Search criteria

40 vulnerabilities found for ac21 by tenda

CVE-2026-1638 (GCVE-0-2026-1638)

Vulnerability from nvd – Published: 2026-01-29 23:32 – Updated: 2026-01-30 18:25
VLAI?
Title
Tenda AC21 mDMZSetCfg command injection
Summary
A security flaw has been discovered in Tenda AC21 1.1.1.1/1.dmzip/16.03.08.16. The impacted element is the function mDMZSetCfg of the file /goform/mDMZSetCfg. The manipulation of the argument dmzIp results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks.
CWE
Assigner
References
https://vuldb.com/?id.343417 vdb-entrytechnical-description
https://vuldb.com/?ctiid.343417 signaturepermissions-required
https://vuldb.com/?submit.740871 third-party-advisory
https://github.com/LX-LX88/cve/issues/26 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 1.1.1.1
Affected: 1.dmzip
Affected: 16.03.08.16
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-1638",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T18:25:39.642410Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-30T18:25:59.761Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.1.1.1"
            },
            {
              "status": "affected",
              "version": "1.dmzip"
            },
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw has been discovered in Tenda AC21 1.1.1.1/1.dmzip/16.03.08.16. The impacted element is the function mDMZSetCfg of the file /goform/mDMZSetCfg. The manipulation of the argument dmzIp results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-29T23:32:11.350Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-343417 | Tenda AC21 mDMZSetCfg command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.343417"
        },
        {
          "name": "VDB-343417 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.343417"
        },
        {
          "name": "Submit #740871 | Tenda AC21 V16.03.08.16 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.740871"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/26"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-01-29T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-01-29T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-01-29T18:01:32.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 mDMZSetCfg command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-1638",
    "datePublished": "2026-01-29T23:32:11.350Z",
    "dateReserved": "2026-01-29T16:56:25.779Z",
    "dateUpdated": "2026-01-30T18:25:59.761Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-1637 (GCVE-0-2026-1637)

Vulnerability from nvd – Published: 2026-01-29 22:32 – Updated: 2026-02-02 16:33
VLAI?
Title
Tenda AC21 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow
Summary
A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CWE
Assigner
References
https://vuldb.com/?id.343416 vdb-entrytechnical-description
https://vuldb.com/?ctiid.343416 signaturepermissions-required
https://vuldb.com/?submit.740865 third-party-advisory
https://github.com/LX-LX88/cve/issues/25 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-1637",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T14:36:34.085802Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-02T16:33:53.523Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/LX-LX88/cve/issues/25"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-29T22:32:07.685Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-343416 | Tenda AC21 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.343416"
        },
        {
          "name": "VDB-343416 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.343416"
        },
        {
          "name": "Submit #740865 | Tenda AC21 V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.740865"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/25"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-01-29T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-01-29T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-01-29T18:01:30.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-1637",
    "datePublished": "2026-01-29T22:32:07.685Z",
    "dateReserved": "2026-01-29T16:56:17.581Z",
    "dateUpdated": "2026-02-02T16:33:53.523Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13446 (GCVE-0-2025-13446)

Vulnerability from nvd – Published: 2025-11-20 02:32 – Updated: 2025-11-20 14:52
VLAI?
Title
Tenda AC21 SetSysTimeCfg stack-based overflow
Summary
A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
jiahui288 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13446",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T14:16:02.059248Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T14:52:07.354Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN8.md"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN9.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jiahui288 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T02:32:07.969Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-333018 | Tenda AC21 SetSysTimeCfg stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.333018"
        },
        {
          "name": "VDB-333018 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.333018"
        },
        {
          "name": "Submit #694425 | Tenda AC21 V16.03.08.16  Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694425"
        },
        {
          "name": "Submit #694430 | Tenda AC21 V16.03.08.16  Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694430"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN8.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN9.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-19T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-19T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-19T20:19:45.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetSysTimeCfg stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-13446",
    "datePublished": "2025-11-20T02:32:07.969Z",
    "dateReserved": "2025-11-19T19:14:38.513Z",
    "dateUpdated": "2025-11-20T14:52:07.354Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13445 (GCVE-0-2025-13445)

Vulnerability from nvd – Published: 2025-11-20 02:02 – Updated: 2025-11-20 14:52
VLAI?
Title
Tenda AC21 SetIpMacBind stack-based overflow
Summary
A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
jiahui288 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13445",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T14:17:02.610671Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T14:52:14.900Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN7.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jiahui288 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T02:02:09.585Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-333017 | Tenda AC21 SetIpMacBind stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.333017"
        },
        {
          "name": "VDB-333017 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.333017"
        },
        {
          "name": "Submit #694066 | Tenda AC21 V16.03.08.16  Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694066"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN7.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-19T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-19T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-19T20:19:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetIpMacBind stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-13445",
    "datePublished": "2025-11-20T02:02:09.585Z",
    "dateReserved": "2025-11-19T19:14:36.023Z",
    "dateUpdated": "2025-11-20T14:52:14.900Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12611 (GCVE-0-2025-12611)

Vulnerability from nvd – Published: 2025-11-03 02:02 – Updated: 2025-11-03 14:26
VLAI?
Title
Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow
Summary
A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CWE
Assigner
References
https://vuldb.com/?id.330906 vdb-entrytechnical-description
https://vuldb.com/?ctiid.330906 signaturepermissions-required
https://vuldb.com/?submit.678491 third-party-advisory
https://github.com/LX-LX88/cve/issues/10 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12611",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T14:16:45.645981Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T14:26:36.736Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC21 16.03.08.16 wurde eine Schwachstelle gefunden. Es geht dabei um die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Mit der Manipulation des Arguments startIp mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-03T02:02:09.734Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-330906 | Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.330906"
        },
        {
          "name": "VDB-330906 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.330906"
        },
        {
          "name": "Submit #678491 | Tenda AC21 V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.678491"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/10"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-02T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-02T07:33:49.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-12611",
    "datePublished": "2025-11-03T02:02:09.734Z",
    "dateReserved": "2025-11-02T06:28:46.133Z",
    "dateUpdated": "2025-11-03T14:26:36.736Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-11091 (GCVE-0-2025-11091)

Vulnerability from nvd – Published: 2025-09-28 01:32 – Updated: 2025-09-29 14:48
VLAI?
Title
Tenda AC21 SetStaticRouteCfg sscanf buffer overflow
Summary
A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited.
CWE
Assigner
References
https://vuldb.com/?id.326173 vdb-entrytechnical-description
https://vuldb.com/?ctiid.326173 signaturepermissions-required
https://vuldb.com/?submit.661806 third-party-advisory
https://github.com/maximdevere/CVE2/issues/2 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.0
Affected: 16.03.08.1
Affected: 16.03.08.2
Affected: 16.03.08.3
Affected: 16.03.08.4
Affected: 16.03.08.5
Affected: 16.03.08.6
Affected: 16.03.08.7
Affected: 16.03.08.8
Affected: 16.03.08.9
Affected: 16.03.08.10
Affected: 16.03.08.11
Affected: 16.03.08.12
Affected: 16.03.08.13
Affected: 16.03.08.14
Affected: 16.03.08.15
Affected: 16.03.08.16
Create a notification for this product.
Credits
MaximDeVere (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11091",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-29T14:48:52.752774Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-29T14:48:57.508Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/maximdevere/CVE2/issues/2"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.0"
            },
            {
              "status": "affected",
              "version": "16.03.08.1"
            },
            {
              "status": "affected",
              "version": "16.03.08.2"
            },
            {
              "status": "affected",
              "version": "16.03.08.3"
            },
            {
              "status": "affected",
              "version": "16.03.08.4"
            },
            {
              "status": "affected",
              "version": "16.03.08.5"
            },
            {
              "status": "affected",
              "version": "16.03.08.6"
            },
            {
              "status": "affected",
              "version": "16.03.08.7"
            },
            {
              "status": "affected",
              "version": "16.03.08.8"
            },
            {
              "status": "affected",
              "version": "16.03.08.9"
            },
            {
              "status": "affected",
              "version": "16.03.08.10"
            },
            {
              "status": "affected",
              "version": "16.03.08.11"
            },
            {
              "status": "affected",
              "version": "16.03.08.12"
            },
            {
              "status": "affected",
              "version": "16.03.08.13"
            },
            {
              "status": "affected",
              "version": "16.03.08.14"
            },
            {
              "status": "affected",
              "version": "16.03.08.15"
            },
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "MaximDeVere (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC21 up to 16.03.08.16 entdeckt. Dabei geht es um die Funktion sscanf der Datei /goform/SetStaticRouteCfg. Dank Manipulation des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff l\u00e4sst sich \u00fcber das Netzwerk starten. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-28T01:32:10.696Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-326173 | Tenda AC21 SetStaticRouteCfg sscanf buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.326173"
        },
        {
          "name": "VDB-326173 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.326173"
        },
        {
          "name": "Submit #661806 | Shenzhen Tenda Technology Co.,Ltd. AC21 \u003c= V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.661806"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/maximdevere/CVE2/issues/2"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-09-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-09-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-09-27T07:31:48.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetStaticRouteCfg sscanf buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11091",
    "datePublished": "2025-09-28T01:32:10.696Z",
    "dateReserved": "2025-09-27T05:26:44.839Z",
    "dateUpdated": "2025-09-29T14:48:57.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-10838 (GCVE-0-2025-10838)

Vulnerability from nvd – Published: 2025-09-23 04:32 – Updated: 2025-09-23 19:12
VLAI?
Title
Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow
Summary
A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub_45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
QMSSDXN (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10838",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-23T19:12:21.343557Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-23T19:12:30.355Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "QMSSDXN (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub_45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC21 16.03.08.16 gefunden. Es geht dabei um die Funktion sub_45BB10 der Datei /goform/WifiExtraSet. Durch Manipulieren des Arguments wpapsk_crypto mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-23T04:32:07.071Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-325200 | Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.325200"
        },
        {
          "name": "VDB-325200 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.325200"
        },
        {
          "name": "Submit #657126 | Tenda AC21 \u2264V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.657126"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/lin-3-start/lin-cve/blob/main/Tenda%20AC21/Tenda%20AC21%20Buffer%20overflow.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/lin-3-start/lin-cve/blob/main/Tenda%20AC21/Tenda%20AC21%20Buffer%20overflow.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-09-22T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-09-22T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-09-22T07:15:16.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-10838",
    "datePublished": "2025-09-23T04:32:07.071Z",
    "dateReserved": "2025-09-22T05:10:13.621Z",
    "dateUpdated": "2025-09-23T19:12:30.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9605 (GCVE-0-2025-9605)

Vulnerability from nvd – Published: 2025-08-29 02:02 – Updated: 2025-08-29 13:31
VLAI?
Title
Tenda AC21/AC23 GetParentControlInfo stack-based overflow
Summary
A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
lxyilu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9605",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-29T13:31:03.332380Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-29T13:31:06.430Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        },
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "lxyilu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC21 and AC23 16.03.08.16 ist eine Schwachstelle entdeckt worden. Betroffen ist die Funktion GetParentControlInfo der Datei /goform/GetParentControlInfo. Durch das Manipulieren des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Ein Angriff ist aus der Distanz m\u00f6glich. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-29T02:02:08.778Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-321783 | Tenda AC21/AC23 GetParentControlInfo stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.321783"
        },
        {
          "name": "VDB-321783 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.321783"
        },
        {
          "name": "Submit #636545 | Tenda Wi-Fi 5 Router AC21 AC21V1.0re_V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636545"
        },
        {
          "name": "Submit #636548 | Tenda Wi-Fi 5 Router AC23 AC23V1.0re_V16.03.07.52 Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636548"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-08-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-08-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-08-28T17:27:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21/AC23 GetParentControlInfo stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-9605",
    "datePublished": "2025-08-29T02:02:08.778Z",
    "dateReserved": "2025-08-28T15:21:33.747Z",
    "dateUpdated": "2025-08-29T13:31:06.430Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2026-1638 (GCVE-0-2026-1638)

Vulnerability from cvelistv5 – Published: 2026-01-29 23:32 – Updated: 2026-01-30 18:25
VLAI?
Title
Tenda AC21 mDMZSetCfg command injection
Summary
A security flaw has been discovered in Tenda AC21 1.1.1.1/1.dmzip/16.03.08.16. The impacted element is the function mDMZSetCfg of the file /goform/mDMZSetCfg. The manipulation of the argument dmzIp results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks.
CWE
Assigner
References
https://vuldb.com/?id.343417 vdb-entrytechnical-description
https://vuldb.com/?ctiid.343417 signaturepermissions-required
https://vuldb.com/?submit.740871 third-party-advisory
https://github.com/LX-LX88/cve/issues/26 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 1.1.1.1
Affected: 1.dmzip
Affected: 16.03.08.16
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-1638",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T18:25:39.642410Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-30T18:25:59.761Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.1.1.1"
            },
            {
              "status": "affected",
              "version": "1.dmzip"
            },
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw has been discovered in Tenda AC21 1.1.1.1/1.dmzip/16.03.08.16. The impacted element is the function mDMZSetCfg of the file /goform/mDMZSetCfg. The manipulation of the argument dmzIp results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-29T23:32:11.350Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-343417 | Tenda AC21 mDMZSetCfg command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.343417"
        },
        {
          "name": "VDB-343417 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.343417"
        },
        {
          "name": "Submit #740871 | Tenda AC21 V16.03.08.16 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.740871"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/26"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-01-29T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-01-29T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-01-29T18:01:32.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 mDMZSetCfg command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-1638",
    "datePublished": "2026-01-29T23:32:11.350Z",
    "dateReserved": "2026-01-29T16:56:25.779Z",
    "dateUpdated": "2026-01-30T18:25:59.761Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-1637 (GCVE-0-2026-1637)

Vulnerability from cvelistv5 – Published: 2026-01-29 22:32 – Updated: 2026-02-02 16:33
VLAI?
Title
Tenda AC21 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow
Summary
A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CWE
Assigner
References
https://vuldb.com/?id.343416 vdb-entrytechnical-description
https://vuldb.com/?ctiid.343416 signaturepermissions-required
https://vuldb.com/?submit.740865 third-party-advisory
https://github.com/LX-LX88/cve/issues/25 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-1637",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T14:36:34.085802Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-02T16:33:53.523Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/LX-LX88/cve/issues/25"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-29T22:32:07.685Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-343416 | Tenda AC21 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.343416"
        },
        {
          "name": "VDB-343416 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.343416"
        },
        {
          "name": "Submit #740865 | Tenda AC21 V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.740865"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/25"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-01-29T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-01-29T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-01-29T18:01:30.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-1637",
    "datePublished": "2026-01-29T22:32:07.685Z",
    "dateReserved": "2026-01-29T16:56:17.581Z",
    "dateUpdated": "2026-02-02T16:33:53.523Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13446 (GCVE-0-2025-13446)

Vulnerability from cvelistv5 – Published: 2025-11-20 02:32 – Updated: 2025-11-20 14:52
VLAI?
Title
Tenda AC21 SetSysTimeCfg stack-based overflow
Summary
A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
jiahui288 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13446",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T14:16:02.059248Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T14:52:07.354Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN8.md"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN9.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jiahui288 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T02:32:07.969Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-333018 | Tenda AC21 SetSysTimeCfg stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.333018"
        },
        {
          "name": "VDB-333018 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.333018"
        },
        {
          "name": "Submit #694425 | Tenda AC21 V16.03.08.16  Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694425"
        },
        {
          "name": "Submit #694430 | Tenda AC21 V16.03.08.16  Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694430"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN8.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN9.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-19T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-19T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-19T20:19:45.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetSysTimeCfg stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-13446",
    "datePublished": "2025-11-20T02:32:07.969Z",
    "dateReserved": "2025-11-19T19:14:38.513Z",
    "dateUpdated": "2025-11-20T14:52:07.354Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-13445 (GCVE-0-2025-13445)

Vulnerability from cvelistv5 – Published: 2025-11-20 02:02 – Updated: 2025-11-20 14:52
VLAI?
Title
Tenda AC21 SetIpMacBind stack-based overflow
Summary
A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
jiahui288 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13445",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-20T14:17:02.610671Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-20T14:52:14.900Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN7.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jiahui288 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T02:02:09.585Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-333017 | Tenda AC21 SetIpMacBind stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.333017"
        },
        {
          "name": "VDB-333017 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.333017"
        },
        {
          "name": "Submit #694066 | Tenda AC21 V16.03.08.16  Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.694066"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN7.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-19T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-19T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-19T20:19:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetIpMacBind stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-13445",
    "datePublished": "2025-11-20T02:02:09.585Z",
    "dateReserved": "2025-11-19T19:14:36.023Z",
    "dateUpdated": "2025-11-20T14:52:14.900Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12611 (GCVE-0-2025-12611)

Vulnerability from cvelistv5 – Published: 2025-11-03 02:02 – Updated: 2025-11-03 14:26
VLAI?
Title
Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow
Summary
A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CWE
Assigner
References
https://vuldb.com/?id.330906 vdb-entrytechnical-description
https://vuldb.com/?ctiid.330906 signaturepermissions-required
https://vuldb.com/?submit.678491 third-party-advisory
https://github.com/LX-LX88/cve/issues/10 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12611",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T14:16:45.645981Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T14:26:36.736Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC21 16.03.08.16 wurde eine Schwachstelle gefunden. Es geht dabei um die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Mit der Manipulation des Arguments startIp mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-03T02:02:09.734Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-330906 | Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.330906"
        },
        {
          "name": "VDB-330906 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.330906"
        },
        {
          "name": "Submit #678491 | Tenda AC21 V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.678491"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/10"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-02T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-02T07:33:49.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-12611",
    "datePublished": "2025-11-03T02:02:09.734Z",
    "dateReserved": "2025-11-02T06:28:46.133Z",
    "dateUpdated": "2025-11-03T14:26:36.736Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-11091 (GCVE-0-2025-11091)

Vulnerability from cvelistv5 – Published: 2025-09-28 01:32 – Updated: 2025-09-29 14:48
VLAI?
Title
Tenda AC21 SetStaticRouteCfg sscanf buffer overflow
Summary
A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited.
CWE
Assigner
References
https://vuldb.com/?id.326173 vdb-entrytechnical-description
https://vuldb.com/?ctiid.326173 signaturepermissions-required
https://vuldb.com/?submit.661806 third-party-advisory
https://github.com/maximdevere/CVE2/issues/2 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.0
Affected: 16.03.08.1
Affected: 16.03.08.2
Affected: 16.03.08.3
Affected: 16.03.08.4
Affected: 16.03.08.5
Affected: 16.03.08.6
Affected: 16.03.08.7
Affected: 16.03.08.8
Affected: 16.03.08.9
Affected: 16.03.08.10
Affected: 16.03.08.11
Affected: 16.03.08.12
Affected: 16.03.08.13
Affected: 16.03.08.14
Affected: 16.03.08.15
Affected: 16.03.08.16
Create a notification for this product.
Credits
MaximDeVere (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11091",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-29T14:48:52.752774Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-29T14:48:57.508Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/maximdevere/CVE2/issues/2"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.0"
            },
            {
              "status": "affected",
              "version": "16.03.08.1"
            },
            {
              "status": "affected",
              "version": "16.03.08.2"
            },
            {
              "status": "affected",
              "version": "16.03.08.3"
            },
            {
              "status": "affected",
              "version": "16.03.08.4"
            },
            {
              "status": "affected",
              "version": "16.03.08.5"
            },
            {
              "status": "affected",
              "version": "16.03.08.6"
            },
            {
              "status": "affected",
              "version": "16.03.08.7"
            },
            {
              "status": "affected",
              "version": "16.03.08.8"
            },
            {
              "status": "affected",
              "version": "16.03.08.9"
            },
            {
              "status": "affected",
              "version": "16.03.08.10"
            },
            {
              "status": "affected",
              "version": "16.03.08.11"
            },
            {
              "status": "affected",
              "version": "16.03.08.12"
            },
            {
              "status": "affected",
              "version": "16.03.08.13"
            },
            {
              "status": "affected",
              "version": "16.03.08.14"
            },
            {
              "status": "affected",
              "version": "16.03.08.15"
            },
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "MaximDeVere (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC21 up to 16.03.08.16 entdeckt. Dabei geht es um die Funktion sscanf der Datei /goform/SetStaticRouteCfg. Dank Manipulation des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff l\u00e4sst sich \u00fcber das Netzwerk starten. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-28T01:32:10.696Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-326173 | Tenda AC21 SetStaticRouteCfg sscanf buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.326173"
        },
        {
          "name": "VDB-326173 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.326173"
        },
        {
          "name": "Submit #661806 | Shenzhen Tenda Technology Co.,Ltd. AC21 \u003c= V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.661806"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/maximdevere/CVE2/issues/2"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-09-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-09-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-09-27T07:31:48.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 SetStaticRouteCfg sscanf buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11091",
    "datePublished": "2025-09-28T01:32:10.696Z",
    "dateReserved": "2025-09-27T05:26:44.839Z",
    "dateUpdated": "2025-09-29T14:48:57.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-10838 (GCVE-0-2025-10838)

Vulnerability from cvelistv5 – Published: 2025-09-23 04:32 – Updated: 2025-09-23 19:12
VLAI?
Title
Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow
Summary
A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub_45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
QMSSDXN (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10838",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-23T19:12:21.343557Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-23T19:12:30.355Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "QMSSDXN (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub_45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC21 16.03.08.16 gefunden. Es geht dabei um die Funktion sub_45BB10 der Datei /goform/WifiExtraSet. Durch Manipulieren des Arguments wpapsk_crypto mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-23T04:32:07.071Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-325200 | Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.325200"
        },
        {
          "name": "VDB-325200 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.325200"
        },
        {
          "name": "Submit #657126 | Tenda AC21 \u2264V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.657126"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/lin-3-start/lin-cve/blob/main/Tenda%20AC21/Tenda%20AC21%20Buffer%20overflow.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/lin-3-start/lin-cve/blob/main/Tenda%20AC21/Tenda%20AC21%20Buffer%20overflow.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-09-22T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-09-22T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-09-22T07:15:16.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21 WifiExtraSet sub_45BB10 buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-10838",
    "datePublished": "2025-09-23T04:32:07.071Z",
    "dateReserved": "2025-09-22T05:10:13.621Z",
    "dateUpdated": "2025-09-23T19:12:30.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9605 (GCVE-0-2025-9605)

Vulnerability from cvelistv5 – Published: 2025-08-29 02:02 – Updated: 2025-08-29 13:31
VLAI?
Title
Tenda AC21/AC23 GetParentControlInfo stack-based overflow
Summary
A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
lxyilu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9605",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-29T13:31:03.332380Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-29T13:31:06.430Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        },
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "lxyilu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC21 and AC23 16.03.08.16 ist eine Schwachstelle entdeckt worden. Betroffen ist die Funktion GetParentControlInfo der Datei /goform/GetParentControlInfo. Durch das Manipulieren des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Ein Angriff ist aus der Distanz m\u00f6glich. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-29T02:02:08.778Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-321783 | Tenda AC21/AC23 GetParentControlInfo stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.321783"
        },
        {
          "name": "VDB-321783 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.321783"
        },
        {
          "name": "Submit #636545 | Tenda Wi-Fi 5 Router AC21 AC21V1.0re_V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636545"
        },
        {
          "name": "Submit #636548 | Tenda Wi-Fi 5 Router AC23 AC23V1.0re_V16.03.07.52 Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636548"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-08-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-08-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-08-28T17:27:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21/AC23 GetParentControlInfo stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-9605",
    "datePublished": "2025-08-29T02:02:08.778Z",
    "dateReserved": "2025-08-28T15:21:33.747Z",
    "dateUpdated": "2025-08-29T13:31:06.430Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

VAR-202511-2330

Vulnerability from variot - Updated: 2025-12-20 23:44

Shenzhen Tenda Technology Co.,Ltd. of ac21 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the fact that the urls parameter in the /goform/saveParentControlInfo file fails to properly validate the length of input data. Attackers can exploit this vulnerability to cause a denial-of-service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202511-2330",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac21  firmware  16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.08.16"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29425"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020360"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65223"
      }
    ]
  },
  "cve": "CVE-2025-65223",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 3.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2025-29425",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-65223",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "OTHER",
            "availabilityImpact": "Low",
            "baseScore": 4.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-020360",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2025-65223",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-020360",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-29425",
            "trust": 0.6,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29425"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020360"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65223"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen Tenda Technology Co.,Ltd. of ac21 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the fact that the `urls` parameter in the `/goform/saveParentControlInfo` file fails to properly validate the length of input data. Attackers can exploit this vulnerability to cause a denial-of-service attack",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020360"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29425"
      }
    ],
    "trust": 1.26
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-65223",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020360",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29425",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29425"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020360"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65223"
      }
    ]
  },
  "id": "VAR-202511-2330",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29425"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29425"
      }
    ]
  },
  "last_update_date": "2025-12-20T23:44:52.161000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020360"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65223"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/madgeaaaaa/my_vuln_2/blob/main/tenda/vuln4.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-65223"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29425"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020360"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65223"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29425"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020360"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65223"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29425"
      },
      {
        "date": "2025-11-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-020360"
      },
      {
        "date": "2025-11-20T15:17:40.440000",
        "db": "NVD",
        "id": "CVE-2025-65223"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29425"
      },
      {
        "date": "2025-11-27T23:37:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-020360"
      },
      {
        "date": "2025-11-21T17:25:10.917000",
        "db": "NVD",
        "id": "CVE-2025-65223"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac21\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020360"
      }
    ],
    "trust": 0.8
  }
}

VAR-202511-2269

Vulnerability from variot - Updated: 2025-12-20 23:44

A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. of ac21 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the /goform/SetSysTimeCfg file, where the parameter timeZone/time fails to properly validate the length of input data. Attackers could exploit this vulnerability to execute arbitrary code or cause a denial-of-service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202511-2269",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac21  firmware  16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.08.16"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020400"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13446"
      }
    ]
  },
  "cve": "CVE-2025-13446",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2025-13446",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-020400",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2025-29427",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-13446",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2025-13446",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-020400",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-13446",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2025-13446",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-020400",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-29427",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020400"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13446"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13446"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. of ac21 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the `/goform/SetSysTimeCfg` file, where the parameter `timeZone/time` fails to properly validate the length of input data. Attackers could exploit this vulnerability to execute arbitrary code or cause a denial-of-service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-13446"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020400"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29427"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-13446",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "333018",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020400",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29427",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020400"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13446"
      }
    ]
  },
  "id": "VAR-202511-2269",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29427"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29427"
      }
    ]
  },
  "last_update_date": "2025-12-20T23:44:29.620000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Buffer error (CWE-119) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020400"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13446"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/madgeaaaaa/my_vuln_2/blob/main/tenda/vuln8.md"
      },
      {
        "trust": 1.8,
        "url": "https://github.com/madgeaaaaa/my_vuln_2/blob/main/tenda/vuln9.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.333018"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.694425"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.694430"
      },
      {
        "trust": 1.8,
        "url": "https://www.tenda.com.cn/"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.333018"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-13446"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020400"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13446"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29427"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020400"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13446"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29427"
      },
      {
        "date": "2025-11-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-020400"
      },
      {
        "date": "2025-11-20T15:17:25.713000",
        "db": "NVD",
        "id": "CVE-2025-13446"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29427"
      },
      {
        "date": "2025-11-27T23:38:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-020400"
      },
      {
        "date": "2025-11-21T20:16:29.907000",
        "db": "NVD",
        "id": "CVE-2025-13446"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac21\u00a0 Buffer error vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020400"
      }
    ],
    "trust": 0.8
  }
}

VAR-202511-2366

Vulnerability from variot - Updated: 2025-12-20 23:35

Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the list parameter of /goform/setPptpUserList. Shenzhen Tenda Technology Co.,Ltd. of ac21 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the fact that the list parameter in /goform/setPptpUserList fails to properly validate the length of the input data. Attackers can exploit this vulnerability to cause a denial-of-service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202511-2366",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac21  firmware  16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.08.16"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29422"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020361"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65221"
      }
    ]
  },
  "cve": "CVE-2025-65221",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 3.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2025-29422",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-65221",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "OTHER",
            "availabilityImpact": "Low",
            "baseScore": 4.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-020361",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2025-65221",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-020361",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-29422",
            "trust": 0.6,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29422"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020361"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65221"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow via the list parameter of /goform/setPptpUserList. Shenzhen Tenda Technology Co.,Ltd. of ac21 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the fact that the `list` parameter in `/goform/setPptpUserList` fails to properly validate the length of the input data. Attackers can exploit this vulnerability to cause a denial-of-service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-65221"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020361"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29422"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-65221",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020361",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29422",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29422"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020361"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65221"
      }
    ]
  },
  "id": "VAR-202511-2366",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29422"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29422"
      }
    ]
  },
  "last_update_date": "2025-12-20T23:35:27.958000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020361"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65221"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/madgeaaaaa/my_vuln_2/blob/main/tenda/vuln2.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-65221"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29422"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020361"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65221"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29422"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020361"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65221"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29422"
      },
      {
        "date": "2025-11-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-020361"
      },
      {
        "date": "2025-11-20T15:17:40.160000",
        "db": "NVD",
        "id": "CVE-2025-65221"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29422"
      },
      {
        "date": "2025-11-27T23:37:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-020361"
      },
      {
        "date": "2025-11-21T17:25:39.963000",
        "db": "NVD",
        "id": "CVE-2025-65221"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac21\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-020361"
      }
    ],
    "trust": 0.8
  }
}

VAR-202509-1846

Vulnerability from variot - Updated: 2025-12-20 23:22

A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub_45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. Shenzhen Tenda Technology Co.,Ltd. of ac21 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability stems from the fact that the parameter wpapsk_crypto in the function sub_45BB10 within the file /goform/WifiExtraSet fails to properly validate the length of the input data. Attackers could exploit this vulnerability to execute arbitrary code or cause a denial-of-service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202509-1846",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac21  firmware  16.03.08.16  and earlier"
      },
      {
        "model": "ac21",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "16.03.08.16"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-30948"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015558"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-10838"
      }
    ]
  },
  "cve": "CVE-2025-10838",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2025-10838",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-015558",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2025-30948",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-10838",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-015558",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-10838",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-015558",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-30948",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-30948"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015558"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-10838"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function sub_45BB10 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. Shenzhen Tenda Technology Co.,Ltd. of ac21 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability stems from the fact that the parameter `wpapsk_crypto` in the function `sub_45BB10` within the file `/goform/WifiExtraSet` fails to properly validate the length of the input data. Attackers could exploit this vulnerability to execute arbitrary code or cause a denial-of-service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-10838"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015558"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-30948"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-10838",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "325200",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015558",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-30948",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-30948"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015558"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-10838"
      }
    ]
  },
  "id": "VAR-202509-1846",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-30948"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-30948"
      }
    ]
  },
  "last_update_date": "2025-12-20T23:22:57.907000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Buffer error (CWE-119) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Classic buffer overflow (CWE-120) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015558"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-10838"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/lin-3-start/lin-cve/blob/main/tenda%20ac21/tenda%20ac21%20buffer%20overflow.md"
      },
      {
        "trust": 1.8,
        "url": "https://github.com/lin-3-start/lin-cve/blob/main/tenda%20ac21/tenda%20ac21%20buffer%20overflow.md#poc"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.325200"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.657126"
      },
      {
        "trust": 1.8,
        "url": "https://www.tenda.com.cn/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-10838"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.325200"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-30948"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015558"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-10838"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-30948"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015558"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-10838"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-12-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-30948"
      },
      {
        "date": "2025-10-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-015558"
      },
      {
        "date": "2025-09-23T05:15:35.010000",
        "db": "NVD",
        "id": "CVE-2025-10838"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-12-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-30948"
      },
      {
        "date": "2025-10-09T08:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-015558"
      },
      {
        "date": "2025-10-03T15:09:55.663000",
        "db": "NVD",
        "id": "CVE-2025-10838"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac21\u00a0 Buffer error vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015558"
      }
    ],
    "trust": 0.8
  }
}

VAR-202511-2233

Vulnerability from variot - Updated: 2025-11-28 23:23

A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used. Shenzhen Tenda Technology Co.,Ltd. of ac21 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the /goform/SetIpMacBind file's parameter list failing to properly validate the length of input data. Attackers could exploit this vulnerability to execute arbitrary code or cause a denial-of-service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202511-2233",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac21  firmware  16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.08.16"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29428"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019938"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13445"
      }
    ]
  },
  "cve": "CVE-2025-13445",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2025-13445",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-019938",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2025-29428",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-13445",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2025-13445",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-019938",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-13445",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2025-13445",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-019938",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-29428",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29428"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019938"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13445"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13445"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used. Shenzhen Tenda Technology Co.,Ltd. of ac21 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the `/goform/SetIpMacBind` file\u0027s parameter `list` failing to properly validate the length of input data. Attackers could exploit this vulnerability to execute arbitrary code or cause a denial-of-service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-13445"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019938"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29428"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-13445",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "333017",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019938",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29428",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29428"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019938"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13445"
      }
    ]
  },
  "id": "VAR-202511-2233",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29428"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29428"
      }
    ]
  },
  "last_update_date": "2025-11-28T23:23:58.531000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Buffer error (CWE-119) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019938"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13445"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/madgeaaaaa/my_vuln_2/blob/main/tenda/vuln7.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.333017"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.694066"
      },
      {
        "trust": 1.8,
        "url": "https://www.tenda.com.cn/"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.333017"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-13445"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29428"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019938"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13445"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29428"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019938"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-13445"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29428"
      },
      {
        "date": "2025-11-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-019938"
      },
      {
        "date": "2025-11-20T15:17:25.480000",
        "db": "NVD",
        "id": "CVE-2025-13445"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29428"
      },
      {
        "date": "2025-11-26T02:18:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-019938"
      },
      {
        "date": "2025-11-21T20:19:44.090000",
        "db": "NVD",
        "id": "CVE-2025-13445"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac21\u00a0 Buffer error vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019938"
      }
    ],
    "trust": 0.8
  }
}

VAR-202511-2296

Vulnerability from variot - Updated: 2025-11-28 23:23

Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow in: /goform/SetVirtualServerCfg via the list parameter. Shenzhen Tenda Technology Co.,Ltd. of ac21 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the fact that the list parameter in /goform/SetVirtualServerCfg fails to properly validate the length of input data. Attackers can exploit this vulnerability to cause a denial-of-service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202511-2296",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac21  firmware  16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.08.16"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29424"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019954"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65220"
      }
    ]
  },
  "cve": "CVE-2025-65220",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 3.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2025-29424",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-65220",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "OTHER",
            "availabilityImpact": "Low",
            "baseScore": 4.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-019954",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2025-65220",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-019954",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-29424",
            "trust": 0.6,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29424"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019954"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65220"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow in: /goform/SetVirtualServerCfg via the list parameter. Shenzhen Tenda Technology Co.,Ltd. of ac21 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the fact that the `list` parameter in `/goform/SetVirtualServerCfg` fails to properly validate the length of input data. Attackers can exploit this vulnerability to cause a denial-of-service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-65220"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019954"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29424"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-65220",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019954",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29424",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29424"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019954"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65220"
      }
    ]
  },
  "id": "VAR-202511-2296",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29424"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29424"
      }
    ]
  },
  "last_update_date": "2025-11-28T23:23:58.509000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019954"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65220"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/madgeaaaaa/my_vuln_2/blob/main/tenda/vuln1.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-65220"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29424"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019954"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65220"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29424"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019954"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65220"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29424"
      },
      {
        "date": "2025-11-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-019954"
      },
      {
        "date": "2025-11-20T15:17:40.010000",
        "db": "NVD",
        "id": "CVE-2025-65220"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29424"
      },
      {
        "date": "2025-11-26T02:32:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-019954"
      },
      {
        "date": "2025-11-21T17:26:01.583000",
        "db": "NVD",
        "id": "CVE-2025-65220"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac21\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019954"
      }
    ],
    "trust": 0.8
  }
}

VAR-202511-2359

Vulnerability from variot - Updated: 2025-11-28 23:23

Shenzhen Tenda Technology Co.,Ltd. of ac21 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the fact that the rebootTime parameter in /goform/SetSysAutoRebbotCfg fails to properly validate the length of the input data. Attackers can exploit this vulnerability to cause a denial-of-service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202511-2359",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac21  firmware  16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.08.16"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29426"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019953"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65222"
      }
    ]
  },
  "cve": "CVE-2025-65222",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 3.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2025-29426",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-65222",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "OTHER",
            "availabilityImpact": "Low",
            "baseScore": 4.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-019953",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2025-65222",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-019953",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-29426",
            "trust": 0.6,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29426"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019953"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65222"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen Tenda Technology Co.,Ltd. of ac21 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. This vulnerability stems from the fact that the rebootTime parameter in `/goform/SetSysAutoRebbotCfg` fails to properly validate the length of the input data. Attackers can exploit this vulnerability to cause a denial-of-service attack",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019953"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29426"
      }
    ],
    "trust": 1.26
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-65222",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019953",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29426",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29426"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019953"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65222"
      }
    ]
  },
  "id": "VAR-202511-2359",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29426"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29426"
      }
    ]
  },
  "last_update_date": "2025-11-28T23:23:58.454000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019953"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65222"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/madgeaaaaa/my_vuln_2/blob/main/tenda/vuln3.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-65222"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29426"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019953"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65222"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29426"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019953"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65222"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29426"
      },
      {
        "date": "2025-11-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-019953"
      },
      {
        "date": "2025-11-20T15:17:40.297000",
        "db": "NVD",
        "id": "CVE-2025-65222"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29426"
      },
      {
        "date": "2025-11-26T02:32:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-019953"
      },
      {
        "date": "2025-11-21T17:25:23.817000",
        "db": "NVD",
        "id": "CVE-2025-65222"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac21\u00a0 Stack-based buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019953"
      }
    ],
    "trust": 0.8
  }
}

VAR-202511-2355

Vulnerability from variot - Updated: 2025-11-28 23:14

Shenzhen Tenda Technology Co.,Ltd. of ac21 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming.

The Tenda AC21 contains a buffer overflow vulnerability. This vulnerability stems from the fact that the deviceId parameter in the /goform/saveParentControlInfo file fails to properly validate the length of input data. Attackers can exploit this vulnerability to cause a denial-of-service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202511-2355",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac21  firmware  16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.08.16"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29423"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019952"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65226"
      }
    ]
  },
  "cve": "CVE-2025-65226",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 3.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2025-29423",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-65226",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "OTHER",
            "availabilityImpact": "Low",
            "baseScore": 4.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-019952",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2025-65226",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-019952",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-29423",
            "trust": 0.6,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29423"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019952"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65226"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen Tenda Technology Co.,Ltd. of ac21 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. The Tenda AC21 is a dual-band gigabit wireless router from Tenda Technology, designed for high-speed home internet needs. It supports 802.11ac wave2 technology, with a dual-band concurrent speed of up to 2033Mbps, including 1733Mbps on the 5GHz band, meeting the demands of high-bandwidth applications such as 4K video and live streaming. \n\nThe Tenda AC21 contains a buffer overflow vulnerability. This vulnerability stems from the fact that the deviceId parameter in the /goform/saveParentControlInfo file fails to properly validate the length of input data. Attackers can exploit this vulnerability to cause a denial-of-service attack",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019952"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29423"
      }
    ],
    "trust": 1.26
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-65226",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019952",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29423",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29423"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019952"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65226"
      }
    ]
  },
  "id": "VAR-202511-2355",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29423"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29423"
      }
    ]
  },
  "last_update_date": "2025-11-28T23:14:47.418000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019952"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65226"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/madgeaaaaa/my_vuln_2/blob/main/tenda/vuln5.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-65226"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29423"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019952"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65226"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29423"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019952"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-65226"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29423"
      },
      {
        "date": "2025-11-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-019952"
      },
      {
        "date": "2025-11-20T15:17:40.577000",
        "db": "NVD",
        "id": "CVE-2025-65226"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29423"
      },
      {
        "date": "2025-11-26T02:32:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-019952"
      },
      {
        "date": "2025-11-21T17:24:54.497000",
        "db": "NVD",
        "id": "CVE-2025-65226"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac21\u00a0 Classic buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-019952"
      }
    ],
    "trust": 0.8
  }
}

VAR-202511-0056

Vulnerability from variot - Updated: 2025-11-19 23:27

A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. An attacker could exploit this vulnerability to remotely manipulate the parameter, triggering a buffer overflow that could then execute arbitrary code or cause system crashes

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202511-0056",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "16.03.08.16"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-27230"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-12611"
      }
    ]
  },
  "cve": "CVE-2025-12611",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2025-12611",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2025-27230",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-12611",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2025-12611",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-12611",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2025-12611",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-27230",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-27230"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-12611"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-12611"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. An attacker could exploit this vulnerability to remotely manipulate the parameter, triggering a buffer overflow that could then execute arbitrary code or cause system crashes",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-12611"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-27230"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "VULDB",
        "id": "330906",
        "trust": 1.6
      },
      {
        "db": "NVD",
        "id": "CVE-2025-12611",
        "trust": 1.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-27230",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-27230"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-12611"
      }
    ]
  },
  "id": "VAR-202511-0056",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-27230"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-27230"
      }
    ]
  },
  "last_update_date": "2025-11-19T23:27:40.167000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-12611"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://vuldb.com/?id.330906"
      },
      {
        "trust": 1.6,
        "url": "https://vuldb.com/?ctiid.330906"
      },
      {
        "trust": 1.6,
        "url": "https://vuldb.com/?submit.678491"
      },
      {
        "trust": 1.6,
        "url": "https://github.com/lx-lx88/cve/issues/10"
      },
      {
        "trust": 1.6,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-27230"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-12611"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-27230"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-12611"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-27230"
      },
      {
        "date": "2025-11-03T03:15:40.760000",
        "db": "NVD",
        "id": "CVE-2025-12611"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-27230"
      },
      {
        "date": "2025-11-05T16:09:23.787000",
        "db": "NVD",
        "id": "CVE-2025-12611"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC21 buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-27230"
      }
    ],
    "trust": 0.6
  }
}

VAR-202509-3845

Vulnerability from variot - Updated: 2025-10-12 23:23

A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited. Shenzhen Tenda Technology Co.,Ltd. of ac21 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202509-3845",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac21  firmware  16.03.08.16  and earlier"
      },
      {
        "model": "ac21",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015760"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-11091"
      }
    ]
  },
  "cve": "CVE-2025-11091",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2025-11091",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-015760",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2025-11091",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-015760",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-11091",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-015760",
            "trust": 0.8,
            "value": "High"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015760"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-11091"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited. Shenzhen Tenda Technology Co.,Ltd. of ac21 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-11091"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015760"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-11091",
        "trust": 2.6
      },
      {
        "db": "VULDB",
        "id": "326173",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015760",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015760"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-11091"
      }
    ]
  },
  "id": "VAR-202509-3845",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.55
  },
  "last_update_date": "2025-10-12T23:23:43.974000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-119",
        "trust": 1.0
      },
      {
        "problemtype": "Buffer error (CWE-119) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Classic buffer overflow (CWE-120) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015760"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-11091"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/maximdevere/cve2/issues/2"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.326173"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.661806"
      },
      {
        "trust": 1.8,
        "url": "https://www.tenda.com.cn/"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.326173"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-11091"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015760"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-11091"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015760"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-11091"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-10-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-015760"
      },
      {
        "date": "2025-09-28T02:15:31.430000",
        "db": "NVD",
        "id": "CVE-2025-11091"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-10-10T08:06:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-015760"
      },
      {
        "date": "2025-10-03T14:45:31.690000",
        "db": "NVD",
        "id": "CVE-2025-11091"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac21\u00a0 Buffer error vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-015760"
      }
    ],
    "trust": 0.8
  }
}

VAR-202508-2393

Vulnerability from variot - Updated: 2025-09-07 23:18

A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used. Shenzhen Tenda Technology Co.,Ltd. of ac21 firmware and ac23 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202508-2393",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.16"
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.16"
      },
      {
        "model": "ac21",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-012874"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-9605"
      }
    ]
  },
  "cve": "CVE-2025-9605",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2025-9605",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 10.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-012874",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2025-9605",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-012874",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2025-9605",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-012874",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-012874"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-9605"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used. Shenzhen Tenda Technology Co.,Ltd. of ac21 firmware and ac23 The firmware contains a buffer error vulnerability and a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-9605"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-012874"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-9605",
        "trust": 2.6
      },
      {
        "db": "VULDB",
        "id": "321783",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-012874",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-012874"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-9605"
      }
    ]
  },
  "id": "VAR-202508-2393",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.5
  },
  "last_update_date": "2025-09-07T23:18:19.580000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Buffer error (CWE-119) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-012874"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-9605"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/xxricardo/iot-cve/blob/main/tenda/ac21/ac21v1.0re_v16.03.08.16.md"
      },
      {
        "trust": 1.8,
        "url": "https://github.com/xxricardo/iot-cve/blob/main/tenda/ac23/stack-based%20buffer%20overflow%20in%20tenda%20wi-fi%205%20router%20ac23%ef%bc%88ac23v1.0re_v16.03.07.52%ef%bc%89.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.321783"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.636545"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.636548"
      },
      {
        "trust": 1.8,
        "url": "https://www.tenda.com.cn/"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.321783"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-9605"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-012874"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-9605"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-012874"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-9605"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-09-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-012874"
      },
      {
        "date": "2025-08-29T03:15:40.140000",
        "db": "NVD",
        "id": "CVE-2025-9605"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-09-04T05:51:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-012874"
      },
      {
        "date": "2025-09-03T16:10:04.083000",
        "db": "NVD",
        "id": "CVE-2025-9605"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac21\u00a0 firmware and \u00a0ac23\u00a0 Buffer error vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-012874"
      }
    ],
    "trust": 0.8
  }
}

VAR-202211-1367

Vulnerability from variot - Updated: 2025-04-30 23:09

Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function via set_device_name. Tenda AC21 is a wireless router made by China Tenda Company. The vulnerability stems from the fact that its set_device_name function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1367",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.15"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.08.15"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87031"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44158"
      }
    ]
  },
  "cve": "CVE-2022-44158",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-87031",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-44158",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-44158",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2022-44158",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-87031",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-3202",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87031"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3202"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44158"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44158"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function via set_device_name. Tenda AC21 is a wireless router made by China Tenda Company. The vulnerability stems from the fact that its set_device_name function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44158"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87031"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-44158",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87031",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3202",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87031"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3202"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44158"
      }
    ]
  },
  "id": "VAR-202211-1367",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87031"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87031"
      }
    ]
  },
  "last_update_date": "2025-04-30T23:09:51.739000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44158"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://drive.google.com/file/d/11pssuplmlcl0-eo565tlbvavzfp5awdg/view?usp=sharing"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-44158/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87031"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3202"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44158"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87031"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3202"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44158"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87031"
      },
      {
        "date": "2022-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3202"
      },
      {
        "date": "2022-11-21T16:15:25.863000",
        "db": "NVD",
        "id": "CVE-2022-44158"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87031"
      },
      {
        "date": "2022-11-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3202"
      },
      {
        "date": "2025-04-29T17:15:37.350000",
        "db": "NVD",
        "id": "CVE-2022-44158"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3202"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC21 set_device_name function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87031"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3202"
      }
    ],
    "trust": 0.6
  }
}

VAR-202211-1291

Vulnerability from variot - Updated: 2025-04-30 02:52

Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function formSetMacFilterCfg. Tenda AC21 is a wireless router made by China Tenda Company. The vulnerability comes from the fact that its formSetMacFilterCfg function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-1291",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.15"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.08.15"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87030"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44163"
      }
    ]
  },
  "cve": "CVE-2022-44163",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-87030",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-44163",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-44163",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2022-44163",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-87030",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-3201",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87030"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3201"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44163"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44163"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function formSetMacFilterCfg. Tenda AC21 is a wireless router made by China Tenda Company. The vulnerability comes from the fact that its formSetMacFilterCfg function does not check the length of the input data. Attackers can exploit the vulnerability to cause denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44163"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87030"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-44163",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-87030",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3201",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87030"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3201"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44163"
      }
    ]
  },
  "id": "VAR-202211-1291",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87030"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87030"
      }
    ]
  },
  "last_update_date": "2025-04-30T02:52:43.170000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-44163"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://drive.google.com/file/d/1jmwnxvkc-hfsiudnapgx_exbytcalssk/view?usp=sharing"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-44163/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87030"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3201"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44163"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87030"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3201"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-44163"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87030"
      },
      {
        "date": "2022-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3201"
      },
      {
        "date": "2022-11-21T16:15:25.910000",
        "db": "NVD",
        "id": "CVE-2022-44163"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-87030"
      },
      {
        "date": "2022-12-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-3201"
      },
      {
        "date": "2025-04-29T16:15:26.903000",
        "db": "NVD",
        "id": "CVE-2022-44163"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3201"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC21 formSetMacFilterCfg function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-87030"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-3201"
      }
    ],
    "trust": 0.6
  }
}

VAR-202402-2784

Vulnerability from variot - Updated: 2025-03-28 23:05

A stack overflow vulnerability in Tenda AC21 with firmware version US_AC21V1.0re_V16.03.08.15_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/openSchedWifi. Shenzhen Tenda Technology Co.,Ltd. of ac21 A code injection vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202402-2784",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.08.15"
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac21  firmware  16.03.08.15"
      },
      {
        "model": "ac21",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac21",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-028489"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24333"
      }
    ]
  },
  "cve": "CVE-2023-24333",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2023-24333",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2023-028489",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2023-24333",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2023-028489",
            "trust": 0.8,
            "value": "High"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-028489"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24333"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A stack overflow vulnerability in Tenda AC21 with firmware version US_AC21V1.0re_V16.03.08.15_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/openSchedWifi. Shenzhen Tenda Technology Co.,Ltd. of ac21 A code injection vulnerability exists in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-24333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-028489"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-24333",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-028489",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-028489"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24333"
      }
    ]
  },
  "id": "VAR-202402-2784",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.55
  },
  "last_update_date": "2025-03-28T23:05:53.420000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-94",
        "trust": 1.0
      },
      {
        "problemtype": "Code injection (CWE-94) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-028489"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24333"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/caoyebo/cve/tree/main/tenda%20ac21%20-%20cve-2023-24333"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-24333"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-028489"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24333"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-028489"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-24333"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-028489"
      },
      {
        "date": "2024-02-21T21:15:08.673000",
        "db": "NVD",
        "id": "CVE-2023-24333"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-03-26T08:13:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-028489"
      },
      {
        "date": "2025-03-25T16:45:01.167000",
        "db": "NVD",
        "id": "CVE-2023-24333"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac21\u00a0 Code injection vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-028489"
      }
    ],
    "trust": 0.8
  }
}