data_domain by dell
CVE-2025-29987 (GCVE-0-2025-29987)
Vulnerability from nvd – Published: 2025-04-03 15:18 – Updated: 2025-04-05 03:55
VLAI?
Summary
Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) versions prior to 8.3.0.15 contain an Insufficient Granularity of Access Control vulnerability. An authenticated user from a trusted remote client could exploit this vulnerability to execute arbitrary commands with root privileges.
Severity ?
8.8 (High)
CWE
- CWE-1220 - Insufficient Granularity of Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dell | DD OS 8.3 |
Affected:
7.7.1.0 , ≤ 8.3.0.10
(semver)
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-29987",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-04T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-05T03:55:35.210Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DD OS 8.3",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "8.3.0.10",
"status": "affected",
"version": "7.7.1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DD OS 7.13",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "7.13.1.20",
"status": "affected",
"version": "7.13.1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DD OS 7.10",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "7.10.1.50",
"status": "affected",
"version": "7.10.1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerProtect DP Series Appliance (IDPA)",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.7.8",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2025-04-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) versions prior to 8.3.0.15 contain an Insufficient Granularity of Access Control vulnerability. An authenticated user from a trusted remote client could exploit this vulnerability to execute arbitrary commands with root privileges.\u003cbr\u003e"
}
],
"value": "Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) versions prior to 8.3.0.15 contain an Insufficient Granularity of Access Control vulnerability. An authenticated user from a trusted remote client could exploit this vulnerability to execute arbitrary commands with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1220",
"description": "CWE-1220: Insufficient Granularity of Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-03T15:18:06.144Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000300899/dsa-2025-139-dell-technologies-powerprotect-data-domain-security-update-for-a-security-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2025-29987",
"datePublished": "2025-04-03T15:18:06.144Z",
"dateReserved": "2025-03-13T05:03:56.322Z",
"dateUpdated": "2025-04-05T03:55:35.210Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48667 (GCVE-0-2023-48667)
Vulnerability from nvd – Published: 2023-12-14 15:40 – Updated: 2024-08-02 21:37
VLAI?
Summary
Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application's underlying OS to bypass security restriction. Exploitation may lead to a system take over by an attacker.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:54.550Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110"
}
]
}
],
"datePublic": "2023-12-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS to bypass security restriction. Exploitation may lead to a system take over by an attacker. \u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS to bypass security restriction. Exploitation may lead to a system take over by an attacker. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:40:07.760Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48667",
"datePublished": "2023-12-14T15:40:07.760Z",
"dateReserved": "2023-11-17T06:14:57.042Z",
"dateUpdated": "2024-08-02T21:37:54.550Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44286 (GCVE-0-2023-44286)
Vulnerability from nvd – Published: 2023-12-14 15:35 – Updated: 2024-08-02 19:59
VLAI?
Summary
Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a DOM-based Cross-Site Scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the injection of malicious HTML or JavaScript code to a victim user's DOM environment in the browser. . Exploitation may lead to information disclosure, session theft, or client-side request forgery.
Severity ?
8.8 (High)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110ersions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
Credits
Dell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanisław Koza from STM Cyber for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:52.026Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD ",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110ersions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanis\u0142aw Koza from STM Cyber for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a DOM-based Cross-Site Scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the injection of malicious HTML or JavaScript code to a victim user\u0027s DOM environment in the browser. . Exploitation may lead to information disclosure, session theft, or client-side request forgery. \u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a DOM-based Cross-Site Scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the injection of malicious HTML or JavaScript code to a victim user\u0027s DOM environment in the browser. . Exploitation may lead to information disclosure, session theft, or client-side request forgery. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:35:32.521Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44286",
"datePublished": "2023-12-14T15:35:32.521Z",
"dateReserved": "2023-09-28T09:25:45.714Z",
"dateUpdated": "2024-08-02T19:59:52.026Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44285 (GCVE-0-2023-44285)
Vulnerability from nvd – Published: 2023-12-14 15:31 – Updated: 2024-08-02 19:59
VLAI?
Summary
Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege.
Severity ?
7.8 (High)
CWE
- CWE-1220 - Insufficient Granularity of Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
Credits
Dell Technologies would like to thank Jens Krüger from SAP for reporting this issue.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:51.974Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank Jens Kr\u00fcger from SAP for reporting this issue. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege.\u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1220",
"description": "CWE-1220: Insufficient Granularity of Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:31:14.009Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44285",
"datePublished": "2023-12-14T15:31:14.009Z",
"dateReserved": "2023-09-28T09:25:45.714Z",
"dateUpdated": "2024-08-02T19:59:51.974Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44284 (GCVE-0-2023-44284)
Vulnerability from nvd – Published: 2023-12-14 15:26 – Updated: 2024-11-21 16:20
VLAI?
Summary
Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an SQL Injection vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application's backend database causing unauthorized read access to application data.
Severity ?
4.3 (Medium)
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
Credits
Dell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanisław Koza from STM Cyber for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:51.944Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-44284",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-21T16:19:54.936040Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-21T16:20:17.129Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanis\u0142aw Koza from STM Cyber for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an SQL Injection vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application\u0027s backend database causing unauthorized read access to application data. \u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an SQL Injection vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application\u0027s backend database causing unauthorized read access to application data. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:26:43.251Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44284",
"datePublished": "2023-12-14T15:26:43.251Z",
"dateReserved": "2023-09-28T09:25:45.714Z",
"dateUpdated": "2024-11-21T16:20:17.129Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44279 (GCVE-0-2023-44279)
Vulnerability from nvd – Published: 2023-12-14 15:22 – Updated: 2024-10-01 14:44
VLAI?
Summary
Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A local high privileged attacker could potentially exploit this vulnerability, to bypass security restrictions. Exploitation may lead to a system take over by an attacker
Severity ?
6.7 (Medium)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
Credits
Dell Technologies would like to thank Rushank Shetty and Ryan Kane (Security Researchers at Northwestern Mutual) for reporting this issue.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:51.987Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "powerprotect_data_domain",
"vendor": "dell",
"versions": [
{
"lessThan": "7.13.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:dell:powerprotect_data_domain:-:*:*:*:lts:*:*:*"
],
"defaultStatus": "unknown",
"product": "powerprotect_data_domain",
"vendor": "dell",
"versions": [
{
"status": "affected",
"version": "7.7.5.25"
},
{
"status": "affected",
"version": "7.10.1.15"
},
{
"status": "affected",
"version": "6.2.1.110"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-44279",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-26T17:07:53.377116Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-01T14:44:19.118Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank Rushank Shetty and Ryan Kane (Security Researchers at Northwestern Mutual) for reporting this issue. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A local high privileged attacker could potentially exploit this vulnerability, to bypass security restrictions. Exploitation may lead to a system take over by an attacker\u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A local high privileged attacker could potentially exploit this vulnerability, to bypass security restrictions. Exploitation may lead to a system take over by an attacker\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:22:27.116Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44279",
"datePublished": "2023-12-14T15:22:27.116Z",
"dateReserved": "2023-09-28T09:25:45.713Z",
"dateUpdated": "2024-10-01T14:44:19.118Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44278 (GCVE-0-2023-44278)
Vulnerability from nvd – Published: 2023-12-14 15:17 – Updated: 2024-08-02 19:59
VLAI?
Summary
Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a path traversal vulnerability. A local high privileged attacker could potentially exploit this vulnerability, to gain unauthorized read and write access to the OS files stored on the server filesystem, with the privileges of the running application.
Severity ?
6.7 (Medium)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:51.937Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 "
}
]
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a path traversal vulnerability. A local high privileged attacker could potentially exploit this vulnerability, to gain unauthorized read and write access to the OS files stored on the server filesystem, with the privileges of the running application. \u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a path traversal vulnerability. A local high privileged attacker could potentially exploit this vulnerability, to gain unauthorized read and write access to the OS files stored on the server filesystem, with the privileges of the running application. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:17:01.213Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44278",
"datePublished": "2023-12-14T15:17:01.213Z",
"dateReserved": "2023-09-28T09:25:45.713Z",
"dateUpdated": "2024-08-02T19:59:51.937Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44277 (GCVE-0-2023-44277)
Vulnerability from nvd – Published: 2023-12-14 15:05 – Updated: 2024-08-02 19:59
VLAI?
Summary
Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in the CLI. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application's underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.
Severity ?
7.8 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
Credits
ell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanisław Koza from STM Cyber for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:52.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 "
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanis\u0142aw Koza from STM Cyber for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in the CLI. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker. \u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in the CLI. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:05:01.367Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44277",
"datePublished": "2023-12-14T15:05:01.367Z",
"dateReserved": "2023-09-28T09:25:45.713Z",
"dateUpdated": "2024-08-02T19:59:52.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-29987 (GCVE-0-2025-29987)
Vulnerability from cvelistv5 – Published: 2025-04-03 15:18 – Updated: 2025-04-05 03:55
VLAI?
Summary
Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) versions prior to 8.3.0.15 contain an Insufficient Granularity of Access Control vulnerability. An authenticated user from a trusted remote client could exploit this vulnerability to execute arbitrary commands with root privileges.
Severity ?
8.8 (High)
CWE
- CWE-1220 - Insufficient Granularity of Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dell | DD OS 8.3 |
Affected:
7.7.1.0 , ≤ 8.3.0.10
(semver)
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-29987",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-04T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-05T03:55:35.210Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DD OS 8.3",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "8.3.0.10",
"status": "affected",
"version": "7.7.1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DD OS 7.13",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "7.13.1.20",
"status": "affected",
"version": "7.13.1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DD OS 7.10",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "7.10.1.50",
"status": "affected",
"version": "7.10.1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerProtect DP Series Appliance (IDPA)",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.7.8",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2025-04-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) versions prior to 8.3.0.15 contain an Insufficient Granularity of Access Control vulnerability. An authenticated user from a trusted remote client could exploit this vulnerability to execute arbitrary commands with root privileges.\u003cbr\u003e"
}
],
"value": "Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) versions prior to 8.3.0.15 contain an Insufficient Granularity of Access Control vulnerability. An authenticated user from a trusted remote client could exploit this vulnerability to execute arbitrary commands with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1220",
"description": "CWE-1220: Insufficient Granularity of Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-03T15:18:06.144Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000300899/dsa-2025-139-dell-technologies-powerprotect-data-domain-security-update-for-a-security-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2025-29987",
"datePublished": "2025-04-03T15:18:06.144Z",
"dateReserved": "2025-03-13T05:03:56.322Z",
"dateUpdated": "2025-04-05T03:55:35.210Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48667 (GCVE-0-2023-48667)
Vulnerability from cvelistv5 – Published: 2023-12-14 15:40 – Updated: 2024-08-02 21:37
VLAI?
Summary
Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application's underlying OS to bypass security restriction. Exploitation may lead to a system take over by an attacker.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:37:54.550Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110"
}
]
}
],
"datePublic": "2023-12-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS to bypass security restriction. Exploitation may lead to a system take over by an attacker. \u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A remote high privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS to bypass security restriction. Exploitation may lead to a system take over by an attacker. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:40:07.760Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-48667",
"datePublished": "2023-12-14T15:40:07.760Z",
"dateReserved": "2023-11-17T06:14:57.042Z",
"dateUpdated": "2024-08-02T21:37:54.550Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44286 (GCVE-0-2023-44286)
Vulnerability from cvelistv5 – Published: 2023-12-14 15:35 – Updated: 2024-08-02 19:59
VLAI?
Summary
Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a DOM-based Cross-Site Scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the injection of malicious HTML or JavaScript code to a victim user's DOM environment in the browser. . Exploitation may lead to information disclosure, session theft, or client-side request forgery.
Severity ?
8.8 (High)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110ersions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
Credits
Dell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanisław Koza from STM Cyber for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:52.026Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD ",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110ersions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanis\u0142aw Koza from STM Cyber for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a DOM-based Cross-Site Scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the injection of malicious HTML or JavaScript code to a victim user\u0027s DOM environment in the browser. . Exploitation may lead to information disclosure, session theft, or client-side request forgery. \u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a DOM-based Cross-Site Scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the injection of malicious HTML or JavaScript code to a victim user\u0027s DOM environment in the browser. . Exploitation may lead to information disclosure, session theft, or client-side request forgery. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:35:32.521Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44286",
"datePublished": "2023-12-14T15:35:32.521Z",
"dateReserved": "2023-09-28T09:25:45.714Z",
"dateUpdated": "2024-08-02T19:59:52.026Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44285 (GCVE-0-2023-44285)
Vulnerability from cvelistv5 – Published: 2023-12-14 15:31 – Updated: 2024-08-02 19:59
VLAI?
Summary
Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege.
Severity ?
7.8 (High)
CWE
- CWE-1220 - Insufficient Granularity of Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
Credits
Dell Technologies would like to thank Jens Krüger from SAP for reporting this issue.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:51.974Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank Jens Kr\u00fcger from SAP for reporting this issue. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege.\u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an improper access control vulnerability. A local malicious user with low privileges could potentially exploit this vulnerability leading to escalation of privilege.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1220",
"description": "CWE-1220: Insufficient Granularity of Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:31:14.009Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44285",
"datePublished": "2023-12-14T15:31:14.009Z",
"dateReserved": "2023-09-28T09:25:45.714Z",
"dateUpdated": "2024-08-02T19:59:51.974Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44284 (GCVE-0-2023-44284)
Vulnerability from cvelistv5 – Published: 2023-12-14 15:26 – Updated: 2024-11-21 16:20
VLAI?
Summary
Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an SQL Injection vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application's backend database causing unauthorized read access to application data.
Severity ?
4.3 (Medium)
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
Credits
Dell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanisław Koza from STM Cyber for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:51.944Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-44284",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-21T16:19:54.936040Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-21T16:20:17.129Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanis\u0142aw Koza from STM Cyber for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an SQL Injection vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application\u0027s backend database causing unauthorized read access to application data. \u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an SQL Injection vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of certain SQL commands on the application\u0027s backend database causing unauthorized read access to application data. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:26:43.251Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44284",
"datePublished": "2023-12-14T15:26:43.251Z",
"dateReserved": "2023-09-28T09:25:45.714Z",
"dateUpdated": "2024-11-21T16:20:17.129Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44279 (GCVE-0-2023-44279)
Vulnerability from cvelistv5 – Published: 2023-12-14 15:22 – Updated: 2024-10-01 14:44
VLAI?
Summary
Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A local high privileged attacker could potentially exploit this vulnerability, to bypass security restrictions. Exploitation may lead to a system take over by an attacker
Severity ?
6.7 (Medium)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
Credits
Dell Technologies would like to thank Rushank Shetty and Ryan Kane (Security Researchers at Northwestern Mutual) for reporting this issue.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:51.987Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "powerprotect_data_domain",
"vendor": "dell",
"versions": [
{
"lessThan": "7.13.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:dell:powerprotect_data_domain:-:*:*:*:lts:*:*:*"
],
"defaultStatus": "unknown",
"product": "powerprotect_data_domain",
"vendor": "dell",
"versions": [
{
"status": "affected",
"version": "7.7.5.25"
},
{
"status": "affected",
"version": "7.10.1.15"
},
{
"status": "affected",
"version": "6.2.1.110"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-44279",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-26T17:07:53.377116Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-01T14:44:19.118Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Dell Technologies would like to thank Rushank Shetty and Ryan Kane (Security Researchers at Northwestern Mutual) for reporting this issue. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A local high privileged attacker could potentially exploit this vulnerability, to bypass security restrictions. Exploitation may lead to a system take over by an attacker\u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in administrator CLI. A local high privileged attacker could potentially exploit this vulnerability, to bypass security restrictions. Exploitation may lead to a system take over by an attacker\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:22:27.116Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44279",
"datePublished": "2023-12-14T15:22:27.116Z",
"dateReserved": "2023-09-28T09:25:45.713Z",
"dateUpdated": "2024-10-01T14:44:19.118Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44278 (GCVE-0-2023-44278)
Vulnerability from cvelistv5 – Published: 2023-12-14 15:17 – Updated: 2024-08-02 19:59
VLAI?
Summary
Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a path traversal vulnerability. A local high privileged attacker could potentially exploit this vulnerability, to gain unauthorized read and write access to the OS files stored on the server filesystem, with the privileges of the running application.
Severity ?
6.7 (Medium)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:51.937Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 "
}
]
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a path traversal vulnerability. A local high privileged attacker could potentially exploit this vulnerability, to gain unauthorized read and write access to the OS files stored on the server filesystem, with the privileges of the running application. \u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a path traversal vulnerability. A local high privileged attacker could potentially exploit this vulnerability, to gain unauthorized read and write access to the OS files stored on the server filesystem, with the privileges of the running application. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:17:01.213Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44278",
"datePublished": "2023-12-14T15:17:01.213Z",
"dateReserved": "2023-09-28T09:25:45.713Z",
"dateUpdated": "2024-08-02T19:59:51.937Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44277 (GCVE-0-2023-44277)
Vulnerability from cvelistv5 – Published: 2023-12-14 15:05 – Updated: 2024-08-02 19:59
VLAI?
Summary
Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in the CLI. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application's underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.
Severity ?
7.8 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110
|
Credits
ell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanisław Koza from STM Cyber for reporting these issues.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:52.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 "
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ell Technologies would like to thank Jakub Brzozowski (redfr0g), Franciszek Kalinowski, and Stanis\u0142aw Koza from STM Cyber for reporting these issues. "
}
],
"datePublic": "2023-12-13T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in the CLI. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker. \u003c/span\u003e\n\n"
}
],
"value": "\nDell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in the CLI. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application\u0027s underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker. \n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T15:05:01.367Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000220264/dsa-2023-412-dell-technologies-powerprotect-security-update-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44277",
"datePublished": "2023-12-14T15:05:01.367Z",
"dateReserved": "2023-09-28T09:25:45.713Z",
"dateUpdated": "2024-08-02T19:59:52.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}