Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for control_center_server by siemens

    CVE-2019-18342 (GCVE-0-2019-18342)

    Vulnerability from nvd – Published: 2019-12-12 19:08 – Updated: 2024-08-05 01:54
    VLAI
    Summary
    A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) does not properly limit its capabilities to the specified purpose. In conjunction with CVE-2019-18341, an unauthenticated remote attacker with network access to the CCS server could exploit this vulnerability to read or delete arbitrary files, or access other resources on the same server.
    CWE
    • CWE-749 - Exposed Dangerous Method or Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    Siemens Control Center Server (CCS) Affected: All versions < V1.5.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T01:54:13.423Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Control Center Server (CCS)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V1.5.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server\n(CCS) does not properly limit its capabilities to the specified purpose.\n\nIn conjunction with CVE-2019-18341, an unauthenticated remote attacker with\nnetwork access to the CCS server could exploit this vulnerability\nto read or delete arbitrary files, or access other resources on the same\nserver."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:F/RL:U/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-749",
                  "description": "CWE-749: Exposed Dangerous Method or Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-09T09:56:17.087Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-18342",
        "datePublished": "2019-12-12T19:08:49.000Z",
        "dateReserved": "2019-10-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T01:54:13.423Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-18342 (GCVE-0-2019-18342)

    Vulnerability from cvelistv5 – Published: 2019-12-12 19:08 – Updated: 2024-08-05 01:54
    VLAI
    Summary
    A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) does not properly limit its capabilities to the specified purpose. In conjunction with CVE-2019-18341, an unauthenticated remote attacker with network access to the CCS server could exploit this vulnerability to read or delete arbitrary files, or access other resources on the same server.
    CWE
    • CWE-749 - Exposed Dangerous Method or Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    Siemens Control Center Server (CCS) Affected: All versions < V1.5.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T01:54:13.423Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Control Center Server (CCS)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V1.5.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server\n(CCS) does not properly limit its capabilities to the specified purpose.\n\nIn conjunction with CVE-2019-18341, an unauthenticated remote attacker with\nnetwork access to the CCS server could exploit this vulnerability\nto read or delete arbitrary files, or access other resources on the same\nserver."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:F/RL:U/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-749",
                  "description": "CWE-749: Exposed Dangerous Method or Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-09T09:56:17.087Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-18342",
        "datePublished": "2019-12-12T19:08:49.000Z",
        "dateReserved": "2019-10-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T01:54:13.423Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }