Search

Find a vulnerability

Search criteria

    124 vulnerabilities found for edk2 by tianocore

    FKIE_CVE-2026-111497

    Vulnerability from fkie_nvd - Published: 2026-10-22 14:17 - Updated: 2026-11-24 15:17
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    References
    cve-coordination@google.comhttps://github.com/andybalholm/brotli/releases/tag/v1.2.7Release Notes
    cve-coordination@google.comhttps://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---highThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/23/25Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/24/6Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/26/12Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/26/13Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/26/16Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/11/03/2Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://broccoli2shell.comThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/advisories/GHSA-9v8h-qqgm-4m35Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/dotnet/announcements/issues/494Issue Tracking, Mitigation, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/google/brotli/releases/tag/v1.0.10Release Notes
    af854a3a-2127-422b-91ae-364da2661108https://github.com/google/brotli/releases/tag/v1.1.1Release Notes
    af854a3a-2127-422b-91ae-364da2661108https://github.com/google/brotli/releases/tag/v1.2.1Release Notes
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2026/10/msg00049.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://patchtheplanet.org/brotliThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497Third Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-045512.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-242944.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-443410.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-678870.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-898633.htmlThird Party Advisory
    134c704f-9b21-4f2e-91b3-4a467353bcc0https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/Third Party Advisory
    134c704f-9b21-4f2e-91b3-4a467353bcc0https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497US Government Resource
    Impacted products
    Vendor Product Version
    google brotli *
    google brotli *
    google brotli *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    python-hyper brotlicffi *
    microsoft .net *
    microsoft .net *
    microsoft .net *
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    debian debian_linux 12.0
    istio istio *
    istio istio *
    istio istio *
    anthropic bun *
    envoyproxy envoy *
    envoyproxy envoy *
    envoyproxy envoy *
    tianocore edk2 *
    google woff2 -
    duckdb duckdb *
    clickhouse clickhouse *
    apache arrow *
    apache arrow 27.0.0
    mcmilk 7-zip-zstd *
    7-zip p7zip *
    andybalholm brotli *
    siemens ruggedcom_ape1808_firmware -
    siemens ruggedcom_ape1808 -
    siemens common_configurator -
    siemens data_flow_monitoring *
    siemens dataxess_configurator *
    siemens edge_opc_ua_server_configurator *
    siemens flow_creator_configurator *
    siemens industrial_edge_cloud_connector_configurator *
    siemens industrial_edge_databus_configurator *
    siemens industrial_edge_hub -
    siemens industrial_edge_management_cloud -
    siemens comos_walkinside -
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_profiling_tool -
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_wincc *
    siemens simatic_wincc_companion -
    siemens simatic_wincc_runtime -
    siemens simatic_wincc_unified_for_industrial_edge -
    siemens simatic_wincc_unified_pc_runtime -
    siemens simatic_wincc_unified_siqence -
    siemens tia_administrator -
    siemens tia_project-server_web_administration_tool -
    siemens user_management_component -
    siemens hyperlynx -
    siemens innexis_architecture_native_acceleration -
    siemens insights_hub -
    siemens opcenter_connect_electronics -
    siemens opcenter_connect_manufacturing_operations_management -
    siemens opcenter_execution_core -
    siemens opcenter_execution_discrete -
    siemens opcenter_execution_foundation -
    siemens opcenter_execution_pharma -
    siemens opcenter_execution_process -
    siemens opcenter_intelligence -
    siemens opcenter_quality -
    siemens opcenter_rd\&l -
    siemens opcenter_x -
    siemens pads_professional -
    siemens pads_professional -
    siemens pave360_automotive 2026
    siemens process_preparation_x -
    siemens simcenter_executable_digital_twin -
    siemens simcenter_studio -
    siemens teamcenter 2412.0
    siemens teamcenter 2506.0
    siemens teamcenter 2512.0
    siemens teamcenter 2606.0
    siemens xpedition_designer -
    siemens xpedition_enterprise -

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "cve-coordination@google.com"
        },
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 100 NX3 M8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 100 NX3 M8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 125 NX3 M10",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "COMOS Walkinside",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC family V8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC family V9",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "gDAP (gPROMS Digital Application Platform)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Gridscale X DSA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.4",
                  "status": "affected",
                  "version": "V5.3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Gridscale X PSS\u00aeE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V36.8.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Heliox Dual Port 60kW",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Heliox Flex Pro",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Integrated PA Suite Tester",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "INTRALOG WMS Kronos",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "INTRALOG WMS Kronos",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Project Server Web Administration Tool",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE LPE9403 (6GK5998-3GS00-2AC2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE LPE9413 (6GK5998-3GS01-2AC2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE LPE9423",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE LPE9433 (6GK5998-3GS11-2AC2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SENTRON Powermanager V8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SENTRON Powermanager V9",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICAM PAS CC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V6.02",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICAM SCC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V7.01",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICHARGE FLEX",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICHARGE UC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Sifinity Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Sifinity Setup",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC BRAUMAT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.2 Update 5",
                  "status": "affected",
                  "version": "V8.2 Update 1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Profiling Tool",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC SISTAR",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.2 Update 5",
                  "status": "affected",
                  "version": "V8.2 Update 1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Companion",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC OA V3.20",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.20.17.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC OA V3.21",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.21.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Runtime Professional",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Unified for Industrial Edge",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Unified PC Runtime",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Unified SIQENCE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V7/V8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC INS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEMA Remote Connect Client",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEMA Remote Connect Edge Client",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SITOP Manager",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "VersiCharge AC Series",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "VersiCloud",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Cloud Connector Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.24.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Common Configurator\u00a0(CC on IEM)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Common Configurator on Device\u00a0(CC on Edge)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Data Flow Monitoring",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.18",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Databus Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "DataXess Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.5.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Edge OPC UA Server Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Flow Creator Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Industrial Edge Hub",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Industrial Edge Management Cloud",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "HyperLynx",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Innexis Architecture Native Acceleration 2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Insights Hub",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Connect Electronics",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Connect MOM",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Core",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Discrete",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Pharma",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Process",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Intelligence",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Intra Plant Logistics",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter RDnL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter X",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PADS Pro Essentials",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PADS Pro Student Edition",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PADS Professional",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PAVE360 Automotive 2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Process Preparation X",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Executable Digital Twin",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Studio",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2506",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2512",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2606",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Xpedition Designer",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Xpedition Enterprise",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
        }
      ],
      "cisaActionDue": "2026-11-10",
      "cisaExploitAdd": "2026-10-27",
      "cisaRequiredAction": "Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA\u2019s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA\u2019s \u201cForensics Triage Requirements\u201d (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset\u0027s internet exposure and ensuring adherence to BOD 26-04 patching guidelines.",
      "cisaVulnerabilityName": "Google Brotli Unchecked Return Value Vulnerability",
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
                  "matchCriteriaId": "8A7BE60F-21B0-4779-8D59-6E5E58C5826B",
                  "versionEndExcluding": "1.0.10",
                  "versionStartIncluding": "1.0.3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
                  "matchCriteriaId": "48E72297-AFBD-4460-A732-5A6803CCCDB0",
                  "versionEndExcluding": "1.1.1",
                  "versionStartIncluding": "1.1.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
                  "matchCriteriaId": "C8CA5C74-26A8-44E3-B893-1FA01CED49F5",
                  "versionEndExcluding": "1.2.1",
                  "versionStartIncluding": "1.2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "02348F18-5E17-4427-8B78-63B4082F2FB4",
                  "versionEndExcluding": "22.23.4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "852D09BB-A396-4813-81C9-7D89D5DD5FB6",
                  "versionEndExcluding": "24.22.1",
                  "versionStartIncluding": "23.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "219CA855-3A40-42CE-BAB6-79CCFEE7746F",
                  "versionEndExcluding": "26.12.1",
                  "versionStartIncluding": "25.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:python-hyper:brotlicffi:*:*:*:*:*:python:*:*",
                  "matchCriteriaId": "E732E75B-4BEF-4D7E-8520-E03B707FB4F6",
                  "versionEndExcluding": "1.2.1.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "65DCE51C-2CD9-4179-9354-5323D28573AA",
                  "versionEndExcluding": "8.0.33",
                  "versionStartIncluding": "8.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "98654489-8C4E-4801-8728-29B01A22DEED",
                  "versionEndExcluding": "9.0.22",
                  "versionStartIncluding": "9.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "27DF5CF4-58E3-4F01-A3AA-D44B7DCC3D67",
                  "versionEndExcluding": "10.0.14",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview1:*:*:*:*:*:*",
                  "matchCriteriaId": "5DACF2FE-CF61-43E4-8A3F-F7A358DE8A01",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview2:*:*:*:*:*:*",
                  "matchCriteriaId": "280B2E64-3163-40AB-A048-14D58DEC42FD",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview3:*:*:*:*:*:*",
                  "matchCriteriaId": "12357908-3294-46EF-85A0-DA3F86C97489",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview4:*:*:*:*:*:*",
                  "matchCriteriaId": "849FC8F5-86CD-4B5D-ADFD-9CB16EA75D09",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview5:*:*:*:*:*:*",
                  "matchCriteriaId": "C86E87E2-B236-4AC9-B6C3-64B9CDEC91EB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview6:*:*:*:*:*:*",
                  "matchCriteriaId": "9B14656E-2BB0-4B4B-B518-F3D5108253ED",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview7:*:*:*:*:*:*",
                  "matchCriteriaId": "E09C9DB3-F42C-4442-9CF0-24A780D094C8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:rc1:*:*:*:*:*:*",
                  "matchCriteriaId": "67035E86-61F5-421E-B243-EF64458AD8BA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:rc2:*:*:*:*:*:*",
                  "matchCriteriaId": "C46300CA-BA84-48B3-85C5-C20CB487C733",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:12.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "46D69DCC-AE4D-4EA5-861C-D60951444C6C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9F01FA9D-7190-431F-84DD-24D4EBC41A2D",
                  "versionEndExcluding": "1.29.9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B8DE25CE-AFCB-4685-9836-B8EC9C820975",
                  "versionEndExcluding": "1.30.6",
                  "versionStartIncluding": "1.30.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "55EBE231-2EB8-4C9C-B279-D07F82EA5B55",
                  "versionEndExcluding": "1.31.2",
                  "versionStartIncluding": "1.31.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:anthropic:bun:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "51DD72B3-85F6-4B10-AEB4-41E0679ED0AA",
                  "versionEndExcluding": "1.4.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE6278D-A48A-427C-8A7E-1D4103E2ADF7",
                  "versionEndExcluding": "1.37.8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDCA301F-83CA-4DDB-AAE4-24D5235EE2D5",
                  "versionEndExcluding": "1.38.6",
                  "versionStartIncluding": "1.38.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B9A47DD3-2655-4722-9B9D-3888B590C82F",
                  "versionEndExcluding": "1.39.3",
                  "versionStartIncluding": "1.39.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C4CFCBFB-4A38-481B-93AE-7D86CCDC6FB5",
                  "versionEndIncluding": "202608",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:google:woff2:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6D1FC23A-20F7-48F7-ABB8-8D37903DFB58",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:duckdb:duckdb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0DFA4F95-92F9-4369-BE42-387520F0765B",
                  "versionEndIncluding": "2.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:clickhouse:clickhouse:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B40EE389-E2AC-4D86-91B2-79A895470317",
                  "versionEndIncluding": "26.10.2.103",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:apache:arrow:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "46A78CA5-1E4A-4DAA-B40D-387B96C1E2F9",
                  "versionEndIncluding": "26.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:apache:arrow:27.0.0:dev:*:*:*:*:*:*",
                  "matchCriteriaId": "130A7077-7885-43CB-8AFF-B6056D380156",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mcmilk:7-zip-zstd:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FB91A353-9BE9-49E7-86FD-6B5FBB291351",
                  "versionEndIncluding": "26.02-1.5.7-r2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:7-zip:p7zip:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "76A26292-08BE-459A-B25A-CA14AF8D3C29",
                  "versionEndIncluding": "16.02",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:andybalholm:brotli:*:*:*:*:*:go:*:*",
                  "matchCriteriaId": "F3E50F12-AEFE-4B4F-B474-3676F145E032",
                  "versionEndExcluding": "1.2.7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "37FDCA69-9049-40B4-88AF-F476901022B6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:ruggedcom_ape1808:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B89A6863-B602-4404-8D26-337FECABFFF0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:common_configurator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1F93AD0A-C29E-4FA6-A18B-1F0D03CC900C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:data_flow_monitoring:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3562BB8C-6E76-4B16-A2EF-D343EED30DA0",
                  "versionEndExcluding": "3.0.18",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:dataxess_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "076198F2-9992-4803-8377-8B264E1D7ADA",
                  "versionEndExcluding": "1.5.7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:edge_opc_ua_server_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F1122EBA-DB7C-4680-AEEF-309C95843D0D",
                  "versionEndExcluding": "2.3.10",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:flow_creator_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90BE4EB2-0B14-44F4-881D-F0DBAFCEF322",
                  "versionEndExcluding": "1.15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_cloud_connector_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D0E0C6F6-40D0-4D71-ABCE-84449C4E743A",
                  "versionEndExcluding": "1.24.3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_databus_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B57AD29D-69CF-4C76-AACA-3EAE3F8CBC15",
                  "versionEndExcluding": "4.0.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_hub:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "70BA5718-0A9F-4B7D-9175-D6719B795363",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_management_cloud:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4EA7E869-9428-4D5E-95C0-F19B6BC1BFA9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:comos_walkinside:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8C7AAED9-567F-4EE0-BC1B-F18E1109D316",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "EFA8804E-1E7E-482F-A701-B988F6C0BCE9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "A7C12A3B-925A-4219-909B-6D2D0ADA6131",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "3288CF66-F9D9-4DDD-9CAA-1EB2E075C87A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "9B3EF16B-8281-4159-ABDE-A36881CD8460",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "9DF55BA1-F06B-4868-AC51-15ADC8BFED3C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_profiling_tool:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0D473CE5-B139-422C-AFCF-5FBBDB2C0759",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "28A180EC-5DB8-4E8A-B063-813FA3973068",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "31122237-42B0-4B10-B33B-D6E6DEBC19B3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "2955D58B-350F-4F96-A41F-6594639403DA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "0E95149C-B212-4670-8DFC-EEC713E87741",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "173F36F4-23F4-4650-805F-25A9032AF64A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DA06F4BD-1512-4700-AD3E-25C6CDA60246",
                  "versionEndIncluding": "8.2",
                  "versionStartIncluding": "7.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_companion:-:*:*:*:*:-:*:*",
                  "matchCriteriaId": "174C0674-3100-4CCB-B55E-6BB1FB8F8442",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*",
                  "matchCriteriaId": "E6BFBAED-EE2B-4DE4-A76C-824DD15F4608",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_for_industrial_edge:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4DC1EDC8-DA6D-476F-9656-0FB9809F9E30",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_pc_runtime:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "49B72BEA-DE75-4A5E-8658-30E5EBBFFF69",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_siqence:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E2E193FF-ED70-432A-8B33-2453A8B2B21B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FC8C7680-9033-4ECF-9764-5179A4033F64",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:tia_project-server_web_administration_tool:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14BA6E1D-4D4E-4133-8869-5ADEC9CE545C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:user_management_component:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7139EEDB-2DCD-4C55-9DAC-423FB5807D11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:hyperlynx:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "92D6ED26-34E3-46A6-B025-F7DC263AA75A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:innexis_architecture_native_acceleration:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BE57EA6F-BA70-409D-B037-EDD603FAC0B9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:insights_hub:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1B8E91A0-4BF0-4BDE-8F83-4FF374697A76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_connect_electronics:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0EC96381-D0C9-4949-86E7-1A1E8239A8F2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_connect_manufacturing_operations_management:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0F5FAC2-E6E0-4ECA-86B6-9D082C1D674B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_core:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0A6E1786-F0A9-498F-9DE9-F503B5DAD84A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F04BAB87-71BB-4AB4-BC42-F89616698EEF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FE353B7-07A1-4B50-8A43-62577C2208EE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_pharma:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4CC50DA8-906E-4BD5-9861-668273EE3A76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_process:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CCA2643-1E89-49AE-B8CB-3A9CDA3031A6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_intelligence:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E3FA7CB-6931-4D0C-A3E6-1BE71EA0D30F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "69EDC5E0-6CCE-4120-913C-E598E0FE2D24",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A12051E1-2DC9-47C6-A320-927D0A7B9F47",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:pads_professional:-:*:*:*:essentials:*:*:*",
                  "matchCriteriaId": "C9033337-D032-403D-8BBF-3EA50253A40E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:pads_professional:-:*:*:*:student:*:*:*",
                  "matchCriteriaId": "F06B80D2-6A35-4AF5-A07A-0F5C3370C3E7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:pave360_automotive:2026:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B8DBFD9C-B213-4238-B39C-D4B537523CB1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:process_preparation_x:-:*:*:*:-:*:*:*",
                  "matchCriteriaId": "FEBDB60C-D759-476D-AF06-3C0691FC72CF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simcenter_executable_digital_twin:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F6ACF933-A876-4DE5-BBA7-D5BF97DB1AB4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simcenter_studio:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B8C684EC-BECB-4833-B1F9-F773225A6172",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2412.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "963C8AAA-D3E0-4B10-93AE-DB15619EC5EE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2506.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "261C46FE-1C63-4A1F-8C8E-FC331E8F119E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2512.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7946C16C-5B81-42D2-BA6D-C8AA8FD5AD0C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2606.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86E64B27-FE8F-45AD-BE78-219E4067F8DE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:xpedition_designer:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F52F6405-0228-4C3D-842F-839192076657",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:xpedition_enterprise:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD525494-2807-48EA-AED0-11B9CB5A6A9B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
        }
      ],
      "id": "CVE-2026-111497",
      "lastModified": "2026-11-24T15:17:09.400",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "PRESENT",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 9.2,
              "baseSeverity": "CRITICAL",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@google.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-111497",
              "options": [
                {
                  "exploitation": "active"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-23T00:00:00+00:00",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-10-22T14:17:37.190",
      "references": [
        {
          "source": "cve-coordination@google.com",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
        },
        {
          "source": "cve-coordination@google.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://broccoli2shell.com"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking",
            "Mitigation",
            "Third Party Advisory"
          ],
          "url": "https://github.com/dotnet/announcements/issues/494"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://patchtheplanet.org/brotli"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
        },
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
        },
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "tags": [
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
        }
      ],
      "sourceIdentifier": "cve-coordination@google.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-252"
            },
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "cve-coordination@google.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-2486

    Vulnerability from fkie_nvd - Published: 2025-11-26 18:15 - Updated: 2026-10-18 20:10
    Summary
    The Ubuntu edk2 UEFI firmware packages accidentally allowed the UEFI Shell to be accessed in Secure Boot environments, possibly allowing bypass of Secure Boot constraints. Versions 2024.05-2ubuntu0.3 and 2024.02-2ubuntu0.3 disable the Shell. Some previous versions inserted a secure-boot-based decision to continue running inside the Shell itself, which is believed to be sufficient to enforce Secure Boot restrictions. This is an additional repair on top of the incomplete fix for CVE-2023-48733.
    Impacted products
    Vendor Product Version
    tianocore edk2 202402*
    tianocore edk2 202405

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "AAVMF UEFI Shell"
              ],
              "platforms": [
                "aarch64"
              ],
              "product": "edk2",
              "vendor": "Ubuntu",
              "versions": [
                {
                  "lessThan": "2024.05-2ubuntu0.3",
                  "status": "affected",
                  "version": "2024.05",
                  "versionType": "dpkg"
                },
                {
                  "lessThan": "2024.02-2ubuntu0.3",
                  "status": "affected",
                  "version": "2024.02",
                  "versionType": "dpkg"
                }
              ]
            }
          ],
          "source": "security@ubuntu.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:202402*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AEEAC129-5714-416C-B689-09707A561451",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:202405:*:*:*:*:*:*:*",
                  "matchCriteriaId": "67420046-C0C1-4B20-9B5F-A1F4ED477798",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Ubuntu edk2 UEFI firmware packages accidentally allowed the UEFI Shell to be accessed in Secure Boot environments, possibly allowing bypass of Secure Boot constraints. Versions 2024.05-2ubuntu0.3 and 2024.02-2ubuntu0.3 disable the Shell. Some previous versions inserted a secure-boot-based decision to continue running inside the Shell itself, which is believed to be sufficient to enforce Secure Boot restrictions. This is an additional repair on top of the incomplete fix for CVE-2023-48733."
        },
        {
          "lang": "es",
          "value": "Los paquetes de firmware UEFI edk2 de Ubuntu permitieron accidentalmente el acceso al Shell UEFI en entornos con Secure Boot, lo que posiblemente permit\u00eda eludir las restricciones de Secure Boot. Las versiones 2024.05-2ubuntu0.3 y 2024.02-2ubuntu0.3 deshabilitan el Shell. Algunas versiones anteriores insertaron una decisi\u00f3n basada en Secure Boot para continuar ejecut\u00e1ndose dentro del propio Shell, lo que se cree que es suficiente para hacer cumplir las restricciones de Secure Boot. Esta es una reparaci\u00f3n adicional adem\u00e1s de la correcci\u00f3n incompleta para CVE-2023-48733."
        }
      ],
      "id": "CVE-2025-2486",
      "lastModified": "2026-10-18T20:10:00.110",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.0,
            "impactScore": 6.0,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "HIGH",
              "attackRequirements": "NONE",
              "attackVector": "LOCAL",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 3.7,
              "baseSeverity": "LOW",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "UNREPORTED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "HIGH",
              "subConfidentialityImpact": "HIGH",
              "subIntegrityImpact": "HIGH",
              "userInteraction": "ACTIVE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:A/VC:N/VI:H/VA:N/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "NONE",
              "vulnConfidentialityImpact": "NONE",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "security@ubuntu.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-2486",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-11-26T18:25:19.164474Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-11-26T18:15:48.357",
      "references": [
        {
          "source": "security@ubuntu.com",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://bugs.launchpad.net/ubuntu/+source/edk2/+bug/2101797"
        }
      ],
      "sourceIdentifier": "security@ubuntu.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-489"
            }
          ],
          "source": "security@ubuntu.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-49721

    Vulnerability from fkie_nvd - Published: 2024-02-14 22:15 - Updated: 2026-06-17 06:36

    {
      "affected": [
        {
          "affectedData": [
            {
              "packageName": "lxd",
              "platforms": [
                "Linux"
              ],
              "product": "LXD",
              "vendor": "Canonical Ltd.",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                }
              ]
            }
          ],
          "source": "security@ubuntu.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:canonical:lxd:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "lxd",
              "vendor": "canonical",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:canonical:lxd:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CCDFE8E4-47BD-40FE-93BB-FC5106157DDF",
                  "versionEndExcluding": "5.21.0",
                  "versionStartIncluding": "5.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:-:*:*:*:*:*:*",
                  "matchCriteriaId": "6CE995B2-F287-4E18-B840-6EC5171BBBA5",
                  "versionEndIncluding": "2023.11-8",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An insecure default to allow UEFI Shell in EDK2 was left enabled in LXD. This allows an OS-resident attacker to bypass Secure Boot."
        },
        {
          "lang": "es",
          "value": "Un valor predeterminado inseguro para permitir UEFI Shell en EDK2 se dej\u00f3 habilitado en LXD. Esto permite que un atacante residente en el sistema operativo omita el arranque seguro."
        }
      ],
      "id": "CVE-2023-49721",
      "lastModified": "2026-06-17T06:36:21.073",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.7,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 0.8,
            "impactScore": 5.9,
            "source": "security@ubuntu.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-49721",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-02-15T16:55:58.653539Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-02-14T22:15:47.530",
      "references": [
        {
          "source": "security@ubuntu.com",
          "tags": [
            "Issue Tracking"
          ],
          "url": "https://bugs.launchpad.net/ubuntu/+source/edk2/+bug/2040137"
        },
        {
          "source": "security@ubuntu.com",
          "tags": [
            "Issue Tracking"
          ],
          "url": "https://bugs.launchpad.net/ubuntu/+source/lxd/+bug/2040139"
        },
        {
          "source": "security@ubuntu.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-48733"
        },
        {
          "source": "security@ubuntu.com",
          "tags": [
            "Mailing List"
          ],
          "url": "https://www.openwall.com/lists/oss-security/2024/02/14/4"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking"
          ],
          "url": "https://bugs.launchpad.net/ubuntu/+source/edk2/+bug/2040137"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking"
          ],
          "url": "https://bugs.launchpad.net/ubuntu/+source/lxd/+bug/2040139"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-48733"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "https://www.openwall.com/lists/oss-security/2024/02/14/4"
        }
      ],
      "sourceIdentifier": "security@ubuntu.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-276"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-48733

    Vulnerability from fkie_nvd - Published: 2024-02-14 22:15 - Updated: 2026-06-17 06:34

    {
      "affected": [
        {
          "affectedData": [
            {
              "packageName": "edk2",
              "platforms": [
                "Linux"
              ],
              "product": "Ubuntu EDK II",
              "vendor": "Canonical Ltd.",
              "versions": [
                {
                  "lessThan": "2023.05-2ubuntu0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "security@ubuntu.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:canonical:lxd:5.0:candidate:*:*:*:*:*:*",
                  "matchCriteriaId": "3B09DDCF-2D2C-4670-BEDF-5C3574AE0595",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:canonical:lxd:5.21:candidate:*:*:*:*:*:*",
                  "matchCriteriaId": "0707C567-7592-4564-86C3-427B4883E491",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:canonical:lxd:5.21:edge:*:*:*:*:*:*",
                  "matchCriteriaId": "9E7C13D8-BD34-44CA-B66A-328FD0A99919",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:-:*:*:*:*:*:*",
                  "matchCriteriaId": "6CE995B2-F287-4E18-B840-6EC5171BBBA5",
                  "versionEndIncluding": "2023.11-8",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An insecure default to allow UEFI Shell in EDK2 was left enabled in Ubuntu\u0027s EDK2. This allows an OS-resident attacker to bypass Secure Boot."
        },
        {
          "lang": "es",
          "value": "Un valor predeterminado inseguro para permitir UEFI Shell en EDK2 se dej\u00f3 habilitado en EDK2 de Ubuntu. Esto permite que un atacante residente en el sistema operativo omita el arranque seguro."
        }
      ],
      "id": "CVE-2023-48733",
      "lastModified": "2026-06-17T06:34:51.493",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.7,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 0.8,
            "impactScore": 5.9,
            "source": "security@ubuntu.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-48733",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-02-15T16:17:59.516818Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-02-14T22:15:47.320",
      "references": [
        {
          "source": "security@ubuntu.com",
          "tags": [
            "Issue Tracking"
          ],
          "url": "https://bugs.launchpad.net/ubuntu/+source/edk2/+bug/2040137"
        },
        {
          "source": "security@ubuntu.com",
          "tags": [
            "Issue Tracking"
          ],
          "url": "https://bugs.launchpad.net/ubuntu/+source/lxd/+bug/2040139"
        },
        {
          "source": "security@ubuntu.com",
          "tags": [
            "Mailing List"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2024/06/msg00028.html"
        },
        {
          "source": "security@ubuntu.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-48733"
        },
        {
          "source": "security@ubuntu.com",
          "tags": [
            "Mailing List"
          ],
          "url": "https://www.openwall.com/lists/oss-security/2024/02/14/4"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking"
          ],
          "url": "https://bugs.launchpad.net/ubuntu/+source/edk2/+bug/2040137"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking"
          ],
          "url": "https://bugs.launchpad.net/ubuntu/+source/lxd/+bug/2040139"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2024/06/msg00028.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-48733"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "https://www.openwall.com/lists/oss-security/2024/02/14/4"
        }
      ],
      "sourceIdentifier": "security@ubuntu.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-1188"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-45237

    Vulnerability from fkie_nvd - Published: 2024-01-16 16:15 - Updated: 2026-06-17 06:28

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202308"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2\u0027s Network Package is susceptible to a predictable TCP Initial Sequence Number. This\n vulnerability can be exploited by an attacker to gain unauthorized \naccess and potentially lead to a loss of Confidentiality."
        },
        {
          "lang": "es",
          "value": "EDK2\u0027s Network Package es susceptible a Initial Sequence Number TCP predecible. Un atacante puede aprovechar esta vulnerabilidad para obtener acceso no autorizado y potencialmente provocar una p\u00e9rdida de confidencialidad."
        }
      ],
      "id": "CVE-2023-45237",
      "lastModified": "2026-06-17T06:28:30.600",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-45237",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-11-13T19:58:00.747301Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-16T16:15:13.013",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.kb.cert.org/vuls/id/132380"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-338"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-338"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-45236

    Vulnerability from fkie_nvd - Published: 2024-01-16 16:15 - Updated: 2026-06-17 06:28

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202308"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2\u0027s Network Package is susceptible to a predictable TCP Initial Sequence Number. This\n vulnerability can be exploited by an attacker to gain unauthorized \naccess and potentially lead to a loss of Confidentiality."
        },
        {
          "lang": "es",
          "value": "EDK2\u0027s Network Package es susceptible a Initial Sequence Number TCP predecible. Un atacante puede aprovechar esta vulnerabilidad para obtener acceso no autorizado y potencialmente provocar una p\u00e9rdida de confidencialidad."
        }
      ],
      "id": "CVE-2023-45236",
      "lastModified": "2026-06-17T06:28:30.453",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-45236",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-08T15:43:01.945966Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-16T16:15:12.820",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.kb.cert.org/vuls/id/132380"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-200"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-338"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-45235

    Vulnerability from fkie_nvd - Published: 2024-01-16 16:15 - Updated: 2026-06-17 06:28
    Summary
    EDK2's Network Package is susceptible to a buffer overflow vulnerability when handling Server ID option from a DHCPv6 proxy Advertise message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality, Integrity and/or Availability.
    Impacted products
    Vendor Product Version
    tianocore edk2 *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202308"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2\u0027s Network Package is susceptible to a buffer overflow vulnerability when\n\n\n\n\n\nhandling Server ID option \n\n\n\n from a DHCPv6 proxy Advertise message. This\n vulnerability can be exploited by an attacker to gain unauthorized \naccess and potentially lead to a loss of Confidentiality, Integrity and/or Availability."
        },
        {
          "lang": "es",
          "value": "EDK2\u0027s Network Package es susceptible a una vulnerabilidad de desbordamiento de b\u00fafer cuando maneja la opci\u00f3n de ID del servidor desde un mensaje de publicidad del proxy DHCPv6. Un atacante puede aprovechar esta vulnerabilidad para obtener acceso no autorizado y potencialmente provocar una p\u00e9rdida de confidencialidad, integridad y/o disponibilidad."
        }
      ],
      "id": "CVE-2023-45235",
      "lastModified": "2026-06-17T06:28:30.310",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.3,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.5,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-45235",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-01-20T05:00:24.446605Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-16T16:15:12.643",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.kb.cert.org/vuls/id/132380"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-45234

    Vulnerability from fkie_nvd - Published: 2024-01-16 16:15 - Updated: 2026-06-17 06:28
    Summary
    EDK2's Network Package is susceptible to a buffer overflow vulnerability when processing DNS Servers option from a DHCPv6 Advertise message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality, Integrity and/or Availability.
    Impacted products
    Vendor Product Version
    tianocore edk2 *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202308"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2\u0027s Network Package is susceptible to a buffer overflow vulnerability when processing DNS Servers option from a DHCPv6 Advertise message. This\n vulnerability can be exploited by an attacker to gain unauthorized \naccess and potentially lead to a loss of Confidentiality, Integrity and/or Availability."
        },
        {
          "lang": "es",
          "value": "EDK2\u0027s Network Package es susceptible a una vulnerabilidad de desbordamiento de b\u00fafer al procesar la opci\u00f3n de servidores DNS desde un mensaje de publicidad DHCPv6. Un atacante puede aprovechar esta vulnerabilidad para obtener acceso no autorizado y potencialmente provocar una p\u00e9rdida de confidencialidad, integridad y/o disponibilidad."
        }
      ],
      "id": "CVE-2023-45234",
      "lastModified": "2026-06-17T06:28:30.170",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.3,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.5,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-45234",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-06-17T20:09:26.371967Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-16T16:15:12.460",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.kb.cert.org/vuls/id/132380"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-45233

    Vulnerability from fkie_nvd - Published: 2024-01-16 16:15 - Updated: 2026-06-17 06:28
    Summary
    EDK2's Network Package is susceptible to an infinite lop vulnerability when parsing a PadN option in the Destination Options header of IPv6. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Availability.
    Impacted products
    Vendor Product Version
    tianocore edk2 *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202308"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2\u0027s Network Package is susceptible to an infinite lop vulnerability when parsing a PadN option in the Destination Options header of IPv6. This\n vulnerability can be exploited by an attacker to gain unauthorized \naccess and potentially lead to a loss of Availability."
        },
        {
          "lang": "es",
          "value": "EDK2\u0027s Network Package es susceptible a una vulnerabilidad de bucle infinito al analizar una opci\u00f3n PadN en el encabezado Destination Options de IPv6. Un atacante puede aprovechar esta vulnerabilidad para obtener acceso no autorizado y potencialmente provocar una p\u00e9rdida de disponibilidad."
        }
      ],
      "id": "CVE-2023-45233",
      "lastModified": "2026-06-17T06:28:30.030",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-45233",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-01-20T05:00:22.954532Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-16T16:15:12.277",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.kb.cert.org/vuls/id/132380"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-835"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-835"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-45232

    Vulnerability from fkie_nvd - Published: 2024-01-16 16:15 - Updated: 2026-06-17 06:28
    Summary
    EDK2's Network Package is susceptible to an infinite loop vulnerability when parsing unknown options in the Destination Options header of IPv6. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Availability.
    Impacted products
    Vendor Product Version
    tianocore edk2 *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202308"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2\u0027s Network Package is susceptible to an infinite loop vulnerability when parsing unknown options in the Destination Options header of IPv6. This\n vulnerability can be exploited by an attacker to gain unauthorized \naccess and potentially lead to a loss of Availability."
        },
        {
          "lang": "es",
          "value": "EDK2\u0027s Network Package es susceptible a una vulnerabilidad de bucle infinito al analizar opciones desconocidas en el encabezado Destination Options de IPv6. Un atacante puede aprovechar esta vulnerabilidad para obtener acceso no autorizado y potencialmente provocar una p\u00e9rdida de disponibilidad."
        }
      ],
      "id": "CVE-2023-45232",
      "lastModified": "2026-06-17T06:28:29.900",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-45232",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-08T18:43:28.931722Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-16T16:15:12.090",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.kb.cert.org/vuls/id/132380"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-835"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-835"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-45231

    Vulnerability from fkie_nvd - Published: 2024-01-16 16:15 - Updated: 2026-06-17 06:28
    Summary
    EDK2's Network Package is susceptible to an out-of-bounds read vulnerability when processing  Neighbor Discovery Redirect message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality.
    Impacted products
    Vendor Product Version
    tianocore edk2 *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202308"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2\u0027s Network Package is susceptible to an out-of-bounds read\n vulnerability when processing\u00a0 Neighbor Discovery Redirect message. This\n vulnerability can be exploited by an attacker to gain unauthorized \naccess and potentially lead to a loss of Confidentiality."
        },
        {
          "lang": "es",
          "value": "El paquete de red de EDK2 es susceptible a una vulnerabilidad de lectura fuera de los l\u00edmites al procesar el mensaje de redirecci\u00f3n de descubrimiento de vecinos. Un atacante puede aprovechar esta vulnerabilidad para obtener acceso no autorizado y potencialmente provocar una p\u00e9rdida de confidencialidad."
        }
      ],
      "id": "CVE-2023-45231",
      "lastModified": "2026-06-17T06:28:29.763",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-45231",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-08-30T18:59:05.991713Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-16T16:15:11.910",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.kb.cert.org/vuls/id/132380"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-45230

    Vulnerability from fkie_nvd - Published: 2024-01-16 16:15 - Updated: 2026-06-17 06:28
    Summary
    EDK2's Network Package is susceptible to a buffer overflow vulnerability via a long server ID option in DHCPv6 client. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality, Integrity and/or Availability.
    Impacted products
    Vendor Product Version
    tianocore edk2 *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202308"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:tianocore:edk2:-:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "edk2",
              "vendor": "tianocore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202308"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2\u0027s Network Package is susceptible to a buffer overflow vulnerability via a long server ID option in DHCPv6 client. This\n vulnerability can be exploited by an attacker to gain unauthorized \naccess and potentially lead to a loss of Confidentiality, Integrity and/or Availability."
        },
        {
          "lang": "es",
          "value": "EDK2\u0027s Network Package es susceptible a una vulnerabilidad de desbordamiento de b\u00fafer a trav\u00e9s de una opci\u00f3n de ID de servidor larga en el cliente DHCPv6. Un atacante puede aprovechar esta vulnerabilidad para obtener acceso no autorizado y potencialmente provocar una p\u00e9rdida de confidencialidad, integridad y/o disponibilidad."
        }
      ],
      "id": "CVE-2023-45230",
      "lastModified": "2026-06-17T06:28:29.617",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.3,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.5,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-45230",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-07T20:15:22.589498Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-16T16:15:11.727",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.kb.cert.org/vuls/id/132380"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-45229

    Vulnerability from fkie_nvd - Published: 2024-01-16 16:15 - Updated: 2026-06-17 06:28
    Summary
    EDK2's Network Package is susceptible to an out-of-bounds read vulnerability when processing the IA_NA or IA_TA option in a DHCPv6 Advertise message. This vulnerability can be exploited by an attacker to gain unauthorized access and potentially lead to a loss of Confidentiality.
    Impacted products
    Vendor Product Version
    tianocore edk2 *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202308"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2\u0027s Network Package is susceptible to an out-of-bounds read\n vulnerability when processing the IA_NA or IA_TA option in a DHCPv6 Advertise message. This\n vulnerability can be exploited by an attacker to gain unauthorized \naccess and potentially lead to a loss of Confidentiality."
        },
        {
          "lang": "es",
          "value": "EDK2\u0027s Network Package es susceptible a una vulnerabilidad de lectura fuera de los l\u00edmites cuando procesa la opci\u00f3n IA_NA o IA_TA en un mensaje de publicidad DHCPv6. Un atacante puede aprovechar esta vulnerabilidad para obtener acceso no autorizado y potencialmente provocar una p\u00e9rdida de confidencialidad."
        }
      ],
      "id": "CVE-2023-45229",
      "lastModified": "2026-06-17T06:28:29.483",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-45229",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-08T15:54:42.873493Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-16T16:15:11.533",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/176574/PixieFail-Proof-Of-Concepts.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2024/01/16/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-hc6x-cw6p-gj7h"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240307-0011/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.kb.cert.org/vuls/id/132380"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-36765

    Vulnerability from fkie_nvd - Published: 2024-01-09 16:15 - Updated: 2026-06-17 04:53

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "lessThanOrEqual": "202311",
                  "status": "affected",
                  "version": "*",
                  "versionType": "Stable"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2 is susceptible to a vulnerability in the CreateHob() function, allowing a user to trigger a integer overflow to buffer overflow via a local network. Successful exploitation of this vulnerability may result in a compromise of confidentiality, integrity, and/or availability."
        },
        {
          "lang": "es",
          "value": "EDK2 es susceptible a una vulnerabilidad en la funci\u00f3n CreateHob(), lo que permite a un usuario activar un desbordamiento de enteros para desbordar el b\u00fafer a trav\u00e9s de una red local. La explotaci\u00f3n exitosa de esta vulnerabilidad puede resultar en un compromiso de confidencialidad, integridad y/o disponibilidad."
        }
      ],
      "id": "CVE-2022-36765",
      "lastModified": "2026-06-17T04:53:56.573",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.0,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.1,
            "impactScore": 5.3,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-36765",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-08T15:56:33.385699Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-09T16:15:43.500",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-ch4w-v7m3-g8wx"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-ch4w-v7m3-g8wx"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-680"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-36764

    Vulnerability from fkie_nvd - Published: 2024-01-09 16:15 - Updated: 2026-06-17 04:53

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "lessThanOrEqual": "202311",
                  "status": "affected",
                  "version": "*",
                  "versionType": "Stable"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2 is susceptible to a vulnerability in the Tcg2MeasurePeImage() function, allowing a user to trigger a heap buffer overflow via a local network. Successful exploitation of this vulnerability may result in a compromise of confidentiality, integrity, and/or availability."
        },
        {
          "lang": "es",
          "value": "EDK2 es susceptible a una vulnerabilidad en la funci\u00f3n Tcg2MeasurePeImage(), lo que permite a un usuario desencadenar un desbordamiento de b\u00fafer de almacenamiento din\u00e1mico a trav\u00e9s de una red local. La explotaci\u00f3n exitosa de esta vulnerabilidad puede resultar en un compromiso de confidencialidad, integridad y/o disponibilidad."
        }
      ],
      "id": "CVE-2022-36764",
      "lastModified": "2026-06-17T04:53:56.460",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.0,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.1,
            "impactScore": 5.3,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-36764",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-03-06T21:12:01.620840Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-09T16:15:43.327",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-4hcq-p8q8-hj8j"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-4hcq-p8q8-hj8j"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-122"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-36763

    Vulnerability from fkie_nvd - Published: 2024-01-09 16:15 - Updated: 2026-06-17 04:53

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "edk2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "lessThanOrEqual": "202311",
                  "status": "affected",
                  "version": "*",
                  "versionType": "Stable"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3CEB3105-57CC-4096-81D3-D58005813C4B",
                  "versionEndIncluding": "202311",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "EDK2 is susceptible to a vulnerability in the Tcg2MeasureGptTable() function, allowing a user to trigger a heap buffer overflow via a local network. Successful exploitation of this vulnerability may result in a compromise of confidentiality, integrity, and/or availability."
        },
        {
          "lang": "es",
          "value": "EDK2 es susceptible a una vulnerabilidad en la funci\u00f3n Tcg2MeasureGptTable(), lo que permite a un usuario desencadenar un desbordamiento de b\u00fafer de almacenamiento din\u00e1mico a trav\u00e9s de una red local. La explotaci\u00f3n exitosa de esta vulnerabilidad puede resultar en un compromiso de confidencialidad, integridad y/o disponibilidad."
        }
      ],
      "id": "CVE-2022-36763",
      "lastModified": "2026-06-17T04:53:56.340",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.0,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.1,
            "impactScore": 5.3,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-36763",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-08T19:10:15.558775Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-09T16:15:43.053",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Mitigation",
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-xvv8-66cq-prwr"
        },
        {
          "source": "infosec@edk2.groups.io",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mitigation",
            "Vendor Advisory"
          ],
          "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-xvv8-66cq-prwr"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SJ42V7O7F4OU6R7QSQQECLB6LDHKZIMQ/"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-122"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-38578

    Vulnerability from fkie_nvd - Published: 2022-03-03 22:15 - Updated: 2026-06-17 04:02

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "EDK II",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202208"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A2B1E98B-2D63-42E3-B6F8-139CC32BA4B0",
                  "versionEndIncluding": "202202",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFCC4619-B867-4E23-AF05-FF92B43628AF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FB40061A-BEDF-4D72-BF2D-D1B10EB80A60",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9D6AFE61-A2A4-49DF-A8EE-B2F425DA7A08",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.3:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D21132C0-F2CF-4134-A165-926155031913",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.4:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6549F7F1-A438-4C84-9D66-C89C697E2A9B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.5:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DE339FA1-8572-4365-B420-530D62686C08",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Existing CommBuffer checks in SmmEntryPoint will not catch underflow when computing BufferSize."
        },
        {
          "lang": "es",
          "value": "Unas comprobaciones existentes de CommBuffer en SmmEntryPoint no detectan el desbordamiento cuando es calculado BufferSize"
        }
      ],
      "id": "CVE-2021-38578",
      "lastModified": "2026-06-17T04:02:23.777",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "LOCAL",
              "availabilityImpact": "LOW",
              "baseScore": 7.4,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 0.8,
            "impactScore": 6.0,
            "source": "infosec@edk2.groups.io",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-38578",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-04-23T13:13:33.412696Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-03-03T22:15:08.423",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Issue Tracking",
            "Vendor Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=3387"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.insyde.com/security-pledge/SA-2023024"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking",
            "Vendor Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=3387"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.insyde.com/security-pledge/SA-2023024"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-124"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-38576

    Vulnerability from fkie_nvd - Published: 2022-01-03 22:15 - Updated: 2026-06-17 04:02
    Summary
    A BIOS bug in firmware for a particular PC model leaves the Platform authorization value empty. This can be used to permanently brick the TPM in multiple ways, as well as to non-permanently DoS the system.
    Impacted products
    Vendor Product Version
    tianocore edk2 201808
    tianocore edk2 201811
    tianocore edk2 201903
    tianocore edk2 201905
    tianocore edk2 201908
    tianocore edk2 201911
    tianocore edk2 202002
    tianocore edk2 202005
    tianocore edk2 202008
    tianocore edk2 202011
    tianocore edk2 202102
    tianocore edk2 202105

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "EDK II",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202105, edk2-stable202102, edk2-stable202011, edk2-stable202008, edk2-stable202005, edk2-stable202002, edk2-stable201911, edk2-stable201908, edk2-stable201905, edk2-stable201903, edk2-stable201811, edk2-stable201808"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:201808:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8757385B-6944-488F-B565-417A37C24774",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:201811:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E5C29B4B-635D-498E-BFA0-C99810C7867F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:201903:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A599E9E7-B318-4C66-A2F8-6137DE9EF8AC",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:201905:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5A3F577A-A397-4185-B477-C31065B6F598",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:201908:*:*:*:*:*:*:*",
                  "matchCriteriaId": "76E6EC0C-BA9E-47AD-9A8E-D40BE97CAAFA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:201911:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B2AFB7F1-63CF-4E11-8FD5-1E8D054616CF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:202002:*:*:*:*:*:*:*",
                  "matchCriteriaId": "02217318-D1DB-41BB-BE48-89BC3F0FA38C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:202005:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5193EFCE-3330-48FA-8C63-4CE328A2D339",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:202008:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1C45BEB6-1F89-4813-B2CF-90639F9CE525",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:202011:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C76CE4FB-3BDE-464B-9807-093839D6DB24",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:202102:*:*:*:*:*:*:*",
                  "matchCriteriaId": "063761E2-5C4D-480F-90FE-41D5ECC35E94",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:202105:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07F01519-D5C8-4BEE-A89B-8090F9A415CF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A BIOS bug in firmware for a particular PC model leaves the Platform authorization value empty. This can be used to permanently brick the TPM in multiple ways, as well as to non-permanently DoS the system."
        },
        {
          "lang": "es",
          "value": "Un error de la BIOS en el firmware de un determinado modelo de PC deja vac\u00edo el valor de autorizaci\u00f3n de la plataforma. Esto puede ser usado para brickear permanentemente el TPM de m\u00faltiples maneras, as\u00ed como para DoS no permanente del sistema"
        }
      ],
      "id": "CVE-2021-38576",
      "lastModified": "2026-06-17T04:02:23.653",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 7.8,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-01-03T22:15:09.903",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Issue Tracking",
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=3499"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking",
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=3499"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-38575

    Vulnerability from fkie_nvd - Published: 2021-12-01 18:15 - Updated: 2026-06-17 04:02

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "EDK II",
              "vendor": "TianoCore",
              "versions": [
                {
                  "lessThanOrEqual": "edk2-stable202105",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D81E5FE6-D7EC-49DA-BB6A-E58F9D7D3FBB",
                  "versionEndIncluding": "202105",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFCC4619-B867-4E23-AF05-FF92B43628AF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FB40061A-BEDF-4D72-BF2D-D1B10EB80A60",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9D6AFE61-A2A4-49DF-A8EE-B2F425DA7A08",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.3:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D21132C0-F2CF-4134-A165-926155031913",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.4:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6549F7F1-A438-4C84-9D66-C89C697E2A9B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:insyde:kernel:5.5:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DE339FA1-8572-4365-B420-530D62686C08",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "NetworkPkg/IScsiDxe has remotely exploitable buffer overflows."
        },
        {
          "lang": "es",
          "value": "NetworkPkg/IScsiDxe presenta unos desbordamientos de b\u00fafer explotables de forma remota"
        }
      ],
      "id": "CVE-2021-38575",
      "lastModified": "2026-06-17T04:02:23.547",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-12-01T18:15:07.760",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Exploit",
            "Issue Tracking",
            "Vendor Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=3356"
        },
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.insyde.com/security-pledge/SA-2023025"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Issue Tracking",
            "Vendor Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=3356"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2025/06/msg00007.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.insyde.com/security-pledge/SA-2023025"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-124"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-28213

    Vulnerability from fkie_nvd - Published: 2021-06-11 16:15 - Updated: 2026-06-17 03:46
    Summary
    Example EDK2 encrypted private key in the IpSecDxe.efi present potential security risks.
    References
    infosec@edk2.groups.iohttps://bugzilla.tianocore.org/show_bug.cgi?id=1866Issue Tracking, Permissions Required, Vendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://bugzilla.tianocore.org/show_bug.cgi?id=1866Issue Tracking, Permissions Required, Vendor Advisory
    Impacted products
    Vendor Product Version
    tianocore edk2 201905

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "EDK II",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable201905"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:201905:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5A3F577A-A397-4185-B477-C31065B6F598",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Example EDK2 encrypted private key in the IpSecDxe.efi present potential security risks."
        },
        {
          "lang": "es",
          "value": "La clave privada cifrada Example EDK2 en el archivo IpSecDxe.efi presenta riesgos potenciales de seguridad"
        }
      ],
      "id": "CVE-2021-28213",
      "lastModified": "2026-06-17T03:46:04.687",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-06-11T16:15:12.570",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Issue Tracking",
            "Permissions Required",
            "Vendor Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=1866"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking",
            "Permissions Required",
            "Vendor Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=1866"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-28211

    Vulnerability from fkie_nvd - Published: 2021-06-11 16:15 - Updated: 2026-06-17 03:46
    Summary
    A heap overflow in LzmaUefiDecompressGetInfo function in EDK II.
    References
    Impacted products
    Vendor Product Version
    tianocore edk2 202008

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "EDK II",
              "vendor": "TianoCore",
              "versions": [
                {
                  "status": "affected",
                  "version": "edk2-stable202008"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:202008:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1C45BEB6-1F89-4813-B2CF-90639F9CE525",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A heap overflow in LzmaUefiDecompressGetInfo function in EDK II."
        },
        {
          "lang": "es",
          "value": "Un desbordamiento de la pila en la funci\u00f3n zmaUefiDecompressGetInfo en EDK II"
        }
      ],
      "id": "CVE-2021-28211",
      "lastModified": "2026-06-17T03:46:04.583",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.6,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.7,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 0.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-06-11T16:15:12.503",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Exploit",
            "Issue Tracking",
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=1816"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Issue Tracking",
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=1816"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-122"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-28210

    Vulnerability from fkie_nvd - Published: 2021-06-11 16:15 - Updated: 2026-06-17 03:46
    Summary
    An unlimited recursion in DxeCore in EDK II.
    References
    Impacted products
    Vendor Product Version
    tianocore edk2 *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "EDK II",
              "vendor": "TianoCore",
              "versions": [
                {
                  "lessThanOrEqual": "edk2-stable202008",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "infosec@edk2.groups.io"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F0242CC2-68D7-42BA-9163-7F40AACA65CF",
                  "versionEndExcluding": "202008",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An unlimited recursion in DxeCore in EDK II."
        },
        {
          "lang": "es",
          "value": "Una recursi\u00f3n ilimitada en la funci\u00f3n DxeCore en EDK II"
        }
      ],
      "id": "CVE-2021-28210",
      "lastModified": "2026-06-17T03:46:04.467",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.6,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-06-11T16:15:12.430",
      "references": [
        {
          "source": "infosec@edk2.groups.io",
          "tags": [
            "Exploit",
            "Issue Tracking",
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=1743"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Issue Tracking",
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=1743"
        }
      ],
      "sourceIdentifier": "infosec@edk2.groups.io",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-674"
            }
          ],
          "source": "infosec@edk2.groups.io",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-674"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2026-18448 (GCVE-0-2026-18448)

    Vulnerability from nvd – Published: 2026-11-10 18:39 – Updated: 2026-11-16 18:26
    VLAI
    Title
    Leak SMM RAM from the kernel (Simply TSA after an SMI)
    Summary
    EDK2 contains a vulnerability in BIOS where a privileged attacker may cause “Exposure of Sensitive Information during Transient Execution” by local access. Successful exploitation of this vulnerability may result in disclosure of SMRAM contents. It could also impact Confidentiality.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-16 18:25 UTC
    CWE
    • CWE-1420 - Exposure of Sensitive Information during Transient Execution
    Assigner
    TianoCore CNA under the mitre root
    CNA scorecard – unranked: 3 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    TianoCore EDK2 Affected: 0 , ≤ edk2-stable202608 (custom)
    Create a notification for this product.
    Date Public
    2026-11-10 18:38
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-18448",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-16T18:25:55.113224Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-16T18:26:52.944Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EDK2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "lessThanOrEqual": "edk2-stable202608",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Abdul Lateef Attar"
            }
          ],
          "datePublic": "2026-11-10T18:38:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eEDK2 contains a vulnerability in BIOS\nwhere a privileged attacker may cause \u201cExposure of Sensitive Information during\nTransient Execution\u201d by local access. Successful exploitation of\nthis vulnerability may result in disclosure of SMRAM contents. It could also impact Confidentiality.\u003c/p\u003e"
                }
              ],
              "value": "EDK2 contains a vulnerability in BIOS\nwhere a privileged attacker may cause \u201cExposure of Sensitive Information during\nTransient Execution\u201d by local access. Successful exploitation of\nthis vulnerability may result in disclosure of SMRAM contents. It could also impact Confidentiality."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1420",
                  "description": "CWE-1420 Exposure of Sensitive Information during Transient Execution",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-10T18:39:53.329Z",
            "orgId": "65518388-201a-4f93-8712-366d21fe8d2c",
            "shortName": "TianoCore"
          },
          "references": [
            {
              "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-7v86-66vf-h88j"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Leak SMM RAM from the kernel (Simply TSA after an SMI)",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "65518388-201a-4f93-8712-366d21fe8d2c",
        "assignerShortName": "TianoCore",
        "cveId": "CVE-2026-18448",
        "datePublished": "2026-11-10T18:39:53.329Z",
        "dateReserved": "2026-07-31T04:04:58.388Z",
        "dateUpdated": "2026-11-16T18:26:52.944Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-14968 (GCVE-0-2026-14968)

    Vulnerability from nvd – Published: 2026-11-10 18:50 – Updated: 2026-11-16 18:30
    VLAI
    Title
    AMD MmSaveStateLib SysCall path performs out-of-bounds writes for partial save-state reads
    Summary
    EDK2 contains vulnerabilities in BIOS where skilled and privileged users or attackers may cause “Out-of-bounds Write” by local access. Successful exploitation of this vulnerability could compromise SMM handler integrity, cause system instability, and lead to denial of service. It could also impact Integrity and Availability.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-16 18:29 UTC
    CWE
    Assigner
    TianoCore CNA under the mitre root
    CNA scorecard – unranked: 3 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    TianoCore EDK2 Affected: 0 , ≤ edk2-stable202608 (custom)
    Create a notification for this product.
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-14968",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-16T18:29:40.587810Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-16T18:30:31.486Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-979r-6wfh-gq4h"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EDK2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "lessThanOrEqual": "edk2-stable202608",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "20000419"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eEDK2 contains vulnerabilities in\nBIOS where skilled and privileged users or attackers may cause \u201cOut-of-bounds Write\u201d by local access. Successful exploitation of this vulnerability could compromise\nSMM handler integrity, cause system instability, and lead to denial of service. It could also impact Integrity and Availability.\u003c/p\u003e"
                }
              ],
              "value": "EDK2 contains vulnerabilities in\nBIOS where skilled and privileged users or attackers may cause \u201cOut-of-bounds Write\u201d by local access. Successful exploitation of this vulnerability could compromise\nSMM handler integrity, cause system instability, and lead to denial of service. It could also impact Integrity and Availability."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-10T18:50:37.286Z",
            "orgId": "65518388-201a-4f93-8712-366d21fe8d2c",
            "shortName": "TianoCore"
          },
          "references": [
            {
              "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-979r-6wfh-gq4h"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "AMD MmSaveStateLib SysCall path performs out-of-bounds writes for partial save-state reads",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "65518388-201a-4f93-8712-366d21fe8d2c",
        "assignerShortName": "TianoCore",
        "cveId": "CVE-2026-14968",
        "datePublished": "2026-11-10T18:50:37.286Z",
        "dateReserved": "2026-07-07T15:14:21.318Z",
        "dateUpdated": "2026-11-16T18:30:31.486Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-97631 (GCVE-0-2026-97631)

    Vulnerability from nvd – Published: 2026-10-22 16:32 – Updated: 2026-10-30 19:34
    VLAI
    Title
    Pre-boot RCE in EDK II PXE driver
    Summary
    EDK2 contains a vulnerability in BIOS where a user may cause “Out-of-bounds Write”, Classic Buffer Overflow, and “Incorrect Calculation of Buffer Size” by remote access. Successful exploitation of this vulnerability can lead to arbitrary code execution. It could also impact Confidentiality, Integrity, and Availability.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-30 19:34 UTC
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    • CWE-131 - Incorrect calculation of buffer size
    • CWE-787 - Out-of-bounds write
    Assigner
    TianoCore CNA under the mitre root
    CNA scorecard – unranked: 3 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    TianoCore EDK2 Affected: 0 , ≤ edk2-stable202608 (custom)
    Create a notification for this product.
    Date Public
    2026-10-22 16:32
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2026-10-28T16:06:34.929Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://arstechnica.com/security/2026/10/code-execution-flaw-in-uefi-firmware-threatens-most-servers-on-planet-earth/"
              },
              {
                "url": "https://news.ycombinator.com/item?id=50265393"
              },
              {
                "url": "https://github.com/microsoft/mu_basecore/pull/1990"
              },
              {
                "url": "https://github.com/microsoft/mu_basecore/pull/1989"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/28/4"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-97631",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-30T19:34:29.002368Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-30T19:34:40.851Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "NetworkPkg",
              "product": "EDK2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "lessThanOrEqual": "edk2-stable202608",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alex Matrosov (Anthropic)"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Dan Holmes-Mitra (Google)"
            }
          ],
          "datePublic": "2026-10-22T16:32:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eEDK2 contains a vulnerability in BIOS where a user may cause \u201cOut-of-bounds\nWrite\u201d, Classic\nBuffer Overflow, and \u201cIncorrect Calculation of Buffer Size\u201d by remote access. Successful exploitation of this vulnerability\ncan lead to arbitrary\ncode execution. It could also impact\nConfidentiality,\nIntegrity,\nand Availability.\u003c/p\u003e"
                }
              ],
              "value": "EDK2 contains a vulnerability in BIOS where a user may cause \u201cOut-of-bounds\nWrite\u201d, Classic\nBuffer Overflow, and \u201cIncorrect Calculation of Buffer Size\u201d by remote access. Successful exploitation of this vulnerability\ncan lead to arbitrary\ncode execution. It could also impact\nConfidentiality,\nIntegrity,\nand Availability."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.5,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-131",
                  "description": "CWE-131 Incorrect calculation of buffer size",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-22T16:37:13.437Z",
            "orgId": "65518388-201a-4f93-8712-366d21fe8d2c",
            "shortName": "TianoCore"
          },
          "references": [
            {
              "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-99cj-7hg9-mp4m"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Pre-boot RCE in EDK II PXE driver",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "65518388-201a-4f93-8712-366d21fe8d2c",
        "assignerShortName": "TianoCore",
        "cveId": "CVE-2026-97631",
        "datePublished": "2026-10-22T16:32:27.619Z",
        "dateReserved": "2026-09-24T16:56:45.359Z",
        "dateUpdated": "2026-10-30T19:34:40.851Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-111497 (GCVE-0-2026-111497)

    Vulnerability from nvd – Published: 2026-10-22 13:35 – Updated: 2026-11-24 14:26
    VLAI CISA Previdian
    Title
    Out-of-Bounds Write in Google Brotli Decoder
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-23 00:00 UTC
    CWE
    Assigner
    Google CNA under the Google root
    CNA scorecard B 78/100 over 37 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Google Brotli Affected: 1.0.3 , < 1.0.10 (semver)
    Affected: 1.1.0 , < 1.1.1 (semver)
    Affected: 1.2.0 , < 1.2.1 (semver)
    Create a notification for this product.
    Siemens blueplanet 100 NX3 M8 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 125 NX3 M10 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 87.0 TL3 – 165 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 100 – 165 TL3 (HV) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 92 – 137 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens COMOS Walkinside Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens gDAP (gPROMS Digital Application Platform) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Gridscale X DSA Affected: V5.3 , < V5.4 (custom)
    Create a notification for this product.
    Siemens Gridscale X PSS®E Affected: 0 , < V36.8.0 (custom)
    Create a notification for this product.
    Siemens Heliox Dual Port 60kW Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Integrated PA Suite Tester Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens INTRALOG WMS Kronos Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Project Server Web Administration Tool Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE LPE9403 (6GK5998-3GS00-2AC2) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE LPE9413 (6GK5998-3GS01-2AC2) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE LPE9423 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE LPE9433 (6GK5998-3GS11-2AC2) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICAM PAS CC Affected: V6.02 , < * (custom)
    Create a notification for this product.
    Siemens SICAM SCC Affected: V7.01 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE FLEX Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE UC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Go Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Setup Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC BRAUMAT Affected: V8.2 Update 1 , < V8.2 Update 5 (custom)
    Create a notification for this product.
    Siemens SIMATIC PCS neo Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC Profiling Tool Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC SISTAR Affected: V8.2 Update 1 , < V8.2 Update 5 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Companion Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.20 Affected: 0 , < V3.20.17.1 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.21 Affected: 0 , < V3.21.7 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified for Industrial Edge Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified PC Runtime Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified SIQENCE Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC V7/V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SINEC INS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SINEMA Remote Connect Client Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SINEMA Remote Connect Edge Client Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SITOP Manager Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens TIA Administrator Affected: 0 , < V3.3.1 (custom)
    Create a notification for this product.
    Siemens User Management Component (UMC) Affected: 0 , < V2.15.4.1 (custom)
    Create a notification for this product.
    Siemens VersiCharge AC Series Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCloud Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Cloud Connector Configurator Affected: 0 , < V1.24.3 (custom)
    Create a notification for this product.

    50 of 87 products shown. All of them on the page of CVE-2026-111497.

    Date Public
    2026-02-27 07:50
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-111497",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-23T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:48.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-03T21:05:46.791Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
              },
              {
                "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
              },
              {
                "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
              },
              {
                "url": "https://broccoli2shell.com"
              },
              {
                "url": "https://github.com/dotnet/announcements/issues/494"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
              },
              {
                "url": "https://patchtheplanet.org/brotli"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 125 NX3 M10",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "COMOS Walkinside",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "gDAP (gPROMS Digital Application Platform)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X DSA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.4",
                    "status": "affected",
                    "version": "V5.3",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X PSS\u00aeE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V36.8.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Integrated PA Suite Tester",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "INTRALOG WMS Kronos",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "INTRALOG WMS Kronos",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Project Server Web Administration Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE LPE9403 (6GK5998-3GS00-2AC2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE LPE9413 (6GK5998-3GS01-2AC2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE LPE9423",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE LPE9433 (6GK5998-3GS11-2AC2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM PAS CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V6.02",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM SCC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V7.01",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC BRAUMAT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS neo",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Profiling Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC SISTAR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Companion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.20",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.20.17.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.21",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.21.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Runtime Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified for Industrial Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified PC Runtime",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified SIQENCE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7/V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEC INS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEMA Remote Connect Client",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEMA Remote Connect Edge Client",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SITOP Manager",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Administrator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "User Management Component (UMC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.4.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCharge AC Series",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Cloud Connector Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.24.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator\u00a0(CC on IEM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator on Device\u00a0(CC on Edge)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Data Flow Monitoring",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.18",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Databus Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DataXess Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.5.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Edge OPC UA Server Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Flow Creator Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Management Cloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Innexis Architecture Native Acceleration 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PAVE360 Automotive 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Process Preparation X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Executable Digital Twin",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Studio",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2412",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2506",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2512",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2606",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-24T14:26:40.717Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
            }
          ],
          "datePublic": "2026-02-27T07:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-27T14:58:42.704Z",
            "orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
            "shortName": "Google"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
            },
            {
              "tags": [
                "release-notes",
                "third-party-advisory"
              ],
              "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
                }
              ],
              "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Out-of-Bounds Write in Google Brotli Decoder",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
        "assignerShortName": "Google",
        "cveId": "CVE-2026-111497",
        "datePublished": "2026-10-22T13:35:41.975Z",
        "dateReserved": "2026-10-16T09:58:17.790Z",
        "dateUpdated": "2026-11-24T14:26:40.717Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-14968 (GCVE-0-2026-14968)

    Vulnerability from cvelistv5 – Published: 2026-11-10 18:50 – Updated: 2026-11-16 18:30
    VLAI
    Title
    AMD MmSaveStateLib SysCall path performs out-of-bounds writes for partial save-state reads
    Summary
    EDK2 contains vulnerabilities in BIOS where skilled and privileged users or attackers may cause “Out-of-bounds Write” by local access. Successful exploitation of this vulnerability could compromise SMM handler integrity, cause system instability, and lead to denial of service. It could also impact Integrity and Availability.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-16 18:29 UTC
    CWE
    Assigner
    TianoCore CNA under the mitre root
    CNA scorecard – unranked: 3 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    TianoCore EDK2 Affected: 0 , ≤ edk2-stable202608 (custom)
    Create a notification for this product.
    Credits
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-14968",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-16T18:29:40.587810Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-16T18:30:31.486Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-979r-6wfh-gq4h"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EDK2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "lessThanOrEqual": "edk2-stable202608",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "20000419"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eEDK2 contains vulnerabilities in\nBIOS where skilled and privileged users or attackers may cause \u201cOut-of-bounds Write\u201d by local access. Successful exploitation of this vulnerability could compromise\nSMM handler integrity, cause system instability, and lead to denial of service. It could also impact Integrity and Availability.\u003c/p\u003e"
                }
              ],
              "value": "EDK2 contains vulnerabilities in\nBIOS where skilled and privileged users or attackers may cause \u201cOut-of-bounds Write\u201d by local access. Successful exploitation of this vulnerability could compromise\nSMM handler integrity, cause system instability, and lead to denial of service. It could also impact Integrity and Availability."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-10T18:50:37.286Z",
            "orgId": "65518388-201a-4f93-8712-366d21fe8d2c",
            "shortName": "TianoCore"
          },
          "references": [
            {
              "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-979r-6wfh-gq4h"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "AMD MmSaveStateLib SysCall path performs out-of-bounds writes for partial save-state reads",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "65518388-201a-4f93-8712-366d21fe8d2c",
        "assignerShortName": "TianoCore",
        "cveId": "CVE-2026-14968",
        "datePublished": "2026-11-10T18:50:37.286Z",
        "dateReserved": "2026-07-07T15:14:21.318Z",
        "dateUpdated": "2026-11-16T18:30:31.486Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-18448 (GCVE-0-2026-18448)

    Vulnerability from cvelistv5 – Published: 2026-11-10 18:39 – Updated: 2026-11-16 18:26
    VLAI
    Title
    Leak SMM RAM from the kernel (Simply TSA after an SMI)
    Summary
    EDK2 contains a vulnerability in BIOS where a privileged attacker may cause “Exposure of Sensitive Information during Transient Execution” by local access. Successful exploitation of this vulnerability may result in disclosure of SMRAM contents. It could also impact Confidentiality.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-16 18:25 UTC
    CWE
    • CWE-1420 - Exposure of Sensitive Information during Transient Execution
    Assigner
    TianoCore CNA under the mitre root
    CNA scorecard – unranked: 3 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    TianoCore EDK2 Affected: 0 , ≤ edk2-stable202608 (custom)
    Create a notification for this product.
    Date Public
    2026-11-10 18:38
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-18448",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-16T18:25:55.113224Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-16T18:26:52.944Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EDK2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "lessThanOrEqual": "edk2-stable202608",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Abdul Lateef Attar"
            }
          ],
          "datePublic": "2026-11-10T18:38:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eEDK2 contains a vulnerability in BIOS\nwhere a privileged attacker may cause \u201cExposure of Sensitive Information during\nTransient Execution\u201d by local access. Successful exploitation of\nthis vulnerability may result in disclosure of SMRAM contents. It could also impact Confidentiality.\u003c/p\u003e"
                }
              ],
              "value": "EDK2 contains a vulnerability in BIOS\nwhere a privileged attacker may cause \u201cExposure of Sensitive Information during\nTransient Execution\u201d by local access. Successful exploitation of\nthis vulnerability may result in disclosure of SMRAM contents. It could also impact Confidentiality."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1420",
                  "description": "CWE-1420 Exposure of Sensitive Information during Transient Execution",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-10T18:39:53.329Z",
            "orgId": "65518388-201a-4f93-8712-366d21fe8d2c",
            "shortName": "TianoCore"
          },
          "references": [
            {
              "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-7v86-66vf-h88j"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Leak SMM RAM from the kernel (Simply TSA after an SMI)",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "65518388-201a-4f93-8712-366d21fe8d2c",
        "assignerShortName": "TianoCore",
        "cveId": "CVE-2026-18448",
        "datePublished": "2026-11-10T18:39:53.329Z",
        "dateReserved": "2026-07-31T04:04:58.388Z",
        "dateUpdated": "2026-11-16T18:26:52.944Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-97631 (GCVE-0-2026-97631)

    Vulnerability from cvelistv5 – Published: 2026-10-22 16:32 – Updated: 2026-10-30 19:34
    VLAI
    Title
    Pre-boot RCE in EDK II PXE driver
    Summary
    EDK2 contains a vulnerability in BIOS where a user may cause “Out-of-bounds Write”, Classic Buffer Overflow, and “Incorrect Calculation of Buffer Size” by remote access. Successful exploitation of this vulnerability can lead to arbitrary code execution. It could also impact Confidentiality, Integrity, and Availability.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-30 19:34 UTC
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    • CWE-131 - Incorrect calculation of buffer size
    • CWE-787 - Out-of-bounds write
    Assigner
    TianoCore CNA under the mitre root
    CNA scorecard – unranked: 3 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    TianoCore EDK2 Affected: 0 , ≤ edk2-stable202608 (custom)
    Create a notification for this product.
    Date Public
    2026-10-22 16:32
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2026-10-28T16:06:34.929Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://arstechnica.com/security/2026/10/code-execution-flaw-in-uefi-firmware-threatens-most-servers-on-planet-earth/"
              },
              {
                "url": "https://news.ycombinator.com/item?id=50265393"
              },
              {
                "url": "https://github.com/microsoft/mu_basecore/pull/1990"
              },
              {
                "url": "https://github.com/microsoft/mu_basecore/pull/1989"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/28/4"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-97631",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-30T19:34:29.002368Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-30T19:34:40.851Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "NetworkPkg",
              "product": "EDK2",
              "vendor": "TianoCore",
              "versions": [
                {
                  "lessThanOrEqual": "edk2-stable202608",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alex Matrosov (Anthropic)"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Dan Holmes-Mitra (Google)"
            }
          ],
          "datePublic": "2026-10-22T16:32:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eEDK2 contains a vulnerability in BIOS where a user may cause \u201cOut-of-bounds\nWrite\u201d, Classic\nBuffer Overflow, and \u201cIncorrect Calculation of Buffer Size\u201d by remote access. Successful exploitation of this vulnerability\ncan lead to arbitrary\ncode execution. It could also impact\nConfidentiality,\nIntegrity,\nand Availability.\u003c/p\u003e"
                }
              ],
              "value": "EDK2 contains a vulnerability in BIOS where a user may cause \u201cOut-of-bounds\nWrite\u201d, Classic\nBuffer Overflow, and \u201cIncorrect Calculation of Buffer Size\u201d by remote access. Successful exploitation of this vulnerability\ncan lead to arbitrary\ncode execution. It could also impact\nConfidentiality,\nIntegrity,\nand Availability."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.5,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-131",
                  "description": "CWE-131 Incorrect calculation of buffer size",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-22T16:37:13.437Z",
            "orgId": "65518388-201a-4f93-8712-366d21fe8d2c",
            "shortName": "TianoCore"
          },
          "references": [
            {
              "url": "https://github.com/tianocore/edk2/security/advisories/GHSA-99cj-7hg9-mp4m"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Pre-boot RCE in EDK II PXE driver",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "65518388-201a-4f93-8712-366d21fe8d2c",
        "assignerShortName": "TianoCore",
        "cveId": "CVE-2026-97631",
        "datePublished": "2026-10-22T16:32:27.619Z",
        "dateReserved": "2026-09-24T16:56:45.359Z",
        "dateUpdated": "2026-10-30T19:34:40.851Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-111497 (GCVE-0-2026-111497)

    Vulnerability from cvelistv5 – Published: 2026-10-22 13:35 – Updated: 2026-11-24 14:26
    VLAI CISA Previdian
    Title
    Out-of-Bounds Write in Google Brotli Decoder
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-23 00:00 UTC
    CWE
    Assigner
    Google CNA under the Google root
    CNA scorecard B 78/100 over 37 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Google Brotli Affected: 1.0.3 , < 1.0.10 (semver)
    Affected: 1.1.0 , < 1.1.1 (semver)
    Affected: 1.2.0 , < 1.2.1 (semver)
    Create a notification for this product.
    Siemens blueplanet 100 NX3 M8 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 125 NX3 M10 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 87.0 TL3 – 165 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 100 – 165 TL3 (HV) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 92 – 137 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens COMOS Walkinside Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens gDAP (gPROMS Digital Application Platform) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Gridscale X DSA Affected: V5.3 , < V5.4 (custom)
    Create a notification for this product.
    Siemens Gridscale X PSS®E Affected: 0 , < V36.8.0 (custom)
    Create a notification for this product.
    Siemens Heliox Dual Port 60kW Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Integrated PA Suite Tester Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens INTRALOG WMS Kronos Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Project Server Web Administration Tool Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE LPE9403 (6GK5998-3GS00-2AC2) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE LPE9413 (6GK5998-3GS01-2AC2) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE LPE9423 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SCALANCE LPE9433 (6GK5998-3GS11-2AC2) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICAM PAS CC Affected: V6.02 , < * (custom)
    Create a notification for this product.
    Siemens SICAM SCC Affected: V7.01 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE FLEX Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE UC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Go Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Setup Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC BRAUMAT Affected: V8.2 Update 1 , < V8.2 Update 5 (custom)
    Create a notification for this product.
    Siemens SIMATIC PCS neo Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC Profiling Tool Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC SISTAR Affected: V8.2 Update 1 , < V8.2 Update 5 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Companion Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.20 Affected: 0 , < V3.20.17.1 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.21 Affected: 0 , < V3.21.7 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified for Industrial Edge Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified PC Runtime Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC Unified SIQENCE Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC WinCC V7/V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SINEC INS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SINEMA Remote Connect Client Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SINEMA Remote Connect Edge Client Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SITOP Manager Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens TIA Administrator Affected: 0 , < V3.3.1 (custom)
    Create a notification for this product.
    Siemens User Management Component (UMC) Affected: 0 , < V2.15.4.1 (custom)
    Create a notification for this product.
    Siemens VersiCharge AC Series Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCloud Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Cloud Connector Configurator Affected: 0 , < V1.24.3 (custom)
    Create a notification for this product.

    50 of 87 products shown. All of them on the page of CVE-2026-111497.

    Date Public
    2026-02-27 07:50
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-111497",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-23T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:48.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-03T21:05:46.791Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
              },
              {
                "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
              },
              {
                "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
              },
              {
                "url": "https://broccoli2shell.com"
              },
              {
                "url": "https://github.com/dotnet/announcements/issues/494"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
              },
              {
                "url": "https://patchtheplanet.org/brotli"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 125 NX3 M10",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "COMOS Walkinside",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "gDAP (gPROMS Digital Application Platform)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X DSA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.4",
                    "status": "affected",
                    "version": "V5.3",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X PSS\u00aeE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V36.8.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Integrated PA Suite Tester",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "INTRALOG WMS Kronos",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "INTRALOG WMS Kronos",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Project Server Web Administration Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE LPE9403 (6GK5998-3GS00-2AC2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE LPE9413 (6GK5998-3GS01-2AC2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE LPE9423",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SCALANCE LPE9433 (6GK5998-3GS11-2AC2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM PAS CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V6.02",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM SCC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V7.01",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC BRAUMAT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PCS neo",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Profiling Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC SISTAR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Companion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.20",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.20.17.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.21",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.21.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Runtime Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified for Industrial Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified PC Runtime",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified SIQENCE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7/V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEC INS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEMA Remote Connect Client",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SINEMA Remote Connect Edge Client",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SITOP Manager",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Administrator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.3.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "User Management Component (UMC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.4.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCharge AC Series",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Cloud Connector Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.24.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator\u00a0(CC on IEM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator on Device\u00a0(CC on Edge)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Data Flow Monitoring",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.18",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Databus Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DataXess Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.5.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Edge OPC UA Server Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Flow Creator Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Management Cloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Innexis Architecture Native Acceleration 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PAVE360 Automotive 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Process Preparation X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Executable Digital Twin",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Studio",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2412",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2506",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2512",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2606",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-24T14:26:40.717Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
            }
          ],
          "datePublic": "2026-02-27T07:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-27T14:58:42.704Z",
            "orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
            "shortName": "Google"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
            },
            {
              "tags": [
                "release-notes",
                "third-party-advisory"
              ],
              "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
                }
              ],
              "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Out-of-Bounds Write in Google Brotli Decoder",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
        "assignerShortName": "Google",
        "cveId": "CVE-2026-111497",
        "datePublished": "2026-10-22T13:35:41.975Z",
        "dateReserved": "2026-10-16T09:58:17.790Z",
        "dateUpdated": "2026-11-24T14:26:40.717Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }