Search

Find a vulnerability

Search criteria

    372 vulnerabilities found for Teamcenter Visualization by Siemens

    CVE-2026-109619 (GCVE-0-2026-109619)

    Vulnerability from nvd – Published: 2026-10-21 13:54 – Updated: 2026-11-16 15:18
    VLAI CISA Shadowserver Previdian
    Title
    RCE via stale global state
    Summary
    PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE).
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-21 00:00 UTC
    CWE
    • CWE-416 - Use after free
    • CWE-755 - Improper Handling of Exceptional Conditions
    • CWE-824 - Access of uninitialized pointer
    • CWE-1325 - Improperly controlled sequential memory allocation
    • CWE-1419 - Incorrect Initialization of Resource
    Assigner
    php CNA under the mitre root
    CNA scorecard B 82/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    PHP Group PHP Affected: 8.2.* , < 8.2.35 (semver)
    Affected: 8.3.* , < 8.3.36 (semver)
    Affected: 8.4.* , < 8.4.27 (semver)
    Affected: 8.5.* , < 8.5.12 (semver)
    Create a notification for this product.
    Siemens AMIS TS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens AX4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX - S Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Building X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens CADRA Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Call stations Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Capital Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Chargesight Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Cloud IC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Devices Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect Insights Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X200 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X300 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X500 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens cRSP Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Depotfinity Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Essentials Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR2 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo Optic Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC5 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC7 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens DFMExpress Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V2.0SP9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V3.1SP1 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Management System Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted RTLS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted Space Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox H60 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Rapid Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Local Monitoring bt-monitoring-vm Affected: 0 , < V20261103 (custom)
    Create a notification for this product.
    Siemens Navigator E&S Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Unaffected: 0 , < * (custom)
    Create a notification for this product.

    50 of 110 products shown. All of them on the page of CVE-2026-109619.

    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-109619",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-21T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2026-10-26",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:47.838Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://www.wiz.io/blog/php2shell-php-rce"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://php2shell.delftintellab.com/"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2026-10-26T00:00:00.000Z",
                "value": "CVE-2026-109619 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-10-23T14:07:57.152Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/7"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/17"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/23"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/2"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/14"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/15"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/19"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/20"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/4"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "AMIS TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "AX4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX - S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Building X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "CADRA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Call stations",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Capital",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Chargesight",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Cloud IC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Devices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect Insights",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X200",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X300",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X500",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "cRSP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Depotfinity",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo Optic",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DFMExpress",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V2.0SP9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V3.1SP1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Management System",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted RTLS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted Space",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox H60",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Rapid",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Local Monitoring bt-monitoring-vm",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V20261103",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Navigator E\u0026S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PACE-Design",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard \u0026 Standard Plus",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Pathway to Learning Engineering",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Polarion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "QuadView",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D Configuration Backend",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flomaster",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flux",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Simlab",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sinteso FS20 EN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SiPass integrated",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPORT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Intrusion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Video",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power TG",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Supply Chain Suite",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Product Cost Management",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Share",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Visualization",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Tecnomatix Plant Simulation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TestWay",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Valor NPI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Verischarge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloudHeliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm panels",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm systems and audio matrices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Workplace Experience",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV676-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV776-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xcargo",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition IC Packaging",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Layout Browser",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-16T15:18:24.606Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "php-src",
              "product": "PHP",
              "vendor": "PHP Group",
              "versions": [
                {
                  "lessThan": "8.2.35",
                  "status": "affected",
                  "version": "8.2.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.3.36",
                  "status": "affected",
                  "version": "8.3.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.4.27",
                  "status": "affected",
                  "version": "8.4.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.5.12",
                  "status": "affected",
                  "version": "8.5.*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Wiz"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "Ryan at Calif.io"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "OpenAI"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Arnaud Le Blanc"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Ilija Tovilo"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Jakub Zelenka"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Nora Dossche"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
                }
              ],
              "value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-234",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-234 Hijacking a privileged process"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416 Use after free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755 Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824 Access of uninitialized pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1325",
                  "description": "CWE-1325 Improperly controlled sequential memory allocation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1419",
                  "description": "CWE-1419 Incorrect Initialization of Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T13:54:43.866Z",
            "orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
            "shortName": "php"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://github.com/php/php-src/security/advisories/GHSA-6wmf-4rv5-p3rp"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "RCE via stale global state",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Check the GitHub Security Advisory for mitigation strategies."
                }
              ],
              "value": "Check the GitHub Security Advisory for mitigation strategies."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
        "assignerShortName": "php",
        "cveId": "CVE-2026-109619",
        "datePublished": "2026-10-21T13:54:43.866Z",
        "dateReserved": "2026-10-12T21:04:00.504Z",
        "dateUpdated": "2026-11-16T15:18:24.606Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-109618 (GCVE-0-2026-109618)

    Vulnerability from nvd – Published: 2026-10-21 13:48 – Updated: 2026-11-16 15:18
    VLAI CISA Shadowserver Previdian
    Title
    RCE via OOM corruption
    Summary
    PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-21 00:00 UTC
    CWE
    • CWE-416 - Use after free
    • CWE-755 - Improper Handling of Exceptional Conditions
    • CWE-824 - Access of uninitialized pointer
    • CWE-1325 - Improperly controlled sequential memory allocation
    • CWE-1419 - Incorrect Initialization of Resource
    Assigner
    php CNA under the mitre root
    CNA scorecard B 82/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    PHP Group PHP Affected: 8.2.* , < 8.2.35 (semver)
    Affected: 8.3.* , < 8.3.36 (semver)
    Affected: 8.4.* , < 8.4.27 (semver)
    Affected: 8.5.* , < 8.5.12 (semver)
    Create a notification for this product.
    Siemens AMIS TS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens AX4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX - S Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Building X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens CADRA Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Call stations Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Capital Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Chargesight Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Cloud IC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Devices Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect Insights Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X200 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X300 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X500 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens cRSP Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Depotfinity Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Essentials Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR2 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo Optic Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC5 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC7 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens DFMExpress Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V2.0SP9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V3.1SP1 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Management System Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted RTLS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted Space Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox H60 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Rapid Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Local Monitoring bt-monitoring-vm Affected: 0 , < V20261103 (custom)
    Create a notification for this product.
    Siemens Navigator E&S Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Unaffected: 0 , < * (custom)
    Create a notification for this product.

    50 of 109 products shown. All of them on the page of CVE-2026-109618.

    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-109618",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-21T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2026-10-26",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:46.712Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://www.wiz.io/blog/php2shell-php-rce"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://php2shell.delftintellab.com"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2026-10-26T00:00:00.000Z",
                "value": "CVE-2026-109618 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-15T00:15:58.835Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/5"
              },
              {
                "url": "http://seclists.org/fulldisclosure/2026/Oct/51"
              },
              {
                "url": "https://github.com/rapid7/metasploit-framework/pull/22139"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "AMIS TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "AX4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX - S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Building X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "CADRA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Call stations",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Capital",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Chargesight",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Cloud IC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Devices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect Insights",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X200",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X300",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X500",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "cRSP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Depotfinity",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo Optic",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DFMExpress",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V2.0SP9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V3.1SP1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Management System",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted RTLS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted Space",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox H60",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Rapid",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Local Monitoring bt-monitoring-vm",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V20261103",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Navigator E\u0026S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PACE-Design",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard \u0026 Standard Plus",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Pathway to Learning Engineering",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Polarion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "QuadView",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D Configuration Backend",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flomaster",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flux",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Simlab",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sinteso FS20 EN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SiPass integrated",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPORT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Intrusion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Video",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power TG",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Supply Chain Suite",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Product Cost Management",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Share",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Visualization",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Tecnomatix Plant Simulation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TestWay",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Valor NPI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Verischarge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloudHeliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm panels",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm systems and audio matrices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Workplace Experience",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV676-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV776-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xcargo",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition IC Packaging",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Layout Browser",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-16T15:18:23.272Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "php-src",
              "product": "PHP",
              "vendor": "PHP Group",
              "versions": [
                {
                  "lessThan": "8.2.35",
                  "status": "affected",
                  "version": "8.2.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.3.36",
                  "status": "affected",
                  "version": "8.3.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.4.27",
                  "status": "affected",
                  "version": "8.4.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.5.12",
                  "status": "affected",
                  "version": "8.5.*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Ryan at Calif.io"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "Wiz"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Arnaud Le Blanc"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Ilija Tovilo"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Jakub Zelenka"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Nora Dossche"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).\u003cbr\u003e"
                }
              ],
              "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE)."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-234",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-234 Hijacking a privileged process"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416 Use after free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755 Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824 Access of uninitialized pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1325",
                  "description": "CWE-1325 Improperly controlled sequential memory allocation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1419",
                  "description": "CWE-1419 Incorrect Initialization of Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T13:48:34.845Z",
            "orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
            "shortName": "php"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "RCE via OOM corruption",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Check the GitHub Security Advisory for mitigation strategies."
                }
              ],
              "value": "Check the GitHub Security Advisory for mitigation strategies."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
        "assignerShortName": "php",
        "cveId": "CVE-2026-109618",
        "datePublished": "2026-10-21T13:48:34.845Z",
        "dateReserved": "2026-10-12T21:03:58.117Z",
        "dateUpdated": "2026-11-16T15:18:23.272Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-109619 (GCVE-0-2026-109619)

    Vulnerability from cvelistv5 – Published: 2026-10-21 13:54 – Updated: 2026-11-16 15:18
    VLAI CISA Shadowserver Previdian
    Title
    RCE via stale global state
    Summary
    PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE).
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-21 00:00 UTC
    CWE
    • CWE-416 - Use after free
    • CWE-755 - Improper Handling of Exceptional Conditions
    • CWE-824 - Access of uninitialized pointer
    • CWE-1325 - Improperly controlled sequential memory allocation
    • CWE-1419 - Incorrect Initialization of Resource
    Assigner
    php CNA under the mitre root
    CNA scorecard B 82/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    PHP Group PHP Affected: 8.2.* , < 8.2.35 (semver)
    Affected: 8.3.* , < 8.3.36 (semver)
    Affected: 8.4.* , < 8.4.27 (semver)
    Affected: 8.5.* , < 8.5.12 (semver)
    Create a notification for this product.
    Siemens AMIS TS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens AX4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX - S Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Building X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens CADRA Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Call stations Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Capital Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Chargesight Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Cloud IC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Devices Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect Insights Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X200 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X300 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X500 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens cRSP Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Depotfinity Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Essentials Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR2 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo Optic Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC5 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC7 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens DFMExpress Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V2.0SP9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V3.1SP1 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Management System Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted RTLS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted Space Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox H60 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Rapid Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Local Monitoring bt-monitoring-vm Affected: 0 , < V20261103 (custom)
    Create a notification for this product.
    Siemens Navigator E&S Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Unaffected: 0 , < * (custom)
    Create a notification for this product.

    50 of 110 products shown. All of them on the page of CVE-2026-109619.

    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-109619",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-21T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2026-10-26",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:47.838Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://www.wiz.io/blog/php2shell-php-rce"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109619"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://php2shell.delftintellab.com/"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2026-10-26T00:00:00.000Z",
                "value": "CVE-2026-109619 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-10-23T14:07:57.152Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/7"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/17"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/23"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/2"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/14"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/15"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/19"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/22/20"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/4"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "AMIS TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "AX4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX - S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Building X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "CADRA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Call stations",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Capital",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Chargesight",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Cloud IC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Devices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect Insights",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X200",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X300",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X500",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "cRSP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Depotfinity",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo Optic",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DFMExpress",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V2.0SP9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V3.1SP1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Management System",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted RTLS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted Space",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox H60",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Rapid",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Local Monitoring bt-monitoring-vm",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V20261103",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Navigator E\u0026S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PACE-Design",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard \u0026 Standard Plus",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Pathway to Learning Engineering",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Polarion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "QuadView",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D Configuration Backend",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flomaster",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flux",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Simlab",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sinteso FS20 EN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SiPass integrated",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPORT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Intrusion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Video",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power TG",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Supply Chain Suite",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Product Cost Management",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Share",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Visualization",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Tecnomatix Plant Simulation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TestWay",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Valor NPI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Verischarge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloudHeliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm panels",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm systems and audio matrices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Workplace Experience",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV676-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV776-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xcargo",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition IC Packaging",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Layout Browser",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-16T15:18:24.606Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "php-src",
              "product": "PHP",
              "vendor": "PHP Group",
              "versions": [
                {
                  "lessThan": "8.2.35",
                  "status": "affected",
                  "version": "8.2.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.3.36",
                  "status": "affected",
                  "version": "8.3.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.4.27",
                  "status": "affected",
                  "version": "8.4.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.5.12",
                  "status": "affected",
                  "version": "8.5.*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Wiz"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "Ryan at Calif.io"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "OpenAI"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Arnaud Le Blanc"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Ilija Tovilo"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Jakub Zelenka"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Nora Dossche"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
                }
              ],
              "value": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE)."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-234",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-234 Hijacking a privileged process"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416 Use after free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755 Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824 Access of uninitialized pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1325",
                  "description": "CWE-1325 Improperly controlled sequential memory allocation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1419",
                  "description": "CWE-1419 Incorrect Initialization of Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T13:54:43.866Z",
            "orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
            "shortName": "php"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://github.com/php/php-src/security/advisories/GHSA-6wmf-4rv5-p3rp"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "RCE via stale global state",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Check the GitHub Security Advisory for mitigation strategies."
                }
              ],
              "value": "Check the GitHub Security Advisory for mitigation strategies."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
        "assignerShortName": "php",
        "cveId": "CVE-2026-109619",
        "datePublished": "2026-10-21T13:54:43.866Z",
        "dateReserved": "2026-10-12T21:04:00.504Z",
        "dateUpdated": "2026-11-16T15:18:24.606Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-109618 (GCVE-0-2026-109618)

    Vulnerability from cvelistv5 – Published: 2026-10-21 13:48 – Updated: 2026-11-16 15:18
    VLAI CISA Shadowserver Previdian
    Title
    RCE via OOM corruption
    Summary
    PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-21 00:00 UTC
    CWE
    • CWE-416 - Use after free
    • CWE-755 - Improper Handling of Exceptional Conditions
    • CWE-824 - Access of uninitialized pointer
    • CWE-1325 - Improperly controlled sequential memory allocation
    • CWE-1419 - Incorrect Initialization of Resource
    Assigner
    php CNA under the mitre root
    CNA scorecard B 82/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    PHP Group PHP Affected: 8.2.* , < 8.2.35 (semver)
    Affected: 8.3.* , < 8.3.36 (semver)
    Affected: 8.4.* , < 8.4.27 (semver)
    Affected: 8.5.* , < 8.5.12 (semver)
    Create a notification for this product.
    Siemens AMIS TS Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens AX4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 360 NX3 M6 WM OD IISX - S Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Building X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens CADRA Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Call stations Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Capital Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Chargesight Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Cloud IC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Climatix Devices Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect Insights Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X200 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X300 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Connect X500 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens cRSP Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Depotfinity Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Designcenter X Essentials Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR2 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo DXR3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo Optic Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC3 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC4 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC5 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo PXC7 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens DFMExpress Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V2.0SP9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Engage V3.1SP1 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Energy Management System Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted RTLS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Enlighted Space Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox H60 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Rapid Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Local Monitoring bt-monitoring-vm Affected: 0 , < V20261103 (custom)
    Create a notification for this product.
    Siemens Navigator E&S Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Novigo VANSYS core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Unaffected: 0 , < * (custom)
    Create a notification for this product.

    50 of 109 products shown. All of them on the page of CVE-2026-109618.

    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-109618",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-21T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2026-10-26",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
                  },
                  "type": "kev"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:46.712Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://www.wiz.io/blog/php2shell-php-rce"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://arcticwolf.com/resources/blog/php2shell-critical-php-vulnerabilities-enable-unauthenticated-remote-code-execution/"
              },
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://php2shell.delftintellab.com"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-109618"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2026-10-26T00:00:00.000Z",
                "value": "CVE-2026-109618 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-15T00:15:58.835Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/21/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/5"
              },
              {
                "url": "http://seclists.org/fulldisclosure/2026/Oct/51"
              },
              {
                "url": "https://github.com/rapid7/metasploit-framework/pull/22139"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "AMIS TS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "AX4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 360 NX3 M6 WM OD IISX - S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Building X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "CADRA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Call stations",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Capital",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Chargesight",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Cloud IC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Climatix Devices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect Insights",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X200",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X300",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Connect X500",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "cRSP",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Depotfinity",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Designcenter X Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR2",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo DXR3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo Optic",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC3",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo PXC7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DFMExpress",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V2.0SP9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Engage V3.1SP1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Energy Management System",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted RTLS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Enlighted Space",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox H60",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Rapid",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Local Monitoring bt-monitoring-vm",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V20261103",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Navigator E\u0026S",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Novigo VANSYS core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PACE-Design",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard - XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Standard \u0026 Standard Plus",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Pathway to Learning Engineering",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Polarion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "QuadView",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sicharge D Configuration Backend",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flomaster",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Flux",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Simlab",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sinteso FS20 EN",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SiPass integrated",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPORT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Control Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Intrusion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Siveillance Video",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Solid Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 4",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power 7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Spectrum Power TG",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Supply Chain Suite",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Product Cost Management",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Share",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter Visualization",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Tecnomatix Plant Simulation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TestWay",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Valor NPI",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Verischarge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloudHeliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm panels",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Voice alarm systems and audio matrices",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Workplace Experience",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV676-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "WTV776-HB6035 Firmware",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xcargo",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise XCR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition IC Packaging",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Layout Browser",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-16T15:18:23.272Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-566435.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "php-src",
              "product": "PHP",
              "vendor": "PHP Group",
              "versions": [
                {
                  "lessThan": "8.2.35",
                  "status": "affected",
                  "version": "8.2.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.3.36",
                  "status": "affected",
                  "version": "8.3.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.4.27",
                  "status": "affected",
                  "version": "8.4.*",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.5.12",
                  "status": "affected",
                  "version": "8.5.*",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Ryan at Calif.io"
            },
            {
              "lang": "en",
              "type": "reporter",
              "value": "Wiz"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Arnaud Le Blanc"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Ilija Tovilo"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Jakub Zelenka"
            },
            {
              "lang": "en",
              "type": "remediation developer",
              "value": "Nora Dossche"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).\u003cbr\u003e"
                }
              ],
              "value": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE)."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-234",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-234 Hijacking a privileged process"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416 Use after free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-755",
                  "description": "CWE-755 Improper Handling of Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-824",
                  "description": "CWE-824 Access of uninitialized pointer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1325",
                  "description": "CWE-1325 Improperly controlled sequential memory allocation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-1419",
                  "description": "CWE-1419 Incorrect Initialization of Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-21T13:48:34.845Z",
            "orgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
            "shortName": "php"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://github.com/php/php-src/security/advisories/GHSA-w8hw-w9fx-j79w"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "RCE via OOM corruption",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Check the GitHub Security Advisory for mitigation strategies."
                }
              ],
              "value": "Check the GitHub Security Advisory for mitigation strategies."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "dd77f84a-d19a-4638-8c3d-a322d820ed2b",
        "assignerShortName": "php",
        "cveId": "CVE-2026-109618",
        "datePublished": "2026-10-21T13:48:34.845Z",
        "dateReserved": "2026-10-12T21:03:58.117Z",
        "dateUpdated": "2026-11-16T15:18:23.272Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    VAR-202412-0349

    Vulnerability from variot - Updated: 2025-10-04 22:00

    A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206). Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files in the wrltojt module. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production throughput and improve manufacturing system performance

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202412-0349",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3.0.12"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.2.0.14"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0016"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0005"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0008"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.2"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2302\u003cv2302.0016"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2404\u003cv2404.0005"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v14.2\u003cv14.2.0.14"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v14.3\u003cv14.3.0.12"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2312\u003cv2312.0008"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2406\u003cv2406.0005"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-058"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-00880"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028346"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53242"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Rocco Calvi (@TecR0c) with TecSecurity",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-058"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2024-53242",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "HIGH",
                "accessVector": "LOCAL",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 1.5,
                "id": "CNVD-2025-00880",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:L/AC:H/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2024-53242",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-028346",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2024-53242",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2024-53242",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-028346",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2024-53242",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-00880",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-058"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-00880"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028346"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53242"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0016), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. \r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206). Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files in the wrltojt module. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production throughput and improve manufacturing system performance",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-53242"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028346"
          },
          {
            "db": "ZDI",
            "id": "ZDI-25-058"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-00880"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-53242",
            "trust": 3.9
          },
          {
            "db": "SIEMENS",
            "id": "SSA-583523",
            "trust": 2.4
          },
          {
            "db": "SIEMENS",
            "id": "SSA-645131",
            "trust": 1.8
          },
          {
            "db": "JVN",
            "id": "JVNVU91750786",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-24-347-09",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028346",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-25206",
            "trust": 0.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-25-058",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-00880",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-058"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-00880"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028346"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53242"
          }
        ]
      },
      "id": "VAR-202412-0349",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-00880"
          }
        ],
        "trust": 0.8745396
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-00880"
          }
        ]
      },
      "last_update_date": "2025-10-04T22:00:02.482000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
          },
          {
            "title": "Patch for Siemens Teamcenter Visualization and Siemens Tecnomatix Plant Simulation Out-of-Bounds Read Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/650126"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-058"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-00880"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-125",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds read (CWE-125) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028346"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53242"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
          },
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91750786/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-53242"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-347-09"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-058"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-00880"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028346"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53242"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-25-058"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-00880"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028346"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53242"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-01-22T00:00:00",
            "db": "ZDI",
            "id": "ZDI-25-058"
          },
          {
            "date": "2025-01-10T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-00880"
          },
          {
            "date": "2025-10-03T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-028346"
          },
          {
            "date": "2024-12-10T14:30:46.700000",
            "db": "NVD",
            "id": "CVE-2024-53242"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-01-22T00:00:00",
            "db": "ZDI",
            "id": "ZDI-25-058"
          },
          {
            "date": "2025-01-10T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-00880"
          },
          {
            "date": "2025-10-03T04:48:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-028346"
          },
          {
            "date": "2025-09-24T19:40:30.147000",
            "db": "NVD",
            "id": "CVE-2024-53242"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Out-of-bounds read vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028346"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202412-0348

    Vulnerability from variot - Updated: 2025-10-03 21:58

    A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000). Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files in the wrltojt module. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume and improve manufacturing system performance

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202412-0348",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3.0.12"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.2.0.14"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0016"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0005"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0008"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.2"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2302\u003cv2302.0016"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2404\u003cv2404.0005"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v14.2\u003cv14.2.0.14"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v14.3\u003cv14.3.0.12"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2312\u003cv2312.0008"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2406\u003cv2406.0005"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-059"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-02597"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028258"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53041"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Rocco Calvi (@TecR0c) with TecSecurity",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-059"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2024-53041",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2025-02597",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2024-53041",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-028258",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2024-53041",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2024-53041",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-028258",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2024-53041",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-02597",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-059"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-02597"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028258"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53041"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0016), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files. \r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000). Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files in the wrltojt module. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume and improve manufacturing system performance",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-53041"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028258"
          },
          {
            "db": "ZDI",
            "id": "ZDI-25-059"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-02597"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-53041",
            "trust": 3.9
          },
          {
            "db": "SIEMENS",
            "id": "SSA-583523",
            "trust": 2.4
          },
          {
            "db": "SIEMENS",
            "id": "SSA-645131",
            "trust": 1.8
          },
          {
            "db": "JVN",
            "id": "JVNVU91750786",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-24-347-09",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028258",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-25000",
            "trust": 0.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-25-059",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-02597",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-059"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-02597"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028258"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53041"
          }
        ]
      },
      "id": "VAR-202412-0348",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-02597"
          }
        ],
        "trust": 0.8745396
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-02597"
          }
        ]
      },
      "last_update_date": "2025-10-03T21:58:30.428000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
          },
          {
            "title": "Patch for Siemens Teamcenter Visualization/Tecnomatix Plant Simulation Buffer Overflow Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/654596"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-059"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-02597"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028258"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53041"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
          },
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91750786/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-53041"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-347-09"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-25-059"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-02597"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028258"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53041"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-25-059"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-02597"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028258"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-53041"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-01-22T00:00:00",
            "db": "ZDI",
            "id": "ZDI-25-059"
          },
          {
            "date": "2025-02-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-02597"
          },
          {
            "date": "2025-09-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-028258"
          },
          {
            "date": "2024-12-10T14:30:46.507000",
            "db": "NVD",
            "id": "CVE-2024-53041"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-01-22T00:00:00",
            "db": "ZDI",
            "id": "ZDI-25-059"
          },
          {
            "date": "2025-02-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-02597"
          },
          {
            "date": "2025-09-30T08:18:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-028258"
          },
          {
            "date": "2025-09-24T19:40:50.583000",
            "db": "NVD",
            "id": "CVE-2024-53041"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Stack-based buffer overflow vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-028258"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0282

    Vulnerability from variot - Updated: 2025-10-03 21:40

    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process. Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0282",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0009"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3.0.13"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0021"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0010"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0002"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.0.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0007"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014756"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23396"
          }
        ]
      },
      "cve": "CVE-2025-23396",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-23396",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014756",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2025-23396",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014756",
                "trust": 0.8,
                "value": "High"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014756"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23396"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. \r\nThis could allow an attacker to execute code in the context of the current process. Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-23396"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014756"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-23396",
            "trust": 2.6
          },
          {
            "db": "SIEMENS",
            "id": "SSA-050438",
            "trust": 1.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-25-072-01",
            "trust": 0.8
          },
          {
            "db": "JVN",
            "id": "JVNVU92252869",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014756",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014756"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23396"
          }
        ]
      },
      "id": "VAR-202503-0282",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.2745396
      },
      "last_update_date": "2025-10-03T21:40:51.958000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014756"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23396"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu92252869/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-23396"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-01"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014756"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23396"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014756"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23396"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014756"
          },
          {
            "date": "2025-03-11T10:15:16.670000",
            "db": "NVD",
            "id": "CVE-2025-23396"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-30T08:48:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014756"
          },
          {
            "date": "2025-09-23T15:29:28.730000",
            "db": "NVD",
            "id": "CVE-2025-23396"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Out-of-bounds write vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014756"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0279

    Vulnerability from variot - Updated: 2025-10-03 21:35

    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a vulnerability related to the use of freed memory.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume, thereby improving manufacturing system performance

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0279",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0009"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3.0.13"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0021"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0010"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0002"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.0.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0007"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v14.3\u003c14.3.0.13"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2312\u003c2312.0009"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2406\u003c2406.0007"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2412\u003c2412.0002"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2302\u003c2302.0021"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2404\u003c2404.0010"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09523"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014754"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23402"
          }
        ]
      },
      "cve": "CVE-2025-23402",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2025-09523",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-23402",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014754",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2025-23402",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014754",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09523",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09523"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014754"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23402"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. \r\nAn attacker could leverage this vulnerability to execute code in the context of the current process. Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a vulnerability related to the use of freed memory.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume, thereby improving manufacturing system performance",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-23402"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014754"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09523"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-23402",
            "trust": 3.2
          },
          {
            "db": "SIEMENS",
            "id": "SSA-050438",
            "trust": 2.4
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-25-072-01",
            "trust": 0.8
          },
          {
            "db": "JVN",
            "id": "JVNVU92252869",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014754",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09523",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09523"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014754"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23402"
          }
        ]
      },
      "id": "VAR-202503-0279",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09523"
          }
        ],
        "trust": 0.8745396
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09523"
          }
        ]
      },
      "last_update_date": "2025-10-03T21:35:10.502000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Siemens Teamcenter Visualization and Siemens Tecnomatix Plant Simulation Resource Management Error Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/687611"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09523"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-416",
            "trust": 1.0
          },
          {
            "problemtype": "Use of freed memory (CWE-416) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014754"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23402"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu92252869/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-23402"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-01"
          },
          {
            "trust": 0.6,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.htmlhttps"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09523"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014754"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23402"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09523"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014754"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23402"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09523"
          },
          {
            "date": "2025-09-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014754"
          },
          {
            "date": "2025-03-11T10:15:17.680000",
            "db": "NVD",
            "id": "CVE-2025-23402"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09523"
          },
          {
            "date": "2025-09-30T08:48:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014754"
          },
          {
            "date": "2025-09-23T15:28:26.313000",
            "db": "NVD",
            "id": "CVE-2025-23402"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Vulnerability in using free memory in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014754"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0277

    Vulnerability from variot - Updated: 2025-10-03 21:00

    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0277",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0009"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0021"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3.0.13"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0010"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0002"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.0.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014895"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23401"
          }
        ]
      },
      "cve": "CVE-2025-23401",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-23401",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014895",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2025-23401",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014895",
                "trust": 0.8,
                "value": "High"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014895"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23401"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. \r\nThis could allow an attacker to execute code in the context of the current process. Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-23401"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014895"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-23401",
            "trust": 2.6
          },
          {
            "db": "SIEMENS",
            "id": "SSA-050438",
            "trust": 1.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-25-072-01",
            "trust": 0.8
          },
          {
            "db": "JVN",
            "id": "JVNVU92252869",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014895",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014895"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23401"
          }
        ]
      },
      "id": "VAR-202503-0277",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.2745396
      },
      "last_update_date": "2025-10-03T21:00:13.327000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-125",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds read (CWE-125) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014895"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23401"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu92252869/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-23401"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-01"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014895"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23401"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014895"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23401"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-02T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014895"
          },
          {
            "date": "2025-03-11T10:15:17.510000",
            "db": "NVD",
            "id": "CVE-2025-23401"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-02T02:01:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014895"
          },
          {
            "date": "2025-09-23T15:28:41.053000",
            "db": "NVD",
            "id": "CVE-2025-23401"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Out-of-bounds read vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014895"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0278

    Vulnerability from variot - Updated: 2025-10-03 20:04

    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a buffer error vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the functions of discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0278",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0009"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3.0.13"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0021"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0010"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0002"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.0.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0007"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v14.3\u003c14.3.0.13"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2312\u003c2312.0009"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2406\u003c2406.0007"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2412\u003c2412.0002"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2302\u003c2302.0021"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09959"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014755"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23398"
          }
        ]
      },
      "cve": "CVE-2025-23398",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2025-09959",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-23398",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014755",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2025-23398",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014755",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09959",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09959"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014755"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23398"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a buffer error vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the functions of discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-23398"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014755"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09959"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-23398",
            "trust": 3.2
          },
          {
            "db": "SIEMENS",
            "id": "SSA-050438",
            "trust": 2.4
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-25-072-01",
            "trust": 0.8
          },
          {
            "db": "JVN",
            "id": "JVNVU92252869",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014755",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09959",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09959"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014755"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23398"
          }
        ]
      },
      "id": "VAR-202503-0278",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09959"
          }
        ],
        "trust": 0.8745396
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09959"
          }
        ]
      },
      "last_update_date": "2025-10-03T20:04:41.484000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Siemens Teamcenter Visualization and Siemens Tecnomatix Plant Simulation buffer overflow vulnerability (CNVD-2025-09959)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/688246"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09959"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014755"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23398"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu92252869/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-23398"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-01"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09959"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014755"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23398"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09959"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014755"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23398"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09959"
          },
          {
            "date": "2025-09-30T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014755"
          },
          {
            "date": "2025-03-11T10:15:17.003000",
            "db": "NVD",
            "id": "CVE-2025-23398"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09959"
          },
          {
            "date": "2025-09-30T08:48:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014755"
          },
          {
            "date": "2025-09-23T15:29:08.563000",
            "db": "NVD",
            "id": "CVE-2025-23398"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Buffer error vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014755"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202505-1729

    Vulnerability from variot - Updated: 2025-10-03 19:44

    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202505-1729",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0010"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.008"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0013"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0004"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3.0.14"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014894"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-32454"
          }
        ]
      },
      "cve": "CVE-2025-32454",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-32454",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014894",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2025-32454",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014894",
                "trust": 0.8,
                "value": "High"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014894"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-32454"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.14), Teamcenter Visualization V2312 (All versions \u003c V2312.0010), Teamcenter Visualization V2406 (All versions \u003c V2406.0008), Teamcenter Visualization V2412 (All versions \u003c V2412.0004), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. \r\nThis could allow an attacker to execute code in the context of the current process. Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-32454"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014894"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-32454",
            "trust": 2.6
          },
          {
            "db": "SIEMENS",
            "id": "SSA-486186",
            "trust": 1.8
          },
          {
            "db": "SIEMENS",
            "id": "SSA-542540",
            "trust": 1.8
          },
          {
            "db": "JVN",
            "id": "JVNVU92528757",
            "trust": 0.8
          },
          {
            "db": "JVN",
            "id": "JVNVU96443907",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-25-162-01",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-25-135-06",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014894",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014894"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-32454"
          }
        ]
      },
      "id": "VAR-202505-1729",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.2745396
      },
      "last_update_date": "2025-10-03T19:44:45.827000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-125",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds read (CWE-125) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014894"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-32454"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-486186.html"
          },
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-542540.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu92528757/"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu96443907/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-32454"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-06"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-162-01"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014894"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-32454"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014894"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-32454"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-02T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014894"
          },
          {
            "date": "2025-05-13T10:15:24.953000",
            "db": "NVD",
            "id": "CVE-2025-32454"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-10-02T02:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014894"
          },
          {
            "date": "2025-09-23T15:26:08.277000",
            "db": "NVD",
            "id": "CVE-2025-32454"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Out-of-bounds read vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014894"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0284

    Vulnerability from variot - Updated: 2025-09-27 23:45

    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0284",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0009"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3.0.13"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0021"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0010"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0002"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0002"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0007"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014515"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-27438"
          }
        ]
      },
      "cve": "CVE-2025-27438",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-27438",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014515",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2025-27438",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014515",
                "trust": 0.8,
                "value": "High"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014515"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-27438"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. \r\nThis could allow an attacker to execute code in the context of the current process. Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-27438"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014515"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-27438",
            "trust": 2.6
          },
          {
            "db": "SIEMENS",
            "id": "SSA-050438",
            "trust": 1.8
          },
          {
            "db": "JVN",
            "id": "JVNVU92252869",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-25-072-01",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014515",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014515"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-27438"
          }
        ]
      },
      "id": "VAR-202503-0284",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.2745396
      },
      "last_update_date": "2025-09-27T23:45:37.899000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-125",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds read (CWE-125) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014515"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-27438"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu92252869/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-27438"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-01"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014515"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-27438"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014515"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-27438"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014515"
          },
          {
            "date": "2025-03-11T10:15:19.407000",
            "db": "NVD",
            "id": "CVE-2025-27438"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-26T06:29:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014515"
          },
          {
            "date": "2025-09-23T15:24:03.457000",
            "db": "NVD",
            "id": "CVE-2025-27438"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Out-of-bounds read vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014515"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0283

    Vulnerability from variot - Updated: 2025-09-27 20:11

    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a buffer error vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0283",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0009"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3.0.13"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0021"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0010"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0002"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.0.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0007"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v14.3\u003c14.3.0.13"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2312\u003c2312.0009"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2406\u003c2406.0007"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2412\u003c2412.0002"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2302\u003c2302.0021"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2404\u003c2404.0010"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014517"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23400"
          }
        ]
      },
      "cve": "CVE-2025-23400",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2025-09578",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-23400",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014517",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2025-23400",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014517",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09578",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014517"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23400"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a buffer error vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-23400"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014517"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09578"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-23400",
            "trust": 3.2
          },
          {
            "db": "SIEMENS",
            "id": "SSA-050438",
            "trust": 2.4
          },
          {
            "db": "JVN",
            "id": "JVNVU92252869",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-25-072-01",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014517",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09578",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014517"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23400"
          }
        ]
      },
      "id": "VAR-202503-0283",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09578"
          }
        ],
        "trust": 0.8745396
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09578"
          }
        ]
      },
      "last_update_date": "2025-09-27T20:11:01.791000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Siemens Teamcenter Visualization and Siemens Tecnomatix Plant Simulation Buffer Overflow Vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/687616"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09578"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014517"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23400"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu92252869/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-23400"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-01"
          },
          {
            "trust": 0.6,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.htmlhttps"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014517"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23400"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014517"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23400"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09578"
          },
          {
            "date": "2025-09-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014517"
          },
          {
            "date": "2025-03-11T10:15:17.340000",
            "db": "NVD",
            "id": "CVE-2025-23400"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09578"
          },
          {
            "date": "2025-09-26T06:30:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014517"
          },
          {
            "date": "2025-09-23T15:28:48.723000",
            "db": "NVD",
            "id": "CVE-2025-23400"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Buffer error vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014517"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0280

    Vulnerability from variot - Updated: 2025-09-25 20:52

    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0280",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0009"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3.0.13"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0021"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0010"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0002"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.0.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0007"
          },
          {
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014326"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23399"
          }
        ]
      },
      "cve": "CVE-2025-23399",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-23399",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014326",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2025-23399",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014326",
                "trust": 0.8,
                "value": "High"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014326"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23399"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. \r\nThis could allow an attacker to execute code in the context of the current process. Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-23399"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014326"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-23399",
            "trust": 2.6
          },
          {
            "db": "SIEMENS",
            "id": "SSA-050438",
            "trust": 1.8
          },
          {
            "db": "JVN",
            "id": "JVNVU92252869",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-25-072-01",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014326",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014326"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23399"
          }
        ]
      },
      "id": "VAR-202503-0280",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.2745396
      },
      "last_update_date": "2025-09-25T20:52:23.196000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-125",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds read (CWE-125) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014326"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23399"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu92252869/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-23399"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-01"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014326"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23399"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014326"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23399"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-24T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014326"
          },
          {
            "date": "2025-03-11T10:15:17.170000",
            "db": "NVD",
            "id": "CVE-2025-23399"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-09-24T05:56:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014326"
          },
          {
            "date": "2025-09-23T15:28:58.983000",
            "db": "NVD",
            "id": "CVE-2025-23399"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Out-of-bounds read vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014326"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202503-0281

    Vulnerability from variot - Updated: 2025-09-25 20:02

    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a buffer error vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume, thereby improving manufacturing system performance

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202503-0281",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0009"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2312.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.3.0.13"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2302.0021"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0010"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2404.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2412.0002"
          },
          {
            "model": "teamcenter visualization",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14.0.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2406.0007"
          },
          {
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v14.3\u003c14.3.0.13"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2312\u003c2312.0009"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2406\u003c2406.0007"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2412\u003c2412.0002"
          },
          {
            "model": "tecnomatix plant simulation",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2302\u003c2302.0021"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09960"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014327"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23397"
          }
        ]
      },
      "cve": "CVE-2025-23397",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2025-09960",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "productcert@siemens.com",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-23397",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2025-014327",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2025-23397",
                "trust": 1.0,
                "value": "High"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2025-014327",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-09960",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09960"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014327"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23397"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a buffer error vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume, thereby improving manufacturing system performance",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-23397"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014327"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09960"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-23397",
            "trust": 3.2
          },
          {
            "db": "SIEMENS",
            "id": "SSA-050438",
            "trust": 2.4
          },
          {
            "db": "JVN",
            "id": "JVNVU92252869",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-25-072-01",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014327",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-09960",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09960"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014327"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23397"
          }
        ]
      },
      "id": "VAR-202503-0281",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09960"
          }
        ],
        "trust": 0.8745396
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09960"
          }
        ]
      },
      "last_update_date": "2025-09-25T20:02:56.694000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Siemens Teamcenter Visualization Buffer Overflow Vulnerability (CNVD-2025-09960)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/688251"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09960"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "Buffer error (CWE-119) [ others ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014327"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23397"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu92252869/"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-23397"
          },
          {
            "trust": 0.8,
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-01"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09960"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014327"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23397"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-09960"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014327"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-23397"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09960"
          },
          {
            "date": "2025-09-24T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014327"
          },
          {
            "date": "2025-03-11T10:15:16.840000",
            "db": "NVD",
            "id": "CVE-2025-23397"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-09960"
          },
          {
            "date": "2025-09-24T05:56:00",
            "db": "JVNDB",
            "id": "JVNDB-2025-014327"
          },
          {
            "date": "2025-09-23T15:29:20.400000",
            "db": "NVD",
            "id": "CVE-2025-23397"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Buffer error vulnerability in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2025-014327"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-202101-0350

    Vulnerability from variot - Updated: 2024-11-23 21:31

    A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892). Several Siemens products are vulnerable to out-of-bounds writes. Zero Day Initiative To this vulnerability ZDI-CAN-11892 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,

    VFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "solid edge",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "se2021"
          },
          {
            "_id": null,
            "model": "solid edge",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "se2021"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "solid edge",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-050"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02582"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015271"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26989"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "rgod",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-050"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2020-26989",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2020-26989",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2021-02582",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-26989",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-26989",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-26989",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-26989",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-26989",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2020-26989",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-02582",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-848",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-050"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02582"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015271"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-848"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26989"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892). Several Siemens products are vulnerable to out-of-bounds writes. Zero Day Initiative To this vulnerability ZDI-CAN-11892 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,\r\n\r\nVFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-26989"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015271"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-050"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02582"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-26989",
            "trust": 3.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-050",
            "trust": 3.1
          },
          {
            "db": "SIEMENS",
            "id": "SSA-622830",
            "trust": 2.2
          },
          {
            "db": "SIEMENS",
            "id": "SSA-663999",
            "trust": 1.6
          },
          {
            "db": "SIEMENS",
            "id": "SSA-979834",
            "trust": 1.6
          },
          {
            "db": "JVN",
            "id": "JVNVU91685542",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015271",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11892",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02582",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0125",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0495",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-012-03",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-040-06",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-848",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-050"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02582"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015271"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-848"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26989"
          }
        ]
      },
      "id": "VAR-202101-0350",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02582"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "_id": null,
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02582"
          }
        ]
      },
      "last_update_date": "2024-11-23T21:31:23.872000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "SSA-979834",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "title": "Patch for JT2Go and Teamcenter Visualization heap buffer overflow vulnerability (CNVD-2021-02582)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/243982"
          },
          {
            "title": "Siemens Jt2go  and  Teamcenter Visualization Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139359"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-050"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02582"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015271"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-848"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015271"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26989"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.4,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-050/"
          },
          {
            "trust": 2.2,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "trust": 1.6,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
          },
          {
            "trust": 1.6,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26989"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91685542/"
          },
          {
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0495"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0125/"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-050"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02582"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015271"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-848"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26989"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-050",
            "ident": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02582",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015271",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-848",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26989",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-050",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02582",
            "ident": null
          },
          {
            "date": "2021-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015271",
            "ident": null
          },
          {
            "date": "2021-01-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-848",
            "ident": null
          },
          {
            "date": "2021-01-12T21:15:17.183000",
            "db": "NVD",
            "id": "CVE-2020-26989",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-050",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02582",
            "ident": null
          },
          {
            "date": "2021-09-15T08:33:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015271",
            "ident": null
          },
          {
            "date": "2021-07-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-848",
            "ident": null
          },
          {
            "date": "2024-11-21T05:20:38.207000",
            "db": "NVD",
            "id": "CVE-2020-26989",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-848"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "Out-of-bounds write vulnerabilities in multiple Siemens products",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015271"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "_id": null,
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-848"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-0349

    Vulnerability from variot - Updated: 2024-11-23 21:29

    A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11891). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-11891 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,

    VFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment.

    JT2Go and Teamcenter Visualization have security vulnerabilities

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-049"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015270"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26988"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "rgod",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-049"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2020-26988",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2020-26988",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2021-02583",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-26988",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-26988",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-26988",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-26988",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-26988",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2020-26988",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-02583",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-845",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-049"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015270"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-845"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26988"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0), Teamcenter Visualization (All versions \u003c V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11891). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-11891 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,\r\n\r\nVFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment. \n\r\n\r\nJT2Go and Teamcenter Visualization have security vulnerabilities",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-26988"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015270"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-049"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02583"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-26988",
            "trust": 3.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-049",
            "trust": 3.1
          },
          {
            "db": "SIEMENS",
            "id": "SSA-622830",
            "trust": 2.2
          },
          {
            "db": "JVN",
            "id": "JVNVU91685542",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015270",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11891",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02583",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0125",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-012-03",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-845",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-049"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015270"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-845"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26988"
          }
        ]
      },
      "id": "VAR-202101-0349",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02583"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "_id": null,
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02583"
          }
        ]
      },
      "last_update_date": "2024-11-23T21:29:48.209000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "SSA-622830",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "title": "Patch for Unspecified vulnerability exists in JT2Go and Teamcenter Visualization (CNVD-2021-02583)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/243985"
          },
          {
            "title": "Siemens Jt2go  and  Teamcenter Visualization Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139357"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-049"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015270"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-845"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015270"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26988"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.4,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-049/"
          },
          {
            "trust": 2.2,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26988"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91685542/"
          },
          {
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0125/"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-049"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015270"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-845"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26988"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-049",
            "ident": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02583",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015270",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-845",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26988",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-049",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02583",
            "ident": null
          },
          {
            "date": "2021-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015270",
            "ident": null
          },
          {
            "date": "2021-01-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-845",
            "ident": null
          },
          {
            "date": "2021-01-12T21:15:17.120000",
            "db": "NVD",
            "id": "CVE-2020-26988",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-049",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02583",
            "ident": null
          },
          {
            "date": "2021-09-15T08:33:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015270",
            "ident": null
          },
          {
            "date": "2021-02-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-845",
            "ident": null
          },
          {
            "date": "2024-11-21T05:20:38.093000",
            "db": "NVD",
            "id": "CVE-2020-26988",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-845"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds Vulnerability in Microsoft",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015270"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "_id": null,
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-845"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-0344

    Vulnerability from variot - Updated: 2024-11-23 21:22

    A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing PDF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11900). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-11900 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PDF files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,

    VFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment.

    JT2Go and Teamcenter Visualization has an unspecified vulnerability

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-054"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02588"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015265"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26983"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "rgod",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-054"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2020-26983",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2020-26983",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2021-02588",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-26983",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-26983",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-26983",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-26983",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-26983",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2020-26983",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-02588",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-852",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-054"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02588"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015265"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-852"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26983"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0), Teamcenter Visualization (All versions \u003c V13.1.0). Affected applications lack proper validation of user-supplied data when parsing PDF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11900). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-11900 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PDF files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,\r\n\r\nVFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment. \n\r\n\r\nJT2Go and Teamcenter Visualization has an unspecified vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-26983"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015265"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-054"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02588"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-26983",
            "trust": 3.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-054",
            "trust": 3.1
          },
          {
            "db": "SIEMENS",
            "id": "SSA-622830",
            "trust": 2.2
          },
          {
            "db": "JVN",
            "id": "JVNVU91685542",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015265",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11900",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02588",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0125",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-012-03",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-852",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-054"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02588"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015265"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-852"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26983"
          }
        ]
      },
      "id": "VAR-202101-0344",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02588"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "_id": null,
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02588"
          }
        ]
      },
      "last_update_date": "2024-11-23T21:22:00.173000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "SSA-622830",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "title": "Patch for Unspecified vulnerability exists in JT2Go and Teamcenter Visualization (CNVD-2021-02588)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/244000"
          },
          {
            "title": "Siemens Jt2go  and Siemens Teamcenter Visualization Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139363"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-054"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02588"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015265"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-852"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015265"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26983"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.4,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-054/"
          },
          {
            "trust": 2.2,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26983"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91685542/"
          },
          {
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0125/"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-054"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02588"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015265"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-852"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26983"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-054",
            "ident": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02588",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015265",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-852",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26983",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-054",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02588",
            "ident": null
          },
          {
            "date": "2021-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015265",
            "ident": null
          },
          {
            "date": "2021-01-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-852",
            "ident": null
          },
          {
            "date": "2021-01-12T21:15:16.823000",
            "db": "NVD",
            "id": "CVE-2020-26983",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-054",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02588",
            "ident": null
          },
          {
            "date": "2021-09-15T08:33:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015265",
            "ident": null
          },
          {
            "date": "2021-02-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-852",
            "ident": null
          },
          {
            "date": "2024-11-21T05:20:37.530000",
            "db": "NVD",
            "id": "CVE-2020-26983",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-852"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds Vulnerability in Microsoft",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015265"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "_id": null,
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-852"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-0354

    Vulnerability from variot - Updated: 2024-11-23 21:10

    A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing CGM files. This could lead to a stack based buffer overflow while trying to copy to a buffer in the font index handling function. An attacker could leverage this vulnerability to execute code in the context of the current process. JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT, VFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0354",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": "13.1.0"
          },
          {
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "jt2go",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015257"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26993"
          }
        ]
      },
      "cve": "CVE-2020-26993",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2020-26993",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2021-02578",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-26993",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-26993",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-26993",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-26993",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-02578",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-873",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015257"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-873"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26993"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0), Teamcenter Visualization (All versions \u003c V13.1.0). Affected applications lack proper validation of user-supplied data when parsing CGM files. This could lead to a stack based buffer overflow while trying to copy to a buffer in the font index handling function. An attacker could leverage this vulnerability to execute code in the context of the current process. JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT, VFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-26993"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015257"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02578"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-26993",
            "trust": 3.0
          },
          {
            "db": "SIEMENS",
            "id": "SSA-622830",
            "trust": 2.2
          },
          {
            "db": "JVN",
            "id": "JVNVU91685542",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015257",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02578",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-012-03",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0125",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-873",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015257"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-873"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26993"
          }
        ]
      },
      "id": "VAR-202101-0354",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02578"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02578"
          }
        ]
      },
      "last_update_date": "2024-11-23T21:10:16.580000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SSA-622830",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "title": "Patch for JT2Go and Teamcenter Visualization stack buffer overflow vulnerability (CNVD-2021-02578)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/243970"
          },
          {
            "title": "Siemens JTGo Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139374"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015257"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-873"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015257"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26993"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.2,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26993"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91685542/"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0125/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015257"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-873"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26993"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015257"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-873"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26993"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02578"
          },
          {
            "date": "2021-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015257"
          },
          {
            "date": "2021-01-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-873"
          },
          {
            "date": "2021-01-12T21:15:17.447000",
            "db": "NVD",
            "id": "CVE-2020-26993"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02578"
          },
          {
            "date": "2021-09-15T08:32:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015257"
          },
          {
            "date": "2021-02-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-873"
          },
          {
            "date": "2024-11-21T05:20:38.710000",
            "db": "NVD",
            "id": "CVE-2020-26993"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-873"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds Vulnerability in Microsoft",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015257"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-873"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-1897

    Vulnerability from variot - Updated: 2024-11-23 21:09

    An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory corruption vulnerability exists when reading malformed DGN files. It can allow attackers to cause a crash, potentially enabling denial of service (Crash, Exit, or Restart). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "drawings software development kit",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "opendesign",
            "version": "2021.12"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "comos",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "10.4.1"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "drawings sdk",
            "scope": null,
            "trust": 0.8,
            "vendor": "open design alliance",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-226"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002745"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25174"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "rgod",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-226"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2021-25174",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2021-25174",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "VHN-383903",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-25174",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-25174",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-25174",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-25174",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-25174",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2021-25174",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-1323",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-383903",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-226"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383903"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1323"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25174"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory corruption vulnerability exists when reading malformed DGN files. It can allow attackers to cause a crash, potentially enabling denial of service (Crash, Exit, or Restart). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DGN files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-25174"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002745"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-226"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383903"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-25174",
            "trust": 3.2
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-226",
            "trust": 3.2
          },
          {
            "db": "SIEMENS",
            "id": "SSA-155599",
            "trust": 1.7
          },
          {
            "db": "SIEMENS",
            "id": "SSA-663999",
            "trust": 1.7
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-047-01",
            "trust": 1.4
          },
          {
            "db": "JVN",
            "id": "JVNVU92291213",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002745",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-12026",
            "trust": 0.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1323",
            "trust": 0.7
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0577",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2022.1047",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-22-069-06",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-040-06",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2022031102",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-383903",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-226"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383903"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1323"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25174"
          }
        ]
      },
      "id": "VAR-202101-1897",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-383903"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-11-23T21:09:20.319000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "Vulnerabilities\u00a0in\u00a0the\u00a0ODA\u00a0Drawings\u00a0Software\u00a0Development\u00a0Kit Siemens Siemens\u00a0Security\u00a0Advisory",
            "trust": 0.8,
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "title": "Open Design Alliance Drawings SDK Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139579"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-226"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1323"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.1
          },
          {
            "problemtype": "Resource exhaustion (CWE-400) [NVD Evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-400",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-383903"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002745"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25174"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.5,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-226/"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25174"
          },
          {
            "trust": 1.4,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-047-01"
          },
          {
            "trust": 1.3,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "trust": 0.8,
            "url": "http://jvn.jp/vu/jvnvu92291213/index.html"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2022.1047"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0577"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2022031102"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-069-06"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-226"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383903"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1323"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25174"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-226",
            "ident": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-383903",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002745",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1323",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25174",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-226",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "VULHUB",
            "id": "VHN-383903",
            "ident": null
          },
          {
            "date": "2021-09-29T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-002745",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-1323",
            "ident": null
          },
          {
            "date": "2021-01-18T08:15:13.117000",
            "db": "NVD",
            "id": "CVE-2021-25174",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-226",
            "ident": null
          },
          {
            "date": "2022-04-08T00:00:00",
            "db": "VULHUB",
            "id": "VHN-383903",
            "ident": null
          },
          {
            "date": "2021-09-29T08:26:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-002745",
            "ident": null
          },
          {
            "date": "2022-04-11T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-1323",
            "ident": null
          },
          {
            "date": "2024-11-21T05:54:30.027000",
            "db": "NVD",
            "id": "CVE-2021-25174",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1323"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "Open\u00a0Design\u00a0Alliance\u00a0Drawings\u00a0SDK\u00a0 Resource Depletion Vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002745"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "_id": null,
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1323"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-0347

    Vulnerability from variot - Updated: 2024-11-23 21:05

    A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of JT files. This could lead to a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12014). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-12014 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of JT files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,

    VFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-057"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02585"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015268"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26986"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "rgod",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-057"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2020-26986",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2020-26986",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2021-02585",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-26986",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-26986",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-26986",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-26986",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-26986",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2020-26986",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-02585",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-850",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-057"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02585"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015268"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-850"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26986"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0), Teamcenter Visualization (All versions \u003c V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of JT files. This could lead to a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12014). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-12014 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of JT files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,\r\n\r\nVFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-26986"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015268"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-057"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02585"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-26986",
            "trust": 3.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-057",
            "trust": 3.1
          },
          {
            "db": "SIEMENS",
            "id": "SSA-622830",
            "trust": 2.2
          },
          {
            "db": "JVN",
            "id": "JVNVU91685542",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015268",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-12014",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02585",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0125",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-012-03",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-850",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-057"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02585"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015268"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-850"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26986"
          }
        ]
      },
      "id": "VAR-202101-0347",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02585"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "_id": null,
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02585"
          }
        ]
      },
      "last_update_date": "2024-11-23T21:05:14.135000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "SSA-622830",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "title": "Patch for JT2Go and Teamcenter Visualization heap buffer overflow vulnerability (CNVD-2021-02585)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/243991"
          },
          {
            "title": "Siemens Jt2go  and  Teamcenter Visualization Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139361"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-057"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02585"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015268"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-850"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-122",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015268"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26986"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.4,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-057/"
          },
          {
            "trust": 2.2,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26986"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91685542/"
          },
          {
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0125/"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-057"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02585"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015268"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-850"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26986"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-057",
            "ident": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02585",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015268",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-850",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26986",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-057",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02585",
            "ident": null
          },
          {
            "date": "2021-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015268",
            "ident": null
          },
          {
            "date": "2021-01-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-850",
            "ident": null
          },
          {
            "date": "2021-01-12T21:15:16.997000",
            "db": "NVD",
            "id": "CVE-2020-26986",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-057",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02585",
            "ident": null
          },
          {
            "date": "2021-09-15T08:33:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015268",
            "ident": null
          },
          {
            "date": "2021-02-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-850",
            "ident": null
          },
          {
            "date": "2024-11-21T05:20:37.863000",
            "db": "NVD",
            "id": "CVE-2020-26986",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-850"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds Vulnerability in Microsoft",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015268"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "_id": null,
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-850"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-0342

    Vulnerability from variot - Updated: 2024-11-23 21:02

    A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). When opening a specially crafted xml file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11890). JT2Go and Teamcenter Visualization Has XML An external entity vulnerability exists. Zero Day Initiative To this vulnerability ZDI-CAN-11890 Was numbered.Information may be obtained. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PLMXML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,

    VFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-048"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02590"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015263"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26981"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "rgod",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-048"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2020-26981",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2020-26981",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.6,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2021-02590",
                "impactScore": 7.8,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:N/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-26981",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-26981",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-26981",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-26981",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-26981",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "ZDI",
                "id": "CVE-2020-26981",
                "trust": 0.7,
                "value": "MEDIUM"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-02590",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-923",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-048"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02590"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015263"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-923"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26981"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0), Teamcenter Visualization (All versions \u003c V13.1.0). When opening a specially crafted xml file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11890). JT2Go and Teamcenter Visualization Has XML An external entity vulnerability exists. Zero Day Initiative To this vulnerability ZDI-CAN-11890 Was numbered.Information may be obtained. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PLMXML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,\r\n\r\nVFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-26981"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015263"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-048"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02590"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-26981",
            "trust": 3.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-048",
            "trust": 3.1
          },
          {
            "db": "SIEMENS",
            "id": "SSA-622830",
            "trust": 2.2
          },
          {
            "db": "JVN",
            "id": "JVNVU91685542",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015263",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11890",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02590",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0125",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-012-03",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-923",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-048"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02590"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015263"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-923"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26981"
          }
        ]
      },
      "id": "VAR-202101-0342",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02590"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "_id": null,
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02590"
          }
        ]
      },
      "last_update_date": "2024-11-23T21:02:57.121000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "SSA-622830",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "title": "Patch for JT2Go and Teamcenter VisualizationXML External Entity Reference Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/244006"
          },
          {
            "title": "Siemens Jt2go  and  Siemens Teamcenter Visualization Fixes for code issue vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=138851"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-048"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02590"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015263"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-923"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-611",
            "trust": 1.0
          },
          {
            "problemtype": "XML Improper restrictions on external entity references (CWE-611) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015263"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26981"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.4,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-048/"
          },
          {
            "trust": 2.2,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26981"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91685542/"
          },
          {
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0125/"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-048"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02590"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015263"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-923"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26981"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-048",
            "ident": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02590",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015263",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-923",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26981",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-048",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02590",
            "ident": null
          },
          {
            "date": "2021-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015263",
            "ident": null
          },
          {
            "date": "2021-01-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-923",
            "ident": null
          },
          {
            "date": "2021-01-12T21:15:16.683000",
            "db": "NVD",
            "id": "CVE-2020-26981",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-048",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02590",
            "ident": null
          },
          {
            "date": "2021-09-15T08:33:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015263",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-923",
            "ident": null
          },
          {
            "date": "2024-11-21T05:20:37.307000",
            "db": "NVD",
            "id": "CVE-2020-26981",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-923"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 In \u00a0XML\u00a0 External entity vulnerabilities",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015263"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "_id": null,
        "data": "code problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-923"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-0353

    Vulnerability from variot - Updated: 2024-11-23 20:49

    A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing CGM files. This could lead to a stack based buffer overflow while trying to copy to a buffer during font string handling. An attacker could leverage this vulnerability to execute code in the context of the current process. JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT, VFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0353",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": "13.1.0"
          },
          {
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "model": "jt2go",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          },
          {
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015256"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26992"
          }
        ]
      },
      "cve": "CVE-2020-26992",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2020-26992",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2021-02579",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-26992",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-26992",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-26992",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-26992",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-02579",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-843",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015256"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-843"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26992"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0), Teamcenter Visualization (All versions \u003c V13.1.0). Affected applications lack proper validation of user-supplied data when parsing CGM files. This could lead to a stack based buffer overflow while trying to copy to a buffer during font string handling. An attacker could leverage this vulnerability to execute code in the context of the current process. JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT, VFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-26992"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015256"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02579"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-26992",
            "trust": 3.0
          },
          {
            "db": "SIEMENS",
            "id": "SSA-622830",
            "trust": 2.2
          },
          {
            "db": "JVN",
            "id": "JVNVU91685542",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015256",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02579",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-012-03",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0125",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-843",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015256"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-843"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26992"
          }
        ]
      },
      "id": "VAR-202101-0353",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02579"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02579"
          }
        ]
      },
      "last_update_date": "2024-11-23T20:49:07.528000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SSA-622830",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "title": "Patch for JT2Go and Teamcenter Visualization stack buffer overflow vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/243973"
          },
          {
            "title": "Siemens JTGo Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139355"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015256"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-843"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-121",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015256"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26992"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.2,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26992"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91685542/"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0125/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015256"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-843"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26992"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015256"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-843"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26992"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02579"
          },
          {
            "date": "2021-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015256"
          },
          {
            "date": "2021-01-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-843"
          },
          {
            "date": "2021-01-12T21:15:17.387000",
            "db": "NVD",
            "id": "CVE-2020-26992"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02579"
          },
          {
            "date": "2021-09-15T08:31:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015256"
          },
          {
            "date": "2021-02-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-843"
          },
          {
            "date": "2024-11-21T05:20:38.580000",
            "db": "NVD",
            "id": "CVE-2020-26992"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-843"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds Vulnerability in Microsoft",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015256"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-843"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-0343

    Vulnerability from variot - Updated: 2024-11-23 20:48

    A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing CG4 and CGM files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11898). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-11898 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of CG4 and CGM files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,

    VFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment.

    JT2Go and Teamcenter Visualization has an unspecified vulnerability

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": "13.1.0"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-052"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02589"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015264"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26982"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "rgod",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-052"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2020-26982",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2020-26982",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2021-02589",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-26982",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-26982",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-26982",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-26982",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-26982",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2020-26982",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-02589",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-921",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-052"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02589"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015264"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-921"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26982"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0), Teamcenter Visualization (All versions \u003c V13.1.0). Affected applications lack proper validation of user-supplied data when parsing CG4 and CGM files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11898). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-11898 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of CG4 and CGM files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,\r\n\r\nVFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment. \n\r\n\r\nJT2Go and Teamcenter Visualization has an unspecified vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-26982"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015264"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-052"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02589"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-26982",
            "trust": 3.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-052",
            "trust": 3.1
          },
          {
            "db": "SIEMENS",
            "id": "SSA-622830",
            "trust": 2.2
          },
          {
            "db": "JVN",
            "id": "JVNVU91685542",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015264",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11898",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02589",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0125",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-012-03",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-921",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-052"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02589"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015264"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-921"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26982"
          }
        ]
      },
      "id": "VAR-202101-0343",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02589"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "_id": null,
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02589"
          }
        ]
      },
      "last_update_date": "2024-11-23T20:48:21.973000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "SSA-622830",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "title": "Patch for Unidentified vulnerabilities in JT2Go and Teamcenter Visualization",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/244003"
          },
          {
            "title": "Siemens Jt2go  and Siemens Teamcenter Visualization Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139396"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-052"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02589"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015264"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-921"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015264"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26982"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.4,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-052/"
          },
          {
            "trust": 2.2,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26982"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91685542/"
          },
          {
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0125/"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-052"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02589"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015264"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-921"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26982"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-052",
            "ident": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02589",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015264",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-921",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26982",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-052",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02589",
            "ident": null
          },
          {
            "date": "2021-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015264",
            "ident": null
          },
          {
            "date": "2021-01-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-921",
            "ident": null
          },
          {
            "date": "2021-01-12T21:15:16.747000",
            "db": "NVD",
            "id": "CVE-2020-26982",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-052",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02589",
            "ident": null
          },
          {
            "date": "2021-09-15T08:33:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015264",
            "ident": null
          },
          {
            "date": "2021-02-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-921",
            "ident": null
          },
          {
            "date": "2024-11-21T05:20:37.417000",
            "db": "NVD",
            "id": "CVE-2020-26982",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-921"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds Vulnerability in Microsoft",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015264"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "_id": null,
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-921"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-1900

    Vulnerability from variot - Updated: 2024-11-23 20:48

    An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Confusion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of a user-supplied value prior to dereferencing it as a pointer. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "drawings software development kit",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "opendesign",
            "version": "2021.11"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "comos",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "10.4.1"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "drawings sdk",
            "scope": null,
            "trust": 0.8,
            "vendor": "open design alliance",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-219"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002748"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25177"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "Michael DePlante (@izobashi) of Trend Micro\u0027s Zero Day Initiative",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-219"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2021-25177",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2021-25177",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "VHN-383906",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-25177",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-25177",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-25177",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-25177",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-25177",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2021-25177",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-1315",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-383906",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-219"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383906"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002748"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1315"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25177"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Confusion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of a user-supplied value prior to dereferencing it as a pointer. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-25177"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002748"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-219"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383906"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-25177",
            "trust": 3.2
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-219",
            "trust": 3.2
          },
          {
            "db": "SIEMENS",
            "id": "SSA-155599",
            "trust": 1.7
          },
          {
            "db": "SIEMENS",
            "id": "SSA-663999",
            "trust": 1.7
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-047-01",
            "trust": 1.4
          },
          {
            "db": "JVN",
            "id": "JVNVU92291213",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002748",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11927",
            "trust": 0.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1315",
            "trust": 0.7
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2022.1047",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0577",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2022031102",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-22-069-06",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-040-06",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-383906",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-219"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383906"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002748"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1315"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25177"
          }
        ]
      },
      "id": "VAR-202101-1900",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-383906"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-11-23T20:48:05.345000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "Vulnerabilities\u00a0in\u00a0the\u00a0ODA\u00a0Drawings\u00a0Software\u00a0Development\u00a0Kit Siemens Siemens\u00a0Security\u00a0Advisory",
            "trust": 0.8,
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "title": "Open Design Alliance Drawings SDK Fixes for code issue vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139574"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-219"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002748"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1315"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-843",
            "trust": 1.1
          },
          {
            "problemtype": "Wrong type (CWE-843) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-383906"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002748"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25177"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.5,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-219/"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25177"
          },
          {
            "trust": 1.4,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-047-01"
          },
          {
            "trust": 1.3,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "trust": 0.8,
            "url": "http://jvn.jp/vu/jvnvu92291213/index.html"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2022.1047"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0577"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2022031102"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-069-06"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-219"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383906"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002748"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1315"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25177"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-219",
            "ident": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-383906",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002748",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1315",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25177",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-219",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "VULHUB",
            "id": "VHN-383906",
            "ident": null
          },
          {
            "date": "2021-09-29T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-002748",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-1315",
            "ident": null
          },
          {
            "date": "2021-01-18T08:15:13.273000",
            "db": "NVD",
            "id": "CVE-2021-25177",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-219",
            "ident": null
          },
          {
            "date": "2022-04-08T00:00:00",
            "db": "VULHUB",
            "id": "VHN-383906",
            "ident": null
          },
          {
            "date": "2021-09-29T08:27:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-002748",
            "ident": null
          },
          {
            "date": "2022-03-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-1315",
            "ident": null
          },
          {
            "date": "2024-11-21T05:54:30.510000",
            "db": "NVD",
            "id": "CVE-2021-25177",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1315"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "Open\u00a0Design\u00a0Alliance\u00a0Drawings\u00a0SDK\u00a0 Vulnerability regarding mistyping in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002748"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "_id": null,
        "data": "code problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1315"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-1901

    Vulnerability from variot - Updated: 2024-11-23 20:40

    An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A stack-based buffer overflow vulnerability exists when the recover operation is run with malformed .DXF and .DWG files. This can allow attackers to cause a crash potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF and DWG files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 2.1,
            "vendor": "siemens",
            "version": null
          },
          {
            "_id": null,
            "model": "drawings software development kit",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "opendesign",
            "version": "2021.11"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "comos",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "10.4.1"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "drawings sdk",
            "scope": null,
            "trust": 0.8,
            "vendor": "open design alliance",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-243"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-240"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-220"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002749"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25178"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "Francis Provencher {PRL}",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-243"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-240"
          }
        ],
        "trust": 1.4
      },
      "cve": "CVE-2021-25178",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2021-25178",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "VHN-383907",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-25178",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.4,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-25178",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-25178",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-25178",
                "impactScore": 1.4,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "ZDI",
                "id": "CVE-2021-25178",
                "trust": 1.4,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-25178",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-25178",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2021-25178",
                "trust": 0.7,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-1314",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-383907",
                "trust": 0.1,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-25178",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-243"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-240"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-220"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383907"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25178"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002749"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1314"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25178"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A stack-based buffer overflow vulnerability exists when the recover operation is run with malformed .DXF and .DWG files. This can allow attackers to cause a crash potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF and DWG files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-25178"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002749"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-243"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-240"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-220"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383907"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25178"
          }
        ],
        "trust": 3.69
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-25178",
            "trust": 4.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-243",
            "trust": 3.3
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-240",
            "trust": 3.3
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-220",
            "trust": 3.3
          },
          {
            "db": "SIEMENS",
            "id": "SSA-663999",
            "trust": 1.8
          },
          {
            "db": "SIEMENS",
            "id": "SSA-155599",
            "trust": 1.7
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-047-01",
            "trust": 1.4
          },
          {
            "db": "JVN",
            "id": "JVNVU92291213",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002749",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-12166",
            "trust": 0.7
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-12165",
            "trust": 0.7
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11901",
            "trust": 0.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1314",
            "trust": 0.7
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2022.1047",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0577",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2022031102",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-22-069-06",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-040-06",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-383907",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25178",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-243"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-240"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-220"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383907"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25178"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002749"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1314"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25178"
          }
        ]
      },
      "id": "VAR-202101-1901",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-383907"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-11-23T20:40:42.378000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 2.1,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "title": "Vulnerabilities\u00a0in\u00a0the\u00a0ODA\u00a0Drawings\u00a0Software\u00a0Development\u00a0Kit Siemens Siemens\u00a0Security\u00a0Advisory",
            "trust": 0.8,
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "title": "Open Design Alliance Drawings SDK Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139573"
          },
          {
            "title": "Siemens Security Advisories: Siemens Security Advisory",
            "trust": 0.1,
            "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=1c3bdb36e22f42f5b9339f0ff806382c"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-243"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-240"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-220"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25178"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002749"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1314"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.1
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-383907"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002749"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25178"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "trust": 2.7,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-243/"
          },
          {
            "trust": 2.6,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-220/"
          },
          {
            "trust": 2.6,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-240/"
          },
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
          },
          {
            "trust": 1.8,
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25178"
          },
          {
            "trust": 1.4,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-047-01"
          },
          {
            "trust": 0.8,
            "url": "http://jvn.jp/vu/jvnvu92291213/index.html"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2022.1047"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0577"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2022031102"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-069-06"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/787.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-243"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-240"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-220"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383907"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25178"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002749"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1314"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25178"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-243",
            "ident": null
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-240",
            "ident": null
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-220",
            "ident": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-383907",
            "ident": null
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25178",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002749",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1314",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25178",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-243",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-240",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-220",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "VULHUB",
            "id": "VHN-383907",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-25178",
            "ident": null
          },
          {
            "date": "2021-09-29T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-002749",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-1314",
            "ident": null
          },
          {
            "date": "2021-01-18T08:15:13.337000",
            "db": "NVD",
            "id": "CVE-2021-25178",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-243",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-240",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-220",
            "ident": null
          },
          {
            "date": "2022-04-08T00:00:00",
            "db": "VULHUB",
            "id": "VHN-383907",
            "ident": null
          },
          {
            "date": "2021-03-04T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-25178",
            "ident": null
          },
          {
            "date": "2021-09-29T08:27:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-002749",
            "ident": null
          },
          {
            "date": "2022-03-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-1314",
            "ident": null
          },
          {
            "date": "2024-11-21T05:54:30.673000",
            "db": "NVD",
            "id": "CVE-2021-25178",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1314"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "Open\u00a0Design\u00a0Alliance\u00a0Drawings\u00a0SDK\u00a0 Out-of-bounds Vulnerability in Microsoft",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002749"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "_id": null,
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1314"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-1898

    Vulnerability from variot - Updated: 2024-11-23 20:27

    An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Conversion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Open Design Alliance Drawings SDK Exists in a vulnerability related to illegal type conversion.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of a user-supplied value prior to dereferencing it as a pointer. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 4.2,
            "vendor": "siemens",
            "version": null
          },
          {
            "_id": null,
            "model": "drawings software development kit",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "opendesign",
            "version": "2021.11"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "comos",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "10.4.1"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "drawings sdk",
            "scope": null,
            "trust": 0.8,
            "vendor": "open design alliance",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-246"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-245"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-244"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-224"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-223"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-218"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002746"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25175"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "Michael DePlante (@izobashi) of Trend Micro\u0027s Zero Day Initiative",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-246"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-245"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-244"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-218"
          }
        ],
        "trust": 2.8
      },
      "cve": "CVE-2021-25175",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2021-25175",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "VHN-383904",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-25175",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 4.2,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-25175",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-25175",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "ZDI",
                "id": "CVE-2021-25175",
                "trust": 4.2,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-25175",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-25175",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-1317",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-383904",
                "trust": 0.1,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-25175",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-246"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-245"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-244"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-224"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-223"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-218"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383904"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25175"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002746"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1317"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25175"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Conversion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Open Design Alliance Drawings SDK Exists in a vulnerability related to illegal type conversion.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of a user-supplied value prior to dereferencing it as a pointer. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-25175"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002746"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-246"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-245"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-244"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-224"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-223"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-218"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383904"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25175"
          }
        ],
        "trust": 5.58
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-25175",
            "trust": 6.8
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-246",
            "trust": 3.3
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-245",
            "trust": 3.3
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-244",
            "trust": 3.3
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-224",
            "trust": 3.3
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-223",
            "trust": 3.3
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-218",
            "trust": 3.3
          },
          {
            "db": "SIEMENS",
            "id": "SSA-155599",
            "trust": 1.8
          },
          {
            "db": "SIEMENS",
            "id": "SSA-663999",
            "trust": 1.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-047-01",
            "trust": 1.4
          },
          {
            "db": "JVN",
            "id": "JVNVU92291213",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002746",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11911",
            "trust": 0.7
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11910",
            "trust": 0.7
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11914",
            "trust": 0.7
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11988",
            "trust": 0.7
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11993",
            "trust": 0.7
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11912",
            "trust": 0.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1317",
            "trust": 0.7
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-22-069-06",
            "trust": 0.7
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2022.1047",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0577",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2022031102",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-040-06",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-383904",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25175",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-246"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-245"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-244"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-224"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-223"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-218"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383904"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25175"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002746"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1317"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25175"
          }
        ]
      },
      "id": "VAR-202101-1898",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-383904"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-11-23T20:27:40.022000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 4.2,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "title": "Vulnerabilities\u00a0in\u00a0the\u00a0ODA\u00a0Drawings\u00a0Software\u00a0Development\u00a0Kit Siemens Siemens\u00a0Security\u00a0Advisory",
            "trust": 0.8,
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "title": "Open Design Alliance Drawings SDK Fixes for code issue vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139576"
          },
          {
            "title": "Siemens Security Advisories: Siemens Security Advisory",
            "trust": 0.1,
            "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=dce38d2a1ec28e091a143e851596b2e8"
          },
          {
            "title": "Siemens Security Advisories: Siemens Security Advisory",
            "trust": 0.1,
            "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=1c3bdb36e22f42f5b9339f0ff806382c"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-246"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-245"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-244"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-224"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-223"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-218"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25175"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002746"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1317"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-704",
            "trust": 1.1
          },
          {
            "problemtype": "Illegal type conversion or cast (CWE-704) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-383904"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002746"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25175"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 4.8,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "trust": 2.7,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-223/"
          },
          {
            "trust": 2.6,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-218/"
          },
          {
            "trust": 2.6,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-224/"
          },
          {
            "trust": 2.6,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-244/"
          },
          {
            "trust": 2.6,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-245/"
          },
          {
            "trust": 2.6,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-246/"
          },
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
          },
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
          },
          {
            "trust": 1.8,
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25175"
          },
          {
            "trust": 1.4,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-047-01"
          },
          {
            "trust": 0.8,
            "url": "http://jvn.jp/vu/jvnvu92291213/index.html"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2022.1047"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0577"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2022031102"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-069-06"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/704.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-069-06"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-246"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-245"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-244"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-224"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-223"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-218"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383904"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25175"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002746"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1317"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25175"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-246",
            "ident": null
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-245",
            "ident": null
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-244",
            "ident": null
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-224",
            "ident": null
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-223",
            "ident": null
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-218",
            "ident": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-383904",
            "ident": null
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25175",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002746",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1317",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25175",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-246",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-245",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-244",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-224",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-223",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-218",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "VULHUB",
            "id": "VHN-383904",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-25175",
            "ident": null
          },
          {
            "date": "2021-09-29T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-002746",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-1317",
            "ident": null
          },
          {
            "date": "2021-01-18T08:15:13.180000",
            "db": "NVD",
            "id": "CVE-2021-25175",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-246",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-245",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-244",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-224",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-223",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-218",
            "ident": null
          },
          {
            "date": "2022-04-08T00:00:00",
            "db": "VULHUB",
            "id": "VHN-383904",
            "ident": null
          },
          {
            "date": "2022-04-08T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-25175",
            "ident": null
          },
          {
            "date": "2021-09-29T08:26:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-002746",
            "ident": null
          },
          {
            "date": "2022-03-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-1317",
            "ident": null
          },
          {
            "date": "2024-11-21T05:54:30.173000",
            "db": "NVD",
            "id": "CVE-2021-25175",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1317"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "Siemens JT2Go DXF File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-246"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-245"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-244"
          }
        ],
        "trust": 2.1
      },
      "type": {
        "_id": null,
        "data": "code problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1317"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-1899

    Vulnerability from variot - Updated: 2024-11-23 20:22

    An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Open Design Alliance Drawings SDK Has NULL A pointer dereference vulnerability exists.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of a user-supplied value prior to dereferencing it as a pointer. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "_id": null,
            "model": "drawings software development kit",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "opendesign",
            "version": "2021.11"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "comos",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "10.4.1"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "drawings sdk",
            "scope": null,
            "trust": 0.8,
            "vendor": "open design alliance",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-222"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-221"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002747"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25176"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "rgod",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-222"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2021-25176",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2021-25176",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "VHN-383905",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-25176",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.4,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2021-25176",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-25176",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "ZDI",
                "id": "CVE-2021-25176",
                "trust": 1.4,
                "value": "HIGH"
              },
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-25176",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-25176",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-1316",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-383905",
                "trust": 0.1,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-25176",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-222"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-221"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383905"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25176"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002747"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1316"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25176"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Open Design Alliance Drawings SDK Has NULL A pointer dereference vulnerability exists.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of a user-supplied value prior to dereferencing it as a pointer. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-25176"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002747"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-222"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-221"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383905"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25176"
          }
        ],
        "trust": 3.06
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-25176",
            "trust": 4.0
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-222",
            "trust": 3.3
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-221",
            "trust": 3.3
          },
          {
            "db": "SIEMENS",
            "id": "SSA-663999",
            "trust": 1.8
          },
          {
            "db": "SIEMENS",
            "id": "SSA-155599",
            "trust": 1.7
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-047-01",
            "trust": 1.4
          },
          {
            "db": "JVN",
            "id": "JVNVU92291213",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002747",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11989",
            "trust": 0.7
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11913",
            "trust": 0.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1316",
            "trust": 0.7
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2022.1047",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0577",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-040-06",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-22-069-06",
            "trust": 0.6
          },
          {
            "db": "CS-HELP",
            "id": "SB2022031102",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-383905",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25176",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-222"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-221"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383905"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25176"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002747"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1316"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25176"
          }
        ]
      },
      "id": "VAR-202101-1899",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-383905"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-11-23T20:22:22.687000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 1.4,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "title": "Vulnerabilities\u00a0in\u00a0the\u00a0ODA\u00a0Drawings\u00a0Software\u00a0Development\u00a0Kit Siemens Siemens\u00a0Security\u00a0Advisory",
            "trust": 0.8,
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "title": "Open Design Alliance Drawings SDK Fixes for code issue vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139575"
          },
          {
            "title": "Siemens Security Advisories: Siemens Security Advisory",
            "trust": 0.1,
            "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=1c3bdb36e22f42f5b9339f0ff806382c"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-222"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-221"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25176"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002747"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1316"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-476",
            "trust": 1.1
          },
          {
            "problemtype": "NULL Pointer dereference (CWE-476) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-383905"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002747"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25176"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.7,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-222/"
          },
          {
            "trust": 2.6,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-221/"
          },
          {
            "trust": 2.0,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "trust": 1.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
          },
          {
            "trust": 1.8,
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25176"
          },
          {
            "trust": 1.4,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-047-01"
          },
          {
            "trust": 0.8,
            "url": "http://jvn.jp/vu/jvnvu92291213/index.html"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2022.1047"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0577"
          },
          {
            "trust": 0.6,
            "url": "https://www.cybersecurity-help.cz/vdb/sb2022031102"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-069-06"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/476.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-222"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-221"
          },
          {
            "db": "VULHUB",
            "id": "VHN-383905"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25176"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002747"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1316"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25176"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-222",
            "ident": null
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-221",
            "ident": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-383905",
            "ident": null
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-25176",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-002747",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1316",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2021-25176",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-222",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-221",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "VULHUB",
            "id": "VHN-383905",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-25176",
            "ident": null
          },
          {
            "date": "2021-09-29T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-002747",
            "ident": null
          },
          {
            "date": "2021-01-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-1316",
            "ident": null
          },
          {
            "date": "2021-01-18T08:15:13.227000",
            "db": "NVD",
            "id": "CVE-2021-25176",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-222",
            "ident": null
          },
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-221",
            "ident": null
          },
          {
            "date": "2022-04-08T00:00:00",
            "db": "VULHUB",
            "id": "VHN-383905",
            "ident": null
          },
          {
            "date": "2021-03-04T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-25176",
            "ident": null
          },
          {
            "date": "2021-09-29T08:26:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-002747",
            "ident": null
          },
          {
            "date": "2022-03-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-1316",
            "ident": null
          },
          {
            "date": "2024-11-21T05:54:30.343000",
            "db": "NVD",
            "id": "CVE-2021-25176",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1316"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "Siemens JT2Go DXF File Parsing Untrusted Pointer Dereference Remote Code Execution Vulnerability",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-222"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-221"
          }
        ],
        "trust": 1.4
      },
      "type": {
        "_id": null,
        "data": "code problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-1316"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202101-0351

    Vulnerability from variot - Updated: 2024-11-23 20:16

    A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing ASM files. A crafted ASM file could trigger a type confusion condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11897). JT2Go and Teamcenter Visualization Exists in a mistyped vulnerability. Zero Day Initiative To this vulnerability ZDI-CAN-11897 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of ASM files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,

    VFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v13.1.0"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-055"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02581"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015254"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26990"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "rgod",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-055"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2020-26990",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2020-26990",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2021-02581",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-26990",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-26990",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-26990",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-26990",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-26990",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2020-26990",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-02581",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202101-847",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-055"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02581"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015254"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-847"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26990"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing ASM files. A crafted ASM file could trigger a type confusion condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11897). JT2Go and Teamcenter Visualization Exists in a mistyped vulnerability. Zero Day Initiative To this vulnerability ZDI-CAN-11897 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of ASM files. JT2Go is a 3D JT viewing tool that allows users to view JT, PDF, Solid Edge, PLM XML and existing JT,\r\n\r\nVFZ, CGM, TIF data. Teamcenter visualization software enables companies to enhance their product lifecycle management (PLM) environment. The software enables corporate users to access documents, 2D drawings and 3D models in a single environment",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-26990"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015254"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-055"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02581"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-26990",
            "trust": 3.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-055",
            "trust": 3.1
          },
          {
            "db": "SIEMENS",
            "id": "SSA-622830",
            "trust": 2.2
          },
          {
            "db": "SIEMENS",
            "id": "SSA-663999",
            "trust": 1.6
          },
          {
            "db": "JVN",
            "id": "JVNVU91685542",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015254",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-11897",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02581",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-040-06",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-012-03",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0125",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0495",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-847",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-055"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02581"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015254"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-847"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26990"
          }
        ]
      },
      "id": "VAR-202101-0351",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02581"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "_id": null,
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-02581"
          }
        ]
      },
      "last_update_date": "2024-11-23T20:16:35.387000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "SSA-622830 Siemens\u00a0Security\u00a0Advisory",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "title": "Patch for JT2Go and Teamcenter Visualization incompatible type access resource vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/243979"
          },
          {
            "title": "Siemens Jt2go  and Siemens Teamcenter Visualization Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=139358"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-055"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02581"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015254"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-847"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-843",
            "trust": 1.0
          },
          {
            "problemtype": "Wrong type (CWE-843) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015254"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26990"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.4,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-055/"
          },
          {
            "trust": 2.2,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
          },
          {
            "trust": 1.6,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26990"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91685542/"
          },
          {
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03/"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-03"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0495"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0125/"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-055"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02581"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015254"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-847"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26990"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-055",
            "ident": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-02581",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015254",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-847",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26990",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-055",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02581",
            "ident": null
          },
          {
            "date": "2021-09-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015254",
            "ident": null
          },
          {
            "date": "2021-01-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-847",
            "ident": null
          },
          {
            "date": "2021-01-12T21:15:17.260000",
            "db": "NVD",
            "id": "CVE-2020-26990",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-01-14T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-055",
            "ident": null
          },
          {
            "date": "2021-01-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-02581",
            "ident": null
          },
          {
            "date": "2021-09-15T08:31:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015254",
            "ident": null
          },
          {
            "date": "2021-05-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202101-847",
            "ident": null
          },
          {
            "date": "2024-11-21T05:20:38.333000",
            "db": "NVD",
            "id": "CVE-2020-26990",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-847"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Vulnerability regarding mistyping in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015254"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "_id": null,
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202101-847"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202102-0327

    Vulnerability from variot - Updated: 2024-11-23 20:13

    A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PCT files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12182). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-12182 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PCT files. The Tenda AC18 is a router from the Chinese company Tenda

    Show details on source website

    {
      "affected_products": {
        "_id": null,
        "data": [
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": null
          },
          {
            "_id": null,
            "model": "teamcenter visualization",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
            "version": "13.1.0.1"
          },
          {
            "_id": null,
            "model": "jt2go",
            "scope": null,
            "trust": 0.7,
            "vendor": "siemens",
            "version": null
          },
          {
            "_id": null,
            "model": "ac18",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "tenda",
            "version": "v15.03.05.05"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-232"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-75821"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015914"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27006"
          }
        ]
      },
      "credits": {
        "_id": null,
        "data": "Francis Provencher {PRL}",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-232"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2020-27006",
      "cvss": {
        "_id": null,
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.6,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-27006",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2022-75821",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-27006",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-27006",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "ZDI",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2020-27006",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 0.7,
                "userInteraction": "REQUIRED",
                "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-27006",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-27006",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "ZDI",
                "id": "CVE-2020-27006",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2022-75821",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202102-864",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-232"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-75821"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015914"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202102-864"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27006"
          }
        ]
      },
      "description": {
        "_id": null,
        "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PCT files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12182). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds write. Zero Day Initiative To this vulnerability ZDI-CAN-12182 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PCT files. The Tenda AC18 is a router from the Chinese company Tenda",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-27006"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015914"
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-232"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-75821"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "_id": null,
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-27006",
            "trust": 3.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-21-232",
            "trust": 3.1
          },
          {
            "db": "SIEMENS",
            "id": "SSA-663999",
            "trust": 1.6
          },
          {
            "db": "JVN",
            "id": "JVNVU91083521",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015914",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-12182",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-75821",
            "trust": 0.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-21-040-06",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2021.0495",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202102-864",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-232"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-75821"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015914"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202102-864"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27006"
          }
        ]
      },
      "id": "VAR-202102-0327",
      "iot": {
        "_id": null,
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-75821"
          }
        ],
        "trust": 1.00125
      },
      "iot_taxonomy": {
        "_id": null,
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-75821"
          }
        ]
      },
      "last_update_date": "2024-11-23T20:13:55.452000Z",
      "patch": {
        "_id": null,
        "data": [
          {
            "title": "SSA-663999",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
          },
          {
            "title": "Siemens has issued an update to correct this vulnerability.",
            "trust": 0.7,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "title": "JT2Go Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=141286"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-232"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015914"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202102-864"
          }
        ]
      },
      "problemtype_data": {
        "_id": null,
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015914"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27006"
          }
        ]
      },
      "references": {
        "_id": null,
        "data": [
          {
            "trust": 2.4,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-21-232/"
          },
          {
            "trust": 1.6,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27006"
          },
          {
            "trust": 1.3,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu91083521/"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2021.0495"
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-21-232"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-75821"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015914"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202102-864"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27006"
          }
        ]
      },
      "sources": {
        "_id": null,
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-21-232",
            "ident": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-75821",
            "ident": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015914",
            "ident": null
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202102-864",
            "ident": null
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27006",
            "ident": null
          }
        ]
      },
      "sources_release_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-232",
            "ident": null
          },
          {
            "date": "2022-11-10T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-75821",
            "ident": null
          },
          {
            "date": "2021-10-22T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015914",
            "ident": null
          },
          {
            "date": "2021-02-09T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202102-864",
            "ident": null
          },
          {
            "date": "2021-02-09T17:15:14.343000",
            "db": "NVD",
            "id": "CVE-2020-27006",
            "ident": null
          }
        ]
      },
      "sources_update_date": {
        "_id": null,
        "data": [
          {
            "date": "2021-02-24T00:00:00",
            "db": "ZDI",
            "id": "ZDI-21-232",
            "ident": null
          },
          {
            "date": "2022-11-10T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-75821",
            "ident": null
          },
          {
            "date": "2021-10-22T08:12:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015914",
            "ident": null
          },
          {
            "date": "2021-10-19T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202102-864",
            "ident": null
          },
          {
            "date": "2024-11-21T05:20:40.170000",
            "db": "NVD",
            "id": "CVE-2020-27006",
            "ident": null
          }
        ]
      },
      "threat_type": {
        "_id": null,
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202102-864"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "_id": null,
        "data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds Vulnerability in Microsoft",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015914"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "_id": null,
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202102-864"
          }
        ],
        "trust": 0.6
      }
    }