    A vulnerability was detected in Tenda i22 1.0.0.3(4687). This impacts the function formWeixinAuthInfoGet of the file /goform/wxportalauth. Performing manipulation of the argument Type results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used. Shenzhen Tenda Technology Co.,Ltd. of i22 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202508-2066",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "i22  firmware  1.0.0.3(4687)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-012880"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9297"
          }
        ]
      },
      "cve": "CVE-2025-9297",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-9297",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-012880",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-9297",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-012880",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-9297",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-012880",
                "trust": 0.8,
                "value": "High"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-012880"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9297"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was detected in Tenda i22 1.0.0.3(4687). This impacts the function formWeixinAuthInfoGet of the file /goform/wxportalauth. Performing manipulation of the argument Type results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used. Shenzhen Tenda Technology Co.,Ltd. of i22 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-9297"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-012880"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-9297",
            "trust": 2.6
          },
          {
            "db": "VULDB",
            "id": "320902",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-012880",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-012880"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9297"
          }
        ]
      },
      "id": "VAR-202508-2066",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.56363636
      },
      "last_update_date": "2025-09-07T23:10:52.727000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-012880"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9297"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/davybat/iot-vuls/blob/main/tenda/formweixinauthinfoget.md"
          },
          {
            "trust": 1.8,
            "url": "https://github.com/davybat/iot-vuls/blob/main/tenda/formweixinauthinfoget.md#poc"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.320902"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.632332"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.320902"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-9297"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-012880"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9297"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-012880"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9297"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-04T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-012880"
          },
          {
            "date": "2025-08-21T13:15:37.067000",
            "db": "NVD",
            "id": "CVE-2025-9297"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-04T05:51:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-012880"
          },
          {
            "date": "2025-09-03T14:59:33.497000",
            "db": "NVD",
            "id": "CVE-2025-9297"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i22\u00a0 Buffer error vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-012880"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202408-0203

    Vulnerability from variot - Updated: 2025-05-28 23:23

    A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i22 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202408-0203",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "i22  firmware  1.0.0.3(4687)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10779"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005117"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7583"
          }
        ]
      },
      "cve": "CVE-2024-7583",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-7583",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-005117",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-10779",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-7583",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-7583",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-005117",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-7583",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-7583",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-005117",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-10779",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10779"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005117"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7583"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7583"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i22 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-7583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005117"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10779"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-7583",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "273863",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005117",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10779",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10779"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005117"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7583"
          }
        ]
      },
      "id": "VAR-202408-0203",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10779"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10779"
          }
        ]
      },
      "last_update_date": "2025-05-28T23:23:05.814000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005117"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7583"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/beacox/iot_vuln/tree/main/tenda/i22/apportalonekeyauth"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.273863"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.382835"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-7583"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.273863"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10779"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005117"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7583"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10779"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005117"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7583"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-26T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10779"
          },
          {
            "date": "2024-08-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-005117"
          },
          {
            "date": "2024-08-07T16:15:48.273000",
            "db": "NVD",
            "id": "CVE-2024-7583"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-27T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10779"
          },
          {
            "date": "2024-08-13T01:39:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-005117"
          },
          {
            "date": "2024-08-08T20:54:35.117000",
            "db": "NVD",
            "id": "CVE-2024-7583"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i22\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005117"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202408-0232

    Vulnerability from variot - Updated: 2025-05-28 23:17

    A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i22 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202408-0232",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "i22  firmware  1.0.0.3(4687)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10778"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005118"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7582"
          }
        ]
      },
      "cve": "CVE-2024-7582",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-7582",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-005118",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-10778",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-7582",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-7582",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-005118",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-7582",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-7582",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-005118",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-10778",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10778"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005118"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7582"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7582"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i22 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-7582"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005118"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10778"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-7582",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "273862",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005118",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10778",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10778"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005118"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7582"
          }
        ]
      },
      "id": "VAR-202408-0232",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10778"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10778"
          }
        ]
      },
      "last_update_date": "2025-05-28T23:17:06.247000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005118"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7582"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/beacox/iot_vuln/tree/main/tenda/i22/apportalaccesscodeauth"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.273862"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.382834"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-7582"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.273862"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10778"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005118"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7582"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10778"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005118"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7582"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-26T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10778"
          },
          {
            "date": "2024-08-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-005118"
          },
          {
            "date": "2024-08-07T16:15:47.873000",
            "db": "NVD",
            "id": "CVE-2024-7582"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-27T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10778"
          },
          {
            "date": "2024-08-13T01:39:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-005118"
          },
          {
            "date": "2024-08-08T20:55:07.530000",
            "db": "NVD",
            "id": "CVE-2024-7582"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i22\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-005118"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202212-0351

    Vulnerability from variot - Updated: 2025-04-25 01:55

    Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the formWx3AuthorizeSet function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0351",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13081"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45672"
          }
        ]
      },
      "cve": "CVE-2022-45672",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-13081",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45672",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45672",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45672",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-13081",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-1874",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13081"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1874"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45672"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45672"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the formWx3AuthorizeSet function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45672"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13081"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45672"
          }
        ],
        "trust": 1.53
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45672",
            "trust": 2.3
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13081",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1874",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45672",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13081"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45672"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1874"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45672"
          }
        ]
      },
      "id": "VAR-202212-0351",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13081"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13081"
          }
        ]
      },
      "last_update_date": "2025-04-25T01:55:32.537000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45672"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/double-q1015/cve-vulns/blob/main/tenda_i22/formwx3authorizeset/formwx3authorizeset.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45672"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45672/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13081"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45672"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1874"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45672"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13081"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45672"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1874"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45672"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13081"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45672"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1874"
          },
          {
            "date": "2022-12-02T18:15:12.560000",
            "db": "NVD",
            "id": "CVE-2022-45672"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13081"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45672"
          },
          {
            "date": "2022-12-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1874"
          },
          {
            "date": "2025-04-24T16:15:23.383000",
            "db": "NVD",
            "id": "CVE-2022-45672"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1874"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 formWx3AuthorizeSet function buffer overflow vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13081"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1874"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0118

    Vulnerability from variot - Updated: 2025-04-25 01:52

    Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the list parameter in the formwrlSSIDget function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0118",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13082"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45664"
          }
        ]
      },
      "cve": "CVE-2022-45664",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-13082",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45664",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45664",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45664",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-13082",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-1885",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13082"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1885"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45664"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45664"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the list parameter in the formwrlSSIDget function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45664"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13082"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45664"
          }
        ],
        "trust": 1.53
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45664",
            "trust": 2.3
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13082",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1885",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45664",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13082"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45664"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1885"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45664"
          }
        ]
      },
      "id": "VAR-202212-0118",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13082"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13082"
          }
        ]
      },
      "last_update_date": "2025-04-25T01:52:59.077000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45664"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/double-q1015/cve-vulns/blob/main/tenda_i22/formwrlssidget/formwifimacfilterget.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45664"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45664/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13082"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45664"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1885"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45664"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13082"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45664"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1885"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45664"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13082"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45664"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1885"
          },
          {
            "date": "2022-12-02T18:15:12.140000",
            "db": "NVD",
            "id": "CVE-2022-45664"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13082"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45664"
          },
          {
            "date": "2022-12-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1885"
          },
          {
            "date": "2025-04-24T16:15:22.430000",
            "db": "NVD",
            "id": "CVE-2022-45664"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1885"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 formwrlSSIDget function buffer overflow vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13082"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1885"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0114

    Vulnerability from variot - Updated: 2025-04-25 01:51

    Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the appData parameter in the formSetAppFilterRule function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0114",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13086"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45671"
          }
        ]
      },
      "cve": "CVE-2022-45671",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-13086",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45671",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45671",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45671",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-13086",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-1873",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13086"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1873"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45671"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45671"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the appData parameter in the formSetAppFilterRule function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45671"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13086"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45671"
          }
        ],
        "trust": 1.53
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45671",
            "trust": 2.3
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13086",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1873",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45671",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13086"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45671"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1873"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45671"
          }
        ]
      },
      "id": "VAR-202212-0114",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13086"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13086"
          }
        ]
      },
      "last_update_date": "2025-04-25T01:51:40.354000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45671"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/double-q1015/cve-vulns/blob/main/tenda_i22/formsetappfilterrule/formsetappfilterrule.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45671"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45671/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13086"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45671"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1873"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45671"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13086"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45671"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1873"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45671"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13086"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45671"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1873"
          },
          {
            "date": "2022-12-02T18:15:12.493000",
            "db": "NVD",
            "id": "CVE-2022-45671"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13086"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45671"
          },
          {
            "date": "2022-12-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1873"
          },
          {
            "date": "2025-04-24T16:15:23.203000",
            "db": "NVD",
            "id": "CVE-2022-45671"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1873"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 formSetAppFilterRule function buffer overflow vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13086"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1873"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0350

    Vulnerability from variot - Updated: 2025-04-25 01:50

    Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the index parameter in the formWifiMacFilterGet function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0350",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13084"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45669"
          }
        ]
      },
      "cve": "CVE-2022-45669",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-13084",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45669",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45669",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45669",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-13084",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-1876",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13084"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1876"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45669"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45669"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the index parameter in the formWifiMacFilterGet function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45669"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13084"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45669"
          }
        ],
        "trust": 1.53
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45669",
            "trust": 2.3
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13084",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1876",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45669",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13084"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45669"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1876"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45669"
          }
        ]
      },
      "id": "VAR-202212-0350",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13084"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13084"
          }
        ]
      },
      "last_update_date": "2025-04-25T01:50:14.380000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45669"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/confusedchensir/vulnerabilityprojectrecords/blob/main/formwifimacfilterget/formwifimacfilterget.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45669"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45669/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13084"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45669"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1876"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45669"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13084"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45669"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1876"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45669"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13084"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45669"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1876"
          },
          {
            "date": "2022-12-02T18:15:12.383000",
            "db": "NVD",
            "id": "CVE-2022-45669"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13084"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45669"
          },
          {
            "date": "2022-12-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1876"
          },
          {
            "date": "2025-04-24T16:15:22.820000",
            "db": "NVD",
            "id": "CVE-2022-45669"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1876"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 formWifiMacFilterGet function buffer overflow vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13084"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1876"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0214

    Vulnerability from variot - Updated: 2025-04-25 01:43

    Tenda i22 V1.0.0.3(4687) is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolReboot

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0214",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45668"
          }
        ]
      },
      "cve": "CVE-2022-45668",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2022-45668",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45668",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45668",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-1878",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1878"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45668"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45668"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 V1.0.0.3(4687) is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolReboot",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45668"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45668"
          }
        ],
        "trust": 0.99
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45668",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1878",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45668",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2022-45668"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1878"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45668"
          }
        ]
      },
      "id": "VAR-202212-0214",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.56363636
      },
      "last_update_date": "2025-04-25T01:43:21.649000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-352",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45668"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/double-q1015/cve-vulns/blob/main/tenda_i22/fromsystoolreboot/fromsystoolreboot.md"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45668/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2022-45668"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1878"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45668"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2022-45668"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1878"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45668"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45668"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1878"
          },
          {
            "date": "2022-12-02T18:15:12.313000",
            "db": "NVD",
            "id": "CVE-2022-45668"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45668"
          },
          {
            "date": "2022-12-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1878"
          },
          {
            "date": "2025-04-24T16:15:22.627000",
            "db": "NVD",
            "id": "CVE-2022-45668"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1878"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 Cross-site request forgery vulnerability",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1878"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "cross-site request forgery",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1878"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0073

    Vulnerability from variot - Updated: 2025-04-25 01:41

    Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the ping1 parameter in the formSetAutoPing function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0073",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13085"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45670"
          }
        ]
      },
      "cve": "CVE-2022-45670",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-13085",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45670",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45670",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45670",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-13085",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-1875",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13085"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1875"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45670"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45670"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the ping1 parameter in the formSetAutoPing function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45670"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13085"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45670"
          }
        ],
        "trust": 1.53
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45670",
            "trust": 2.3
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13085",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1875",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45670",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13085"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45670"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1875"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45670"
          }
        ]
      },
      "id": "VAR-202212-0073",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13085"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13085"
          }
        ]
      },
      "last_update_date": "2025-04-25T01:41:45.818000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45670"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/confusedchensir/vulnerabilityprojectrecords/blob/main/formsetautoping_ping1/formsetautoping_ping1.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45670"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45670/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13085"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45670"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1875"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45670"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13085"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45670"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1875"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45670"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13085"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45670"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1875"
          },
          {
            "date": "2022-12-02T18:15:12.437000",
            "db": "NVD",
            "id": "CVE-2022-45670"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13085"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45670"
          },
          {
            "date": "2022-12-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1875"
          },
          {
            "date": "2025-04-24T16:15:23.017000",
            "db": "NVD",
            "id": "CVE-2022-45670"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1875"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 formSetAutoPing function buffer overflow vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13085"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1875"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0072

    Vulnerability from variot - Updated: 2025-04-25 01:39

    Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the index parameter in the formWifiMacFilterSet function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0072",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13083"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45663"
          }
        ]
      },
      "cve": "CVE-2022-45663",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-13083",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45663",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45663",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45663",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-13083",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-1880",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13083"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1880"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45663"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45663"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the index parameter in the formWifiMacFilterSet function. Tenda i22 is a wireless access point of Chinese company Tenda. An attacker could exploit this vulnerability to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45663"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13083"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45663"
          }
        ],
        "trust": 1.53
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45663",
            "trust": 2.3
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-13083",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1880",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45663",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13083"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45663"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1880"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45663"
          }
        ]
      },
      "id": "VAR-202212-0072",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13083"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13083"
          }
        ]
      },
      "last_update_date": "2025-04-25T01:39:37.818000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45663"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/double-q1015/cve-vulns/blob/main/tenda_i22/formwifimacfilterset/formwifimacfilterset.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45663"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45663/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13083"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45663"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1880"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45663"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13083"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45663"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1880"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45663"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13083"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45663"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1880"
          },
          {
            "date": "2022-12-02T18:15:12.080000",
            "db": "NVD",
            "id": "CVE-2022-45663"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-03-01T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-13083"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45663"
          },
          {
            "date": "2022-12-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1880"
          },
          {
            "date": "2025-04-24T16:15:22.227000",
            "db": "NVD",
            "id": "CVE-2022-45663"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1880"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 formWifiMacFilterSet function buffer overflow vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-13083"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1880"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-0075

    Vulnerability from variot - Updated: 2025-04-23 23:01

    Tenda i22 V1.0.0.3(4687) is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolRestoreSet

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0075",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45667"
          }
        ]
      },
      "cve": "CVE-2022-45667",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2022-45667",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45667",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45667",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-1879",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1879"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45667"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45667"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 V1.0.0.3(4687) is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolRestoreSet",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45667"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45667"
          }
        ],
        "trust": 0.99
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45667",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1879",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-45667",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2022-45667"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1879"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45667"
          }
        ]
      },
      "id": "VAR-202212-0075",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.56363636
      },
      "last_update_date": "2025-04-23T23:01:23.085000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-352",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45667"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://github.com/double-q1015/cve-vulns/blob/main/tenda_i22/fromsystoolrestoreset/fromsystoolrestoreset.md"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45667/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2022-45667"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1879"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45667"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2022-45667"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1879"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45667"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45667"
          },
          {
            "date": "2022-12-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1879"
          },
          {
            "date": "2022-12-02T18:15:12.210000",
            "db": "NVD",
            "id": "CVE-2022-45667"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-12-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-45667"
          },
          {
            "date": "2022-12-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-1879"
          },
          {
            "date": "2025-04-23T15:15:58.397000",
            "db": "NVD",
            "id": "CVE-2022-45667"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1879"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 Cross-site request forgery vulnerability",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1879"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "cross-site request forgery",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-1879"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-1735

    Vulnerability from variot - Updated: 2025-04-18 03:44

    Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the list parameter in the formwrlSSIDset function. Shenzhen Tenda Technology Co.,Ltd. of i22 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1735",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "i22  firmware  1.0.0.3(4687)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023874"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45666"
          }
        ]
      },
      "cve": "CVE-2022-45666",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45666",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45666",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45666",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45666",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45666",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-3622",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023874"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3622"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45666"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45666"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the list parameter in the formwrlSSIDset function. Shenzhen Tenda Technology Co.,Ltd. of i22 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45666"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023874"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45666",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023874",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3622",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023874"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3622"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45666"
          }
        ]
      },
      "id": "VAR-202212-1735",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.56363636
      },
      "last_update_date": "2025-04-18T03:44:31.706000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023874"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45666"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/double-q1015/cve-vulns/blob/main/tenda_i22/formwrlssidset/formwrlssidset.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45666"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45666/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023874"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3622"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45666"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023874"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3622"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45666"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-023874"
          },
          {
            "date": "2022-12-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-3622"
          },
          {
            "date": "2022-12-20T15:15:11.890000",
            "db": "NVD",
            "id": "CVE-2022-45666"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-11-30T04:32:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-023874"
          },
          {
            "date": "2022-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-3622"
          },
          {
            "date": "2025-04-17T14:15:21.927000",
            "db": "NVD",
            "id": "CVE-2022-45666"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3622"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i22\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023874"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3622"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202212-1756

    Vulnerability from variot - Updated: 2025-04-18 03:44

    Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the funcpara1 parameter in the formSetCfm function. Shenzhen Tenda Technology Co.,Ltd. of i22 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. A remote attacker can use this vulnerability to submit a special request, execute arbitrary code in the system context or crash the application

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1756",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "i22  firmware  1.0.0.3(4687)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-00010"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023873"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45665"
          }
        ]
      },
      "cve": "CVE-2022-45665",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2023-00010",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-45665",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2022-45665",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-45665",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2022-45665",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-45665",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2023-00010",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202212-3621",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-00010"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023873"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3621"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45665"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45665"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the funcpara1 parameter in the formSetCfm function. Shenzhen Tenda Technology Co.,Ltd. of i22 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. A remote attacker can use this vulnerability to submit a special request, execute arbitrary code in the system context or crash the application",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-45665"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023873"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-00010"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-45665",
            "trust": 3.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023873",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2023-00010",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3621",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-00010"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023873"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3621"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45665"
          }
        ]
      },
      "id": "VAR-202212-1756",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-00010"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-00010"
          }
        ]
      },
      "last_update_date": "2025-04-18T03:44:31.679000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023873"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45665"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.0,
            "url": "https://github.com/double-q1015/cve-vulns/blob/main/tenda_i22/formsetcfm/formwifimacfilterset.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45665"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-45665/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-00010"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023873"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3621"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45665"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2023-00010"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023873"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3621"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-45665"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-12-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-00010"
          },
          {
            "date": "2023-11-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-023873"
          },
          {
            "date": "2022-12-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-3621"
          },
          {
            "date": "2022-12-20T15:15:11.837000",
            "db": "NVD",
            "id": "CVE-2022-45665"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-01-03T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2023-00010"
          },
          {
            "date": "2023-11-30T04:32:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-023873"
          },
          {
            "date": "2022-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202212-3621"
          },
          {
            "date": "2025-04-17T14:15:21.747000",
            "db": "NVD",
            "id": "CVE-2022-45665"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3621"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i22\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-023873"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202212-3621"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202404-2093

    Vulnerability from variot - Updated: 2025-01-29 23:24

    A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i22 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are provided at present

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2093",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "i22  firmware  1.0.0.3(4687)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23301"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017563"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4252"
          }
        ]
      },
      "cve": "CVE-2024-4252",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-4252",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017563",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2024-23301",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-4252",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017563",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-4252",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-4252",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017563",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-23301",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23301"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017563"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4252"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4252"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i22 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are provided at present",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-4252"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017563"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-23301"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-4252",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "262143",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017563",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-23301",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23301"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017563"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4252"
          }
        ]
      },
      "id": "VAR-202404-2093",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23301"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23301"
          }
        ]
      },
      "last_update_date": "2025-01-29T23:24:09.088000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017563"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4252"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.262143"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.319840"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4252"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i22/formseturlfilterrule.md"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.262143"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23301"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017563"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4252"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-23301"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017563"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-4252"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-05-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-23301"
          },
          {
            "date": "2025-01-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017563"
          },
          {
            "date": "2024-04-27T14:15:07.067000",
            "db": "NVD",
            "id": "CVE-2024-4252"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-05-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-23301"
          },
          {
            "date": "2025-01-28T02:40:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017563"
          },
          {
            "date": "2025-01-27T18:27:19.633000",
            "db": "NVD",
            "id": "CVE-2024-4252"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i22\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017563"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202411-0258

    Vulnerability from variot - Updated: 2024-11-15 23:00

    A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as problematic. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV?fgHPOST/goform/SysToo. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of i22 The firmware has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state.

    Tenda i22 has a code problem vulnerability, which is caused by improper handling of the parameter Content-Length, resulting in a null pointer dereference. An attacker can exploit this vulnerability to upload arbitrary files

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202411-0258",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "i22  firmware  1.0.0.3(4687)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-44859"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-012252"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-10750"
          }
        ]
      },
      "cve": "CVE-2024-10750",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-10750",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 6.8,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-012252",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2024-44859",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-10750",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-012252",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-10750",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-10750",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-012252",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-44859",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-44859"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-012252"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-10750"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-10750"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as problematic. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV?fgHPOST/goform/SysToo. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of i22 The firmware has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state. \n\nTenda i22 has a code problem vulnerability, which is caused by improper handling of the parameter Content-Length, resulting in a null pointer dereference. An attacker can exploit this vulnerability to upload arbitrary files",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-10750"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-012252"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-44859"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-10750",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "282919",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-012252",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-44859",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-44859"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-012252"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-10750"
          }
        ]
      },
      "id": "VAR-202411-0258",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-44859"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-44859"
          }
        ]
      },
      "last_update_date": "2024-11-15T23:00:26.614000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-476",
            "trust": 1.0
          },
          {
            "problemtype": "NULL Pointer dereference (CWE-476) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-012252"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-10750"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/xiaobor123/tenda-vul-i22"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.282919"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.435407"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-10750"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.282919"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-44859"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-012252"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-10750"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-44859"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-012252"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-10750"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-11-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-44859"
          },
          {
            "date": "2024-11-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-012252"
          },
          {
            "date": "2024-11-04T02:15:14.667000",
            "db": "NVD",
            "id": "CVE-2024-10750"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-11-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-44859"
          },
          {
            "date": "2024-11-08T03:14:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-012252"
          },
          {
            "date": "2024-11-07T17:09:50.387000",
            "db": "NVD",
            "id": "CVE-2024-10750"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i22\u00a0 in the firmware \u00a0NULL\u00a0 Pointer dereference vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-012252"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202408-0169

    Vulnerability from variot - Updated: 2024-09-13 23:44

    A vulnerability, which was classified as critical, was found in Tenda i22 1.0.0.3(4687). Affected is the function formApPortalPhoneAuth of the file /goform/apPortalPhoneAuth. The manipulation of the argument data leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i22 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda i22 is a dual-band ceiling-mounted wireless access point from Tenda. A remote attacker can use this vulnerability to submit special requests, which can cause the application to crash or execute arbitrary code in the context of the application

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202408-0169",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "i22  firmware  1.0.0.3(4687)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35556"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007835"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7584"
          }
        ]
      },
      "cve": "CVE-2024-7584",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-7584",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-007835",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2024-35556",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-7584",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-7584",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-007835",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-7584",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-7584",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-007835",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-35556",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35556"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007835"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7584"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7584"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability, which was classified as critical, was found in Tenda i22 1.0.0.3(4687). Affected is the function formApPortalPhoneAuth of the file /goform/apPortalPhoneAuth. The manipulation of the argument data leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i22 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda i22 is a dual-band ceiling-mounted wireless access point from Tenda. A remote attacker can use this vulnerability to submit special requests, which can cause the application to crash or execute arbitrary code in the context of the application",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-7584"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007835"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-35556"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-7584",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "273864",
            "trust": 1.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007835",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-35556",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35556"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007835"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7584"
          }
        ]
      },
      "id": "VAR-202408-0169",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35556"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35556"
          }
        ]
      },
      "last_update_date": "2024-09-13T23:44:57.007000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007835"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7584"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/beacox/iot_vuln/tree/main/tenda/i22/apportalphoneauth"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.382836"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.273864"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?id.273864"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-7584"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35556"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007835"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7584"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35556"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007835"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7584"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-08-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-35556"
          },
          {
            "date": "2024-09-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-007835"
          },
          {
            "date": "2024-08-07T17:15:52.730000",
            "db": "NVD",
            "id": "CVE-2024-7584"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-08-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-35556"
          },
          {
            "date": "2024-09-12T01:39:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-007835"
          },
          {
            "date": "2024-09-11T19:25:04.143000",
            "db": "NVD",
            "id": "CVE-2024-7584"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i22\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007835"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202408-0245

    Vulnerability from variot - Updated: 2024-09-13 23:32

    A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as critical. Affected by this vulnerability is the function formApPortalWebAuth of the file /goform/apPortalAuth. The manipulation of the argument webUserName/webUserPassword leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i22 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda i22 is a dual-band ceiling-mounted wireless access point from Tenda. A remote attacker can use this vulnerability to submit special requests, which can cause the application to crash or execute arbitrary code in the context of the application

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202408-0245",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "i22",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "1.0.0.3\\(4687\\)"
          },
          {
            "model": "i22",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "i22  firmware  1.0.0.3(4687)"
          },
          {
            "model": "i22",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0.0.3(4687)"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35555"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007907"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7585"
          }
        ]
      },
      "cve": "CVE-2024-7585",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-7585",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-007907",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2024-35555",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-7585",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-7585",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-007907",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-7585",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-7585",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-007907",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2024-35555",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35555"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007907"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7585"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7585"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as critical. Affected by this vulnerability is the function formApPortalWebAuth of the file /goform/apPortalAuth. The manipulation of the argument webUserName/webUserPassword leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of i22 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda i22 is a dual-band ceiling-mounted wireless access point from Tenda. A remote attacker can use this vulnerability to submit special requests, which can cause the application to crash or execute arbitrary code in the context of the application",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-7585"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007907"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-35555"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-7585",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "273865",
            "trust": 1.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007907",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2024-35555",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35555"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007907"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7585"
          }
        ]
      },
      "id": "VAR-202408-0245",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35555"
          }
        ],
        "trust": 1.16363636
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35555"
          }
        ]
      },
      "last_update_date": "2024-09-13T23:32:48.919000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007907"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7585"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/beacox/iot_vuln/tree/main/tenda/i22/apportalwebauth"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.382837"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.273865"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?id.273865"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-7585"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35555"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007907"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7585"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2024-35555"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007907"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-7585"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-08-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-35555"
          },
          {
            "date": "2024-09-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-007907"
          },
          {
            "date": "2024-08-07T17:15:53.017000",
            "db": "NVD",
            "id": "CVE-2024-7585"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2024-08-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2024-35555"
          },
          {
            "date": "2024-09-12T05:56:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-007907"
          },
          {
            "date": "2024-09-11T19:32:34.007000",
            "db": "NVD",
            "id": "CVE-2024-7585"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0i22\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-007907"
          }
        ],
        "trust": 0.8
      }
    }

    CVE-2025-9297 (GCVE-0-2025-9297)

    Vulnerability from nvd – Published: 2025-08-21 12:02 – Updated: 2025-08-21 13:24
    VLAI
    Title
    Tenda i22 wxportalauth formWeixinAuthInfoGet stack-based overflow
    Summary
    A vulnerability was detected in Tenda i22 1.0.0.3(4687). This impacts the function formWeixinAuthInfoGet of the file /goform/wxportalauth. Performing manipulation of the argument Type results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-21 13:24 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9297",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-21T13:24:48.732809Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-21T13:24:53.066Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/davybat/IoT-Vuls/blob/main/tenda/formWeixinAuthInfoGet.md#poc"
              },
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/davybat/IoT-Vuls/blob/main/tenda/formWeixinAuthInfoGet.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "davybat (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda i22 1.0.0.3(4687). This impacts the function formWeixinAuthInfoGet of the file /goform/wxportalauth. Performing manipulation of the argument Type results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used."
            },
            {
              "lang": "de",
              "value": "In Tenda i22 1.0.0.3(4687) wurde eine Schwachstelle gefunden. Es ist betroffen die Funktion formWeixinAuthInfoGet der Datei /goform/wxportalauth. Durch Manipulieren des Arguments Type mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Es ist m\u00f6glich, den Angriff aus der Ferne durchzuf\u00fchren. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-21T12:02:11.484Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-320902 | Tenda i22 wxportalauth formWeixinAuthInfoGet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.320902"
            },
            {
              "name": "VDB-320902 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.320902"
            },
            {
              "name": "Submit #632332 | Tenda i22 v1.0.0.3(4687) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.632332"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/davybat/IoT-Vuls/blob/main/tenda/formWeixinAuthInfoGet.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/davybat/IoT-Vuls/blob/main/tenda/formWeixinAuthInfoGet.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-08-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-08-21T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-08-21T07:25:20.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 wxportalauth formWeixinAuthInfoGet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-9297",
        "datePublished": "2025-08-21T12:02:11.484Z",
        "dateReserved": "2025-08-21T05:20:16.875Z",
        "dateUpdated": "2025-08-21T13:24:53.066Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-10750 (GCVE-0-2024-10750)

    Vulnerability from nvd – Published: 2024-11-04 01:00 – Updated: 2024-11-05 14:55
    VLAI
    Title
    Tenda i22 SysToo websReadEvent null pointer dereference
    Summary
    A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as problematic. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV?fgHPOST/goform/SysToo. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-05 14:54 UTC
    CWE
    • CWE-476 - NULL Pointer Dereference
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.282919 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.282919 signaturepermissions-required
    https://vuldb.com/?submit.435407 third-party-advisory
    https://github.com/xiaobor123/tenda-vul-i22 exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    tenda i22 Affected: 1.0.0.3(4687)
        cpe:2.3:h:tenda:i22:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:i22:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "i22",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.3(4687)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-10750",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-05T14:54:25.326328Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-05T14:55:33.301Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "xiaobor123 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as problematic. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV?fgHPOST/goform/SysToo. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "In Tenda i22 1.0.0.3(4687) wurde eine Schwachstelle gefunden. Sie wurde als problematisch eingestuft. Hierbei betrifft es die Funktion websReadEvent der Datei /goform/GetIPTV?fgHPOST/goform/SysToo. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.8,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "NULL Pointer Dereference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-04T01:00:07.611Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-282919 | Tenda i22 SysToo websReadEvent null pointer dereference",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.282919"
            },
            {
              "name": "VDB-282919 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.282919"
            },
            {
              "name": "Submit #435407 | Tenda i22 V1.0.0.3(4687) NULL Pointer Dereference",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.435407"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xiaobor123/tenda-vul-i22"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-11-03T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-11-03T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-11-03T07:40:20.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 SysToo websReadEvent null pointer dereference"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-10750",
        "datePublished": "2024-11-04T01:00:07.611Z",
        "dateReserved": "2024-11-03T06:35:17.315Z",
        "dateUpdated": "2024-11-05T14:55:33.301Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7585 (GCVE-0-2024-7585)

    Vulnerability from nvd – Published: 2024-08-07 17:00 – Updated: 2024-08-07 18:12
    VLAI
    Title
    Tenda i22 apPortalAuth formApPortalWebAuth buffer overflow
    Summary
    A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as critical. Affected by this vulnerability is the function formApPortalWebAuth of the file /goform/apPortalAuth. The manipulation of the argument webUserName/webUserPassword leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-07 17:55 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273865 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273865 signaturepermissions-required
    https://vuldb.com/?submit.382837 third-party-advisory
    https://github.com/BeaCox/IoT_vuln/tree/main/tend… exploit
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    tenda i22_firmware Affected: 1.0.0.3\(4687\)
        cpe:2.3:o:tenda:i22_firmware:1.0.0.3\(4687\):*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\(4687\\):*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "i22_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.3\\(4687\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7585",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T17:55:23.079420Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T18:12:56.690Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "BeaCox (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as critical. Affected by this vulnerability is the function formApPortalWebAuth of the file /goform/apPortalAuth. The manipulation of the argument webUserName/webUserPassword leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda i22 1.0.0.3(4687) wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um die Funktion formApPortalWebAuth der Datei /goform/apPortalAuth. Durch das Beeinflussen des Arguments webUserName/webUserPassword mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-07T17:00:06.990Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273865 | Tenda i22 apPortalAuth formApPortalWebAuth buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273865"
            },
            {
              "name": "VDB-273865 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273865"
            },
            {
              "name": "Submit #382837 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.382837"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/i22/ApPortalWebAuth"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-07T08:58:05.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 apPortalAuth formApPortalWebAuth buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7585",
        "datePublished": "2024-08-07T17:00:06.990Z",
        "dateReserved": "2024-08-07T06:52:52.240Z",
        "dateUpdated": "2024-08-07T18:12:56.690Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7584 (GCVE-0-2024-7584)

    Vulnerability from nvd – Published: 2024-08-07 16:31 – Updated: 2024-08-07 17:47
    VLAI
    Title
    Tenda i22 apPortalPhoneAuth formApPortalPhoneAuth buffer overflow
    Summary
    A vulnerability, which was classified as critical, was found in Tenda i22 1.0.0.3(4687). Affected is the function formApPortalPhoneAuth of the file /goform/apPortalPhoneAuth. The manipulation of the argument data leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-07 17:46 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273864 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273864 signaturepermissions-required
    https://vuldb.com/?submit.382836 third-party-advisory
    https://github.com/BeaCox/IoT_vuln/tree/main/tend… exploit
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    tenda i22_firmware Affected: 1.0.0.3\(4687\)
        cpe:2.3:o:tenda:i22_firmware:1.0.0.3\(4687\):*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\(4687\\):*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "i22_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.3\\(4687\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7584",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T17:46:34.703315Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T17:47:32.819Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "BeaCox (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, was found in Tenda i22 1.0.0.3(4687). Affected is the function formApPortalPhoneAuth of the file /goform/apPortalPhoneAuth. The manipulation of the argument data leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine Schwachstelle in Tenda i22 1.0.0.3(4687) gefunden. Sie wurde als kritisch eingestuft. Betroffen hiervon ist die Funktion formApPortalPhoneAuth der Datei /goform/apPortalPhoneAuth. Durch Manipulieren des Arguments data mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-07T16:31:04.683Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273864 | Tenda i22 apPortalPhoneAuth formApPortalPhoneAuth buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273864"
            },
            {
              "name": "VDB-273864 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273864"
            },
            {
              "name": "Submit #382836 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.382836"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/i22/ApPortalPhoneAuth"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-07T08:58:04.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 apPortalPhoneAuth formApPortalPhoneAuth buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7584",
        "datePublished": "2024-08-07T16:31:04.683Z",
        "dateReserved": "2024-08-07T06:52:49.391Z",
        "dateUpdated": "2024-08-07T17:47:32.819Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7583 (GCVE-0-2024-7583)

    Vulnerability from nvd – Published: 2024-08-07 16:00 – Updated: 2024-08-07 17:37
    VLAI
    Title
    Tenda i22 apPortalOneKeyAuth formApPortalOneKeyAuth buffer overflow
    Summary
    A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-07 17:30 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273863 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273863 signaturepermissions-required
    https://vuldb.com/?submit.382835 third-party-advisory
    https://github.com/BeaCox/IoT_vuln/tree/main/tend… exploit
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    tenda i22_firmware Affected: 1.0.0.3\(4687\)
        cpe:2.3:o:tenda:i22_firmware:1.0.0.3\(4687\):*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\(4687\\):*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "i22_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.3\\(4687\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7583",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T17:30:49.966839Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T17:37:33.704Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "BeaCox (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda i22 1.0.0.3(4687) entdeckt. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion formApPortalOneKeyAuth der Datei /goform/apPortalOneKeyAuth. Durch das Manipulieren des Arguments data mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-07T16:00:08.539Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273863 | Tenda i22 apPortalOneKeyAuth formApPortalOneKeyAuth buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273863"
            },
            {
              "name": "VDB-273863 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273863"
            },
            {
              "name": "Submit #382835 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.382835"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/i22/ApPortalOneKeyAuth"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-07T08:58:02.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 apPortalOneKeyAuth formApPortalOneKeyAuth buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7583",
        "datePublished": "2024-08-07T16:00:08.539Z",
        "dateReserved": "2024-08-07T06:52:46.224Z",
        "dateUpdated": "2024-08-07T17:37:33.704Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7582 (GCVE-0-2024-7582)

    Vulnerability from nvd – Published: 2024-08-07 15:31 – Updated: 2024-08-07 17:41
    VLAI
    Title
    Tenda i22 apPortalAccessCodeAuth formApPortalAccessCodeAuth buffer overflow
    Summary
    A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-07 17:40 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273862 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273862 signaturepermissions-required
    https://vuldb.com/?submit.382834 third-party-advisory
    https://github.com/BeaCox/IoT_vuln/tree/main/tend… exploit
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    tenda i22_firmware Affected: 1.0.0.3\(4687\)
        cpe:2.3:o:tenda:i22_firmware:1.0.0.3\(4687\):*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\(4687\\):*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "i22_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.3\\(4687\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7582",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T17:40:51.207826Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T17:41:35.463Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "BeaCox (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda i22 1.0.0.3(4687) wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion formApPortalAccessCodeAuth der Datei /goform/apPortalAccessCodeAuth. Mittels Manipulieren des Arguments accessCode/data/acceInfo mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-07T15:31:04.959Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273862 | Tenda i22 apPortalAccessCodeAuth formApPortalAccessCodeAuth buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273862"
            },
            {
              "name": "VDB-273862 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273862"
            },
            {
              "name": "Submit #382834 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.382834"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/i22/ApPortalAccessCodeAuth"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-07T08:58:01.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 apPortalAccessCodeAuth formApPortalAccessCodeAuth buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7582",
        "datePublished": "2024-08-07T15:31:04.959Z",
        "dateReserved": "2024-08-07T06:52:43.476Z",
        "dateUpdated": "2024-08-07T17:41:35.463Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-4252 (GCVE-0-2024-4252)

    Vulnerability from nvd – Published: 2024-04-27 13:31 – Updated: 2024-08-01 20:33
    VLAI
    Title
    Tenda i22 formSetUrlFilterRule stack-based overflow
    Summary
    A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-04-30 19:51 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.262143 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.262143 signaturepermissions-required
    https://vuldb.com/?submit.319840 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… related
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    tenda i22_firmware Affected: 1.0.0.3\(4687\)
        cpe:2.3:o:tenda:i22_firmware:1.0.0.3\(4687\):*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\(4687\\):*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "i22_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.3\\(4687\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-4252",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-30T19:51:45.729808Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-23T17:43:07.157Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:33:53.167Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-262143 | Tenda i22 formSetUrlFilterRule stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.262143"
              },
              {
                "name": "VDB-262143 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.262143"
              },
              {
                "name": "Submit #319840 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.319840"
              },
              {
                "tags": [
                  "related",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_tu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine Schwachstelle in Tenda i22 1.0.0.3(4687) entdeckt. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion formSetUrlFilterRule. Mit der Manipulation des Arguments groupIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-27T13:31:04.906Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-262143 | Tenda i22 formSetUrlFilterRule stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.262143"
            },
            {
              "name": "VDB-262143 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.262143"
            },
            {
              "name": "Submit #319840 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.319840"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i22/formSetUrlFilterRule.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-04-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-04-26T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-04-26T14:46:27.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 formSetUrlFilterRule stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-4252",
        "datePublished": "2024-04-27T13:31:04.906Z",
        "dateReserved": "2024-04-26T12:40:45.945Z",
        "dateUpdated": "2024-08-01T20:33:53.167Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-9297 (GCVE-0-2025-9297)

    Vulnerability from cvelistv5 – Published: 2025-08-21 12:02 – Updated: 2025-08-21 13:24
    VLAI
    Title
    Tenda i22 wxportalauth formWeixinAuthInfoGet stack-based overflow
    Summary
    A vulnerability was detected in Tenda i22 1.0.0.3(4687). This impacts the function formWeixinAuthInfoGet of the file /goform/wxportalauth. Performing manipulation of the argument Type results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-21 13:24 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9297",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-21T13:24:48.732809Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-21T13:24:53.066Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/davybat/IoT-Vuls/blob/main/tenda/formWeixinAuthInfoGet.md#poc"
              },
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/davybat/IoT-Vuls/blob/main/tenda/formWeixinAuthInfoGet.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "davybat (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda i22 1.0.0.3(4687). This impacts the function formWeixinAuthInfoGet of the file /goform/wxportalauth. Performing manipulation of the argument Type results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used."
            },
            {
              "lang": "de",
              "value": "In Tenda i22 1.0.0.3(4687) wurde eine Schwachstelle gefunden. Es ist betroffen die Funktion formWeixinAuthInfoGet der Datei /goform/wxportalauth. Durch Manipulieren des Arguments Type mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Es ist m\u00f6glich, den Angriff aus der Ferne durchzuf\u00fchren. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-21T12:02:11.484Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-320902 | Tenda i22 wxportalauth formWeixinAuthInfoGet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.320902"
            },
            {
              "name": "VDB-320902 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.320902"
            },
            {
              "name": "Submit #632332 | Tenda i22 v1.0.0.3(4687) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.632332"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/davybat/IoT-Vuls/blob/main/tenda/formWeixinAuthInfoGet.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/davybat/IoT-Vuls/blob/main/tenda/formWeixinAuthInfoGet.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-08-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-08-21T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-08-21T07:25:20.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 wxportalauth formWeixinAuthInfoGet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-9297",
        "datePublished": "2025-08-21T12:02:11.484Z",
        "dateReserved": "2025-08-21T05:20:16.875Z",
        "dateUpdated": "2025-08-21T13:24:53.066Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-10750 (GCVE-0-2024-10750)

    Vulnerability from cvelistv5 – Published: 2024-11-04 01:00 – Updated: 2024-11-05 14:55
    VLAI
    Title
    Tenda i22 SysToo websReadEvent null pointer dereference
    Summary
    A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as problematic. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV?fgHPOST/goform/SysToo. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-05 14:54 UTC
    CWE
    • CWE-476 - NULL Pointer Dereference
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.282919 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.282919 signaturepermissions-required
    https://vuldb.com/?submit.435407 third-party-advisory
    https://github.com/xiaobor123/tenda-vul-i22 exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    tenda i22 Affected: 1.0.0.3(4687)
        cpe:2.3:h:tenda:i22:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:i22:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "i22",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.3(4687)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-10750",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-05T14:54:25.326328Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-05T14:55:33.301Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "xiaobor123 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as problematic. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV?fgHPOST/goform/SysToo. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "In Tenda i22 1.0.0.3(4687) wurde eine Schwachstelle gefunden. Sie wurde als problematisch eingestuft. Hierbei betrifft es die Funktion websReadEvent der Datei /goform/GetIPTV?fgHPOST/goform/SysToo. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.8,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "NULL Pointer Dereference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-04T01:00:07.611Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-282919 | Tenda i22 SysToo websReadEvent null pointer dereference",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.282919"
            },
            {
              "name": "VDB-282919 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.282919"
            },
            {
              "name": "Submit #435407 | Tenda i22 V1.0.0.3(4687) NULL Pointer Dereference",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.435407"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xiaobor123/tenda-vul-i22"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-11-03T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-11-03T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-11-03T07:40:20.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 SysToo websReadEvent null pointer dereference"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-10750",
        "datePublished": "2024-11-04T01:00:07.611Z",
        "dateReserved": "2024-11-03T06:35:17.315Z",
        "dateUpdated": "2024-11-05T14:55:33.301Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7585 (GCVE-0-2024-7585)

    Vulnerability from cvelistv5 – Published: 2024-08-07 17:00 – Updated: 2024-08-07 18:12
    VLAI
    Title
    Tenda i22 apPortalAuth formApPortalWebAuth buffer overflow
    Summary
    A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as critical. Affected by this vulnerability is the function formApPortalWebAuth of the file /goform/apPortalAuth. The manipulation of the argument webUserName/webUserPassword leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-07 17:55 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273865 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273865 signaturepermissions-required
    https://vuldb.com/?submit.382837 third-party-advisory
    https://github.com/BeaCox/IoT_vuln/tree/main/tend… exploit
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    tenda i22_firmware Affected: 1.0.0.3\(4687\)
        cpe:2.3:o:tenda:i22_firmware:1.0.0.3\(4687\):*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\(4687\\):*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "i22_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.3\\(4687\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7585",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T17:55:23.079420Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T18:12:56.690Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "BeaCox (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as critical. Affected by this vulnerability is the function formApPortalWebAuth of the file /goform/apPortalAuth. The manipulation of the argument webUserName/webUserPassword leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda i22 1.0.0.3(4687) wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um die Funktion formApPortalWebAuth der Datei /goform/apPortalAuth. Durch das Beeinflussen des Arguments webUserName/webUserPassword mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-07T17:00:06.990Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273865 | Tenda i22 apPortalAuth formApPortalWebAuth buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273865"
            },
            {
              "name": "VDB-273865 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273865"
            },
            {
              "name": "Submit #382837 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.382837"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/i22/ApPortalWebAuth"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-07T08:58:05.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 apPortalAuth formApPortalWebAuth buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7585",
        "datePublished": "2024-08-07T17:00:06.990Z",
        "dateReserved": "2024-08-07T06:52:52.240Z",
        "dateUpdated": "2024-08-07T18:12:56.690Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7584 (GCVE-0-2024-7584)

    Vulnerability from cvelistv5 – Published: 2024-08-07 16:31 – Updated: 2024-08-07 17:47
    VLAI
    Title
    Tenda i22 apPortalPhoneAuth formApPortalPhoneAuth buffer overflow
    Summary
    A vulnerability, which was classified as critical, was found in Tenda i22 1.0.0.3(4687). Affected is the function formApPortalPhoneAuth of the file /goform/apPortalPhoneAuth. The manipulation of the argument data leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-07 17:46 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273864 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273864 signaturepermissions-required
    https://vuldb.com/?submit.382836 third-party-advisory
    https://github.com/BeaCox/IoT_vuln/tree/main/tend… exploit
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    tenda i22_firmware Affected: 1.0.0.3\(4687\)
        cpe:2.3:o:tenda:i22_firmware:1.0.0.3\(4687\):*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\(4687\\):*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "i22_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.3\\(4687\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7584",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T17:46:34.703315Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T17:47:32.819Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "BeaCox (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, was found in Tenda i22 1.0.0.3(4687). Affected is the function formApPortalPhoneAuth of the file /goform/apPortalPhoneAuth. The manipulation of the argument data leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine Schwachstelle in Tenda i22 1.0.0.3(4687) gefunden. Sie wurde als kritisch eingestuft. Betroffen hiervon ist die Funktion formApPortalPhoneAuth der Datei /goform/apPortalPhoneAuth. Durch Manipulieren des Arguments data mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-07T16:31:04.683Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273864 | Tenda i22 apPortalPhoneAuth formApPortalPhoneAuth buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273864"
            },
            {
              "name": "VDB-273864 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273864"
            },
            {
              "name": "Submit #382836 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.382836"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/i22/ApPortalPhoneAuth"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-07T08:58:04.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 apPortalPhoneAuth formApPortalPhoneAuth buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7584",
        "datePublished": "2024-08-07T16:31:04.683Z",
        "dateReserved": "2024-08-07T06:52:49.391Z",
        "dateUpdated": "2024-08-07T17:47:32.819Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7583 (GCVE-0-2024-7583)

    Vulnerability from cvelistv5 – Published: 2024-08-07 16:00 – Updated: 2024-08-07 17:37
    VLAI
    Title
    Tenda i22 apPortalOneKeyAuth formApPortalOneKeyAuth buffer overflow
    Summary
    A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-07 17:30 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273863 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273863 signaturepermissions-required
    https://vuldb.com/?submit.382835 third-party-advisory
    https://github.com/BeaCox/IoT_vuln/tree/main/tend… exploit
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    tenda i22_firmware Affected: 1.0.0.3\(4687\)
        cpe:2.3:o:tenda:i22_firmware:1.0.0.3\(4687\):*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\(4687\\):*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "i22_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.3\\(4687\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7583",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T17:30:49.966839Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T17:37:33.704Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "BeaCox (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda i22 1.0.0.3(4687) entdeckt. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion formApPortalOneKeyAuth der Datei /goform/apPortalOneKeyAuth. Durch das Manipulieren des Arguments data mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-07T16:00:08.539Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273863 | Tenda i22 apPortalOneKeyAuth formApPortalOneKeyAuth buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273863"
            },
            {
              "name": "VDB-273863 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273863"
            },
            {
              "name": "Submit #382835 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.382835"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/i22/ApPortalOneKeyAuth"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-07T08:58:02.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 apPortalOneKeyAuth formApPortalOneKeyAuth buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7583",
        "datePublished": "2024-08-07T16:00:08.539Z",
        "dateReserved": "2024-08-07T06:52:46.224Z",
        "dateUpdated": "2024-08-07T17:37:33.704Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7582 (GCVE-0-2024-7582)

    Vulnerability from cvelistv5 – Published: 2024-08-07 15:31 – Updated: 2024-08-07 17:41
    VLAI
    Title
    Tenda i22 apPortalAccessCodeAuth formApPortalAccessCodeAuth buffer overflow
    Summary
    A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-07 17:40 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273862 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273862 signaturepermissions-required
    https://vuldb.com/?submit.382834 third-party-advisory
    https://github.com/BeaCox/IoT_vuln/tree/main/tend… exploit
    Impacted products
    Vendor Product Version
    Tenda i22 Affected: 1.0.0.3(4687)
    Create a notification for this product.
    tenda i22_firmware Affected: 1.0.0.3\(4687\)
        cpe:2.3:o:tenda:i22_firmware:1.0.0.3\(4687\):*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:i22_firmware:1.0.0.3\\(4687\\):*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "i22_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.3\\(4687\\)"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7582",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T17:40:51.207826Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T17:41:35.463Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "i22",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.3(4687)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "BeaCox (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda i22 1.0.0.3(4687) wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion formApPortalAccessCodeAuth der Datei /goform/apPortalAccessCodeAuth. Mittels Manipulieren des Arguments accessCode/data/acceInfo mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-07T15:31:04.959Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273862 | Tenda i22 apPortalAccessCodeAuth formApPortalAccessCodeAuth buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273862"
            },
            {
              "name": "VDB-273862 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273862"
            },
            {
              "name": "Submit #382834 | Tenda i22 V1.0.0.3(4687) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.382834"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/i22/ApPortalAccessCodeAuth"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-07T08:58:01.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda i22 apPortalAccessCodeAuth formApPortalAccessCodeAuth buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7582",
        "datePublished": "2024-08-07T15:31:04.959Z",
        "dateReserved": "2024-08-07T06:52:43.476Z",
        "dateUpdated": "2024-08-07T17:41:35.463Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",