Search

Find a vulnerability

Search criteria

    24 vulnerabilities found for modicon_m580_bmep583040_firmware by schneider-electric

    CVE-2023-6408 (GCVE-0-2023-6408)

    Vulnerability from nvd – Published: 2024-02-14 16:52 – Updated: 2024-08-02 08:28
    VLAI
    Summary
    CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric Modicon M340 CPU (part numbers BMXP34*) Affected: Versions prior to sv3.60
    Create a notification for this product.
    Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety) Affected: Versions prior to sv4.20
    Create a notification for this product.
    Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) Affected: All Versions
    Create a notification for this product.
    Schneider Electric EcoStruxure Control Expert Affected: Versions prior to v16.0
    Create a notification for this product.
    Schneider Electric EcoStruxure Process Expert Affected: Versions prior to v2023
    Create a notification for this product.
    schneider-electric modicon_m580_bmep585040_firmware Affected: 0 , < 4.20 (custom)
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    schneider-electric modicon_m340_bmxp342030h_firmware Affected: 0 , < 3.60 (custom)
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2010_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302cl_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2030_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030h_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    schneider-electric modicon_m580_bmeh586040s_firmware Affected: 0 , < * (custom)
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "modicon_m580_bmep585040_firmware",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThan": "4.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2010_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302cl_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2030_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030h_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "modicon_m340_bmxp342030h_firmware",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThan": "3.60",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "modicon_m580_bmeh586040s_firmware",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-6408",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-17T19:15:41.696437Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-17T19:36:47.656Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T08:28:21.776Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M340 CPU (part numbers BMXP34*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to sv3.60"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to sv4.20"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Control Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to v16.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Process Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to v2023"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n"
                }
              ],
              "value": "\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-924",
                  "description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-02-14T16:52:24.805Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-6408",
        "datePublished": "2024-02-14T16:52:24.805Z",
        "dateReserved": "2023-11-30T09:52:30.945Z",
        "dateUpdated": "2024-08-02T08:28:21.776Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-22786 (GCVE-0-2021-22786)

    Vulnerability from nvd – Published: 2023-02-01 00:00 – Updated: 2025-02-05 20:06
    VLAI
    Summary
    A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Date Public
    2022-08-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:51:07.574Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-221-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-221-04-Modicon_Controllers_Ethernet_Modules_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-22786",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:54:57.011597Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:06:44.280Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M340 CPU (part numbers BMXP34*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V3.30",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V3.20",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "product": "Modicon MC80 (BMKC80)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V1.6",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon Momentum CPU (171CBU*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V2.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Legacy Modicon Quantum",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            }
          ],
          "datePublic": "2022-08-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-01T00:00:00.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-221-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-221-04-Modicon_Controllers_Ethernet_Modules_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2021-22786",
        "datePublished": "2023-02-01T00:00:00.000Z",
        "dateReserved": "2021-01-06T00:00:00.000Z",
        "dateUpdated": "2025-02-05T20:06:44.280Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45789 (GCVE-0-2022-45789)

    Vulnerability from nvd – Published: 2023-01-31 00:00 – Updated: 2026-05-29 14:09
    VLAI
    Summary
    A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-294 - Authentication Bypass by Capture-Replay
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:17:04.077Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-06_Modicon_Controllers_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45789",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:52:21.864489Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:09:29.675Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Control Expert ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Process Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M340 CPU (part numbers BMXP34*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*) ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)\u003c/p\u003e"
                }
              ],
              "value": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-294",
                  "description": "CWE-294: Authentication Bypass by Capture-Replay",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-09T13:48:11.112Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-06_Modicon_Controllers_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-45789",
        "datePublished": "2023-01-31T00:00:00.000Z",
        "dateReserved": "2022-11-22T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:09:29.675Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-45788 (GCVE-0-2022-45788)

    Vulnerability from nvd – Published: 2023-01-30 00:00 – Updated: 2026-05-29 14:08
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:17:04.131Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-05_Modicon_Controllers_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45788",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:52:24.602959Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:08:52.615Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Control Expert ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Process Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M340 CPU (part numbers BMXP34*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*) ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Momentum Unity M1E Processor (171CBU*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon MC80 (BMKC80)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Legacy Modicon Quantum (140CPU65*) and Premium CPUs (TSXP57*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality \u0026amp; integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)\u003c/p\u003e"
                }
              ],
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality \u0026 integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-09T13:43:07.202Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-05_Modicon_Controllers_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-45788",
        "datePublished": "2023-01-30T00:00:00.000Z",
        "dateReserved": "2022-11-22T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:08:52.615Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-37301 (GCVE-0-2022-37301)

    Vulnerability from nvd – Published: 2022-11-22 00:00 – Updated: 2025-04-28 14:32
    VLAI
    Summary
    A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34*)(V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*)(V3.22 and prior), Legacy Modicon Quantum/Premium(All Versions), Modicon Momentum MDI (171CBU*)(All Versions), Modicon MC80 (BMKC80)(V1.7 and prior)
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-191 - Integer Underflow (Wrap or Wraparound)
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:29:20.468Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.se.com/us/en/download/document/SEVD-2022-221-02/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-37301",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-28T14:32:06.292092Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-28T14:32:19.547Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M340 CPU (part numbers BMXP34*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "3.40",
                  "status": "affected",
                  "version": "V",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*) ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "3.22",
                  "status": "affected",
                  "version": "V",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Legacy Modicon Quantum/Premium",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All  Versions"
                }
              ]
            },
            {
              "product": "Modicon Momentum MDI (171CBU*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All  Versions"
                }
              ]
            },
            {
              "product": "Modicon MC80 (BMKC80)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "1.7",
                  "status": "affected",
                  "version": "V",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34*)(V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*)(V3.22 and prior), Legacy Modicon Quantum/Premium(All Versions), Modicon Momentum MDI (171CBU*)(All Versions), Modicon MC80 (BMKC80)(V1.7 and prior)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-191",
                  "description": "CWE-191 Integer Underflow (Wrap or Wraparound)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-22T00:00:00.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://www.se.com/us/en/download/document/SEVD-2022-221-02/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-37301",
        "datePublished": "2022-11-22T00:00:00.000Z",
        "dateReserved": "2022-08-01T00:00:00.000Z",
        "dateUpdated": "2025-04-28T14:32:19.547Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-37300 (GCVE-0-2022-37300)

    Vulnerability from nvd – Published: 2022-09-12 17:40 – Updated: 2024-08-03 10:29
    VLAI
    Summary
    A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
    CWE
    • CWE-640 - Weak Password Recovery Mechanism for Forgotten Password
    Assigner
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:29:20.628Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/us/en/download/document/SEVD-2022-221-01/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Control Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "15.0",
                  "status": "affected",
                  "version": "SP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "EcoStruxure Process Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "2021",
                  "status": "affected",
                  "version": "V",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon M340 CPU",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "3.40",
                  "status": "affected",
                  "version": "BMXP34",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon M580 CPU",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "3.20",
                  "status": "affected",
                  "version": "BMEP",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "3.20",
                  "status": "affected",
                  "version": "BMEH",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior)."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-640",
                  "description": "CWE-640 Weak Password Recovery Mechanism for Forgotten Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-12T17:40:10.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/us/en/download/document/SEVD-2022-221-01/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2022-37300",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Control Expert",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "SP1",
                                "version_value": "15.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "EcoStruxure Process Expert",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "V",
                                "version_value": "2021"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Modicon M340 CPU",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "BMXP34",
                                "version_value": "3.40"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Modicon M580 CPU",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "BMEP",
                                "version_value": "3.20"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "BMEH",
                                "version_value": "3.20"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior)."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-640 Weak Password Recovery Mechanism for Forgotten Password"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/us/en/download/document/SEVD-2022-221-01/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/us/en/download/document/SEVD-2022-221-01/"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-37300",
        "datePublished": "2022-09-12T17:40:10.000Z",
        "dateReserved": "2022-08-01T00:00:00.000Z",
        "dateUpdated": "2024-08-03T10:29:20.628Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-22779 (GCVE-0-2021-22779)

    Vulnerability from nvd – Published: 2021-07-14 14:26 – Updated: 2026-05-29 13:50
    VLAI
    Summary
    Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-290 - Authentication Bypass by Spoofing
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*) Affected: EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:51:07.432Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-22779",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:49:49.378985Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:50:09.766Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-290",
                  "description": "CWE-290: Authentication Bypass by Spoofing",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-07-14T14:26:41.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2021-22779",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-290: Authentication Bypass by Spoofing"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01",
                  "refsource": "MISC",
                  "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2021-22779",
        "datePublished": "2021-07-14T14:26:41.000Z",
        "dateReserved": "2021-01-06T00:00:00.000Z",
        "dateUpdated": "2026-05-29T13:50:09.766Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2020-7543 (GCVE-0-2020-7543)

    Vulnerability from nvd – Published: 2020-12-11 00:52 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.
    Severity
    No CVSS data available.
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions) Affected: Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.525Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-11T00:52:21.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7543",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7543",
        "datePublished": "2020-12-11T00:52:21.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.525Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7542 (GCVE-0-2020-7542)

    Vulnerability from nvd – Published: 2020-12-11 00:52 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.
    Severity
    No CVSS data available.
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions) Affected: Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.616Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-11T00:52:14.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7542",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7542",
        "datePublished": "2020-12-11T00:52:14.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.616Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7537 (GCVE-0-2020-7537)

    Vulnerability from nvd – Published: 2020-12-11 00:51 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.
    Severity
    No CVSS data available.
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions) Affected: Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.484Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-11T00:51:52.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7537",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7537",
        "datePublished": "2020-12-11T00:51:52.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.484Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6855 (GCVE-0-2019-6855)

    Vulnerability from nvd – Published: 2020-01-06 22:56 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.
    Severity
    No CVSS data available.
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10) Affected: EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.396Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863: Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-05-13T18:30:05.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-02/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6855",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-863: Incorrect Authorization"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-02/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6855",
        "datePublished": "2020-01-06T22:56:58.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.396Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7838 (GCVE-0-2018-7838)

    Vulnerability from nvd – Published: 2019-07-15 20:49 – Updated: 2024-08-05 06:37
    VLAI
    Summary
    A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Modicon Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16 Affected: Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16
    Create a notification for this product.
    Date Public
    2019-07-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:37:59.463Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16",
              "vendor": "Modicon",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16"
                }
              ]
            }
          ],
          "datePublic": "2019-07-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119 Buffer Errors",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-15T20:49:01.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2018-7838",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Modicon"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-119 Buffer Errors"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-03",
                  "refsource": "MISC",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2018-7838",
        "datePublished": "2019-07-15T20:49:01.000Z",
        "dateReserved": "2018-03-08T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:37:59.463Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-6408 (GCVE-0-2023-6408)

    Vulnerability from cvelistv5 – Published: 2024-02-14 16:52 – Updated: 2024-08-02 08:28
    VLAI
    Summary
    CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric Modicon M340 CPU (part numbers BMXP34*) Affected: Versions prior to sv3.60
    Create a notification for this product.
    Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety) Affected: Versions prior to sv4.20
    Create a notification for this product.
    Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) Affected: All Versions
    Create a notification for this product.
    Schneider Electric EcoStruxure Control Expert Affected: Versions prior to v16.0
    Create a notification for this product.
    Schneider Electric EcoStruxure Process Expert Affected: Versions prior to v2023
    Create a notification for this product.
    schneider-electric modicon_m580_bmep585040_firmware Affected: 0 , < 4.20 (custom)
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    schneider-electric modicon_m340_bmxp342030h_firmware Affected: 0 , < 3.60 (custom)
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2010_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302cl_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2030_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030h_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    schneider-electric modicon_m580_bmeh586040s_firmware Affected: 0 , < * (custom)
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*
        cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "modicon_m580_bmep585040_firmware",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThan": "4.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2010_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302cl_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2030_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030h_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "modicon_m340_bmxp342030h_firmware",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThan": "3.60",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "modicon_m580_bmeh586040s_firmware",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-6408",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-17T19:15:41.696437Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-17T19:36:47.656Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T08:28:21.776Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M340 CPU (part numbers BMXP34*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to sv3.60"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to sv4.20"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Control Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to v16.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Process Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to v2023"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n"
                }
              ],
              "value": "\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-924",
                  "description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-02-14T16:52:24.805Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-6408",
        "datePublished": "2024-02-14T16:52:24.805Z",
        "dateReserved": "2023-11-30T09:52:30.945Z",
        "dateUpdated": "2024-08-02T08:28:21.776Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-22786 (GCVE-0-2021-22786)

    Vulnerability from cvelistv5 – Published: 2023-02-01 00:00 – Updated: 2025-02-05 20:06
    VLAI
    Summary
    A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Date Public
    2022-08-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:51:07.574Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-221-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-221-04-Modicon_Controllers_Ethernet_Modules_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-22786",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:54:57.011597Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:06:44.280Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M340 CPU (part numbers BMXP34*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V3.30",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V3.20",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "product": "Modicon MC80 (BMKC80)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V1.6",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon Momentum CPU (171CBU*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V2.3",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Legacy Modicon Quantum",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            }
          ],
          "datePublic": "2022-08-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-01T00:00:00.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-221-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-221-04-Modicon_Controllers_Ethernet_Modules_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2021-22786",
        "datePublished": "2023-02-01T00:00:00.000Z",
        "dateReserved": "2021-01-06T00:00:00.000Z",
        "dateUpdated": "2025-02-05T20:06:44.280Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45789 (GCVE-0-2022-45789)

    Vulnerability from cvelistv5 – Published: 2023-01-31 00:00 – Updated: 2026-05-29 14:09
    VLAI
    Summary
    A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-294 - Authentication Bypass by Capture-Replay
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:17:04.077Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-06_Modicon_Controllers_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45789",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:52:21.864489Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:09:29.675Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Control Expert ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Process Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M340 CPU (part numbers BMXP34*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*) ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)\u003c/p\u003e"
                }
              ],
              "value": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-294",
                  "description": "CWE-294: Authentication Bypass by Capture-Replay",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-09T13:48:11.112Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-06_Modicon_Controllers_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-45789",
        "datePublished": "2023-01-31T00:00:00.000Z",
        "dateReserved": "2022-11-22T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:09:29.675Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-45788 (GCVE-0-2022-45788)

    Vulnerability from cvelistv5 – Published: 2023-01-30 00:00 – Updated: 2026-05-29 14:08
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:17:04.131Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-05_Modicon_Controllers_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45788",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:52:24.602959Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:08:52.615Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Control Expert ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Process Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M340 CPU (part numbers BMXP34*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*) ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon Momentum Unity M1E Processor (171CBU*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Modicon MC80 (BMKC80)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Legacy Modicon Quantum (140CPU65*) and Premium CPUs (TSXP57*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality \u0026amp; integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)\u003c/p\u003e"
                }
              ],
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality \u0026 integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-09T13:43:07.202Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-05_Modicon_Controllers_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-45788",
        "datePublished": "2023-01-30T00:00:00.000Z",
        "dateReserved": "2022-11-22T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:08:52.615Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-37301 (GCVE-0-2022-37301)

    Vulnerability from cvelistv5 – Published: 2022-11-22 00:00 – Updated: 2025-04-28 14:32
    VLAI
    Summary
    A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34*)(V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*)(V3.22 and prior), Legacy Modicon Quantum/Premium(All Versions), Modicon Momentum MDI (171CBU*)(All Versions), Modicon MC80 (BMKC80)(V1.7 and prior)
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-191 - Integer Underflow (Wrap or Wraparound)
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:29:20.468Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.se.com/us/en/download/document/SEVD-2022-221-02/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-37301",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-28T14:32:06.292092Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-28T14:32:19.547Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M340 CPU (part numbers BMXP34*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "3.40",
                  "status": "affected",
                  "version": "V",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*) ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "3.22",
                  "status": "affected",
                  "version": "V",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Legacy Modicon Quantum/Premium",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All  Versions"
                }
              ]
            },
            {
              "product": "Modicon Momentum MDI (171CBU*)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All  Versions"
                }
              ]
            },
            {
              "product": "Modicon MC80 (BMKC80)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "1.7",
                  "status": "affected",
                  "version": "V",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34*)(V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*)(V3.22 and prior), Legacy Modicon Quantum/Premium(All Versions), Modicon Momentum MDI (171CBU*)(All Versions), Modicon MC80 (BMKC80)(V1.7 and prior)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-191",
                  "description": "CWE-191 Integer Underflow (Wrap or Wraparound)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-22T00:00:00.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://www.se.com/us/en/download/document/SEVD-2022-221-02/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-37301",
        "datePublished": "2022-11-22T00:00:00.000Z",
        "dateReserved": "2022-08-01T00:00:00.000Z",
        "dateUpdated": "2025-04-28T14:32:19.547Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-37300 (GCVE-0-2022-37300)

    Vulnerability from cvelistv5 – Published: 2022-09-12 17:40 – Updated: 2024-08-03 10:29
    VLAI
    Summary
    A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
    CWE
    • CWE-640 - Weak Password Recovery Mechanism for Forgotten Password
    Assigner
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T10:29:20.628Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/us/en/download/document/SEVD-2022-221-01/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Control Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "15.0",
                  "status": "affected",
                  "version": "SP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "EcoStruxure Process Expert",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "2021",
                  "status": "affected",
                  "version": "V",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon M340 CPU",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "3.40",
                  "status": "affected",
                  "version": "BMXP34",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Modicon M580 CPU",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "3.20",
                  "status": "affected",
                  "version": "BMEP",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "3.20",
                  "status": "affected",
                  "version": "BMEH",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior)."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-640",
                  "description": "CWE-640 Weak Password Recovery Mechanism for Forgotten Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-09-12T17:40:10.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/us/en/download/document/SEVD-2022-221-01/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2022-37300",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Control Expert",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "SP1",
                                "version_value": "15.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "EcoStruxure Process Expert",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "V",
                                "version_value": "2021"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Modicon M340 CPU",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "BMXP34",
                                "version_value": "3.40"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Modicon M580 CPU",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "BMEP",
                                "version_value": "3.20"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "BMEH",
                                "version_value": "3.20"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior)."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-640 Weak Password Recovery Mechanism for Forgotten Password"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/us/en/download/document/SEVD-2022-221-01/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/us/en/download/document/SEVD-2022-221-01/"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-37300",
        "datePublished": "2022-09-12T17:40:10.000Z",
        "dateReserved": "2022-08-01T00:00:00.000Z",
        "dateUpdated": "2024-08-03T10:29:20.628Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-22779 (GCVE-0-2021-22779)

    Vulnerability from cvelistv5 – Published: 2021-07-14 14:26 – Updated: 2026-05-29 13:50
    VLAI
    Summary
    Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-290 - Authentication Bypass by Spoofing
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*) Affected: EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:51:07.432Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-22779",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T13:49:49.378985Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T13:50:09.766Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-290",
                  "description": "CWE-290: Authentication Bypass by Spoofing",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-07-14T14:26:41.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2021-22779",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-290: Authentication Bypass by Spoofing"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01",
                  "refsource": "MISC",
                  "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2021-22779",
        "datePublished": "2021-07-14T14:26:41.000Z",
        "dateReserved": "2021-01-06T00:00:00.000Z",
        "dateUpdated": "2026-05-29T13:50:09.766Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2020-7543 (GCVE-0-2020-7543)

    Vulnerability from cvelistv5 – Published: 2020-12-11 00:52 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.
    Severity
    No CVSS data available.
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions) Affected: Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.525Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-11T00:52:21.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7543",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7543",
        "datePublished": "2020-12-11T00:52:21.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.525Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7542 (GCVE-0-2020-7542)

    Vulnerability from cvelistv5 – Published: 2020-12-11 00:52 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.
    Severity
    No CVSS data available.
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions) Affected: Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.616Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-11T00:52:14.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7542",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7542",
        "datePublished": "2020-12-11T00:52:14.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.616Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7537 (GCVE-0-2020-7537)

    Vulnerability from cvelistv5 – Published: 2020-12-11 00:51 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.
    Severity
    No CVSS data available.
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions) Affected: Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.484Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-11T00:51:52.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7537",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum \u0026 Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/",
                  "refsource": "CONFIRM",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-08/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7537",
        "datePublished": "2020-12-11T00:51:52.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.484Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-6855 (GCVE-0-2019-6855)

    Vulnerability from cvelistv5 – Published: 2020-01-06 22:56 – Updated: 2024-08-04 20:31
    VLAI
    Summary
    Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.
    Severity
    No CVSS data available.
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10) Affected: EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T20:31:04.396Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863: Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-05-13T18:30:05.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-02/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2019-6855",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-863: Incorrect Authorization"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-02/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2019-6855",
        "datePublished": "2020-01-06T22:56:58.000Z",
        "dateReserved": "2019-01-25T00:00:00.000Z",
        "dateUpdated": "2024-08-04T20:31:04.396Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7838 (GCVE-0-2018-7838)

    Vulnerability from cvelistv5 – Published: 2019-07-15 20:49 – Updated: 2024-08-05 06:37
    VLAI
    Summary
    A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Modicon Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16 Affected: Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16
    Create a notification for this product.
    Date Public
    2019-07-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:37:59.463Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16",
              "vendor": "Modicon",
              "versions": [
                {
                  "status": "affected",
                  "version": "Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16"
                }
              ]
            }
          ],
          "datePublic": "2019-07-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119 Buffer Errors",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-15T20:49:01.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2018-7838",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Modicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Modicon"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-119 Buffer Errors"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-03",
                  "refsource": "MISC",
                  "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2018-7838",
        "datePublished": "2019-07-15T20:49:01.000Z",
        "dateReserved": "2018-03-08T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:37:59.463Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }