CVE-2025-40898 (GCVE-0-2025-40898)

Vulnerability from nvd – Published: 2025-12-18 13:19 – Updated: 2025-12-18 14:19
VLAI?
Title
Path traversal in Import Arc data archive functionality in Guardian/CMC before 25.5.0
Summary
A path traversal vulnerability was discovered in the Import Arc data archive functionality due to insufficient validation of the input file. An authenticated user with limited privileges, by uploading a specifically-crafted Arc data archive, can potentially write arbitrary files in arbitrary paths, altering the device configuration and/or affecting its availability.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40898",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-18T14:18:25.431326Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-18T14:19:23.988Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-12-18T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A path traversal vulnerability was discovered in the Import Arc data archive functionality due to insufficient validation of the input file. An authenticated user with limited privileges, by uploading a specifically-crafted Arc data archive, can potentially write arbitrary files in arbitrary paths, altering the device configuration and/or affecting its availability."
            }
          ],
          "value": "A path traversal vulnerability was discovered in the Import Arc data archive functionality due to insufficient validation of the input file. An authenticated user with limited privileges, by uploading a specifically-crafted Arc data archive, can potentially write arbitrary files in arbitrary paths, altering the device configuration and/or affecting its availability."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-139",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-139 Relative Path Traversal"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-18T13:19:22.192Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:15-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v25.5.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v25.5.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Path traversal in Import Arc data archive functionality in Guardian/CMC before 25.5.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40898",
    "datePublished": "2025-12-18T13:19:22.192Z",
    "dateReserved": "2025-04-16T09:04:35.922Z",
    "dateUpdated": "2025-12-18T14:19:23.988Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-40893 (GCVE-0-2025-40893)

Vulnerability from nvd – Published: 2025-12-18 13:17 – Updated: 2025-12-18 14:21
VLAI?
Title
HTML injection in Asset List in Guardian/CMC before 25.5.0
Summary
A Stored HTML Injection vulnerability was discovered in the Asset List functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets to inject HTML tags into asset attributes. When a victim views the affected assets in the Asset List (and similar functions), the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
Credits
This issue was found by Stefano Libero of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40893",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-18T14:20:22.618000Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-18T14:21:28.172Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Stefano Libero of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-12-18T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A Stored HTML Injection vulnerability was discovered in the Asset List functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets to inject HTML tags into asset attributes. When a victim views the affected assets in the Asset List (and similar functions), the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
            }
          ],
          "value": "A Stored HTML Injection vulnerability was discovered in the Asset List functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets to inject HTML tags into asset attributes. When a victim views the affected assets in the Asset List (and similar functions), the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-18T13:17:54.241Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:14-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v25.5.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v25.5.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "HTML injection in Asset List in Guardian/CMC before 25.5.0",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40893",
    "datePublished": "2025-12-18T13:17:54.241Z",
    "dateReserved": "2025-04-16T09:04:25.007Z",
    "dateUpdated": "2025-12-18T14:21:28.172Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-40892 (GCVE-0-2025-40892)

Vulnerability from nvd – Published: 2025-12-18 13:16 – Updated: 2025-12-18 14:30
VLAI?
Title
Stored Cross-Site Scripting (XSS) in Reports in Guardian/CMC before 25.5.0
Summary
A Stored Cross-Site Scripting vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing a JavaScript payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
Credits
This issue was found by Stefano Libero of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40892",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-18T14:30:40.652705Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-18T14:30:50.600Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Stefano Libero of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-12-18T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A Stored Cross-Site Scripting vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing a JavaScript payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information."
            }
          ],
          "value": "A Stored Cross-Site Scripting vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing a JavaScript payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:L/VI:H/VA:H/SC:L/SI:L/SA:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.9,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-18T13:16:25.212Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:13-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v25.5.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v25.5.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Stored Cross-Site Scripting (XSS) in Reports in Guardian/CMC before 25.5.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eReview existing report templates.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Review existing report templates."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40892",
    "datePublished": "2025-12-18T13:16:25.212Z",
    "dateReserved": "2025-04-16T09:04:25.007Z",
    "dateUpdated": "2025-12-18T14:30:50.600Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-40891 (GCVE-0-2025-40891)

Vulnerability from nvd – Published: 2025-12-18 13:14 – Updated: 2025-12-18 14:32
VLAI?
Title
HTML injection in in Time Machine functionality in Guardian/CMC before 25.5.0
Summary
A Stored HTML Injection vulnerability was discovered in the Time Machine Snapshot Diff functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets at two different times to inject HTML tags into asset attributes across two snapshots. Exploitation requires a victim to use the Time Machine Snapshot Diff feature on those specific snapshots and perform specific GUI actions, at which point the injected HTML renders in their browser, enabling phishing and open redirect attacks. Full XSS exploitation is prevented by input validation and Content Security Policy. Attack complexity is high due to multiple required conditions.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
Credits
This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40891",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-18T14:31:41.787585Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-18T14:32:26.508Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-12-18T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A Stored HTML Injection vulnerability was discovered in the Time Machine Snapshot Diff functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets at two different times to inject HTML tags into asset attributes across two snapshots. Exploitation requires a victim to use the Time Machine Snapshot Diff feature on those specific snapshots and perform specific GUI actions, at which point the injected HTML renders in their browser, enabling phishing and open redirect attacks. Full XSS exploitation is prevented by input validation and Content Security Policy. Attack complexity is high due to multiple required conditions."
            }
          ],
          "value": "A Stored HTML Injection vulnerability was discovered in the Time Machine Snapshot Diff functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets at two different times to inject HTML tags into asset attributes across two snapshots. Exploitation requires a victim to use the Time Machine Snapshot Diff feature on those specific snapshots and perform specific GUI actions, at which point the injected HTML renders in their browser, enabling phishing and open redirect attacks. Full XSS exploitation is prevented by input validation and Content Security Policy. Attack complexity is high due to multiple required conditions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 2.3,
            "baseSeverity": "LOW",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-18T13:14:35.366Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:12-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v25.5.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v25.5.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "HTML injection in in Time Machine functionality in Guardian/CMC before 25.5.0",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40891",
    "datePublished": "2025-12-18T13:14:35.366Z",
    "dateReserved": "2025-04-16T09:04:25.006Z",
    "dateUpdated": "2025-12-18T14:32:26.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-40889 (GCVE-0-2025-40889)

Vulnerability from nvd – Published: 2025-10-07 12:37 – Updated: 2025-10-07 13:08
VLAI?
Title
Path traversal in Time Machine functionality in Guardian/CMC before 25.2.0
Summary
A path traversal vulnerability was discovered in the Time Machine functionality due to missing validation of two input parameters. An authenticated user with limited privileges, by issuing a specifically-crafted request, can potentially alter the structure and content of files in the /data folder, and/or affect their availability.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40889",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:08:45.959519Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:08:57.420Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A path traversal vulnerability was discovered in the Time Machine functionality due to missing validation of two input parameters. An authenticated user with limited privileges, by issuing a specifically-crafted request, can potentially alter the structure and content of files in the /data folder, and/or affect their availability."
            }
          ],
          "value": "A path traversal vulnerability was discovered in the Time Machine functionality due to missing validation of two input parameters. An authenticated user with limited privileges, by issuing a specifically-crafted request, can potentially alter the structure and content of files in the /data folder, and/or affect their availability."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-139",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-139 Relative Path Traversal"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:37:58.635Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:9-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Path traversal in Time Machine functionality in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40889",
    "datePublished": "2025-10-07T12:37:58.635Z",
    "dateReserved": "2025-04-16T09:04:16.894Z",
    "dateUpdated": "2025-10-07T13:08:57.420Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40888 (GCVE-0-2025-40888)

Vulnerability from nvd – Published: 2025-10-07 12:38 – Updated: 2025-10-07 13:08
VLAI?
Title
Authenticated SQL Injection on CLI functionality in Guardian/CMC before 25.3.0
Summary
A SQL Injection vulnerability was discovered in the CLI functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.3.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.3.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40888",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:07:52.204458Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:08:15.336Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A SQL Injection vulnerability was discovered in the CLI functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
            }
          ],
          "value": "A SQL Injection vulnerability was discovered in the CLI functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:38:39.042Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:10-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.3.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.3.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Authenticated SQL Injection on CLI functionality in Guardian/CMC before 25.3.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40888",
    "datePublished": "2025-10-07T12:38:39.042Z",
    "dateReserved": "2025-04-16T09:04:16.894Z",
    "dateUpdated": "2025-10-07T13:08:15.336Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40887 (GCVE-0-2025-40887)

Vulnerability from nvd – Published: 2025-10-07 12:37 – Updated: 2025-10-07 13:09
VLAI?
Title
Authenticated SQL Injection on Alert functionality in Guardian/CMC before 25.2.0
Summary
A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40887",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:09:15.993526Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:09:33.674Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
            }
          ],
          "value": "A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:37:10.142Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:8-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Authenticated SQL Injection on Alert functionality in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40887",
    "datePublished": "2025-10-07T12:37:10.142Z",
    "dateReserved": "2025-04-16T09:04:16.894Z",
    "dateUpdated": "2025-10-07T13:09:33.674Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40886 (GCVE-0-2025-40886)

Vulnerability from nvd – Published: 2025-10-07 12:36 – Updated: 2025-10-07 13:10
VLAI?
Title
Authenticated SQL Injection on Alert functionality in Guardian/CMC before 25.2.0
Summary
A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SQL statements on the DBMS used by the web application, potentially exposing unauthorized data, altering their structure and content, and/or affecting their availability.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40886",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:09:56.120105Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:10:08.763Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SQL statements on the DBMS used by the web application, potentially exposing unauthorized data, altering their structure and content, and/or affecting their availability."
            }
          ],
          "value": "A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SQL statements on the DBMS used by the web application, potentially exposing unauthorized data, altering their structure and content, and/or affecting their availability."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:36:34.324Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:7-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Authenticated SQL Injection on Alert functionality in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40886",
    "datePublished": "2025-10-07T12:36:34.324Z",
    "dateReserved": "2025-04-16T09:04:16.894Z",
    "dateUpdated": "2025-10-07T13:10:08.763Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40885 (GCVE-0-2025-40885)

Vulnerability from nvd – Published: 2025-10-07 12:35 – Updated: 2025-10-07 13:35
VLAI?
Title
Authenticated SQL Injection on Smart Polling functionality in Guardian/CMC before 25.2.0
Summary
A SQL Injection vulnerability was discovered in the Smart Polling functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40885",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:35:06.915258Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:35:18.140Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A SQL Injection vulnerability was discovered in the Smart Polling functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
            }
          ],
          "value": "A SQL Injection vulnerability was discovered in the Smart Polling functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:35:57.566Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:6-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Authenticated SQL Injection on Smart Polling functionality in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40885",
    "datePublished": "2025-10-07T12:35:57.566Z",
    "dateReserved": "2025-04-16T09:04:16.893Z",
    "dateUpdated": "2025-10-07T13:35:18.140Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3719 (GCVE-0-2025-3719)

Vulnerability from nvd – Published: 2025-10-07 12:34 – Updated: 2025-10-07 13:19
VLAI?
Title
Incorrect authorization for CLI in Guardian/CMC before 25.2.0
Summary
An access control vulnerability was discovered in the CLI functionality due to a specific access restriction not being properly enforced for users with limited privileges. An authenticated user with limited privileges can issue administrative CLI commands, altering the device configuration, and/or affecting its availability.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3719",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:19:15.431397Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:19:30.875Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An access control vulnerability was discovered in the CLI functionality due to a specific access restriction not being properly enforced for users with limited privileges. An authenticated user with limited privileges can issue administrative CLI commands, altering the device configuration, and/or affecting its availability."
            }
          ],
          "value": "An access control vulnerability was discovered in the CLI functionality due to a specific access restriction not being properly enforced for users with limited privileges. An authenticated user with limited privileges can issue administrative CLI commands, altering the device configuration, and/or affecting its availability."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-122",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-122 Privilege Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863 Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:34:46.613Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:5-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Incorrect authorization for CLI in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-3719",
    "datePublished": "2025-10-07T12:34:46.613Z",
    "dateReserved": "2025-04-16T09:04:09.395Z",
    "dateUpdated": "2025-10-07T13:19:30.875Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3718 (GCVE-0-2025-3718)

Vulnerability from nvd – Published: 2025-10-07 12:33 – Updated: 2025-10-07 13:21
VLAI?
Title
Client-side path traversal in Guardian/CMC before 25.2.0
Summary
A client-side path traversal vulnerability was discovered in the web management interface front-end due to missing validation of an input parameter. An authenticated user with limited privileges can craft a malicious URL which, if visited by an authenticated victim, leads to a Cross-Site Scripting (XSS) attack.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3718",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:20:21.499345Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:21:49.093Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A client-side path traversal vulnerability was discovered in the web management interface front-end due to missing validation of an input parameter. An authenticated user with limited privileges can craft a malicious URL which, if visited by an authenticated victim, leads to a Cross-Site Scripting (XSS) attack."
            }
          ],
          "value": "A client-side path traversal vulnerability was discovered in the web management interface front-end due to missing validation of an input parameter. An authenticated user with limited privileges can craft a malicious URL which, if visited by an authenticated victim, leads to a Cross-Site Scripting (XSS) attack."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-63",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-63 Cross-Site Scripting (XSS)"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:A/VC:L/VI:H/VA:H/SC:L/SI:L/SA:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.9,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:33:18.231Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:4-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Client-side path traversal in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Apply care when opening untrusted links or visiting external websites while an authenticated session to the web management interface is established.\u003cbr\u003e"
            }
          ],
          "value": "Apply care when opening untrusted links or visiting external websites while an authenticated session to the web management interface is established."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-3718",
    "datePublished": "2025-10-07T12:33:18.231Z",
    "dateReserved": "2025-04-16T09:04:05.707Z",
    "dateUpdated": "2025-10-07T13:21:49.093Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4465 (GCVE-0-2024-4465)

Vulnerability from nvd – Published: 2024-09-11 14:45 – Updated: 2024-09-20 12:21
VLAI?
Title
Incorrect authorization for Reports configuration in Guardian/CMC before 24.2.0
Summary
An access control vulnerability was discovered in the Reports section due to a specific access restriction not being properly enforced for users with limited privileges. If a logged-in user with reporting privileges learns how to create a specific application request, they might be able to make limited changes to the reporting configuration. This could result in a partial loss of data integrity. In Guardian/CMC instances with a reporting configuration, there could be limited Denial of Service (DoS) impacts, as the reports may not reach their intended destination, and there could also be limited information disclosure impacts. Furthermore, modifying the destination SMTP server for the reports could lead to the compromise of external credentials, as they might be sent to an unauthorized server. This could expand the scope of the attack.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 24.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 24.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Stefano Libero of Nozomi Networks Product Security team during a scheduled internal VAPT testing session.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4465",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-11T18:22:06.291130Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-11T18:22:21.182Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "24.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "24.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Stefano Libero of Nozomi Networks Product Security team during a scheduled internal VAPT testing session."
        }
      ],
      "datePublic": "2024-09-11T09:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eAn access control vulnerability was discovered in the Reports section due to a specific access restriction not being properly enforced for users with limited privileges.\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003eIf a logged-in user with reporting privileges learns how to create a specific application request, they might be able to make limited changes to the reporting configuration. This could result in a partial loss of data integrity. In Guardian/CMC instances with a reporting configuration, there could be limited Denial of Service (DoS) impacts, as the reports may not reach their intended destination, and there could also be limited information disclosure impacts. Furthermore, modifying the destination SMTP server for the reports could lead to the compromise of external credentials, as they might be sent to an unauthorized server. This could expand the scope of the attack.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "An access control vulnerability was discovered in the Reports section due to a specific access restriction not being properly enforced for users with limited privileges.\n\n\n\nIf a logged-in user with reporting privileges learns how to create a specific application request, they might be able to make limited changes to the reporting configuration. This could result in a partial loss of data integrity. In Guardian/CMC instances with a reporting configuration, there could be limited Denial of Service (DoS) impacts, as the reports may not reach their intended destination, and there could also be limited information disclosure impacts. Furthermore, modifying the destination SMTP server for the reports could lead to the compromise of external credentials, as they might be sent to an unauthorized server. This could expand the scope of the attack."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-122",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-122 Privilege Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:L/VI:L/VA:L/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863 Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-20T12:21:58.811Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2024:2-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v24.2.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v24.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Incorrect authorization for Reports configuration in Guardian/CMC before 24.2.0",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2024-4465",
    "datePublished": "2024-09-11T14:45:21.671Z",
    "dateReserved": "2024-05-03T08:33:02.980Z",
    "dateUpdated": "2024-09-20T12:21:58.811Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-5253 (GCVE-0-2023-5253)

Vulnerability from nvd – Published: 2024-01-15 10:53 – Updated: 2025-06-17 21:09
VLAI?
Title
Check Point IoT integration: WebSocket returns assets data without authentication in Guardian/CMC before 23.3.0
Summary
A missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication. Malicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 23.3.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 23.3.0 (semver)
Create a notification for this product.
Credits
This issue was found by Nozomi Networks Product Security team during an internal VAPT testing session.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:52:08.520Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.nozominetworks.com/NN-2023:12-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-5253",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-16T16:05:53.153585Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-17T21:09:23.231Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "23.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "23.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "This issue was found by Nozomi Networks Product Security team during an internal VAPT testing session."
        }
      ],
      "datePublic": "2024-01-15T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eA missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication.\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003eMalicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "A missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication.\n\n\n\nMalicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-20T11:38:34.932Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2023:12-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v23.3.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v23.3.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Check Point IoT integration: WebSocket returns assets data without authentication in Guardian/CMC before 23.3.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUse internal firewall features to limit access to the web management interface.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2023-5253",
    "datePublished": "2024-01-15T10:53:56.305Z",
    "dateReserved": "2023-09-28T12:41:27.922Z",
    "dateUpdated": "2025-06-17T21:09:23.231Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-32649 (GCVE-0-2023-32649)

Vulnerability from nvd – Published: 2023-09-19 10:06 – Updated: 2025-02-27 20:49
VLAI?
Title
DoS on IDS parsing of malformed asset fields in Guardian/CMC >= 22.6.0 before 22.6.3 and 23.1.0
Summary
A Denial of Service (Dos) vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields used in the Asset Intelligence functionality of our IDS, allows an unauthenticated attacker to crash the IDS module by sending specially crafted malformed network packets. During the (limited) time window before the IDS module is automatically restarted, network traffic may not be analyzed.
CWE
  • CWE-1286 - Improper Validation of Syntactic Correctness of Input
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 22.6.0 , < 22.6.3 (semver)
Affected: 23.0.0 , < 23.1.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 22.6.0 , < 22.6.3 (semver)
Affected: 23.0.0 , < 23.1.0 (semver)
Create a notification for this product.
Credits
This issue was found by Nozomi Networks during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:25:36.692Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.nozominetworks.com/NN-2023:10-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-32649",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T21:50:16.637812Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T20:49:35.570Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "22.6.3",
              "status": "affected",
              "version": "22.6.0",
              "versionType": "semver"
            },
            {
              "lessThan": "23.1.0",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "22.6.3",
              "status": "affected",
              "version": "22.6.0",
              "versionType": "semver"
            },
            {
              "lessThan": "23.1.0",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "This issue was found by Nozomi Networks during an internal investigation."
        }
      ],
      "datePublic": "2023-09-18T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eA Denial of Service (Dos) vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields used in the Asset Intelligence functionality of our IDS, allows an unauthenticated attacker to crash the IDS module by sending specially crafted malformed network packets.\u003c/div\u003e\u003cdiv\u003eDuring the (limited) time window before the IDS module is automatically restarted, network traffic may not be analyzed.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "A Denial of Service (Dos) vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields used in the Asset Intelligence functionality of our IDS, allows an unauthenticated attacker to crash the IDS module by sending specially crafted malformed network packets.\n\nDuring the (limited) time window before the IDS module is automatically restarted, network traffic may not be analyzed."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-607",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-607 Obstruction"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1286",
              "description": "CWE-1286 Improper Validation of Syntactic Correctness of Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-20T10:42:46.786Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2023:10-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v22.6.3, v23.1.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v22.6.3, v23.1.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "DoS on IDS parsing of malformed asset fields in Guardian/CMC \u003e= 22.6.0 before 22.6.3 and 23.1.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eN/A. It is recommended to monitor the IDS log to check for abnormal stops and restarts.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "N/A. It is recommended to monitor the IDS log to check for abnormal stops and restarts."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2023-32649",
    "datePublished": "2023-09-19T10:06:15.601Z",
    "dateReserved": "2023-06-12T09:20:58.638Z",
    "dateUpdated": "2025-02-27T20:49:35.570Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-2567 (GCVE-0-2023-2567)

Vulnerability from nvd – Published: 2023-09-19 10:03 – Updated: 2025-02-27 20:49
VLAI?
Title
Authenticated SQL Injection on Query functionality in Guardian/CMC before 22.6.3 and 23.1.0
Summary
A SQL Injection vulnerability has been found in Nozomi Networks Guardian and CMC, due to improper input validation in certain parameters used in the Query functionality. Authenticated users may be able to execute arbitrary SQL statements on the DBMS used by the web application.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 22.6.3 (semver)
Affected: 23.0.0 , < 23.1.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 22.6.3 (semver)
Affected: 23.0.0 , < 23.1.0 (semver)
Create a notification for this product.
Credits
This issue was found by Mostafa Soliman of IBM X-Force Red during a VAPT testing session commissioned by one of our customers.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:26:09.695Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.nozominetworks.com/NN-2023:9-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-2567",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T21:51:04.414019Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T20:49:49.077Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "22.6.3",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "23.1.0",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "22.6.3",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "23.1.0",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "This issue was found by Mostafa Soliman of IBM X-Force Red during a VAPT testing session commissioned by one of our customers."
        }
      ],
      "datePublic": "2023-09-18T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eA SQL Injection vulnerability has been found in Nozomi Networks Guardian and CMC, due to improper input validation in certain parameters used in the Query functionality.\u003cbr\u003eAuthenticated users may be able to execute arbitrary SQL statements on the DBMS used by the web application.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "A SQL Injection vulnerability has been found in Nozomi Networks Guardian and CMC, due to improper input validation in certain parameters used in the Query functionality.\nAuthenticated users may be able to execute arbitrary SQL statements on the DBMS used by the web application."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-20T12:17:25.494Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2023:9-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v22.6.3, v23.1.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v22.6.3, v23.1.0 or later."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Authenticated SQL Injection on Query functionality in Guardian/CMC before 22.6.3 and 23.1.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUse internal firewall features to limit access to the web management interface.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2023-2567",
    "datePublished": "2023-09-19T10:03:04.013Z",
    "dateReserved": "2023-05-08T08:20:28.150Z",
    "dateUpdated": "2025-02-27T20:49:49.077Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-29245 (GCVE-0-2023-29245)

Vulnerability from nvd – Published: 2023-09-19 10:04 – Updated: 2025-02-27 20:49
VLAI?
Title
SQL Injection on IDS parsing of malformed asset fields in Guardian/CMC >= 22.6.0 before 22.6.3 and 23.1.0
Summary
A SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields used in the Asset Intelligence functionality of our IDS, may allow an unauthenticated attacker to execute arbitrary SQL statements on the DBMS used by the web application by sending specially crafted malicious network packets. Malicious users with extensive knowledge on the underlying system may be able to extract arbitrary information from the DBMS in an uncontrolled way, alter its structure and data, and/or affect its availability.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 22.6.0 , < 22.6.3 (semver)
Affected: 23.0.0 , < 23.1.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 22.6.0 , < 22.6.3 (semver)
Affected: 23.0.0 , < 23.1.0 (semver)
Create a notification for this product.
Credits
This issue was found by Nozomi Networks during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:16.066Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.nozominetworks.com/NN-2023:11-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-29245",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T21:51:02.783106Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T20:49:42.741Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "22.6.3",
              "status": "affected",
              "version": "22.6.0",
              "versionType": "semver"
            },
            {
              "lessThan": "23.1.0",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "22.6.3",
              "status": "affected",
              "version": "22.6.0",
              "versionType": "semver"
            },
            {
              "lessThan": "23.1.0",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "This issue was found by Nozomi Networks during an internal investigation."
        }
      ],
      "datePublic": "2023-09-18T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eA SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields used in the Asset Intelligence functionality of our IDS, may allow an unauthenticated attacker to execute arbitrary SQL statements on the DBMS used by the web application by sending specially crafted malicious network packets.\u003c/div\u003e\u003cdiv\u003eMalicious users with extensive knowledge on the underlying system may be able to extract arbitrary information from the DBMS in an uncontrolled way, alter its structure and data, and/or affect its availability.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "A SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields used in the Asset Intelligence functionality of our IDS, may allow an unauthenticated attacker to execute arbitrary SQL statements on the DBMS used by the web application by sending specially crafted malicious network packets.\n\nMalicious users with extensive knowledge on the underlying system may be able to extract arbitrary information from the DBMS in an uncontrolled way, alter its structure and data, and/or affect its availability."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 9.2,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-20T10:48:14.678Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2023:11-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v22.6.3, v23.1.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v22.6.3, v23.1.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "SQL Injection on IDS parsing of malformed asset fields in Guardian/CMC \u003e= 22.6.0 before 22.6.3 and 23.1.0",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2023-29245",
    "datePublished": "2023-09-19T10:04:57.213Z",
    "dateReserved": "2023-06-12T09:20:58.631Z",
    "dateUpdated": "2025-02-27T20:49:42.741Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40898 (GCVE-0-2025-40898)

Vulnerability from cvelistv5 – Published: 2025-12-18 13:19 – Updated: 2025-12-18 14:19
VLAI?
Title
Path traversal in Import Arc data archive functionality in Guardian/CMC before 25.5.0
Summary
A path traversal vulnerability was discovered in the Import Arc data archive functionality due to insufficient validation of the input file. An authenticated user with limited privileges, by uploading a specifically-crafted Arc data archive, can potentially write arbitrary files in arbitrary paths, altering the device configuration and/or affecting its availability.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40898",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-18T14:18:25.431326Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-18T14:19:23.988Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-12-18T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A path traversal vulnerability was discovered in the Import Arc data archive functionality due to insufficient validation of the input file. An authenticated user with limited privileges, by uploading a specifically-crafted Arc data archive, can potentially write arbitrary files in arbitrary paths, altering the device configuration and/or affecting its availability."
            }
          ],
          "value": "A path traversal vulnerability was discovered in the Import Arc data archive functionality due to insufficient validation of the input file. An authenticated user with limited privileges, by uploading a specifically-crafted Arc data archive, can potentially write arbitrary files in arbitrary paths, altering the device configuration and/or affecting its availability."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-139",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-139 Relative Path Traversal"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-18T13:19:22.192Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:15-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v25.5.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v25.5.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Path traversal in Import Arc data archive functionality in Guardian/CMC before 25.5.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40898",
    "datePublished": "2025-12-18T13:19:22.192Z",
    "dateReserved": "2025-04-16T09:04:35.922Z",
    "dateUpdated": "2025-12-18T14:19:23.988Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-40893 (GCVE-0-2025-40893)

Vulnerability from cvelistv5 – Published: 2025-12-18 13:17 – Updated: 2025-12-18 14:21
VLAI?
Title
HTML injection in Asset List in Guardian/CMC before 25.5.0
Summary
A Stored HTML Injection vulnerability was discovered in the Asset List functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets to inject HTML tags into asset attributes. When a victim views the affected assets in the Asset List (and similar functions), the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
Credits
This issue was found by Stefano Libero of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40893",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-18T14:20:22.618000Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-18T14:21:28.172Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Stefano Libero of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-12-18T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A Stored HTML Injection vulnerability was discovered in the Asset List functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets to inject HTML tags into asset attributes. When a victim views the affected assets in the Asset List (and similar functions), the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
            }
          ],
          "value": "A Stored HTML Injection vulnerability was discovered in the Asset List functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets to inject HTML tags into asset attributes. When a victim views the affected assets in the Asset List (and similar functions), the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-18T13:17:54.241Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:14-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v25.5.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v25.5.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "HTML injection in Asset List in Guardian/CMC before 25.5.0",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40893",
    "datePublished": "2025-12-18T13:17:54.241Z",
    "dateReserved": "2025-04-16T09:04:25.007Z",
    "dateUpdated": "2025-12-18T14:21:28.172Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-40892 (GCVE-0-2025-40892)

Vulnerability from cvelistv5 – Published: 2025-12-18 13:16 – Updated: 2025-12-18 14:30
VLAI?
Title
Stored Cross-Site Scripting (XSS) in Reports in Guardian/CMC before 25.5.0
Summary
A Stored Cross-Site Scripting vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing a JavaScript payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
Credits
This issue was found by Stefano Libero of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40892",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-18T14:30:40.652705Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-18T14:30:50.600Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Stefano Libero of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-12-18T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A Stored Cross-Site Scripting vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing a JavaScript payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information."
            }
          ],
          "value": "A Stored Cross-Site Scripting vulnerability was discovered in the Reports functionality due to improper validation of an input parameter. An authenticated user with report privileges can define a malicious report containing a JavaScript payload, or a victim can be socially engineered to import a malicious report template. When the victim views or imports the report, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:L/VI:H/VA:H/SC:L/SI:L/SA:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.9,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-18T13:16:25.212Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:13-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v25.5.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v25.5.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Stored Cross-Site Scripting (XSS) in Reports in Guardian/CMC before 25.5.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eReview existing report templates.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Review existing report templates."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40892",
    "datePublished": "2025-12-18T13:16:25.212Z",
    "dateReserved": "2025-04-16T09:04:25.007Z",
    "dateUpdated": "2025-12-18T14:30:50.600Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-40891 (GCVE-0-2025-40891)

Vulnerability from cvelistv5 – Published: 2025-12-18 13:14 – Updated: 2025-12-18 14:32
VLAI?
Title
HTML injection in in Time Machine functionality in Guardian/CMC before 25.5.0
Summary
A Stored HTML Injection vulnerability was discovered in the Time Machine Snapshot Diff functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets at two different times to inject HTML tags into asset attributes across two snapshots. Exploitation requires a victim to use the Time Machine Snapshot Diff feature on those specific snapshots and perform specific GUI actions, at which point the injected HTML renders in their browser, enabling phishing and open redirect attacks. Full XSS exploitation is prevented by input validation and Content Security Policy. Attack complexity is high due to multiple required conditions.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.5.0 (semver)
Create a notification for this product.
Credits
This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40891",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-18T14:31:41.787585Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-18T14:32:26.508Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "25.5.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-12-18T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A Stored HTML Injection vulnerability was discovered in the Time Machine Snapshot Diff functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets at two different times to inject HTML tags into asset attributes across two snapshots. Exploitation requires a victim to use the Time Machine Snapshot Diff feature on those specific snapshots and perform specific GUI actions, at which point the injected HTML renders in their browser, enabling phishing and open redirect attacks. Full XSS exploitation is prevented by input validation and Content Security Policy. Attack complexity is high due to multiple required conditions."
            }
          ],
          "value": "A Stored HTML Injection vulnerability was discovered in the Time Machine Snapshot Diff functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets at two different times to inject HTML tags into asset attributes across two snapshots. Exploitation requires a victim to use the Time Machine Snapshot Diff feature on those specific snapshots and perform specific GUI actions, at which point the injected HTML renders in their browser, enabling phishing and open redirect attacks. Full XSS exploitation is prevented by input validation and Content Security Policy. Attack complexity is high due to multiple required conditions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 2.3,
            "baseSeverity": "LOW",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-18T13:14:35.366Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:12-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v25.5.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v25.5.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "HTML injection in in Time Machine functionality in Guardian/CMC before 25.5.0",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40891",
    "datePublished": "2025-12-18T13:14:35.366Z",
    "dateReserved": "2025-04-16T09:04:25.006Z",
    "dateUpdated": "2025-12-18T14:32:26.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-40888 (GCVE-0-2025-40888)

Vulnerability from cvelistv5 – Published: 2025-10-07 12:38 – Updated: 2025-10-07 13:08
VLAI?
Title
Authenticated SQL Injection on CLI functionality in Guardian/CMC before 25.3.0
Summary
A SQL Injection vulnerability was discovered in the CLI functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.3.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.3.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40888",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:07:52.204458Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:08:15.336Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A SQL Injection vulnerability was discovered in the CLI functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
            }
          ],
          "value": "A SQL Injection vulnerability was discovered in the CLI functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:38:39.042Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:10-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.3.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.3.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Authenticated SQL Injection on CLI functionality in Guardian/CMC before 25.3.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40888",
    "datePublished": "2025-10-07T12:38:39.042Z",
    "dateReserved": "2025-04-16T09:04:16.894Z",
    "dateUpdated": "2025-10-07T13:08:15.336Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40889 (GCVE-0-2025-40889)

Vulnerability from cvelistv5 – Published: 2025-10-07 12:37 – Updated: 2025-10-07 13:08
VLAI?
Title
Path traversal in Time Machine functionality in Guardian/CMC before 25.2.0
Summary
A path traversal vulnerability was discovered in the Time Machine functionality due to missing validation of two input parameters. An authenticated user with limited privileges, by issuing a specifically-crafted request, can potentially alter the structure and content of files in the /data folder, and/or affect their availability.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40889",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:08:45.959519Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:08:57.420Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A path traversal vulnerability was discovered in the Time Machine functionality due to missing validation of two input parameters. An authenticated user with limited privileges, by issuing a specifically-crafted request, can potentially alter the structure and content of files in the /data folder, and/or affect their availability."
            }
          ],
          "value": "A path traversal vulnerability was discovered in the Time Machine functionality due to missing validation of two input parameters. An authenticated user with limited privileges, by issuing a specifically-crafted request, can potentially alter the structure and content of files in the /data folder, and/or affect their availability."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-139",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-139 Relative Path Traversal"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:37:58.635Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:9-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Path traversal in Time Machine functionality in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40889",
    "datePublished": "2025-10-07T12:37:58.635Z",
    "dateReserved": "2025-04-16T09:04:16.894Z",
    "dateUpdated": "2025-10-07T13:08:57.420Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40887 (GCVE-0-2025-40887)

Vulnerability from cvelistv5 – Published: 2025-10-07 12:37 – Updated: 2025-10-07 13:09
VLAI?
Title
Authenticated SQL Injection on Alert functionality in Guardian/CMC before 25.2.0
Summary
A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40887",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:09:15.993526Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:09:33.674Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
            }
          ],
          "value": "A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:37:10.142Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:8-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Authenticated SQL Injection on Alert functionality in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40887",
    "datePublished": "2025-10-07T12:37:10.142Z",
    "dateReserved": "2025-04-16T09:04:16.894Z",
    "dateUpdated": "2025-10-07T13:09:33.674Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40886 (GCVE-0-2025-40886)

Vulnerability from cvelistv5 – Published: 2025-10-07 12:36 – Updated: 2025-10-07 13:10
VLAI?
Title
Authenticated SQL Injection on Alert functionality in Guardian/CMC before 25.2.0
Summary
A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SQL statements on the DBMS used by the web application, potentially exposing unauthorized data, altering their structure and content, and/or affecting their availability.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40886",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:09:56.120105Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:10:08.763Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SQL statements on the DBMS used by the web application, potentially exposing unauthorized data, altering their structure and content, and/or affecting their availability."
            }
          ],
          "value": "A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SQL statements on the DBMS used by the web application, potentially exposing unauthorized data, altering their structure and content, and/or affecting their availability."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:36:34.324Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:7-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Authenticated SQL Injection on Alert functionality in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40886",
    "datePublished": "2025-10-07T12:36:34.324Z",
    "dateReserved": "2025-04-16T09:04:16.894Z",
    "dateUpdated": "2025-10-07T13:10:08.763Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-40885 (GCVE-0-2025-40885)

Vulnerability from cvelistv5 – Published: 2025-10-07 12:35 – Updated: 2025-10-07 13:35
VLAI?
Title
Authenticated SQL Injection on Smart Polling functionality in Guardian/CMC before 25.2.0
Summary
A SQL Injection vulnerability was discovered in the Smart Polling functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40885",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:35:06.915258Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:35:18.140Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A SQL Injection vulnerability was discovered in the Smart Polling functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
            }
          ],
          "value": "A SQL Injection vulnerability was discovered in the Smart Polling functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:35:57.566Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:6-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Authenticated SQL Injection on Smart Polling functionality in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-40885",
    "datePublished": "2025-10-07T12:35:57.566Z",
    "dateReserved": "2025-04-16T09:04:16.893Z",
    "dateUpdated": "2025-10-07T13:35:18.140Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3719 (GCVE-0-2025-3719)

Vulnerability from cvelistv5 – Published: 2025-10-07 12:34 – Updated: 2025-10-07 13:19
VLAI?
Title
Incorrect authorization for CLI in Guardian/CMC before 25.2.0
Summary
An access control vulnerability was discovered in the CLI functionality due to a specific access restriction not being properly enforced for users with limited privileges. An authenticated user with limited privileges can issue administrative CLI commands, altering the device configuration, and/or affecting its availability.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3719",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:19:15.431397Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:19:30.875Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An access control vulnerability was discovered in the CLI functionality due to a specific access restriction not being properly enforced for users with limited privileges. An authenticated user with limited privileges can issue administrative CLI commands, altering the device configuration, and/or affecting its availability."
            }
          ],
          "value": "An access control vulnerability was discovered in the CLI functionality due to a specific access restriction not being properly enforced for users with limited privileges. An authenticated user with limited privileges can issue administrative CLI commands, altering the device configuration, and/or affecting its availability."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-122",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-122 Privilege Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863 Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:34:46.613Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:5-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Incorrect authorization for CLI in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-3719",
    "datePublished": "2025-10-07T12:34:46.613Z",
    "dateReserved": "2025-04-16T09:04:09.395Z",
    "dateUpdated": "2025-10-07T13:19:30.875Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3718 (GCVE-0-2025-3718)

Vulnerability from cvelistv5 – Published: 2025-10-07 12:33 – Updated: 2025-10-07 13:21
VLAI?
Title
Client-side path traversal in Guardian/CMC before 25.2.0
Summary
A client-side path traversal vulnerability was discovered in the web management interface front-end due to missing validation of an input parameter. An authenticated user with limited privileges can craft a malicious URL which, if visited by an authenticated victim, leads to a Cross-Site Scripting (XSS) attack.
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 25.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3718",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T13:20:21.499345Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T13:21:49.093Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "25.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Stefano Libero and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2025-10-07T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A client-side path traversal vulnerability was discovered in the web management interface front-end due to missing validation of an input parameter. An authenticated user with limited privileges can craft a malicious URL which, if visited by an authenticated victim, leads to a Cross-Site Scripting (XSS) attack."
            }
          ],
          "value": "A client-side path traversal vulnerability was discovered in the web management interface front-end due to missing validation of an input parameter. An authenticated user with limited privileges can craft a malicious URL which, if visited by an authenticated victim, leads to a Cross-Site Scripting (XSS) attack."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-63",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-63 Cross-Site Scripting (XSS)"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:A/VC:L/VI:H/VA:H/SC:L/SI:L/SA:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.9,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T12:33:18.231Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2025:4-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to v25.2.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v25.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Client-side path traversal in Guardian/CMC before 25.2.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use internal firewall features to limit access to the web management interface.\u003cbr\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Review all accounts with access to it and delete unnecessary ones.\u003cbr\u003e"
            }
          ],
          "value": "Review all accounts with access to it and delete unnecessary ones."
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Apply care when opening untrusted links or visiting external websites while an authenticated session to the web management interface is established.\u003cbr\u003e"
            }
          ],
          "value": "Apply care when opening untrusted links or visiting external websites while an authenticated session to the web management interface is established."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-3718",
    "datePublished": "2025-10-07T12:33:18.231Z",
    "dateReserved": "2025-04-16T09:04:05.707Z",
    "dateUpdated": "2025-10-07T13:21:49.093Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4465 (GCVE-0-2024-4465)

Vulnerability from cvelistv5 – Published: 2024-09-11 14:45 – Updated: 2024-09-20 12:21
VLAI?
Title
Incorrect authorization for Reports configuration in Guardian/CMC before 24.2.0
Summary
An access control vulnerability was discovered in the Reports section due to a specific access restriction not being properly enforced for users with limited privileges. If a logged-in user with reporting privileges learns how to create a specific application request, they might be able to make limited changes to the reporting configuration. This could result in a partial loss of data integrity. In Guardian/CMC instances with a reporting configuration, there could be limited Denial of Service (DoS) impacts, as the reports may not reach their intended destination, and there could also be limited information disclosure impacts. Furthermore, modifying the destination SMTP server for the reports could lead to the compromise of external credentials, as they might be sent to an unauthorized server. This could expand the scope of the attack.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 24.2.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 24.2.0 (semver)
Create a notification for this product.
Credits
This issue was found by Stefano Libero of Nozomi Networks Product Security team during a scheduled internal VAPT testing session.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4465",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-11T18:22:06.291130Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-11T18:22:21.182Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "24.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "24.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Stefano Libero of Nozomi Networks Product Security team during a scheduled internal VAPT testing session."
        }
      ],
      "datePublic": "2024-09-11T09:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eAn access control vulnerability was discovered in the Reports section due to a specific access restriction not being properly enforced for users with limited privileges.\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003eIf a logged-in user with reporting privileges learns how to create a specific application request, they might be able to make limited changes to the reporting configuration. This could result in a partial loss of data integrity. In Guardian/CMC instances with a reporting configuration, there could be limited Denial of Service (DoS) impacts, as the reports may not reach their intended destination, and there could also be limited information disclosure impacts. Furthermore, modifying the destination SMTP server for the reports could lead to the compromise of external credentials, as they might be sent to an unauthorized server. This could expand the scope of the attack.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "An access control vulnerability was discovered in the Reports section due to a specific access restriction not being properly enforced for users with limited privileges.\n\n\n\nIf a logged-in user with reporting privileges learns how to create a specific application request, they might be able to make limited changes to the reporting configuration. This could result in a partial loss of data integrity. In Guardian/CMC instances with a reporting configuration, there could be limited Denial of Service (DoS) impacts, as the reports may not reach their intended destination, and there could also be limited information disclosure impacts. Furthermore, modifying the destination SMTP server for the reports could lead to the compromise of external credentials, as they might be sent to an unauthorized server. This could expand the scope of the attack."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-122",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-122 Privilege Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:L/VI:L/VA:L/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863 Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-20T12:21:58.811Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2024:2-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v24.2.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v24.2.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Incorrect authorization for Reports configuration in Guardian/CMC before 24.2.0",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2024-4465",
    "datePublished": "2024-09-11T14:45:21.671Z",
    "dateReserved": "2024-05-03T08:33:02.980Z",
    "dateUpdated": "2024-09-20T12:21:58.811Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-5253 (GCVE-0-2023-5253)

Vulnerability from cvelistv5 – Published: 2024-01-15 10:53 – Updated: 2025-06-17 21:09
VLAI?
Title
Check Point IoT integration: WebSocket returns assets data without authentication in Guardian/CMC before 23.3.0
Summary
A missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication. Malicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 0 , < 23.3.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 0 , < 23.3.0 (semver)
Create a notification for this product.
Credits
This issue was found by Nozomi Networks Product Security team during an internal VAPT testing session.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:52:08.520Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.nozominetworks.com/NN-2023:12-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-5253",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-16T16:05:53.153585Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-17T21:09:23.231Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "23.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "23.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "This issue was found by Nozomi Networks Product Security team during an internal VAPT testing session."
        }
      ],
      "datePublic": "2024-01-15T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eA missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication.\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003eMalicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "A missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication.\n\n\n\nMalicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-20T11:38:34.932Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2023:12-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v23.3.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v23.3.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Check Point IoT integration: WebSocket returns assets data without authentication in Guardian/CMC before 23.3.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUse internal firewall features to limit access to the web management interface.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Use internal firewall features to limit access to the web management interface."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2023-5253",
    "datePublished": "2024-01-15T10:53:56.305Z",
    "dateReserved": "2023-09-28T12:41:27.922Z",
    "dateUpdated": "2025-06-17T21:09:23.231Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-32649 (GCVE-0-2023-32649)

Vulnerability from cvelistv5 – Published: 2023-09-19 10:06 – Updated: 2025-02-27 20:49
VLAI?
Title
DoS on IDS parsing of malformed asset fields in Guardian/CMC >= 22.6.0 before 22.6.3 and 23.1.0
Summary
A Denial of Service (Dos) vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields used in the Asset Intelligence functionality of our IDS, allows an unauthenticated attacker to crash the IDS module by sending specially crafted malformed network packets. During the (limited) time window before the IDS module is automatically restarted, network traffic may not be analyzed.
CWE
  • CWE-1286 - Improper Validation of Syntactic Correctness of Input
Assigner
Impacted products
Vendor Product Version
Nozomi Networks Guardian Affected: 22.6.0 , < 22.6.3 (semver)
Affected: 23.0.0 , < 23.1.0 (semver)
Create a notification for this product.
    Nozomi Networks CMC Affected: 22.6.0 , < 22.6.3 (semver)
Affected: 23.0.0 , < 23.1.0 (semver)
Create a notification for this product.
Credits
This issue was found by Nozomi Networks during an internal investigation.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:25:36.692Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.nozominetworks.com/NN-2023:10-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-32649",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T21:50:16.637812Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T20:49:35.570Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "22.6.3",
              "status": "affected",
              "version": "22.6.0",
              "versionType": "semver"
            },
            {
              "lessThan": "23.1.0",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "22.6.3",
              "status": "affected",
              "version": "22.6.0",
              "versionType": "semver"
            },
            {
              "lessThan": "23.1.0",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "This issue was found by Nozomi Networks during an internal investigation."
        }
      ],
      "datePublic": "2023-09-18T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eA Denial of Service (Dos) vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields used in the Asset Intelligence functionality of our IDS, allows an unauthenticated attacker to crash the IDS module by sending specially crafted malformed network packets.\u003c/div\u003e\u003cdiv\u003eDuring the (limited) time window before the IDS module is automatically restarted, network traffic may not be analyzed.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "A Denial of Service (Dos) vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields used in the Asset Intelligence functionality of our IDS, allows an unauthenticated attacker to crash the IDS module by sending specially crafted malformed network packets.\n\nDuring the (limited) time window before the IDS module is automatically restarted, network traffic may not be analyzed."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-607",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-607 Obstruction"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1286",
              "description": "CWE-1286 Improper Validation of Syntactic Correctness of Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-20T10:42:46.786Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2023:10-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to v22.6.3, v23.1.0 or later.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to v22.6.3, v23.1.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "DoS on IDS parsing of malformed asset fields in Guardian/CMC \u003e= 22.6.0 before 22.6.3 and 23.1.0",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003eN/A. It is recommended to monitor the IDS log to check for abnormal stops and restarts.\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "N/A. It is recommended to monitor the IDS log to check for abnormal stops and restarts."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2023-32649",
    "datePublished": "2023-09-19T10:06:15.601Z",
    "dateReserved": "2023-06-12T09:20:58.638Z",
    "dateUpdated": "2025-02-27T20:49:35.570Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}