    CVE-2020-14523 (GCVE-0-2020-14523)

    Vulnerability from nvd – Published: 2022-02-11 17:40 – Updated: 2025-04-16 18:01
    VLAI
    Title
    Mitsubishi Electric Factory Automation Products Path Traversal
    Summary
    Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Impacted products
    Vendor Product Version
    Mitsubishi Electric CW Configurator Affected: unspecified , ≤ Version 1.010L (custom)
    Create a notification for this product.
    Mitsubishi Electric FR Configurator2 Affected: unspecified , ≤ Version 1.22Y (custom)
    Create a notification for this product.
    Mitsubishi Electric GX Works2 Affected: unspecified , ≤ Version 1.595V (custom)
    Create a notification for this product.
    Mitsubishi Electric GX Works3 Affected: unspecified , ≤ Version 1.063R (custom)
    Create a notification for this product.
    Mitsubishi Electric MELSOFT iQ AppPortal Affected: unspecified , ≤ Version 1.17T (custom)
    Create a notification for this product.
    Mitsubishi Electric MELSOFT Navigator Affected: unspecified , ≤ Version2.70Y (custom)
    Create a notification for this product.
    Mitsubishi Electric MI Configurator Affected: All Versions
    Create a notification for this product.
    Mitsubishi Electric MR Configurator2 Affected: unspecified , ≤ Version 1.110Q (custom)
    Create a notification for this product.
    Mitsubishi Electric MT Works2 Affected: unspecified , ≤ Versions 1.156N (custom)
    Create a notification for this product.
    Mitsubishi Electric MX Component Affected: unspecified , ≤ Version 4.20W (custom)
    Create a notification for this product.
    Mitsubishi Electric RT ToolBox3 Affected: unspecified , ≤ Versions 1.70Y (custom)
    Create a notification for this product.
    Mitsubishi Electric MELSEC iQ-R Series Motion Module Affected: unspecified , ≤ Versions 10 (custom)
    Create a notification for this product.
    Date Public
    2020-07-30 00:00
    Credits
    Mashav Sapir of Claroty reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T12:46:34.640Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU90224831/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-14523",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:31:26.782063Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T18:01:22.616Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CW Configurator",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.010L",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "FR Configurator2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.22Y",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "GX Works2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.595V",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "GX Works3",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.063R",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MELSOFT iQ AppPortal",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.17T",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MELSOFT Navigator",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version2.70Y",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MI Configurator",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "product": "MR Configurator2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.110Q",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MT Works2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Versions 1.156N",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MX Component",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 4.20W",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "RT ToolBox3",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Versions 1.70Y",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MELSEC iQ-R Series Motion Module",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Versions 10",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
            }
          ],
          "datePublic": "2020-07-30T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-18T23:17:23.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU90224831/"
            }
          ],
          "source": {
            "advisory": "ICSA-20-212-03",
            "discovery": "UNKNOWN"
          },
          "title": "Mitsubishi Electric Factory Automation Products Path Traversal",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2020-07-30T16:50:00.000Z",
              "ID": "CVE-2020-14523",
              "STATE": "PUBLIC",
              "TITLE": "Mitsubishi Electric Factory Automation Products Path Traversal"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CW Configurator",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.010L"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "FR Configurator2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.22Y"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "GX Works2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.595V"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "GX Works3",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.063R"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MELSOFT iQ AppPortal",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.17T"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MELSOFT Navigator",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version2.70Y"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MI Configurator",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "All Versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MR Configurator2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.110Q"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MT Works2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Versions 1.156N"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MX Component",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 4.20W"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "RT ToolBox3",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Versions 1.70Y"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MELSEC iQ-R Series Motion Module",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Versions 10"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU90224831/",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU90224831/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en"
              }
            ],
            "source": {
              "advisory": "ICSA-20-212-03",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-14523",
        "datePublished": "2022-02-11T17:40:29.187Z",
        "dateReserved": "2020-06-19T00:00:00.000Z",
        "dateUpdated": "2025-04-16T18:01:22.616Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-14523 (GCVE-0-2020-14523)

    Vulnerability from cvelistv5 – Published: 2022-02-11 17:40 – Updated: 2025-04-16 18:01
    VLAI
    Title
    Mitsubishi Electric Factory Automation Products Path Traversal
    Summary
    Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Impacted products
    Vendor Product Version
    Mitsubishi Electric CW Configurator Affected: unspecified , ≤ Version 1.010L (custom)
    Create a notification for this product.
    Mitsubishi Electric FR Configurator2 Affected: unspecified , ≤ Version 1.22Y (custom)
    Create a notification for this product.
    Mitsubishi Electric GX Works2 Affected: unspecified , ≤ Version 1.595V (custom)
    Create a notification for this product.
    Mitsubishi Electric GX Works3 Affected: unspecified , ≤ Version 1.063R (custom)
    Create a notification for this product.
    Mitsubishi Electric MELSOFT iQ AppPortal Affected: unspecified , ≤ Version 1.17T (custom)
    Create a notification for this product.
    Mitsubishi Electric MELSOFT Navigator Affected: unspecified , ≤ Version2.70Y (custom)
    Create a notification for this product.
    Mitsubishi Electric MI Configurator Affected: All Versions
    Create a notification for this product.
    Mitsubishi Electric MR Configurator2 Affected: unspecified , ≤ Version 1.110Q (custom)
    Create a notification for this product.
    Mitsubishi Electric MT Works2 Affected: unspecified , ≤ Versions 1.156N (custom)
    Create a notification for this product.
    Mitsubishi Electric MX Component Affected: unspecified , ≤ Version 4.20W (custom)
    Create a notification for this product.
    Mitsubishi Electric RT ToolBox3 Affected: unspecified , ≤ Versions 1.70Y (custom)
    Create a notification for this product.
    Mitsubishi Electric MELSEC iQ-R Series Motion Module Affected: unspecified , ≤ Versions 10 (custom)
    Create a notification for this product.
    Date Public
    2020-07-30 00:00
    Credits
    Mashav Sapir of Claroty reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T12:46:34.640Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU90224831/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-14523",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:31:26.782063Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T18:01:22.616Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CW Configurator",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.010L",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "FR Configurator2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.22Y",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "GX Works2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.595V",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "GX Works3",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.063R",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MELSOFT iQ AppPortal",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.17T",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MELSOFT Navigator",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version2.70Y",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MI Configurator",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "product": "MR Configurator2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.110Q",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MT Works2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Versions 1.156N",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MX Component",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 4.20W",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "RT ToolBox3",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Versions 1.70Y",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MELSEC iQ-R Series Motion Module",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Versions 10",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
            }
          ],
          "datePublic": "2020-07-30T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-18T23:17:23.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU90224831/"
            }
          ],
          "source": {
            "advisory": "ICSA-20-212-03",
            "discovery": "UNKNOWN"
          },
          "title": "Mitsubishi Electric Factory Automation Products Path Traversal",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2020-07-30T16:50:00.000Z",
              "ID": "CVE-2020-14523",
              "STATE": "PUBLIC",
              "TITLE": "Mitsubishi Electric Factory Automation Products Path Traversal"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CW Configurator",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.010L"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "FR Configurator2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.22Y"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "GX Works2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.595V"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "GX Works3",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.063R"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MELSOFT iQ AppPortal",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.17T"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MELSOFT Navigator",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version2.70Y"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MI Configurator",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "All Versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MR Configurator2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.110Q"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MT Works2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Versions 1.156N"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MX Component",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 4.20W"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "RT ToolBox3",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Versions 1.70Y"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MELSEC iQ-R Series Motion Module",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Versions 10"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU90224831/",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU90224831/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en"
              }
            ],
            "source": {
              "advisory": "ICSA-20-212-03",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-14523",
        "datePublished": "2022-02-11T17:40:29.187Z",
        "dateReserved": "2020-06-19T00:00:00.000Z",
        "dateUpdated": "2025-04-16T18:01:22.616Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }