Search

Find a vulnerability

Search criteria

    59 vulnerabilities found for ac7 by tenda

    VAR-202510-0141

    Vulnerability from variot - Updated: 2025-11-18 15:35

    A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. The Tenda AC7 is a wireless router from the Chinese company Tenda. This vulnerability stems from a failure to properly validate the length of the input data in the "Password" parameter in the file /goform/fast_setting_pppoe_set. An attacker could exploit this vulnerability to execute arbitrary code or cause a denial of service (DoS) attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-0141",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24149"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11527"
          }
        ]
      },
      "cve": "CVE-2025-11527",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-11527",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-24149",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-11527",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-11527",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-24149",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24149"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11527"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. The Tenda AC7 is a wireless router from the Chinese company Tenda. This vulnerability stems from a failure to properly validate the length of the input data in the \"Password\" parameter in the file /goform/fast_setting_pppoe_set. An attacker could exploit this vulnerability to execute arbitrary code or cause a denial of service (DoS) attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11527"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24149"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-11527",
            "trust": 1.6
          },
          {
            "db": "VULDB",
            "id": "327665",
            "trust": 1.0
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24149",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24149"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11527"
          }
        ]
      },
      "id": "VAR-202510-0141",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24149"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24149"
          }
        ]
      },
      "last_update_date": "2025-11-18T15:35:16.333000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11527"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/noahze01/iot-vulnerable/blob/main/tenda/ac7/fast_setting_pppoe_set.md"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.327665"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?id.327665"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?submit.669856"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-11527"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24149"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11527"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24149"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11527"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24149"
          },
          {
            "date": "2025-10-09T03:15:31.440000",
            "db": "NVD",
            "id": "CVE-2025-11527"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24149"
          },
          {
            "date": "2025-10-14T15:16:03.673000",
            "db": "NVD",
            "id": "CVE-2025-11527"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC7 /goform/fast_setting_pppoe_set file buffer overflow vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24149"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201810-0977

    Vulnerability from variot - Updated: 2025-11-18 15:28

    An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. Tenda AC7 , AC9 ,and AC10 The firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Tenda AC7, AC9 and AC10 are all wireless router products from China Tenda.

    Tenda AC7, AC9 and AC10 have command injection vulnerabilities. The following products and versions are affected: Tenda AC7 (using firmware 15.03.06.44_CN and earlier); AC9 (using firmware 15.03.05.19(6318)_CN and earlier); AC10 (using firmware 15.03.06.23_CN and earlier)

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0977",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac10",
            "scope": "lte",
            "trust": 1.8,
            "vendor": "tenda",
            "version": "15.03.06.23_cn"
          },
          {
            "model": "ac7",
            "scope": "lte",
            "trust": 1.8,
            "vendor": "tenda",
            "version": "15.03.06.44_cn"
          },
          {
            "model": "ac9",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.19\\(6318\\)_cn"
          },
          {
            "model": "ac9",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "15.03.05.19(6318)_cn"
          },
          {
            "model": "ac7 \u003c=15.03.06.44 cn",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac10 \u003c=15.03.06.23 cn",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac9 \u003c=15.03.05.19 cn",
            "scope": null,
            "trust": 0.6,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          }
        ]
      },
      "cve": "CVE-2018-14558",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2018-14558",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2020-35174",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-124729",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2018-14558",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-14558",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-14558",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2018-14558",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-14558",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-35174",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201810-1439",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124729",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2018-14558",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input. Tenda AC7 , AC9 ,and AC10 The firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Tenda AC7, AC9 and AC10 are all wireless router products from China Tenda. \n\r\n\r\nTenda AC7, AC9 and AC10 have command injection vulnerabilities. The following products and versions are affected: Tenda AC7 (using firmware 15.03.06.44_CN and earlier); AC9 (using firmware 15.03.05.19(6318)_CN and earlier); AC10 (using firmware 15.03.06.23_CN and earlier)",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14558",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "id": "VAR-201810-0977",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          }
        ],
        "trust": 1.440988034
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          }
        ]
      },
      "last_update_date": "2025-11-18T15:28:39.538000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.tenda.com.cn/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/tenda.md"
          },
          {
            "trust": 1.0,
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=cve-2018-14558"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14558"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14558"
          },
          {
            "trust": 0.6,
            "url": "http://www.cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14558"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/78.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-06-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "date": "2018-10-30T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "date": "2018-10-30T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "date": "2018-10-31T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "date": "2019-03-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "date": "2018-10-30T18:29:00.580000",
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-06-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-35174"
          },
          {
            "date": "2019-10-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124729"
          },
          {
            "date": "2019-10-03T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14558"
          },
          {
            "date": "2019-10-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          },
          {
            "date": "2019-03-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          },
          {
            "date": "2025-11-07T19:14:06.623000",
            "db": "NVD",
            "id": "CVE-2018-14558"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Tenda Command injection vulnerability in product firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013995"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201810-1439"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-0407

    Vulnerability from variot - Updated: 2025-11-18 15:25

    A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized. The Tenda AC7 is a wireless router from the Chinese company Tenda. This vulnerability stems from the failure of the newVersion parameter in the /goform/setNotUpgrade file to properly validate the length of the input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-0407",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24152"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11586"
          }
        ]
      },
      "cve": "CVE-2025-11586",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-11586",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-24152",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-11586",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-11586",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-11586",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-11586",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-24152",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24152"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11586"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11586"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized. The Tenda AC7 is a wireless router from the Chinese company Tenda. This vulnerability stems from the failure of the newVersion parameter in the /goform/setNotUpgrade file to properly validate the length of the input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11586"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24152"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-11586",
            "trust": 1.6
          },
          {
            "db": "VULDB",
            "id": "327908",
            "trust": 1.0
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24152",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24152"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11586"
          }
        ]
      },
      "id": "VAR-202510-0407",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24152"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24152"
          }
        ]
      },
      "last_update_date": "2025-11-18T15:25:51.246000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11586"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.327908"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/noahze01/iot-vulnerable/blob/main/tenda/ac7/setnotupgrade.md"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?id.327908"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?submit.671597"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/noahze01/iot-vulnerable/blob/main/tenda/ac7/setnotupgrade.md#exploit"
          },
          {
            "trust": 1.0,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-11586"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24152"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11586"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24152"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11586"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24152"
          },
          {
            "date": "2025-10-10T21:16:06.320000",
            "db": "NVD",
            "id": "CVE-2025-11586"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24152"
          },
          {
            "date": "2025-10-20T15:50:18.450000",
            "db": "NVD",
            "id": "CVE-2025-11586"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC7 /goform/setNotUpgrade file buffer overflow vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24152"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-0256

    Vulnerability from variot - Updated: 2025-11-18 15:11

    A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC7 The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability stems from the failure to properly sanitize special characters and commands in the lanIp parameter in the file /goform/AdvSetLanip. An attacker could exploit this vulnerability to execute arbitrary commands

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-0256",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24162"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015882"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11523"
          }
        ]
      },
      "cve": "CVE-2025-11523",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-11523",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Partial",
                "baseScore": 6.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-015882",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-24162",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "LOW",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-11523",
                "impactScore": 3.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-11523",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-015882",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-11523",
                "trust": 1.0,
                "value": "Low"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-11523",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-015882",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-24162",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24162"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015882"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11523"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11523"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC7 The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability stems from the failure to properly sanitize special characters and commands in the lanIp parameter in the file /goform/AdvSetLanip. An attacker could exploit this vulnerability to execute arbitrary commands",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11523"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015882"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24162"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-11523",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "327661",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015882",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24162",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24162"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015882"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11523"
          }
        ]
      },
      "id": "VAR-202510-0256",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24162"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24162"
          }
        ]
      },
      "last_update_date": "2025-11-18T15:11:50.677000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-74",
            "trust": 1.0
          },
          {
            "problemtype": "injection (CWE-74) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Command injection (CWE-77) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015882"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11523"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/noahze01/iot-vulnerable/blob/main/tenda/ac7/advsetlanip.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.327661"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.669849"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-11523"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.327661"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24162"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015882"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11523"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24162"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015882"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11523"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24162"
          },
          {
            "date": "2025-10-14T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-015882"
          },
          {
            "date": "2025-10-09T02:15:41.403000",
            "db": "NVD",
            "id": "CVE-2025-11523"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24162"
          },
          {
            "date": "2025-10-14T07:28:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-015882"
          },
          {
            "date": "2025-10-09T22:17:03.017000",
            "db": "NVD",
            "id": "CVE-2025-11523"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Injection Vulnerability in Firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015882"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202510-0224

    Vulnerability from variot - Updated: 2025-10-20 04:10

    A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used. of AC7 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability stems from the failure of the wifi_chkHz parameter in the file /goform/WifiMacFilterSet to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-0224",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24161"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015890"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11526"
          }
        ]
      },
      "cve": "CVE-2025-11526",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-11526",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-015890",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-24161",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-11526",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-015890",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-11526",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-015890",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-24161",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24161"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015890"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11526"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used. of AC7 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability stems from the failure of the wifi_chkHz parameter in the file /goform/WifiMacFilterSet to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11526"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015890"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24161"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-11526",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "327664",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015890",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24161",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24161"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015890"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11526"
          }
        ]
      },
      "id": "VAR-202510-0224",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24161"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24161"
          }
        ]
      },
      "last_update_date": "2025-10-20T04:10:28.749000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015890"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11526"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/noahze01/iot-vulnerable/blob/main/tenda/ac7/wifimacfilterset.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.327664"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.669854"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.669861"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-11526"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.327664"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24161"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015890"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11526"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24161"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015890"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11526"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24161"
          },
          {
            "date": "2025-10-14T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-015890"
          },
          {
            "date": "2025-10-09T03:15:30.983000",
            "db": "NVD",
            "id": "CVE-2025-11526"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24161"
          },
          {
            "date": "2025-10-14T07:53:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-015890"
          },
          {
            "date": "2025-10-14T15:16:03.453000",
            "db": "NVD",
            "id": "CVE-2025-11526"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Buffer error vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015890"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202510-0237

    Vulnerability from variot - Updated: 2025-10-20 04:09

    A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. of AC7 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability stems from the failure of the upnpEn parameter in the file /goform/SetUpnpCfg to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-0237",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24153"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015891"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11525"
          }
        ]
      },
      "cve": "CVE-2025-11525",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-11525",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-015891",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-24153",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-11525",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-015891",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-11525",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-015891",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-24153",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24153"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015891"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11525"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. of AC7 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability stems from the failure of the upnpEn parameter in the file /goform/SetUpnpCfg to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11525"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015891"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24153"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-11525",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "327663",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015891",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24153",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24153"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015891"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11525"
          }
        ]
      },
      "id": "VAR-202510-0237",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24153"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24153"
          }
        ]
      },
      "last_update_date": "2025-10-20T04:09:05.091000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015891"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11525"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/noahze01/iot-vulnerable/blob/main/tenda/ac7/setupnpcfg.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.327663"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.669853"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.669860"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-11525"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.327663"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24153"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015891"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11525"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24153"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015891"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11525"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24153"
          },
          {
            "date": "2025-10-14T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-015891"
          },
          {
            "date": "2025-10-09T02:15:41.797000",
            "db": "NVD",
            "id": "CVE-2025-11525"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24153"
          },
          {
            "date": "2025-10-14T07:53:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-015891"
          },
          {
            "date": "2025-10-09T22:17:13.670000",
            "db": "NVD",
            "id": "CVE-2025-11525"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Buffer error vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015891"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202510-0368

    Vulnerability from variot - Updated: 2025-10-20 03:54

    A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. The Tenda AC7 is a wireless router from the Chinese company Tenda.

    Tenda AC7 version 15.03.06.44 suffers from a buffer overflow vulnerability. This vulnerability stems from the failure of the enable parameter in the file /goform/saveAutoQos to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-0368",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24150"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11528"
          }
        ]
      },
      "cve": "CVE-2025-11528",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-11528",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-24150",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-11528",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-11528",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-24150",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24150"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11528"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. The Tenda AC7 is a wireless router from the Chinese company Tenda. \n\nTenda AC7 version 15.03.06.44 suffers from a buffer overflow vulnerability. This vulnerability stems from the failure of the enable parameter in the file /goform/saveAutoQos to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11528"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24150"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-11528",
            "trust": 1.6
          },
          {
            "db": "VULDB",
            "id": "327666",
            "trust": 1.0
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24150",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24150"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11528"
          }
        ]
      },
      "id": "VAR-202510-0368",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24150"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24150"
          }
        ]
      },
      "last_update_date": "2025-10-20T03:54:29.004000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11528"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?id.327666"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.327666"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?submit.669859"
          },
          {
            "trust": 1.0,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/noahze01/iot-vulnerable/blob/main/tenda/ac7/saveautoqos.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-11528"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24150"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11528"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24150"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11528"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24150"
          },
          {
            "date": "2025-10-09T03:15:31.637000",
            "db": "NVD",
            "id": "CVE-2025-11528"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24150"
          },
          {
            "date": "2025-10-09T22:16:40.647000",
            "db": "NVD",
            "id": "CVE-2025-11528"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC7 /goform/saveAutoQos file buffer overflow vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24150"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-0163

    Vulnerability from variot - Updated: 2025-10-20 00:16

    A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used. The Tenda AC7 is a wireless router from the Chinese company Tenda. This vulnerability stems from the failure of the ddnsEn parameter in the /goform/SetDDNSCfg file to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-0163",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24151"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11524"
          }
        ]
      },
      "cve": "CVE-2025-11524",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-11524",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-24151",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-11524",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-11524",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-24151",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24151"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11524"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used. The Tenda AC7 is a wireless router from the Chinese company Tenda. This vulnerability stems from the failure of the ddnsEn parameter in the /goform/SetDDNSCfg file to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11524"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24151"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-11524",
            "trust": 1.6
          },
          {
            "db": "VULDB",
            "id": "327662",
            "trust": 1.0
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-24151",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24151"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11524"
          }
        ]
      },
      "id": "VAR-202510-0163",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24151"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24151"
          }
        ]
      },
      "last_update_date": "2025-10-20T00:16:27.429000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11524"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?submit.669852"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.327662"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?id.327662"
          },
          {
            "trust": 1.0,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/noahze01/iot-vulnerable/blob/main/tenda/ac7/setddnscfg.md"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-11524"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24151"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11524"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24151"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11524"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24151"
          },
          {
            "date": "2025-10-09T02:15:41.603000",
            "db": "NVD",
            "id": "CVE-2025-11524"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-17T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-24151"
          },
          {
            "date": "2025-10-09T22:16:55.567000",
            "db": "NVD",
            "id": "CVE-2025-11524"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC7 /goform/SetDDNSCfg file buffer overflow vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-24151"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202508-0745

    Vulnerability from variot - Updated: 2025-10-12 23:10

    A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. of AC7 firmware and AC18 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202508-0745",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac18",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.05.19"
          },
          {
            "model": "ac18",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015586"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9023"
          }
        ]
      },
      "cve": "CVE-2025-9023",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-9023",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-015586",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-9023",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-015586",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-9023",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-015586",
                "trust": 0.8,
                "value": "High"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015586"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9023"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. of AC7 firmware and AC18 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-9023"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015586"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-9023",
            "trust": 2.6
          },
          {
            "db": "VULDB",
            "id": "320088",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015586",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015586"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9023"
          }
        ]
      },
      "id": "VAR-202508-0745",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.40125
      },
      "last_update_date": "2025-10-12T23:10:51.809000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015586"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9023"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/zezhifu1/cve_report/blob/main/ac18/formsetschedled.md"
          },
          {
            "trust": 1.8,
            "url": "https://github.com/zezhifu1/cve_report/blob/main/ac7/formsetschedled.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.320088"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.629692"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.629696"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.320088"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-9023"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015586"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9023"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015586"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-9023"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-015586"
          },
          {
            "date": "2025-08-15T09:15:31.730000",
            "db": "NVD",
            "id": "CVE-2025-9023"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-09T08:39:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-015586"
          },
          {
            "date": "2025-10-03T15:03:22.527000",
            "db": "NVD",
            "id": "CVE-2025-9023"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 firmware and \u00a0AC18\u00a0 Buffer error vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-015586"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-1024

    Vulnerability from variot - Updated: 2025-09-18 23:17

    A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC7 is a 1200Mbps dual-band wireless router from Tenda, designed for broadband upgrades and larger homes. Detailed vulnerability details are currently unavailable

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-1024",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21362"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017246"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2891"
          }
        ]
      },
      "cve": "CVE-2024-2891",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-2891",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017246",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-21362",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-2891",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017246",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-2891",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-2891",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017246",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-21362",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21362"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017246"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2891"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2891"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC7 is a 1200Mbps dual-band wireless router from Tenda, designed for broadband upgrades and larger homes. Detailed vulnerability details are currently unavailable",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-2891"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017246"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-21362"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-2891",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "257934",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017246",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-21362",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21362"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017246"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2891"
          }
        ]
      },
      "id": "VAR-202403-1024",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21362"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21362"
          }
        ]
      },
      "last_update_date": "2025-09-18T23:17:06.837000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC7 Buffer Overflow Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/732221"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21362"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017246"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2891"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?id.257934"
          },
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?submit.300354"
          },
          {
            "trust": 1.6,
            "url": "https://vuldb.com/?ctiid.257934"
          },
          {
            "trust": 1.6,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac7/v1/formquickindex.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2891"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2024-2891/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21362"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017246"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2891"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-21362"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017246"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2891"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-15T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-21362"
          },
          {
            "date": "2025-01-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017246"
          },
          {
            "date": "2024-03-26T14:15:09.530000",
            "db": "NVD",
            "id": "CVE-2024-2891"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-21362"
          },
          {
            "date": "2025-01-23T02:24:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017246"
          },
          {
            "date": "2025-01-22T17:51:29.227000",
            "db": "NVD",
            "id": "CVE-2024-2891"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017246"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-0942

    Vulnerability from variot - Updated: 2025-09-08 23:24

    A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0942",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20548"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017294"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2900"
          }
        ]
      },
      "cve": "CVE-2024-2900",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-2900",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017294",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-20548",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-2900",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017294",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-2900",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-2900",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017294",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-20548",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20548"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017294"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2900"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2900"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-2900"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017294"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20548"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-2900",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "257943",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017294",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20548",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20548"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017294"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2900"
          }
        ]
      },
      "id": "VAR-202403-0942",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20548"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20548"
          }
        ]
      },
      "last_update_date": "2025-09-08T23:24:21.447000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC7 Buffer Overflow Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/729266"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20548"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017294"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2900"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?id.257943"
          },
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?submit.300364"
          },
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac7/v1/saveparentcontrolinfo_deviceid.md"
          },
          {
            "trust": 1.6,
            "url": "https://vuldb.com/?ctiid.257943"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2900"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2024-2900/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20548"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017294"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2900"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20548"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017294"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2900"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20548"
          },
          {
            "date": "2025-01-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017294"
          },
          {
            "date": "2024-03-26T20:15:10.500000",
            "db": "NVD",
            "id": "CVE-2024-2900"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20548"
          },
          {
            "date": "2025-01-23T02:49:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017294"
          },
          {
            "date": "2025-01-22T17:51:57.717000",
            "db": "NVD",
            "id": "CVE-2024-2900"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017294"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-1047

    Vulnerability from variot - Updated: 2025-09-08 23:24

    A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-1047",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20552"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017249"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2901"
          }
        ]
      },
      "cve": "CVE-2024-2901",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-2901",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017249",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-20552",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-2901",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017249",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-2901",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-2901",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017249",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-20552",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20552"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017249"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2901"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2901"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-2901"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017249"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20552"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-2901",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "257944",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017249",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20552",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20552"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017249"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2901"
          }
        ]
      },
      "id": "VAR-202403-1047",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20552"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20552"
          }
        ]
      },
      "last_update_date": "2025-09-08T23:24:21.418000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC7 setSchedWifi method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/729286"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20552"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017249"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2901"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?id.257944"
          },
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?submit.300367"
          },
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac7/v1/setschedwifi.md"
          },
          {
            "trust": 1.6,
            "url": "https://vuldb.com/?ctiid.257944"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2901"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2024-2901/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20552"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017249"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2901"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20552"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017249"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2901"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20552"
          },
          {
            "date": "2025-01-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017249"
          },
          {
            "date": "2024-03-26T20:15:10.933000",
            "db": "NVD",
            "id": "CVE-2024-2901"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20552"
          },
          {
            "date": "2025-01-23T02:35:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017249"
          },
          {
            "date": "2025-01-22T17:51:47.007000",
            "db": "NVD",
            "id": "CVE-2024-2901"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017249"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-1068

    Vulnerability from variot - Updated: 2025-09-08 23:24

    A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-1068",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20550"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017244"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2902"
          }
        ]
      },
      "cve": "CVE-2024-2902",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-2902",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017244",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-20550",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-2902",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017244",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-2902",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-2902",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017244",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-20550",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20550"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017244"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2902"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2902"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-2902"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017244"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20550"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-2902",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "257945",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017244",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20550",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20550"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017244"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2902"
          }
        ]
      },
      "id": "VAR-202403-1068",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20550"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20550"
          }
        ]
      },
      "last_update_date": "2025-09-08T23:24:21.396000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC7 fromSetWifiGusetBasic method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/729276"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20550"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017244"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2902"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?id.257945"
          },
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?submit.300449"
          },
          {
            "trust": 1.6,
            "url": "https://vuldb.com/?ctiid.257945"
          },
          {
            "trust": 1.6,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac7/v1/fromsetwifigusetbasic.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2902"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2024-2902/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20550"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017244"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2902"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20550"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017244"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2902"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20550"
          },
          {
            "date": "2025-01-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017244"
          },
          {
            "date": "2024-03-26T20:15:11.203000",
            "db": "NVD",
            "id": "CVE-2024-2902"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20550"
          },
          {
            "date": "2025-01-23T02:24:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017244"
          },
          {
            "date": "2025-01-22T17:51:36.857000",
            "db": "NVD",
            "id": "CVE-2024-2902"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017244"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-0956

    Vulnerability from variot - Updated: 2025-09-08 23:15

    A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0956",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20554"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017250"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2899"
          }
        ]
      },
      "cve": "CVE-2024-2899",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-2899",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017250",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-20554",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-2899",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017250",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-2899",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-2899",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017250",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-20554",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20554"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017250"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2899"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2899"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-2899"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017250"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20554"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-2899",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "257942",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017250",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20554",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20554"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017250"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2899"
          }
        ]
      },
      "id": "VAR-202403-0956",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20554"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20554"
          }
        ]
      },
      "last_update_date": "2025-09-08T23:15:53.496000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC7 fromSetWirelessRepeat method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/729296"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20554"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017250"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2899"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?id.257942"
          },
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?submit.300362"
          },
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac7/v1/fromsetwirelessrepeat.md"
          },
          {
            "trust": 1.6,
            "url": "https://vuldb.com/?ctiid.257942"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2899"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2024-2899/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20554"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017250"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2899"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20554"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017250"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2899"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20554"
          },
          {
            "date": "2025-01-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017250"
          },
          {
            "date": "2024-03-26T19:15:49.410000",
            "db": "NVD",
            "id": "CVE-2024-2899"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20554"
          },
          {
            "date": "2025-01-23T02:35:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017250"
          },
          {
            "date": "2025-01-22T17:52:49.950000",
            "db": "NVD",
            "id": "CVE-2024-2899"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017250"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-0640

    Vulnerability from variot - Updated: 2025-09-08 23:14

    Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter. Shenzhen Tenda Technology Co.,Ltd. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. An attacker could exploit this vulnerability to execute arbitrary commands

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0640",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20547"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020542"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32281"
          }
        ]
      },
      "cve": "CVE-2024-32281",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-20547",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-32281",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020542",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-32281",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020542",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-20547",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20547"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020542"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32281"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter. Shenzhen Tenda Technology Co.,Ltd. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. An attacker could exploit this vulnerability to execute arbitrary commands",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-32281"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020542"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20547"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-32281",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020542",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20547",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20547"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020542"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32281"
          }
        ]
      },
      "id": "VAR-202404-0640",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20547"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20547"
          }
        ]
      },
      "last_update_date": "2025-09-08T23:14:53.949000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC7 command injection vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/729261"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20547"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020542"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32281"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.6,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac7/v1/formexecommand.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-32281"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20547"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020542"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32281"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20547"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020542"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32281"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20547"
          },
          {
            "date": "2025-03-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020542"
          },
          {
            "date": "2024-04-17T13:15:08.247000",
            "db": "NVD",
            "id": "CVE-2024-32281"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20547"
          },
          {
            "date": "2025-03-18T03:14:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020542"
          },
          {
            "date": "2025-03-17T14:35:04.940000",
            "db": "NVD",
            "id": "CVE-2024-32281"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Command injection vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020542"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-0943

    Vulnerability from variot - Updated: 2025-09-08 23:14

    A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0943",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20549"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017265"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2898"
          }
        ]
      },
      "cve": "CVE-2024-2898",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-2898",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017265",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-20549",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-2898",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017265",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-2898",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-2898",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017265",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-20549",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20549"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017265"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2898"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2898"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-2898"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017265"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20549"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-2898",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "257941",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017265",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20549",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20549"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017265"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2898"
          }
        ]
      },
      "id": "VAR-202403-0943",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20549"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20549"
          }
        ]
      },
      "last_update_date": "2025-09-08T23:14:25.047000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC7 fromSetRouteStatic method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/729271"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20549"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017265"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2898"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?id.257941"
          },
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?submit.300361"
          },
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac7/v1/fromsetroutestatic.md"
          },
          {
            "trust": 1.6,
            "url": "https://vuldb.com/?ctiid.257941"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2898"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2024-2898/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20549"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017265"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2898"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20549"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017265"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2898"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20549"
          },
          {
            "date": "2025-01-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017265"
          },
          {
            "date": "2024-03-26T19:15:49.130000",
            "db": "NVD",
            "id": "CVE-2024-2898"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20549"
          },
          {
            "date": "2025-01-23T02:42:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017265"
          },
          {
            "date": "2025-01-22T17:52:16.723000",
            "db": "NVD",
            "id": "CVE-2024-2898"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017265"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-1048

    Vulnerability from variot - Updated: 2025-09-08 23:14

    A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-1048",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20551"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017272"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2892"
          }
        ]
      },
      "cve": "CVE-2024-2892",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-2892",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017272",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-20551",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-2892",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017272",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-2892",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-2892",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017272",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-20551",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20551"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017272"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2892"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2892"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. Detailed vulnerability details are currently unavailable",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-2892"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017272"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20551"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-2892",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "257935",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017272",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20551",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20551"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017272"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2892"
          }
        ]
      },
      "id": "VAR-202403-1048",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20551"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20551"
          }
        ]
      },
      "last_update_date": "2025-09-08T23:14:25.020000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC7 formSetCfm method buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/729281"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20551"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017272"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2892"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?id.257935"
          },
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?submit.300355"
          },
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac7/v1/formsetcfm.md"
          },
          {
            "trust": 1.6,
            "url": "https://vuldb.com/?ctiid.257935"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2892"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2024-2892/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20551"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017272"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2892"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20551"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017272"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2892"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20551"
          },
          {
            "date": "2025-01-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017272"
          },
          {
            "date": "2024-03-26T16:15:13.853000",
            "db": "NVD",
            "id": "CVE-2024-2892"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20551"
          },
          {
            "date": "2025-01-23T02:43:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017272"
          },
          {
            "date": "2025-01-22T17:58:23.927000",
            "db": "NVD",
            "id": "CVE-2024-2892"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Out-of-bounds write vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017272"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202403-0944

    Vulnerability from variot - Updated: 2025-09-08 23:03

    A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps.

    The Tenda AC7 suffers from a command injection vulnerability stemming from a buffer overflow in the mac parameter of the formWriteFacMac method. Detailed vulnerability details are currently unavailable

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0944",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20553"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017271"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2897"
          }
        ]
      },
      "cve": "CVE-2024-2897",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CVE-2024-2897",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Partial",
                "baseScore": 6.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017271",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-20553",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "LOW",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-2897",
                "impactScore": 3.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-2897",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-017271",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2024-2897",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-2897",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-017271",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-20553",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20553"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017271"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2897"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2897"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of AC7 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. It utilizes the 802.11ac standard, supports dual-band concurrent transmission, and offers wireless speeds up to 1167Mbps. \n\nThe Tenda AC7 suffers from a command injection vulnerability stemming from a buffer overflow in the mac parameter of the formWriteFacMac method. Detailed vulnerability details are currently unavailable",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-2897"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017271"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20553"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-2897",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "257940",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017271",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-20553",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20553"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017271"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2897"
          }
        ]
      },
      "id": "VAR-202403-0944",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20553"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20553"
          }
        ]
      },
      "last_update_date": "2025-09-08T23:03:45.431000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC7 command injection vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/729291"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20553"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "OS Command injection (CWE-78) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017271"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2897"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?id.257940"
          },
          {
            "trust": 2.4,
            "url": "https://vuldb.com/?submit.300360"
          },
          {
            "trust": 2.4,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac7/v1/formwritefacmac.md"
          },
          {
            "trust": 1.6,
            "url": "https://vuldb.com/?ctiid.257940"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2897"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2024-2897/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20553"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017271"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2897"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-20553"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017271"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-2897"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20553"
          },
          {
            "date": "2025-01-23T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017271"
          },
          {
            "date": "2024-03-26T19:15:48.857000",
            "db": "NVD",
            "id": "CVE-2024-2897"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-05T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-20553"
          },
          {
            "date": "2025-01-23T02:43:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-017271"
          },
          {
            "date": "2025-01-22T17:53:14.800000",
            "db": "NVD",
            "id": "CVE-2024-2897"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-017271"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202507-2440

    Vulnerability from variot - Updated: 2025-08-06 23:09

    A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. of AC7 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the function formSetMacFilterCfg in the file /goform/setMacFilterCfg failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202507-2440",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16842"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-010654"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-8017"
          }
        ]
      },
      "cve": "CVE-2025-8017",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-8017",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-010654",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-16842",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-8017",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-010654",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-8017",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-010654",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-16842",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16842"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-010654"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-8017"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. of AC7 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the function formSetMacFilterCfg in the file /goform/setMacFilterCfg failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-8017"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-010654"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-16842"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-8017",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "317220",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-010654",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-16842",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16842"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-010654"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-8017"
          }
        ]
      },
      "id": "VAR-202507-2440",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16842"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16842"
          }
        ]
      },
      "last_update_date": "2025-08-06T23:09:33.189000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-010654"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-8017"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/thir0th/thir0th-cve/blob/main/tenda_ac7%20v1.0_v15.03.06.44%20has%20a%20stack%20overflow%20vulnerability%20in%20parse_macfilter_rule.md"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.317220"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.619364"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-8017"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.317220"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16842"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-010654"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-8017"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16842"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-010654"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-8017"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-07-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-16842"
          },
          {
            "date": "2025-08-05T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-010654"
          },
          {
            "date": "2025-07-22T14:15:48.403000",
            "db": "NVD",
            "id": "CVE-2025-8017"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-07-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-16842"
          },
          {
            "date": "2025-08-05T07:04:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-010654"
          },
          {
            "date": "2025-08-01T20:02:50.773000",
            "db": "NVD",
            "id": "CVE-2025-8017"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Buffer error vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-010654"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0050

    Vulnerability from variot - Updated: 2025-07-22 23:45

    A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the TendaTelnet function in the /goform/telnet file failing to properly filter special characters and commands in the constructed command. Attackers can exploit this vulnerability to cause arbitrary command execution

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0050",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-05230"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-009338"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-1819"
          }
        ]
      },
      "cve": "CVE-2025-1819",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-1819",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Partial",
                "baseScore": 6.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-009338",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-05230",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "LOW",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-1819",
                "impactScore": 3.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-1819",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-009338",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-1819",
                "trust": 1.0,
                "value": "Medium"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-1819",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-009338",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-05230",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-05230"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-009338"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-1819"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-1819"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the TendaTelnet function in the /goform/telnet file failing to properly filter special characters and commands in the constructed command. Attackers can exploit this vulnerability to cause arbitrary command execution",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-1819"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-009338"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-05230"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-1819",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "298092",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-009338",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-05230",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-05230"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-009338"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-1819"
          }
        ]
      },
      "id": "VAR-202503-0050",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-05230"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-05230"
          }
        ]
      },
      "last_update_date": "2025-07-22T23:45:41.176000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": "OS Command injection (CWE-78) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-009338"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-1819"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.298092"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.504429"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-1819"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.298092"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/raining-101/iot_cve/blob/main/tenda%20a7%20v15.03.06.44%20command%20injection.md"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-05230"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-009338"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-1819"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-05230"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-009338"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-1819"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-03-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-05230"
          },
          {
            "date": "2025-07-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-009338"
          },
          {
            "date": "2025-03-02T17:15:11.483000",
            "db": "NVD",
            "id": "CVE-2025-1819"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-03-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-05230"
          },
          {
            "date": "2025-07-18T08:39:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-009338"
          },
          {
            "date": "2025-07-16T14:13:01.587000",
            "db": "NVD",
            "id": "CVE-2025-1819"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Command injection vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-009338"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202404-0443

    Vulnerability from variot - Updated: 2025-07-20 23:05

    Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds read vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC7 is a dual-band router launched by Tenda Technology, focusing on signal coverage and high-speed transmission for large households. The vulnerability is caused by the PPW parameter of the fromWizardHandle method failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0443",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16336"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020568"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32301"
          }
        ]
      },
      "cve": "CVE-2024-32301",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-16336",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-32301",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-020568",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-32301",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-020568",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-16336",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16336"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020568"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32301"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function. Shenzhen Tenda Technology Co.,Ltd. of AC7 An out-of-bounds read vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC7 is a dual-band router launched by Tenda Technology, focusing on signal coverage and high-speed transmission for large households. The vulnerability is caused by the PPW parameter of the fromWizardHandle method failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-32301"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020568"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-16336"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-32301",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020568",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-16336",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16336"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020568"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32301"
          }
        ]
      },
      "id": "VAR-202404-0443",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16336"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16336"
          }
        ]
      },
      "last_update_date": "2025-07-20T23:05:30.715000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Tenda AC7 Buffer Overflow Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/710431"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16336"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-125",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds read (CWE-125) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020568"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32301"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.6,
            "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac7/v1/fromwizardhandle.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-32301"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16336"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020568"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32301"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-16336"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020568"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-32301"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-07-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-16336"
          },
          {
            "date": "2025-03-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020568"
          },
          {
            "date": "2024-04-17T13:15:08.293000",
            "db": "NVD",
            "id": "CVE-2024-32301"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-07-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-16336"
          },
          {
            "date": "2025-03-19T01:19:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020568"
          },
          {
            "date": "2025-03-17T14:37:20.667000",
            "db": "NVD",
            "id": "CVE-2024-32301"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Out-of-bounds read vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020568"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202506-0454

    Vulnerability from variot - Updated: 2025-06-19 23:41

    A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC7 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC7 is a high-performance dual-band wireless router designed for large households, with strong signal coverage and stable network performance. No detailed vulnerability details are currently provided

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202506-0454",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12742"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006553"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5862"
          }
        ]
      },
      "cve": "CVE-2025-5862",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-5862",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006553",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-12742",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-5862",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-5862",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006553",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-5862",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-5862",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006553",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-12742",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12742"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006553"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5862"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5862"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC7 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC7 is a high-performance dual-band wireless router designed for large households, with strong signal coverage and stable network performance. No detailed vulnerability details are currently provided",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-5862"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006553"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-12742"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-5862",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "311621",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006553",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-12742",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12742"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006553"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5862"
          }
        ]
      },
      "id": "VAR-202506-0454",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12742"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12742"
          }
        ]
      },
      "last_update_date": "2025-06-19T23:41:26.471000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Classic buffer overflow (CWE-120) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006553"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5862"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://lavender-bicycle-a5a.notion.site/tenda-ac7-formsetpptpuserlist-20a53a41781f806ca124cbdf99bff931?source=copy_link"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.311621"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.591980"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.8,
            "url": "https://lavender-bicycle-a5a.notion.site/tenda-ac7-formsetpptpuserlist-20a53a41781f806ca124cbdf99bff931"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-5862"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.311621"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12742"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006553"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5862"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12742"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006553"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5862"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-12742"
          },
          {
            "date": "2025-06-10T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006553"
          },
          {
            "date": "2025-06-09T05:15:21.887000",
            "db": "NVD",
            "id": "CVE-2025-5862"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-12742"
          },
          {
            "date": "2025-06-10T06:22:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006553"
          },
          {
            "date": "2025-06-09T19:02:54.097000",
            "db": "NVD",
            "id": "CVE-2025-5862"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006553"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202506-0478

    Vulnerability from variot - Updated: 2025-06-19 23:34

    A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC7 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC7 has a buffer overflow vulnerability, which is caused by the parameter lanMask in the file /goform/AdvSetLanip failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202506-0478",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12739"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006526"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5861"
          }
        ]
      },
      "cve": "CVE-2025-5861",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-5861",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006526",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-12739",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-5861",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-5861",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-006526",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-5861",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-5861",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-006526",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-12739",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12739"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006526"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5861"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5861"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC7 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC7 has a buffer overflow vulnerability, which is caused by the parameter lanMask in the file /goform/AdvSetLanip failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-5861"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006526"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-12739"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-5861",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "311620",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006526",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-12739",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12739"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006526"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5861"
          }
        ]
      },
      "id": "VAR-202506-0478",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12739"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12739"
          }
        ]
      },
      "last_update_date": "2025-06-19T23:34:53.693000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Classic buffer overflow (CWE-120) [NVD evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006526"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5861"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://lavender-bicycle-a5a.notion.site/tenda-ac7-fromadvsetlanip-20a53a41781f80038f4fc4b9d927eb9a"
          },
          {
            "trust": 1.8,
            "url": "https://lavender-bicycle-a5a.notion.site/tenda-ac7-fromadvsetlanip-20a53a41781f80038f4fc4b9d927eb9a?source=copy_link"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.311620"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.591960"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.311620"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-5861"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12739"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006526"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5861"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-12739"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006526"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-5861"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-12739"
          },
          {
            "date": "2025-06-10T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006526"
          },
          {
            "date": "2025-06-09T05:15:20.297000",
            "db": "NVD",
            "id": "CVE-2025-5861"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-06-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-12739"
          },
          {
            "date": "2025-06-10T01:54:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-006526"
          },
          {
            "date": "2025-06-09T19:03:01.067000",
            "db": "NVD",
            "id": "CVE-2025-5861"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-006526"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-1764

    Vulnerability from variot - Updated: 2025-05-29 23:39

    A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. of AC7 The firmware contains a buffer error vulnerability, a stack-based buffer overflow vulnerability, and an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC7 has a buffer overflow vulnerability, which is caused by the parameter reboot_time in the file /goform/SetRebootTimer failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-1764",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10593"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005615"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4810"
          }
        ]
      },
      "cve": "CVE-2025-4810",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-4810",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-005615",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-10593",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-4810",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-005615",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-4810",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-005615",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-10593",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10593"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005615"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4810"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. of AC7 The firmware contains a buffer error vulnerability, a stack-based buffer overflow vulnerability, and an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC7 has a buffer overflow vulnerability, which is caused by the parameter reboot_time in the file /goform/SetRebootTimer failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-4810"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005615"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10593"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-4810",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "309265",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005615",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10593",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10593"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005615"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4810"
          }
        ]
      },
      "id": "VAR-202505-1764",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10593"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10593"
          }
        ]
      },
      "last_update_date": "2025-05-29T23:39:39.265000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005615"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4810"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://lavender-bicycle-a5a.notion.site/tenda-ac7-formsetreboottimer-1ed53a41781f80f78851c1c9dfc4f216?pvs=4"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.309265"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.573643"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.309265"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-4810"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10593"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005615"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4810"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10593"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005615"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4810"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10593"
          },
          {
            "date": "2025-05-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005615"
          },
          {
            "date": "2025-05-16T21:15:35.583000",
            "db": "NVD",
            "id": "CVE-2025-4810"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-26T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10593"
          },
          {
            "date": "2025-05-26T00:39:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005615"
          },
          {
            "date": "2025-05-24T01:12:25.480000",
            "db": "NVD",
            "id": "CVE-2025-4810"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Buffer error vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005615"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-1823

    Vulnerability from variot - Updated: 2025-05-29 23:38

    A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. of AC7 The firmware contains a buffer error vulnerability, a stack-based buffer overflow vulnerability, and an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC7 has a buffer overflow vulnerability, which is caused by the failure of the parameter deviceList in the file /goform/setMacFilterCfg to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-1823",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10592"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005664"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4809"
          }
        ]
      },
      "cve": "CVE-2025-4809",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-4809",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-005664",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-10592",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-4809",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-005664",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-4809",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-005664",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-10592",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10592"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005664"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4809"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. of AC7 The firmware contains a buffer error vulnerability, a stack-based buffer overflow vulnerability, and an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC7 has a buffer overflow vulnerability, which is caused by the failure of the parameter deviceList in the file /goform/setMacFilterCfg to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-4809"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005664"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10592"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-4809",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "309264",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005664",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10592",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10592"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005664"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4809"
          }
        ]
      },
      "id": "VAR-202505-1823",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10592"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10592"
          }
        ]
      },
      "last_update_date": "2025-05-29T23:38:41.460000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005664"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4809"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://lavender-bicycle-a5a.notion.site/tenda-ac7-fromsafesetmacfilter-1ed53a41781f80cbbf13c8d4cc405ed1?pvs=4"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.309264"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.573642"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.309264"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-4809"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10592"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005664"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4809"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10592"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005664"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-4809"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10592"
          },
          {
            "date": "2025-05-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005664"
          },
          {
            "date": "2025-05-16T20:15:22.773000",
            "db": "NVD",
            "id": "CVE-2025-4809"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-26T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10592"
          },
          {
            "date": "2025-05-26T06:46:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005664"
          },
          {
            "date": "2025-05-24T01:11:08.893000",
            "db": "NVD",
            "id": "CVE-2025-4809"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Buffer error vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005664"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202504-0826

    Vulnerability from variot - Updated: 2025-05-29 23:37

    A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. of AC7 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202504-0826",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08782"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005759"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3346"
          }
        ]
      },
      "cve": "CVE-2025-3346",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "cna@vuldb.com",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2025-3346",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "OTHER",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-005759",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2025-08782",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cna@vuldb.com",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-3346",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-005759",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "cna@vuldb.com",
                "id": "CVE-2025-3346",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-005759",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-08782",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08782"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005759"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3346"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. of AC7 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-3346"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005759"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08782"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-3346",
            "trust": 3.2
          },
          {
            "db": "VULDB",
            "id": "303560",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005759",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-08782",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08782"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005759"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3346"
          }
        ]
      },
      "id": "VAR-202504-0826",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08782"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08782"
          }
        ]
      },
      "last_update_date": "2025-05-29T23:37:03.682000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          },
          {
            "problemtype": " Classic buffer overflow (CWE-120) [NVD evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005759"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3346"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?id.303560"
          },
          {
            "trust": 1.8,
            "url": "https://vuldb.com/?submit.551927"
          },
          {
            "trust": 1.8,
            "url": "https://www.tenda.com.cn/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-3346"
          },
          {
            "trust": 1.0,
            "url": "https://vuldb.com/?ctiid.303560"
          },
          {
            "trust": 1.0,
            "url": "https://github.com/ch13hh/tmp_store_cc/blob/main/ac7formsetpptpserver/formsetpptpserver.md"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08782"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005759"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3346"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-08782"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005759"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-3346"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08782"
          },
          {
            "date": "2025-05-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005759"
          },
          {
            "date": "2025-04-07T10:15:15.153000",
            "db": "NVD",
            "id": "CVE-2025-3346"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-29T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-08782"
          },
          {
            "date": "2025-05-28T05:41:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-005759"
          },
          {
            "date": "2025-05-27T14:22:29.283000",
            "db": "NVD",
            "id": "CVE-2025-3346"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Buffer error vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-005759"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202410-2677

    Vulnerability from variot - Updated: 2025-05-28 23:17

    Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. Shenzhen Tenda Technology Co.,Ltd. of AC7 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC7 has a command injection vulnerability, which is caused by ate_iwpriv_set failing to properly filter special characters and commands in constructing commands

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202410-2677",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10600"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020546"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48826"
          }
        ]
      },
      "cve": "CVE-2024-48826",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.7,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.1,
                "id": "CNVD-2025-10600",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-48826",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 8.0,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.1,
                "id": "CVE-2024-48826",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2024-48826",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-48826",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-48826",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2024-48826",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-10600",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10600"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020546"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48826"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48826"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. Shenzhen Tenda Technology Co.,Ltd. of AC7 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC7 has a command injection vulnerability, which is caused by ate_iwpriv_set failing to properly filter special characters and commands in constructing commands",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-48826"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020546"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10600"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-48826",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020546",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10600",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10600"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020546"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48826"
          }
        ]
      },
      "id": "VAR-202410-2677",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10600"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10600"
          }
        ]
      },
      "last_update_date": "2025-05-28T23:17:33.535000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": "OS Command injection (CWE-78) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020546"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48826"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/ixout/iotvuls/blob/main/tenda/ac7_006/report.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-48826"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10600"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020546"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48826"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10600"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020546"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48826"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-26T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10600"
          },
          {
            "date": "2025-03-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020546"
          },
          {
            "date": "2024-10-28T20:15:06.237000",
            "db": "NVD",
            "id": "CVE-2024-48826"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-26T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10600"
          },
          {
            "date": "2025-03-18T03:16:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020546"
          },
          {
            "date": "2025-03-17T14:41:08.920000",
            "db": "NVD",
            "id": "CVE-2024-48826"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020546"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202410-3361

    Vulnerability from variot - Updated: 2025-05-28 23:11

    Tenda AC7 v.15.03.06.44 ate_ifconfig_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. Shenzhen Tenda Technology Co.,Ltd. of AC7 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

    Tenda AC7 has a command injection vulnerability, which is caused by ate_ifconfig_set failing to properly filter special characters and commands in constructing commands

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202410-3361",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10599"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020574"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48825"
          }
        ]
      },
      "cve": "CVE-2024-48825",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.7,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.1,
                "id": "CNVD-2025-10599",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2024-48825",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 8.0,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.1,
                "id": "CVE-2024-48825",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2024-48825",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2024-48825",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-48825",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2024-48825",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-10599",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10599"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020574"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48825"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48825"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC7 v.15.03.06.44 ate_ifconfig_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. Shenzhen Tenda Technology Co.,Ltd. of AC7 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC7 has a command injection vulnerability, which is caused by ate_ifconfig_set failing to properly filter special characters and commands in constructing commands",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-48825"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020574"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10599"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-48825",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020574",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-10599",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10599"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020574"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48825"
          }
        ]
      },
      "id": "VAR-202410-3361",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10599"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10599"
          }
        ]
      },
      "last_update_date": "2025-05-28T23:11:04.163000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": "OS Command injection (CWE-78) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020574"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48825"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://github.com/ixout/iotvuls/blob/main/tenda/ac7_005/report.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-48825"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10599"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020574"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48825"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-10599"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020574"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-48825"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-26T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10599"
          },
          {
            "date": "2025-03-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020574"
          },
          {
            "date": "2024-10-28T20:15:06.173000",
            "db": "NVD",
            "id": "CVE-2024-48825"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-26T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-10599"
          },
          {
            "date": "2025-03-19T01:27:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-020574"
          },
          {
            "date": "2025-03-17T14:40:19.617000",
            "db": "NVD",
            "id": "CVE-2024-48825"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-020574"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0684

    Vulnerability from variot - Updated: 2025-04-20 23:30

    Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE. Shenzhen Tenda Technology Co.,Ltd. of AC7 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to execute arbitrary code on the system

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0684",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07593"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002841"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29137"
          }
        ]
      },
      "cve": "CVE-2025-29137",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-07593",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29137",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-002841",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29137",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-002841",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-07593",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07593"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002841"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29137"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE. Shenzhen Tenda Technology Co.,Ltd. of AC7 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Attackers can exploit this vulnerability to execute arbitrary code on the system",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29137"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002841"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-07593"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29137",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002841",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-07593",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07593"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002841"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29137"
          }
        ]
      },
      "id": "VAR-202503-0684",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07593"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07593"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:30:35.151000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002841"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29137"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://github.com/raining-101/iot_cve/blob/main/tenda-ac7form_fast_setting_wifi_set%20timezone.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29137"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07593"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002841"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29137"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07593"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002841"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29137"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-07593"
          },
          {
            "date": "2025-04-02T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002841"
          },
          {
            "date": "2025-03-19T16:15:31.677000",
            "db": "NVD",
            "id": "CVE-2025-29137"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-07593"
          },
          {
            "date": "2025-04-02T08:44:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002841"
          },
          {
            "date": "2025-04-01T20:37:02.110000",
            "db": "NVD",
            "id": "CVE-2025-29137"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Classic buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002841"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-2861

    Vulnerability from variot - Updated: 2025-04-20 23:29

    A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function. Shenzhen Tenda Technology Co.,Ltd. of AC7 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the formWifiBasicSet function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-2861",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "tenda",
            "version": "15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": "ac7  firmware  15.03.06.44"
          },
          {
            "model": "ac7",
            "scope": null,
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "tenda",
            "version": null
          },
          {
            "model": "ac7",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v15.03.06.44"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07535"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002871"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29135"
          }
        ]
      },
      "cve": "CVE-2025-29135",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-07535",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-29135",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-002871",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2025-29135",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-002871",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-07535",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07535"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002871"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29135"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function. Shenzhen Tenda Technology Co.,Ltd. of AC7 A stack-based buffer overflow vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the formWifiBasicSet function failing to properly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-29135"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002871"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-07535"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-29135",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002871",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-07535",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07535"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002871"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29135"
          }
        ]
      },
      "id": "VAR-202503-2861",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07535"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07535"
          }
        ]
      },
      "last_update_date": "2025-04-20T23:29:16.961000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002871"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29135"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://gist.github.com/raining-101/1651dd3901efdbb38d94a156a54bbc62"
          },
          {
            "trust": 1.8,
            "url": "https://github.com/raining-101/iot_cve/blob/main/a7_formwifibasic_setsecurity_stackoverflow.md"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-29135"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07535"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002871"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29135"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-07535"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002871"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-29135"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-11T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-07535"
          },
          {
            "date": "2025-04-03T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002871"
          },
          {
            "date": "2025-03-24T21:15:17.787000",
            "db": "NVD",
            "id": "CVE-2025-29135"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-04-18T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-07535"
          },
          {
            "date": "2025-04-03T01:30:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-002871"
          },
          {
            "date": "2025-04-01T19:58:46.270000",
            "db": "NVD",
            "id": "CVE-2025-29135"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 Stack-based buffer overflow vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-002871"
          }
        ],
        "trust": 0.8
      }
    }