Search criteria

8 vulnerabilities found for pi_studio_hmi by we-con

CVE-2018-14814 (GCVE-0-2018-14814)

Vulnerability from nvd – Published: 2019-03-27 19:50 – Updated: 2024-08-05 09:38
VLAI?
Summary
WECON Technology PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior lacks proper validation of user-supplied data, which may result in a read past the end of an allocated object.
Severity ?
No CVSS data available.
CWE
  • CWE-125 - Out-of-bounds read CWE-125
Assigner
References
Impacted products
Vendor Product Version
WECON WECON Technology PI Studio HMI Affected: PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:14.118Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WECON Technology PI Studio HMI",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "WECON Technology PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior lacks proper validation of user-supplied data, which may result in a read past the end of an allocated object."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "Out-of-bounds read CWE-125",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-27T19:50:08",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2018-14814",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "WECON Technology PI Studio HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "WECON"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WECON Technology PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior lacks proper validation of user-supplied data, which may result in a read past the end of an allocated object."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Out-of-bounds read CWE-125"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14814",
    "datePublished": "2019-03-27T19:50:08",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-08-05T09:38:14.118Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-17889 (GCVE-0-2018-17889)

Vulnerability from nvd – Published: 2018-10-08 13:00 – Updated: 2024-09-17 00:15
VLAI?
Summary
In WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior when parsing project files, the XMLParser that ships with Wecon PIStudio is vulnerable to a XML external entity injection attack, which may allow sensitive information disclosure.
Severity ?
No CVSS data available.
CWE
  • CWE-611 - INFORMATION EXPOSURE THROUGH XML EXTERNAL ENTITY REFERENCE CWE-611
Assigner
References
Impacted products
Vendor Product Version
WECON PI Studio HMI Affected: 4.1.9 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:01:14.662Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PI Studio HMI",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.9 and prior"
            }
          ]
        },
        {
          "product": "PI Studio",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.2.34 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior when parsing project files, the XMLParser that ships with Wecon PIStudio is vulnerable to a XML external entity injection attack, which may allow sensitive information disclosure."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "INFORMATION EXPOSURE THROUGH XML EXTERNAL ENTITY REFERENCE CWE-611",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-08T12:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-04T00:00:00",
          "ID": "CVE-2018-17889",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PI Studio HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.9 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PI Studio",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.2.34 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "WECON"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior when parsing project files, the XMLParser that ships with Wecon PIStudio is vulnerable to a XML external entity injection attack, which may allow sensitive information disclosure."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "INFORMATION EXPOSURE THROUGH XML EXTERNAL ENTITY REFERENCE CWE-611"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-17889",
    "datePublished": "2018-10-08T13:00:00Z",
    "dateReserved": "2018-10-02T00:00:00",
    "dateUpdated": "2024-09-17T00:15:34.493Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-14818 (GCVE-0-2018-14818)

Vulnerability from nvd – Published: 2018-10-08 13:00 – Updated: 2024-09-17 02:37
VLAI?
Summary
WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior have a stack-based buffer overflow vulnerability which may allow remote code execution.
Severity ?
No CVSS data available.
CWE
  • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
Impacted products
Vendor Product Version
WECON PI Studio HMI Affected: 4.1.9 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:14.008Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PI Studio HMI",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.9 and prior"
            }
          ]
        },
        {
          "product": "PI Studio",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.2.34 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior have a stack-based buffer overflow vulnerability which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-08T12:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-04T00:00:00",
          "ID": "CVE-2018-14818",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PI Studio HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.9 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PI Studio",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.2.34 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "WECON"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior have a stack-based buffer overflow vulnerability which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14818",
    "datePublished": "2018-10-08T13:00:00Z",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-09-17T02:37:32.231Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-14810 (GCVE-0-2018-14810)

Vulnerability from nvd – Published: 2018-10-08 13:00 – Updated: 2024-09-16 18:18
VLAI?
Summary
WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior parse files and pass invalidated user data to an unsafe method call, which may allow code to be executed in the context of an administrator.
Severity ?
No CVSS data available.
CWE
  • CWE-787 - OUT-OF-BOUNDS WRITE CWE-787
Assigner
References
Impacted products
Vendor Product Version
WECON PI Studio HMI Affected: 4.1.9 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:14.059Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PI Studio HMI",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.9 and prior"
            }
          ]
        },
        {
          "product": "PI Studio",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.2.34 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior parse files and pass invalidated user data to an unsafe method call, which may allow code to be executed in the context of an administrator."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "OUT-OF-BOUNDS WRITE CWE-787",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-08T12:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-04T00:00:00",
          "ID": "CVE-2018-14810",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PI Studio HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.9 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PI Studio",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.2.34 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "WECON"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior parse files and pass invalidated user data to an unsafe method call, which may allow code to be executed in the context of an administrator."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OUT-OF-BOUNDS WRITE CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14810",
    "datePublished": "2018-10-08T13:00:00Z",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-09-16T18:18:08.589Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-14814 (GCVE-0-2018-14814)

Vulnerability from cvelistv5 – Published: 2019-03-27 19:50 – Updated: 2024-08-05 09:38
VLAI?
Summary
WECON Technology PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior lacks proper validation of user-supplied data, which may result in a read past the end of an allocated object.
Severity ?
No CVSS data available.
CWE
  • CWE-125 - Out-of-bounds read CWE-125
Assigner
References
Impacted products
Vendor Product Version
WECON WECON Technology PI Studio HMI Affected: PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:14.118Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WECON Technology PI Studio HMI",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "WECON Technology PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior lacks proper validation of user-supplied data, which may result in a read past the end of an allocated object."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "Out-of-bounds read CWE-125",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-27T19:50:08",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2018-14814",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "WECON Technology PI Studio HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "WECON"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WECON Technology PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior lacks proper validation of user-supplied data, which may result in a read past the end of an allocated object."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Out-of-bounds read CWE-125"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14814",
    "datePublished": "2019-03-27T19:50:08",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-08-05T09:38:14.118Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-14818 (GCVE-0-2018-14818)

Vulnerability from cvelistv5 – Published: 2018-10-08 13:00 – Updated: 2024-09-17 02:37
VLAI?
Summary
WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior have a stack-based buffer overflow vulnerability which may allow remote code execution.
Severity ?
No CVSS data available.
CWE
  • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
Impacted products
Vendor Product Version
WECON PI Studio HMI Affected: 4.1.9 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:14.008Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PI Studio HMI",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.9 and prior"
            }
          ]
        },
        {
          "product": "PI Studio",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.2.34 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior have a stack-based buffer overflow vulnerability which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-08T12:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-04T00:00:00",
          "ID": "CVE-2018-14818",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PI Studio HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.9 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PI Studio",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.2.34 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "WECON"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior have a stack-based buffer overflow vulnerability which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14818",
    "datePublished": "2018-10-08T13:00:00Z",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-09-17T02:37:32.231Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-14810 (GCVE-0-2018-14810)

Vulnerability from cvelistv5 – Published: 2018-10-08 13:00 – Updated: 2024-09-16 18:18
VLAI?
Summary
WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior parse files and pass invalidated user data to an unsafe method call, which may allow code to be executed in the context of an administrator.
Severity ?
No CVSS data available.
CWE
  • CWE-787 - OUT-OF-BOUNDS WRITE CWE-787
Assigner
References
Impacted products
Vendor Product Version
WECON PI Studio HMI Affected: 4.1.9 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:38:14.059Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PI Studio HMI",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.9 and prior"
            }
          ]
        },
        {
          "product": "PI Studio",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.2.34 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior parse files and pass invalidated user data to an unsafe method call, which may allow code to be executed in the context of an administrator."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "OUT-OF-BOUNDS WRITE CWE-787",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-08T12:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-04T00:00:00",
          "ID": "CVE-2018-14810",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PI Studio HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.9 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PI Studio",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.2.34 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "WECON"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior parse files and pass invalidated user data to an unsafe method call, which may allow code to be executed in the context of an administrator."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OUT-OF-BOUNDS WRITE CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-14810",
    "datePublished": "2018-10-08T13:00:00Z",
    "dateReserved": "2018-08-01T00:00:00",
    "dateUpdated": "2024-09-16T18:18:08.589Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-17889 (GCVE-0-2018-17889)

Vulnerability from cvelistv5 – Published: 2018-10-08 13:00 – Updated: 2024-09-17 00:15
VLAI?
Summary
In WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior when parsing project files, the XMLParser that ships with Wecon PIStudio is vulnerable to a XML external entity injection attack, which may allow sensitive information disclosure.
Severity ?
No CVSS data available.
CWE
  • CWE-611 - INFORMATION EXPOSURE THROUGH XML EXTERNAL ENTITY REFERENCE CWE-611
Assigner
References
Impacted products
Vendor Product Version
WECON PI Studio HMI Affected: 4.1.9 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:01:14.662Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PI Studio HMI",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.9 and prior"
            }
          ]
        },
        {
          "product": "PI Studio",
          "vendor": "WECON",
          "versions": [
            {
              "status": "affected",
              "version": "4.2.34 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior when parsing project files, the XMLParser that ships with Wecon PIStudio is vulnerable to a XML external entity injection attack, which may allow sensitive information disclosure."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "INFORMATION EXPOSURE THROUGH XML EXTERNAL ENTITY REFERENCE CWE-611",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-08T12:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-04T00:00:00",
          "ID": "CVE-2018-17889",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PI Studio HMI",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.9 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PI Studio",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.2.34 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "WECON"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior when parsing project files, the XMLParser that ships with Wecon PIStudio is vulnerable to a XML external entity injection attack, which may allow sensitive information disclosure."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "INFORMATION EXPOSURE THROUGH XML EXTERNAL ENTITY REFERENCE CWE-611"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-277-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-17889",
    "datePublished": "2018-10-08T13:00:00Z",
    "dateReserved": "2018-10-02T00:00:00",
    "dateUpdated": "2024-09-17T00:15:34.493Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}