Search

Find a vulnerability

Search criteria

    56 vulnerabilities found for dialink by deltaww

    FKIE_CVE-2025-58321

    Vulnerability from fkie_nvd - Published: 2025-09-11 09:15 - Updated: 2026-10-18 21:10
    Summary
    Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.6.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "759f5e80-c8e1-4224-bead-956d7b33c98b"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "99A5C428-127C-4FB7-BFFA-CD8E0CB6B840",
                  "versionEndExcluding": "1.8.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
        },
        {
          "lang": "es",
          "value": "Delta Electronics DIALink tiene una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n por salto de directorio."
        }
      ],
      "id": "CVE-2025-58321",
      "lastModified": "2026-10-18T21:10:00.120",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 10.0,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.0,
            "source": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-58321",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-09-11T13:29:52.053857Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-09-11T09:15:35.010",
      "references": [
        {
          "source": "759f5e80-c8e1-4224-bead-956d7b33c98b",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00016_DIALink%20-%20Directory%20Traversal%20Authentication%20Bypass%20Vulnerability.pdf"
        }
      ],
      "sourceIdentifier": "759f5e80-c8e1-4224-bead-956d7b33c98b",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "759f5e80-c8e1-4224-bead-956d7b33c98b",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-58320

    Vulnerability from fkie_nvd - Published: 2025-09-11 09:15 - Updated: 2026-06-17 09:44
    Summary
    Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.6.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "759f5e80-c8e1-4224-bead-956d7b33c98b"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "99A5C428-127C-4FB7-BFFA-CD8E0CB6B840",
                  "versionEndExcluding": "1.8.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
        }
      ],
      "id": "CVE-2025-58320",
      "lastModified": "2026-06-17T09:44:17.723",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 7.3,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.4,
            "source": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 7.3,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-58320",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-09-11T13:29:29.552980Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-09-11T09:15:34.807",
      "references": [
        {
          "source": "759f5e80-c8e1-4224-bead-956d7b33c98b",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00016_DIALink%20-%20Directory%20Traversal%20Authentication%20Bypass%20Vulnerability.pdf"
        }
      ],
      "sourceIdentifier": "759f5e80-c8e1-4224-bead-956d7b33c98b",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "759f5e80-c8e1-4224-bead-956d7b33c98b",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2022-2969

    Vulnerability from fkie_nvd - Published: 2022-12-01 18:15 - Updated: 2026-06-17 04:42
    Summary
    Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.
    Impacted products
    Vendor Product Version
    deltaww dialink *
    deltaww dialink 1.5.0.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "DIALink",
              "vendor": "Delta Industrial Automation",
              "versions": [
                {
                  "lessThan": "1.5.0.0 Beta 4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0763E298-F79A-4604-B963-139473FC1368",
                  "versionEndExcluding": "1.5.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:1.5.0.0:beta3:*:*:*:*:*:*",
                  "matchCriteriaId": "8FC7C242-820D-4CF0-B408-78BC13C76BBE",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory."
        },
        {
          "lang": "es",
          "value": "Las versiones DIALink de Delta Industrial Automation anteriores a v1.5.0.0 Beta 4 utilizan una entrada externa para construir un nombre de ruta destinado a identificar un archivo o directorio ubicado debajo de un directorio principal restringido. Sin embargo, el software no neutraliza adecuadamente los elementos especiales dentro del nombre de la ruta, lo que puede hacer que el nombre de la ruta se resuelva en una ubicaci\u00f3n fuera del directorio restringido."
        }
      ],
      "id": "CVE-2022-2969",
      "lastModified": "2026-06-17T04:42:54.220",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.2,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-2969",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-04-16T15:49:14.906906Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-12-01T18:15:10.207",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-307-03"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-307-03"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2022-2660

    Vulnerability from fkie_nvd - Published: 2022-12-13 22:15 - Updated: 2026-06-17 04:42
    Summary
    Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Industrial Automation DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": " 1.4.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFE1DAD0-0AC9-4431-B554-16D8A2A7A36B",
                  "versionEndIncluding": "1.4.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Industrial Automation DIALink versions 1.4.0.0 and prior are\u00a0vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.\n\n\n\n\n\n"
        },
        {
          "lang": "es",
          "value": "Las versiones 1.4.0.0 y anteriores de Delta Industrial Automation DIALink son vulnerables al uso de una clave criptogr\u00e1fica codificada que podr\u00eda permitir a un atacante descifrar datos confidenciales y comprometer la m\u00e1quina."
        }
      ],
      "id": "CVE-2022-2660",
      "lastModified": "2026-06-17T04:42:18.080",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-2660",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-04-16T15:52:26.337503Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-12-13T22:15:09.910",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-321"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-798"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-38488

    Vulnerability from fkie_nvd - Published: 2021-11-03 20:15 - Updated: 2026-06-17 04:02
    Summary
    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter comment of the API events, which may allow an attacker to remotely execute code.
    References
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.4.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A2B37F1B-6DB2-4F02-A633-27D40E524D24",
                  "versionEndIncluding": "1.2.4.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter comment of the API events, which may allow an attacker to remotely execute code."
        },
        {
          "lang": "es",
          "value": "Delta Electronics DIALink versiones 1.2.4.0 y anteriores, es vulnerable a un ataque de tipo cross-site scripting porque un atacante autenticado puede inyectar c\u00f3digo JavaScript arbitrario en el comentario del par\u00e1metro de los eventos API, que puede permitir a un atacante ejecutar c\u00f3digo de forma remota"
        }
      ],
      "id": "CVE-2021-38488",
      "lastModified": "2026-06-17T04:02:12.770",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "LOW",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 3.5,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 6.8,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.3,
            "impactScore": 2.7,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.7,
            "impactScore": 2.7,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-11-03T20:15:08.937",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-79"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-38428

    Vulnerability from fkie_nvd - Published: 2021-11-03 20:15 - Updated: 2026-06-17 04:02
    Summary
    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code.
    References
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.4.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A2B37F1B-6DB2-4F02-A633-27D40E524D24",
                  "versionEndIncluding": "1.2.4.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code."
        },
        {
          "lang": "es",
          "value": "Delta Electronics DIALink versiones 1.2.4.0 y anteriores, son vulnerables a un ataque de tipo cross-site scripting porque un atacante autenticado puede inyectar c\u00f3digo JavaScript arbitrario en el nombre del par\u00e1metro de la programaci\u00f3n de la API, que puede permitir a un atacante ejecutar c\u00f3digo de forma remota"
        }
      ],
      "id": "CVE-2021-38428",
      "lastModified": "2026-06-17T04:02:04.827",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "LOW",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 3.5,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 6.8,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.3,
            "impactScore": 2.7,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.7,
            "impactScore": 2.7,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-11-03T20:15:08.883",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-79"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-38424

    Vulnerability from fkie_nvd - Published: 2021-11-03 20:15 - Updated: 2026-06-17 04:02
    Summary
    The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application.
    References
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.4.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A2B37F1B-6DB2-4F02-A633-27D40E524D24",
                  "versionEndIncluding": "1.2.4.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application."
        },
        {
          "lang": "es",
          "value": "La interfaz de etiquetas de Delta Electronics DIALink versiones 1.2.4.0 y anteriores, es vulnerable a que un atacante inyecte f\u00f3rmulas en los datos de las etiquetas. Esas f\u00f3rmulas podr\u00edan ejecutarse cuando es abierto con una aplicaci\u00f3n de hoja de c\u00e1lculo"
        }
      ],
      "id": "CVE-2021-38424",
      "lastModified": "2026-06-17T04:02:04.343",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 1.7,
            "impactScore": 3.7,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-11-03T20:15:08.827",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-1236"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-38422

    Vulnerability from fkie_nvd - Published: 2021-11-03 20:15 - Updated: 2026-06-17 04:02
    Summary
    Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.
    References
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.4.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A2B37F1B-6DB2-4F02-A633-27D40E524D24",
                  "versionEndIncluding": "1.2.4.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges."
        },
        {
          "lang": "es",
          "value": "Delta Electronics DIALink versiones 1.2.4.0 y anteriores, almacena informaci\u00f3n confidencial en texto sin cifrar, que puede permitir a un atacante tener un amplio acceso al directorio de la aplicaci\u00f3n y escalar privilegios"
        }
      ],
      "id": "CVE-2021-38422",
      "lastModified": "2026-06-17T04:02:04.110",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.6,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-11-03T20:15:08.773",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-312"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-38420

    Vulnerability from fkie_nvd - Published: 2021-11-03 20:15 - Updated: 2026-06-17 04:02
    Summary
    Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files.
    References
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.4.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A2B37F1B-6DB2-4F02-A633-27D40E524D24",
                  "versionEndIncluding": "1.2.4.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files."
        },
        {
          "lang": "es",
          "value": "Delta Electronics DIALink versiones 1.2.4.0 y anteriores, los permisos predeterminados otorgan amplios permisos a cuentas de usuario con pocos privilegios, que puede permitir a un atacante modificar el directorio de instalaci\u00f3n y cargar archivos maliciosos"
        }
      ],
      "id": "CVE-2021-38420",
      "lastModified": "2026-06-17T04:02:03.887",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.6,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-11-03T20:15:08.720",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-427"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-276"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-38418

    Vulnerability from fkie_nvd - Published: 2021-11-03 20:15 - Updated: 2026-06-17 04:02
    Summary
    Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization.
    References
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.4.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A2B37F1B-6DB2-4F02-A633-27D40E524D24",
                  "versionEndIncluding": "1.2.4.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization."
        },
        {
          "lang": "es",
          "value": "Delta Electronics DIALink versiones 1.2.4.0 y anteriores, son ejecutadas por defecto en HTTP, lo que puede permitir a un atacante situarse entre el tr\u00e1fico y llevar a cabo un ataque de tipo machine-in-the-middle para acceder a la informaci\u00f3n sin autorizaci\u00f3n"
        }
      ],
      "id": "CVE-2021-38418",
      "lastModified": "2026-06-17T04:02:03.667",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-11-03T20:15:08.663",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-319"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-38416

    Vulnerability from fkie_nvd - Published: 2021-11-03 20:15 - Updated: 2026-06-17 04:02
    Summary
    Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed.
    References
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.4.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A2B37F1B-6DB2-4F02-A633-27D40E524D24",
                  "versionEndIncluding": "1.2.4.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed."
        },
        {
          "lang": "es",
          "value": "Delta Electronics DIALink versiones 1.2.4.0 y anteriores, cargan bibliotecas de forma no segura, lo que puede permitir a un atacante usar un secuestro de DLL y tomar el control del sistema donde est\u00e1 instalado el software"
        }
      ],
      "id": "CVE-2021-38416",
      "lastModified": "2026-06-17T04:02:03.437",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.4,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 3.4,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-11-03T20:15:08.597",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-427"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-38411

    Vulnerability from fkie_nvd - Published: 2021-11-03 20:15 - Updated: 2026-06-17 04:02
    Summary
    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacker to remotely execute code.
    References
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.4.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A2B37F1B-6DB2-4F02-A633-27D40E524D24",
                  "versionEndIncluding": "1.2.4.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacker to remotely execute code."
        },
        {
          "lang": "es",
          "value": "Delta Electronics DIALink versiones 1.2.4.0 y anteriores, es vulnerable a un ataque de tipo cross-site scripting porque un atacante autenticado puede inyectar c\u00f3digo JavaScript arbitrario en el par\u00e1metro deviceName de la API modbusWriter-Reader, lo que puede permitir a un atacante ejecutar c\u00f3digo de forma remota"
        }
      ],
      "id": "CVE-2021-38411",
      "lastModified": "2026-06-17T04:02:02.980",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "LOW",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 3.5,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 6.8,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.3,
            "impactScore": 2.7,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.7,
            "impactScore": 2.7,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-11-03T20:15:08.540",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-79"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-38407

    Vulnerability from fkie_nvd - Published: 2021-11-03 20:15 - Updated: 2026-06-17 04:02
    Summary
    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely execute code.
    References
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.4.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A2B37F1B-6DB2-4F02-A633-27D40E524D24",
                  "versionEndIncluding": "1.2.4.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely execute code."
        },
        {
          "lang": "es",
          "value": "Delta Electronics DIALink versiones 1.2.4.0 y anteriores, son vulnerables a un ataque de tipo cross-site scripting porque un atacante autenticado puede inyectar c\u00f3digo JavaScript arbitrario en el par\u00e1metro deviceName de la API devices, que puede permitir a un atacante ejecutar c\u00f3digo de forma remota"
        }
      ],
      "id": "CVE-2021-38407",
      "lastModified": "2026-06-17T04:02:02.503",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "LOW",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 3.5,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 6.8,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.3,
            "impactScore": 2.7,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.7,
            "impactScore": 2.7,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-11-03T20:15:08.480",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-79"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-38403

    Vulnerability from fkie_nvd - Published: 2021-11-03 20:15 - Updated: 2026-06-17 04:02
    Summary
    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remotely execute code.
    References
    Impacted products
    Vendor Product Version
    deltaww dialink *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.4.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:deltaww:dialink:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A2B37F1B-6DB2-4F02-A633-27D40E524D24",
                  "versionEndIncluding": "1.2.4.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remotely execute code."
        },
        {
          "lang": "es",
          "value": "Delta Electronics DIALink versiones 1.2.4.0 y anteriores, es vulnerable a un ataque de tipo cross-site scripting porque un atacante autenticado puede inyectar c\u00f3digo JavaScript arbitrario en el par\u00e1metro proveedor del mantenimiento de la API, que puede permitir a un atacante ejecutar c\u00f3digo de forma remota"
        }
      ],
      "id": "CVE-2021-38403",
      "lastModified": "2026-06-17T04:02:01.983",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "LOW",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 3.5,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 6.8,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.3,
            "impactScore": 2.7,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.7,
            "impactScore": 2.7,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-11-03T20:15:08.397",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-79"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    VAR-202509-3613

    Vulnerability from variot - Updated: 2025-10-10 23:28

    Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. Delta Electronics, INC. of DIALink Exists in a past traversal vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to overwrite configuration files on affected installations of Delta Electronics DIALink. Authentication is not required to exploit this vulnerability.The specific flaw exists within the web service, which listens on TCP port 7631 by default. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202509-3613",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": null,
            "trust": 1.5,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "dialink",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.8.0.0"
          },
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "delta",
            "version": "1.8.0.0"
          },
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "electronics dialink",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "delta",
            "version": "\u003c=1.6.0.0"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-927"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22947"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015154"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58320"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Anonymous",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-927"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2025-58320",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-22947",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "759f5e80-c8e1-4224-bead-956d7b33c98b",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-58320",
                "impactScore": 3.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "Low",
                "baseScore": 7.3,
                "baseSeverity": "High",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2025-58320",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ZDI",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-58320",
                "impactScore": 3.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "NONE",
                "vectorString": "AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "759f5e80-c8e1-4224-bead-956d7b33c98b",
                "id": "CVE-2025-58320",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-58320",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2025-58320",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2025-58320",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-22947",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-927"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22947"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015154"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58320"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58320"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. Delta Electronics, INC. of DIALink Exists in a past traversal vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to overwrite configuration files on affected installations of Delta Electronics DIALink. Authentication is not required to exploit this vulnerability.The specific flaw exists within the web service, which listens on TCP port 7631 by default. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-58320"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015154"
          },
          {
            "db": "ZDI",
            "id": "ZDI-25-927"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22947"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-58320",
            "trust": 3.9
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-25-259-07",
            "trust": 0.8
          },
          {
            "db": "JVN",
            "id": "JVNVU98116919",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015154",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-26843",
            "trust": 0.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-25-927",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22947",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-927"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22947"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015154"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58320"
          }
        ]
      },
      "id": "VAR-202509-3613",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-22947"
          }
        ],
        "trust": 1.2926407
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-22947"
          }
        ]
      },
      "last_update_date": "2025-10-10T23:28:40.302000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Delta Electronics has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-259-07"
          },
          {
            "title": "Patch for Delta Electronics DIALink Directory Traversal Vulnerability (CNVD-2025-22947)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/738706"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-927"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22947"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-22",
            "trust": 1.0
          },
          {
            "problemtype": "Path traversal (CWE-22) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015154"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58320"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://filecenter.deltaww.com/news/download/doc/delta-pcsa-2025-00016_dialink%20-%20directory%20traversal%20authentication%20bypass%20vulnerability.pdf"
          },
          {
            "trust": 1.5,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-259-07"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu98116919/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-58320"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-927"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22947"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015154"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58320"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-25-927"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22947"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015154"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58320"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-01T00:00:00",
            "db": "ZDI",
            "id": "ZDI-25-927"
          },
          {
            "date": "2025-09-29T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-22947"
          },
          {
            "date": "2025-10-06T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-015154"
          },
          {
            "date": "2025-09-11T09:15:34.807000",
            "db": "NVD",
            "id": "CVE-2025-58320"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-01T00:00:00",
            "db": "ZDI",
            "id": "ZDI-25-927"
          },
          {
            "date": "2025-09-29T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-22947"
          },
          {
            "date": "2025-10-06T08:44:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-015154"
          },
          {
            "date": "2025-09-26T14:43:41.973000",
            "db": "NVD",
            "id": "CVE-2025-58320"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta\u00a0Electronics,\u00a0INC.\u00a0 of \u00a0DIALink\u00a0 Past traversal vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015154"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202509-3042

    Vulnerability from variot - Updated: 2025-10-03 23:32

    Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics DIALink. Authentication is not required to exploit this vulnerability.The specific flaw exists within the DataCenter service, which listens on TCP port 7631 by default. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Delta Electronics DIALink is an industrial automation communication gateway from Delta Electronics, a Chinese company

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202509-3042",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.8.0.0"
          },
          {
            "model": "dialink",
            "scope": null,
            "trust": 0.7,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "electronics dialink",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "delta",
            "version": "\u003c=1.6.0.0"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-926"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22948"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58321"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Anonymous",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-926"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2025-58321",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-22948",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "759f5e80-c8e1-4224-bead-956d7b33c98b",
                "availabilityImpact": "HIGH",
                "baseScore": 10.0,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-58321",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 10.0,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-58321",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 0.7,
                "userInteraction": "NONE",
                "vectorString": "AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "759f5e80-c8e1-4224-bead-956d7b33c98b",
                "id": "CVE-2025-58321",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "ZDI",
                "id": "CVE-2025-58321",
                "trust": 0.7,
                "value": "CRITICAL"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-22948",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-926"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22948"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58321"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics DIALink. Authentication is not required to exploit this vulnerability.The specific flaw exists within the DataCenter service, which listens on TCP port 7631 by default. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Delta Electronics DIALink is an industrial automation communication gateway from Delta Electronics, a Chinese company",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-58321"
          },
          {
            "db": "ZDI",
            "id": "ZDI-25-926"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22948"
          }
        ],
        "trust": 2.07
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-58321",
            "trust": 2.3
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-26827",
            "trust": 0.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-25-926",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22948",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-926"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22948"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58321"
          }
        ]
      },
      "id": "VAR-202509-3042",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-22948"
          }
        ],
        "trust": 1.2926407
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-22948"
          }
        ]
      },
      "last_update_date": "2025-10-03T23:32:49.250000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Delta Electronics has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-259-07"
          },
          {
            "title": "Patch for Delta Electronics DIALink Directory Traversal Vulnerability (CNVD-2025-22948)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/738711"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-926"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22948"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-22",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-58321"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.6,
            "url": "https://filecenter.deltaww.com/news/download/doc/delta-pcsa-2025-00016_dialink%20-%20directory%20traversal%20authentication%20bypass%20vulnerability.pdf"
          },
          {
            "trust": 0.7,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-259-07"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-926"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22948"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58321"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-25-926"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-22948"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-58321"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-01T00:00:00",
            "db": "ZDI",
            "id": "ZDI-25-926"
          },
          {
            "date": "2025-09-29T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-22948"
          },
          {
            "date": "2025-09-11T09:15:35.010000",
            "db": "NVD",
            "id": "CVE-2025-58321"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-01T00:00:00",
            "db": "ZDI",
            "id": "ZDI-25-926"
          },
          {
            "date": "2025-09-29T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-22948"
          },
          {
            "date": "2025-09-26T14:43:15.530000",
            "db": "NVD",
            "id": "CVE-2025-58321"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Electronics DIALink Directory Traversal Remote Code Execution Vulnerability",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-926"
          }
        ],
        "trust": 0.7
      }
    }

    VAR-202211-0095

    Vulnerability from variot - Updated: 2024-08-14 14:49

    Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory. This vulnerability allows remote attackers to create arbitrary files on affected installations of Delta Industrial Automation DIALink. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.The specific flaw exists within the opcua endpoint of the web service, which listens on TCP port 5000 by default. When parsing the filename parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create files in the context of the web service. Delta Electronics Industrial Automation DIALink is an industrial automation IoT device from Delta Electronics, Taiwan, China

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202211-0095",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.5.0.0"
          },
          {
            "model": "dialink",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.5.0.0"
          },
          {
            "model": "dialink",
            "scope": null,
            "trust": 0.7,
            "vendor": "delta",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-23-671"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2969"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Y4er",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-23-671"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2022-2969",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-2969",
                "impactScore": 3.6,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ics-cert@hq.dhs.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2022-2969",
                "impactScore": 5.2,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2022-2969",
                "impactScore": 5.2,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "NONE",
                "vectorString": "AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-2969",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "ics-cert@hq.dhs.gov",
                "id": "CVE-2022-2969",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "ZDI",
                "id": "CVE-2022-2969",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202211-2069",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-23-671"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-2069"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2969"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2969"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory. This vulnerability allows remote attackers to create arbitrary files on affected installations of Delta Industrial Automation DIALink. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.The specific flaw exists within the opcua endpoint of the web service, which listens on TCP port 5000 by default. When parsing the filename parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create files in the context of the web service. Delta Electronics Industrial Automation DIALink is an industrial automation IoT device from Delta Electronics, Taiwan, China",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-2969"
          },
          {
            "db": "ZDI",
            "id": "ZDI-23-671"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-2069"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-2969"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-2969",
            "trust": 2.4
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-22-307-03",
            "trust": 1.7
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-16888",
            "trust": 0.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-23-671",
            "trust": 0.7
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2022.5578",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-2069",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-2969",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-23-671"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-2969"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-2069"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2969"
          }
        ]
      },
      "id": "VAR-202211-0095",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.6926407
      },
      "last_update_date": "2024-08-14T14:49:31.296000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Delta Electronics has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-307-03"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-23-671"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-22",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-2969"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-307-03"
          },
          {
            "trust": 0.7,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-307-03"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-2969/"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2022.5578"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/22.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-23-671"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-2969"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-2069"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2969"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-23-671"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-2969"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-2069"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2969"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-05-17T00:00:00",
            "db": "ZDI",
            "id": "ZDI-23-671"
          },
          {
            "date": "2022-12-01T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-2969"
          },
          {
            "date": "2022-11-04T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-2069"
          },
          {
            "date": "2022-12-01T18:15:10.207000",
            "db": "NVD",
            "id": "CVE-2022-2969"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-05-17T00:00:00",
            "db": "ZDI",
            "id": "ZDI-23-671"
          },
          {
            "date": "2022-12-01T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-2969"
          },
          {
            "date": "2022-12-08T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202211-2069"
          },
          {
            "date": "2022-12-07T14:34:35.657000",
            "db": "NVD",
            "id": "CVE-2022-2969"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-2069"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Industrial Automation DIALink Directory Traversal Arbitrary File Creation Vulnerability",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-23-671"
          }
        ],
        "trust": 0.7
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "path traversal",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202211-2069"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202208-1663

    Vulnerability from variot - Updated: 2024-08-14 14:37

    Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine. Delta Electronics Provided by the company DIALink contains the following vulnerabilities: * Using hardcoded encryption keys (CWE-321) - CVE-2022-2660If the vulnerability is exploited, it may be affected as follows. It was * Sensitive encrypted data stored on the device may be decrypted by a remote third party. This vulnerability allows remote attackers to bypass authentication on affected installations of Delta Industrial Automation DIALink. Authentication is not required to exploit this vulnerability.The specific flaw exists within the authorization of requests to the server. The issue results from hardcoding crytographic keys within the product. An attacker can leverage this vulnerability to bypass authentication on the system. Delta Electronics Industrial Automation DIALink is an industrial automation IoT device from Delta Electronics, Taiwan, China

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202208-1663",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.4.0.0"
          },
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "delta",
            "version": "v1.4.0.0  and earlier"
          },
          {
            "model": "dialink",
            "scope": null,
            "trust": 0.7,
            "vendor": "delta",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-22-1166"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-002361"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2660"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Y4er",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-22-1166"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2022-2660",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-2660",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ics-cert@hq.dhs.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-2660",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2022-2660",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2022-2660",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "NONE",
                "vectorString": "AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2022-2660",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "ics-cert@hq.dhs.gov",
                "id": "CVE-2022-2660",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2022-2660",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2022-2660",
                "trust": 0.7,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202208-3794",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-22-1166"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-002361"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202208-3794"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2660"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2660"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Industrial Automation DIALink versions 1.4.0.0 and prior are\u00a0vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine. Delta Electronics Provided by the company DIALink contains the following vulnerabilities: * Using hardcoded encryption keys (CWE-321) - CVE-2022-2660If the vulnerability is exploited, it may be affected as follows. It was * Sensitive encrypted data stored on the device may be decrypted by a remote third party. This vulnerability allows remote attackers to bypass authentication on affected installations of Delta Industrial Automation DIALink. Authentication is not required to exploit this vulnerability.The specific flaw exists within the authorization of requests to the server. The issue results from hardcoding crytographic keys within the product. An attacker can leverage this vulnerability to bypass authentication on the system. Delta Electronics Industrial Automation DIALink is an industrial automation IoT device from Delta Electronics, Taiwan, China",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-2660"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-002361"
          },
          {
            "db": "ZDI",
            "id": "ZDI-22-1166"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202208-3794"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-2660",
            "trust": 4.0
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-22-235-02",
            "trust": 2.5
          },
          {
            "db": "JVN",
            "id": "JVNVU99763068",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-002361",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-16889",
            "trust": 0.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-22-1166",
            "trust": 0.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202208-3794",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-2660",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-22-1166"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-2660"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-002361"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202208-3794"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2660"
          }
        ]
      },
      "id": "VAR-202208-1663",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.6926407
      },
      "last_update_date": "2024-08-14T14:37:20.383000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Contact\u00a0Us",
            "trust": 0.8,
            "url": "https://www.deltaww.com/en/customerService"
          },
          {
            "title": "Delta Electronics has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02"
          },
          {
            "title": "Delta Electronics Industrial Automation DIALink Repair measures for trust management problem vulnerabilities",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=217984"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-22-1166"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-002361"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202208-3794"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-321",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-798",
            "trust": 1.0
          },
          {
            "problemtype": "Using hardcoded encryption keys (CWE-321) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-002361"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2660"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.2,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02"
          },
          {
            "trust": 0.8,
            "url": "http://jvn.jp/vu/jvnvu99763068/index.html"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2022-2660"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-2660/"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-235-02"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-22-1166"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-2660"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-002361"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202208-3794"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2660"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-22-1166"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-2660"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-002361"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202208-3794"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-2660"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-08-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-22-1166"
          },
          {
            "date": "2022-09-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-002361"
          },
          {
            "date": "2022-08-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202208-3794"
          },
          {
            "date": "2022-12-13T22:15:09.910000",
            "db": "NVD",
            "id": "CVE-2022-2660"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-08-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-22-1166"
          },
          {
            "date": "2024-05-31T09:14:00",
            "db": "JVNDB",
            "id": "JVNDB-2022-002361"
          },
          {
            "date": "2022-12-19T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202208-3794"
          },
          {
            "date": "2023-11-07T03:46:50.010000",
            "db": "NVD",
            "id": "CVE-2022-2660"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202208-3794"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta\u00a0Electronics\u00a0 Made \u00a0DIALink\u00a0 Vulnerability of using hard-coded encryption keys in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2022-002361"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202208-3794"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202111-0278

    Vulnerability from variot - Updated: 2024-08-14 13:53

    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remotely execute code. Delta Electronics DIALink Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state.

    DIALink 1.2.4.0 and earlier versions have a cross-site scripting vulnerability

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202111-0278",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.2.4.0"
          },
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "delta",
            "version": "1.2.4.0  and earlier"
          },
          {
            "model": "electronics dialink",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "delta",
            "version": "\u003c=1.2.4.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84839"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014634"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38403"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Michael Heinzl reported these vulnerabilities to CISA.",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1541"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2021-38403",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CVE-2021-38403",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CNVD-2021-84839",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-38403",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ics-cert@hq.dhs.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.3,
                "id": "CVE-2021-38403",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2021-38403",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "High",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-38403",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "ics-cert@hq.dhs.gov",
                "id": "CVE-2021-38403",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-38403",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-84839",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202110-1541",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84839"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014634"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1541"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38403"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38403"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remotely execute code. Delta Electronics DIALink Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state. \n\r\n\r\nDIALink 1.2.4.0 and earlier versions have a cross-site scripting vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-38403"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014634"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84839"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-38403",
            "trust": 3.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-294-02",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU94767496",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014634",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84839",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.3528",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2021102209",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1541",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84839"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014634"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1541"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38403"
          }
        ]
      },
      "id": "VAR-202111-0278",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84839"
          }
        ],
        "trust": 1.2926407
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84839"
          }
        ]
      },
      "last_update_date": "2024-08-14T13:53:51.211000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://www.deltaww.com/en-US/index"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014634"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.0
          },
          {
            "problemtype": "Cross-site scripting (CWE-79) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014634"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38403"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.8,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38403"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu94767496/"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2021102209"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.3528"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84839"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014634"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1541"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38403"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84839"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014634"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1541"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38403"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-11-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84839"
          },
          {
            "date": "2022-10-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014634"
          },
          {
            "date": "2021-10-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1541"
          },
          {
            "date": "2021-11-03T20:15:08.397000",
            "db": "NVD",
            "id": "CVE-2021-38403"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84839"
          },
          {
            "date": "2022-10-21T07:58:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014634"
          },
          {
            "date": "2021-11-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1541"
          },
          {
            "date": "2021-11-05T13:43:49.683000",
            "db": "NVD",
            "id": "CVE-2021-38403"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1541"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta\u00a0Electronics\u00a0DIALink\u00a0 Cross-site scripting vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014634"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1541"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202111-0250

    Vulnerability from variot - Updated: 2024-08-14 13:53

    Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization. Delta Electronics DIALink Contains a vulnerability in the transmission of important information in clear text.Information may be obtained. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state. An attacker could exploit this vulnerability to gain unauthorized access to information through a machine-in-the-middle attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202111-0250",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.2.4.0"
          },
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "delta",
            "version": "1.2.4.0  and earlier"
          },
          {
            "model": "electronics dialink",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "delta",
            "version": "\u003c=1.2.4.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84842"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014638"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38418"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Michael Heinzl reported these vulnerabilities to CISA.",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1557"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2021-38418",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2021-38418",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CNVD-2021-84842",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.2,
                "id": "CVE-2021-38418",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "ics-cert@hq.dhs.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-38418",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.9,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-38418",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-38418",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "ics-cert@hq.dhs.gov",
                "id": "CVE-2021-38418",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-38418",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-84842",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202110-1557",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84842"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014638"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1557"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38418"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38418"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization. Delta Electronics DIALink Contains a vulnerability in the transmission of important information in clear text.Information may be obtained. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state. An attacker could exploit this vulnerability to gain unauthorized access to information through a machine-in-the-middle attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-38418"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014638"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84842"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-38418",
            "trust": 3.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-294-02",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU94767496",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014638",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84842",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.3528",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2021102209",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1557",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84842"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014638"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1557"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38418"
          }
        ]
      },
      "id": "VAR-202111-0250",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84842"
          }
        ],
        "trust": 1.2926407
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84842"
          }
        ]
      },
      "last_update_date": "2024-08-14T13:53:47.846000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://www.deltaww.com/en-US/index"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014638"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-319",
            "trust": 1.0
          },
          {
            "problemtype": "Sending important information in clear text (CWE-319) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014638"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38418"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.2,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38418"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu94767496/"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2021102209"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.3528"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84842"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014638"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1557"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38418"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84842"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014638"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1557"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38418"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-11-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84842"
          },
          {
            "date": "2022-10-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014638"
          },
          {
            "date": "2021-10-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1557"
          },
          {
            "date": "2021-11-03T20:15:08.663000",
            "db": "NVD",
            "id": "CVE-2021-38418"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84842"
          },
          {
            "date": "2022-10-21T07:58:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014638"
          },
          {
            "date": "2021-11-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1557"
          },
          {
            "date": "2021-11-05T14:58:13.887000",
            "db": "NVD",
            "id": "CVE-2021-38418"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1557"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta\u00a0Electronics\u00a0DIALink\u00a0 Vulnerability in plaintext transmission of important information in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014638"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1557"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202111-0247

    Vulnerability from variot - Updated: 2024-08-14 13:53

    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code. Delta Electronics DIALink Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state.

    DIALink 1.2.4.0 and earlier versions have a cross-site scripting vulnerability

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202111-0247",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.2.4.0"
          },
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "delta",
            "version": "1.2.4.0  and earlier"
          },
          {
            "model": "electronics dialink",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "delta",
            "version": "\u003c=1.2.4.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84841"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014625"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38428"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Michael Heinzl reported these vulnerabilities to CISA.",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1553"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2021-38428",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CVE-2021-38428",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 1.9,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CNVD-2021-84841",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-38428",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ics-cert@hq.dhs.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.3,
                "id": "CVE-2021-38428",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2021-38428",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "High",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-38428",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "ics-cert@hq.dhs.gov",
                "id": "CVE-2021-38428",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-38428",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-84841",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202110-1553",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-38428",
                "trust": 0.1,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84841"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-38428"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014625"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1553"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38428"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38428"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code. Delta Electronics DIALink Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state. \n\r\n\r\nDIALink 1.2.4.0 and earlier versions have a cross-site scripting vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-38428"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014625"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84841"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-38428"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-38428",
            "trust": 3.9
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-294-02",
            "trust": 3.1
          },
          {
            "db": "JVN",
            "id": "JVNVU94767496",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014625",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84841",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.3528",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2021102209",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1553",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-38428",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84841"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-38428"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014625"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1553"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38428"
          }
        ]
      },
      "id": "VAR-202111-0247",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84841"
          }
        ],
        "trust": 1.2926407
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84841"
          }
        ]
      },
      "last_update_date": "2024-08-14T13:53:47.816000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://www.deltaww.com/en-US/index"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014625"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.0
          },
          {
            "problemtype": "Cross-site scripting (CWE-79) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014625"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38428"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.9,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38428"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu94767496/"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2021102209"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.3528"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/79.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84841"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-38428"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014625"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1553"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38428"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84841"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-38428"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014625"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1553"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38428"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-11-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84841"
          },
          {
            "date": "2021-11-03T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-38428"
          },
          {
            "date": "2022-10-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014625"
          },
          {
            "date": "2021-10-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1553"
          },
          {
            "date": "2021-11-03T20:15:08.883000",
            "db": "NVD",
            "id": "CVE-2021-38428"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84841"
          },
          {
            "date": "2021-11-05T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-38428"
          },
          {
            "date": "2022-10-21T06:28:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014625"
          },
          {
            "date": "2021-11-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1553"
          },
          {
            "date": "2021-11-05T14:05:35.653000",
            "db": "NVD",
            "id": "CVE-2021-38428"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1553"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta\u00a0Electronics\u00a0DIALink\u00a0 Cross-site scripting vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014625"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1553"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202111-0346

    Vulnerability from variot - Updated: 2024-08-14 13:53

    The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application. Delta Electronics DIALink for, CSV A vulnerability exists regarding the neutralization of formula elements in files.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work.

    DIALink 1.2.4.0 and earlier have security vulnerabilities. An attacker can exploit this vulnerability to inject formulas into label data and execute them

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202111-0346",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.2.4.0"
          },
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "delta",
            "version": "1.2.4.0  and earlier"
          },
          {
            "model": "electronics dialink",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "delta",
            "version": "\u003c=1.2.4.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84835"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014641"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38424"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Michael Heinzl reported these vulnerabilities to CISA.",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1530"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2021-38424",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2021-38424",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CNVD-2021-84835",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-38424",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ics-cert@hq.dhs.gov",
                "availabilityImpact": "LOW",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-38424",
                "impactScore": 3.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-38424",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-38424",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "ics-cert@hq.dhs.gov",
                "id": "CVE-2021-38424",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-38424",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-84835",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202110-1530",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84835"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014641"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1530"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38424"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38424"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application. Delta Electronics DIALink for, CSV A vulnerability exists regarding the neutralization of formula elements in files.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. \n\r\n\r\nDIALink 1.2.4.0 and earlier have security vulnerabilities. An attacker can exploit this vulnerability to inject formulas into label data and execute them",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-38424"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014641"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84835"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-38424",
            "trust": 3.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-294-02",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU94767496",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014641",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84835",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.3528",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2021102209",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1530",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84835"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014641"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1530"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38424"
          }
        ]
      },
      "id": "VAR-202111-0346",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84835"
          }
        ],
        "trust": 1.2926407
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84835"
          }
        ]
      },
      "last_update_date": "2024-08-14T13:53:47.785000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://www.deltaww.com/en-US/index"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014641"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-1236",
            "trust": 1.0
          },
          {
            "problemtype": "CSV Improper neutralization of math elements in the file (CWE-1236) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014641"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38424"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.2,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38424"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu94767496/"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2021102209"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.3528"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84835"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014641"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1530"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38424"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84835"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014641"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1530"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38424"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-11-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84835"
          },
          {
            "date": "2022-10-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014641"
          },
          {
            "date": "2021-10-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1530"
          },
          {
            "date": "2021-11-03T20:15:08.827000",
            "db": "NVD",
            "id": "CVE-2021-38424"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84835"
          },
          {
            "date": "2022-10-21T07:58:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014641"
          },
          {
            "date": "2021-11-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1530"
          },
          {
            "date": "2021-11-05T16:21:45.980000",
            "db": "NVD",
            "id": "CVE-2021-38424"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1530"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta\u00a0Electronics\u00a0DIALink\u00a0 In \u00a0CSV\u00a0 Vulnerability in neutralizing math elements in files",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014641"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1530"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202111-0246

    Vulnerability from variot - Updated: 2024-08-14 13:53

    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter comment of the API events, which may allow an attacker to remotely execute code. Delta Electronics DIALink Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state.

    DIALink 1.2.4.0 and earlier versions have a cross-site scripting vulnerability

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202111-0246",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.2.4.0"
          },
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "delta",
            "version": "1.2.4.0  and earlier"
          },
          {
            "model": "electronics dialink",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "delta",
            "version": "\u003c=1.2.4.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84840"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014626"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38488"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Michael Heinzl reported these vulnerabilities to CISA.",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1550"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2021-38488",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CVE-2021-38488",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CNVD-2021-84840",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-38488",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ics-cert@hq.dhs.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.3,
                "id": "CVE-2021-38488",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2021-38488",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "High",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-38488",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "ics-cert@hq.dhs.gov",
                "id": "CVE-2021-38488",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-38488",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-84840",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202110-1550",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84840"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014626"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1550"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38488"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38488"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter comment of the API events, which may allow an attacker to remotely execute code. Delta Electronics DIALink Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state. \n\r\n\r\nDIALink 1.2.4.0 and earlier versions have a cross-site scripting vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-38488"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014626"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84840"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-38488",
            "trust": 3.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-294-02",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU94767496",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014626",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84840",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.3528",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2021102209",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1550",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84840"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014626"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1550"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38488"
          }
        ]
      },
      "id": "VAR-202111-0246",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84840"
          }
        ],
        "trust": 1.2926407
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84840"
          }
        ]
      },
      "last_update_date": "2024-08-14T13:53:47.756000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://www.deltaww.com/en-US/index"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014626"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.0
          },
          {
            "problemtype": "Cross-site scripting (CWE-79) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014626"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38488"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.8,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38488"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu94767496/"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2021102209"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.3528"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84840"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014626"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1550"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38488"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84840"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014626"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1550"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38488"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-11-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84840"
          },
          {
            "date": "2022-10-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014626"
          },
          {
            "date": "2021-10-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1550"
          },
          {
            "date": "2021-11-03T20:15:08.937000",
            "db": "NVD",
            "id": "CVE-2021-38488"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84840"
          },
          {
            "date": "2022-10-21T06:28:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014626"
          },
          {
            "date": "2021-11-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1550"
          },
          {
            "date": "2021-11-05T14:06:05.740000",
            "db": "NVD",
            "id": "CVE-2021-38488"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1550"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta\u00a0Electronics\u00a0DIALink\u00a0 Cross-site scripting vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014626"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1550"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202111-0276

    Vulnerability from variot - Updated: 2024-08-14 13:53

    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacker to remotely execute code. Delta Electronics DIALink Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state.

    DIALink 1.2.4.0 and earlier versions have a cross-site scripting vulnerability

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202111-0276",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.2.4.0"
          },
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "delta",
            "version": "1.2.4.0  and earlier"
          },
          {
            "model": "electronics dialink",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "delta",
            "version": "\u003c=1.2.4.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84837"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014636"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38411"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Michael Heinzl reported these vulnerabilities to CISA.",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1536"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2021-38411",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CVE-2021-38411",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CNVD-2021-84837",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-38411",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ics-cert@hq.dhs.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.3,
                "id": "CVE-2021-38411",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2021-38411",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "High",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-38411",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "ics-cert@hq.dhs.gov",
                "id": "CVE-2021-38411",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-38411",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-84837",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202110-1536",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84837"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014636"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1536"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38411"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38411"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacker to remotely execute code. Delta Electronics DIALink Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state. \n\r\n\r\nDIALink 1.2.4.0 and earlier versions have a cross-site scripting vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-38411"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014636"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84837"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-38411",
            "trust": 3.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-294-02",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU94767496",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014636",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84837",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.3528",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2021102209",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1536",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84837"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014636"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1536"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38411"
          }
        ]
      },
      "id": "VAR-202111-0276",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84837"
          }
        ],
        "trust": 1.2926407
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84837"
          }
        ]
      },
      "last_update_date": "2024-08-14T13:53:47.729000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://www.deltaww.com/en-US/index"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014636"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.0
          },
          {
            "problemtype": "Cross-site scripting (CWE-79) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014636"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38411"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.8,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38411"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu94767496/"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2021102209"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.3528"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84837"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014636"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1536"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38411"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84837"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014636"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1536"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38411"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-11-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84837"
          },
          {
            "date": "2022-10-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014636"
          },
          {
            "date": "2021-10-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1536"
          },
          {
            "date": "2021-11-03T20:15:08.540000",
            "db": "NVD",
            "id": "CVE-2021-38411"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84837"
          },
          {
            "date": "2022-10-21T07:58:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014636"
          },
          {
            "date": "2021-11-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1536"
          },
          {
            "date": "2021-11-05T13:40:54.753000",
            "db": "NVD",
            "id": "CVE-2021-38411"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1536"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta\u00a0Electronics\u00a0DIALink\u00a0 Cross-site scripting vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014636"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1536"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202111-0249

    Vulnerability from variot - Updated: 2024-08-14 13:53

    Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files. Delta Electronics DIALink There is a vulnerability in improper default permissions.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work.

    DIALink 1.2.4.0 and earlier versions have an incorrect default permission vulnerability

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202111-0249",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.2.4.0"
          },
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "delta",
            "version": "1.2.4.0  and earlier"
          },
          {
            "model": "electronics dialink",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "delta",
            "version": "\u003c=1.2.4.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84833"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014639"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38420"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Michael Heinzl reported these vulnerabilities to CISA.",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1527"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2021-38420",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.6,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.9,
                "id": "CVE-2021-38420",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.6,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2021-84833",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-38420",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2021-014639",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-38420",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "ics-cert@hq.dhs.gov",
                "id": "CVE-2021-38420",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-38420",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-84833",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202110-1527",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84833"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014639"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1527"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38420"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38420"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files. Delta Electronics DIALink There is a vulnerability in improper default permissions.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. \n\r\n\r\nDIALink 1.2.4.0 and earlier versions have an incorrect default permission vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-38420"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014639"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84833"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-38420",
            "trust": 3.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-294-02",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU94767496",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014639",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84833",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.3528",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2021102209",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1527",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84833"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014639"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1527"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38420"
          }
        ]
      },
      "id": "VAR-202111-0249",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84833"
          }
        ],
        "trust": 1.2926407
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84833"
          }
        ]
      },
      "last_update_date": "2024-08-14T13:53:47.700000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://www.deltaww.com/en-US/index"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014639"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-276",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-427",
            "trust": 1.0
          },
          {
            "problemtype": "Inappropriate default permissions (CWE-276) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014639"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38420"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.8,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38420"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu94767496/"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2021102209"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.3528"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84833"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014639"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1527"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38420"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84833"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014639"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1527"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38420"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-11-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84833"
          },
          {
            "date": "2022-10-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014639"
          },
          {
            "date": "2021-10-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1527"
          },
          {
            "date": "2021-11-03T20:15:08.720000",
            "db": "NVD",
            "id": "CVE-2021-38420"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84833"
          },
          {
            "date": "2022-10-21T07:58:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014639"
          },
          {
            "date": "2021-11-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1527"
          },
          {
            "date": "2021-11-05T15:06:21.217000",
            "db": "NVD",
            "id": "CVE-2021-38420"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1527"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta\u00a0Electronics\u00a0DIALink\u00a0 Vulnerability regarding improper default permissions in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014639"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "code problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1527"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202111-0277

    Vulnerability from variot - Updated: 2024-08-14 13:53

    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely execute code. Delta Electronics DIALink Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state.

    DIALink 1.2.4.0 and earlier versions have a cross-site scripting vulnerability

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202111-0277",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "deltaww",
            "version": "1.2.4.0"
          },
          {
            "model": "dialink",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "delta",
            "version": null
          },
          {
            "model": "dialink",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "delta",
            "version": "1.2.4.0  and earlier"
          },
          {
            "model": "electronics dialink",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "delta",
            "version": "\u003c=1.2.4.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84838"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014635"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38407"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Michael Heinzl reported these vulnerabilities to CISA.",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1546"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2021-38407",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CVE-2021-38407",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CNVD-2021-84838",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-38407",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "ics-cert@hq.dhs.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.3,
                "id": "CVE-2021-38407",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2021-38407",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "High",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-38407",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "ics-cert@hq.dhs.gov",
                "id": "CVE-2021-38407",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-38407",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-84838",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202110-1546",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84838"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014635"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1546"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38407"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38407"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely execute code. Delta Electronics DIALink Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. DIALink is a device networking platform launched by Delta Electronics, which can effectively manage CNC machine tools and PLC control machines, collect field device data and connect with the upper management platform through a unified interface, and provide visual information to reflect process parameters and equipment work. state. \n\r\n\r\nDIALink 1.2.4.0 and earlier versions have a cross-site scripting vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-38407"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014635"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84838"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-38407",
            "trust": 3.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-294-02",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU94767496",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014635",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-84838",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.3528",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2021102209",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1546",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84838"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014635"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1546"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38407"
          }
        ]
      },
      "id": "VAR-202111-0277",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84838"
          }
        ],
        "trust": 1.2926407
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84838"
          }
        ]
      },
      "last_update_date": "2024-08-14T13:53:47.672000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://www.deltaww.com/en-US/index"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014635"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.0
          },
          {
            "problemtype": "Cross-site scripting (CWE-79) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014635"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38407"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.8,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38407"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu94767496/"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-294-02"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2021102209"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.3528"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84838"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014635"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1546"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38407"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-84838"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014635"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1546"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-38407"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-11-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84838"
          },
          {
            "date": "2022-10-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014635"
          },
          {
            "date": "2021-10-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1546"
          },
          {
            "date": "2021-11-03T20:15:08.480000",
            "db": "NVD",
            "id": "CVE-2021-38407"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-84838"
          },
          {
            "date": "2022-10-21T07:58:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014635"
          },
          {
            "date": "2021-11-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202110-1546"
          },
          {
            "date": "2021-11-05T13:43:35.517000",
            "db": "NVD",
            "id": "CVE-2021-38407"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1546"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Delta\u00a0Electronics\u00a0DIALink\u00a0 Cross-site scripting vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014635"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202110-1546"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2025-58321 (GCVE-0-2025-58321)

    Vulnerability from nvd – Published: 2025-09-11 08:50 – Updated: 2025-09-11 14:36
    VLAI
    Title
    DIALink - Directory Traversal Authentication Bypass Vulnerability
    Summary
    Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-11 13:29 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Deltaww CNA under the icscert root
    CNA scorecard B 79/100 over 21 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Delta Electronics DIALink Affected: 0 , ≤ 1.6.0.0 (custom)
    Create a notification for this product.
    Date Public
    2025-09-11 07:22
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-58321",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T13:29:52.053857Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-11T14:36:18.886Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.6.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Independent researcher Rangin Sima (Kamel)"
            }
          ],
          "datePublic": "2025-09-11T07:22:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
                }
              ],
              "value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-11T08:50:41.974Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00016_DIALink%20-%20Directory%20Traversal%20Authentication%20Bypass%20Vulnerability.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
                }
              ],
              "value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "DIALink - Directory Traversal Authentication Bypass Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-58321",
        "datePublished": "2025-09-11T08:50:12.379Z",
        "dateReserved": "2025-08-28T06:15:58.627Z",
        "dateUpdated": "2025-09-11T14:36:18.886Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-58320 (GCVE-0-2025-58320)

    Vulnerability from nvd – Published: 2025-09-11 08:51 – Updated: 2025-09-11 14:36
    VLAI
    Title
    DIALink - Directory Traversal Authentication Bypass Vulnerability
    Summary
    Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-11 13:29 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Deltaww CNA under the icscert root
    CNA scorecard B 79/100 over 21 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Delta Electronics DIALink Affected: 0 , ≤ 1.6.0.0 (custom)
    Create a notification for this product.
    Date Public
    2025-09-11 07:22
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-58320",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T13:29:29.552980Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-11T14:36:13.786Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.6.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Independent researcher Rangin Sima (Kamel)"
            }
          ],
          "datePublic": "2025-09-11T07:22:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
                }
              ],
              "value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-11T08:51:49.981Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00016_DIALink%20-%20Directory%20Traversal%20Authentication%20Bypass%20Vulnerability.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
                }
              ],
              "value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "DIALink - Directory Traversal Authentication Bypass Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-58320",
        "datePublished": "2025-09-11T08:51:49.981Z",
        "dateReserved": "2025-08-28T06:15:58.627Z",
        "dateUpdated": "2025-09-11T14:36:13.786Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-58320 (GCVE-0-2025-58320)

    Vulnerability from cvelistv5 – Published: 2025-09-11 08:51 – Updated: 2025-09-11 14:36
    VLAI
    Title
    DIALink - Directory Traversal Authentication Bypass Vulnerability
    Summary
    Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-11 13:29 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Deltaww CNA under the icscert root
    CNA scorecard B 79/100 over 21 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Delta Electronics DIALink Affected: 0 , ≤ 1.6.0.0 (custom)
    Create a notification for this product.
    Date Public
    2025-09-11 07:22
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-58320",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T13:29:29.552980Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-11T14:36:13.786Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.6.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Independent researcher Rangin Sima (Kamel)"
            }
          ],
          "datePublic": "2025-09-11T07:22:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
                }
              ],
              "value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-11T08:51:49.981Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00016_DIALink%20-%20Directory%20Traversal%20Authentication%20Bypass%20Vulnerability.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
                }
              ],
              "value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "DIALink - Directory Traversal Authentication Bypass Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-58320",
        "datePublished": "2025-09-11T08:51:49.981Z",
        "dateReserved": "2025-08-28T06:15:58.627Z",
        "dateUpdated": "2025-09-11T14:36:13.786Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-58321 (GCVE-0-2025-58321)

    Vulnerability from cvelistv5 – Published: 2025-09-11 08:50 – Updated: 2025-09-11 14:36
    VLAI
    Title
    DIALink - Directory Traversal Authentication Bypass Vulnerability
    Summary
    Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-11 13:29 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Deltaww CNA under the icscert root
    CNA scorecard B 79/100 over 21 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Delta Electronics DIALink Affected: 0 , ≤ 1.6.0.0 (custom)
    Create a notification for this product.
    Date Public
    2025-09-11 07:22
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-58321",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-11T13:29:52.053857Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-11T14:36:18.886Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIALink",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.6.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Independent researcher Rangin Sima (Kamel)"
            }
          ],
          "datePublic": "2025-09-11T07:22:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
                }
              ],
              "value": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-11T08:50:41.974Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00016_DIALink%20-%20Directory%20Traversal%20Authentication%20Bypass%20Vulnerability.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
                }
              ],
              "value": "Users are recommended to download and upgrade to DIALink v1.8.0.0 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "DIALink - Directory Traversal Authentication Bypass Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-58321",
        "datePublished": "2025-09-11T08:50:12.379Z",
        "dateReserved": "2025-08-28T06:15:58.627Z",
        "dateUpdated": "2025-09-11T14:36:18.886Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }