Search
Find a vulnerability
Search criteria
14 vulnerabilities found for i6_firmware by tenda
CVE-2026-6024 (GCVE-0-2026-6024)
Vulnerability from nvd – Published: 2026-04-10 05:15 – Updated: 2026-04-10 15:54
VLAI
Title
Tenda i6 HTTP R7WebsSecurityHandlerfunction path traversal
Summary
A vulnerability was determined in Tenda i6 1.0.0.7(2204). Affected by this issue is the function R7WebsSecurityHandlerfunction of the component HTTP Handler. This manipulation causes path traversal. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-22 - Path Traversal
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/356600 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/356600/cti | signaturepermissions-required |
| https://vuldb.com/submit/791826 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-6024",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-10T15:46:22.558447Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-10T15:54:20.628Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP Handler"
],
"product": "i6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.7(2204)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda i6 1.0.0.7(2204). Affected by this issue is the function R7WebsSecurityHandlerfunction of the component HTTP Handler. This manipulation causes path traversal. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "Path Traversal",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-10T05:15:13.771Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-356600 | Tenda i6 HTTP R7WebsSecurityHandlerfunction path traversal",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/356600"
},
{
"name": "VDB-356600 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/356600/cti"
},
{
"name": "Submit #791826 | Tenda i6 V1.0.0.7(2204) Path Traversal",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/791826"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/M3/vul_84/README.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-09T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-09T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-09T17:56:44.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i6 HTTP R7WebsSecurityHandlerfunction path traversal"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-6024",
"datePublished": "2026-04-10T05:15:13.771Z",
"dateReserved": "2026-04-09T15:51:37.912Z",
"dateUpdated": "2026-04-10T15:54:20.628Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-0993 (GCVE-0-2024-0993)
Vulnerability from nvd – Published: 2024-01-29 01:31 – Updated: 2025-05-29 15:10
VLAI
Title
Tenda i6 httpd WifiMacFilterGet formWifiMacFilterGet stack-based overflow
Summary
A vulnerability was found in Tenda i6 1.0.0.9(3857). It has been classified as critical. Affected is the function formWifiMacFilterGet of the file /goform/WifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-252258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
7.2 (High)
7.2 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.252258 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.252258 | signaturepermissions-required |
| https://jylsec.notion.site/Tenda-i6-has-stack-buf… | exploit |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.359Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252258"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252258"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formWifiMacFilterGet-8b2c5cb67e2a433cad62d737782a7e0f?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0993",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T15:35:48.646745Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-29T15:10:23.451Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "i6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(3857)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda i6 1.0.0.9(3857). It has been classified as critical. Affected is the function formWifiMacFilterGet of the file /goform/WifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-252258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda i6 1.0.0.9(3857) ausgemacht. Dabei betrifft es die Funktion formWifiMacFilterGet der Datei /goform/WifiMacFilterGet der Komponente httpd. Mittels Manipulieren des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T01:31:04.198Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252258"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252258"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formWifiMacFilterGet-8b2c5cb67e2a433cad62d737782a7e0f?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:44:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i6 httpd WifiMacFilterGet formWifiMacFilterGet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0993",
"datePublished": "2024-01-29T01:31:04.198Z",
"dateReserved": "2024-01-28T15:39:31.365Z",
"dateUpdated": "2025-05-29T15:10:23.451Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0992 (GCVE-0-2024-0992)
Vulnerability from nvd – Published: 2024-01-29 01:00 – Updated: 2025-06-16 18:32
VLAI
Title
Tenda i6 httpd wifiSSIDset formwrlSSIDset stack-based overflow
Summary
A vulnerability was found in Tenda i6 1.0.0.9(3857) and classified as critical. This issue affects the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252257 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
7.2 (High)
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.252257 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.252257 | signaturepermissions-required |
| https://jylsec.notion.site/Tenda-i6-has-stack-buf… | exploit |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.161Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252257"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252257"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-f0e8be2eb0614e03a60160b48f8527f5?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0992",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-16T18:32:26.431635Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-16T18:32:44.905Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "i6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(3857)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda i6 1.0.0.9(3857) and classified as critical. This issue affects the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252257 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda i6 1.0.0.9(3857) gefunden. Dies betrifft die Funktion formwrlSSIDset der Datei /goform/wifiSSIDset der Komponente httpd. Mittels dem Manipulieren des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T01:00:06.960Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252257"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252257"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-f0e8be2eb0614e03a60160b48f8527f5?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:44:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i6 httpd wifiSSIDset formwrlSSIDset stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0992",
"datePublished": "2024-01-29T01:00:06.960Z",
"dateReserved": "2024-01-28T15:39:27.874Z",
"dateUpdated": "2025-06-16T18:32:44.905Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0991 (GCVE-0-2024-0991)
Vulnerability from nvd – Published: 2024-01-29 01:00 – Updated: 2024-10-18 14:27
VLAI
Title
Tenda i6 httpd setcfm formSetCfm stack-based overflow
Summary
A vulnerability has been found in Tenda i6 1.0.0.9(3857) and classified as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252256. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
7.2 (High)
7.2 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.252256 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.252256 | signaturepermissions-required |
| https://jylsec.notion.site/Tenda-i6-has-stack-buf… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.368Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252256"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252256"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formSetCfm-9c9952ba7216422c8188e75c94bb531a?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:i6:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "i6",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9\\/3857\\/"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0991",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-18T14:25:19.066242Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-18T14:27:27.141Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "i6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(3857)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda i6 1.0.0.9(3857) and classified as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252256. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda i6 1.0.0.9(3857) wurde eine kritische Schwachstelle gefunden. Das betrifft die Funktion formSetCfm der Datei /goform/setcfm der Komponente httpd. Durch Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T01:00:05.851Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252256"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252256"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formSetCfm-9c9952ba7216422c8188e75c94bb531a?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:44:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i6 httpd setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0991",
"datePublished": "2024-01-29T01:00:05.851Z",
"dateReserved": "2024-01-28T15:39:24.545Z",
"dateUpdated": "2024-10-18T14:27:27.141Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0990 (GCVE-0-2024-0990)
Vulnerability from nvd – Published: 2024-01-29 00:31 – Updated: 2024-08-28 15:29
VLAI
Title
Tenda i6 httpd setAutoPing formSetAutoPing stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda i6 1.0.0.9(3857). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component httpd. The manipulation of the argument ping1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
7.2 (High)
7.2 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.252255 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.252255 | signaturepermissions-required |
| https://jylsec.notion.site/Tenda-i6-has-stack-buf… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | i6 |
Affected:
1.0.0.9(3857)
|
|
| tenda | i6_firmware |
Affected:
1.0.0.9\(3857\)
cpe:2.3:o:tenda:i6_firmware:1.0.0.9\(3857\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.159Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252255"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252255"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formSetAutoPing-2e009d81eb7e45438565d5ba6794f4e3?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:i6_firmware:1.0.0.9\\(3857\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "i6_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9\\(3857\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0990",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-28T15:27:21.030567Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T15:29:07.382Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "i6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(3857)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda i6 1.0.0.9(3857). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component httpd. The manipulation of the argument ping1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda i6 1.0.0.9(3857) gefunden. Es betrifft die Funktion formSetAutoPing der Datei /goform/setAutoPing der Komponente httpd. Durch die Manipulation des Arguments ping1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T00:31:04.988Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252255"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252255"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formSetAutoPing-2e009d81eb7e45438565d5ba6794f4e3?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:44:52.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i6 httpd setAutoPing formSetAutoPing stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0990",
"datePublished": "2024-01-29T00:31:04.988Z",
"dateReserved": "2024-01-28T15:39:22.058Z",
"dateUpdated": "2024-08-28T15:29:07.382Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48964 (GCVE-0-2023-48964)
Vulnerability from nvd – Published: 2023-11-30 00:00 – Updated: 2024-08-02 21:46
VLAI
Summary
Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/WifiMacFilterSet.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:46:28.751Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/daodaoshao/vul_tenda_i6_2"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/WifiMacFilterSet."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-30T13:16:44.590Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/daodaoshao/vul_tenda_i6_2"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-48964",
"datePublished": "2023-11-30T00:00:00.000Z",
"dateReserved": "2023-11-20T00:00:00.000Z",
"dateUpdated": "2024-08-02T21:46:28.751Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48963 (GCVE-0-2023-48963)
Vulnerability from nvd – Published: 2023-11-30 00:00 – Updated: 2024-08-02 21:46
VLAI
Summary
Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/wifiSSIDget.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:46:29.039Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/daodaoshao/vul_tenda_i6_1"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/wifiSSIDget."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-30T13:19:25.557Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/daodaoshao/vul_tenda_i6_1"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-48963",
"datePublished": "2023-11-30T00:00:00.000Z",
"dateReserved": "2023-11-20T00:00:00.000Z",
"dateUpdated": "2024-08-02T21:46:29.039Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-6024 (GCVE-0-2026-6024)
Vulnerability from cvelistv5 – Published: 2026-04-10 05:15 – Updated: 2026-04-10 15:54
VLAI
Title
Tenda i6 HTTP R7WebsSecurityHandlerfunction path traversal
Summary
A vulnerability was determined in Tenda i6 1.0.0.7(2204). Affected by this issue is the function R7WebsSecurityHandlerfunction of the component HTTP Handler. This manipulation causes path traversal. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-22 - Path Traversal
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/356600 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/356600/cti | signaturepermissions-required |
| https://vuldb.com/submit/791826 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-6024",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-10T15:46:22.558447Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-10T15:54:20.628Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP Handler"
],
"product": "i6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.7(2204)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda i6 1.0.0.7(2204). Affected by this issue is the function R7WebsSecurityHandlerfunction of the component HTTP Handler. This manipulation causes path traversal. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "Path Traversal",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-10T05:15:13.771Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-356600 | Tenda i6 HTTP R7WebsSecurityHandlerfunction path traversal",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/356600"
},
{
"name": "VDB-356600 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/356600/cti"
},
{
"name": "Submit #791826 | Tenda i6 V1.0.0.7(2204) Path Traversal",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/791826"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/M3/vul_84/README.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-09T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-09T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-09T17:56:44.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i6 HTTP R7WebsSecurityHandlerfunction path traversal"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-6024",
"datePublished": "2026-04-10T05:15:13.771Z",
"dateReserved": "2026-04-09T15:51:37.912Z",
"dateUpdated": "2026-04-10T15:54:20.628Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-0993 (GCVE-0-2024-0993)
Vulnerability from cvelistv5 – Published: 2024-01-29 01:31 – Updated: 2025-05-29 15:10
VLAI
Title
Tenda i6 httpd WifiMacFilterGet formWifiMacFilterGet stack-based overflow
Summary
A vulnerability was found in Tenda i6 1.0.0.9(3857). It has been classified as critical. Affected is the function formWifiMacFilterGet of the file /goform/WifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-252258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
7.2 (High)
7.2 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.252258 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.252258 | signaturepermissions-required |
| https://jylsec.notion.site/Tenda-i6-has-stack-buf… | exploit |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.359Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252258"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252258"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formWifiMacFilterGet-8b2c5cb67e2a433cad62d737782a7e0f?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0993",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T15:35:48.646745Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-29T15:10:23.451Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "i6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(3857)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda i6 1.0.0.9(3857). It has been classified as critical. Affected is the function formWifiMacFilterGet of the file /goform/WifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-252258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda i6 1.0.0.9(3857) ausgemacht. Dabei betrifft es die Funktion formWifiMacFilterGet der Datei /goform/WifiMacFilterGet der Komponente httpd. Mittels Manipulieren des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T01:31:04.198Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252258"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252258"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formWifiMacFilterGet-8b2c5cb67e2a433cad62d737782a7e0f?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:44:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i6 httpd WifiMacFilterGet formWifiMacFilterGet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0993",
"datePublished": "2024-01-29T01:31:04.198Z",
"dateReserved": "2024-01-28T15:39:31.365Z",
"dateUpdated": "2025-05-29T15:10:23.451Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0992 (GCVE-0-2024-0992)
Vulnerability from cvelistv5 – Published: 2024-01-29 01:00 – Updated: 2025-06-16 18:32
VLAI
Title
Tenda i6 httpd wifiSSIDset formwrlSSIDset stack-based overflow
Summary
A vulnerability was found in Tenda i6 1.0.0.9(3857) and classified as critical. This issue affects the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252257 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
7.2 (High)
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.252257 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.252257 | signaturepermissions-required |
| https://jylsec.notion.site/Tenda-i6-has-stack-buf… | exploit |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.161Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252257"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252257"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-f0e8be2eb0614e03a60160b48f8527f5?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0992",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-16T18:32:26.431635Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-16T18:32:44.905Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "i6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(3857)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda i6 1.0.0.9(3857) and classified as critical. This issue affects the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252257 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda i6 1.0.0.9(3857) gefunden. Dies betrifft die Funktion formwrlSSIDset der Datei /goform/wifiSSIDset der Komponente httpd. Mittels dem Manipulieren des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T01:00:06.960Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252257"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252257"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-f0e8be2eb0614e03a60160b48f8527f5?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:44:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i6 httpd wifiSSIDset formwrlSSIDset stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0992",
"datePublished": "2024-01-29T01:00:06.960Z",
"dateReserved": "2024-01-28T15:39:27.874Z",
"dateUpdated": "2025-06-16T18:32:44.905Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0991 (GCVE-0-2024-0991)
Vulnerability from cvelistv5 – Published: 2024-01-29 01:00 – Updated: 2024-10-18 14:27
VLAI
Title
Tenda i6 httpd setcfm formSetCfm stack-based overflow
Summary
A vulnerability has been found in Tenda i6 1.0.0.9(3857) and classified as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252256. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
7.2 (High)
7.2 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.252256 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.252256 | signaturepermissions-required |
| https://jylsec.notion.site/Tenda-i6-has-stack-buf… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.368Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252256"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252256"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formSetCfm-9c9952ba7216422c8188e75c94bb531a?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:i6:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "i6",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9\\/3857\\/"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0991",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-18T14:25:19.066242Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-18T14:27:27.141Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "i6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(3857)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda i6 1.0.0.9(3857) and classified as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252256. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda i6 1.0.0.9(3857) wurde eine kritische Schwachstelle gefunden. Das betrifft die Funktion formSetCfm der Datei /goform/setcfm der Komponente httpd. Durch Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T01:00:05.851Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252256"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252256"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formSetCfm-9c9952ba7216422c8188e75c94bb531a?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:44:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i6 httpd setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0991",
"datePublished": "2024-01-29T01:00:05.851Z",
"dateReserved": "2024-01-28T15:39:24.545Z",
"dateUpdated": "2024-10-18T14:27:27.141Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0990 (GCVE-0-2024-0990)
Vulnerability from cvelistv5 – Published: 2024-01-29 00:31 – Updated: 2024-08-28 15:29
VLAI
Title
Tenda i6 httpd setAutoPing formSetAutoPing stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda i6 1.0.0.9(3857). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component httpd. The manipulation of the argument ping1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
7.2 (High)
7.2 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.252255 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.252255 | signaturepermissions-required |
| https://jylsec.notion.site/Tenda-i6-has-stack-buf… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | i6 |
Affected:
1.0.0.9(3857)
|
|
| tenda | i6_firmware |
Affected:
1.0.0.9\(3857\)
cpe:2.3:o:tenda:i6_firmware:1.0.0.9\(3857\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:26:30.159Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.252255"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.252255"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formSetAutoPing-2e009d81eb7e45438565d5ba6794f4e3?pvs=4"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:i6_firmware:1.0.0.9\\(3857\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "i6_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9\\(3857\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0990",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-28T15:27:21.030567Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T15:29:07.382Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "i6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.9(3857)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda i6 1.0.0.9(3857). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component httpd. The manipulation of the argument ping1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda i6 1.0.0.9(3857) gefunden. Es betrifft die Funktion formSetAutoPing der Datei /goform/setAutoPing der Komponente httpd. Durch die Manipulation des Arguments ping1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-29T00:31:04.988Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.252255"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.252255"
},
{
"tags": [
"exploit"
],
"url": "https://jylsec.notion.site/Tenda-i6-has-stack-buffer-overflow-vulnerability-in-formSetAutoPing-2e009d81eb7e45438565d5ba6794f4e3?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-01-28T16:44:52.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i6 httpd setAutoPing formSetAutoPing stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-0990",
"datePublished": "2024-01-29T00:31:04.988Z",
"dateReserved": "2024-01-28T15:39:22.058Z",
"dateUpdated": "2024-08-28T15:29:07.382Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48963 (GCVE-0-2023-48963)
Vulnerability from cvelistv5 – Published: 2023-11-30 00:00 – Updated: 2024-08-02 21:46
VLAI
Summary
Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/wifiSSIDget.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:46:29.039Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/daodaoshao/vul_tenda_i6_1"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/wifiSSIDget."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-30T13:19:25.557Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/daodaoshao/vul_tenda_i6_1"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-48963",
"datePublished": "2023-11-30T00:00:00.000Z",
"dateReserved": "2023-11-20T00:00:00.000Z",
"dateUpdated": "2024-08-02T21:46:29.039Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48964 (GCVE-0-2023-48964)
Vulnerability from cvelistv5 – Published: 2023-11-30 00:00 – Updated: 2024-08-02 21:46
VLAI
Summary
Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/WifiMacFilterSet.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:46:28.751Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/daodaoshao/vul_tenda_i6_2"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/WifiMacFilterSet."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-30T13:16:44.590Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/daodaoshao/vul_tenda_i6_2"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-48964",
"datePublished": "2023-11-30T00:00:00.000Z",
"dateReserved": "2023-11-20T00:00:00.000Z",
"dateUpdated": "2024-08-02T21:46:28.751Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}