Search criteria
46 vulnerabilities found for modicon_premium_firmware by schneider-electric
CVE-2019-6828 (GCVE-0-2019-6828)
Vulnerability from nvd – Published: 2019-09-17 19:59 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric SE | Modicon M580 |
Affected:
firmware version prior to V2.90
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.247Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V2.90"
}
]
},
{
"product": "Modicon M340",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V3.10"
}
]
},
{
"product": "Modicon Premium",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "Modicon Quantum",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:59:33",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6828",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V2.90"
}
]
}
},
{
"product_name": "Modicon M340",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V3.10"
}
]
}
},
{
"product_name": "Modicon Premium",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "Modicon Quantum",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6828",
"datePublished": "2019-09-17T19:59:33",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6809 (GCVE-0-2019-6809)
Vulnerability from nvd – Published: 2019-09-17 19:50 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller.
Severity ?
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric SE | Modicon M580 |
Affected:
firmware version prior to V2.90
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.229Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V2.90"
}
]
},
{
"product": "Modicon M340",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V3.10"
}
]
},
{
"product": "Modicon Premium",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "Modicon Quantum",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:50:29",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6809",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V2.90"
}
]
}
},
{
"product_name": "Modicon M340",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V3.10"
}
]
}
},
{
"product_name": "Modicon Premium",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "Modicon Quantum",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6809",
"datePublished": "2019-09-17T19:50:29",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.229Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6808 (GCVE-0-2019-6808)
Vulnerability from nvd – Published: 2019-05-22 20:05 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.192Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0771"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0771"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6808",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0771",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0771"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6808",
"datePublished": "2019-05-22T20:05:50",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.192Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6807 (GCVE-0-2019-6807)
Vulnerability from nvd – Published: 2019-05-22 20:05 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.152Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0770"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0770"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6807",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0770",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0770"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6807",
"datePublished": "2019-05-22T20:05:13",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.152Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6806 (GCVE-0-2019-6806)
Vulnerability from nvd – Published: 2019-05-22 20:04 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.311Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0769"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0769"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6806",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0769",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0769"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6806",
"datePublished": "2019-05-22T20:04:46",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.311Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7857 (GCVE-0-2018-7857)
Vulnerability from nvd – Published: 2019-05-22 20:04 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.621Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0768"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0768"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7857",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0768",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0768"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7857",
"datePublished": "2019-05-22T20:04:10",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.621Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7856 (GCVE-0-2018-7856)
Vulnerability from nvd – Published: 2019-05-22 20:03 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.599Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-11T18:06:08",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7856",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7856",
"datePublished": "2019-05-22T20:03:45",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.599Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7855 (GCVE-0-2018-7855)
Vulnerability from nvd – Published: 2019-05-22 20:03 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.652Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:05",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7855",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7855",
"datePublished": "2019-05-22T20:03:17",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7854 (GCVE-0-2018-7854)
Vulnerability from nvd – Published: 2019-05-22 20:02 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.623Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0765"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0765"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7854",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0765",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0765"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7854",
"datePublished": "2019-05-22T20:02:52",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.623Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7853 (GCVE-0-2018-7853)
Vulnerability from nvd – Published: 2019-05-22 20:02 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.636Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0764"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0764"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7853",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0764",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0764"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7853",
"datePublished": "2019-05-22T20:02:11",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.636Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7844 (GCVE-0-2018-7844)
Vulnerability from nvd – Published: 2019-05-22 20:06 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.563Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0739"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T16:06:06",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0739"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7844",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0739",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0739"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7844",
"datePublished": "2019-05-22T20:06:09",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.563Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6821 (GCVE-0-2019-6821)
Vulnerability from nvd – Published: 2019-05-22 19:42 – Updated: 2024-08-04 20:31
VLAI?
Summary
CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum.
Severity ?
No CVSS data available.
CWE
- CWE-330 - Use of Insufficiently Random Values
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon Controllers, Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum |
Affected:
Modicon Controllers, Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.471Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-136-01"
},
{
"name": "108366",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108366"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon Controllers, Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon Controllers, Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-330",
"description": "CWE-330: Use of Insufficiently Random Values",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-17T19:34:06",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-136-01"
},
{
"name": "108366",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108366"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-03/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6821",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon Controllers, Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum",
"version": {
"version_data": [
{
"version_value": "Modicon Controllers, Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-330: Use of Insufficiently Random Values"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-136-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-136-01"
},
{
"name": "108366",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108366"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-03/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-03/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6821",
"datePublished": "2019-05-22T19:42:06",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.471Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6819 (GCVE-0-2019-6819)
Vulnerability from nvd – Published: 2019-05-22 19:45 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium.
Severity ?
No CVSS data available.
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon Controllers, Modicon M340 - firmware versions prior to V3.01 Modicon M580 - firmware versions prior to V2.80 All firmware versions of Modicon Quantum and Modicon Premium |
Affected:
Modicon Controllers, Modicon M340 - firmware versions prior to V3.01 Modicon M580 - firmware versions prior to V2.80 All firmware versions of Modicon Quantum and Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.277Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-05/"
},
{
"name": "109004",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/109004"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon Controllers, Modicon M340 - firmware versions prior to V3.01 Modicon M580 - firmware versions prior to V2.80 All firmware versions of Modicon Quantum and Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon Controllers, Modicon M340 - firmware versions prior to V3.01 Modicon M580 - firmware versions prior to V2.80 All firmware versions of Modicon Quantum and Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-03T13:06:07",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-05/"
},
{
"name": "109004",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/109004"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6819",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon Controllers, Modicon M340 - firmware versions prior to V3.01 Modicon M580 - firmware versions prior to V2.80 All firmware versions of Modicon Quantum and Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon Controllers, Modicon M340 - firmware versions prior to V3.01 Modicon M580 - firmware versions prior to V2.80 All firmware versions of Modicon Quantum and Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-05/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-05/"
},
{
"name": "109004",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/109004"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6819",
"datePublished": "2019-05-22T19:45:08",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.277Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7852 (GCVE-0-2018-7852)
Vulnerability from nvd – Published: 2019-05-22 20:01 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.655Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0763"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T16:06:06",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0763"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7852",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0763",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0763"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7852",
"datePublished": "2019-05-22T20:01:12",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.655Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7851 (GCVE-0-2018-7851)
Vulnerability from nvd – Published: 2019-05-22 19:56 – Updated: 2024-08-05 06:37
VLAI?
Summary
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.
Severity ?
No CVSS data available.
CWE
- CWE-119 - Buffer errors
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 with firmware prior to V2.50 Modicon M340 with firmware prior to V3.01 BMxCRA312xx with firmware prior to V2.40 All firmware versions of Modicon Premium and 140CRA312xxx |
Affected:
Modicon M580 with firmware prior to V2.50 Modicon M340 with firmware prior to V3.01 BMxCRA312xx with firmware prior to V2.40 All firmware versions of Modicon Premium and 140CRA312xxx
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.635Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-10/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 with firmware prior to V2.50 Modicon M340 with firmware prior to V3.01 BMxCRA312xx with firmware prior to V2.40 All firmware versions of Modicon Premium and 140CRA312xxx",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 with firmware prior to V2.50 Modicon M340 with firmware prior to V3.01 BMxCRA312xx with firmware prior to V2.40 All firmware versions of Modicon Premium and 140CRA312xxx"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Buffer errors",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-22T19:56:24",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-10/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7851",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 with firmware prior to V2.50 Modicon M340 with firmware prior to V3.01 BMxCRA312xx with firmware prior to V2.40 All firmware versions of Modicon Premium and 140CRA312xxx",
"version": {
"version_data": [
{
"version_value": "Modicon M580 with firmware prior to V2.50 Modicon M340 with firmware prior to V3.01 BMxCRA312xx with firmware prior to V2.40 All firmware versions of Modicon Premium and 140CRA312xxx"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119: Buffer errors"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-10/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-10/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7851",
"datePublished": "2019-05-22T19:56:24",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.635Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7850 (GCVE-0-2018-7850)
Vulnerability from nvd – Published: 2019-05-22 20:00 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-807: Reliance on Untrusted Inputs in a Security Decision vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause invalid information displayed in Unity Pro software.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.544Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0743"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-807: Reliance on Untrusted Inputs in a Security Decision vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause invalid information displayed in Unity Pro software."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-11T16:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0743"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7850",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-807: Reliance on Untrusted Inputs in a Security Decision vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause invalid information displayed in Unity Pro software."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0743",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0743"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7850",
"datePublished": "2019-05-22T20:00:27",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.544Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7849 (GCVE-0-2018-7849)
Vulnerability from nvd – Published: 2019-05-22 19:58 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of Service due to improper data integrity check when sending files the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.761Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0737"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of Service due to improper data integrity check when sending files the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T16:06:06",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0737"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7849",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of Service due to improper data integrity check when sending files the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0737",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0737"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7849",
"datePublished": "2019-05-22T19:58:16",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.761Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7848 (GCVE-0-2018-7848)
Vulnerability from nvd – Published: 2019-05-22 19:59 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.566Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0740"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T16:06:06",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0740"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7848",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0740",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0740"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7848",
"datePublished": "2019-05-22T19:59:26",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.566Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7847 (GCVE-0-2018-7847)
Vulnerability from nvd – Published: 2019-05-22 20:00 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.510Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0742"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0743"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T16:06:06",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0742"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0743"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7847",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0742",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0742"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0743",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0743"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7847",
"datePublished": "2019-05-22T20:00:04",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.510Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7846 (GCVE-0-2018-7846)
Vulnerability from nvd – Published: 2019-05-22 19:57 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.620Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0735"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T16:06:06",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0735"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7846",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0735",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0735"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7846",
"datePublished": "2019-05-22T19:57:42",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.620Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7845 (GCVE-0-2018-7845)
Vulnerability from nvd – Published: 2019-05-22 20:00 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-125: Out-of-bounds Read vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of unexpected data from the controller when reading specific memory blocks in the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.558Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0745"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-125: Out-of-bounds Read vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of unexpected data from the controller when reading specific memory blocks in the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T16:06:05",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0745"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7845",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-125: Out-of-bounds Read vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of unexpected data from the controller when reading specific memory blocks in the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0745",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0745"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7845",
"datePublished": "2019-05-22T20:00:49",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.558Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7843 (GCVE-0-2018-7843)
Vulnerability from nvd – Published: 2019-05-22 19:58 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.598Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T16:06:06",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7843",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7843",
"datePublished": "2019-05-22T19:58:58",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.598Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7842 (GCVE-0-2018-7842)
Vulnerability from nvd – Published: 2019-05-22 19:59 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.544Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0741"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T16:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0741"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7842",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0741",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0741"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7842",
"datePublished": "2019-05-22T19:59:46",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.544Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6828 (GCVE-0-2019-6828)
Vulnerability from cvelistv5 – Published: 2019-09-17 19:59 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric SE | Modicon M580 |
Affected:
firmware version prior to V2.90
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.247Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V2.90"
}
]
},
{
"product": "Modicon M340",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V3.10"
}
]
},
{
"product": "Modicon Premium",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "Modicon Quantum",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:59:33",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6828",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V2.90"
}
]
}
},
{
"product_name": "Modicon M340",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V3.10"
}
]
}
},
{
"product_name": "Modicon Premium",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "Modicon Quantum",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6828",
"datePublished": "2019-09-17T19:59:33",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6809 (GCVE-0-2019-6809)
Vulnerability from cvelistv5 – Published: 2019-09-17 19:50 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller.
Severity ?
No CVSS data available.
CWE
- CWE-248 - Uncaught Exception
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric SE | Modicon M580 |
Affected:
firmware version prior to V2.90
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.229Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V2.90"
}
]
},
{
"product": "Modicon M340",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V3.10"
}
]
},
{
"product": "Modicon Premium",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "Modicon Quantum",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:50:29",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6809",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V2.90"
}
]
}
},
{
"product_name": "Modicon M340",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V3.10"
}
]
}
},
{
"product_name": "Modicon Premium",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "Modicon Quantum",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6809",
"datePublished": "2019-09-17T19:50:29",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.229Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7844 (GCVE-0-2018-7844)
Vulnerability from cvelistv5 – Published: 2019-05-22 20:06 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.563Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0739"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T16:06:06",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0739"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7844",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0739",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0739"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7844",
"datePublished": "2019-05-22T20:06:09",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.563Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6808 (GCVE-0-2019-6808)
Vulnerability from cvelistv5 – Published: 2019-05-22 20:05 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.192Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0771"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0771"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6808",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0771",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0771"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6808",
"datePublished": "2019-05-22T20:05:50",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.192Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6807 (GCVE-0-2019-6807)
Vulnerability from cvelistv5 – Published: 2019-05-22 20:05 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.152Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0770"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0770"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6807",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0770",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0770"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6807",
"datePublished": "2019-05-22T20:05:13",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.152Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6806 (GCVE-0-2019-6806)
Vulnerability from cvelistv5 – Published: 2019-05-22 20:04 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.311Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0769"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0769"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6806",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0769",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0769"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6806",
"datePublished": "2019-05-22T20:04:46",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.311Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7857 (GCVE-0-2018-7857)
Vulnerability from cvelistv5 – Published: 2019-05-22 20:04 – Updated: 2024-08-05 06:37
VLAI?
Summary
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus.
Severity ?
No CVSS data available.
CWE
- Multiple Vulnerabilities
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.621Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0768"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:04",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0768"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7857",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0768",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0768"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7857",
"datePublished": "2019-05-22T20:04:10",
"dateReserved": "2018-03-08T00:00:00",
"dateUpdated": "2024-08-05T06:37:59.621Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}