Search criteria
36 vulnerabilities found for ac10u_firmware by tenda
CVE-2025-15218 (GCVE-0-2025-15218)
Vulnerability from nvd – Published: 2025-12-30 03:32 – Updated: 2025-12-30 15:37
VLAI?
Title
Tenda AC10U POST Request Parameter AdvSetLanip fromadvsetlanip buffer overflow
Summary
A weakness has been identified in Tenda AC10U 15.03.06.48/15.03.06.49. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Parameter Handler. Executing manipulation of the argument lanMask can lead to buffer overflow. The attack can be launched remotely. The exploit has been made available to the public and could be exploited.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
yhryhryhr_miemie (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-15218",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-30T15:37:49.540670Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T15:37:55.493Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"POST Request Parameter Handler"
],
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
},
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Tenda AC10U 15.03.06.48/15.03.06.49. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Parameter Handler. Executing manipulation of the argument lanMask can lead to buffer overflow. The attack can be launched remotely. The exploit has been made available to the public and could be exploited."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T03:32:08.254Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-338603 | Tenda AC10U POST Request Parameter AdvSetLanip fromadvsetlanip buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.338603"
},
{
"name": "VDB-338603 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.338603"
},
{
"name": "Submit #725461 | Tenda AC10U AC10U v1.0 Firmware V15.03.06.48\u3001AC10U v1.0 Firmware V15.03.06.49 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.725461"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC10U-fromadvsetlanip-2d753a41781f800c86c8d388a38e8101?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-12-28T16:44:13.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U POST Request Parameter AdvSetLanip fromadvsetlanip buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-15218",
"datePublished": "2025-12-30T03:32:08.254Z",
"dateReserved": "2025-12-28T15:39:08.350Z",
"dateUpdated": "2025-12-30T15:37:55.493Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-15215 (GCVE-0-2025-15215)
Vulnerability from nvd – Published: 2025-12-30 02:02 – Updated: 2025-12-30 18:46
VLAI?
Title
Tenda AC10U HTTP POST Request setPptpUserList formSetPPTPUserList buffer overflow
Summary
A vulnerability was determined in Tenda AC10U 15.03.06.48/15.03.06.49. This affects the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
yhryhryhr_miemie (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-15215",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-30T18:46:07.805035Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T18:46:13.307Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP POST Request Handler"
],
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
},
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda AC10U 15.03.06.48/15.03.06.49. This affects the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T02:02:08.414Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-338600 | Tenda AC10U HTTP POST Request setPptpUserList formSetPPTPUserList buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.338600"
},
{
"name": "VDB-338600 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.338600"
},
{
"name": "Submit #725365 | Tenda AC10U AC10U v1.0 Firmware V15.03.06.48\u3001AC10U v1.0 Firmware V15.03.06.49 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.725365"
},
{
"tags": [
"exploit"
],
"url": "https://www.notion.so/Tenda-AC10U-setPptpUserList-2d753a41781f80e8ba6bc37ba6100343?pvs=73"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-12-28T14:25:27.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U HTTP POST Request setPptpUserList formSetPPTPUserList buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-15215",
"datePublished": "2025-12-30T02:02:08.414Z",
"dateReserved": "2025-12-28T13:20:24.218Z",
"dateUpdated": "2025-12-30T18:46:13.307Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-10280 (GCVE-0-2024-10280)
Vulnerability from nvd – Published: 2024-10-23 13:31 – Updated: 2024-10-23 17:41
VLAI?
Title
Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
6.5 (Medium)
6.5 (Medium)
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
minipython (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac6_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.23"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac8_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.34.06"
}
]
},
{
"cpes": [
"cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac8_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.34.09"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.48.23"
},
{
"status": "affected",
"version": "16.03.48.19"
},
{
"status": "affected",
"version": "16.03.48.20"
},
{
"status": "affected",
"version": "16.03.48.13"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac1206_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.23"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac9_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.42"
},
{
"status": "affected",
"version": "15.03.05.19\\(6318_\\)"
},
{
"status": "affected",
"version": "15.03.05.14"
},
{
"status": "affected",
"version": "15.03.2.13"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19\\(6318\\)"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9\\(1307\\)"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.16"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.14"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac7_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac15_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.18"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac15_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10280",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T17:28:19.760214Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T17:41:57.370Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC8",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC15",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC1206",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "minipython (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T13:31:07.315Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.281555"
},
{
"name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.281555"
},
{
"name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.426417"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-10-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-10-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-10-23T08:07:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10280",
"datePublished": "2024-10-23T13:31:07.315Z",
"dateReserved": "2024-10-23T06:02:03.363Z",
"dateUpdated": "2024-10-23T17:41:57.370Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32306 (GCVE-0-2024-32306)
Vulnerability from nvd – Published: 2024-04-17 00:00 – Updated: 2024-08-02 02:06
VLAI?
Summary
Tenda AC10U v1.0 Firmware v15.03.06.49 has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
Severity ?
5.7 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49_multi_tde01"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-32306",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-22T19:47:47.493454Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:52:00.063Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:06:44.042Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/fromWizardHandle.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda AC10U v1.0 Firmware v15.03.06.49 has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T13:29:57.568081",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/fromWizardHandle.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-32306",
"datePublished": "2024-04-17T00:00:00",
"dateReserved": "2024-04-12T00:00:00",
"dateUpdated": "2024-08-02T02:06:44.042Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30612 (GCVE-0-2024-30612)
Vulnerability from nvd – Published: 2024-03-28 00:00 – Updated: 2024-08-02 01:39
VLAI?
Summary
Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function.
Severity ?
8.1 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.48_multi_tde01:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tendacn",
"versions": [
{
"status": "affected",
"version": "15.03.06.48_multi_tde01"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-30612",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T16:00:40.817506Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T15:01:51.898Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:39:00.652Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetClientState.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-28T14:54:46.377312",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetClientState.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-30612",
"datePublished": "2024-03-28T00:00:00",
"dateReserved": "2024-03-27T00:00:00",
"dateUpdated": "2024-08-02T01:39:00.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2853 (GCVE-0-2024-2853)
Vulnerability from nvd – Published: 2024-03-24 05:00 – Updated: 2024-08-01 19:25
VLAI?
Title
Tenda AC10U setsambacfg formSetSambaConf os command injection
Summary
A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-78 - OS Command Injection
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
wxhwxhwxh_miemie (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
"cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.48_multi_tde01:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tendacn",
"versions": [
{
"status": "affected",
"version": "15.03.06.48_multi_tde01"
},
{
"status": "affected",
"version": "15.03.06.49_multi_tde01"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2853",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-25T14:19:55.063616Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T18:29:31.431Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:42.158Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257777 | Tenda AC10U setsambacfg formSetSambaConf os command injection",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257777"
},
{
"name": "VDB-257777 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257777"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
},
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC10U 15.03.06.48/15.03.06.49 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formSetSambaConf der Datei /goform/setsambacfg. Durch die Manipulation des Arguments usbName mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-24T05:00:06.892Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257777 | Tenda AC10U setsambacfg formSetSambaConf os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257777"
},
{
"name": "VDB-257777 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257777"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-23T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-23T06:52:17.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U setsambacfg formSetSambaConf os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2853",
"datePublished": "2024-03-24T05:00:06.892Z",
"dateReserved": "2024-03-23T05:47:14.178Z",
"dateUpdated": "2024-08-01T19:25:42.158Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2764 (GCVE-0-2024-2764)
Vulnerability from nvd – Published: 2024-03-21 20:31 – Updated: 2024-08-02 13:57
VLAI?
Title
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_miemie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:41.687Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257601 | Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257601"
},
{
"name": "VDB-257601 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257601"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetPPTPServer.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.48_multi_tde01:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tendacn",
"versions": [
{
"status": "affected",
"version": "15.03.06.48_multi_tde01"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2764",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-22T14:41:42.917825Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-02T13:57:14.115Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.48 gefunden. Hiervon betroffen ist die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Durch die Manipulation des Arguments endIP mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-21T20:31:05.130Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257601 | Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257601"
},
{
"name": "VDB-257601 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257601"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetPPTPServer.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-21T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-21T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-21T16:22:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2764",
"datePublished": "2024-03-21T20:31:05.130Z",
"dateReserved": "2024-03-21T15:17:47.961Z",
"dateUpdated": "2024-08-02T13:57:14.115Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2763 (GCVE-0-2024-2763)
Vulnerability from nvd – Published: 2024-03-21 20:31 – Updated: 2024-08-01 19:25
VLAI?
Title
Tenda AC10U setcfm formSetCfm stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_miemie (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2763",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-22T17:49:42.492927Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T17:21:16.064Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:41.329Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257600 | Tenda AC10U setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257600"
},
{
"name": "VDB-257600 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257600"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetCfm.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.48 entdeckt. Davon betroffen ist die Funktion formSetCfm der Datei goform/setcfm. Mit der Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-21T20:31:03.792Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257600 | Tenda AC10U setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257600"
},
{
"name": "VDB-257600 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257600"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetCfm.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-21T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-21T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-21T16:22:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2763",
"datePublished": "2024-03-21T20:31:03.792Z",
"dateReserved": "2024-03-21T15:17:45.636Z",
"dateUpdated": "2024-08-01T19:25:41.329Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2711 (GCVE-0-2024-2711)
Vulnerability from nvd – Published: 2024-03-20 18:00 – Updated: 2024-08-21 22:56
VLAI?
Title
Tenda AC10U addWifiMacFilter stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.437Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257462 | Tenda AC10U addWifiMacFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257462"
},
{
"name": "VDB-257462 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257462"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/addWifiMacFilter_deviceMac.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2711",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-20T19:33:40.489082Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T22:56:23.392Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.48 ausgemacht. Dies betrifft die Funktion addWifiMacFilter der Datei /goform/addWifiMacFilter. Durch das Manipulieren des Arguments deviceMac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T18:00:08.616Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257462 | Tenda AC10U addWifiMacFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257462"
},
{
"name": "VDB-257462 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257462"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/addWifiMacFilter_deviceMac.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:56:35.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U addWifiMacFilter stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2711",
"datePublished": "2024-03-20T18:00:08.616Z",
"dateReserved": "2024-03-20T09:51:32.403Z",
"dateUpdated": "2024-08-21T22:56:23.392Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2710 (GCVE-0-2024-2710)
Vulnerability from nvd – Published: 2024-03-20 18:00 – Updated: 2024-08-21 22:59
VLAI?
Title
Tenda AC10U openSchedWifi setSchedWifi stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.443Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257461 | Tenda AC10U openSchedWifi setSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257461"
},
{
"name": "VDB-257461 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257461"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/setSchedWifi_start.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2710",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T19:06:25.531035Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T22:59:44.809Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC10U 15.03.06.49 wurde eine kritische Schwachstelle ausgemacht. Das betrifft die Funktion setSchedWifi der Datei /goform/openSchedWifi. Mittels Manipulieren des Arguments schedStartTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T18:00:07.175Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257461 | Tenda AC10U openSchedWifi setSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257461"
},
{
"name": "VDB-257461 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257461"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/setSchedWifi_start.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:56:20.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U openSchedWifi setSchedWifi stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2710",
"datePublished": "2024-03-20T18:00:07.175Z",
"dateReserved": "2024-03-20T09:51:17.589Z",
"dateUpdated": "2024-08-21T22:59:44.809Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2709 (GCVE-0-2024-2709)
Vulnerability from nvd – Published: 2024-03-20 17:31 – Updated: 2024-08-01 19:18
VLAI?
Title
Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2709",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-20T19:56:11.140465Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-30T15:13:58.664Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.324Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257460 | Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257460"
},
{
"name": "VDB-257460 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257460"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/fromSetRouteStatic.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.49 ausgemacht. Es betrifft die Funktion fromSetRouteStatic der Datei /goform/SetStaticRouteCfg. Mittels dem Manipulieren des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T17:31:05.924Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257460 | Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257460"
},
{
"name": "VDB-257460 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257460"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/fromSetRouteStatic.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:56:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2709",
"datePublished": "2024-03-20T17:31:05.924Z",
"dateReserved": "2024-03-20T09:51:03.150Z",
"dateUpdated": "2024-08-01T19:18:48.324Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2708 (GCVE-0-2024-2708)
Vulnerability from nvd – Published: 2024-03-20 17:31 – Updated: 2024-08-21 23:00
VLAI?
Title
Tenda AC10U execCommand formexeCommand stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.444Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257459 | Tenda AC10U execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257459"
},
{
"name": "VDB-257459 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257459"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formexeCommand.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2708",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-21T18:03:42.141392Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T23:00:05.639Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.49 gefunden. Hierbei geht es um die Funktion formexeCommand der Datei /goform/execCommand. Durch Manipulation des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T17:31:04.520Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257459 | Tenda AC10U execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257459"
},
{
"name": "VDB-257459 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257459"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formexeCommand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:55:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U execCommand formexeCommand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2708",
"datePublished": "2024-03-20T17:31:04.520Z",
"dateReserved": "2024-03-20T09:50:52.265Z",
"dateUpdated": "2024-08-21T23:00:05.639Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2707 (GCVE-0-2024-2707)
Vulnerability from nvd – Published: 2024-03-20 17:00 – Updated: 2024-08-21 23:00
VLAI?
Title
Tenda AC10U WriteFacMac formWriteFacMac os command injection
Summary
A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-78 - OS Command Injection
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.249Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257458 | Tenda AC10U WriteFacMac formWriteFacMac os command injection",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257458"
},
{
"name": "VDB-257458 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257458"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formWriteFacMac.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2707",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-20T19:32:27.465274Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T23:00:43.030Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC10U 15.03.06.49 wurde eine kritische Schwachstelle gefunden. Dabei geht es um die Funktion formWriteFacMac der Datei /goform/WriteFacMac. Durch die Manipulation des Arguments mac mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T17:00:07.795Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257458 | Tenda AC10U WriteFacMac formWriteFacMac os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257458"
},
{
"name": "VDB-257458 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257458"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formWriteFacMac.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:55:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U WriteFacMac formWriteFacMac os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2707",
"datePublished": "2024-03-20T17:00:07.795Z",
"dateReserved": "2024-03-20T09:50:27.154Z",
"dateUpdated": "2024-08-21T23:00:43.030Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2706 (GCVE-0-2024-2706)
Vulnerability from nvd – Published: 2024-03-20 16:31 – Updated: 2024-08-21 22:59
VLAI?
Title
Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.271Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257457 | Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257457"
},
{
"name": "VDB-257457 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257457"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formWifiWpsStart.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2706",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T19:02:04.566682Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T22:59:20.274Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.49 gefunden. Es geht dabei um die Funktion formWifiWpsStart der Datei /goform/WifiWpsStart. Mit der Manipulation des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T16:31:05.842Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257457 | Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257457"
},
{
"name": "VDB-257457 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257457"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formWifiWpsStart.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:55:14.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2706",
"datePublished": "2024-03-20T16:31:05.842Z",
"dateReserved": "2024-03-20T09:50:11.514Z",
"dateUpdated": "2024-08-21T22:59:20.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2705 (GCVE-0-2024-2705)
Vulnerability from nvd – Published: 2024-03-20 16:31 – Updated: 2024-08-01 19:18
VLAI?
Title
Tenda AC10U SetNetControlList formSetQosBand stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:ac10u:1.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2705",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-20T20:07:24.389193Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-18T20:06:01.280Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.341Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257456 | Tenda AC10U SetNetControlList formSetQosBand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257456"
},
{
"name": "VDB-257456 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257456"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetQosBand.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0"
},
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC10U 1.0/15.03.06.49 entdeckt. Es geht hierbei um die Funktion formSetQosBand der Datei /goform/SetNetControlList. Dank Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T16:31:04.186Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257456 | Tenda AC10U SetNetControlList formSetQosBand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257456"
},
{
"name": "VDB-257456 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257456"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetQosBand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:54:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U SetNetControlList formSetQosBand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2705",
"datePublished": "2024-03-20T16:31:04.186Z",
"dateReserved": "2024-03-20T09:49:55.324Z",
"dateUpdated": "2024-08-01T19:18:48.341Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-15218 (GCVE-0-2025-15218)
Vulnerability from cvelistv5 – Published: 2025-12-30 03:32 – Updated: 2025-12-30 15:37
VLAI?
Title
Tenda AC10U POST Request Parameter AdvSetLanip fromadvsetlanip buffer overflow
Summary
A weakness has been identified in Tenda AC10U 15.03.06.48/15.03.06.49. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Parameter Handler. Executing manipulation of the argument lanMask can lead to buffer overflow. The attack can be launched remotely. The exploit has been made available to the public and could be exploited.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
yhryhryhr_miemie (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-15218",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-30T15:37:49.540670Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T15:37:55.493Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"POST Request Parameter Handler"
],
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
},
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Tenda AC10U 15.03.06.48/15.03.06.49. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Parameter Handler. Executing manipulation of the argument lanMask can lead to buffer overflow. The attack can be launched remotely. The exploit has been made available to the public and could be exploited."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T03:32:08.254Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-338603 | Tenda AC10U POST Request Parameter AdvSetLanip fromadvsetlanip buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.338603"
},
{
"name": "VDB-338603 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.338603"
},
{
"name": "Submit #725461 | Tenda AC10U AC10U v1.0 Firmware V15.03.06.48\u3001AC10U v1.0 Firmware V15.03.06.49 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.725461"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC10U-fromadvsetlanip-2d753a41781f800c86c8d388a38e8101?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-12-28T16:44:13.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U POST Request Parameter AdvSetLanip fromadvsetlanip buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-15218",
"datePublished": "2025-12-30T03:32:08.254Z",
"dateReserved": "2025-12-28T15:39:08.350Z",
"dateUpdated": "2025-12-30T15:37:55.493Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-15215 (GCVE-0-2025-15215)
Vulnerability from cvelistv5 – Published: 2025-12-30 02:02 – Updated: 2025-12-30 18:46
VLAI?
Title
Tenda AC10U HTTP POST Request setPptpUserList formSetPPTPUserList buffer overflow
Summary
A vulnerability was determined in Tenda AC10U 15.03.06.48/15.03.06.49. This affects the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
yhryhryhr_miemie (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-15215",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-30T18:46:07.805035Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T18:46:13.307Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP POST Request Handler"
],
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
},
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda AC10U 15.03.06.48/15.03.06.49. This affects the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-30T02:02:08.414Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-338600 | Tenda AC10U HTTP POST Request setPptpUserList formSetPPTPUserList buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.338600"
},
{
"name": "VDB-338600 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.338600"
},
{
"name": "Submit #725365 | Tenda AC10U AC10U v1.0 Firmware V15.03.06.48\u3001AC10U v1.0 Firmware V15.03.06.49 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.725365"
},
{
"tags": [
"exploit"
],
"url": "https://www.notion.so/Tenda-AC10U-setPptpUserList-2d753a41781f80e8ba6bc37ba6100343?pvs=73"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-12-28T14:25:27.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U HTTP POST Request setPptpUserList formSetPPTPUserList buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-15215",
"datePublished": "2025-12-30T02:02:08.414Z",
"dateReserved": "2025-12-28T13:20:24.218Z",
"dateUpdated": "2025-12-30T18:46:13.307Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-10280 (GCVE-0-2024-10280)
Vulnerability from cvelistv5 – Published: 2024-10-23 13:31 – Updated: 2024-10-23 17:41
VLAI?
Title
Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
6.5 (Medium)
6.5 (Medium)
CWE
- CWE-476 - NULL Pointer Dereference
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
minipython (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac6_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.23"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac8_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.34.06"
}
]
},
{
"cpes": [
"cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac8_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.34.09"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.03.48.23"
},
{
"status": "affected",
"version": "16.03.48.19"
},
{
"status": "affected",
"version": "16.03.48.20"
},
{
"status": "affected",
"version": "16.03.48.13"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac1206_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.23"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac9_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.42"
},
{
"status": "affected",
"version": "15.03.05.19\\(6318_\\)"
},
{
"status": "affected",
"version": "15.03.05.14"
},
{
"status": "affected",
"version": "15.03.2.13"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19\\(6318\\)"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9\\(1307\\)"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.16"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.14"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac7_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac15_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.18"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac15_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.19"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10280",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T17:28:19.760214Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T17:41:57.370Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC6",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC8",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC15",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
},
{
"product": "AC1206",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241022"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "minipython (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T13:31:07.315Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.281555"
},
{
"name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.281555"
},
{
"name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.426417"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-10-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-10-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-10-23T08:07:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10280",
"datePublished": "2024-10-23T13:31:07.315Z",
"dateReserved": "2024-10-23T06:02:03.363Z",
"dateUpdated": "2024-10-23T17:41:57.370Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32306 (GCVE-0-2024-32306)
Vulnerability from cvelistv5 – Published: 2024-04-17 00:00 – Updated: 2024-08-02 02:06
VLAI?
Summary
Tenda AC10U v1.0 Firmware v15.03.06.49 has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
Severity ?
5.7 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49_multi_tde01"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-32306",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-22T19:47:47.493454Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:52:00.063Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:06:44.042Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/fromWizardHandle.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda AC10U v1.0 Firmware v15.03.06.49 has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T13:29:57.568081",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/fromWizardHandle.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-32306",
"datePublished": "2024-04-17T00:00:00",
"dateReserved": "2024-04-12T00:00:00",
"dateUpdated": "2024-08-02T02:06:44.042Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-30612 (GCVE-0-2024-30612)
Vulnerability from cvelistv5 – Published: 2024-03-28 00:00 – Updated: 2024-08-02 01:39
VLAI?
Summary
Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function.
Severity ?
8.1 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.48_multi_tde01:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tendacn",
"versions": [
{
"status": "affected",
"version": "15.03.06.48_multi_tde01"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-30612",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T16:00:40.817506Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T15:01:51.898Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:39:00.652Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetClientState.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-28T14:54:46.377312",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetClientState.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-30612",
"datePublished": "2024-03-28T00:00:00",
"dateReserved": "2024-03-27T00:00:00",
"dateUpdated": "2024-08-02T01:39:00.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2853 (GCVE-0-2024-2853)
Vulnerability from cvelistv5 – Published: 2024-03-24 05:00 – Updated: 2024-08-01 19:25
VLAI?
Title
Tenda AC10U setsambacfg formSetSambaConf os command injection
Summary
A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-78 - OS Command Injection
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
wxhwxhwxh_miemie (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
"cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.48_multi_tde01:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tendacn",
"versions": [
{
"status": "affected",
"version": "15.03.06.48_multi_tde01"
},
{
"status": "affected",
"version": "15.03.06.49_multi_tde01"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2853",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-25T14:19:55.063616Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T18:29:31.431Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:42.158Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257777 | Tenda AC10U setsambacfg formSetSambaConf os command injection",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257777"
},
{
"name": "VDB-257777 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257777"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
},
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC10U 15.03.06.48/15.03.06.49 ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formSetSambaConf der Datei /goform/setsambacfg. Durch die Manipulation des Arguments usbName mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-24T05:00:06.892Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257777 | Tenda AC10U setsambacfg formSetSambaConf os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257777"
},
{
"name": "VDB-257777 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257777"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetSambaConf.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-23T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-23T06:52:17.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U setsambacfg formSetSambaConf os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2853",
"datePublished": "2024-03-24T05:00:06.892Z",
"dateReserved": "2024-03-23T05:47:14.178Z",
"dateUpdated": "2024-08-01T19:25:42.158Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2764 (GCVE-0-2024-2764)
Vulnerability from cvelistv5 – Published: 2024-03-21 20:31 – Updated: 2024-08-02 13:57
VLAI?
Title
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_miemie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:41.687Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257601 | Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257601"
},
{
"name": "VDB-257601 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257601"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetPPTPServer.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.48_multi_tde01:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tendacn",
"versions": [
{
"status": "affected",
"version": "15.03.06.48_multi_tde01"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2764",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-22T14:41:42.917825Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-02T13:57:14.115Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.48 gefunden. Hiervon betroffen ist die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Durch die Manipulation des Arguments endIP mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-21T20:31:05.130Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257601 | Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257601"
},
{
"name": "VDB-257601 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257601"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetPPTPServer.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-21T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-21T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-21T16:22:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2764",
"datePublished": "2024-03-21T20:31:05.130Z",
"dateReserved": "2024-03-21T15:17:47.961Z",
"dateUpdated": "2024-08-02T13:57:14.115Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2763 (GCVE-0-2024-2763)
Vulnerability from cvelistv5 – Published: 2024-03-21 20:31 – Updated: 2024-08-01 19:25
VLAI?
Title
Tenda AC10U setcfm formSetCfm stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_miemie (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2763",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-22T17:49:42.492927Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T17:21:16.064Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:41.329Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257600 | Tenda AC10U setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257600"
},
{
"name": "VDB-257600 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257600"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetCfm.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.48 entdeckt. Davon betroffen ist die Funktion formSetCfm der Datei goform/setcfm. Mit der Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-21T20:31:03.792Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257600 | Tenda AC10U setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257600"
},
{
"name": "VDB-257600 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257600"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/formSetCfm.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-21T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-21T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-21T16:22:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2763",
"datePublished": "2024-03-21T20:31:03.792Z",
"dateReserved": "2024-03-21T15:17:45.636Z",
"dateUpdated": "2024-08-01T19:25:41.329Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2711 (GCVE-0-2024-2711)
Vulnerability from cvelistv5 – Published: 2024-03-20 18:00 – Updated: 2024-08-21 22:56
VLAI?
Title
Tenda AC10U addWifiMacFilter stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.437Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257462 | Tenda AC10U addWifiMacFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257462"
},
{
"name": "VDB-257462 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257462"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/addWifiMacFilter_deviceMac.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2711",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-20T19:33:40.489082Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T22:56:23.392Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.48"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.48 ausgemacht. Dies betrifft die Funktion addWifiMacFilter der Datei /goform/addWifiMacFilter. Durch das Manipulieren des Arguments deviceMac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T18:00:08.616Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257462 | Tenda AC10U addWifiMacFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257462"
},
{
"name": "VDB-257462 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257462"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.48/more/addWifiMacFilter_deviceMac.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:56:35.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U addWifiMacFilter stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2711",
"datePublished": "2024-03-20T18:00:08.616Z",
"dateReserved": "2024-03-20T09:51:32.403Z",
"dateUpdated": "2024-08-21T22:56:23.392Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2710 (GCVE-0-2024-2710)
Vulnerability from cvelistv5 – Published: 2024-03-20 18:00 – Updated: 2024-08-21 22:59
VLAI?
Title
Tenda AC10U openSchedWifi setSchedWifi stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.443Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257461 | Tenda AC10U openSchedWifi setSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257461"
},
{
"name": "VDB-257461 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257461"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/setSchedWifi_start.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2710",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T19:06:25.531035Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T22:59:44.809Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC10U 15.03.06.49 wurde eine kritische Schwachstelle ausgemacht. Das betrifft die Funktion setSchedWifi der Datei /goform/openSchedWifi. Mittels Manipulieren des Arguments schedStartTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T18:00:07.175Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257461 | Tenda AC10U openSchedWifi setSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257461"
},
{
"name": "VDB-257461 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257461"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/setSchedWifi_start.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:56:20.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U openSchedWifi setSchedWifi stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2710",
"datePublished": "2024-03-20T18:00:07.175Z",
"dateReserved": "2024-03-20T09:51:17.589Z",
"dateUpdated": "2024-08-21T22:59:44.809Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2709 (GCVE-0-2024-2709)
Vulnerability from cvelistv5 – Published: 2024-03-20 17:31 – Updated: 2024-08-01 19:18
VLAI?
Title
Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2709",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-20T19:56:11.140465Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-30T15:13:58.664Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.324Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257460 | Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257460"
},
{
"name": "VDB-257460 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257460"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/fromSetRouteStatic.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.49 ausgemacht. Es betrifft die Funktion fromSetRouteStatic der Datei /goform/SetStaticRouteCfg. Mittels dem Manipulieren des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T17:31:05.924Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257460 | Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257460"
},
{
"name": "VDB-257460 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257460"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/fromSetRouteStatic.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:56:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2709",
"datePublished": "2024-03-20T17:31:05.924Z",
"dateReserved": "2024-03-20T09:51:03.150Z",
"dateUpdated": "2024-08-01T19:18:48.324Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2708 (GCVE-0-2024-2708)
Vulnerability from cvelistv5 – Published: 2024-03-20 17:31 – Updated: 2024-08-21 23:00
VLAI?
Title
Tenda AC10U execCommand formexeCommand stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.444Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257459 | Tenda AC10U execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257459"
},
{
"name": "VDB-257459 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257459"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formexeCommand.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2708",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-21T18:03:42.141392Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T23:00:05.639Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.49 gefunden. Hierbei geht es um die Funktion formexeCommand der Datei /goform/execCommand. Durch Manipulation des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T17:31:04.520Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257459 | Tenda AC10U execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257459"
},
{
"name": "VDB-257459 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257459"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formexeCommand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:55:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U execCommand formexeCommand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2708",
"datePublished": "2024-03-20T17:31:04.520Z",
"dateReserved": "2024-03-20T09:50:52.265Z",
"dateUpdated": "2024-08-21T23:00:05.639Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2707 (GCVE-0-2024-2707)
Vulnerability from cvelistv5 – Published: 2024-03-20 17:00 – Updated: 2024-08-21 23:00
VLAI?
Title
Tenda AC10U WriteFacMac formWriteFacMac os command injection
Summary
A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-78 - OS Command Injection
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.249Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257458 | Tenda AC10U WriteFacMac formWriteFacMac os command injection",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257458"
},
{
"name": "VDB-257458 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257458"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formWriteFacMac.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2707",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-20T19:32:27.465274Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T23:00:43.030Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC10U 15.03.06.49 wurde eine kritische Schwachstelle gefunden. Dabei geht es um die Funktion formWriteFacMac der Datei /goform/WriteFacMac. Durch die Manipulation des Arguments mac mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T17:00:07.795Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257458 | Tenda AC10U WriteFacMac formWriteFacMac os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257458"
},
{
"name": "VDB-257458 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257458"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formWriteFacMac.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:55:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U WriteFacMac formWriteFacMac os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2707",
"datePublished": "2024-03-20T17:00:07.795Z",
"dateReserved": "2024-03-20T09:50:27.154Z",
"dateUpdated": "2024-08-21T23:00:43.030Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2706 (GCVE-0-2024-2706)
Vulnerability from cvelistv5 – Published: 2024-03-20 16:31 – Updated: 2024-08-21 22:59
VLAI?
Title
Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.271Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257457 | Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257457"
},
{
"name": "VDB-257457 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257457"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formWifiWpsStart.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2706",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T19:02:04.566682Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T22:59:20.274Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC10U 15.03.06.49 gefunden. Es geht dabei um die Funktion formWifiWpsStart der Datei /goform/WifiWpsStart. Mit der Manipulation des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T16:31:05.842Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257457 | Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257457"
},
{
"name": "VDB-257457 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257457"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formWifiWpsStart.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:55:14.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2706",
"datePublished": "2024-03-20T16:31:05.842Z",
"dateReserved": "2024-03-20T09:50:11.514Z",
"dateUpdated": "2024-08-21T22:59:20.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2705 (GCVE-0-2024-2705)
Vulnerability from cvelistv5 – Published: 2024-03-20 16:31 – Updated: 2024-08-01 19:18
VLAI?
Title
Tenda AC10U SetNetControlList formSetQosBand stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
yhryhryhr_mie (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:ac10u:1.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac10u_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2705",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-20T20:07:24.389193Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-18T20:06:01.280Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:18:48.341Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257456 | Tenda AC10U SetNetControlList formSetQosBand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257456"
},
{
"name": "VDB-257456 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257456"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetQosBand.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC10U",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0"
},
{
"status": "affected",
"version": "15.03.06.49"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC10U 1.0/15.03.06.49 entdeckt. Es geht hierbei um die Funktion formSetQosBand der Datei /goform/SetNetControlList. Dank Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-20T16:31:04.186Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257456 | Tenda AC10U SetNetControlList formSetQosBand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257456"
},
{
"name": "VDB-257456 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257456"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetQosBand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-20T10:54:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC10U SetNetControlList formSetQosBand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2705",
"datePublished": "2024-03-20T16:31:04.186Z",
"dateReserved": "2024-03-20T09:49:55.324Z",
"dateUpdated": "2024-08-01T19:18:48.341Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}