Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
122 vulnerabilities found for fh1202_firmware by tenda
CVE-2026-3811 (GCVE-0-2026-3811)
Vulnerability from nvd – Published: 2026-03-09 08:32 – Updated: 2026-03-09 18:16
VLAI?
Title
Tenda FH1202 P2pListFilter fromP2pListFilter stack-based overflow
Summary
A vulnerability was found in Tenda FH1202 1.2.0.14(408). This impacts the function fromP2pListFilter of the file /goform/P2pListFilter. The manipulation of the argument page results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3811",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-09T18:15:59.458401Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T18:16:40.169Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "m202572177 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14(408). This impacts the function fromP2pListFilter of the file /goform/P2pListFilter. The manipulation of the argument page results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T08:32:09.124Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-349777 | Tenda FH1202 P2pListFilter fromP2pListFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.349777"
},
{
"name": "VDB-349777 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.349777"
},
{
"name": "Submit #769041 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769041"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-p2plistfilter-page-buffer-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-08T17:28:20.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 P2pListFilter fromP2pListFilter stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-3811",
"datePublished": "2026-03-09T08:32:09.124Z",
"dateReserved": "2026-03-08T16:22:56.760Z",
"dateUpdated": "2026-03-09T18:16:40.169Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3810 (GCVE-0-2026-3810)
Vulnerability from nvd – Published: 2026-03-09 08:02 – Updated: 2026-03-10 16:05
VLAI?
Title
Tenda FH1202 DhcpListClient fromDhcpListClient stack-based overflow
Summary
A vulnerability has been found in Tenda FH1202 1.2.0.14(408). This affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3810",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T16:04:58.189848Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T16:05:06.793Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "m202572177 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda FH1202 1.2.0.14(408). This affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T08:02:09.919Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-349776 | Tenda FH1202 DhcpListClient fromDhcpListClient stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.349776"
},
{
"name": "VDB-349776 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.349776"
},
{
"name": "Submit #769040 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769040"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-dhcplistclient-page-buffer-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-08T17:28:19.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 DhcpListClient fromDhcpListClient stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-3810",
"datePublished": "2026-03-09T08:02:09.919Z",
"dateReserved": "2026-03-08T16:22:52.352Z",
"dateUpdated": "2026-03-10T16:05:06.793Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3809 (GCVE-0-2026-3809)
Vulnerability from nvd – Published: 2026-03-09 07:32 – Updated: 2026-03-10 15:32
VLAI?
Title
Tenda FH1202 NatSaticSetting fromNatStaticSetting stack-based overflow
Summary
A flaw has been found in Tenda FH1202 1.2.0.14(408). The impacted element is the function fromNatStaticSetting of the file /goform/NatSaticSetting. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been published and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3809",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T15:31:14.657786Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T15:32:15.234Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "m202572177 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda FH1202 1.2.0.14(408). The impacted element is the function fromNatStaticSetting of the file /goform/NatSaticSetting. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T07:32:11.491Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-349775 | Tenda FH1202 NatSaticSetting fromNatStaticSetting stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.349775"
},
{
"name": "VDB-349775 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.349775"
},
{
"name": "Submit #769039 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769039"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-natsaticsetting-page-buffer-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-08T17:28:18.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 NatSaticSetting fromNatStaticSetting stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-3809",
"datePublished": "2026-03-09T07:32:11.491Z",
"dateReserved": "2026-03-08T16:22:48.509Z",
"dateUpdated": "2026-03-10T15:32:15.234Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3808 (GCVE-0-2026-3808)
Vulnerability from nvd – Published: 2026-03-09 07:02 – Updated: 2026-03-10 15:38
VLAI?
Title
Tenda FH1202 webtypelibrary formWebTypeLibrary stack-based overflow
Summary
A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. Performing a manipulation of the argument webSiteId results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3808",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T15:34:48.440675Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T15:38:14.956Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Manner814 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. Performing a manipulation of the argument webSiteId results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T07:02:08.736Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-349774 | Tenda FH1202 webtypelibrary formWebTypeLibrary stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.349774"
},
{
"name": "VDB-349774 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.349774"
},
{
"name": "Submit #769023 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769023"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-webtypelibrary-websiteid-buffer-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-08T17:28:12.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 webtypelibrary formWebTypeLibrary stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-3808",
"datePublished": "2026-03-09T07:02:08.736Z",
"dateReserved": "2026-03-08T16:22:45.108Z",
"dateUpdated": "2026-03-10T15:38:14.956Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3807 (GCVE-0-2026-3807)
Vulnerability from nvd – Published: 2026-03-09 06:32 – Updated: 2026-03-10 15:44
VLAI?
Title
Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow
Summary
A security vulnerability has been detected in Tenda FH1202 1.2.0.14(408). Impacted is the function formWrlsafeset of the file /goform/AdvSetWrlsafeset. Such manipulation of the argument mit_ssid/mit_ssid_index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3807",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T15:44:02.273541Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T15:44:51.033Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Fan95 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Tenda FH1202 1.2.0.14(408). Impacted is the function formWrlsafeset of the file /goform/AdvSetWrlsafeset. Such manipulation of the argument mit_ssid/mit_ssid_index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T06:32:08.531Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-349773 | Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.349773"
},
{
"name": "VDB-349773 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.349773"
},
{
"name": "Submit #769019 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769019"
},
{
"name": "Submit #769020 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769020"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-advsetwrlsafeset-mit-ssid-buffer-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-08T17:28:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-3807",
"datePublished": "2026-03-09T06:32:08.531Z",
"dateReserved": "2026-03-08T16:22:36.756Z",
"dateUpdated": "2026-03-10T15:44:51.033Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-7532 (GCVE-0-2025-7532)
Vulnerability from nvd – Published: 2025-07-13 16:02 – Updated: 2025-07-14 16:05
VLAI?
Title
Tenda FH1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow
Summary
A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. This vulnerability affects the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7532",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:05:37.210129Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T16:05:45.515Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromwebExcptypemanFilter.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. This vulnerability affects the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH1202 1.2.0.14(408) wurde eine kritische Schwachstelle gefunden. Dabei geht es um die Funktion fromwebExcptypemanFilter der Datei /goform/webExcptypemanFilter. Dank der Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T16:02:08.791Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316228 | Tenda FH1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316228"
},
{
"name": "VDB-316228 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316228"
},
{
"name": "Submit #612958 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612958"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromwebExcptypemanFilter.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:34:00.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7532",
"datePublished": "2025-07-13T16:02:08.791Z",
"dateReserved": "2025-07-12T11:28:45.331Z",
"dateUpdated": "2025-07-14T16:05:45.515Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7531 (GCVE-0-2025-7531)
Vulnerability from nvd – Published: 2025-07-13 15:32 – Updated: 2025-07-14 16:06
VLAI?
Title
Tenda FH1202 PPTPUserSetting fromPptpUserSetting stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7531",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:06:15.761000Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T16:06:18.605Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromPptpUserSetting.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda FH1202 1.2.0.14(408) gefunden. Es geht dabei um die Funktion fromPptpUserSetting der Datei /goform/PPTPUserSetting. Durch Beeinflussen des Arguments delno mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T15:32:06.988Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316227 | Tenda FH1202 PPTPUserSetting fromPptpUserSetting stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316227"
},
{
"name": "VDB-316227 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316227"
},
{
"name": "Submit #612957 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612957"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromPptpUserSetting.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:33:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 PPTPUserSetting fromPptpUserSetting stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7531",
"datePublished": "2025-07-13T15:32:06.988Z",
"dateReserved": "2025-07-12T11:28:42.196Z",
"dateUpdated": "2025-07-14T16:06:18.605Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7530 (GCVE-0-2025-7530)
Vulnerability from nvd – Published: 2025-07-13 15:02 – Updated: 2025-07-14 16:02
VLAI?
Title
Tenda FH1202 PPTPDClient fromPptpUserAdd stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). Affected by this issue is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7530",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:02:41.911215Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T16:02:45.450Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromPptpUserAdd.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). Affected by this issue is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda FH1202 1.2.0.14(408) entdeckt. Es geht hierbei um die Funktion fromPptpUserAdd der Datei /goform/PPTPDClient. Durch das Beeinflussen des Arguments Username mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T15:02:07.201Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316226 | Tenda FH1202 PPTPDClient fromPptpUserAdd stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316226"
},
{
"name": "VDB-316226 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316226"
},
{
"name": "Submit #612956 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612956"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromPptpUserAdd.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:33:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 PPTPDClient fromPptpUserAdd stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7530",
"datePublished": "2025-07-13T15:02:07.201Z",
"dateReserved": "2025-07-12T11:28:39.271Z",
"dateUpdated": "2025-07-14T16:02:45.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7529 (GCVE-0-2025-7529)
Vulnerability from nvd – Published: 2025-07-13 12:02 – Updated: 2025-07-14 16:06
VLAI?
Title
Tenda FH1202 Natlimit fromNatlimit stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda FH1202 1.2.0.14(408). Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7529",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:06:48.256565Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T16:06:51.087Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromNatlimit.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda FH1202 1.2.0.14(408). Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH1202 1.2.0.14(408) wurde eine kritische Schwachstelle entdeckt. Es geht um die Funktion fromNatlimit der Datei /goform/Natlimit. Durch Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T12:02:06.294Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316225 | Tenda FH1202 Natlimit fromNatlimit stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316225"
},
{
"name": "VDB-316225 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316225"
},
{
"name": "Submit #612955 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612955"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromNatlimit.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:33:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 Natlimit fromNatlimit stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7529",
"datePublished": "2025-07-13T12:02:06.294Z",
"dateReserved": "2025-07-12T11:28:36.206Z",
"dateUpdated": "2025-07-14T16:06:51.087Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7528 (GCVE-0-2025-7528)
Vulnerability from nvd – Published: 2025-07-13 11:32 – Updated: 2025-07-15 19:53
VLAI?
Title
Tenda FH1202 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7528",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:44:15.065520Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-15T19:53:48.069Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromGstDhcpSetSer.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda FH1202 1.2.0.14(408) entdeckt. Betroffen hiervon ist die Funktion fromGstDhcpSetSer der Datei /goform/GstDhcpSetSer. Durch das Manipulieren des Arguments dips mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T11:32:06.765Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316224 | Tenda FH1202 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316224"
},
{
"name": "VDB-316224 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316224"
},
{
"name": "Submit #612948 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612948"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromGstDhcpSetSer.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:33:53.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7528",
"datePublished": "2025-07-13T11:32:06.765Z",
"dateReserved": "2025-07-12T11:28:33.573Z",
"dateUpdated": "2025-07-15T19:53:48.069Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7527 (GCVE-0-2025-7527)
Vulnerability from nvd – Published: 2025-07-13 10:32 – Updated: 2025-07-15 19:53
VLAI?
Title
Tenda FH1202 AdvSetWan fromAdvSetWan stack-based overflow
Summary
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function fromAdvSetWan of the file /goform/AdvSetWan. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7527",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:44:20.267791Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-15T19:53:55.891Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromAdvSetWan.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function fromAdvSetWan of the file /goform/AdvSetWan. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda FH1202 1.2.0.14(408) ausgemacht. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion fromAdvSetWan der Datei /goform/AdvSetWan. Mittels Manipulieren des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T10:32:07.306Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316223 | Tenda FH1202 AdvSetWan fromAdvSetWan stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316223"
},
{
"name": "VDB-316223 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316223"
},
{
"name": "Submit #612941 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612941"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromAdvSetWan.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:33:52.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 AdvSetWan fromAdvSetWan stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7527",
"datePublished": "2025-07-13T10:32:07.306Z",
"dateReserved": "2025-07-12T11:28:30.697Z",
"dateUpdated": "2025-07-15T19:53:55.891Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5978 (GCVE-0-2025-5978)
Vulnerability from nvd – Published: 2025-06-10 20:31 – Updated: 2025-06-11 13:48
VLAI?
Title
Tenda FH1202 VirtualSer fromVirtualSer stack-based overflow
Summary
A vulnerability was found in Tenda FH1202 1.2.0.14. It has been classified as critical. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5978",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-11T13:47:20.858863Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-11T13:48:26.258Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-fromVirtualSer-20b53a41781f80b7a6c7e727f93d7d9f"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14. It has been classified as critical. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda FH1202 1.2.0.14 ausgemacht. Hiervon betroffen ist die Funktion fromVirtualSer der Datei /goform/VirtualSer. Mittels Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T20:31:07.787Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311856 | Tenda FH1202 VirtualSer fromVirtualSer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311856"
},
{
"name": "VDB-311856 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311856"
},
{
"name": "Submit #592462 | Tenda FH1202 FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.592462"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-fromVirtualSer-20b53a41781f80b7a6c7e727f93d7d9f?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-10T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-10T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-10T13:53:47.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 VirtualSer fromVirtualSer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5978",
"datePublished": "2025-06-10T20:31:07.787Z",
"dateReserved": "2025-06-10T11:48:44.341Z",
"dateUpdated": "2025-06-11T13:48:26.258Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3237 (GCVE-0-2025-3237)
Vulnerability from nvd – Published: 2025-04-04 10:00 – Updated: 2025-04-04 12:51
VLAI?
Title
Tenda FH1202 wrlwpsset access control
Summary
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects some unknown processing of the file /goform/wrlwpsset. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
5.3 (Medium)
5.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3237",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-04T12:50:20.391141Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T12:51:04.521Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects some unknown processing of the file /goform/wrlwpsset. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda FH1202 1.2.0.14(408) ausgemacht. Sie wurde als kritisch eingestuft. Betroffen davon ist ein unbekannter Prozess der Datei /goform/wrlwpsset. Durch Manipulation mit unbekannten Daten kann eine improper access controls-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-266",
"description": "Incorrect Privilege Assignment",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T10:00:15.289Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-303263 | Tenda FH1202 wrlwpsset access control",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.303263"
},
{
"name": "VDB-303263 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.303263"
},
{
"name": "Submit #546368 | Tenda FH1202 V1.2.0.14(408) Improper Access Controls",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.546368"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-wrlwpsset-1bc53a41781f80aeb9a6de676fe25e6d?pvs=4"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-03T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-03T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-03T20:55:13.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 wrlwpsset access control"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-3237",
"datePublished": "2025-04-04T10:00:15.289Z",
"dateReserved": "2025-04-03T18:50:07.033Z",
"dateUpdated": "2025-04-04T12:51:04.521Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3236 (GCVE-0-2025-3236)
Vulnerability from nvd – Published: 2025-04-04 09:31 – Updated: 2025-04-04 14:27
VLAI?
Title
Tenda FH1202 Web Management Interface VirSerDMZ access control
Summary
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects unknown code of the file /goform/VirSerDMZ of the component Web Management Interface. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
5.3 (Medium)
5.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3236",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-04T14:27:28.286078Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T14:27:44.061Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Management Interface"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects unknown code of the file /goform/VirSerDMZ of the component Web Management Interface. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH1202 1.2.0.14(408) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Betroffen ist eine unbekannte Verarbeitung der Datei /goform/VirSerDMZ der Komponente Web Management Interface. Durch die Manipulation mit unbekannten Daten kann eine improper access controls-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-266",
"description": "Incorrect Privilege Assignment",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T09:31:13.572Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-303262 | Tenda FH1202 Web Management Interface VirSerDMZ access control",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.303262"
},
{
"name": "VDB-303262 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.303262"
},
{
"name": "Submit #546367 | Tenda FH1202 V1.2.0.14(408) Improper Access Controls",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.546367"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-VirSerDMZ-1bc53a41781f809b9e6cdd60fe4e428c?pvs=4"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-03T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-03T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-03T20:55:11.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 Web Management Interface VirSerDMZ access control"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-3236",
"datePublished": "2025-04-04T09:31:13.572Z",
"dateReserved": "2025-04-03T18:50:04.697Z",
"dateUpdated": "2025-04-04T14:27:44.061Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2996 (GCVE-0-2025-2996)
Vulnerability from nvd – Published: 2025-03-31 13:00 – Updated: 2025-03-31 13:25
VLAI?
Title
Tenda FH1202 Web Management Interface SysToolDDNS access control
Summary
A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. This issue affects some unknown processing of the file /goform/SysToolDDNS of the component Web Management Interface. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
5.3 (Medium)
5.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2996",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-31T13:25:00.965966Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-31T13:25:29.294Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Management Interface"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. This issue affects some unknown processing of the file /goform/SysToolDDNS of the component Web Management Interface. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda FH1202 1.2.0.14(408) gefunden. Davon betroffen ist unbekannter Code der Datei /goform/SysToolDDNS der Komponente Web Management Interface. Durch das Manipulieren mit unbekannten Daten kann eine improper access controls-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-266",
"description": "Incorrect Privilege Assignment",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-31T13:00:13.850Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-302045 | Tenda FH1202 Web Management Interface SysToolDDNS access control",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.302045"
},
{
"name": "VDB-302045 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.302045"
},
{
"name": "Submit #523419 | Tenda FH1202 V1.2.0.14(408) Improper Access Controls",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.523419"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-SysToolDDNS-1bc53a41781f8012a03be8bebed1125b?pvs=4"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-30T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-30T19:21:51.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 Web Management Interface SysToolDDNS access control"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2996",
"datePublished": "2025-03-31T13:00:13.850Z",
"dateReserved": "2025-03-30T17:16:06.774Z",
"dateUpdated": "2025-03-31T13:25:29.294Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2995 (GCVE-0-2025-2995)
Vulnerability from nvd – Published: 2025-03-31 12:31 – Updated: 2025-03-31 14:19
VLAI?
Title
Tenda FH1202 Web Management Interface SysToolChangePwd access control
Summary
A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. This vulnerability affects unknown code of the file /goform/SysToolChangePwd of the component Web Management Interface. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
5.3 (Medium)
5.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2995",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-31T14:19:31.545160Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-31T14:19:46.183Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-SysToolChangePwd-1bc53a41781f809b95a4efb617090d3c"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Management Interface"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_backup (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. This vulnerability affects unknown code of the file /goform/SysToolChangePwd of the component Web Management Interface. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH1202 1.2.0.14(408) wurde eine kritische Schwachstelle gefunden. Hierbei betrifft es unbekannten Programmcode der Datei /goform/SysToolChangePwd der Komponente Web Management Interface. Mittels Manipulieren mit unbekannten Daten kann eine improper access controls-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-266",
"description": "Incorrect Privilege Assignment",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-31T12:31:11.879Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-302044 | Tenda FH1202 Web Management Interface SysToolChangePwd access control",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.302044"
},
{
"name": "VDB-302044 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.302044"
},
{
"name": "Submit #523418 | Tenda FH1202 V1.2.0.14(408) Improper Access Controls",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.523418"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-SysToolChangePwd-1bc53a41781f809b95a4efb617090d3c?pvs=4"
},
{
"tags": [
"broken-link",
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-30T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-30T19:21:19.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 Web Management Interface SysToolChangePwd access control"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-2995",
"datePublished": "2025-03-31T12:31:11.879Z",
"dateReserved": "2025-03-30T17:16:04.442Z",
"dateUpdated": "2025-03-31T14:19:46.183Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-3811 (GCVE-0-2026-3811)
Vulnerability from cvelistv5 – Published: 2026-03-09 08:32 – Updated: 2026-03-09 18:16
VLAI?
Title
Tenda FH1202 P2pListFilter fromP2pListFilter stack-based overflow
Summary
A vulnerability was found in Tenda FH1202 1.2.0.14(408). This impacts the function fromP2pListFilter of the file /goform/P2pListFilter. The manipulation of the argument page results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3811",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-09T18:15:59.458401Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T18:16:40.169Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "m202572177 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14(408). This impacts the function fromP2pListFilter of the file /goform/P2pListFilter. The manipulation of the argument page results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T08:32:09.124Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-349777 | Tenda FH1202 P2pListFilter fromP2pListFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.349777"
},
{
"name": "VDB-349777 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.349777"
},
{
"name": "Submit #769041 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769041"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-p2plistfilter-page-buffer-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-08T17:28:20.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 P2pListFilter fromP2pListFilter stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-3811",
"datePublished": "2026-03-09T08:32:09.124Z",
"dateReserved": "2026-03-08T16:22:56.760Z",
"dateUpdated": "2026-03-09T18:16:40.169Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3810 (GCVE-0-2026-3810)
Vulnerability from cvelistv5 – Published: 2026-03-09 08:02 – Updated: 2026-03-10 16:05
VLAI?
Title
Tenda FH1202 DhcpListClient fromDhcpListClient stack-based overflow
Summary
A vulnerability has been found in Tenda FH1202 1.2.0.14(408). This affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3810",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T16:04:58.189848Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T16:05:06.793Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "m202572177 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda FH1202 1.2.0.14(408). This affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T08:02:09.919Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-349776 | Tenda FH1202 DhcpListClient fromDhcpListClient stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.349776"
},
{
"name": "VDB-349776 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.349776"
},
{
"name": "Submit #769040 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769040"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-dhcplistclient-page-buffer-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-08T17:28:19.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 DhcpListClient fromDhcpListClient stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-3810",
"datePublished": "2026-03-09T08:02:09.919Z",
"dateReserved": "2026-03-08T16:22:52.352Z",
"dateUpdated": "2026-03-10T16:05:06.793Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3809 (GCVE-0-2026-3809)
Vulnerability from cvelistv5 – Published: 2026-03-09 07:32 – Updated: 2026-03-10 15:32
VLAI?
Title
Tenda FH1202 NatSaticSetting fromNatStaticSetting stack-based overflow
Summary
A flaw has been found in Tenda FH1202 1.2.0.14(408). The impacted element is the function fromNatStaticSetting of the file /goform/NatSaticSetting. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been published and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3809",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T15:31:14.657786Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T15:32:15.234Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "m202572177 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda FH1202 1.2.0.14(408). The impacted element is the function fromNatStaticSetting of the file /goform/NatSaticSetting. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T07:32:11.491Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-349775 | Tenda FH1202 NatSaticSetting fromNatStaticSetting stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.349775"
},
{
"name": "VDB-349775 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.349775"
},
{
"name": "Submit #769039 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769039"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-natsaticsetting-page-buffer-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-08T17:28:18.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 NatSaticSetting fromNatStaticSetting stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-3809",
"datePublished": "2026-03-09T07:32:11.491Z",
"dateReserved": "2026-03-08T16:22:48.509Z",
"dateUpdated": "2026-03-10T15:32:15.234Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3808 (GCVE-0-2026-3808)
Vulnerability from cvelistv5 – Published: 2026-03-09 07:02 – Updated: 2026-03-10 15:38
VLAI?
Title
Tenda FH1202 webtypelibrary formWebTypeLibrary stack-based overflow
Summary
A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. Performing a manipulation of the argument webSiteId results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3808",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T15:34:48.440675Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T15:38:14.956Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Manner814 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. Performing a manipulation of the argument webSiteId results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T07:02:08.736Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-349774 | Tenda FH1202 webtypelibrary formWebTypeLibrary stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.349774"
},
{
"name": "VDB-349774 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.349774"
},
{
"name": "Submit #769023 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769023"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-webtypelibrary-websiteid-buffer-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-08T17:28:12.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 webtypelibrary formWebTypeLibrary stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-3808",
"datePublished": "2026-03-09T07:02:08.736Z",
"dateReserved": "2026-03-08T16:22:45.108Z",
"dateUpdated": "2026-03-10T15:38:14.956Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3807 (GCVE-0-2026-3807)
Vulnerability from cvelistv5 – Published: 2026-03-09 06:32 – Updated: 2026-03-10 15:44
VLAI?
Title
Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow
Summary
A security vulnerability has been detected in Tenda FH1202 1.2.0.14(408). Impacted is the function formWrlsafeset of the file /goform/AdvSetWrlsafeset. Such manipulation of the argument mit_ssid/mit_ssid_index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3807",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-10T15:44:02.273541Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-10T15:44:51.033Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Fan95 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Tenda FH1202 1.2.0.14(408). Impacted is the function formWrlsafeset of the file /goform/AdvSetWrlsafeset. Such manipulation of the argument mit_ssid/mit_ssid_index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T06:32:08.531Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-349773 | Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.349773"
},
{
"name": "VDB-349773 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.349773"
},
{
"name": "Submit #769019 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769019"
},
{
"name": "Submit #769020 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769020"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-advsetwrlsafeset-mit-ssid-buffer-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-08T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-08T17:28:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-3807",
"datePublished": "2026-03-09T06:32:08.531Z",
"dateReserved": "2026-03-08T16:22:36.756Z",
"dateUpdated": "2026-03-10T15:44:51.033Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-7532 (GCVE-0-2025-7532)
Vulnerability from cvelistv5 – Published: 2025-07-13 16:02 – Updated: 2025-07-14 16:05
VLAI?
Title
Tenda FH1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow
Summary
A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. This vulnerability affects the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7532",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:05:37.210129Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T16:05:45.515Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromwebExcptypemanFilter.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. This vulnerability affects the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH1202 1.2.0.14(408) wurde eine kritische Schwachstelle gefunden. Dabei geht es um die Funktion fromwebExcptypemanFilter der Datei /goform/webExcptypemanFilter. Dank der Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T16:02:08.791Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316228 | Tenda FH1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316228"
},
{
"name": "VDB-316228 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316228"
},
{
"name": "Submit #612958 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612958"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromwebExcptypemanFilter.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:34:00.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7532",
"datePublished": "2025-07-13T16:02:08.791Z",
"dateReserved": "2025-07-12T11:28:45.331Z",
"dateUpdated": "2025-07-14T16:05:45.515Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7531 (GCVE-0-2025-7531)
Vulnerability from cvelistv5 – Published: 2025-07-13 15:32 – Updated: 2025-07-14 16:06
VLAI?
Title
Tenda FH1202 PPTPUserSetting fromPptpUserSetting stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7531",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:06:15.761000Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T16:06:18.605Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromPptpUserSetting.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda FH1202 1.2.0.14(408) gefunden. Es geht dabei um die Funktion fromPptpUserSetting der Datei /goform/PPTPUserSetting. Durch Beeinflussen des Arguments delno mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T15:32:06.988Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316227 | Tenda FH1202 PPTPUserSetting fromPptpUserSetting stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316227"
},
{
"name": "VDB-316227 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316227"
},
{
"name": "Submit #612957 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612957"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromPptpUserSetting.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:33:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 PPTPUserSetting fromPptpUserSetting stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7531",
"datePublished": "2025-07-13T15:32:06.988Z",
"dateReserved": "2025-07-12T11:28:42.196Z",
"dateUpdated": "2025-07-14T16:06:18.605Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7530 (GCVE-0-2025-7530)
Vulnerability from cvelistv5 – Published: 2025-07-13 15:02 – Updated: 2025-07-14 16:02
VLAI?
Title
Tenda FH1202 PPTPDClient fromPptpUserAdd stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). Affected by this issue is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7530",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:02:41.911215Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T16:02:45.450Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromPptpUserAdd.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). Affected by this issue is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda FH1202 1.2.0.14(408) entdeckt. Es geht hierbei um die Funktion fromPptpUserAdd der Datei /goform/PPTPDClient. Durch das Beeinflussen des Arguments Username mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T15:02:07.201Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316226 | Tenda FH1202 PPTPDClient fromPptpUserAdd stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316226"
},
{
"name": "VDB-316226 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316226"
},
{
"name": "Submit #612956 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612956"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromPptpUserAdd.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:33:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 PPTPDClient fromPptpUserAdd stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7530",
"datePublished": "2025-07-13T15:02:07.201Z",
"dateReserved": "2025-07-12T11:28:39.271Z",
"dateUpdated": "2025-07-14T16:02:45.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7529 (GCVE-0-2025-7529)
Vulnerability from cvelistv5 – Published: 2025-07-13 12:02 – Updated: 2025-07-14 16:06
VLAI?
Title
Tenda FH1202 Natlimit fromNatlimit stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda FH1202 1.2.0.14(408). Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7529",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:06:48.256565Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T16:06:51.087Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromNatlimit.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda FH1202 1.2.0.14(408). Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH1202 1.2.0.14(408) wurde eine kritische Schwachstelle entdeckt. Es geht um die Funktion fromNatlimit der Datei /goform/Natlimit. Durch Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T12:02:06.294Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316225 | Tenda FH1202 Natlimit fromNatlimit stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316225"
},
{
"name": "VDB-316225 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316225"
},
{
"name": "Submit #612955 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612955"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromNatlimit.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:33:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 Natlimit fromNatlimit stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7529",
"datePublished": "2025-07-13T12:02:06.294Z",
"dateReserved": "2025-07-12T11:28:36.206Z",
"dateUpdated": "2025-07-14T16:06:51.087Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7528 (GCVE-0-2025-7528)
Vulnerability from cvelistv5 – Published: 2025-07-13 11:32 – Updated: 2025-07-15 19:53
VLAI?
Title
Tenda FH1202 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7528",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:44:15.065520Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-15T19:53:48.069Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromGstDhcpSetSer.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda FH1202 1.2.0.14(408) entdeckt. Betroffen hiervon ist die Funktion fromGstDhcpSetSer der Datei /goform/GstDhcpSetSer. Durch das Manipulieren des Arguments dips mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T11:32:06.765Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316224 | Tenda FH1202 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316224"
},
{
"name": "VDB-316224 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316224"
},
{
"name": "Submit #612948 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612948"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromGstDhcpSetSer.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:33:53.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7528",
"datePublished": "2025-07-13T11:32:06.765Z",
"dateReserved": "2025-07-12T11:28:33.573Z",
"dateUpdated": "2025-07-15T19:53:48.069Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7527 (GCVE-0-2025-7527)
Vulnerability from cvelistv5 – Published: 2025-07-13 10:32 – Updated: 2025-07-15 19:53
VLAI?
Title
Tenda FH1202 AdvSetWan fromAdvSetWan stack-based overflow
Summary
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function fromAdvSetWan of the file /goform/AdvSetWan. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7527",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:44:20.267791Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-15T19:53:55.891Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromAdvSetWan.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function fromAdvSetWan of the file /goform/AdvSetWan. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda FH1202 1.2.0.14(408) ausgemacht. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion fromAdvSetWan der Datei /goform/AdvSetWan. Mittels Manipulieren des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T10:32:07.306Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316223 | Tenda FH1202 AdvSetWan fromAdvSetWan stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316223"
},
{
"name": "VDB-316223 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316223"
},
{
"name": "Submit #612941 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.612941"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1202/fromAdvSetWan.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T13:33:52.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 AdvSetWan fromAdvSetWan stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7527",
"datePublished": "2025-07-13T10:32:07.306Z",
"dateReserved": "2025-07-12T11:28:30.697Z",
"dateUpdated": "2025-07-15T19:53:55.891Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5978 (GCVE-0-2025-5978)
Vulnerability from cvelistv5 – Published: 2025-06-10 20:31 – Updated: 2025-06-11 13:48
VLAI?
Title
Tenda FH1202 VirtualSer fromVirtualSer stack-based overflow
Summary
A vulnerability was found in Tenda FH1202 1.2.0.14. It has been classified as critical. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5978",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-11T13:47:20.858863Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-11T13:48:26.258Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-fromVirtualSer-20b53a41781f80b7a6c7e727f93d7d9f"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14. It has been classified as critical. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda FH1202 1.2.0.14 ausgemacht. Hiervon betroffen ist die Funktion fromVirtualSer der Datei /goform/VirtualSer. Mittels Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T20:31:07.787Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311856 | Tenda FH1202 VirtualSer fromVirtualSer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311856"
},
{
"name": "VDB-311856 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311856"
},
{
"name": "Submit #592462 | Tenda FH1202 FH1202 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.592462"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-fromVirtualSer-20b53a41781f80b7a6c7e727f93d7d9f?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-10T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-10T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-10T13:53:47.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 VirtualSer fromVirtualSer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5978",
"datePublished": "2025-06-10T20:31:07.787Z",
"dateReserved": "2025-06-10T11:48:44.341Z",
"dateUpdated": "2025-06-11T13:48:26.258Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3237 (GCVE-0-2025-3237)
Vulnerability from cvelistv5 – Published: 2025-04-04 10:00 – Updated: 2025-04-04 12:51
VLAI?
Title
Tenda FH1202 wrlwpsset access control
Summary
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects some unknown processing of the file /goform/wrlwpsset. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
5.3 (Medium)
5.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3237",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-04T12:50:20.391141Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T12:51:04.521Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects some unknown processing of the file /goform/wrlwpsset. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda FH1202 1.2.0.14(408) ausgemacht. Sie wurde als kritisch eingestuft. Betroffen davon ist ein unbekannter Prozess der Datei /goform/wrlwpsset. Durch Manipulation mit unbekannten Daten kann eine improper access controls-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-266",
"description": "Incorrect Privilege Assignment",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T10:00:15.289Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-303263 | Tenda FH1202 wrlwpsset access control",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.303263"
},
{
"name": "VDB-303263 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.303263"
},
{
"name": "Submit #546368 | Tenda FH1202 V1.2.0.14(408) Improper Access Controls",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.546368"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-wrlwpsset-1bc53a41781f80aeb9a6de676fe25e6d?pvs=4"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-03T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-03T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-03T20:55:13.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 wrlwpsset access control"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-3237",
"datePublished": "2025-04-04T10:00:15.289Z",
"dateReserved": "2025-04-03T18:50:07.033Z",
"dateUpdated": "2025-04-04T12:51:04.521Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3236 (GCVE-0-2025-3236)
Vulnerability from cvelistv5 – Published: 2025-04-04 09:31 – Updated: 2025-04-04 14:27
VLAI?
Title
Tenda FH1202 Web Management Interface VirSerDMZ access control
Summary
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects unknown code of the file /goform/VirSerDMZ of the component Web Management Interface. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
5.3 (Medium)
5.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3236",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-04T14:27:28.286078Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T14:27:44.061Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Management Interface"
],
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects unknown code of the file /goform/VirSerDMZ of the component Web Management Interface. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH1202 1.2.0.14(408) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Betroffen ist eine unbekannte Verarbeitung der Datei /goform/VirSerDMZ der Komponente Web Management Interface. Durch die Manipulation mit unbekannten Daten kann eine improper access controls-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-266",
"description": "Incorrect Privilege Assignment",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T09:31:13.572Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-303262 | Tenda FH1202 Web Management Interface VirSerDMZ access control",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.303262"
},
{
"name": "VDB-303262 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.303262"
},
{
"name": "Submit #546367 | Tenda FH1202 V1.2.0.14(408) Improper Access Controls",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.546367"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-FH1202-VirSerDMZ-1bc53a41781f809b9e6cdd60fe4e428c?pvs=4"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-03T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-03T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-03T20:55:11.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 Web Management Interface VirSerDMZ access control"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-3236",
"datePublished": "2025-04-04T09:31:13.572Z",
"dateReserved": "2025-04-03T18:50:04.697Z",
"dateUpdated": "2025-04-04T14:27:44.061Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}