Search
Find a vulnerability
Search criteria
10 vulnerabilities found for hit_7300 by infinera
CVE-2024-28807 (GCVE-0-2024-28807)
Vulnerability from nvd – Published: 2024-09-30 00:00 – Updated: 2024-09-30 20:57
VLAI
EPSS
VEX
Summary
An issue was discovered in Infinera hiT 7300 5.60.50. Cleartext storage of sensitive information in the memory of the @CT desktop management application allows guest OS administrators to obtain various users' passwords by accessing memory dumps of the desktop application.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-30 20:56 UTC
CWE
- n/a
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:infinera:hit_7300:5.60.50:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hit_7300",
"vendor": "infinera",
"versions": [
{
"status": "affected",
"version": "5.60.50"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28807",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T20:56:38.555970Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T20:57:45.944Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Infinera hiT 7300 5.60.50. Cleartext storage of sensitive information in the memory of the @CT desktop management application allows guest OS administrators to obtain various users\u0027 passwords by accessing memory dumps of the desktop application."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T20:26:38.173Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28807"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-28807",
"datePublished": "2024-09-30T00:00:00.000Z",
"dateReserved": "2024-03-11T00:00:00.000Z",
"dateUpdated": "2024-09-30T20:57:45.944Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28813 (GCVE-0-2024-28813)
Vulnerability from nvd – Published: 2024-09-30 00:00 – Updated: 2024-09-30 18:46
VLAI
EPSS
VEX
Summary
An issue was discovered in Infinera hiT 7300 5.60.50. Undocumented privileged functions in the @CT management application allow an attacker to activate remote SSH access to the appliance via an unexpected network interface.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-30 18:43 UTC
CWE
- n/a
- CWE-269 - Improper Privilege Management
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:infinera:hit_7300:5.60.50:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hit_7300",
"vendor": "infinera",
"versions": [
{
"status": "affected",
"version": "5.60.50"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28813",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T18:43:01.618919Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:46:32.091Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Infinera hiT 7300 5.60.50. Undocumented privileged functions in the @CT management application allow an attacker to activate remote SSH access to the appliance via an unexpected network interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:23:19.933Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28813"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-28813",
"datePublished": "2024-09-30T00:00:00.000Z",
"dateReserved": "2024-03-11T00:00:00.000Z",
"dateUpdated": "2024-09-30T18:46:32.091Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28812 (GCVE-0-2024-28812)
Vulnerability from nvd – Published: 2024-09-30 00:00 – Updated: 2024-09-30 18:39
VLAI
EPSS
VEX
Summary
An issue was discovered in Infinera hiT 7300 5.60.50. A hidden SSH service (on the local management network interface) with hardcoded credentials allows attackers to access the appliance operating system (with highest privileges) via an SSH connection.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-30 18:39 UTC
CWE
- n/a
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:infinera:hit_7300:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hit_7300",
"vendor": "infinera",
"versions": [
{
"status": "affected",
"version": "5.60.50"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28812",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T18:39:00.558124Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:39:04.620Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Infinera hiT 7300 5.60.50. A hidden SSH service (on the local management network interface) with hardcoded credentials allows attackers to access the appliance operating system (with highest privileges) via an SSH connection."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:17:51.956Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28812"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-28812",
"datePublished": "2024-09-30T00:00:00.000Z",
"dateReserved": "2024-03-11T00:00:00.000Z",
"dateUpdated": "2024-09-30T18:39:04.620Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28810 (GCVE-0-2024-28810)
Vulnerability from nvd – Published: 2024-09-30 00:00 – Updated: 2024-09-30 20:54
VLAI
EPSS
VEX
Summary
An issue was discovered in Infinera hiT 7300 5.60.50. Sensitive information inside diagnostic files (exported by the @CT application) allows an attacker to achieve loss of confidentiality by analyzing these files.
Severity
6.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-30 20:46 UTC
CWE
- n/a
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:infinera:hit_7300:5.60.50:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hit_7300",
"vendor": "infinera",
"versions": [
{
"status": "affected",
"version": "5.60.50"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28810",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T20:46:55.953917Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T20:54:31.555Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Infinera hiT 7300 5.60.50. Sensitive information inside diagnostic files (exported by the @CT application) allows an attacker to achieve loss of confidentiality by analyzing these files."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:20:05.393Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28810"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-28810",
"datePublished": "2024-09-30T00:00:00.000Z",
"dateReserved": "2024-03-11T00:00:00.000Z",
"dateUpdated": "2024-09-30T20:54:31.555Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28809 (GCVE-0-2024-28809)
Vulnerability from nvd – Published: 2024-09-30 00:00 – Updated: 2024-09-30 20:55
VLAI
EPSS
VEX
Summary
An issue was discovered in Infinera hiT 7300 5.60.50. Cleartext storage of sensitive password in firmware update packages allows attackers to access various appliance services via hardcoded credentials.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-30 20:50 UTC
CWE
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:infinera:hit_7300:5.60.50:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hit_7300",
"vendor": "infinera",
"versions": [
{
"status": "affected",
"version": "5.60.50"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28809",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T20:50:50.976160Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T20:55:59.795Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Infinera hiT 7300 5.60.50. Cleartext storage of sensitive password in firmware update packages allows attackers to access various appliance services via hardcoded credentials."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:03:27.052Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28809"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-28809",
"datePublished": "2024-09-30T00:00:00.000Z",
"dateReserved": "2024-03-11T00:00:00.000Z",
"dateUpdated": "2024-09-30T20:55:59.795Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28807 (GCVE-0-2024-28807)
Vulnerability from cvelistv5 – Published: 2024-09-30 00:00 – Updated: 2024-09-30 20:57
VLAI
EPSS
VEX
Summary
An issue was discovered in Infinera hiT 7300 5.60.50. Cleartext storage of sensitive information in the memory of the @CT desktop management application allows guest OS administrators to obtain various users' passwords by accessing memory dumps of the desktop application.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-30 20:56 UTC
CWE
- n/a
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:infinera:hit_7300:5.60.50:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hit_7300",
"vendor": "infinera",
"versions": [
{
"status": "affected",
"version": "5.60.50"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28807",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T20:56:38.555970Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T20:57:45.944Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Infinera hiT 7300 5.60.50. Cleartext storage of sensitive information in the memory of the @CT desktop management application allows guest OS administrators to obtain various users\u0027 passwords by accessing memory dumps of the desktop application."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T20:26:38.173Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28807"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-28807",
"datePublished": "2024-09-30T00:00:00.000Z",
"dateReserved": "2024-03-11T00:00:00.000Z",
"dateUpdated": "2024-09-30T20:57:45.944Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28812 (GCVE-0-2024-28812)
Vulnerability from cvelistv5 – Published: 2024-09-30 00:00 – Updated: 2024-09-30 18:39
VLAI
EPSS
VEX
Summary
An issue was discovered in Infinera hiT 7300 5.60.50. A hidden SSH service (on the local management network interface) with hardcoded credentials allows attackers to access the appliance operating system (with highest privileges) via an SSH connection.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-30 18:39 UTC
CWE
- n/a
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:infinera:hit_7300:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hit_7300",
"vendor": "infinera",
"versions": [
{
"status": "affected",
"version": "5.60.50"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28812",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T18:39:00.558124Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:39:04.620Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Infinera hiT 7300 5.60.50. A hidden SSH service (on the local management network interface) with hardcoded credentials allows attackers to access the appliance operating system (with highest privileges) via an SSH connection."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:17:51.956Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28812"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-28812",
"datePublished": "2024-09-30T00:00:00.000Z",
"dateReserved": "2024-03-11T00:00:00.000Z",
"dateUpdated": "2024-09-30T18:39:04.620Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28809 (GCVE-0-2024-28809)
Vulnerability from cvelistv5 – Published: 2024-09-30 00:00 – Updated: 2024-09-30 20:55
VLAI
EPSS
VEX
Summary
An issue was discovered in Infinera hiT 7300 5.60.50. Cleartext storage of sensitive password in firmware update packages allows attackers to access various appliance services via hardcoded credentials.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-30 20:50 UTC
CWE
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:infinera:hit_7300:5.60.50:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hit_7300",
"vendor": "infinera",
"versions": [
{
"status": "affected",
"version": "5.60.50"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28809",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T20:50:50.976160Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T20:55:59.795Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Infinera hiT 7300 5.60.50. Cleartext storage of sensitive password in firmware update packages allows attackers to access various appliance services via hardcoded credentials."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:03:27.052Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28809"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-28809",
"datePublished": "2024-09-30T00:00:00.000Z",
"dateReserved": "2024-03-11T00:00:00.000Z",
"dateUpdated": "2024-09-30T20:55:59.795Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28810 (GCVE-0-2024-28810)
Vulnerability from cvelistv5 – Published: 2024-09-30 00:00 – Updated: 2024-09-30 20:54
VLAI
EPSS
VEX
Summary
An issue was discovered in Infinera hiT 7300 5.60.50. Sensitive information inside diagnostic files (exported by the @CT application) allows an attacker to achieve loss of confidentiality by analyzing these files.
Severity
6.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-30 20:46 UTC
CWE
- n/a
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:infinera:hit_7300:5.60.50:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hit_7300",
"vendor": "infinera",
"versions": [
{
"status": "affected",
"version": "5.60.50"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28810",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T20:46:55.953917Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T20:54:31.555Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Infinera hiT 7300 5.60.50. Sensitive information inside diagnostic files (exported by the @CT application) allows an attacker to achieve loss of confidentiality by analyzing these files."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:20:05.393Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28810"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-28810",
"datePublished": "2024-09-30T00:00:00.000Z",
"dateReserved": "2024-03-11T00:00:00.000Z",
"dateUpdated": "2024-09-30T20:54:31.555Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-28813 (GCVE-0-2024-28813)
Vulnerability from cvelistv5 – Published: 2024-09-30 00:00 – Updated: 2024-09-30 18:46
VLAI
EPSS
VEX
Summary
An issue was discovered in Infinera hiT 7300 5.60.50. Undocumented privileged functions in the @CT management application allow an attacker to activate remote SSH access to the appliance via an unexpected network interface.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-30 18:43 UTC
CWE
- n/a
- CWE-269 - Improper Privilege Management
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:infinera:hit_7300:5.60.50:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hit_7300",
"vendor": "infinera",
"versions": [
{
"status": "affected",
"version": "5.60.50"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-28813",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-30T18:43:01.618919Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:46:32.091Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Infinera hiT 7300 5.60.50. Undocumented privileged functions in the @CT management application allow an attacker to activate remote SSH access to the appliance via an unexpected network interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T18:23:19.933Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28813"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-28813",
"datePublished": "2024-09-30T00:00:00.000Z",
"dateReserved": "2024-03-11T00:00:00.000Z",
"dateUpdated": "2024-09-30T18:46:32.091Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}